Technical Data Sheet
           Edition 08.2010
           SUPERCAP™
 TM
                             SUPERCAP™
                             Premium Self-Leveling Underlayment Technology
           Description       SUPERCAP is a pumpable and pourable, cement-based, premium self-leveling underlayment based on a proprietary
SUPERCAP
                             mineral binder system that is used to finish concrete and level uneven floor surfaces. Apply it over concrete, wood and
                             other types of sound, rigid flooring before installing wood, resilient, cork, sports, ceramic, stone, carpet or other
                             flooring systems. Floor covering adhesives that are suitable for concrete can be used on SUPERCAP.
           Where to Use      Location:           ▪ Interior
                             Substrates:         ▪ Concrete
                                                 ▪ Wood
                                                 ▪ Rigid subflooring including VAT, VCT and ceramic tile
                             Applications: ▪ New concrete
                                           ▪ Deteriorated and uneven surfaces – deflection
                                           ▪ Restoration
           Advantages        •    Eliminates the need for power troweling concrete.
                             •    Can be installed over newly poured concrete as soon as five days after placement.
                             •    Finished floor goods may be installed as soon as 1-3 days after application, subject to thickness, drying conditions
                                  and type of flooring materials.
                             •    Eligible for two (2) LEED® project points for regional materials.
                             •    Low pH formulation allows for quick installation of finished floor goods.
                             •    Water damage stable; will not deteriorate, warp, buckle, or change shape even when soaked or exposed to high
                                  moisture conditions.
                             •    Surface is walkable in 2-4 hours and may be open to wheel traffic within 48 hours.
                             •    Can be left open to normal trade’s traffic for up to 6 months prior to installation of floor coverings.
                             •    Inorganic formulation will not contribute to or harbor growth of mold or mildew.
                             •    Will not contribute to secondary emissions or irritating fumes upon setting or curing.
           Technical Data    Typical Pour Depth ................................................................... ¼" to 2" (consult Technical Services for greater depths)
                             Coverage (sq. ft. @ ¼" per 50 lb. bag)....................................... 22 – 24*
                             Packaging ................................................................................. 50 lb bag, 45 bags per pallet | 2,500 lb Supersack
                             Walkable .................................................................................. 2-4 hours
                             Finished Floor Installation ........................................................ 3 days @ ¼" | 7 days @ ½" | 15 days @1" (72°F/50% RH)
                             Tensile Bond Strength (ASTM C 1583) ...................................... 28d >300 psi
                             Flexural Strength (ASTM C 348) ................................................ 28d >700 psi
                             Compressive Strength (ASTM C 109M) ..................................... 1d: 1700 psi | 7d: 2,800 psi | 28d: 4,200 psi
                             Set Time (ASTM C191) .............................................................. Initial @ 60 min | Final @ 70 min
                             Flow (1¼" x 2" metal ring) ........................................................ 145 mm
                             Flow Retention ......................................................................... 148 mm @ 20 min | 148 mm @ 30 min
                             Wet Density.............................................................................. 131-133 lbs/ft³
                             Installed Dry Weight (per square foot @ ¼") ............................ 2.35-2.47 lbs/ft2
                             Shelf Life................................................................................... 6 mo from date of manufacture in unopened package
                             All test methods and procedures are described in “Testing Hydraulic Characteristics of SUPERCAP”; a document that is available upon request.
                             *Mix water demand may vary due to regional raw materials where SUPERCAP is manufactured and may cause slight variations in physical properties.

           How to Use        New Concrete Slabs: Bull float to FF of 12-15, adjust finished elevation by ⅝" for 2-course slab; curing compounds are
                             not recommended. New concrete should be allowed to cure for a minimum of 5 days prior to installation of SUPERCAP.
                             Concrete must be free from hydrostatic pressure.
                             Concrete Floors (general): Substrate must be well-bonded (ICRI Technical Guideline No. 03739) and completely clean;
                             free of oil, wax, grease, sealers, curing compounds, asphalt, paint, dirt, loose surface material and any contaminate that
                             will act as a bond-breaker. Surface bond strength of substrate should be minimum 100 psi (0.69 MPa). Weak concrete
                             surfaces must be cleaned down to solid sound concrete by mechanical means. Acid etching or chemical cleaning is not
                             acceptable. Expansion joints in the concrete substrate must be reflected through the applied layer SUPERCAP. Concrete
                             must be free from hydrostatic pressure. Fill deep areas and depressions with a SUPERCAP pre-fill or suitable cement-
                             based concrete repair product. Repair cracks with epoxy grout. Material will flow as water and will go anywhere water
                             will go (contact Product Technologies’ Technical Service Department for details).
                             Over Cutback and Adhesive Residue: Supercap can be installed over non-soluble adhesives residues such as Cutback.
                             Cutback adhesives may contain asbestos fibers whose inhalation resulting from sanding or grinding maybe harmful.
                             Thick accumulation, brittle, powdery residue or weak unbonded adhesive must be removed using the wet-scrape and
                             wet-sweep method as outlined in the Resilient Floor Covering Institute www.rfci.com booklet. Consult your local,
                             provincial and federal regulations before attempting to remove or dispose of hazardous material for further
                             instructions. Remaining residue needs to be translucent, clean and well bonded to the substrate readied for SUPERCAP
                             PRIMER. Installation over non-Cutback adhesives is possible provided the residue is solid, bonded to substrate and NOT
                             water soluble. Avoid applications where heat may soften the adhesive causing de-lamination.
                             Water Soluble Adhesive: Mechanically remove by shotblasting or other acceptable mechanical means leaving a
                             Concrete Surface Profile (ICRI CSP) 3-5. Other surface contaminates may also require mechanical removal.
Wood Surfaces: The substrate must be clean, solid and secure to provide a rigid base; any movement should be
                eliminated by re-nailing. Hardwood floors, ¾" tongue and groove, Type 1 Exterior plywood are acceptable wood
                substrates. Follow the instructions contained in SUPERCAP PRIMER Technical Data Sheet. Install 2.5 lb galvanized lath




                                                                                                                                                                                                     TM TM
                sheets overlapping by 1" and using an 8" stapling pattern. Encapsulate the lath with a minimum of ¾" SUPERCAP.Non-
                Porous Substrates: Terrazzo, ceramic and quarry tile, burnished concrete, and epoxy coatings must be solid, well
                bonded, clean and free of any bond breaking contaminates such as glazes, wax, oil, sealers etc. Surfaces must be
                mechanically abraded until a "profile" is obtained. All debris, dust and loose material must be vacuumed prior to
                installing SUPERCAP PRIMER. Follow instructions contained in "NON-SUCTION" portion of SUPERCAP PRIMER Data Sheet.
                Steel Decking: All metal sub-floors and substrates require written approval from the Technical Department of Product
                Technologies LLC, prior to installation.




                                                                                                                                                                                                  SS U P E R C A P
Mixing          Bulk Sacks – Mixed in the PTI Pump Truck, a proprietary computer controlled mobile blending unit that mixes SUPERCAP
                onsite at street level to exact manufacturer specifications; operated by a PTI licensee.
                Small Bags – Precondition SUPERCAP to 70°F ±5° (21°C ±3°). Add the entire bag to 4.0 - 4.5 quarts (3.8 - 4.25 L) of clean,
                cool water and mix with a high power drill (650 RPM). CAUTION: DO NOT OVER WATER OR OVER MIX. OVER WATERING




                                                                                                                                                                                                   UPERCAP
                WILL CAUSE BLEEDING OR SAND SEGREGATION. Mix thoroughly for approximately 1½-2 minutes to obtain a uniform to
                lump-free consistency; scrape container’s sides and remix to incorporate remaining powder.
Application &   All substrates must be sound, stable and solid. Always prime the prepared surface with SUPERCAP PRIMER; allow
Finish          complete drying before the application of SUPERCAP, but do not exceed a 24-hour period. Surface must be primed again
                if 24-hour period is exceeded. Substrate temperature should be a minimum 43°F (+6°C) during application and air
                temperature maintained between 50-85°F (10-30°C). Protect areas from direct sunlight. Do not use damp curing
                methods or curing and sealing compounds. If required to meet level tolerances, survey surface using PTI’s LEVELER and
                apply LEVEL PEGS. Adequate ventilation should be provided to ensure uniform drying. Pour blended material onto
                substrate at an average thickness ranging between ¼" to 2" (7-50 mm) for all surfaces except lightweight concrete where
                a minimum thickness of ⅝ " and wood substrates minimum thickness of ¾" must be maintained. Immediately following
                placement lightly smooth the surface breaking surface tension and smoothing pour lines, when not using elevation pins
                the use of a gauge rack will assist in controlling material depth. Do not expose SUPERCAP to rolling dynamic loads, such
                as forklifts or scissor lifts, for at least 72 hours after installation. Proper application is the responsibility of the user. Field
                visits by Product Technologies personnel are for the purpose of making technical recommendations only and not for
                supervising or providing quality control on the jobsite.
Clean Up        In case of spillage, scoop or vacuum into appropriate container, and dispose of in accordance with current, applicable
                local, provincial and federal regulations. Keep container tightly closed and in an upright position to prevent spillage and
                leakage. Mixed components: When small amounts of SUPERCAP are splattered onto a painted surface, door, window or
                other finished surfaces, it can be removed with a clean white cloth that has been damped with clean potable water, even
                when dry. If the material is dry, allow the splatter to dampen and gently wipe while rotating the cloth.
Limitations     • Do not install SUPERCAP over particleboard, chipboard, hardboard (Masonite), Lauan panels, asbestos, gypsum-based
                  patching materials, asphalt, coal tar, or lightweight insulating concrete or any other dimensionally unstable materials.
                • SUPERCAP is not recommended for steel-wheeled traffic, exterior applications, or as a finished floor.
Caution         SUPERCAP may irritate eyes and skin and contains silica sand. Avoid contact with eyes, prolonged contact with skin or
                inhalation. In case of contact, flush thoroughly with water, wear protective gloves, goggles and respirator when dusty
                conditions exist. In confined areas, use of a NIOSH/MSHA approved respirator is recommended. Consult MSDS for
                additional information.
First Aid       In case of skin contact, wash with soap and water. For eye contact, flush immediately with plenty of water for at least 15
                minutes. Contact a physician. For respiratory problems, transport victim to fresh air.
                VOC Content: 0 grams/Liter or 0 pounds/gallon less water and exempt solvents.
                For more information, consult Production Technology’s Material Safety Data Sheet.
                KEEP OUT OF REACH OF CHILDREN
                For professional use only. Not for sale to or use by the general public.

                LIMITED WARRANTY NOTICE Every reasonable effort is made to apply Product Technologies’ exacting standards both in the manufacture of our products and in the
                information which we issue concerning these products and their use. We warrant our products to be of good quality and will replace or, at our election, refund the
                purchase price of any products proved defective. Satisfactory results depend not only upon quality products, but also upon many factors beyond our control. Therefore,
                except for such replacement or refund, PRODUCT TECHNOLOGIES LLC MAKES NO WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF FITNESS
                FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, RESPECTING ITS PRODUCTS, and PRODUCT TECHNOLOGIES shall have no other liability with respect thereto. Any
                claim regarding product defect must be received in writing within fifteen (15) day from the date of installation. No claim will be considered without such written notice or
                after the specified time interval. User shall determine the suitability of the products for the intended use and assume all risks and liability in connection therewith. Any
                authorized change in the printed recommendations concerning the use of our products must bear the signature of the Product Technologies’ Technical Director.
                This information and all further technical advice are based on Product Technologies’ present knowledge and experience. However, Product Technologies assumes no
                liability for providing such information and advice including the extent to which such information and advice may relate to existing third party intellectual property rights,
                especially patent rights. In particular, Product Technologies disclaims all CONDITIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, and INCLUDING THE IMPLIED
                WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. Product Technologies SHALL NOT BE RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR
                INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. Product Technologies reserves the right to make any changes according to technological progress or
                further developments. It is the customer’s responsibility and obligation to carefully inspect and test any incoming goods. Performance of the product(s) described herein
                should be verified by testing and carried out only by qualified experts. It is the sole responsibility of the customer to carry out and arrange for any such testing. Reference
                to trade names used by other companies is neither a recommendation, nor an endorsement of any product and does not imply that similar products could not be used.



                PRODUCT TECHNOLOGIES LLC                                                                Customer Service:                    1.866.704.2247
                620 CR 4841                                                                                                                  info@supercap.us.com
                Haslet, TX 76052                                                                        Technical Service:                   1.770.856.7030
                www.supercap.us.com                                                                                                          techsupport@supercap.us.com
                ©Product Technologies LLC 2010
                SUPERCAP™ is a registered trademark of Product Technologies LLC

More Related Content

What's hot (20)

Noble Drilling Case Study
Noble Drilling Case StudyNoble Drilling Case Study
Noble Drilling Case Study
 
Ruredil PBO Data Sheet
Ruredil PBO Data SheetRuredil PBO Data Sheet
Ruredil PBO Data Sheet
 
Tred Safe Product Brochure
Tred Safe Product BrochureTred Safe Product Brochure
Tred Safe Product Brochure
 
How To Avoid Screed Failure
How To Avoid Screed FailureHow To Avoid Screed Failure
How To Avoid Screed Failure
 
EC-1
EC-1EC-1
EC-1
 
Novafast SE Asia - Products
Novafast SE Asia - ProductsNovafast SE Asia - Products
Novafast SE Asia - Products
 
Fairflo 111
Fairflo 111Fairflo 111
Fairflo 111
 
Chemicals used in construction general studies
Chemicals used in construction general studies Chemicals used in construction general studies
Chemicals used in construction general studies
 
Sealing Compounds for Power Stations in India
Sealing Compounds for Power Stations in IndiaSealing Compounds for Power Stations in India
Sealing Compounds for Power Stations in India
 
Tds dampfix eg
Tds dampfix egTds dampfix eg
Tds dampfix eg
 
Shatin treatment works
Shatin treatment worksShatin treatment works
Shatin treatment works
 
Pressure Drill SF
Pressure Drill SFPressure Drill SF
Pressure Drill SF
 
Sikafloor 20 n-purcem
Sikafloor 20 n-purcemSikafloor 20 n-purcem
Sikafloor 20 n-purcem
 
Why sgp laminated glass cannot be replaced by dg41 laminated glass
Why sgp laminated glass cannot be replaced by dg41 laminated glassWhy sgp laminated glass cannot be replaced by dg41 laminated glass
Why sgp laminated glass cannot be replaced by dg41 laminated glass
 
Fairflo sca
Fairflo scaFairflo sca
Fairflo sca
 
Structural Product Guide of Treadwell Group
Structural Product Guide of Treadwell GroupStructural Product Guide of Treadwell Group
Structural Product Guide of Treadwell Group
 
Penetron PDS-v.B05
Penetron PDS-v.B05Penetron PDS-v.B05
Penetron PDS-v.B05
 
UBP
UBPUBP
UBP
 
Fibreglass (GRP) Linings & Coatings
Fibreglass (GRP) Linings & Coatings Fibreglass (GRP) Linings & Coatings
Fibreglass (GRP) Linings & Coatings
 
Flexsil - AMETEK FPP
Flexsil - AMETEK FPPFlexsil - AMETEK FPP
Flexsil - AMETEK FPP
 

Similar to Supercap tds english

Supercap data sheet..
Supercap data sheet..Supercap data sheet..
Supercap data sheet..ibndawood
 
Construction of metro station
Construction of metro stationConstruction of metro station
Construction of metro stationAmit Kumar Tiwari
 
TECHNICAL DATA SHEET | MOISTURE SEALING EPOXY PRIMER
TECHNICAL DATA SHEET | MOISTURE SEALING EPOXY PRIMERTECHNICAL DATA SHEET | MOISTURE SEALING EPOXY PRIMER
TECHNICAL DATA SHEET | MOISTURE SEALING EPOXY PRIMERPolytek Development Corp
 
PPT BPD Retail.pptx
PPT BPD Retail.pptxPPT BPD Retail.pptx
PPT BPD Retail.pptxanishmadaan1
 
Sikalastic 560 leaflet aus
Sikalastic 560 leaflet ausSikalastic 560 leaflet aus
Sikalastic 560 leaflet ausbadtothebones
 
(Pds) nitoproof rs_(green_label)
(Pds) nitoproof rs_(green_label)(Pds) nitoproof rs_(green_label)
(Pds) nitoproof rs_(green_label)HendraWahyu6
 
RIW Structureseal -Sodium Bentonite System - Typical Details
RIW Structureseal -Sodium Bentonite System - Typical DetailsRIW Structureseal -Sodium Bentonite System - Typical Details
RIW Structureseal -Sodium Bentonite System - Typical DetailsRIW Ltd
 
Car Park Protection - Mariseal 250 Flash
Car Park Protection - Mariseal 250 FlashCar Park Protection - Mariseal 250 Flash
Car Park Protection - Mariseal 250 FlashOrfeas Aggelou
 
detailed specification for cement concrete
detailed specification for cement concretedetailed specification for cement concrete
detailed specification for cement concretevivek gami
 
selfcompactingconcretescc-160316004923.pptx
selfcompactingconcretescc-160316004923.pptxselfcompactingconcretescc-160316004923.pptx
selfcompactingconcretescc-160316004923.pptxARUNKUMARC39
 
Building products presenation (2)
Building products presenation (2)Building products presenation (2)
Building products presenation (2)NICM
 
Korolozyon Kontrol Teknolojileri
Korolozyon Kontrol TeknolojileriKorolozyon Kontrol Teknolojileri
Korolozyon Kontrol Teknolojilerivizyonendustriyel1
 

Similar to Supercap tds english (18)

Supercap data sheet..
Supercap data sheet..Supercap data sheet..
Supercap data sheet..
 
Construction of metro station
Construction of metro stationConstruction of metro station
Construction of metro station
 
Flooring
FlooringFlooring
Flooring
 
TECHNICAL DATA SHEET | MOISTURE SEALING EPOXY PRIMER
TECHNICAL DATA SHEET | MOISTURE SEALING EPOXY PRIMERTECHNICAL DATA SHEET | MOISTURE SEALING EPOXY PRIMER
TECHNICAL DATA SHEET | MOISTURE SEALING EPOXY PRIMER
 
Sika latex
Sika latexSika latex
Sika latex
 
Floor Coating Epoxy Primer
Floor Coating Epoxy PrimerFloor Coating Epoxy Primer
Floor Coating Epoxy Primer
 
PPT BPD Retail.pptx
PPT BPD Retail.pptxPPT BPD Retail.pptx
PPT BPD Retail.pptx
 
Rubber Flooring Installation
Rubber Flooring InstallationRubber Flooring Installation
Rubber Flooring Installation
 
Sikalastic 560 leaflet aus
Sikalastic 560 leaflet ausSikalastic 560 leaflet aus
Sikalastic 560 leaflet aus
 
(Pds) nitoproof rs_(green_label)
(Pds) nitoproof rs_(green_label)(Pds) nitoproof rs_(green_label)
(Pds) nitoproof rs_(green_label)
 
Crackseal super
Crackseal superCrackseal super
Crackseal super
 
RIW Structureseal -Sodium Bentonite System - Typical Details
RIW Structureseal -Sodium Bentonite System - Typical DetailsRIW Structureseal -Sodium Bentonite System - Typical Details
RIW Structureseal -Sodium Bentonite System - Typical Details
 
Car Park Protection - Mariseal 250 Flash
Car Park Protection - Mariseal 250 FlashCar Park Protection - Mariseal 250 Flash
Car Park Protection - Mariseal 250 Flash
 
ISOMAT_Epoxy flooring systems
ISOMAT_Epoxy flooring systemsISOMAT_Epoxy flooring systems
ISOMAT_Epoxy flooring systems
 
detailed specification for cement concrete
detailed specification for cement concretedetailed specification for cement concrete
detailed specification for cement concrete
 
selfcompactingconcretescc-160316004923.pptx
selfcompactingconcretescc-160316004923.pptxselfcompactingconcretescc-160316004923.pptx
selfcompactingconcretescc-160316004923.pptx
 
Building products presenation (2)
Building products presenation (2)Building products presenation (2)
Building products presenation (2)
 
Korolozyon Kontrol Teknolojileri
Korolozyon Kontrol TeknolojileriKorolozyon Kontrol Teknolojileri
Korolozyon Kontrol Teknolojileri
 

Supercap tds english

  • 1. Technical Data Sheet Edition 08.2010 SUPERCAP™ TM SUPERCAP™ Premium Self-Leveling Underlayment Technology Description SUPERCAP is a pumpable and pourable, cement-based, premium self-leveling underlayment based on a proprietary SUPERCAP mineral binder system that is used to finish concrete and level uneven floor surfaces. Apply it over concrete, wood and other types of sound, rigid flooring before installing wood, resilient, cork, sports, ceramic, stone, carpet or other flooring systems. Floor covering adhesives that are suitable for concrete can be used on SUPERCAP. Where to Use Location: ▪ Interior Substrates: ▪ Concrete ▪ Wood ▪ Rigid subflooring including VAT, VCT and ceramic tile Applications: ▪ New concrete ▪ Deteriorated and uneven surfaces – deflection ▪ Restoration Advantages • Eliminates the need for power troweling concrete. • Can be installed over newly poured concrete as soon as five days after placement. • Finished floor goods may be installed as soon as 1-3 days after application, subject to thickness, drying conditions and type of flooring materials. • Eligible for two (2) LEED® project points for regional materials. • Low pH formulation allows for quick installation of finished floor goods. • Water damage stable; will not deteriorate, warp, buckle, or change shape even when soaked or exposed to high moisture conditions. • Surface is walkable in 2-4 hours and may be open to wheel traffic within 48 hours. • Can be left open to normal trade’s traffic for up to 6 months prior to installation of floor coverings. • Inorganic formulation will not contribute to or harbor growth of mold or mildew. • Will not contribute to secondary emissions or irritating fumes upon setting or curing. Technical Data Typical Pour Depth ................................................................... ¼" to 2" (consult Technical Services for greater depths) Coverage (sq. ft. @ ¼" per 50 lb. bag)....................................... 22 – 24* Packaging ................................................................................. 50 lb bag, 45 bags per pallet | 2,500 lb Supersack Walkable .................................................................................. 2-4 hours Finished Floor Installation ........................................................ 3 days @ ¼" | 7 days @ ½" | 15 days @1" (72°F/50% RH) Tensile Bond Strength (ASTM C 1583) ...................................... 28d >300 psi Flexural Strength (ASTM C 348) ................................................ 28d >700 psi Compressive Strength (ASTM C 109M) ..................................... 1d: 1700 psi | 7d: 2,800 psi | 28d: 4,200 psi Set Time (ASTM C191) .............................................................. Initial @ 60 min | Final @ 70 min Flow (1¼" x 2" metal ring) ........................................................ 145 mm Flow Retention ......................................................................... 148 mm @ 20 min | 148 mm @ 30 min Wet Density.............................................................................. 131-133 lbs/ft³ Installed Dry Weight (per square foot @ ¼") ............................ 2.35-2.47 lbs/ft2 Shelf Life................................................................................... 6 mo from date of manufacture in unopened package All test methods and procedures are described in “Testing Hydraulic Characteristics of SUPERCAP”; a document that is available upon request. *Mix water demand may vary due to regional raw materials where SUPERCAP is manufactured and may cause slight variations in physical properties. How to Use New Concrete Slabs: Bull float to FF of 12-15, adjust finished elevation by ⅝" for 2-course slab; curing compounds are not recommended. New concrete should be allowed to cure for a minimum of 5 days prior to installation of SUPERCAP. Concrete must be free from hydrostatic pressure. Concrete Floors (general): Substrate must be well-bonded (ICRI Technical Guideline No. 03739) and completely clean; free of oil, wax, grease, sealers, curing compounds, asphalt, paint, dirt, loose surface material and any contaminate that will act as a bond-breaker. Surface bond strength of substrate should be minimum 100 psi (0.69 MPa). Weak concrete surfaces must be cleaned down to solid sound concrete by mechanical means. Acid etching or chemical cleaning is not acceptable. Expansion joints in the concrete substrate must be reflected through the applied layer SUPERCAP. Concrete must be free from hydrostatic pressure. Fill deep areas and depressions with a SUPERCAP pre-fill or suitable cement- based concrete repair product. Repair cracks with epoxy grout. Material will flow as water and will go anywhere water will go (contact Product Technologies’ Technical Service Department for details). Over Cutback and Adhesive Residue: Supercap can be installed over non-soluble adhesives residues such as Cutback. Cutback adhesives may contain asbestos fibers whose inhalation resulting from sanding or grinding maybe harmful. Thick accumulation, brittle, powdery residue or weak unbonded adhesive must be removed using the wet-scrape and wet-sweep method as outlined in the Resilient Floor Covering Institute www.rfci.com booklet. Consult your local, provincial and federal regulations before attempting to remove or dispose of hazardous material for further instructions. Remaining residue needs to be translucent, clean and well bonded to the substrate readied for SUPERCAP PRIMER. Installation over non-Cutback adhesives is possible provided the residue is solid, bonded to substrate and NOT water soluble. Avoid applications where heat may soften the adhesive causing de-lamination. Water Soluble Adhesive: Mechanically remove by shotblasting or other acceptable mechanical means leaving a Concrete Surface Profile (ICRI CSP) 3-5. Other surface contaminates may also require mechanical removal.
  • 2. Wood Surfaces: The substrate must be clean, solid and secure to provide a rigid base; any movement should be eliminated by re-nailing. Hardwood floors, ¾" tongue and groove, Type 1 Exterior plywood are acceptable wood substrates. Follow the instructions contained in SUPERCAP PRIMER Technical Data Sheet. Install 2.5 lb galvanized lath TM TM sheets overlapping by 1" and using an 8" stapling pattern. Encapsulate the lath with a minimum of ¾" SUPERCAP.Non- Porous Substrates: Terrazzo, ceramic and quarry tile, burnished concrete, and epoxy coatings must be solid, well bonded, clean and free of any bond breaking contaminates such as glazes, wax, oil, sealers etc. Surfaces must be mechanically abraded until a "profile" is obtained. All debris, dust and loose material must be vacuumed prior to installing SUPERCAP PRIMER. Follow instructions contained in "NON-SUCTION" portion of SUPERCAP PRIMER Data Sheet. Steel Decking: All metal sub-floors and substrates require written approval from the Technical Department of Product Technologies LLC, prior to installation. SS U P E R C A P Mixing Bulk Sacks – Mixed in the PTI Pump Truck, a proprietary computer controlled mobile blending unit that mixes SUPERCAP onsite at street level to exact manufacturer specifications; operated by a PTI licensee. Small Bags – Precondition SUPERCAP to 70°F ±5° (21°C ±3°). Add the entire bag to 4.0 - 4.5 quarts (3.8 - 4.25 L) of clean, cool water and mix with a high power drill (650 RPM). CAUTION: DO NOT OVER WATER OR OVER MIX. OVER WATERING UPERCAP WILL CAUSE BLEEDING OR SAND SEGREGATION. Mix thoroughly for approximately 1½-2 minutes to obtain a uniform to lump-free consistency; scrape container’s sides and remix to incorporate remaining powder. Application & All substrates must be sound, stable and solid. Always prime the prepared surface with SUPERCAP PRIMER; allow Finish complete drying before the application of SUPERCAP, but do not exceed a 24-hour period. Surface must be primed again if 24-hour period is exceeded. Substrate temperature should be a minimum 43°F (+6°C) during application and air temperature maintained between 50-85°F (10-30°C). Protect areas from direct sunlight. Do not use damp curing methods or curing and sealing compounds. If required to meet level tolerances, survey surface using PTI’s LEVELER and apply LEVEL PEGS. Adequate ventilation should be provided to ensure uniform drying. Pour blended material onto substrate at an average thickness ranging between ¼" to 2" (7-50 mm) for all surfaces except lightweight concrete where a minimum thickness of ⅝ " and wood substrates minimum thickness of ¾" must be maintained. Immediately following placement lightly smooth the surface breaking surface tension and smoothing pour lines, when not using elevation pins the use of a gauge rack will assist in controlling material depth. Do not expose SUPERCAP to rolling dynamic loads, such as forklifts or scissor lifts, for at least 72 hours after installation. Proper application is the responsibility of the user. Field visits by Product Technologies personnel are for the purpose of making technical recommendations only and not for supervising or providing quality control on the jobsite. Clean Up In case of spillage, scoop or vacuum into appropriate container, and dispose of in accordance with current, applicable local, provincial and federal regulations. Keep container tightly closed and in an upright position to prevent spillage and leakage. Mixed components: When small amounts of SUPERCAP are splattered onto a painted surface, door, window or other finished surfaces, it can be removed with a clean white cloth that has been damped with clean potable water, even when dry. If the material is dry, allow the splatter to dampen and gently wipe while rotating the cloth. Limitations • Do not install SUPERCAP over particleboard, chipboard, hardboard (Masonite), Lauan panels, asbestos, gypsum-based patching materials, asphalt, coal tar, or lightweight insulating concrete or any other dimensionally unstable materials. • SUPERCAP is not recommended for steel-wheeled traffic, exterior applications, or as a finished floor. Caution SUPERCAP may irritate eyes and skin and contains silica sand. Avoid contact with eyes, prolonged contact with skin or inhalation. In case of contact, flush thoroughly with water, wear protective gloves, goggles and respirator when dusty conditions exist. In confined areas, use of a NIOSH/MSHA approved respirator is recommended. Consult MSDS for additional information. First Aid In case of skin contact, wash with soap and water. For eye contact, flush immediately with plenty of water for at least 15 minutes. Contact a physician. For respiratory problems, transport victim to fresh air. VOC Content: 0 grams/Liter or 0 pounds/gallon less water and exempt solvents. For more information, consult Production Technology’s Material Safety Data Sheet. KEEP OUT OF REACH OF CHILDREN For professional use only. Not for sale to or use by the general public. LIMITED WARRANTY NOTICE Every reasonable effort is made to apply Product Technologies’ exacting standards both in the manufacture of our products and in the information which we issue concerning these products and their use. We warrant our products to be of good quality and will replace or, at our election, refund the purchase price of any products proved defective. Satisfactory results depend not only upon quality products, but also upon many factors beyond our control. Therefore, except for such replacement or refund, PRODUCT TECHNOLOGIES LLC MAKES NO WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, RESPECTING ITS PRODUCTS, and PRODUCT TECHNOLOGIES shall have no other liability with respect thereto. Any claim regarding product defect must be received in writing within fifteen (15) day from the date of installation. No claim will be considered without such written notice or after the specified time interval. User shall determine the suitability of the products for the intended use and assume all risks and liability in connection therewith. Any authorized change in the printed recommendations concerning the use of our products must bear the signature of the Product Technologies’ Technical Director. This information and all further technical advice are based on Product Technologies’ present knowledge and experience. However, Product Technologies assumes no liability for providing such information and advice including the extent to which such information and advice may relate to existing third party intellectual property rights, especially patent rights. In particular, Product Technologies disclaims all CONDITIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, and INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. Product Technologies SHALL NOT BE RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. Product Technologies reserves the right to make any changes according to technological progress or further developments. It is the customer’s responsibility and obligation to carefully inspect and test any incoming goods. Performance of the product(s) described herein should be verified by testing and carried out only by qualified experts. It is the sole responsibility of the customer to carry out and arrange for any such testing. Reference to trade names used by other companies is neither a recommendation, nor an endorsement of any product and does not imply that similar products could not be used. PRODUCT TECHNOLOGIES LLC Customer Service: 1.866.704.2247 620 CR 4841 info@supercap.us.com Haslet, TX 76052 Technical Service: 1.770.856.7030 www.supercap.us.com techsupport@supercap.us.com ©Product Technologies LLC 2010 SUPERCAP™ is a registered trademark of Product Technologies LLC