Your SlideShare is downloading. ×

FEAM Lighting - Hazardous Area & Explosion Proof Lighting

2,218

Published on

T&D are distributors for the FEAM range of Hazardous Area Lighting for installation in potentially explosive atmospheres - FEAM lighting is specified for hazardous areas Zone 1 and Zone 2 (Gases) with …

T&D are distributors for the FEAM range of Hazardous Area Lighting for installation in potentially explosive atmospheres - FEAM lighting is specified for hazardous areas Zone 1 and Zone 2 (Gases) with international certifications according to ATEX, Inmetro, GOST-R, GOST-K, IECEx and CE.

Published in: Technology, Business, Design
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
2,218
On Slideshare
0
From Embeds
0
Number of Embeds
2
Actions
Shares
0
Downloads
15
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. LIGHTING FIXTURES FOR FLUORESCENT TUBE LAMPS Explosion Proof Electrical Equipment EVF Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURES ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIC T5/T4 DIP A21 TA (100…135)°C 1Ex d IIC T5/T4 DIP A21 TA (100…135)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 ISSEP 02 ATEX 043 POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T5/T4 II 2 D Ex tD A21 T100°C / T135°C EXECUTION installation PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE EMERGENCY UNIT ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIC T6 DIP A21 TA T85°C 1Ex d IIC T6 DIP A21 TA T85°C ZONA 1 / 2 - ZONA 21 / 22 ZONA 1 / 2 - ZONA 21 / 22 ZONA 1 / 2 - ZONA 21 / 22 IP66 IP66 IP66 INERIS 08 ATEX 018 POCC IT. ГБ05.B02537 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-0; EN 61241-1; ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T6 II 2 D Ex d tD A21 T85°C EXECUTION installation PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body marine grade copper free aluminium (control gear & emergency unit) Tubes high-temperature resistant borosylicate glass tube painting external epoxy powders grey ral-9006 colour screws external stainless steel gaskets nbr rubber reflectors white stove enamelled sheet steel cable entry 3/4” npt size threaded Electrical characteristics power supply elettronic ballast 220v/240v - 50/60hz (p.f.corrected - cos ρ ≥ 0,98) lampholders bi-pin g13 cap internal wiring high-temperature resistant silicon rubber insulation cables emergency unit emergency unit composed of inverter charger and ni-cd battery pack 4A/h 6v. autonomy from 60 to 120min. Led power-on indicating lamp provided On Request Accessories: • Pole mounting kit complete with stainless steel hardware • Ceiling mounting kit complete with stainless steel hardware • Pendant mounting kit complete with stainless steel hardware • Wall/Structure mounting kit complete with stainless steel hardware • Galvanized steel wire protection guard • Stainless steel wire protection guard • Stainless steel reflectors • External painting colour on request • Electronic ballast with voltage supply different than standard • Ni-Cd Battery pack 7A/h 6V for Emergency Unit with Autonomy more than 150min Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 1 EVF Ex Lighting
  • 2. Ex Lighting EVF Technical data TEMPERATURE CLASS (GAS) LAMP EVF CODE TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE ENTRY EMERGENCY UNIT AUTONOMY DETAIL FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 220V/240V - 50/60Hz T5 T4 T 100°C T 135°C G13 2 x 3/4” - - A T5 T4 T 100°C T 135°C G13 2 x 3/4” - - A T5 T4 T 100°C T 135°C G13 2 x 3/4” - - A T5 T4 T 100°C T 135°C G13 2 x 3/4” - - B T5 T4 T 100°C T 135°C G13 2 x 3/4” - - B T5 T4 T 100°C T 135°C G13 2 x 3/4” - - B EVF18EL 1 x 18W EVF36EL 1 x 36W EVF58EL 1 x 58W EVF18BEL 2 x 18W EVF36BEL 2 x 36W EVF58BEL 2 x 58W EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 220V/240V - 50/60Hz T5 T4 T 100°C G13 T 135°C 1 x 3/4” 4.8 V 1 x 1/2” 4Ah 2h C T5 T4 T 100°C G13 T 135°C 1 x 3/4” 1 x 1/2” 4.8 V - 4Ah 2h C T5 T4 T 100°C G13 T 135°C 1 x 3/4” 1 x 1/2” 4.8 V - 4Ah 2h C T5 T4 T 100°C G13 T 135°C 1 x 3/4” 1 x 1/2” 4.8 V - 4Ah 2h D T5 T4 T 100°C G13 T 135°C 1 x 3/4” 1 x 1/2” 4.8 V - 4Ah 2h D T5 T4 T 100°C G13 T 135°C 1 x 3/4” 1 x 1/2” 4.8 V - 4Ah 2h D EVF18ELME 1 x 18W EVF36ELME 1 x 36W EVF58ELME 1 x 58W EVF18ELBE 2 x 18W EVF36ELBE 2 x 36W EVF58ELBE 2 x 58W EVF Technical features A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL EVF18EL CODE 1000 96 95 602 4,50 2 x 3/4” A EVF36EL 1600 96 95 1202 5,70 2 x 3/4” A EVF58EL 1900 96 95 1490 7,00 2 x 3/4” A EVF18BEL 1000 200 95 602 9,00 2 x 3/4” B EVF36BEL 1600 200 95 1202 12,20 2 x 3/4” B EVF58BEL 1900 200 95 1490 14,70 2 x 3/4” B Reference details A A D 8MA C 8MA B 3/4” B A D 8MA B C 8MA 3/4” Since 1961 2 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 3. Ex Lighting EVF Technical features A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL 1000 222 379 602 10,00 1 x 3/4” / 1 x 1/2” C EVF36ELME 1600 222 379 1202 12,00 1 x 3/4” / 1 x 1/2” C EVF58ELME 1900 222 379 1490 14,00 1 x 3/4” / 1 x 1/2” EVF CODE EVF18ELME C EVF18ELBE 1000 287 265 602 16,00 1 x 3/4” / 1 x 1/2” D EVF36ELBE 1600 287 265 1202 19,00 1 x 3/4” / 1 x 1/2” D EVF58ELBE 1900 287 265 1490 21,00 1 x 3/4” / 1 x 1/2” D Reference details C A B 1 -1/2” C D 3/4” 3/4” D A B 3/4” D 3/4” C 1 -1/2” EVF Installation and mounting details Wall/structure mounting type 4 108 45 Pole mounting Assemblig detail with pole (typical) 3/4” 50 273 50 50 100 100 45° 8 12 45° 273 10 0 8 12 type 3 45 45 170 156 type 2 156 type 1 Pendant mounting 170 Ceiling mounting Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 3
  • 4. Ex Lighting EVF Polar diagrams – photometric data EVF EVF18BEL EVF36BEL EVF58BEL EVF On request accessories CODE GABBIAEVFF18 DESCRIPTION INSTALLATION 18W SIZE GALVANIZED STEEL WIRE PROTECTION GUARD MATERIAL GALVANIZED STEEL GABBIAEVFF36 36W SIZE GALVANIZED STEEL WIRE PROTECTION GUARD GALVANIZED STEEL GABBIAEVFF58 58W SIZE GALVANIZED STEEL WIRE PROTECTION GUARD GALVANIZED STEEL GABBIAEVFF18IX 18W SIZE STAINLESS STEEL WIRE PROTECTION GUARD STAINLESS STEEL GABBIAEVFF36IX 36W SIZE STAINLESS STEEL WIRE PROTECTION GUARD STAINLESS STEEL GABBIAEVFF58IX 58W SIZE STAINLESS STEEL WIRE PROTECTION GUARD STAINLESS STEEL D18IX 18W SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL D36IX 36W SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL D58IX 58W SIZE STAINLESS STEEL REFLECTOR 20301.0151 SINGLE LAMP CEILING MOUNTING KIT C/W HARDWARE STAINLESS STEEL TYPE 1 ALUM. LIGHT ALLOY 20301.0152 TWIN LAMP CEILING MOUNTING KIT C/W HARDWARE TYPE 1 ALUM. LIGHT ALLOY 20301.0153 SINGLE LAMP POLE MOUNTING KIT (SIZE 1” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0155 SINGLE LAMP POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0156 TWIN LAMP POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0157 SINGLE LAMP POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0158 TWIN LAMP POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20302.0128 SINGLE LAMP WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL 20302.0128 TWIN LAMP WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL 20301.0165 SINGLE LAMP PENDANT MOUNTING KIT C/W HARDWARE TYPE 2 GALVANIZED STEEL 20301.0165 TWIN LAMP PENDANT MOUNTING KIT C/W HARDWARE TYPE 2 GALVANIZED STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 4 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 5. LIGHTING FIXTURES FOR INCANDESCENT AND DISCHARGE LAMPS Explosion Proof Electrical Equipment EVAC Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURE / CONTROL GEAR ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0054X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T6/T2 II 2 D Ex tD A21 T80°C / T290°C EXECUTION installation PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body marine grade copper free aluminium (control gear & lamp body) Globe high-temperature resistant borosylicate glass painting external epoxy powders grey ral-9006 colour screws external stainless steel gaskets silicon rubber cable entry 3/4” npt size threaded Installation swivel bracket AISI 316L stainless steel Electrical characteristics Power supply (prc) conventional ballast 230V - 50Hz (p.f. corrected - cos ρ ≥ 0,95) Lampholders porcelain E27/E40 size Internal wiring high-temperature resistant silicon rubber insulation cables Terminals suitable up to 4mm/sq cables On Request Accessories: •Ceiling mounting AISI 316L stainless steel kit complete with stainless steel hardware •Pendant mounting AISI 316L stainless steel kit complete with stainless steel hardware •Pole mounting kit 1” – 1 1/2” – 2” dia. complete with stainless steel hardware •Wall/Structure mounting kit complete with stainless steel hardware •Galvanized steel wire protection guard •Stainless steel wire protection guard •White stove enamelled aluminium reflectors •Stainless steel reflectors •External painting colour on request •Control gear with voltage supply different than standard •Threaded cable entry different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 5 EVAC Ex Lighting
  • 6. Ex Lighting EVAC EVAC Technical data CODE TEMPERATURE CLASS (GAS) LAMP TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY SIZE DETAIL LIGHTING FIXTURE FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz EVAC101 100 W EVAC100 100 W EVAC201 T4 T 130°C E-27 1 x 3/4" A T4 T 130°C E-27 2 x 3/4" B 200 W T4 T3 T 130°C T 195°C E-27 1 x 3/4" A EVAC200 200 W T4 T3 T 130°C T 195°C E-27 2 x 3/4" B EVAC301 300 W T4 T3 T 130°C T 195°C E-40 1 x 3/4" A EVAC300 300 W T4 T3 T 130°C T 195°C E-40 2 x 3/4" B EVAC501 500 W T3 T 195°C E-40 1 x 3/4" A EVAC500 500 W T3 T 195°C E-40 2 x 3/4" B EVAC100-E20 25 W 20 W T5 T4 T 95°C T 130°C E-14 + Ba-15s 2 x 3/4" B 1 x 3/4" A LIGHTING FIXTURE FOR HALOGEN LAMP - POWER SUPPLY 230V-50Hz EVAC101-100H 100 W T4 T 130°C E-27 EVAC100-100H 100 W EVAC201-150H 150 W T4 T 130°C E-27 2 x 3/4" B T1 T 130°C E-27 1 x 3/4" A EVAC200-150H 150 W T2 T 130°C E-27 2 x 3/4" B 250 W T4 T3 T 130°C T 195°C EVAC301-250H E-27 1 x 3/4" A EVAC300-250H 250 W T4 T3 T 130°C T 195°C E-27 2 x 3/4" B LIGHTING FIXTURE FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V-50Hz EVAC101-80HG 80 W T4 T 130°C E-27 2 x 3/4” / 1 x 1-1/2” C EVAC201-125HG 125 W T3 T 195°C E-27 2 x 3/4” / 1 x 1-1/2” C EVAC301-250HG 250 W T3 T 195°C E-40 2 x 3/4” / 1 x 1-1/2” C EVAC501-250HG 250 W T4 T 130°C E-40 2 x 3/4” / 1 x 1-1/2” C EVAC501-400HG 400 W T3 T 195°C E-40 2 x 3/4” / 1 x 1-1/2” C LIGHTING FIXTURE FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V-50Hz EVAC101-70HPNA 70 W T4 T 130°C E-27 2 x 3/4" / 1 x 1-1/2" C EVAC301-150HPNA 150 W T4 T 130°C E-40 2 x 3/4" / 1 x 1-1/2" C EVAC301-250HPNA 250 W T3 T2 T 195°C T 290°C E-40 2 x 3/4" / 1 x 1-1/2" C EVAC501-400HPNA 400 W T3 T 195°C E-40 2 x 3/4" / 1 x 1-1/2" C LIGHTING FIXTURE FOR METAL HALIDE LAMP - POWER SUPPLY 230V-50Hz EVAC101-100MH 100 W T4 T 130°C E-27 2 x 3/4" / 1 x 1-1/2" C EVAC301-150MH 150 W T4 T3 T 130°C T 195°C E-27 2 x 3/4" / 1 x 1-1/2" C EVAC301-250MH 250 W T3 T 195°C E-40 2 x 3/4" / 1 x 1-1/2" C EVAC501-400MH 400 W T3 T 195°C E-40 2 x 3/4" / 1 x 1-1/2" C LIGHTING FIXTURE FOR BLENDED LIGHT LAMP - POWER SUPPLY 230V-50Hz EVAC201-160MLL 160 W T3 T 195°C E-27 2 x 3/4" / 1 x 1-1/2" A EVAC200-160MLL 160 W T3 T 195°C E-27 2 x 3/4" / 1 x 1-1/2" B EVAC301-250MLL 250 W T3 T 195°C E-40 2 x 3/4" / 1 x 1-1/2" A EVAC300-250MLL 250 W T3 T 195°C E-40 2 x 3/4" / 1 x 1-1/2" B Since 1961 6 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 7. Ex Lighting EVAC Technical features CODE B [mm] C [mm] Ø D [mm] Ø E [mm] weight [Kg] CABLE ENTRY DETAIL 150 270 240 145 280 3,50 1 x 3/4” A EVAC100 150 270 240 145 280 3,50 2 x 3/4” B EVAC201 175 290 270 170 345 4,00 1 x 3/4” A EVAC200 175 290 270 170 345 4,00 2 x 3/4” B EVAC301 200 390 330 190 402 7,00 1 x 3/4” A EVAC300 200 390 330 190 402 7,00 2 x 3/4” B EVAC501 260 420 395 255 515 10,00 1 x 3/4” A EVAC500 260 420 395 255 515 10,00 2 x 3/4” B Reference details Reference details A B A 3/4” A 2X3/4” B Ø8 .5 60 60 16 80 C 80 60 C B 3 200 180 D E D E CODE A [mm] B [mm] C [mm] Ø D [mm] Ø E [mm] weight [Kg] CABLE ENTRY DETAIL 545 515 145 280 9,00 2 x 3/4” 1 x 1-1/2” C 2 x 3/4” 1 x 1-1/2” C 2 x 3/4” 1 x 1-1/2” C 2 x 3/4” 1 x 1-1/2” C EVAC101-..HG EVAC101-..HPNA 225 EVAC101-..MH EVAC201-..HG 225 565 545 170 345 9,50 EVAC301-..HG EVAC301-..HPNA 225 665 640 190 402 12,00 EVAC301-..MH EVAC501-..HG EVAC501-..HPNA 225 695 670 255 515 15,50 EVAC501-..MH Reference details C A 1-1/2” C B 200 5 30 28 28 0 Ø1 192 D E Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 7 EVAC A [mm] EVAC101
  • 8. Ex Lighting EVAC Installation and mounting details 237 16 type 1 Pendant mounting type 2 275 180 54 EVAC Ceiling mounting Wall/structure mounting type 3 283 58 Since 1961 8 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 9. Ex Lighting EVAC Installation and mounting details EVAC Pole mounting / Assemblig detail with pole (typical) SEALING FITTINGS SEALING FITTINGS POLE POLE 25° 25° EVAC Polar diagrams – photometric data EVAC125HG EVAC150HPS EVAC100MH Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 9
  • 10. Ex Lighting EVAC Polar diagrams – photometric data EVAC400HPS-D EVAC400MH-D EVAC EVAC250HG-D EVAC On request accessories CODE 20302.0070 DESCRIPTION INSTALLATION EVAC 100 / 101 SIZE STANDARD REFLECTOR MATERIAL WHITE STOVE ENAMELLED ALUMININIUM 20302.0071 EVAC 200 / 201 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUMININIUM 20302.0072 EVAC 300 / 301 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUMININIUM 20302.0073 EVAC 500 / 501 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUMININIUM 20302.0025 EVAC 100 / 101 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0026 EVAC 200 / 201 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0027 EVAC 300 / 301 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0028 EVAC 500 / 501 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0074 EVAC 100 / 101 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0075 EVAC 200 / 201 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0076 EVAC 300 / 301 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0077 EVAC 500 / 501 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0037 EVAC 100 / 101 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0038 EVAC 200 / 201 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0039 EVAC 300 / 301 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0040 EVAC 500 / 501 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0078 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 AISI 316L STAINLESS STEEL 20302.0079 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 AISI 316L STAINLESS STEEL 20302.0082 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 AISI 316L STAINLESS STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 10 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 11. LIGHTING FIXTURES FOR FLUORESCENT LAMPS Explosion Proof Electrical Equipment EVAC-FL Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURE / CONTROL GEAR ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIC T6 X DIP A21 TA (80)°C 1Ex d IIC T6 X DIP A21 TA (80)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0054X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T6/T2 II 2 D Ex tD A21 T80°C / T290°C EXECUTION installation PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body marine grade copper free aluminium (control gear & lamp body) globe high-temperature resistant borosylicate glass painting external epoxy powders grey ral-9006 colour screws external stainless steel gaskets silicon rubber cable entry 3/4” npt size threaded Installation swivel bracket AISI 316L stainless steel Electrical characteristics Power supply (prc) elettronic ballast 220V/240V - 50/60Hz (p.f.corrected - cos ρ ≥ 0,98) lampholders porcelain e27 size - plastic 2g10 size internal wiring high-temperature resistant silicon rubber insulation cables terminals suitable up to 4mm/sq cables On Request Accessories: •Ceiling mounting AISI 316L stainless steel kit complete with stainless steel hardware •Pendant mounting AISI 316L stainless steel kit complete with stainless steel hardware •Pole mounting kit 1” – 1 1/2” – 2” dia. complete with stainless steel hardware •Wall/Structure mounting kit complete with stainless steel hardware •Galvanized steel wire protection guard •Threaded cable entry different than standard •Stainless steel wire protection guard •White stove enamelled aluminium reflectors •Stainless steel reflectors •External painting colour on request •Electronic ballast with voltage supply different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 11 EVAC-FL Ex Lighting
  • 12. Ex Lighting EVAC-FL EVAC-FL Technical data CODE TEMPERATURE CLASS (GAS) LAMP TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY SIZE DETAIL LIGHTING FIXTURES FOR FLUORESCENT LAMPS - POWER SUPPLY 220V/240V - 50/60Hz EVAC101-15FL 1 x 15W T6 T 80°C E-27 1 x 3/4” A EVAC100-15FL 1 x 15W T6 T 80°C E-27 2 x 3/4” B EVAC201-23FL 1 x 23W T6 T 80°C E-27 1 x 3/4” A EVAC301-218FL 2 x 18W T6 T 80°C 2G-10 2 x 3/4” C EVAC301-318FL 3 x 18W T6 T 80°C 2G-10 2 x 3/4” C EVAC501-236FL 2 x 36W T6 T 80°C 2G-10 2 x 3/4” C EVAC501-336FL 3 x 36W T6 T 80°C 2G-10 2 x 3/4” C EVAC-FL Technical features CODE A [mm] B [mm] C [mm] Ø D [mm] Ø E [mm] EVAC101-15FL 150 270 235 145 280 weight [Kg] CABLE ENTRY 3,5 DETAIL 1 x 3/4” A 150 270 235 145 280 3,5 4 x 3/4” B 175 270 255 170 345 4 1 x 3/4” A EVAC301-218FL 225 180 605 590 190 395 12 2 x 3/4” EVAC301-318FL 225 605 590 190 395 12 2 x 3/4” C EVAC501-236FL 225 648 620 255 515 15,5 2 x 3/4” C EVAC501-336FL 225 620 255 515 15,5 2 x 3/4” 80 A .5 C ∅8 60 80 Reference details B A 3/4” 180 C 3 60 60 200 80 60 16 .5 60 ∅8 648 60 16 Reference details 200 3 80 EVAC100-15FL EVAC201-23FL A 2X3/4” B Ø8 .5 60 0 28 D E 60 16 80 192 28 Ø1 C 80 60 C B 3 200 180 Reference details D E 30 C A 1-1/2” 200 5 C B 200 5 30 28 28 0 Ø1 192 D E Since 1961 12 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 13. Ex Lighting EVAC-FL Installation and mounting details EVAC-FL Ceiling mounting 237 16 type 1 Pendant mounting 275 type 2 54 180 Wall/structure mounting type 3 283 58 Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 13
  • 14. Ex Lighting EVAC-FL EVAC-FL Installation and mounting details Pole mounting SEALING FITTINGS SEALING FITTINGS POLE POLE 25° 25° EVAC-FL On request accessories CODE DESCRIPTION INSTALLATION MATERIAL 20302.0070 EVAC 100 / 101 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM. 20302.0071 EVAC 200 / 201 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM. 20302.0072 EVAC 300 / 301 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM. 20302.0073 EVAC 500 / 501 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM. 20302.0025 EVAC 100 / 101 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0026 EVAC 200 / 201 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0027 EVAC 300 / 301 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0028 EVAC 500 / 501 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL 20302.0074 EVAC 100 / 101 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0075 EVAC 200 / 201 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0076 EVAC 300 / 301 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0077 EVAC 500 / 501 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0037 EVAC 100 / 101 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0038 EVAC 200 / 201 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0039 EVAC 300 / 301 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0040 EVAC 500 / 501 SIZE STAINLESS STEEL PROTECTION GUARD 20302.0078 CEILING MOUNTING KIT C/W HARDWARE 20302.0079 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE 20302.0082 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 1 TYPE 3 TYPE 2 STAINLESS STEEL AISI 316L STAINLESS STEEL AISI 316L STAINLESS STEEL AISI 316L STAINLESS STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 14 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 15. PORTABLE LIGHTING FIXTURES FOR INCANDESCENT LAMPS Explosion Proof Electrical Equipment EVP-100 Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURE ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIC T4 (T5…T2) X DIP A21 TA (130)°C 1Ex d IIC T4 (T5…T2) X DIP A21 TA (130)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0054X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T4/T2 II 2 D Ex tD A21 T130°C EXECUTION installation PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body marine grade copper free aluminium (control gear & lamp body) Globe high-temperature resistant borosylicate glass Painting external epoxy powders grey ral-9006 colour Screws external stainless steel Gaskets silicon rubber Cable entry Nickel plated brass cable gland 1/2” npt (armoured cable) Electrical characteristics Power supply 12 ÷ 230V AC/DC lampholders e27 porcelain On Request Accessories: • External painting colour on request Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 15 EVP-100 Ex Lighting
  • 16. Ex Lighting EVP-100 EVP-100 Technical data CODE LAMP TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY SIZE DETAIL LIGHTING FIXTURE FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz EVP-100 100 W T4 T 130°C E-27 CABLE GLAND 1/2” NPT A EVP-100 Technical features CODE A [mm] B [mm] C [mm] Ø D [mm] weight [Kg] CABLE ENTRY DETAIL 395 257 287 150 4,00 CABLE GLAND 1/2” NPT A EVP-100 Reference details B A A ØD C REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 16 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 17. AIRCRAFT WARNING LIGHTS AND A.W.L. CONTROL PANELS Explosion Proof Electrical Equipment AWL Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D OBSTRUCTION LIGHTING FIXTURE ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0054X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIB+H2 T6…T3 DIP A21 TA 85°C ÷ 150°C 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C 1Ex d IIB+H2 T6…T3 DIP A21 TA 85°C ÷ 150°C 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 II 2 G Ex d IIC T6/T2 II 2 D Ex tD A21 T80°C / T290°C EXECUTION installation PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE CONTROL PANEL II 2 G Ex d IIB+H2 T6...T3 II 2 D Ex tD A21 T85°C ÷ T150°C II 2 G Ex d IIC T6/T2 II 2 D Ex tD A21 T80°C / T290°C EXECUTION PROTECTION DEGREE PROTEZIONE MECCANICA ICAO in according to icao directive ANNEX 14 EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1 RULES OF COMPLIANCE ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 Mechanical characteristics Body marine grade copper free aluminium globe high-temperature resistant borosylicate glass fresnel len shock proof acrilyc material suitable for high temperatures painting external epoxy powders grey ral-9006 colour screws external stainless steel gaskets silicon rubber cable entry 3/4” npt size threaded Electrical characteristics Lampholders porcelain e27 size internal wiring high-temperature resistant silicon rubber insulation cables terminals suitable up to 4mm/sq cables medium intensity flashing obstruction light 1450 / 2000 cd intensity (over than 45mt distance) low intensity steady obstruction light 30 cd intensity (less than 45mt distance) construction single awl - twin awl (1 main + 1 spare) in according to icao directive On Request Accessories: • Galvanized steel wire protection guard • External painting colour on request • Stainless steel wire protection guard • Threaded cable entry different than standard • Aircraft Warning Lights and control panel support manufactured in according to customer specification Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 17 AWL Ex Lighting
  • 18. Ex Lighting AWL Technical data AWL CODE LAMP TYPE TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) FLASHING [x/min.] LAMPHOLDER CABLE ENTRY SIZE DETAIL EVAC201-F 100W INCANDESCENT T4 T 130°C - E-27 1 x 3/4” A EVAC200-F 100W INCANDESCENT T4 T 130°C - E-27 4 x 3/4” A EVAC201-XF 6J XENOFLASH T6 T 80°C 65 ± 10 E-27 1 x 3/4” C EVAC200-XF 6J XENOFLASH T6 T 80°C 65 ± 10 E-27 4 x 3/4” C EVAC201-XFR-24V 6J XENOFLASH T6 T 80°C 65 ± 10 E-27 1 x 3/4” C EVAC201-F2R 2 x 100W INCAND. T4 T 130°C - E-27 1 x 3/4” B EVAC201-XF2R 2 x 6J XENOFLASH T6 T 80°C 65 ± 10 E-27 1 x 3/4” D EVAC301-25R 40W INCANDESCENT T4 T 130°C - E-27 1 x 3/4” C EVAC300-25R 40W INCANDESCENT T4 T 130°C - E-27 4 x 3/4” C AWL Technical features CODE EVAC201-F A [mm] B [mm] Ø C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL 415 200 - 4,50 1 x 3/4” A 430 EVAC200-F 430 415 200 - 4,50 4 x 3/4” A EVAC201-XF 280 260 176 - 4,50 1 x 3/4” C EVAC200-XF 280 260 176 - 4,00 4 x 3/4” C EVAC201-XFR-24V 280 260 176 - 4,00 1 x 3/4” C EVAC201-F2R 790 415 200 475 9,00 1 x 3/4” B EVAC201-XF2R 630 260 176 453 8,00 1 x 3/4” D EVAC301-25R 345 322 197 - 7,00 1 x 3/4” C EVAC300-25R 345 322 197 - 7,00 4 x 3/4” C Reference details A B D ØC ØC A A B B ØC 180 200 Since 1961 18 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 19. Ex Lighting AWL Technical features Reference details D AWL C D ØC ØC A A B B ØC 180 200 Aircraft warning lights models FRESNEL ROTALLARM XENOFLASH MULTI-LED Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 19
  • 20. Ex Lighting AWL AWL Control panels ex d INSTRUMENT HOUSING WITH PHOTOELECTRIC CELL >> 01 BREATHER VALVE TYPE ecd 02 03 AUT. ON MAN. OFF 04 05 ON OFF 12 07 06 ON OFF ON 13 08 15 10 ON OFF OFF 14 09 ON ON OFF OFF 16 11 ON ON OFF 17 OFF 18 19 Weatherproof Ip66 INSTRUMENT HOUSING WITH PHOTOELECTRIC CELL >> BREATHER VALVE TYPE ecde 02 01 03 AUT. ON MAN. OFF 04 05 06 07 EVAC On request accessories CODE DESCRIPTION MATERIAL 20302.0075 EVAC 200 / 201 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0076 EVAC 300 / 301 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0038 EVAC 200 / 201 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0039 EVAC 300 / 301 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0078 STRUCTURE MOUNTING KIT C/W HARDWARE 1030.00055 RED FRESNEL LEN Ø155mm PLASTIC 1030.00186 ORANGE FRESNEL LEN Ø155mm PLASTIC 1030.00211 GREEN FRESNEL LEN Ø155mm PLASTIC 1030.00213 WHITE FRESNEL LEN Ø155mm PLASTIC AISI 316L STAINLESS STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 20 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 21. MEdium intensity and loW intensity MULTILED System AIRCRAFT warning lights Ex Lighting Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) - Safe area Classification: Group II - Category 2G 2D MIOL - LIOL OBSTRUCTION WARNING LIGHTS ATEX 94/9/EC EXECUTION INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE INTERNATIONAL REGULATIONS COMPLIANCY FOR VISUAL AIDS GOST-R (RTR / RTN) ZONE 1 / 2 - ZONE 21 / 22 safe area 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C ZONE 1 / 2 - ZONE 21 / 22 safe area II 2 G Ex d IIC T6/T2 II 2 D Ex tD A21 T80°C / T290°C GOST-K 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C ZONE 1 / 2 - ZONE 21 / 22 safe area IP66 IP66 IP66 INERIS 01 ATEX 0054X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 ICAO International Standards and Recommended Practices: Aerodromes - Annex 14 - Volume 1 - 4th Edition (November 2004) Charapter 6 : Medium Intensity Type B Flashing obstacle light MIOL-B Charapter 6 : Low Intensity Type A-B Steady burning obstacle light LIOL-A / LIOL-B FAA Advisor Circular AC150/5345-43F E.B.#67 - Lamp type MIOL-B / LIOL-A / LIOL-B Mechanical characteristics Body Painting Marine grade copper free aluminium High-temperature resistant borosylicate glass (zone 1/2 - 21/22 version) Transparent polycarbonate u/v resistant (safe area version) External epoxy powders grey ral-9006 colour Screws External stainless steel Gaskets Silicon rubber Cable Entry 3/4" Npt size threaded Globe Electrical characteristics Leds separate groups with individual led protection system - led technology stalilized by constant current generator Consumption LIOL-B = 4,8w (single and dual) / miol-B = 30w (single) - 60w (dual) Medium intensity (MIOL) flashing light with intensity 2000 cd (+/-25%) flashing 40 flash/minute Low intensity (LIOL) steady burning with intensity 32 cd (flashing on request) Realization single group leds system with own reflector dual groups leds system, each group with own reflector (1 main + 1 reserve) Optical characteristics Horizontal beam radiation 360° (miol / liol) Vertical beam radiation liol = between 5° and 10° / miol = 3° Efficency > 91% - pfc factor 0,99 Expetancy life long life time - more than 10 years Apply to: Flare - Airport - Stacks - High buildings - Chimneys - Tower crane - Pipelines - Bridges - Radio and Television towers Transmission lines - Wind turbines - Radar - and so on On request accessories: •Stainless steel wire protection guard •Aircraft Warning Lights and control panel support manufactured in according to customer specification •External painting colour on request •Threaded cable entry different than standard •Control panel with simultaneous or catenary multilight flashing system Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 21 MIOL - LIOL Explosion Proof Electrical Equipment
  • 22. MIOL - LIOL Ex Lighting MIOL - LIOL Technical data LED LAMP GROUP CODE VISUAL AIDS TYPES FLASHING [x/min.] EXECUTION TEMPERATURE TEMPERATURE CLASS (GAS) CLASS (DUSTS) CABLE ENTRIES DETAIL 1 x 3/4" B Low Intensity Obstruction warning lights LIOL-A-S > 10 cd x 1 LIOL-A-D RED FIXED > 10 cd x 2 LIOL-B-S RED FIXED > 32 cd x 1 LIOL-B-D RED FIXED > 32 cd x 2 RED FIXED Ex-d - T6 T80°C IP66 - - - 2 x 3/4" D Ex-d T6 T80°C 1 x 3/4" B IP66 - - - 2 x 3/4" D Ex-d T6 T80°C 1 x 3/4" B IP66 - 2 x 3/4" D T6 T80°C 1 x 3/4" B IP66 - - Ex-d - - 2 x 3/4" D MEDIUM Intensity Obstruction warning lights MIOL-A-S = 20.000 cd x 1 WHITE FLASHING 40 IP66 - - 2 x 3/4" C MIOL-A-D = 20.000 cd x 2 WHITE FLASHING 40 IP66 - - 2 x 3/4" C MIOL-B-S = 2.000 cd x 1 RED FLASHING 40 Ex-d T6 T80°C 1 x 3/4" A RED FLASHING = 2.000 cd x 2 MIOL-B-D = 2.000 cd x 1 MIOL-C-S MIOL-C-D RED FIXED = 2.000 cd x 2 RED FIXED IP66 40 - - 2 x 3/4" C Ex-d T6 T80°C 1 x 3/4" A IP66 - - - 2 x 3/4" C Ex-d T6 T80°C 1 x 3/4" A IP66 - 2 x 3/4" C T6 T80°C 1 x 3/4" A IP66 - - Ex-d - - 2 x 3/4" C MIOL - LIOL Technical features MIOL Reference details MIOL A MIOL 260 LIOL Reference details B LIOL LIOL T DO NO S SOTT O TE E IR 310 315 (FIXING) DO NO NOT N N O D SE GI NE ER IO EN ENS T NE RG DO NO NOT N IO W H IL E E N E ED NON AP R S N SOTT O TE E IR ED NON AP R 151 (FIXING) 768 O RG W H IL E E N E EN W SO HIL TT E O EN OP RIRE AP W SO HIL TT E O D SE GI NE ER IO EN ENS T T DO NO EN P EN OP RIRE AP IS NE P IS IO 445 150 115,5 (FIXING) 135,5 270 275 (FIXING) Since 1961 22 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 23. MIOL Reference details C MIOL LIOL MIOL - LIOL Technical features Reference details D MIOL 150 240 MIOL LIOL LIOL LIOL 660 200 410 191 320 400 MIOL - LIOL Main rules for aircraft warning lights MAIN RULES FOR VISUAL AIDS ICAO Annex 14 - Aerodromes Vol. 1 - Chapter 6 / 10 (July 2004) • The marking and/or lighting of obstacles is intended to reduce hazards to aircraft by indicating the presence of the obstacles (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.1) • Marking (red-orange/white painting) is used for day time • Marking may be ommitted when the obstacle is lighted • A fixed obstacle above a horizontal surface should be marked and, if the aerodrome is used at night, lighted.. (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.1.4) • A system of preventive maintenance of visual aids shall be employed to ensure lighting and marking system reliability (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 10.4.2) • The reliability of installed lighting equipments shold not less than one year (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 10.4.6) • The number and arrangement of Low, Medium or High Intensity Obstacle Lights , at each level to be marked, shall be such that the object is indicated from every angle in azimuth • Where a light is shielded in any direction by another, additional light shall be provided (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.22) • The number of lights needed for each level depends on the outside diameter of the obstacle • The top lights should be placed sufficiently below the top, so as to minimize contamination by smoke, powders, and so on.. (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.12) AWL TYPES (Aircraft Warning Lights) LIOL-A / B Low Intensity Obstacle Lights on fixed objects, Type-A / Type-B, shall be steady burning RED lights (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.23) MIOL-A Medium Intensity Obstacle Lights on fixed objects, Type-A , shall be flashing WHITE lights MIOL-B Medium Intensity Obstacle Lights on fixed objects, Type-B , shall be flashing RED lights MIOL-C Medium Intensity Obstacle Lights on fixed objects, Type-C , shall be steady burning RED lights (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.30) MIOL-A / MIOL-B Medium Intensity Obstacle Lights Type-A / Type-B, located on an obstacle, shall be flash simultaneously (ICA: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.32) HIOL-A / B High Intensity Obstacle Lights on fixed objects, Type-A / Type-B, shall be flashing WHITE lights (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.33) HIOL-A High Intensity Obstacle Lights Type-A, located on an obstacle, shall be flash simultaneously (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.35) HIOL-B High Intensity Obstacle Lights Type-B, indicating the presence of tower supporting overhead wires, an others.. shall be flash sequentially (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.36) Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 23 MIOL - LIOL Ex Lighting
  • 24. MIOL - LIOL Ex Lighting MIOL - LIOL Indicative diagram to obstruction light selection OBSTACLE ELEVATION > 45 m NO NO MARKED STRUCTURE (1) YES MARKED STRUCTURE (1) LIOL-A LIOL-B EXTENDED YES > 150 m VERTICAL STRUCTURE TYPE YES MIOL-B + LIOL-B MIOL-C NO YES LEGEND (1) DUAL MIOL-A/B MIOL-A DUAL MIOL-A/C DAY: HIOL-A + NIGHT: MIOL-B DAY: HIOL-A NIGHT: HIOL-A DAY: HIOL-A + NIGHT: MIOL-C DAY: MIOL-A + NIGHT: MIOL-B DAY: MIOL-A NIGHT: MIOL-A DAY: MIOL-A + NIGHT: MIOL-C Medium intensity obstruction light - TYPE A MIOL-B DUAL HIOL-A/C Low intensity obstruction light - TYPE B MIOL-A HIOL-A Low intensity obstruction light - TYPE A LIOL-B DUAL HIOL-A/B painted obstacle in acc. to icao directive LIOL-A NO Medium intensity obstruction light - TYPE B MIOL-C Medium intensity obstruction light - TYPE C HIOL-A High intensity obstruction light - TYPE A HIOL-B High intensity obstruction light - TYPE B MIOL - LIOL Polar diagrams – photometric data LIOL 32cd - Polar LIOL 32cd - CARTESIAN Flux 76.52 Im Maximum 69.78 cd Position H=-35.00 V=5.00 Efficiency: 100.00% MIOL 2000cd - Polar Flux 76.52 Im Maximum 69.78 cd Position H=-35.00 V=5.00 Efficiency: 100.00% Flux 1864.58 Im Maximum 4301.23 cd Position H=80.00 V=-90.00 Efficiency: 100.00% asymmetric VH asymmetric VH Flux 1864.58 Im Maximum 4301.23 cd Position H=80.00 V=-90.00 Efficiency: 100.00% asymmetric VH VH Planes VH Planes MIOL 2000cd - Cartesian VH Planes asymmetric VH VH Planes H Angles H Angles MIOL - LIOL On request accessories CODE DESCRIPTION MATERIAL 20302.0074 EVAC 100 / 101 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0077 EVAC 500 / 501 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0037 EVAC 100 / 101 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL 20302.0040 EVAC 500 / 501 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL CONTROL PANEL WITH SIMULTANEOUS OR CATENARY MULTILIGHT FLASHING SYSTEM ALUMINIUM / PAINTED STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 24 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 25. FLOODLIGHTS FOR HALOGEN AND DISCHARGE LAMPS Explosion Proof Electrical Equipment SFDE Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D FLOODLIGHT / PROJECTOR ATEX 94/9/EC EXECUTION INSTALLATION GOST-K 1Ex de IIB T6 (T3…T2) DIP A21 TA (200…230) °C 1Ex de IIB T6 (T3…T2) DIP A21 TA (200…230) °C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 PROTECTION DEGREE ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0018 POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 CERTIFICATE REF. RULES OF COMPLIANCE GOST-R (RTR / RTN) II 2 G Ex d / Ex de IIB T3/T2 II 2 D Ex tD A21 T200°C / T229°C Mechanical characteristics Body marine grade copper free aluminium Diffuser tempered front glass support adjustable type hot dip galvanized steel reflector internal polished aluminium painting external epoxy powders grey ral-9006 colour screws external stainless steel gaskets silicon rubber cable entry 3/4” npt size threaded Electrical characteristics Power supply conventional ballast 230v - 50hz (p.f.corrected - cos ρ ≥ 0,95) lampholders porcelain e40 size internal wiring high-temperature resistant silicon rubber insulation cables terminals suitable up to 4mm/sq cables On Request Accessories: • External painting colour on request • Control gear with voltage supply different than standard • Threaded cable entry different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 25 SFDE Ex Lighting
  • 26. Ex Lighting SFDE Technical data POWER LAMP SFDE CODE TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY SIZE DETAIL 2 x ISO-M20 A FLOODLIGHTS FOR HALOGEN LAMP - POWER SUPPLY 230V-50Hz SFDE500IA 500 W T2 T 229°C E-40 FLOODLIGHTS FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V-50Hz SFDE150HPNA 150 W T4 T 200°C E-40 2 x ISO-M20 A SFDE250HPNA 250 W T4 T 200°C E-40 2 x ISO-M20 A SFDE400HPNA 400 W T3 T 200°C E-40 2 x ISO-M20 A FLOODLIGHTS FOR METAL HALIDE LAMP - POWER SUPPLY 230V-50Hz SFDE250MH 250 W T4 SFDE400MH 400 W T3 T 200°C E-40 2 x ISO-M20 A T 200°C E-40 2 x ISO-M20 A SFDE Technical features CODE A [mm] B [mm] C [mm] D [mm] E [mm] SFDE150HPNA 485 425 290 270 504 F [mm] 88 WEIGHT [Kg] CABLE ENTRY 25,00 2 x ISO-M20 DETAIL A SFDE250HPNA 485 425 290 270 504 88 25,00 2 x ISO-M20 A SFDE400HPNA 485 425 290 270 504 88 25,00 2 x ISO-M20 A SFDE250MH 485 425 290 270 504 88 25,00 2 x ISO-M20 A SFDE400MH 485 425 290 270 504 88 25,00 2 x ISO-M20 A SFDE500 IA 485 425 290 270 504 88 21,00 2 x ISO-M20 A Reference details A F C E B D A 2 x ISOM20 2 x ISOM20 110 110 110 110 SFD250HPS SFD400MH SFD500IA REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 26 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 27. FLOODLIGHTS FOR INCANDESCENT AND DISCHARGE LAMPS Explosion Proof Electrical Equipment RCDE Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D FLOODLIGHT / PROJECTOR ATEX 94/9/EC EXECUTION GOST-R (RTR / RTN) GOST-K 1Ex d IIC T4/T3/T X DIP A21 TA 200°C, DIP A21 TA (135, 160, 200, 230)°C 1Ex d IIC T4/T3/T2 X DIP A21 TA (135, 160, 200, 230)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 03 ATEX 0004 X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T4/T3/T2 II 2 D Ex tD A21 T135°C/T160°C T200°C/T230°C INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE CONTROL GEAR ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C 1Ex d IIC T6 (T5…T2) X DIP A21 TA (80…290)°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0054X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T6/T2 II 2 D Ex tD A21 T80°C/T290°C EXECUTION INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body marine grade copper free aluminium Diffuser tempered front glass Support adjustable type hot dip galvanized steel Reflector internal polished aluminium Painting external epoxy powders grey ral-9006 colour Screws external stainless steel Gaskets silicon rubber Cable entry 3/4” npt size threaded Electrical characteristics Power supply conventional ballast 230V - 50Hz (p.f.corrected - cos ρ ≥ 0,95) Lampholders porcelain E40 size Internal wiring high-temperature resistant silicon rubber insulation cables Terminals suitable up to 4mm/sq cables On Request Accessories: • External painting colour on request • Control gear with voltage supply different than standard • Threaded cable entry different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 27 RCDE Ex Lighting
  • 28. Ex Lighting RCDE Technical data TEMPERATURE CLASS (GAS) LAMP TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY SIZE DETAIL 1x3/4” A 1x3/4” A FLOODLIGHTS FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz RECDE500 500 W T2 RECDE500 500 W T 230°C E-40 FLOODLIGHTS FOR BLENDED LIGHT LAMP - POWER SUPPLY 230V-50Hz T3 T 200°C E-40 FLOODLIGHTS FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V-50Hz RECDE500 250HG 250 W T3 T 160°C E-40 3x3/4” B RECDE500 400HG 400 W T3 T 200°C E-40 3x3/4” B FLOODLIGHTS FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V-50Hz RECDE500 250HPNA 250 W T4 RECDE500 400HPNA 400 W T3 T 135°C 3x3/4” B T 200°C E-40 E-40 3x3/4” B FLOODLIGHTS FOR METAL HALIDE LAMP - POWER SUPPLY 230V-50Hz RECDE500 250MH 250 W T4 T 135°C E-40 3x3/4” B RECDE500 400MH 400 W T3 T 200°C E-40 3x3/4” B WEIGHT [Kg] CABLE ENTRY DETAIL RCDE Technical features CODE A [mm] RECDE500 RECDE500 250HG 542 542 B [mm] C [mm] D [mm] 378 378 376 406 - 700 21,00 29,00 1 x 3/4” 3 x 3/4” A B RECDE500 250HPNA 542 378 406 700 29,50 3 x 3/4” B RECDE500 400HG 542 378 406 700 31,00 3 x 3/4” B RECDE500 400HPNA 542 378 406 700 31,50 3 x 3/4” B RECDE500 250MH 542 378 406 700 26,50 3 x 3/4” B RECDE500 400MH 542 378 406 700 31,50 3 x 3/4” B B 1x3/4” 1x3/4” 2x3/4” with PLG2 B A D A B A RCDE CODE C RCDE250MH 220 220 C RCDE250HG RCDE250HPS REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 28 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 29. Explosion Proof Electrical Equipment Ex Lighting EVO - EVT - TLF Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D PORTHOLE LIGHTING FIXTURE (EVO) ATEX 94/9/EC EXECUTION GOST-R (RTR / RTN) GOST-K 1Ex d IIC T3 X, DIP A21 TA 200°C 1Ex d IIC T3 X, DIP A21 TA 200°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0039 X POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T3, INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE II 2 D Ex tD A21 T200°C LIGHTING FIXTURE (EVT) ATEX 94/9/EC EXECUTION GOST-R (RTR / RTN) GOST-K 1Ex d IIC T4, DIP A21 TA 135°C 1Ex d IIC T4, DIP A21 TA 135°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 INERIS 01 ATEX 0040 POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIC T4, INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE II 2 D Ex tD A21 T135°C LIGHTING FIXTURE (TLF) ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K II 2 G Ex d / Ex de IIB T3 II 2 D Ex tD A21 T200°C 1Ex d IIB T3, 2Ex de IIB T3 DIP A21 TA 200°C 1Ex d IIB T3, 2Ex de IIB T3 DIP A21 TA 200°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP65 IP65 IP65 INERIS 01 ATEX 0026 POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 EXECUTION INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body marine grade copper free aluminium diffuser borosilicate frontal glass (evt) diffuser tempered frontal glass (evo - tlf) painting external epoxy powders grey ral-9006 colour screws external stainless steel gaskets silicon rubber cable entry 3/4” npt size threaded protection guard galvanized wire steel (evt only) Electrical characteristics Power supply standard voltage 230v - 50hz lampholders porcelain e27 size internal wiring high-temperature resistant silicon rubber insulation cables On Request Accessories: • External painting colour on request • Threaded cable entry different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 29 EVO - EVT - TLF LIGHTING FIXTURES FOR INCANDESCENT LAMPS
  • 30. EVO – EVT - TLF Technical data CODE LAMP TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY SIZE DETAIL LIGHTING FIXTURE FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz EVO100 100 W T3 EVT100 100 W T4 TLF100 100 W T3 T 200°C E-27 1x3/4” T135°C E-27 2x3/4” B T 200°C E-27 2x3/4” C A EVO – EVT - TLF Technical features CODE A [mm] B [mm] C [mm] WEIGHT [Kg] CABLE ENTRY DETAIL EVO100 Ø140 185 Ø162 2,00 1 x 3/4” A EVT100 Ø233 180 155 4,00 2 x 3/4” B TLF100 309 127 165 3,00 2 x 3/4” C Reference details 1 x 3/4” B Ø C A C 2 x 3/4” B B ØA A C A C 2 x 3/4” B EVO - EVT - TLF Ex Lighting REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 30 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 31. LIGHTING FIXTURES FOR HIGH EFFICENCY LED LAMPS AND FLUORESCENT TUBE LAMPS Explosion Proof Electrical Equipment EXL Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURE ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex d IIB T6, 1Exd [ia/ib] IIB T6, DIP A21 TA 85°C 1Ex d IIB T6, 1Exd [ia/ib] IIB T6, DIP A21 TA 85°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 IMQ 09 ATEX 020 POCC IT. ГБ05.B02537 No. 07/43-269 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 ГОСТ Р 51330.9-99 (МЭК 660079-10-95) ГОСТ Р 51330.13-99 (МЭК 660079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex d IIB T6 II 2 D Ex tD A21 T85°C EXECUTION INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body marine grade copper free aluminium Diffuser high-temperature resistant borosylicate glass painting external epoxy powders grey ral-9006 colour screws external stainless steel reflectors white stove enamelled sheet steel cable entry 3/4” npt size threaded c/w cable gland Electrical characteristics Power supply lampholders internal wiring elettronic ballast 220V/240V - 50/60Hz (p.f.corrected - cos ρ ≥ 0,98) bi-pin G5 cap (fluorescent lamp only) high-temperature resistant silicon rubber insulation cables terminals suitable up to 4mm/sq cables emergency unit emergency unit with inverter charger and Ni-Cd battery pack see technical features for more details Functional characteristics · EXL08ESA (Always ON - Maintained): 8W fluorescent lamp and electronic ballast 230V AC and emergency unit 3.6 V - 2Ah for an autonomy of 2 hours 3.6 V - 4Ah for an autonomy 3 hours · EXL08E (Emergency only - Maintained): 8W fluorescent lamp and emergency unit 3.6 V - 2Ah with autonomy 3 hours · EXL08L (Network only - Not Maintained): with high brightness LEDs (350mA - 4,8 W) Supply from 120V to 240V AC / DC · EXL08LE (Emergency only - Maintained): with high brightness LEDs (350mA - 4,8 W) 220/240V AC and emergency unit 6V - 2Ah for an autonomy of 3 hours complete with charge status monitor LED system (RED: battery under charging – GREEN: battery loaded) Remarks · EXL08E / EXL08ESA - 8W fluorescent lamp: emergency light intensity is 40% of light intensity with networking power supply · EXL08LE - with high brightness LEDs (350mA -4.8 W): emergency light intensity is 100% of light intensity with networking power supply On Request Accessories: • External painting colour on request • Electronic ballast with voltage supply different than standard • Threaded cable entry different than standard • Self-adhesive green label with EXIT sign (language on request) Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 31 EXL Ex Lighting
  • 32. Ex Lighting EXL Technical data POWER SUPPLY LAMP mA (LED) TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) EMERGENCY UNIT AUTONOMY LIGHTING FIXTURES FOR FLUORESCENT TUBE LAMPS EXL08 220 ÷ 240V AC 8W - T6 T 85°C - - EXL08E-3 220 ÷ 240V AC 8W - T6 T 85°C 3,6V - 4A/h 3h EXL08ESA-3 220 ÷ 240V AC 8W - T6 T 85°C 3,6V - 4A/h 3h EXL08L 120 ÷ 240V AC/DC 4,8 W 350 T6 T 85°C - - EXL08LE 220 ÷ 240V AC 4,8 W 350 T6 T 85°C 3,6V - 2A/h 3h EXL208L 120 ÷ 240V AC/DC 9,16 W 350 T6 T 85°C - - LIGHTING FIXTURES FOR HIGH EFFICENCY LED LAMPS EXL Technical features E [mm] WEIGHT [Kg] CABLE ENTRY DETAIL EXL08 CODE A [mm] 380 B [mm] 170 C [mm] 125 D [mm] 370 125 8,00 1 x 3/4” A EXL08E-3 380 170 125 370 125 8,00 1 x 3/4” A EXL08ESA-3 380 170 125 370 125 8,00 1 x 3/4” A EXL08L 380 170 125 370 125 8,00 1 x 3/4” A EXL08LE 380 170 125 370 125 8,00 1 x 3/4” A EXL208L 380 170 125 370 125 8,00 1 x 3/4” A Reference details A A C E B EXL CODE D 3/4" EXL On request accessories CODE DESCRIPTION EXL-08 MATERIAL SELF-ADHESIVE GREEN “EXIT” LABEL 2070.00088 POLYESTER EXL-08L EXL2-08L REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 32 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 33. LIGHTING FIXTURES FOR FLUORESCENT TUBE LAMPS Explosion Proof Electrical Equipment EVG Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D 18W LIGHTING FIXTURE ATEX 94/9/EC GOST-R (RTR / RTN) 2Ex edq IIC T4 (T6) DIP A21 TA 80°C II 2 G Ex edq IIC T4 II 2 D Ex tD A21 T 80°C EXECUTION AMBIENT TEMPERATURE 36W LIGHTING FIXTURE ATEX 94/9/EC II 2 G Ex edq IIC T4 II 2 D Ex tD A21 T 80°C -20°C ÷ +60°C -20°C ÷ +60°C IP66 IP66 IP66/64 PTB 97 ATEX 2223 POCC DE. ГБ05.B01788 PTB 07 ATEX 2040 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 ГОСТ Р 51330.9-99 (МЭК 660079-10-95) ГОСТ Р 51330.13-99 (МЭК 660079-14-96) ГОСТ Р МЭК 61241-3-99 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE LIGHTING FIXTURES WITH EMERGENCY UNIT ONLY 58W LIGHTING FIXTURE ATEX 94/9/EC GOST-R (RTR / RTN) II 2 G Ex edq IIC T4 II 2 D Ex tD A21 T 90°C EXECUTION AMBIENT TEMPERATURE -20°C ÷ +55°C 2Ex edq IIC T4 (T6) DIP A21 TA 90°C ATEX 94/9/EC II 2 GD Ex edq IIC T4 T80°C -20°C ÷ +60°C -20°C ÷ +60°C IP66 IP66 IP66/64 PTB 97 ATEX 2225 POCC DE. ГБ05.B01788 PTB 05 ATEX 2066 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 ГОСТ Р 51330.9-99 (МЭК 660079-10-95) ГОСТ Р 51330.13-99 (МЭК 660079-14-96) ГОСТ Р МЭК 61241-3-99 EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE -20°C ÷ +55°C Mechanical characteristics Body glass fibre reinforced polyester resin diffuser u/v resistant polycarbonate - hinged to body safety closing operated by triangular key gaskets epdm rubber suitable for high temperatures and resistant to enviroments conditions internal reflector white polyester highly refractor diffuser cable entry iso-metric thread c/w plastic cable glands and stopping plug Electrical characteristics Power supply elettronic ballast 220v/240v - 50/60hz (p.f.corrected - cos ρ ≥ 0,98) lampholders bi-pin g13 cap internal wiring high-temperature resistant silicon rubber insulation cables terminals suitable up to 6mm/sq cables safety feature emergency unit “end of life” switching-off system in according to en 60079-7 rules emergency unit composed of inverter charger and ni-cd battery pack 7a/h 6v autonomy up to 180 min. advantages see table “advantage features” On Request Accessories: •Pole mounting kit complete with stainless steel hardware •Ceiling mounting kit complete with stainless steel hardware •Pendant mounting kit complete with stainless steel hardware •Wall/Structure mounting kit complete with stainless steel hardware •Electronic ballast with voltage supply different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 33 EVG Ex Lighting
  • 34. Ex Lighting EVG Technical data LAMP EVG CODE TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE ENTRY EMERGENCY UNIT AUTONOMY DETAIL FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50/60Hz SH-21EVG 1 x 18W T4 (Ta = -20°C / +60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 - - A SH-41EVG 1 x 36W T4 (Ta = -20°C / +60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 - - A SH-61EVG 1 x 58W T4 (Ta = -20°C / +60°C) T 90°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 - - A SH-22EVG 2 x 18W T4 (Ta = -20°C / +60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 - - A SH-42EVG 2 x 36W T4 (Ta = -20°C / +60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 - - A SH-62EVG 2 x 58W T4 (Ta = -20°C / +60°C) T 90°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 - - A EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50/60Hz SH-22EVG-E 2 x 18W T4 (Ta = -20°C / +60°C) T 80°C (Ta = -20°C / +60°C) G13 2 x ISO-M25 6 V - 7 A/h 3h B SH-42EVG-E 2 x 36W T4 (Ta = -20°C / +60°C) T 80°C (Ta = -20°C / +60°C) G13 2 x ISO-M25 6 V - 7 A/h 3h B EVG Technical features CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL SH-21EVG 786 160 214 600 10,00 3 x ISO-M25 A SH-41EVG 1355 150 226 716 13,00 3 x ISO-M25 A SH-61EVG 1696 160 214 800 16,00 3 x ISO-M25 A SH-22EVG 786 160 214 600 10,50 3 x ISO-M25 A SH-42EVG 1355 150 226 716 13,50 3 x ISO-M25 A SH-62EVG 1696 160 214 800 16,50 3 x ISO-M25 A SH-22EVG-E 913 160 221 600 9,40 2 x ISO-M25 B SH-42EVG-E 1523 160 221 800 12,80 2 x ISO-M25 B Reference details A B D C A B B D C A Since 1961 34 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 35. Ex Lighting EVG Installation and mounting details type 1 type 2 Wall/structure mounting type 3 type 4 00 Pendant mounting EVG Ceiling mounting Pole mounting Assemblig detail with pole (typical) 1 50 100 45° EVG Polar diagrams – photometric data SH-21EVG SH-22EVG SH-41EVG Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 35
  • 36. Ex Lighting EVG Polar diagrams – photometric data SH-61EVG SH-62EVG EVG SH-42EVG EVG with emergency unit LIGHTING FIXTURES AND EMERGENCY UNIT ELECTRICAL DESIGN AND SPECIAL FEATURES Microprocessor (plc) “end-of life” switching-off system at the end of life a fluorescent tube lamp is safely switched off (according to iec en-60079-7 stds) Multi-function led multi-function led indcator with coded indication of the functions, status and potential failures of the electronic device and of the batteries Monitoring special signal whenever there is a e.o.l. situation (led red flashing ) automatic weekly functions test automatic annual 2/3 times operating period test function and operating period test can be done manually also Maintenance quick replacement of battery set even in explosive atmosphere presence electrical disconnection whenever the batteries box is opened 24h max recharging time (in according to en-60598-2-22) Safety Highest degree of safety in case of lamp failure during the emergency light operation In case of lamp failure during emergency operation the second tube lamp will automatically take over the emergency operation (two lamps version only) EVG On request accessories CODE DESCRIPTION INSTALLATION MATERIAL 20301.0162 POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0163 POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0165 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 STAINLESS STEEL 20302.0121 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 GALVANIZED STEEL 20302.0128 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 36 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 37. FLUORESCENT LIGHTING FIXTURES FOR CEILING OR RECESSED INSTALLATION Ex Lighting e191 - e192 Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURE ATEX 94/9/EC II 2G Ex edq IIC T4 II 2D Ex tD A21 T 80°C EXECUTION AMBIENT TEMPERATURE GOST-R (RTR / RTN) 2Ex edq IIC T4, 2Ex eq II T4, DIP A21 TA 80°C -20°C ÷ +60°C (e191… - e192... surface/recessed in suspend. ceiling) -20°C ÷ +50°C (e191… recessed mount. insulated) -20°C ÷ +40°C (e192... recessed mount. insulated) PROTECTION DEGREE -20°C ÷ +40°C IP65 IP65 IBExU 04 ATEX 1062 POCC DE. ГБ05.B01788 EN 50014 +A1 +A2; EN 50017; EN 50018; EN 50019; EN 50281-1-1 ГОСТ Р 51330.9-99 (МЭК 660079-10-95) ГОСТ Р 51330.13-99 (МЭК 660079-14-96) ГОСТ Р МЭК 61241-3-99 CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body sheet steel white coloured ral 9016 diffuser safety toughened impact resistant tempered glass hinged to body safety closing central locking system operated by 5mm allen key - hinges on opposite side gaskets epdm rubber suitable for high temperatures and resistant to enviroments conditions internal reflector high anodized purest aluminium cable entry iso-metric thread c/w plastic cable glands and stopping plug Electrical characteristics Power supply dual channel elettronic ballast 220v/240v-50/60hz (p.f.corrected - cos ρ ≥ 0,98) - DC lampholders bi-pin g13 cap internal wiring high-temperature resistant silicon rubber insulation cables terminals suitable up to 6mm/sq cables isolating switch switching off all poles when lighting fitting is opened showing the actual position by optical indicator Safety feature “END OF LIFE” switching-off system in according to EN 60079-7 rules On Request Accessories: •Recessed mounting kit EB182 series complete with stainless steel hardware •Stainless steel sheet body •Electronic ballast with voltage supply different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 37 e191- e192 Explosion Proof Electrical Equipment
  • 38. e191 - e192 Technical data CODE TEMPERATURE CLASS (GAS) LAMP TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE ENTRY DETAIL FLUORESCENT LIGHTING FIXTURES - POWER SUPPLY 220-240V-50/60Hz - DC e19121 1 x 18W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19122 2 x 18W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19141 1 x 36W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19142 2 x 36W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19161 1 x 58W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19162 2 x 58W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19223 3 x 18W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19224 4 x 18W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19243 3 x 36W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19244 4 x 36W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19263 3 x 58W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e19264 4 x 58W T4 (Ta = -20°C ÷ 40/50/60°C) T 80°C (Ta = -20°C / +60°C) G13 3 x ISO-M25 A e191 - e192 Lighting fixture technical features CODE A [mm] B [mm] C [mm] D [mm] E [mm] WEIGHT [Kg] CABLE ENTRY DETAIL e19121 720 82 368 600 404 10,00 3 x ISO-M25 A e19122 720 82 368 600 404 10,00 3 x ISO-M25 A e19141 1330 82 368 1200 404 15,50 3 x ISO-M25 A e19142 1330 82 368 1200 404 15,50 3 x ISO-M25 A e19161 1630 82 368 1400 404 18,00 3 x ISO-M25 A e19162 1630 82 368 1400 404 18,00 3 x ISO-M25 A e19223 720 82 500 600 536 18,50 3 x ISO-M25 A e19224 720 82 500 600 536 18,50 3 x ISO-M25 A e19243 1330 82 500 1200 536 25,50 3 x ISO-M25 A e19244 1330 82 500 1200 536 25,50 3 x ISO-M25 A e19263 1630 82 500 1400 536 28,50 3 x ISO-M25 A e19264 1630 82 500 1400 536 28,50 3 x ISO-M25 A Lighting fixture Reference details A E Ø9 D B e191- e192 e192 e191- Ex Lighting C A Since 1961 38 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 39. e191 - e192 Recessed frame technical features CODE LUMINARIE TYPE EB182-18 e19121 388 740 786 93 300 434 82 9 e19122 388 740 786 93 300 434 82 9 EB182-36 e19141 388 1350 1396 98 400 434 82 9 e19142 388 1350 1396 98 400 434 82 9 e19161 388 1650 1696 48 400 434 82 9 EB182-58 A [mm] B [mm] C [mm] D [mm] E [mm] F [mm] G [mm] H [mm] e19162 388 1650 1696 48 400 434 82 9 EB192-18 e19223 520 740 786 93 300 566 82 9 e19224 520 740 786 93 300 566 82 9 EB192-36 e19243 520 1350 1396 96 400 566 82 9 e19244 520 1350 1396 96 400 566 82 9 EB192-58 e19263 520 1650 1696 48 400 566 82 9 e19264 520 1650 1696 48 400 566 82 9 Recessed frame Reference details B G A H F C D E E E D e191 - e192 Polar diagrams – photometric data e191-42 e192-43 e192-44 Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 39 e191- e192 Ex Lighting
  • 40. e191- e192 Ex Lighting e191 - e192 Polar diagrams – photometric data e191-22 e191-23 e191-64 e191 - e192 On request accessories CODE DESCRIPTION MATERIAL EB182-18 RECESSED FRAME FOR LIGHTING FIXTURE 1x18W AND 2x18W PAINTED SHEET STEEL EB182-36 RECESSED FRAME FOR LIGHTING FIXTURE 1x36W AND 2x36W PAINTED SHEET STEEL EB182-58 RECESSED FRAME FOR LIGHTING FIXTURE 1x58W AND 2x58W PAINTED SHEET STEEL EB192-18 RECESSED FRAME FOR LIGHTING FIXTURE 3x18W AND 4x18W PAINTED SHEET STEEL EB192-36 RECESSED FRAME FOR LIGHTING FIXTURE 3x36W AND 4x36W PAINTED SHEET STEEL EB192-58 RECESSED FRAME FOR LIGHTING FIXTURE 3x58W AND 4x58W PAINTED SHEET STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 40 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 41. INCREASED SAFETY LIGHTING FIXTURES FOR BI-PIN FLUORESCENT LAMPS Explosion Proof Electrical Equipment AVF Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURE ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 2Ex ed IIC T5 DIP A21 TA 70°C 2Ex ed IIC T5 DIP A21 TA 70°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 KEMA 01 ATEX 2069 POCC IT. ГБ05.B02536 No. 07/43-269 EN 60079-0; EN 60079-1; EN 60079-7; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex ed IIC T5 II 2 D Ex tD A21 T70°C EXECUTION INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE EMERGENCY UNIT ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K 1Ex ed IIB T6 DIP A21 TA 85°C 1Ex ed IIB T6 DIP A21 TA 85°C ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 IP66 IP66 IP66 IMQ 08 ATEX 026X POCC IT. ГБ05.B02537 No. 07/43-269 EN 60070-0; EN 60079-7; EN 61241-0; EN 61241-1; ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 II 2 G Ex ed IIC T6 II 2 D Ex tD A21 T85°C EXECUTION INSTALLATION PROTECTION DEGREE CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body galss fibre reinforced polyester resin self-extinguishing acc. to UL94 Diffuser U/V resistant polycarbonate - hinged to body Safety closing operated by hexagonal key Gaskets EPDM 60 rubber suitable for high temperatures and resistant to enviroments conditions Internal reflector white stove enamelled sheet aluminum Cable entry ISO-Metric complete with cable glands and plug Electrical characteristics Power supply elettronic ballast 220V/240V 50/60Hz (p.f. corrected - cos ρ ≥ 0,98) Lampholders bi-pin G13 cap Internal wiring high-temperature resistant silicon rubber insulation cables Terminals suitable up to 6mm/sq cables Safety feature EEx de safety switch On Request Accessories: • Pole mounting kit complete with stainless steel hardware • Ceiling mounting kit complete with stainless steel hardware • Pendant mounting kit complete with stainless steel hardware • Wall/Structure mounting kit complete with stainless steel hardware • Electronic ballast with voltage supply different than standard • AUTOTEST electronic system for emergency unit Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 41 AVF Ex Lighting
  • 42. Ex Lighting AVF Technical data LAMP AVF CODE TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) CABLE ENTRY LAMPHOLDER EMERGENCY UNIT AUTONOMY DETAIL FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V 50/60Hz AVF 118 1 x 18W T5 T 70°C G13 3 x M20 x 1,5 - - A AVF 136 1 x 36W T5 T 70°C G13 3 x M20 x 1,5 - - A AVF 218 2 x 18W T5 T 70°C G13 3 x M20 x 1,5 - - A AVF 236 2 x 36W T5 T 70°C G13 3 x M20 x 1,5 - - A EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V 50/60Hz AVF 118-E 1 x 18W T5 T 70°C G13 2 x M20 x 1,5 4.8 V - 4Ah 3h B AVF 136-E 1 x 36W T5 T 70°C G13 2 x M20 x 1,5 4.8 V - 4Ah 3h B AVF 218-E 2 x 18W T5 T 70°C G13 2 x M20 x 1,5 4.8 V - 4Ah 3h B AVF 236-E 2 x 36W T5 T 70°C G13 2 x M20 x 1,5 4.8 V - 4Ah 3h B AVF Technical features A [mm] B [mm] WEIGHT [Kg] CABLE ENTRY DETAIL AVF 118 CODE 730 215 160 400 6,00 3 x M20 x 1,5 A AVF 136 1340 215 160 450 6,50 3 x M20 x 1,5 A AVF 218 730 215 160 400 7,00 3 x M20 x 1,5 A AVF 236 1340 215 160 450 7,50 3 x M20 x 1,5 A CODE C [mm] C [mm] D [mm] A [mm] B [mm] WEIGHT [Kg] CABLE ENTRY DETAIL AVF 118-E 925 215 280 D [mm] 400 11,00 2 x M20 x 1,5 B AVF 136-E 1535 215 280 450 11,50 2 x M20 x 1,5 B AVF 218-E 925 215 280 400 12,00 2 x M20 x 1,5 B AVF 236-E 1535 215 280 450 12,50 2 x M20 x 1,5 B Reference details A 8MA D 8MA C 8MA B B A 8MA D 8MA C 8MA B A Since 1961 42 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 43. Ex Lighting AVF Installation and mounting details Ceiling mounting Pendant mounting type 2 Wall/structure mounting type 3 type 4 0 10 AVF type 1 Pole mounting Assemblig detail with pole (typical) 50 100 45° AVF Polar diagrams – photometric data AVF218 AVF136 AVF236 Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 43
  • 44. Ex Lighting AVF with emergency unit (design and special features) AVF GENERALITY: The controller unit system permits to manage in AUTOTEST the verify of emergency unit working This system allows the emergency working of every fluorescent tube lamps (NON maintened working) The check and the control system has been realized by proper microprocessor which perform the following tests : - continuous test on the battery charger working, on the operation of the battery, and on presence of voltage supply - duration test in emergency working (every 3 months) with check of battery charge - test of emergency working (weekly) with check of right lamp operation Every information concerning the checks can be managed singly or tranmitted by “remote control system” in order to manage complete illumination system test in centralized way. Multicolor LED indicator in standard working (continuous led light) ON ON ON ON ON ON ON ON ON Regular operation ON ON ON ON ON ON ON ON ON Failed battery performance check OFF OFF OFF OFF OFF OFF OFF OFF OFF Lack of main power supply ON ON ON OFF ON ON ON OFF ON Lack of battery Multicolor LED indicator during test opetarion (intermittent led light) ON OFF ON OFF ON OFF ON OFF ON Performing lamp test ON ON OFF ON ON OFF ON ON OFF Performing battery pack test ON OFF ON OFF ON OFF ON OFF ON Failed lamp test Multicolor LED indicator during batteries recharging phase ON OFF ON OFF ON OFF ON OFF ON 24 hours ON ON ON ON ON ON ON ON ON After 24 hours AVF On request accessories CODE DESCRIPTION INSTALLATION MATERIAL 20301.0162 POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0163 POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0165 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 STAINLESS STEEL 20302.0121 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 GALVANIZED STEEL 20302.0128 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL AUTOTEST electronic system - - REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 44 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 45. Explosion Proof Electrical Equipment Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D Ex Lighting SFDQL FLOODLIGHT ATEX 94/9/EC II 2G Ex eq II T3 II 2D Ex tD A21 T 200°C EXECUTION -40°C ÷ +40°C -40°C ÷ +60°C AMBIENT TEMPERATURE PROTECTION DEGREE IP66 CERTIFICATE REF. IMQ 09 ATEX 014X RULES OF COMPLIANCE EN 60079-0; EN 60079-5; EN 60079-7; EN 61241-0; EN 61241-1 Mechanical characteristics Body marine grade copper free aluminum Diffuser tempered front glass Support steel bracket with rotation-proof system Reflector anodized and polished 99,85 pure aluminum internal optic Painting thermosetting polyester powder resistant to atmospheric agents and corrosion grey RAL 9006 colour Screws stainless steel Gaskets pure silicon heat resistance Cable entry iso-Metric complete with nikel plated brass cable gland M20 Electrical characteristics Power supply 180 ÷ 230V DC / 180 ÷ 277V AC x 165W - 55W - 85W Lamp long life induction lamp (60.000 hours) Terminals suitable up to 4mm/sq cables On Request Accessories: •Power supply 90 ÷ 120V AC/DC (55/85W only) Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 45 SFDQL FLOODLIGHT PROJECTORS FOR INDUCTION LAMPS
  • 46. Ex Lighting SFDQL SFDQL Technical data CODE TEMPERATURE CLASS (GAS) LAMP TEMPERATURE CLASS (DUSTS) CABLE ENTRY SIZE DETAIL FLOODLIGHT FOR INDUCTION LAMP - POWER SUPPLY 220V/240V 50/60Hz - 220V/240V DC - 120V AC/DC SFDQL-55JB 55W T3 (Ta = -40°C / +60°C) T 200°C 2 x ISO M20 A SFDQL-85JB 85W T3 (Ta = -40°C / +60°C) T 200°C 2 x ISO M20 A SFDQL-55 55W T3 (Ta = -40°C / +60°C) T 200°C 1 x PCE M20 B SFDQL-85 85W T3 (Ta = -40°C / +60°C) T 200°C 1 x PCE M20 B FLOODLIGHT FOR INDUCTION LAMP - POWER SUPPLY 220V/240V 50/60Hz - 220V/240V DC SFDQL-165JB 165W T3 (Ta = -40°C / +40°C) T 200°C 2 x ISO M20 A SFDQL-165 165W T3 (Ta = -40°C / +40°C) T 200°C 1 x PCE M20 B WEIGHT [Kg] CABLE ENTRY DETAIL SFDQL Technical features CODE A [mm] B [mm] C [mm] D [mm] SFDQL-55JB 430 460 545 260 8,50 2 x ISO M20 A SFDQL-85JB 430 460 545 260 8,70 2 x ISO M20 A SFDQL-165JB 430 460 545 260 9,50 2 x ISO M20 A SFDQL-55 430 460 545 180 8,00 1 x PCE M20 B SFDQL-85 430 460 545 180 8,20 1 x PCE M20 B SFDQL-165 430 460 545 180 9,00 1 x PCE M20 B Reference details A A D II 2G Ex eq II T3 II 2D Ex tD A21 IP 66 T200° C IMQ 08 ATEX 014X www.feam-ex.com INDUCTION LAMP SFDQL C B 0722 55W 85W 165W 55W-85W Ta -40° C / +60° C 180÷230V DC 180÷277V AC 90÷120V AC/DC 165W Ta -40° C / +40° C 2 X ISO M20 0° 12 155 155 Since 1961 46 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 47. Ex Lighting Reference details B A D II 2G Ex eq II T3 II 2D Ex tD A21 IP 66 T200° C IMQ 08 ATEX 014X www.feam-ex.com INDUCTION LAMP SFDQL B 0722 C 55W 85W 165W 55W-85W Ta -40° C / +60° C 180÷230V DC 180÷277V AC 90÷120V AC/DC 165W Ta -40° C / +40° C 155 0° 12 1 X PCE M20 155 SFDQL Polar diagrams – photometric data SFDQL55 SFDQL85 SFDQL165 Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 47 SFDQL SFDQL Technical features
  • 48. Ex Lighting SFDQL SFDQL On request accessories CODE DESCRIPTION 20303.0099 PROTECTION GRID 20303.0100 MATERIAL POLE ADAPTER - DIA. 40÷60mm Protection grid 20303.0099 ALUMINUM PAINTED STEEL Pole adapter 20303.0100 REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 48 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 49. LIGHTING FIXTURES FOR FLUORESCENT TUBE LAMPS Explosion Proof Electrical Equipment EVSN Installation: hazardous areas - Zone 2 (Gases) - Zone 22 (Dusts) Classification: Group II - Category 3G 3D LIGHTING FIXTURE EMERGENCY UNIT ATEX 94/9/EC ATEX 94/9/EC II 2 G Ex ed IIC II 2 D Ex tD A21 T85°C II 3 G Ex nA II T6/T5 II 3 D Ex tD A22 T85°C/T100°C EXECUTION AMBIENT TEMPERATURE ZONE 2 - ZONE 22 INSTALLATION -40°C ÷ +55°C ZONE 1 / 2 - ZONE 21 / 22 PROTECTION DEGREE IP65 IP66 IMQ 08 ATEX 008X IMQ 08 ATEX 026X EN 60079-0; EN 60079-15; EN 61241-0; 61241-1 EN 60070-0; EN 60079-7; EN 61241-0; EN 61241-1 CERTIFICATE REF. RULES OF COMPLIANCE Mechanical characteristics Body glass fibre reinforced polyester resin Diffuser U/V resistant polycarbonate - hinged to body Safety closing stainless steel hooks with safety device Gaskets EPDM 60 rubber suitable for high temperatures and resistant to enviroments conditions Internal reflector white stove enamelled sheet steel Cable entry complete with PVC cable gland Electrical characteristics Power supply dual channel electronic ballast 220/240V 50/60Hz (cos ρ ≥ 0,98) Lampholders bi-pin G13 cap Terminals suitable up to 6mm/sq cables On Request Accessories: • Pole mounting kit complete with stainless steel hardware • Ceiling mounting kit complete with stainless steel hardware • Pendant mounting kit complete with stainless steel hardware • Wall/Structure mounting kit complete with stainless steel hardware • Electronic ballast with voltage supply different than standard • Ex-de safety switch • AUTOTEST electronic system for emergency unit Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 49 EVSN Ex Lighting
  • 50. Ex Lighting EVSN Technical data EVSN CODE LAMP TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE ENTRY WITH EMERGENCY CABLE GLAND UNIT AUTONOMY DETAIL FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50Hz T6 T 85°C EVSN118EL T5 T100°C T4 T135°C 1 x 18W T6 T5 T100°C 1 x PG 13,5 - - A 1 x PG 13,5 - - A T 85°C EVSN136EL G13 1 x 36W G1 T4 T135°C EVSN158EL T5 T100°C T6 T 85°C EVSN218EL T5 T100°C T4 T135°C 1 x 58W 2 x 18W T6 T5 T100°C 1 x PG 13,5 2 x 36W - - - A G13 1 x PG 13,5 G13 1 x PG 13,5 - - A G13 1 x PG 13,5 - - A T 85°C EVSN236EL G13 - A T4 T135°C EVSN258EL T5 T100°C 2 x 58W EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50Hz T6 T 85°C EVSNE118EL T5 T100°C T4 T135°C 1 x 18W T6 T5 4,8V - 4Ah 3h B G13 1 x PG 13,5 4,8V - 4Ah 3h B G13 1 x PG 13,5 4,8V - 4Ah 3h B G13 T100°C 1 x PG 13,5 1 x PG 13,5 4,8V - 4Ah 3h B 1 x PG 13,5 4,8V - 4Ah 3h B G13 1 x PG 13,5 4,8V - 4Ah 3h B D [mm] WEIGHT [Kg] T 85°C EVSNE136EL G13 1 x 36W T4 T135°C EVSNE158EL T5 T100°C 1 x 58W T6 T 85°C EVSNE218EL T5 T100°C T4 T135°C T6 T 85°C EVSNE236EL T5 T100°C 2 x 18W 2 x 36W G13 T4 T135°C T5 EVSNE258EL 2 x 58W T100°C EVSN Technical features CODE A [mm] B [mm] C [mm] CABLE ENTRY DETAIL EVSN118EL 667 90 98 420 1,75 1 x PG 13,5 A EVSN136EL 1276 90 98 775 2,45 1 x PG 13,5 A EVSN158EL 1576 90 98 1070 3,10 1 x PG 13,5 A EVSN218EL 667 155 102 455 2,10 1 x PG 13,5 A EVSN236EL 1276 155 102 770 3,90 1 x PG 13,5 A EVSN258EL 1576 155 102 1055 5,20 1 x PG 13,5 A Reference details D C A A B Since 1961 50 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 51. Ex Lighting EVSN Technical features CODE B [mm] C [mm] 842 90 120 EVSNE136EL 1451 90 EVSNE158EL 1751 90 EVSNE218EL 842 EVSNE236EL EVSNE258EL D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL 420 2,75 1 x PG 13,5 B 120 775 3,45 1 x PG 13,5 B 120 1070 4,10 1 x PG 13,5 B 155 120 455 3,10 1 x PG 13,5 B 1451 155 120 770 4,90 1 x PG 13,5 B 1751 155 120 1055 6,20 1 x PG 13,5 B Reference details B C D A B EVSN Installation and mounting details Ceiling mounting Pendant mounting type 1 type 2 Wall/structure mounting type 3 0 10 type 4 Pole mounting Assemblig detail with pole (typical) 50 100 45° Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 51 EVSN A [mm] EVSNE118EL
  • 52. Ex Lighting EVSN Polar diagrams – photometric data EVS136 EVS158 EVS218 EVS236 EVS258 EVSN EVS118 EVSN On request accessories CODE DESCRIPTION INSTALLATION MATERIAL 20302.0122 POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20302.0123 POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20302.0125 POLE MOUNTING KIT (SIZE 1” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0165 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 STAINLESS STEEL 20303.0091 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 GALVANIZED STEEL 20303.0092 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 52 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 53. FLOODLIGHTS FOR DISCHARGE LAMPS Explosion Proof Electrical Equipment Installation: hazardous areas - Zone 2 (Gases) - Zone 22 (Dusts) Classification: Group II - Category 3G 3D SFDN FLOODLIGHT ATEX 94/9/EC II 3 G Ex nR II T3 II 3 D Ex tD A22 T200°C EXECUTION AMBIENT TEMPERATURE -20°C ÷ +60°C PROTECTION DEGREE IP66 CERTIFICATE REF. IMQ 08 ATEX 019 RULES OF COMPLIANCE EN 60079-0; EN 60079-15; EN 61241-0; 61241-1 Mechanical characteristics Body marine grade copper free aluminum Diffuser tempered front glass Support steel bracket with rotation-proof system Reflector anodized and polished 99,85 pure aluminum internal optic Painting thermosetting polyester powder resistant to atmospheric agents and corrosion grey RAL 9006 colour Screws stainless steel Gaskets pure silicon heat resistance Cable entry complete with cable gland Internal optic (S) symmetric optic - (A)asymmetric optic - (C) concentrating beam optic Electrical characteristics Power supply conventional ballast 230V - 50Hz (P.F. CORRECTED - cos ρ ≥ 0,95) Lampholders porcellain E40 / E27 size Internal wiring high-temperature resistant silicon rubber insulation cables Terminals suitable up to 4mm/sq cables On Request Accessories: • Control gear with voltage supply different than standard • Threaded cable entry different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 53 SFDN Ex Lighting
  • 54. Ex Lighting SFDN SFDN Technical data CODE LAMP TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY WITH CABLE GLAND DETAIL FLOODLIGHT FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V 50Hz SFDN#250HG-(1) 250 W T3 (Ta = -20°C / +60°C) T 200°C E-40 1 x PCE M20 A SFDN#400HG-(1) 400 W T3 (Ta = -20°C / +60°C) T 200°C E-40 1 x PCE M20 A FLOODLIGHT FOR METAL HALIDE LAMP - POWER SUPPLY 230V 50Hz SFDN#150MH-(1) 150 W T3 (Ta = -20°C / +60°C) T 200°C E-27 1 x PCE M20 A SFDN#250MH-(1) 250 W T3 (Ta = -20°C / +60°C) T 200°C E-40 1 x PCE M20 A SFDN#400MH-(1) 400 W T3 (Ta = -20°C / +60°C) T 200°C E-40 1 x PCE M20 A FLOODLIGHT FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V 50Hz SFDN#150HPNA-(1) 150 W T3 (Ta = -20°C / +60°C) T 200°C E-40 1 x PCE M20 A SFDN#250HPNA-(1) 250 W T3 (Ta = -20°C / +60°C) T 200°C E-40 1 x PCE M20 A SFDN#400HPNA-(1) 400 W T3 (Ta = -20°C / +60°C) T 200°C E-40 1 x PCE M20 A (1) INTERNAL OPTICAL BEAM: (S) SYMMETRIC BEAM - (A) ASYMMETRIC BEAM - (C) CONCENTRATING BEAM SAMPLE: SFDN#400MH-S = FLOODLIGHT 400W METAL HALIDE WITH SYMMETRIC OPTICAL BEAM SFDN Technical features CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL SFDN#250HG-(1) 544 461 430 180 8,80 1 x PCE M20 A SFDN#400HG-(1) 544 461 430 180 9,10 1 x PCE M20 A SFDN#150MH-(1) 544 461 430 180 9,50 1 x PCE M20 A SFDN#250MH-(1) 544 461 430 180 9,70 1 x PCE M20 A SFDN#400MH-(1) 544 461 430 180 11,00 1 x PCE M20 A SFDN#150HPNA-(1) 544 461 430 180 10,50 1 x PCE M20 A SFDN#250HPNA-(1) 544 461 430 180 11,10 1 x PCE M20 A SFDN#400HPNA-(1) 544 461 430 180 12,30 1 x PCE M20 A (1) INTERNAL OPTICAL BEAM: (S) SYMMETRIC BEAM - (A) ASYMMETRIC BEAM - (C) CONCENTRATING BEAM SAMPLE: SFDN#400MH-S = FLOODLIGHT 400W METAL HALIDE WITH SYMMETRIC OPTICAL BEAM Since 1961 54 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 55. Ex Lighting Reference details A D C www.feam-ex.com FLOODLIGHT TYPE SFDN 150W HPNA 250W HPNA 400W HPNA 230V 50Hz 240V 50HZ SM AS CT 150W MH 250W MH 400W MH 220V 60Hz 277 60Hz B 0.206m˛ IK10 Ex nR II T3 Ex tD A22 IP 66 T200°C A II 3 GD IMQ 09 ATEX 019 Tamb -20° C / +60° C TOGLIERE TENSIONE PRIMA DI APRIRE DO NOT OPEN WHILE ENERGIZED 0° 12 155 155 SFDN Polar diagrams – photometric data SFDN#250HPNA-S SFDN#250HPNA-A SFDN#250HPNA-C Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 55 SFDN SFDN Technical features
  • 56. Ex Lighting SFDN SFDN Polar diagrams – photometric data SFDN#400MH-S SFDN#400MH-A SFDN#400MH-C SFDN On request accessories CODE DESCRIPTION 20303.0099 PROTECTION GRID 20303.0100 MATERIAL POLE ADAPTER FOR DIA 40÷60MM Protection grid 20303.0099 ALUMINIUM PAINTED STEEL Pole adapter 20303.0100 REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 56 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 57. Explosion Proof Electrical Equipment Weatherproof Lighting EVSA Installation: Safe Area Insulation Class: I LIGHTING FIXTURE CEI / EN EXECUTION INDUSTRIAL WEATHERPROOF AMBIENT TEMPERATURE - PROTECTION DEGREE IP65 CERTIFICATE REF. - RULES OF COMPLIANCE EN 60598-1 + A1; EN 60598-2-1 Mechanical characteristics Body glass fibre reinforced polyester resin Diffuser U/V resistant polycarbonate - hinged to body Safety closing stainless steel hooks Gaskets EPDM 60 rubber suitable for high temperatures and resistant to enviroments conditions Internal reflector white stove enamelled sheet steel Cable entry complete with PVC cable gland Electrical characteristics Power supply dual channel electronic ballast 220/240V 50/60Hz (cos ρ ≥ 0,98) Lampholders bi-pin G13 cap Terminals suitable up to 6mm/sq cables On Request Accessories: • Pole mounting kit complete with stainless steel hardware • Ceiling mounting kit complete with stainless steel hardware • Pendant mounting kit complete with stainless steel hardware • Wall/Structure mounting kit complete with stainless steel hardware • Electronic ballast with voltage supply different than standard • Emergency Group Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 57 EVSA WEATHERPROOF FLUORESCENT LIGHTING FIXTURES
  • 58. Weatherproof Lighting EVSA Technical data EVSA CODE TEMPERATURE CLASS (GAS) LAMP TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE ENTRY WITH CABLE GLAND EMERGENCY UNIT AUTONOMY DETAIL FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50Hz EVSA118EL 1 x 18W - - G13 1 x PG 13,5 - - A EVSA136EL 1 x 36W - - G13 1 x PG 13,5 - - A EVSA158EL 1 x 58W - - G13 1 x PG 13,5 - - A EVSA218EL 2 x 18W - - G13 1 x PG 13,5 - - A EVSA236EL 2 x 36W - - G13 1 x PG 13,5 - - A EVSA258EL 2 x 58W - - G13 1 x PG 13,5 - - A EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50Hz EVSA118EL-E 1 x 18W - - G13 1 x PG 13,5 4,8V - 4Ah 3h A EVSA136EL-E 1 x 36W - - G13 1 x PG 13,5 4,8V - 4Ah 3h A EVSA158EL-E 1 x 58W - - G13 1 x PG 13,5 4,8V - 4Ah 3h A EVSA218EL-E 2 x 18W - - G13 1 x PG 13,5 4,8V - 4Ah 3h A EVSA236EL-E 2 x 36W - - G13 1 x PG 13,5 4,8V - 4Ah 3h A EVSA258EL-E 2 x 58W - - G13 1 x PG 13,5 4,8V - 4Ah 3h A EVSA Technical features CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL EVSA118EL 667 90 98 420 1,75 1 x PG 13,5 A EVSA136EL 1276 90 98 775 2,45 1 x PG 13,5 A EVSA158EL 1576 90 98 1070 3,10 1 x PG 13,5 A EVSA218EL 667 155 102 455 2,10 1 x PG 13,5 A EVSA236EL 1276 155 102 770 3,90 1 x PG 13,5 A EVSA258EL 1576 155 102 1055 5,20 1 x PG 13,5 A A [mm] B [mm] C [mm] D [mm] CODE EVSA118EL-E 667 90 98 WEIGHT [Kg] CABLE ENTRY DETAIL 420 1,75 1 x PG 13,5 A EVSA136EL-E 1276 90 98 775 2,45 1 x PG 13,5 A EVSA158EL-E 1576 90 98 1070 3,10 1 x PG 13,5 A EVSA218EL-E 667 155 102 455 2,10 1 x PG 13,5 A EVSA236EL-E 1276 155 102 770 3,90 1 x PG 13,5 A EVSA258EL-E 1576 155 102 1055 5,20 1 x PG 13,5 A Reference details A C D A B Since 1961 58 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 59. Weatherproof Lighting EVSA Installation and mounting details Ceiling mounting Pendant mounting type 2 Wall/structure mounting type 3 type 4 00 EVSA type 1 Pole mounting Assemblig detail with pole (typical) 1 50 100 45° EVSA Polar diagrams – photometric data EVS118 EVS136 EVS158 Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 59
  • 60. Weatherproof Lighting EVSA Polar diagrams – photometric data EVS236 EVSA EVS218 EVS258 EVSA On request accessories CODE DESCRIPTION INSTALLATION MATERIAL 20302.0122 POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20302.0123 POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20302.0125 POLE MOUNTING KIT (SIZE 1” DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL 20301.0165 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 STAINLESS STEEL 20303.0091 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 GALVANIZED STEEL 20303.0092 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 60 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 61. Explosion Proof Electrical Equipment Weatherproof Lighting SFDA Installation: Safe Area Insulation Class: I FLOODLIGHT CEI / EN EXECUTION INDUSTRIAL WEATHERPROOF AMBIENT TEMPERATURE - PROTECTION DEGREE IP66 CERTIFICATE REF. - RULES OF COMPLIANCE EN 60598-1 + A1; EN 60598-2-5 Mechanical characteristics Body marine grade copper free aluminum Diffuser tempered front glass Support steel bracket with rotation-proof system Reflector anodized and polished 99,85 pure aluminum internal optic Painting thermosetting polyester powder resistant to atmospheric agents and corrosion grey RAL 9006 colour Screws stainless steel Gaskets pure silicon heat resistance Cable entry complete with cable gland Internal optic (S) symmetric optic - (A)asymmetric optic - (C) concentrating beam optic Electrical characteristics Power supply conventional ballast 230V - 50Hz (P.F. CORRECTED - cos ρ ≥ 0,95) Lampholders porcellain E40 size Internal wiring high-temperature resistant silicon rubber insulation cables Terminals suitable up to 4mm/sq cables On Request Accessories: • ontrol gear with voltage supply different than standard C • hreaded cable entry different than standard T • eady for serial configuration through a second cable gland R • nternal optic definition under the symbol (S - A - C) to be added to the product code I Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 61 SFDA WEATHERPROOF FLOODLIGHTS FOR DISCHARGE LAMPS
  • 62. Weatherproof Lighting SFDA SFDA Technical data CODE LAMP TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE CABLE ENTRY WITH CABLE GLAND DETAIL FLOODLIGHT FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V 50Hz SFDA#250HG-(1) 250 W - - E-40 1 x PCE M20 A SFDA#400HG-(1) 400 W - - E-40 1 x PCE M20 A FLOODLIGHT FOR METAL HALIDE LAMP - POWER SUPPLY 230V 50Hz SFDA#150MH-(1) 150 W - - E-27 1 x PCE M20 A SFDA#250MH-(1) 250 W - - E-40 1 x PCE M20 A SFDA#400MH-(1) 400 W - - E-40 1 x PCE M20 A FLOODLIGHT FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V 50Hz SFDA#150HPNA-(1) 150 W - - E-40 1 x PCE M20 A SFDA#250HPNA-(1) 250 W - - E-40 1 x PCE M20 A SFDA#400HPNA-(1) 400 W - - E-40 1 x PCE M20 A (1) INTERNAL OPTICAL BEAM: (S) SYMMETRIC BEAM - (A) ASYMMETRIC BEAM - (C) CONCENTRATING BEAM SAMPLE: SFDA#400MH-S = FLOODLIGHT 400W METAL HALIDE WITH SYMMETRIC OPTICAL BEAM SFDA Technical features CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL SFDA#250HG-(1) 544 461 430 180 8,80 1 x PCE M20 A SFDA#400HG-(1) 544 461 430 180 9,10 1 x PCE M20 A SFDA#150MH-(1) 544 461 430 180 9,50 1 x PCE M20 A SFDA#250MH-(1) 544 461 430 180 9,70 1 x PCE M20 A SFDA#400MH-(1) 544 461 430 180 11,00 1 x PCE M20 A SFDA#150HPNA-(1) 544 461 430 180 10,50 1 x PCE M20 A SFDA#250HPNA-(1) 544 461 430 180 11,10 1 x PCE M20 A SFDA#400HPNA-(1) 544 461 430 180 12,30 1 x PCE M20 A (1) INTERNAL OPTICAL BEAM: (S) SYMMETRIC BEAM - (A) ASYMMETRIC BEAM - (C) CONCENTRATING BEAM S AMPLE: SFDA#400MH-S = FLOODLIGHT 400W METAL HALIDE WITH SYMMETRIC OPTICAL BEAM Since 1961 62 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 63. Weatherproof Lighting Reference details A D C www.feam-ex.com FLOODLIGHT TYPE SFDA SM AS CT 150W HPNA 250W HPNA 400W HPNA 150W MH 250W MH 400W MH 230V 50Hz 240V 50HZ 220V 60Hz 277 60Hz B 0.206m˛ A IK10 Tamb -20° C / +60° C TOGLIERE TENSIONE PRIMA DI APRIRE DO NOT OPEN WHILE ENERGIZED 0° 12 1 X PCE M20 155 155 SFDA Polar diagrams – photometric data SFDA#250HPNA-S SFDA#250HPNA-A SFDA#250HPNA-C Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 63 SFDA SFDA Technical features
  • 64. Weatherproof Lighting SFDA SFDA Polar diagrams – photometric data SFDA#400MH-S SFDA#400MH-A SFDA#400MH-C SFDA On request accessories CODE DESCRIPTION 20303.0099 PROTECTION GRID 20303.0100 MATERIAL POLE ADAPTER FOR DIA 40÷60MM Protection grid 20303.0099 ALUMINIUM PAINTED STEEL Pole adapter 20303.0100 REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 64 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 65. LIGHTING FIXTURES FOR DISCHARGE LAMPS Explosion Proof Electrical Equipment EWN Installation: hazardous areas - Zone 2 (Gases) - Zone 22 (Dusts) Classification: Group II - Category 3G 3D LIGHTING FIXTURE ATEX 94/9/EC II 3 G Ex nR II T3 II 3 D Ex tD A22 T200°C EXECUTION INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 PROTECTION DEGREE IP66 CERTIFICATE REF. - RULES OF COMPLIANCE EN 60079-0; EN 60079-15; EN 61241-0; EN 61241-1 Mechanical characteristics Body marine grade copper free aluminium (control gear & lamp body) globe high-temperature resistant borosylicate glass painting external epoxy powders grey ral-9006 colour screws external stainless steel gaskets silicon rubber Electrical characteristics Power supply conventional ballast 230v - 50hz (p.f.corrected - cos ρ ≥ 0,95) lampholders porcelain e27/e40 size internal wiring high-temperature resistant silicon rubber insulation cables terminals suitable up to 4mm/sq cables On Request Accessories: • eiling mounting kit complete with stainless steel hardware C • endant mounting kit complete with stainless steel hardware P • ole mounting 25° kit 1 1/2” dia. complete with stainless steel hardware P • all/Structure mounting kit complete with stainless steel hardware W • alvanized steel wire protection guard G • tainless steel wire protection guard S • White stove enamelled aluminium reflectors • White stove enamelled aluminium reflectors inclined 30° • Stainless steel AISI 316L reflectors • External painting colour on request • Control gear with voltage supply different than standard • Threaded cable entry different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 65 EWN Ex Lighting
  • 66. Ex Lighting EWN Technical data EWN CODE LAMP TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE DETAIL LIGHTING FIXTURE FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V 50Hz EWN2-80HG 80 W T3 T 200°C E-27 A EWN2-125HG 125 W T3 T 200°C E-27 A EWN3-250HG 250W T3 T 200°C E-40 A EWN5-400HG 400 W T3 T 200°C E-40 A LIGHTING FIXTURE FOR METAL HALIDE LAMP - POWER SUPPLY 230V 50Hz EWN2-70MH 70 W T3 T 200°C E-27 A EWN2-100MH 100 W T3 T 200°C E-27 A EWN2-150MH 150 W T3 T 200°C E-27 A EWN3-175MH 175 W T3 T 200°C E-40 A EWN3-250MH 250 W T3 T 200°C E-40 A EWN5-400MH 400 W T3 T 200°C E-40 A LIGHTING FIXTURE FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V 50Hz EWN2-70HPNA 70 W T3 T 200°C E-27 A EWN3-100HPNA 100 W T3 T 200°C E-27 A EWN3-150HPNA 150 W T3 T 200°C E-40 A EWN3-250HPNA 250 W T3 T 200°C E-40 A EWN5-400HPNA 400 W T3 T 200°C E-40 A EWN Technical features CODE A [mm] B [mm] C [mm] Ø D [mm] Ø E [mm] WEIGHT [Kg] DETAIL EWN2 280 430 415 145 280 8,50 A EWN3 280 510 480 190 402 9,50 A EWN5 280 570 545 255 515 10,00 A Reference details A C B ØA ØD ØE Since 1961 66 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 67. Ex Lighting EWN Installation and mounting details Pendant mounting type 1 3/4” type 2 1” Wall/structure mounting type 3 3/4” Pole mounting 25° 3/4” Universal mounting inst. with adjustable bracket type 5 45° 90 ° type 4 25° Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 67 EWN Ceiling mounting
  • 68. Ex Lighting EWN Polar diagrams – photometric data EWN400HPS-D EWN400MH-D EWN EWN250HG-D EWN On request accessories CODE DESCRIPTION INSTALLATION MATERIAL 20302.0070 EVAC 100 / 101 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM. 20302.0072 EVAC 300 / 301 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM. 20302.0073 EVAC 500 / 501 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM. 20302.0025 EVAC 100 / 101 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL AISI 316L 20302.0027 EVAC 300 / 301 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL AISI 316L 20302.0028 EVAC 500 / 501 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL AISI 316L 20302.0133 EVAC 100 / 101 SIZE STAINLESS STEEL REFLECTOR INCLINED 30° WHITE STOVE ENAMELLED ALUM. 20302.0031 EVAC 300 / 301 SIZE STAINLESS STEEL REFLECTOR INCLINED 30° WHITE STOVE ENAMELLED ALUM. EVAC 500 / 501 SIZE STAINLESS STEEL REFLECTOR INCLINED 30° WHITE STOVE ENAMELLED ALUM. 20302.0074 EVAC 100 / 101 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0076 EVAC 300 / 301 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0077 EVAC 500 / 501 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0037 EVAC 100 / 101 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL AISI 316L 20302.0039 EVAC 300 / 301 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL AISI 316L 20302.0040 EVAC 500 / 501 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL AISI 316L 20303.0108 2” DIA.SIZE POLE MONTING KIT C/W HARDWARE TYPE 4 ALUMININIUM 20303.0107 1-1/2” DIA.SIZE POLE MONTING KIT C/W HARDWARE TYPE 4 ALUMININIUM 20303.0106 1” DIA.SIZE POLE MONTING KIT C/W HARDWARE TYPE 4 ALUMININIUM 20303.0104 WALL MOUNTING KIT C/W HARDWARE TYPE 3 ALUMININIUM 20303.0103 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 ALUMININIUM 20303.0102 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 ALUMININIUM 20303.0105 UNIVERSAL MOUNTING INST. WITH ADJUSTABLE BRACKET C/W HARDWARE tYPE 5 STAINLESS STEEL AISI 316L REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 68 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 69. Explosion Proof Electrical Equipment Weatherproof Lighting EW Installation: Safe Area Insulation Class: I LIGHTING FIXTURE CEI / EN EXECUTION INDUSTRIAL WEATHERPROOF AMBIENT TEMPERATURE - PROTECTION DEGREE IP66 CERTIFICATE REF. - RULES OF COMPLIANCE EN 60598-1 + A1; EN 60598-2-1 Mechanical characteristics Body marine grade copper free aluminium (control gear & lamp body) globe high-temperature resistant borosylicate glass painting external epoxy powders grey ral-9006 colour screws external stainless steel gaskets silicon rubber Electrical characteristics Power supply conventional ballast 230v - 50hz (p.f.corrected - cos ρ ≥ 0,95) lampholders porcelain e27/e40 size internal wiring high-temperature resistant silicon rubber insulation cables terminals suitable up to 4mm/sq cables On Request Accessories: • eiling mounting kit complete with stainless steel hardware C • endant mounting kit complete with stainless steel hardware P • ole mounting 25° kit 1 1/2” dia. complete with stainless steel hardware P • all/Structure mounting kit complete with stainless steel hardware W • alvanized steel wire protection guard G • tainless steel wire protection guard S • White stove enamelled aluminium reflectors • White stove enamelled aluminium reflectors inclined 30° • Stainless steel AISI 316L reflectors • External painting colour on request • Control gear with voltage supply different than standard • Threaded cable entry different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 69 EW WEATHERPROOF LIGHTING FIXTURES
  • 70. Weatherproof Lighting EW Technical data LAMP EW CODE TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE DETAIL LIGHTING FIXTURE FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V 50Hz EW2-80HG 80 W - - E-27 A EW2-125HG 125 W - - E-27 A EW3-250HG 250W - - E-27 A EW5-400HG 400 W - - E-40 A LIGHTING FIXTURE FOR METAL HALIDE LAMP - POWER SUPPLY 230V 50Hz EW2-70MH 70 W - - E-27 A EW2-100MH 100 W - - E-27 A EW2-150MH 150 W - - E-27 A EW3-175MH 175 W - - E-40 A EW3-250MH 250 W - - E-40 A EW5-400MH 400 W - - E-40 A LIGHTING FIXTURE FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V 50Hz EW2-70HPNA 70 W - - E-27 A EW3-150HPNA 150 W - - E-40 A EW3-250HPNA 250 W - - E-40 A EW5-400HPNA 400 W - - E-40 A EW Technical features CODE A [mm] B [mm] C [mm] Ø D [mm] Ø E [mm] WEIGHT [Kg] DETAIL EW2 280 430 415 145 280 8,50 A EW3 280 510 480 190 402 9,50 A EW5 280 570 545 255 515 10,00 A Reference details A C B ØA ØD ØE Since 1961 70 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 71. Weatherproof Lighting EW Installation and mounting details Pendant mounting type 1 3/4” type 2 1” Wall/structure mounting type 3 3/4” Pole mounting 25° 3/4” Universal mounting inst. with adjustable bracket type 5 45° 90 ° type 4 25° Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 71 EW Ceiling mounting
  • 72. Weatherproof Lighting EW Polar diagrams – photometric data EW400HPS-D EW400MH-D EW EW250HG-D EW On request accessories CODE DESCRIPTION INSTALLATION MATERIAL 20302.0070 EVAC 100 / 101 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM. 20302.0072 EVAC 300 / 301 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM. 20302.0073 EVAC 500 / 501 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM. 20302.0025 EVAC 100 / 101 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL AISI 316L 20302.0027 EVAC 300 / 301 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL AISI 316L 20302.0028 EVAC 500 / 501 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL AISI 316L 20302.0133 EVAC 100 / 101 SIZE STAINLESS STEEL REFLECTOR INCLINED 30° WHITE STOVE ENAMELLED ALUM. 20302.0031 EVAC 300 / 301 SIZE STAINLESS STEEL REFLECTOR INCLINED 30° WHITE STOVE ENAMELLED ALUM. EVAC 500 / 501 SIZE STAINLESS STEEL REFLECTOR INCLINED 30° WHITE STOVE ENAMELLED ALUM. 20302.0074 EVAC 100 / 101 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0076 EVAC 300 / 301 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0077 EVAC 500 / 501 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL 20302.0037 EVAC 100 / 101 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL AISI 316L 20302.0039 EVAC 300 / 301 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL AISI 316L 20302.0040 EVAC 500 / 501 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL AISI 316L 20303.0108 2” DIA.SIZE POLE MONTING KIT C/W HARDWARE TYPE 4 ALUMININIUM 20303.0107 1-1/2” DIA.SIZE POLE MONTING KIT C/W HARDWARE TYPE 4 ALUMININIUM 20303.0106 1” DIA.SIZE POLE MONTING KIT C/W HARDWARE TYPE 4 ALUMININIUM 20303.0104 WALL MOUNTING KIT C/W HARDWARE TYPE 3 ALUMININIUM 20303.0103 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 ALUMININIUM 20303.0102 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 ALUMININIUM 20303.0105 UNIVERSAL MOUNTING INST. WITH ADJUSTABLE BRACKET C/W HARDWARE tYPE 5 STAINLESS STEEL AISI 316L REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 72 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 73. STREET LIGHTING FIXTURES Explosion Proof Electrical Equipment M400 Installation: Safe Area Insulation Class: I LIGHTING FIXTURE CEI/IEC EXECUTION INDUSTRial WEATHERPROOF AMBIENT TEMPERATURE IP66 (optic group) IP66 (control gear box) PROTECTION DEGREE CERTIFICATE REF. - RULES OF COMPLIANCE CEI / EN 60598-1 Mechanical characteristics Body die-cast aluminum Diffuser tempered glass 4mm thickness Anchorage cured poles Ø45-60mm (Ø40 with adapter) Reflector CUT-OFF optic - anodized and polished 99,85 pure aluminum Painting thermosetting polyester powder resistant to atmospheric agents and corrosion grey RAL 7038/7039 colour Screws stainless steel Gaskets silicon rubber gasket running oround the body Cable entry from pole Electrical characteristics Power supply conventional ballast 230V - 50Hz (P.F. CORRECTED - cos ρ ≥ 0,95) Lampholders porcellain E27 - E40 size Internal wiring high-temperature resistant silicon rubber insulation cables Terminals suitable up to 4mm/sq cables On Request Accessories: • Electronic ballast with voltage supply different than standard • Insulation class II • Angle/wall installation bracket • Pole adapter - dia. 40 mm Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 73 M400 Waterproof Lighting
  • 74. Waterproof Lighting M400 M400 Technical data CODE TEMPERATURE CLASS (GAS) LAMP TEMPERATURE CLASS (DUSTS) LAMPHOLDER SIZE DETAIL LIGHTING FIXTURE FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V 50Hz M400-125HG 125 W - - E-27 A M400-250HG 250 W - - E-40 A M400-400HG 400 W - - E-40 A LIGHTING FIXTURE FOR METAL HALIDE LAMP - POWER SUPPLY 230V 50Hz M400-70MH 70 W - - E-27 A M400-100MH 100 W - - E-27 A M400-150MH 150 W - - E-27 A M400-250MH 250 W - - E-40 A M400-400MH 400 W - - E-40 A LIGHTING FIXTURE FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V 50Hz M400-70HPNA 70 W - - E-27 A M400-100HPNA 100 W - - E-40 A M400-150HPNA 150 W - - E-40 A M400-250HPNA 250 W - - E-40 A M400-400HPNA 400 W - - E-40 A M400 Technical features CODE WEIGHT [Kg] A [mm] B [mm] C [mm] D [mm] DETAIL M400-125HG 719 224 387 228 10,20 A M400-250HG 719 224 387 228 11,50 A M400-400HG 719 224 387 228 12,90 A M400-70MH 719 224 387 228 10,40 A M400-100MH 719 224 387 228 10,40 A M400-150MH 719 224 387 228 11,70 A M400-250MH 719 224 387 228 11,70 A M400-400MH 719 224 387 228 13,00 A M400-70HPNA 719 224 387 228 10,50 A M400-100HPNA 719 224 387 228 10,50 A M400-150HPNA 719 224 387 228 11,70 A M400-250HPNA 719 224 387 228 13,00 A M400-400HPNA 719 224 387 228 14,30 A Since 1961 74 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 75. Waterproof Lighting M400 Technical features Reference details M400 A C B D A M400 Polar diagrams – photometric data M400-250HG M400-400HG M400-250HPS Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 75
  • 76. Waterproof Lighting M400 M400 Polar diagrams – photometric data M400-400Hps M400-250MH M400-400MH M400 On request accessories CODE DESCRIPTION 20303.0099 ANGLE/WALL INSTALLATION BRACKET 20303.0100 MATERIAL POLE ADAPTER - DIA. 40÷60MM Angle/wall installation bracket 20303.0099 ALUMINIUM PAINTED STEEL Pole adapter - dia. 40 mm 20303.0100 REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 76 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 77. CEILING LIGHTING FIXTURES Explosion Proof Electrical Equipment OFFICE Installation: Safe Area Insulation Class: I LIGHTING FIXTURE EXECUTION INDOOR LIGHTING AMBIENT TEMPERATURE - PROTECTION DEGREE IP20 / IP40 CERTIFICATE REF. - RULES OF COMPLIANCE EN 60598-1 + A1 Mechanical characteristics Body sheet steel Optical diff transparent methacrilate diffuser - white panted metal sheet frame Optical par “Darklight” - preanodised 99.85 aluminium double parabolic with 4u oxidation layer antiglare and antiridescent Painting epoxy-polyester powder coated in white Gasket anti-age cellular structure Electrical characteristics Power supply electronic ballast 220/240V 50/60Hz p.f. corrected (cos ρ ≥ 0,98) Lampholders bi-pin G13 cap Internal wiring high temperature resistant silicon rubber insulation cables Terminals suitable up to 4mm/sq cables On Request Accessories: • Electronic ballast with voltage supplì different than standard • Emergency unit with charger and battery pack Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 77 OFFICE Indoor Lighting
  • 78. Indoor Lighting LAMP TYPE CODE TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE ENTRY DETAIL FLUORESCENT LIGHTING FIXTURES WITH DARKLIGHT OPTICAL - POWER SUPPLY 230V-50Hz CABLE GLAND Ø20mm A - G13 CABLE GLAND Ø20mm A - - G13 G13 CABLE GLAND Ø20mm A G13 CABLE GLAND Ø20mm A G13 CABLE GLAND Ø20mm A G13 CABLE GLAND Ø20mm A OFFICE-PAR-136 1 x 36W - OFFICE-PAR-158 1 x 58W - OFFICE-PAR-218 2 x 18W - OFFICE-PAR-236 2 x 36W - - OFFICE-PAR-258 2 x 58W - - OFFICE-PAR-418 4 x 18W - - FLUORESCENT LIGHTING FIXTURES WITH METHACRILATE DIFFUSER - POWER SUPPLY 230V-50Hz OFFICE-DIFF-218 2 x 18W - OFFICE-DIFF-236 2 x 36W - OFFICE-DIFF-418 4 x 18W - - G13 CABLE GLAND Ø20mm A - G13 CABLE GLAND Ø20mm A - G13 CABLE GLAND Ø20mm A OFFICE Technical features CODE A [mm] B [mm] C [mm] FIXING [mm] WEIGHT [Kg] CABLE ENTRY DETAIL OFFICE-(1)-136 1225 180 90 1023 x 90 3,80 CABLE GLAND Ø20mm A OFFICE-(1)-158 1525 180 90 1323 x 90 4,90 CABLE GLAND Ø20mm A OFFICE-(1)-218 618 306 90 414 x 130 3,30 CABLE GLAND Ø20mm A OFFICE-(1)-236 1225 306 90 1023 x 130 6,20 CABLE GLAND Ø20mm A OFFICE-(1)-258 1525 306 90 1323 x 130 8,00 CABLE GLAND Ø20mm A OFFICE-(1)-418 618 610 90 414 x 496 5,70 CABLE GLAND Ø20mm A (1) OPTICAL / DIFFUSER: PAR = DARKLIGHT - DIFF= TRANSPARENT METHACRILATE Reference details A C OFFICE OFFICE Technical data A OFFICE-PAR-218 OFFICE-PAR-236 B OFFICE-PAR-418 REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 78 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 79. Explosion Proof Electrical Equipment Weatherproof Lighting SECURLUX Installation: Safe Area Insulation Class: I LIGHTING FIXTURE CEI / EN EXECUTION INDUSTRIAL WATERPROOF AMBIENT TEMPERATURE - PROTECTION DEGREE IP66 CERTIFICATE REF. - RULES OF COMPLIANCE EN 60598-1 + A1 Mechanical characteristics Body extruded aluminum, type UNI 9006T, 2,5mm thick; 15 ÷ 20 micron axidation thikness Diffuser transparent ribbed polycarbonate, 2,2mm thick Screws stainless steel Gaskets EPDM rubber suitable for high temperatures and resistant to enviroments conditions Reflector sheet steel polyurethane powder coated in white, ready for electrical components housing Cable Entry PG16 complete with poliamyde cable gland Locking top edges black self-extinguishing polycarbonate Electrical characteristics Power supply electronic ballast 220/240V 50/60Hz p.f. corrected (cos ρ ≥ 0,98) Lampholders bi-pin G13 cap Terminals suitable up to 4mm/sq cables On Request Accessories: • Pole mounting kit complete with stainless steel hardware • Pendant mounting kit complete with stainless steel hardware • Wall/structure mounting kit complete with stainless steel hardware • Electronic ballast with voltage supply different than standard • Steel protection cage Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 79 SECURLUX ANTI-VANDALIC LIGHTING FIXTURES FOR FLUORESCENT TUBE LAMPS
  • 80. SECURLUX Technical data LAMP TYPE CODE TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE ENTRY DETAIL FLUORESCENT LIGHTING FIXTURES FOR SINGLE, TWIN LAMPS - POWER SUPPLY 230V-50/60Hz SECURLUX-118 1 x 18W - - G13 1 x PG16 A SECURLUX-136 1 x 36W - - G13 1 x PG 16 A SECURLUX-158 1 x 58W - - G13 1 x PG 16 A SECURLUX-218 2 x 18W - - G13 1 x PG 16 A SECURLUX-236 2 x 36W - - G13 1 x PG 16 A SECURLUX-258 2 x 58W - - G13 1 x PG 16 A SECURLUX Technical features CODE A [mm] B [mm] C [mm] WEIGHT [Kg] CABLE ENTRY DETAIL SECURLUX-118 660 135 145 10,00 1 x PG16 A SECURLUX-136 1270 135 145 13,00 1 x PG16 A SECURLUX-158 1570 135 145 17,00 1 x PG16 A SECURLUX-218 660 135 145 10,50 1 x PG16 A SECURLUX-236 1270 135 145 13,50 1 x PG16 A SECURLUX-258 1570 135 145 17,50 1 x PG16 A Reference details A C 1xPG16 B A SECURLUX Installation and mounting details Pendant mounting Wall/structure mounting type 2 10 0 type 1 100 ° 45 50 SECURLUX Weatherproof Lighting Since 1961 80 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 81. SECURLUX Installation and mounting details Pole mounting Assemblig detail with pole (typical) type 3 SECURLUX Polar diagrams – photometric data SECURLUX 118 SECURLUX 218 SECURLUX 113 Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 81 SECURLUX Weatherproof Lighting
  • 82. SECURLUX Weatherproof Lighting SECURLUX Polar diagrams – photometric data SECURLUX 236 SECURLUX 158 SECURLUX 258 SECURLUX On request accessories INSTALLATION MATERIAL 20302.0122 CODE POLE MOUNTING KIT (SIZE 1 1/2” DIA.) C/W HARDWARE DESCRIPTION TYPE 3 GALVANIZED STEEL 20302.0123 POLE MOUNTING KIT (SIZE 2” DIA.) C/W HARDWARE TYPE 3 GALVANIZED STEEL 20302.0125 POLE MOUNTING KIT (SIZE 1” DIA.) C/W HARDWARE TYPE 3 GALVANIZED STEEL 20301.0165 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 1 STAINLESS STEEL 20303.0092 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 2 GALVANIZED STEEL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 82 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 83. Explosion Proof Electrical Equipment Waterproof Lighting KRONOS SAT Installation: safe area Insulation class: I INDUSTRIAL REFLECTORS CEI / EN EXECUTION WEATHERPROOF AMBIENT TEMPERATURE - PROTECTION DEGREE IP65 CERTIFICATE REF. - RULES OF COMPLIANCE EN 60598-1 + A1; EN 60598-2-5 Mechanical characteristics Housing die-casting aluminium complete with stainless steel safety chains Diffuser plane tempered glass resistant to shocks and thermal shocks, coupled with stainless steel clips and secured with a security chain Painting thermosetting polyester powder resistant to atmospheric agents and corrosion Reflector anodized and polished 99,85 pure aluminum Cable entry cable gland M20 IP68 tear proof Electrical characteristics Power supply conventional ballst 230V - 50Hz p.f. corrected (cos ρ ≥ 0,95) Lampholders ceramic E27 / E40 Internal wiring 1,5mm/sq silicon cables with glass sheat On Request Accessories: • Galvanized steel wire protection guard • Electronic device for aux halogen lamp • Control gear with voltage supply different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 83 KRONOS SAT INDUSTRIAL REFLECTORS FOR DISCHARGE LAMPS
  • 84. KRONOS SAT Technical data LAMP TYPE CODE TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE GLAND DETAIL INDUSTRIAL REFLECTORS FOR MERCURY VAPOUR LAMPS - POWER SUPPLY 230V-50Hz KRONOS-125MBF 125 W - - E-27 M20 A KRONOS-250MBF 250 W - - E-40 M20 A KRONOS-400MBF 400 W - - E-40 M20 A INDUSTRIAL REFLECTORS FOR METAL HALIDE LAMPS - POWER SUPPLY 230V-50Hz KRONOS-150JM 150 W - - E-27 M20 A KRONOS-250JM 250 W - - E-40 M20 A KRONOS-400JM 400 W - - E-40 M20 A INDUSTRIAL REFLECTORS FOR HIG PRESSURE SODIUM LAMPS - POWER SUPPLY 230V-50Hz KRONOS-150SAP 150 W - - E-40 M20 A KRONOS-250SAP 250 W - - E-40 M20 A KRONOS-400SAP 400 W - - E-41 M20 A KRONOS SAT Technical features Reference details A B ØC ØD WEIGHT CABLE GLAND DETAIL [mm] [mm] [mm] [mm] [Kg] CODE 535 265 550 295 4,62 M20 A KRONOS-250MBF 535 265 550 295 5,03 M20 A KRONOS-400MBF 535 265 550 295 6,35 M20 A KRONOS-150JM 535 265 550 295 5,22 M20 A KRONOS-250JM 535 265 550 295 5,17 M20 A KRONOS-400JM 535 265 550 295 6,50 M20 A KRONOS-150SAP 535 265 550 295 5,22 M20 A KRONOS-250SAP 535 265 550 295 6,57 M20 A KRONOS-400SAP 535 265 550 295 7,76 M20 A ØD KRONOS-400MBF KRONOS-250SAP B KRONOS-125MBF A A KRONOS SAT Waterproof Lighting ØC KRONOS-400JM KRONOS SAT On request accessories CODE DESCRIPTION 930000.480 PROTECTION GRID Ø480 CLA ELECTRONIC SWITCHING DEVICE FOR AUXILIARY LAMP MATERIAL GALVANIZED STEEL - REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 84 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 85. Explosion Proof Electrical Equipment Waterproof Lighting GENIUS Installation: safe area Insulation class: I LIGHTING FIXTURE CEI / EN EXECUTION INDUSTRIAL WATERPROOF AMBIENT TEMPERATURE -40°C ÷ +70°C PROTECTION DEGREE IP65 CERTIFICATE REF. - RULES OF COMPLIANCE EN 60598-1 + A1; EN 60598-2-1 Mechanical characteristics Body & frame seamless AISI-3104 stainless steel one piece deep drawn Diffuser transparent tempered flat glass 5mm thick. with silicon rubber gasket Screws stainless steel Gaskets EPDM rubber suitable for high temperatures and resistant to enviroments conditions Reflector internal in die-fold steel, epoxy powders white coloured coated equiped with security strings Cable entry PG 13,5 complete with poliamyde cable gland Closing hooks stainless steel with screw-held spring lock latches and anti-vandal device Electrical characteristics Power supply electronic ballast 230V - 50/60Hz p.f. corrected (cos ρ ≥ 0,98) Lampholders bi-pin G13 cap Terminals suitable up to 4mm/sq cables On Request Accessories: • Pole mounting kit complete with stainless steel hardware • Pendant mounting kit complete with stainless steel hardware • Wall/structure mounting kit complete with stainless steel hardware • Emergency unit complete with inverter charger and Ni-Cd 4,8V 4A/h battery pack • Electronic ballast with voltage supply different than standard Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 85 GENIUS LIGHTING FIXTURES FOR FLUORESCENT TUBE LAMPS
  • 86. Waterproof Lighting CODE LAMP TYPE TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE ENTRY EMERG.UNIT AUTONOMY (ON REQUEST) (EMERG.UNIT) DETAIL FLUORESCENT LIGHTING FIXTURES FOR SINGLE, TWIN, AND THREE LAMPS - POWER SUPPLY 230V-50/60Hz GENIUS-118 1 x 18W - - G13 1 x PG 13.5 4,8V - 4A/h 3h A GENIUS-136 1 x 36W - - G13 1 x PG 13.5 4,8V - 4A/h 3h A GENIUS-158 1 x 58W - - G13 1 x PG 13.5 4,8V - 4A/h 3h A GENIUS-218 2 x 18W - - G13 1 x PG 13.5 4,8V - 4A/h 3h A GENIUS-236 2 x 36W - - G13 1 x PG 13.5 4,8V - 4A/h 3h A GENIUS-258 2 x 58W - - G13 1 x PG 13.5 4,8V - 4A/h 3h A GENIUS-318 3 x 18W - - G13 1 x PG 13.5 4,8V - 4A/h 3h A GENIUS-336 3 x 36W - - G13 1 x PG 13.5 4,8V - 4A/h 3h A GENIUS Technical features CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL GENIUS-118 700 220 90 480 12,50 1 x PG 13,5 A GENIUS-136 1310 220 90 1090 15,50 1 x PG 13,5 A GENIUS-158 1610 220 90 1390 18,50 1 x PG 13,5 A GENIUS-218 700 220 90 480 13,00 1 x PG 13,5 A GENIUS-236 1310 220 90 1090 16,00 1 x PG 13,5 A GENIUS-258 1610 220 90 1390 19,00 1 x PG 13,5 A GENIUS-318 700 220 90 1090 13,50 1 x PG 13,5 A GENIUS-336 1310 220 90 1390 16,50 1 x PG 13,5 A Reference details A D 1 x PG 13,5 C GENIUS GENIUS Technical data B A REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 86 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 87. EXIT EMERGENCY LIGHTING FIXTURE Explosion Proof Electrical Equipment ESO Installation: safe area Insulation class: I LIGHTING FIXTURE CEI / EN EXECUTION INDUSTRial WEATHERPROOF AMBIENT TEMPERATURE - PROTECTION DEGREE IP40 CERTIFICATE REF. - RULES OF COMPLIANCE EN 60598-1 + A1; EN 60598-2-1 Mechanical characteristics Body techno polymer thermo resistant and anti shok, flame resistant chemical and atmospheric agents Diffuser transparent ribbed polycarbonate, 2,2mm thick Electrical characteristics Power supply electronic ballast 230V - 50Hz p.f. corrected (cos ρ ≥ 0,98) Lampholders bi-pin G5 cap Battery pack Ni-Cd high temperature 1,5Ah - time to recharge 12h - autonomy 1h / 3h Optical signal luminors indicator for power presence and correct recharging Self-diagnosis circuit (ATD) execute automatic functioning tests; a red flashing light indicate eventual wrong operations On Request Accessories: • Adhesive labels (with various symbols) according to European standards 92/58 Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 87 ESO Waterproof Lighting
  • 88. Waterproof Lighting LAMP TYPE CODE TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) LAMPHOLDER CABLE ENTRY EMERG.UNIT (ONREQUEST) AUTONOMY (EMERG.UNIT) DETAIL FLUORESCENT LIGHTING FIXTURES FOR SINGLE LAMP - POWER SUPPLY 230V-50/60Hz ESO 8-NA 1 x 8W - - G5 Ø20mm 2.4 V - 1.5Ah 1h A ESO 8-NA/3 1 x 8W - - G5 ESO 8-NS 1 x 8W - - G5 Ø20mm 6 V - 1.5Ah 3h A Ø20mm 2.4 V - 1.5Ah 1h A ESO 8-NS/3 1 x 8W - - G5 Ø20mm 6 V - 1.5Ah 3h A FLUORESCENT LIGHTING FIXTURES FOR SINGLE LAMP - POWER SUPPLY 230V-50/60Hz - SELF DIAGNOSTIC VERSION ESO 8-NA ATD 1 x 8W - - G5 Ø20mm 3.6 V - 1.5Ah 1h A ESO 8-NA/3 ATD 1 x 8W - - G5 Ø20mm 3.6 V - 4Ah 3h A ESO 8-NS ATD 1 x 8W - - G5 Ø20mm 3.6 V - 1.5Ah 1h A ESO 8-NS/3 ATD 1 x 8W - - G5 Ø20mm 3.6 V - 4Ah 3h A REMAKS: Always ON - Maintained “NA”: lighting fixtures light-on and working in emergency also Emergency only - Maintained “NS”: lighting fixtures light-off and working in emergency only ESO Technical features CODE A [mm] B [mm] C [mm] WEIGHT [Kg] CABLE ENTRY DETAIL ESO 8-NA 365 50 180 3,00 Ø20mm A ESO 8-NA/3 365 50 180 3,20 Ø20mm A ESO 8-NS 365 50 180 3,00 Ø20mm A ESO 8-NS/3 365 50 180 3,20 Ø20mm A ESO 8-NA ATD 365 50 180 3,20 Ø20mm A ESO 8-NA/3 ATD 365 50 180 3,50 Ø20mm A ESO 8-NS ATD 365 50 180 3,20 Ø20mm A ESO 8-NS/3 ATD 365 50 180 3,50 Ø20mm A Reference details A A B C ESO ESO Technical data REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 88 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 89. Explosion Proof Electrical Equipment Installation: hazardous areas - Zone 1/2 (Gases) - Zone 21/22 (Dusts) - Safe Area Ex Lighting towers LIGHTING MASTS WITH MOBILE CROWN FOR EXPLOSION PROOF FLOODLIGHS EEx d IIB T3 IP65 The utility of the high masts with mobile crown in lighting large areas, is universally recognised. It , in fact, represents the best answer either from the lighting environmental, maintenance point of view. Lighting high masts undertakes an irreplaceable part in designing modern lighting plant of large areas, having the approval of engineers who consider more and more difficult to find personnel for carrying out maintenance, disposed to climb to a certain height. Furthermore, the possibility of lighting large areas (interchanges, parking areas etc....) with few lighting sources of considerable height, without particular maintenance costs, makes FEAM high masts with mobile crown particularly profitable in the economy of the whole plant.. Our actual range, designed in standard elements suitable to guarantee maximum safety levels, with explosion proof floodlights for zone 1 and zone 2. MOVEMENT DETAIL motor cruck LIGHTING STUDY ON REQUEST Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 89 TORRI e PALI HIGH MAST TOWERS & LIGHTING POLES FOR HAZARDOUS AREA
  • 90. TORRI e PALI Ex Lighting Lighting poles Installation: hazardous areas - Zone 2 (Gases) - Zone 22 (Dusts) - Safe Area POLES LIGHTING COLUMNS FOR EXPLOSION PROOF CONNECTION BOX, LIGHTING FIXTURES AND FLOODLIGHTS Designed and manufactured according to national and European standard, FEAM lighting columns, are manufactured in 3 different types: • Conical columns with circular section • Stepped columns from welded tubes • Columns with octagonal and polygonal section Normally provided with standard works for the electric wiring according to the standard, they may be personalised with particular works upon request. Furthermore a complete range of accessories such as brackets, cross arms, make them suitable to the most different needs. All columns are protected against corrosion by means of hot galvanisation. REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 90 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 91. FASTENING ACCESSORIES, LIGHTING POLES Ex Lighting ACCESSORIES Installation: hazardous areas - Zone 1 / 2 (Gases) Zone 21 /22 (Dusts) - Safe Area U-Bolts Clamp Poles POLES Technical features A [mm] B [mm] ØC [mm] ØD R MATERIAL DETAIL PAL041 CODE 1900 1650 1-1/2” - 500 GALVANIZED STEEL A PAL042 500 1650 1-1/2” - 500 GALVANIZED STEEL A PAL855 2700 1650 2-1/2” 1-1/2” 500 GALVANIZED STEEL D PAS043 700 - 1” - 250 GALVANIZED STEEL B PAS856 3000 500 2-1/2” 1” 250 GALVANIZED STEEL C PAS857 2000 700 1-1/2” 1” 250 GALVANIZED STEEL C Other poles are supplied according to customer’s request Materials: stainless steel on request Reference details B C ØD ØD ØD D ØD R R ØC ØC ØC FIGURA A FIGURA FIGURA A FIGURA A A R R R ØC ØC ØC ØC A A A A A A A ØC R R R R A R 30° 30° 45° 45°° 45 45° ØD ØD R R R ØD R 30° A B B B 30° 30° 30° ØD ØDØD A A B B B R ØD A ØD ØD ØD B B ØD B A ØC ØC ØC ØC FIGURA B FIGURA FIGURA B FIGURA B B ØC ØC ØC ØC FIGURA C FIGURA FIGURA C FIGURA C C FIGURA D FIGURA FIGURA D FIGURA D D Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 91 ACCESSORI Explosion Proof Electrical Equipment
  • 92. CLAMP Technical features Reference details CODE Ø CONDUIT R MATERAL DETAIL GF1 1/2” 10 GALVANIZED STEEL GF2 3/4” 12 GALVANIZED STEEL E GF3 1” 15 GALVANIZED STEEL E GF4 1-1/4” 20 GALVANIZED STEEL E GF5 1-1/2” 22,5 GALVANIZED STEEL E GF6 2” 27,5 GALVANIZED STEEL E GF7 2-1/2” 35 ALUMINUM E GF8 3” 45 ALUMINUM E GF10 4” 60 ALUMINUM E E E R U-BOLTS Technical features Reference details CODE Ø CONDUIT R MATERAL DETAIL GH1 1/2” 10 GALVANIZED STEEL GH2 3/4” 12 GALVANIZED STEEL F GH3 1” 15 GALVANIZED STEEL F GH4 1-1/4” 20 GALVANIZED STEEL F GH5 1-1/2” 22,5 GALVANIZED STEEL F GH6 2” 27,5 GALVANIZED STEEL F GH7 2-1/2” 35 GALVANIZED STEEL F GH8 3” 45 GALVANIZED STEEL F GH10 4” 60 GALVANIZED STEEL F F F R ACCESSORI Ex Lighting With nuts and washer Materials: stainless steel on request REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 92 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY
  • 93. Installation: hazardous areas - Zone 1 / 2 (Gases) Zone 21 / 22 (Dusts) - Safe Area Explosion Proof Electrical Equipment Ex Lighting LIGHTING CALCULATION Lighting layout software for internal and external areas available by our office lighting calculation service for lighting installation to right and best position of luminaires in your project. Our technical staff offers its services in planning lighting installation, with photometric graphs and lighting data outputs in full according to Customer requirements. A well-organized software system is available to calculate the luminance level and the lighting distribution. This system will help you to plan the right and best position of FEAM luminaries in your project. It is enough you to inform us about the required illumination level: FEAM will present you the lighting project quickly. Using a proper software , our technical staff is able to insert FEAM lighting fixtures into a project and produce a virtual image of the area, which shows the real illuminating effect. Lighting calculation of example Since 1961 YOUR PARTNER FOR SAFETY Feam Catalogue 01 - 93 CALCOLO ILLUMINOMETRICO LIGHTING CALCULATION FOR EXTERNAL AND INTERNAL AREAS
  • 94. CALCOLO ILLUMINOMETRICO Ex Lighting Lighting calculation examples REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Since 1961 94 - Feam Catalogue 01 YOUR PARTNER FOR SAFETY

×