1. www.hoymiles.com
Mark Huang
Sales Specialist - EMEA & APAC
E-mail: mark.huang@hoymiles.com
Tel/Wechat/whatsapp: +86-15613197621
Introduction
of Hoymiles
World leading brand of PV inverter
4. About Hangkai group
• Established since the year of 1958
• Factory area over 200,000 square meter
• Over 2,000 employees & 10 subsidiaries
• Hatched three listed companies in total
Parent company ---- Hangkai Group
5. R&D team of Hoymiles
Zhejiang University Hangkai Group Hoymiles R&D team
+ =
Top 3 in China
Top 60 in world
3 post doctors
10 doctors
25 masters
6. Milestones of Hoymiles
2014
Future
Entered the market of USA, Europe
and Australia with 250W and 500W
micro-inverters. Over 10,000 projects
all around world on rooftop installed
with Hoymiles micro-inverters
2015
Hoymiles ranked the NO.1 in
micro-inverter installation in
China and became the CSA
authorized testing laboratory
2017
Participant to draw up the compulsory
standard of photovoltaic industry for
the on-grid inverter in region of China2013
Has obtained the
certification of
CSA, BV, SAA and
CQC for smart
micro-inverter
2016
Won the second prize
of National Natural
Science. Established
three filial companies
2018
The new 4 in 1 micro-inverter
MI-1200 has achieved the
No.1 CEC weighted efficiency
7. Facts in data
The biggest supplier of micro-
inverter in the market of China
The Biggest2
1
NO.1 weighted efficiency of
CEC for 4 in 1 inverter 96.5%
The Top one
3
The best density of power ever
among all other micro-inverters
The Best one
10+ SCI/EI Papers
80+ SCI/EI Papers
2000+Group staff
100+
R&D Engineers
14. Advantages of micro-inverter
NO.1 CEC weighted efficiency (96.5%) in the
world, modular MPPT ensure 10~30% more
yield of PV energy comparing string inverters
High efficiency
Well chosen components ensure its high quality:
MTBF (mean time between failure) > 550 years;
yearly failure rate < 0.18%; warranty of 12 years
High reliability
Real-time monitoring world widely to control
status of power generation for each module.
Online trouble shooting, quicker and precise
High accuracy
Only 40V at DC side in system of micro-inverter
would totally solve the PID effect, which will
highly improve energy yield and maintenance
Solution of PID
Up to 40V at DC side in system of micro-
inverter would avoid any possible risk of
conflagrations caused by strong drawing arc
and electric shock
High security
Available for various installations of PV system
for modules in different orientation, shadings,
also power extension or reformation of system
High flexibility
15. High security
Micro-inverter
DC voltage < 40V DC voltage > 600V
String inverter
In PV system consisted of micro-inverters, the voltage at DC side is less than 40V, will not cause any
risk of conflagrations, while in conventional system of string inverter, the voltage at DC side are always
between 600~1500V, which will highly lead to fire risk due to strong drawing arc and electric shocks
16. No risk of fire
Under 40V DC Under 600V DC
Slight drawing arc, no electric shock Strong drawing arc and electric shock
Conflagrations of PV systems due to heavy drawing arcs caused by high DC voltage
17. Higher generation
Micro-inverter String inverter
100% 100% 100%50% 50% 50% 50%50%
In PV system consisted of micro-inverters, highest power output from each panel can be achieved by modular
lever MPPT from each micro-inverter, while in conventional system of string inverter, due to the cast effect, its
yield of energy is always limited by the panel which gives the weakest performance under various conditions
18. Higher efficiency
Brand Country Model Efficiency
Hoymiles China MI-250 96.5%
Enphase USA M250 96.5%
ABB Sweden MICRO-0.3I 96.0%
Enecsys UK 280-60-XX 96.0%
SMA Germany SB 240-US-10 96.0%
APS China YC500A(240V) 95.0%
Involar China MAC500-XX 94.5%
i-Energy China GT260 92%
The official list of CEC efficiency tested by the 3rd partyCEC Weighted Efficiency for 4-in-1 (MI-1200)---96.5%
NO.1 CEC efficiency for micro-inverter in the world since 2015
19. High reliability
1,500 thousand tests on DC switching
1 million tests about electrical shocks
Surge and lighting strike test at 6000V
Totally water-proof with grade of IP67
Water-proof and dust-proof design at IP67 grade,
can be normally operated after disposal under
depth of water of 1 meter after one entire week,
thus it can resist all kinds of harsh environments
20. Reliable components
All key components of Hoymiles micro-inverters are totally supplied by top-class brands around the
world, which makes our quality much superior than us, thus we can offer standard warranty for at least
12 years, much longer than the standard warranty from conventional string inverters, for only 5 years
High reliability comes from well-chosen components
22. Model of 4-in-1
Homiles 4-in-1 series inverter is the first micro-inverter of single phase designed for four solar panels with dual MPPT,
also with the best power density ever in photovoltaic industry, thus its weight is extremely light, only 3.75Kg,
including integrated DC and AC cables. The 3 phase wiring makes it easy to be configured in PV system with MW size
Maximum output up to 1200/1500W
The efficiency of CEC weighted 96.50%
Dynamic MPPT efficiency about 99.76%
IP67 enclosure; protection of 6000V surge
24. Parameter of 4-in-1
MI-1200/1500 (for 4* 60 or 4*72 cells)
Power range of module [W] Up to 380/470 (single panel)
Range of MPPT voltage [V] 32~48/36~48
Range of operating voltage [V] 16~60
Start/Maximum input voltage [V] 22/60
Maximum input current [A] 10.5/11.5
Output data (AC) @208V AC @240V AC @220V AC @230V AC
Rated output power [W] 1000/1200/1500 1200/1500 1200/1500 1200/1500
Rated output current [A] 5.77/7.21 5/6.25 5.45/6.81 5.21/6.52
Nominal output voltage/range [V] 208(180~275) 240(180~275) 220(180~275) 230(180~275)
Nominal frequency/range[Hz] 60(58~62) 50(45~55) or 60(55~65)
Power factor >0.99
Total harmonic distortion <3% / <5% <3% / <5% <3% / <5% <3% / <5%
Maximum units per string 3/3 4/3 4/3 4/3
Efficiency 96.6% (CEC peak) / 96.5% (CEC weighted)
Enclosure rating IP67 (Outdoor ~ NEMA6)
Operating temperature [oC] -40 to +65
Dimensions and weight 280*176*33mm / 3.75Kg (including 1.9m AC cable)
Standard warranty [Years] 12 (Extendable to 15, 20, 25 years)
25. Model of 2-in-1
Maximum output up to 500/600/700W
The peak efficiency reaches at 96.70%
Static MPPT efficiency is about 99.80%
IP67 enclosure; protection of 6000V surge
Homiles 2-in-1 series inverter is the first micro-inverter of Daisy-chain designed for two solar panels with dual MPPT,
also with the highest efficiency of CEC weighted 96.5% (NO.1 among all 2-in-1 models in the world since 2015), which
is an ideal solution for applications such as large-scale commercial projects. It is also one of the best-selling product
27. Parameter of 2-in-1
MI-500/600/700 (for 2* 60 or 2*72 cells)
Power range of module [W] Up to 310/380/470 (single panel)
Range of MPPT voltage [V] 27~48/29~48/33~48
Range of operating voltage [V] 16~60
Start/Maximum input voltage [V] 22/60
Maximum input current [A] 10.5/11.5/11.5
Output data (AC) @208V AC @240V AC @220V AC @230V AC
Rated output power [W] 500/600/700 500/600/700 500/600/700 500/600/700
Rated output current [A] 2.40/2.88/3.36 2.08/2.50/2.91 2.27/2.72/3.28 2.17/2.60/3.04
Nominal output voltage/range [V] 208(180~275) 240(180~275) 220(180~275) 230(180~275)
Nominal frequency/range[Hz] 60(58~62) 50(45~55) or 60(55~65)
Power factor >0.99
Total harmonic distortion <3% <3% <3% <3%
Maximum units per string 9/7/6 10/8/7 10/8/7 10/8/7
Efficiency 96.7% (CEC peak) / 96.5% (CEC weighted)
Enclosure rating IP67 (Outdoor ~ NEMA6)
Operating temperature [oC] -40 to +65
Dimensions and weight 250*170*28mm / 3.00Kg (including 1.9m AC cable)
Standard warranty [Years] 12 (Extendable to 15, 20, 25 years)
28. Model of 1-in-1
Maximum output up to 250/300/350W
The efficiency of CEC weighted 96.50%
Dynamic MPPT efficiency about 99.76%
IP67 enclosure; protection of 6000V surge
Homiles single unit series inverter is the designed with Daisy-chain connection, with quite wide range of DC input
operating voltage(16~60V), and low start-up voltage(22V), can be perfectly applied in PV system of either single or
three phases, and also ideally applied with uneven numbers of solar panels or under complex conditions in installations
29. 1Φ connecting scheme
Panel of AC
distribution
W
End cap
per string
Ground
Neutral
AC string cable
Meter
Circuit
breaker
Single
phase
30. Parameter of 1-in-1
MI-250/300/350 (for 1* 60 or 1*72 cells)
Power range of module [W] Up to 310/380/440 (single panel)
Range of MPPT voltage [V] 27~48/29~48/33~48
Range of operating voltage [V] 16~60
Start/Maximum input voltage [V] 22/60
Maximum input current [A] 10.5/11.5/11.5
Output data (AC) @208V AC @240V AC @230V AC
Rated output power [W] 250/300/350 250/300/350 250/300/350
Rated output current [A] 1.20/1.44/1.68 1.04/1.25/1.45 1.08/1.30/1.52
Nominal output voltage/range [V] 208(180~275) 240(180~275) 230(180~275)
Nominal frequency/range[Hz] 60(58~62) 60(58~62) 50(45~55) or 60(58~62)
Power factor >0.99
Total harmonic distortion <3% <3% <3%
Maximum units per string 18/15/13 21/17/15 20/16/14
Efficiency 96.7% (CEC peak) / 96.5% (CEC weighted)
Enclosure rating IP67 (Outdoor ~ NEMA6)
Operating temperature [oC] -40 to +65
Dimensions and weight 178*153*28mm / 1.98Kg (including 1m AC cable)
Standard warranty [Years] 12 (Extendable to 15, 20, 25 years)
31. Monitoring system
Key features of Hoymiles smart monitoring system
Modular level
Operational status from each panel unit can be
monitored to find out fault of system precisely
Hoymiles DTU can store data locally for 168 hours
during malfunctions of router, and reload data later
Data conservation
Firmware of Hoymiles can be rebooted, shutdown,
or updated remotely to make maintenance easier
Remote control
32. Setup of monitoring
How to set up a monitoring system of Hoymiles?
The monitoring application can be easily downloaded and accessed by end users with their smartphone
or pad; each monitoring platform to PV system of Hoymiles can be configured in only three easy steps
3. Design for layout
2. Input basic information
1. Create new station by click the List
36. Parameter of DTU
DTU-G100/-W100 DTU-MI-GRPS DTU-433 Repeater
Communications at side of micro-inverter
Signal of communication 2.4G RF 2.4G RF - 2.4G RF
Time rate per sampling 5 minutes 5 minutes 5~15 minutes 5 seconds
Maximum distance (open space) 200m 200m - 200m
Maximum PV panels connected 99 99 490 99
Power supply
Method of power supply USB adapter External adapter External adapter -
Input voltage and frequency [V/Hz] 100~240/50~60 100~240/50~60 100~240/50~60 100~240/50~60
Output voltage and current 5V/2A 5V/0.8A 5V/0.8A -
Power consumption [W] 1(standard)~5(Max.) 2.5~5(Max.) 2.5~5(Max.) 0.5~1(Max.)
General parameters
Operating temperature [oC] -20 ~ +55 -20 ~ +55 -20 ~ +65 -40 ~ +65
Dimensions [W*H*D mm] 143*33*12.5 149*90*31 149*90*31 145*125*60
Weight [Kg] 0.1 0.22 0.22 0.35
Display and mounting LED / plug-in LCD / on wall LCD / on wall -
Other aspects
Communications in clouds GSM/ Wifi RJ45 / GPRS RJ45 Ethernet 470M-LORA
Standard warranty [Years] 1 1 1 1
37. Accessories
Name Description of function Name Description of function
1. DC extension cable Inverter to PV, MC4 male and female connectors 6. AC male end cap To cover AC male connector of micro-inverter, IP67
2. AC extension cable Between inverters, MC4 male and female connectors 7. AC female end cable To connect the last inverter with AC distributor
3. AC female end cap To cover AC female connector of micro-inverter, IP67 8. Screws To fix each micro-inverters with two M8*25 screws
4. AC unlock tool To unplug the AC connector 9. DC unlock tool To unplug the DC connector
5. AC male connector Connect inverter to AC end cap or extensional cable 10. AC female connector Connect inverter to AC end cap or extensional cable
10
1 2 3 4 5
9876
38. HYBRID INVERTER
S O L A R S O L U T I O N S
Introduction of
Hybrid inverter
Part 3
39. Hybrid system
Structural diagram of hybrid system for residential
TransformerTransformer
400V 10KV 400V
Grid Grid
AC
Loads
Monitoring
Charging pile
AC
Battery pack
DC
DC
PV array Smart meter
Communication
AC
Hybrid inverter
hoymiles
AC
Key loads
40. Homiles hybrid inverter
Homiles hybrid inverter
Homiles HY serires is hybrid inverter of single-
phase, which is compatible with both storage
solutions consisting of both lithium-ion cells as
well as lead-carbon batteries. All PV and storage
activities are monitored by remote cloud platform
Increase self-consumption to 80%+
Protection against power outage
Controls of feed-in and charging
Online monitoring for all system
41. Scenarios of application
Single phase hybrid inverter
PV modules
1Φ inverter
Energy management
Battery system
Three phases hybrid inverter
Energy management
Battery system
3Φ inverter
PV modules
42. 1Φ hybrid inverter
HY1-3000HV HY1-3700HV HY1-4600HV HY1-5000HV
Max input DC power [W] 4000 5000 6000 6000
Nominal/Max DC voltage [V] 360/600 360/600 360/600 360/600
Max input/short circuit current [A] 10/14 10/14 10/14 10/14
MPPT voltage range [V] 125~550 125~550 125~550 125~550
MPPT number/string per tracker 2/1 2/1 2/1 2/1
Nominal/Max output AC power [W] 3000 3680 4600 5000
Rated grid voltage/range [V] 230(180~270) 230(180~270) 230(180~270) 230(180~270)
Rated frequency of grid[Hz] 50/60 50/60 50/60 50/60
Nominal/Max AC current [A] 13/14.4 16/16 20/21 21.7/21.7
Battery voltage/range [V] 300/85~400 300/85~400 300/85~400 300/85~400
Max charging/discharging data 6000W, 20A
EPS rated/peak power [VA/W] 4000/8000 4000/8000 5000/8000 5000/8000
EPS rated current and voltage 17.4A/230V 17.4A/230V 21.7A/230V 21.7A/230V
Efficiency of charge and discharge 96.5% (PV-Battery)/ 97%(Battery-AC)
Protection class and cooling IP65/ Natural convection
Operating temperature [oC] -20 to +60 (Derating at +45)
Dimensions and weight 482*464*182mm / 26.9Kg
Standard warranty [Years] 5 (Extendable to 10, 15, 20, 25)
43. 3Φ hybrid inverter
HY3-5000HV HY3-6000HV HY3-8000HV HY3-10000HV
Max input DC power [W] 6000 8000 10000 13000
Nominal/Max DC voltage [V] 720/1000 720/1000 720/1000 720/1000
Max input/short circuit current [A] 11/14 11/14 11/14 20/23
MPPT voltage range [V] 230~800 280~800 370~800 330~800
MPPT number/string per tracker 2/1 2/1 2/1 2/1
Nominal/Max output AC power [W] 5000 6000 8000 10000
Rated grid voltage/range [V] 400(360~440) 400(360~440) 400(360~440) 400(360~440)
Rated frequency of grid[Hz] 50/60 50/60 50/60 50/60
Nominal/Max AC current [A] 7.6/8.5 9/10 12.2/13.5 15/16
Battery voltage/range [V] 200/170~500 240/170~500 320/170~500 400/170~500
Max charging/discharging data 6000W, 25A 8000W, 25A 10000W, 25A 10000W, 25A
EPS rated/peak power [VA/W] 5000/7500 6000/9000 8000/12000 10000/14000
EPS rated current and voltage 7.2A/400V 8.7A/400V 11.6A/400V 14.5A/400V
Efficiency of charge and discharge 97.8% (PV-Battery)/ 96%(Battery-AC)
Protection class and cooling IP65/ Natural convection
Operating temperature [oC] -20 to +60 (Derating at +45)
Dimensions and weight 456*655*228mm / Kg
Standard warranty [Years] 5 (Extendable to 10, 15, 20, 25)
44. Why storage for PV?
The major reason of storage for PV is because the PV generation usually does not meet requirement from actual
consumption at certain period during a day. Moreover storage can help to solve uncertainty of PV generation
KW
0 12 24
PV generation
PV consumption
Storage consumption
45. Peak shaving & valley filling
PV generation firstly supplies power to loads, then to battery
if PV power is less than load, battery will discharge for load
hoymiles
Inverter Meter GridBattery
Loads
A
C
D
C
DC
Morning
hoymiles
Inverter Meter GridBattery
Loads
ACAC
A
C
D
C
DC
Afternoon
When PV generation is getting strong, the loads and battery
are fully supplied, then residual power will be fed into grid
46. Peak shaving & valley filling
PV generation stops power supply to loads, then the battery
will discharge its power to loads in order to save electric bill
hoymiles
Inverter Meter GridBattery
Loads
A
C
DC
Evening
When energy in battery restored in the daytime is totally
consumed, the grid will charge and supply power to load
hoymiles
Inverter Meter GridBattery
Loads
ACAC
A
C
DC
Midnight
Priority of power supply: PV>grid>battery Priority of power consumption: load>battery>grid
47. Priority of power supply: PV>battery>grid
Illumination decreases
Loads
Battery
Grid
Self-consumption
48. Illumination decreases
Priority of power supply: PV>battery>grid
Prior consumption is from grid if it is stable,
otherwise the priority will be from battery
Loads
Battery
Grid
Unstable grid
51. Services for clients
We provide customized services to all clients in
terms of system design of PV power station,
implementation, optimization, selection of
products, consultation and necessary supports
System design
Follow-up visits are arranged by our after sales
team per annum within period of warranty in
order to check any possible failures in facilities
and to make sure proper function in installation
Regular visits
All clients can reach us by our 24/7 hotline in
case of any failure of products, afterwards our
technicians will contact with them to analyze
problems, and guide them in trouble shooting
Hotline service
According to various requirements from clients
we shall offer them on-site trainings to share
the specialized knowledge with them, including
device diagnosis, debugging and maintenance
Client training
If the problems could not be solved via hotline,
then our engineers will be sent to sites in a
timely manner to clear all faults, in order to
ensure the proper functioning of our devices
On-site service
Customized services and their corresponding
agreements are available to meet the specific
needs from all clients, including: secondary
development, special test, warranty extension…
Customized service