• Share
  • Email
  • Embed
  • Like
  • Save
  • Private Content
Pppnt1
 

Pppnt1

on

  • 190 views

project design 1: title presentation1

project design 1: title presentation1

Statistics

Views

Total Views
190
Views on SlideShare
190
Embed Views
0

Actions

Likes
0
Downloads
0
Comments
0

0 Embeds 0

No embeds

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

    Pppnt1 Pppnt1 Presentation Transcript

    • Effectiveness of the Telemetric Flood Monitoring Device______________________________________________________________ Computer Engineering Department College of Engineering Education University of Mindanao
    • Statement of the Problem This study is to establish the besttelemetric design for a flood monitoring device. Specifically, to answer the followingquestions: Effectiveness of the Telemetric Flood Monitoring Device
    • Statement of the Problem1. What is the average values using the following parameters: a) Water level, and b) Response time of the system?2. What are the physical specifications of the designs? Effectiveness of the Telemetric Flood Monitoring Device
    • Statement of the Problem3. How much would cost to develop the designs?4. What is the significant difference between the reading in terms of: a) Water level, and b) Response time of the system? Effectiveness of the Telemetric Flood Monitoring Device
    • Conceptual Framework EFFECTIVENESSTYPES OF DESIGN a) Water Level 1) Floating Sensor Reading2) Ultrasonic Sensor b) Response Time Effectiveness of the Telemetric Flood Monitoring Device
    • Research Procedure1. Test Effectiveness in: a) Water Level Readings: i. Actual Reading (human) ii. Displayed Reading (LCD/ Indicator) iii. Transmitted Reading (Server) b) Response time : Critical Water Level  Two test per trial c) 30 trials Effectiveness of the Telemetric Flood Monitoring Device
    • Research Procedure2. After the tally of readings and time, a) The specific component used and b) The actual cost Effectiveness of the Telemetric Flood Monitoring Device
    • Effectiveness of the Telemetric Flood Monitoring Device______________________________________________________________ Harold A. Caparida Jhun Bryan V. Cenabre Raldey T. Lape January 17, 2013