1. Thermally Broken Facades
TClip System for Rear Ventilated Rain Screen Facades
page 1
- October 13, 2012
2. Engineered Assemblies’ Values
Celebrate Architecture
Better buildings matter for the world
Uniting the house of Design with the field of
Construction
Design
Products Installation
2
3. How we got here
Cladding
Installation
Façade
Design
Passion for
something
better
Committed
to
Architecture
Materials
Knowledge
Simple
Building
Principles
page 3 - October 13, 2012
5. Why TClip patent pending
• Thermally broken façade suitable for Rear Ventilated Rain Screen ( RVRS )
• Non combustible construction
• Adjustable for subwall misalignment
• Cladding joints not tied to stud locations – design freedom
• Easy construction, cost effective
– fewer rows of clips than others, no insulation stickpins, insulation installed
easily and completely, simple window, door and edge conditions
• No premium over double girt system
• Suitable for weather barrier (as required by European DIN Standard)
• Suits all structures; steel stud, block, concrete
• Black vertical girts – corrosion resistant and best aesthetic
• Traditional installation practices, no training needed
• 3 clear field insulation thicknesses
• Designed to European DIN Standards, with prescribed airflow
• Supports Engineered Assemblies materials
• Made in Canada
page 5 - October 13, 2012
7. Trends in Design
Better Design
Building Building
Aesthetic Performance
Building
Higher R Envelope RVRS
Values Engineers on interest
team
page 7 - October 13, 2012
9. TClip Performance Engineering Complete
• Meets the prescriptive requirements for non- residential steel
stud walls in ASHRAE 90.1-2007/2010 for all climate zones.
• Performance of the system is validated through Modeling and
the Finite Element Analysis (FEA)
• Designed for Mid- and High-Rise (Non-Combustible) building
envelopes
• Engineered to accommodate Façade panels generally 8-26mm
in thickness
• Engineered for wind loads up to 50psf
• Optimized vertical spacing – 900mm up to 1200mm apart
page 9 - October 13, 2012
20. What matters with
Thermally Broken Façade Solutions
System Design Cost Non Suited for Works w All
Freedom = effective combustible Ventilated Insulations
facade
Design freedom = clips free to be anywhere so
Architect can create with no limits from substructure
page 20 - October 13, 2012
21. John Kubassek
Blair Davies
Engineered Assemblies
info@engineeredassemblies.com
905 816 2218
Go to www.engineeredassemblies.com
- Full MH report
- Executive Summary
- Youtube video showing installation
page 21 - October 13, 2012