2. In 2011 the Group of companies "ABIight" consolidated a number of enterprises
with the view of performing a complex of ac vi es rela ng to implementa on of
LED and emergency ligh ng projects.
Now the Group of companies carries out the totality of services rela ng to project
engineering, manufacturing, installa on and start-up opera ons of LED ligh ng
systems, as well as produc on of such emergency ligh ng units as EL, ELG, “Light
Balloon Tower”, MLU-2000 “Walli”, MLU-95 “Giraffe”, “Light Tower”.
The Group of companies consolidates:
Limited Liability Company
Research and Produc on Enterprise
"EnergoTechService"
- development of designs and projects for LED ligh ng systems,
- development of feasibility studies,
- produc on of LED lights and emergency ligh ng equipment,
- moun ng and start-up of power equipment,
- complete overhaul of high-voltage equipment.
Limited Liability Company Trading House "Energy - Technologies of Saving"
An exclusive distributor of all the products turned out.
Limited Liability Company "SVETOLAB"
- carries out spectrophotometric measurements
in a ligh ng laboratory.
Limited Liability Company Private Security Agency "Grid"
- guarding of industrial facili es;
- cargo escor ng;
- physical security.
Mobile Ligh ng Unit is designed for illumina on of industrial and
produc on spaces, construc on sites and disaster areas or for illumina on
while carrying out railroad reconstruc on, reclama on works, during road
building ac vi es, as well as in case of unauthorized power cut.
There are two types of Mobile Ligh ng Unit – MLU-95 “Giraffe” and
MLU-2000 “Walli”.
01
Lighting Unit
MLU-95 «Giraffe»
“Giraffe” is equipped with four 95V LED lamps with ver cal rota on
capacity. It has wheels both for overland and railway travel. With the help
of a hydraulic pump the moving unit body with LED lamps can be
extended to the height of up to 4.5 meters that allows to illuminate 80
metersineithersides.
LightingUnit
3. We introduce portable lighting units ETSN120L-R, ETSN120LB-R and
ETSN2400L-R designed for illumination of industrial sites or while carrying
out emergency works, road reconstruction or road building activities. They
can be used in case of power cut as this lighting unit is equipped with
a generator. Portable lighting unit has a sturdy body frame. It is portable and
easy to operate. The unit has double-sided LED lamps fixed on the rod that
provide double-sided illumination of 1080 Lm. The unit can be operated
with a remote control. LED lamp has swivel point for 60º downwards tilt.
Gentle and pleasing to the eye light allows to carry out operations near
by the unit. The unit can be charged from the car cigarette lighter. It can
be also equipped with a solar battery that is easy to carry in a special case.
Portable lighting unit is made of ultraviolet-resistant material. It's water-
proofandhasIP-65protectionlevel.
02
Lighting Unit
ETS N, M «Smith»
LightingUnit
03
LightingUnit
4. ELGm-150 “Light Tower” is used for area illumination during such weekend
activities as fishing, hunting or other open-air leisure time events. This
portable light tower may be used in case of power cut or for energy saving
purposes.
ELGm-150 “Light Tower” is made of a special air- and waterproof light
diffusing fabric with light source at the cylinder top. Upon switching the
cylinder blows up and lifts the light source to the height that allows to
illuminate the area of 1800 m². Compact size of retracted ELGm-150 “Light
Tower”makesitsuitableforcartrunktransportation.
Sodium lamp with 150W maximum output is used as a light source. Fabric
cylinder extended height is 2 meters. The cylinder is blown up by a fan
that works either from built-in power sta on or 220W power network
or if there is a DC/AC converter from 12V vehicle power supply. Thus,
under field condi ons and in complete darkness “Light Tower” allows to
illuminate area of 1800 m² in less than one minute. “Light Tower” steadily
illuminates the area with gentle light that is pleasing to the eye.
Shipping dimensions 40x35x40 cm
2
04
Lighting Unit
Light Tower
LightingUnit
Extended height –
up to 2 meters
Power is supplied either from 220W AC network or built-in
petrol generator (with 4 liter fuel tank = 6 hours of con nuous
work)
Blow-up me – up to 60 seconds
Lamp life cycle – 18 000 hours
Gross weight – up to 20 kg
Opera ng life – not less than 5 years.
Light source – 150 W sodium lamp. Luminous flux – 15000 Lm
Pump with 250W power capacity
Petrol generator HHY 960A
550W electrical output
Clima c category – C, Loca on category 1 (used outdoors) under GOST
15150
Ingress protec on - IP 65/44
Electric shock protec on class – I or II
Light distribu on - R class (sca ered light) under GOST 17677
Symbols explana ons - ELGm-150 – mini tower with power generator
and 150W sodium lamp, Technical Standard-8043-109-082-2004.
05
LightingUnit
5. “Walli” is equipped with a generator, four 500W metal halide lamps with
ver cal and horizontal rota on capacity. Due to the wheels it can be moved
by one person. Adjustable side supports allow to install MLU-2000 “Walli”
onanunevensurface.Thelampsfixedonthetelescopicmastareli edtothe
height of up to 3,5 meters by a pneuma c pump. Illumina on level
is70metersineithersides.
06
Lighting Unit
MLU-2000 “Walli”
LightingUnit
07
Emergency Lighting Unit
Light Balloon Tower
EmergencyLightingEquipment
The unit is widely used during all kinds of road and construc on works,
during natural disasters, at recovery efforts, can be set on specialized
vehicles on a special framework with or without a telescopic tube.
It can be used during improvement of thoroughfares, during various
fes ve, cultural and spor ng events and exhibi ons.
Specification
Power supply single-phase alterna ng current network
of 220 V,50 Hz, two-phase alterna ng current network
of 380 V, 50 Hz, or from an isolated genera on plant
Light source a gas-discharge high-pressure lamp: sodium arc lamp
DNaT (index S), DNaZ (H), mercury arc lamp DRI
(M),up to 2000 W
Luminous flux 48000 -180000 Lm
Protec on Level the plant requires connec on through RCD with
rated current of 16A (leakage current: 10-30 mA)
Illumina on level
Start-control devices
up to 12 000 sq. m for alterna ng current, voltage
of 220/380 V power up to 2000 W
(depending on the chosen wa age of the light source)
Shipping
dimensions
a lampshade in a protec ve cover 1250x300 mm,
start-control devices with a set of cables of 400 x 400 x
200 mm (dimensions may vary depending on the
chosen type of the start-control device)
Extended unit
height
up to 5,5m, diameter of the sphere – 0,9m
Gross weight up to 50 kg
The weight may vary depending on the complete set
Ligh ng unit
deployment me
1-2 minutes, me of complete ligh ng-up of the lamp
— 5 min, reclosure of the lamp is recommended a er
15 - 20 min, me of con nuous work is not standardized
Wind resistance
(with guy lines)
up to 25 m/sec
Clima c category U (temperate climate)
Placement category 1 under GOST 15150-69
Protec on level IP 44/65
Electric shock
protec on class
II
Light distribu on Class R under GOST 17677
Opera ng life not less than 5 years
Symbols explana on ELH-1 UMBRELLA 220/600 S - 220 V ligh ng unit,
mains-operated with a 600 W sodium lamp
6. The Emergency ligh ng unit is designed for urgent deployment on the site
in case of man-made and natural disasters, in case of unauthorized power
cut, for illumina on of great areas during mass events, as well as while
carrying out manufacturing or construc on night works in hard-to-reach
areas where high-priced equipment and skilled personnel are not available.
Unit cylinder is blown up by the fan that works either from built-in power
sta onor220Wpowernetwork.Itcanbeoperatedbyoneperson.
Mobile ligh ng units are mobile and suitable for car trunk
transporta on;
In complete darkness emergency ligh ng unit allows to illuminate the
area of 15 000 m² in less than three minutes. Fabric cylinder extracted
height is 3-5-7 meters.
08
2м
Emergency
Lighting Unit
EmergencyLightingEquipment
09
7м
5м
3м
EmergencyLightingEquipment
Specification
Power supply 220 V alterna ng current network,50 Hz, or from an
isolated genera on plant (see specifica on details
in the technical passport)
Light source a gas-discharge high-pressure lamp: sodium arc lamp
DNaT (index S), DNaZ (H), mercury arc lamp DRI (M),
150-1000 W
Luminous flux 48000 -120000 Lm. Op on of installing two or more
lamps is available
Illumina on level up to 15 000 m²
Light source power : from 150 to 1200 W, efficiency: 2,5 - 3,5 cub.
m/min, excess pressure: 10000 - 14000 Pa
Dimensions 600x450x500 mm.
(Dimensions may vary depending on the chosen type of the unit)
Extended unit height 2m, 3-5 and 5-7 m
Gross weight up to 26 kg
(with a built-in power sta on - up to 65 kg). The weight may vary
depending on the complete set
Ligh ng unit
deployment me
1 minute, me of complete ligh ng-up of the lamp —
5 min, reclosure of the lamp is recommended a er
15 - 20 min
Wind resistance
(with guy lines)
up to 25 m/sec
Clima c category U (temperate climate)
Placement category 1 under GOST 15150-69
Protec on level IP 44/65
Electric shock
protec on class
II
Light distribu on Class R under GOST 17677
Opera ng life not less than 5 years
7. 10
IndustrialLighting
LED light
ETSLD'12, ETSLD'18
The LED light is designed for even ligh ng of small workrooms, illumina on of worksites, small open areas,
railway lines, pla orms, pedestrian crossings, etc.
It can also be used for architectural illumina on of buildings.
Opera ng me
100 000 hours
with light decay not more than 30%
Specification
Supply voltage, V
Rated frequency, Hz
Protec on class under GOST 14254-96
Clima c category under GOST 15150-69
Electric shock protec on class
Rated power consump on, W
Colour temperature, К
Weight, kg
Light luminous flux, Lm
LED luminous flux, Lm
from 165 to 265
50-60
IP 67
UHL 1
1
15.7
5700-6500
2.4
1200
1600
Specification
Supply voltage, V
Rated frequency, Hz
Protec on class under GOST 14254-96
Clima c category under GOST 15150-69
Electric shock protec on class
Rated power consump on, W
Colour temperature, К
Weight, kg
Light luminous flux, Lm
LED luminous flux, Lm
from 165 to 265
50-60
IP 67
UHL 1
1
23.5
5700-6500
2.7
1700
2300
To avoid inaccuracies in selec ng product specifica on by yourself, please ask the manager for an order form.
Selec on of products can be carried out by our engineers with the help of the specialized program DiaLux.
*Highly efficient LEDs (not less than 109 Lm/W) of Cree and Seoul
Semiconductor produc on are used.
11
LED light
ETSLD'24, ETSLD'36
IndustrialLighting
The LED light is designed for even ligh ng of small workrooms, illumina on of worksites, small open areas,
railway lines, pla orms, pedestrian crossings, etc.
It can also be used for architectural illumina on of buildings.
Opera ng me
100 000 hours
with light decay not more than 30%
*Highly efficient LEDs (not less than 109 Lm/W) of Cree and Seoul
Semiconductor produc on are used.
Specification
Supply voltage, V
Rated frequency, Hz
Protec on class under GOST 14254-96
Clima c category under GOST 15150-69
Electric shock protec on class
Rated power consump on, W
Colour temperature, К
Weight, kg
Light luminous flux, Lm
LED luminous flux, Lm
from 165 to 265
50-60
IP 67
UHL 1
1
31.4
5700-6500
2.8
2300
3100
Specification
Supply voltage, V
Rated frequency, Hz
Protec on class under GOST 14254-96
Clima c category under GOST 15150-69
Electric shock protec on class
Rated power consump on, W
Colour temperature, К
Weight, kg
Light luminous flux, Lm
LED luminous flux, Lm
from 165 to 265
50-60
IP 67
UHL 1
1
47.1
5700-6500
3.5
3400
4600
To avoid inaccuracies in selec ng product specifica on by yourself, please ask the manager for an order form.
Selec on of products can be carried out by our engineers with the help of the specialized program DiaLux.
8. Specification
Supply voltage, V
Rated frequency, Hz
Protec on class under GOST 14254-96
Clima c category under GOST 15150-69
Electric shock protec on class
Rated power consump on, W
Colour temperature, К
Weight, kg
Light luminous flux, Lm
LED luminous flux, Lm
from 165 to 265
50-60
IP 67
UHL 1
1
94.2
5700-6500
6.2
6800
9200
The LED light is designed for func onal
ligh ng of open and covered areas, squares,
transport tunnels, railway lines, pla orms,
pedestriancrossingsetc.
It can also be used for architectural ligh ng
ofbuildings.
12
IndustrialLighting
LED light
ETSLD 72
Opera ng me
100 000 hours
with light decay not more than 30%
*Highly efficient LEDs (not less than 109 Lm/W) of Cree and Seoul
Semiconductor produc on are used.
Lighting models For ETSLD-72 at the height of 10m
Optics angle of 60 degrees Optics angle of 20x40 degrees
Height, m
Mul plier
*То calculate illumina on level at a height needed, please use a mul plier.
To avoid inaccuracies in selec ng product specifica on by yourself, please ask the manager for an order form.
Selec on of products can be carried out by our engineers with the help of the specialized program DiaLux.
Specification
Supply voltage, V
Rated frequency, Hz
Protec on class under GOST 14254-96
Clima c category under GOST 15150-69
Electric shock protec on class
Rated power consump on, W
Colour temperature, К
Weight, kg
Light luminous flux, Lm
LED luminous flux, Lm
from 165 to 265
50-60
IP 67
UHL 1
1
177
5700-6500
16.6
13500
17100
*Highly efficient LEDs (not less than 109 Lm/W) of Cree and Seoul
Semiconductor produc on are used.
The LED direct-light luminaire is designed for
illumina on of open areas, squares, highways,
traffic interchanges and similar objects. The
light is mounted on a mast system up to 30
meterhigh.
The illuminated area can reach more than
25000sq.matilluminancerateof5lux.
13
Mast LED Lighting System
ETSLD'140 TW
High-mastLighting
Opera ng me
100 000 hours
with light decay not more than 30%
Isolines ETSLD-140-TW illumination model
To avoid inaccuracies in selec ng product specifica on by yourself, please ask the manager for an order form.
Selec on of products can be carried out by our engineers with the help of the specialized program DiaLux.
9. Specification
Supply voltage, V
Rated frequency, Hz
Electric shock protec on class
Protec on class under GOST 14254-96
Clima c category under GOST 15150-69
Rated power consump on, W
Colour temperature, К
Weight, kg
Light luminous flux, Lm
LED luminous flux, Lm
from 165 to 265
50-60
1
IP 67
UHL 1
47.1
5700-6500
16.6
3400
4600
*Highly efficient LEDs (not less than 109 Lm/W) of Cree and Seoul
Semiconductor produc on are used.
14
StreetLighting
LED Street Light
ETSLD'36 ST
TheLEDlightisdesignedforillumina onoflocalstreetsandroads,
district roads, main urban arteries, open areas, sports grounds
and parks. It is used to replace tradi onal street lights with high-
pressure mercury arc lampsDRL-150. Modifica ons with required
luminous flux distribu on depending on a typeof applied
secondary op cs are available. Modifica on of ETSLD-36-ST-02
withLEDluminousfluxof6418,8available.
Opera ng me
100 000 hours
with light decay not more than 30%
Light distribution diagram Illumination Model of ETSLD-36-ST
To avoid inaccuracies in selec ng product specifica on by yourself, please ask the manager for an order form.
Selec on of products can be carried out by our engineers with the help of the specialized program DiaLux.
TheLEDlightisdesignedforillumina onoflocalstreetsandroads,open
areas, sports grounds, parks. It is used to replace tradi onal street lights
withhigh-pressuremercuryarclampsDRL-150andDRL-250.
Modifica ons with required luminous flux distribu on depending
onatypeofappliedsecondaryop csareavailable.
A modifica on of ETSLD-60-ST-02 with the luminous flux of 9919.3
lumenisavailable.
15
LED Light
ETSLD'60-130 ST
StreetLighting
Opera ng me
100 000 hours
with light decay not more than 30%
Specification
Supply voltage, V
Rated frequency, Hz
Protec on class under GOST 14254-96
Clima c category under GOST 15150-69
Electric shock protec on class
Rated power consump on, W
Colour temperature, К
Weight, kg
Light luminous flux, Lm
LED luminous flux, Lm
from 165 to 265
50-60
IP 67
UHL 1
1
60-146
5700-6500
9
5800-14500
7700-18100
*Highly efficient LEDs (not less than 109 Lm/W) of Cree and Seoul
Semiconductor produc on are used.
To avoid inaccuracies in selec ng product specifica on by yourself, please ask the manager for an order form.
Selec on of products can be carried out by our engineers with the help of the specialized program DiaLux.
10. Specification
Conformity
Supply voltage, V
Rated frequency, Hz
Electric shock protec on class
Protec on class under GOST 14254-96
Clima c category under GOST 15150-69
Rated power consump on, W
Luminous flux, Lm
Colour temperature ,K
Weight, kg
GOST 60598
from 175 to 265
50-60
1
IP 20
U
7
900*
5700-6500
2.0
*Highly efficient LEDs (not less than 109 Lm/W) of Cree and Seoul
Semiconductor produc on are used.
16
Lightingofhousing
andutilityfacilities
LED light for housing and utility sector
ETSLD'80 HUS
The LED light is designed for illumina on of auxiliary
rooms: stair wells, passages, elevator halls and other
rooms for people's temporary staying in public
and residen al buildings. The light has built-in light and
mo on sensors. The light is an -vandal. It is used
to replace lights based on 80 W incandescent lamps.
Itismodifiedtoreduceluminousflux.
Opera ng me
50 000 hours
under stand-by condi ons
Light distribution diagram
17
LED park light
ETSLD'48 PR
Lightingofhousing
andutilityfacilities
LED park light is designed for illumina on of open
spaces, parks, squares, building surrounding
grounds and car parking lots. It may be used
forillumina onofcountrybuildings,etc.
The light is equipped with Acriche produc on LEDs
of220Vwithoutpowersupply.
Opera ng me
50 000 hours
under stand-by condi ons
Specification
Supply voltage, V
Rated frequency, Hz
Electric shock protec on class
Protec on class under GOST 14254-96
Clima c category under GOST 15150-69
Rated power consump on, W
Luminous flux, Lm
Colour temperature ,K
Weight, kg
from 165 to 265
50-60
1
IP 65
UHL 1
60
3100*
5700-6500
5.5
*Highly efficient LEDs (not less than 109 Lm/W) of Cree and Seoul
Semiconductor produc on are used.
Light distribution diagram
11. Specification
Supply voltage, V
Rated frequency, Hz
Electric shock protec on class
Protec on class under GOST 14254-96
Clima c category under GOST 15150-69
Rated power consump on, W
Colour temperature, K
Weight, kg
Light luminous flux, Lm
LEDs luminous flux, Lm
from 165 to 265
50-60
1
IP 20
U-3.1
from 30 to 50
5700-6500
3.0
2100-4800
2800-5600
*Highly efficient LEDs (not less than 109 Lm/W) of Cree and Seoul
Semiconductor produc on are used.
18
ETSLD’24-48ARM
The LED light is designed for installa on into
Armstrong ceilings or suspended ceilings in offices,
public places, conference halls, mee ng rooms,
kindergartens, hospitals, shops, classrooms and
otherrooms.Anykindofglasscanbeinstalled.
Modifica on of Armstrong type grille lamps
isavailable.
Opera ng me
50 000 hours
under stand-by condi ons
OfficeLighting
LED office light
ETSLD'24-48 ARM
19
LED Light
ETSLD'60-130 ST
StreetLighting
Thephotometriclaboratory“SVETOLAB”carriesoutmeasure-
mentsoflight-emi ngdevicescharacteris cs.
The photometric laboratory has an accredita on
cer ficate that proves its conformity to GOST ISO/IES 17025-
2009 “General Requirements for the Competence of Tes ng
and Calibra on Laboratories” and proves it independence and
competency. The laboratory guarantees the privacy
ofmeasurementresults.
The laboratory carries out the assessment of claimed
specifica ons conformity to the real ones. LLC “SVETOLAB”
is a connec ng link between the produc on and introduc on
of light equipment. The photometric laboratory allows
to improve the quality of light equipment and helps
toimplementnewligh ngenergysavingtechnologies.
The laboratory includes the following measuring instru-
mentsandequipment:
A goniophotometer, a spectrophotocolorimeter, 2 m
integra ng sphere, 0,3 m integra ng sphere, a digital power
supply,adigitalpowermeter,aPWMpowersupply.
Main measurements made at the laboratory:
Luminous intensity spa al distribu on diagram with a pitch
up to 0,5 degree in all planes;
3D diagram of luminous intensity distribu on in space;
Luminous flux, Im;
Distribu on of total luminous flux in luminous intensity
levels or emission angles within a direc onal pa ern;
Illumina on (Irradiance) of surface from the tested emi ng
source at any distance from the la er;
Power consump on of an emi ng source with a power
supply;
Power consump on of an emi ng source with no power
supply;
Consump on current;
Opera ng voltage range tes ng (with no photometric
measurements);
Tes ng luminous flux within an opera ng voltage range
(1 hour);
Power consump on within an opera ng voltage range with
a pitch of 5% of the rated voltage;
Spectral emission distribu on;
Chroma city coordinates X,Y,Z; colour temperature, К;
Es ma on of build-up me for a light source (not more than
1 hour);
Measurement of luminous flux stability at rated voltage,
lumen-W characteris c.