SlideShare a Scribd company logo
1 of 6
Download to read offline
Bill Redirect
  Transfer serial barcode data as keystrokes into your Windows applications.
                                Into a specific field
                    (as if it was typed in using the keyboard)

                             Documentation: 17/12/2008




         Use this documentation with the product : Bill Redirect 5.0M and more


Software configuration and integration service
                     It's free, fast, and efficient !
             Submit your case to info@billproduction.com
                 and receive a customized answer !


                Our Internet site: http://www.billproduction.com/

                         Email: info@BillProduction.com
This documentation demonstrate how
Transfer serial barcode data as keystrokes into your Windows applications.
                            Into a specific field




 The following instructions apply to all Serial Port (RS-232) Barcode Readers
                                      and
           USB Barcode Reader that supports Com Port Emulation




                                  Step #1
           Download and install Bill Redirect software
                               5.0M or more
       http://www.billproduction.com/Bill_COMtoKB.ZIP


                                  Step #2




Disable all except the Serial Port and Keyboard Buffer section.
        Set to OFF Serial Port and Pressed key switch.
Step #3




                     Click on button: Configuration.
 Enter the Serial Port Number where your Barcode reader is connected.

Serial Port Configuration: Enter the configuration of your Barcode Reader.
Step #4




             To open the “Mouse Position” window




               Enter in the field Password: Mouse


                     Open your application




Move the mouse pointer on the field where the data should be sent.
    Click on this field and take in “Position on the Window”




                 For this example: 3165 and 990
Step #5




                                Click on button: Configuration




                                       Click on button: ADD




                                 Enter in this field: {ALL_RX}




                          Enter in this field:
APP[Shop Floor]{MOUSE_ACTION[3165,990,WINDOW,LEFT_CLICK]}RX_DATA
                           In this string 3165,990, is the field position noted before
                              In this string Shop Floor is your application name

        * You can enter just a part of the title, for example if the title is “Shop Floor Data Collection”
                         you can enter just a part of the title for example: Shop Floor
Step #6

              Click on button: OK



     Click on button: Save Configuration
                    TEST




    For more information, consult the product manual:
http://www.billproduction.com/Bill_Redirect_Manual.pdf

More Related Content

Viewers also liked

Your peripherals RS232 USB and Excel
Your peripherals RS232 USB and ExcelYour peripherals RS232 USB and Excel
Your peripherals RS232 USB and Exceltopomax
 
Microsoft access VBA communication with RS232 Peripherals
Microsoft access VBA  communication with RS232 PeripheralsMicrosoft access VBA  communication with RS232 Peripherals
Microsoft access VBA communication with RS232 Peripheralstopomax
 
Microsoft Excel and RS-232 peripherals protocol communication DDE
Microsoft Excel and RS-232 peripherals protocol communication DDEMicrosoft Excel and RS-232 peripherals protocol communication DDE
Microsoft Excel and RS-232 peripherals protocol communication DDEtopomax
 
Storm Keyboard / Keypad RS-232 Wedge keyboard solution
Storm Keyboard / Keypad RS-232  Wedge keyboard solutionStorm Keyboard / Keypad RS-232  Wedge keyboard solution
Storm Keyboard / Keypad RS-232 Wedge keyboard solutiontopomax
 
Bill redirect field
Bill redirect fieldBill redirect field
Bill redirect fieldtopomax
 
Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...
Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...
Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...topomax
 

Viewers also liked (6)

Your peripherals RS232 USB and Excel
Your peripherals RS232 USB and ExcelYour peripherals RS232 USB and Excel
Your peripherals RS232 USB and Excel
 
Microsoft access VBA communication with RS232 Peripherals
Microsoft access VBA  communication with RS232 PeripheralsMicrosoft access VBA  communication with RS232 Peripherals
Microsoft access VBA communication with RS232 Peripherals
 
Microsoft Excel and RS-232 peripherals protocol communication DDE
Microsoft Excel and RS-232 peripherals protocol communication DDEMicrosoft Excel and RS-232 peripherals protocol communication DDE
Microsoft Excel and RS-232 peripherals protocol communication DDE
 
Storm Keyboard / Keypad RS-232 Wedge keyboard solution
Storm Keyboard / Keypad RS-232  Wedge keyboard solutionStorm Keyboard / Keypad RS-232  Wedge keyboard solution
Storm Keyboard / Keypad RS-232 Wedge keyboard solution
 
Bill redirect field
Bill redirect fieldBill redirect field
Bill redirect field
 
Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...
Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...
Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...
 

Similar to RS232 barcode scanner Proximity reader on a specific field in your application

Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)
Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)
Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)topomax
 
RS232 USB Balance and Scale Software
RS232 USB Balance and Scale SoftwareRS232 USB Balance and Scale Software
RS232 USB Balance and Scale Softwaretopomax
 
Automatic dimmer package dimensioning RS-232
Automatic dimmer package dimensioning RS-232Automatic dimmer package dimensioning RS-232
Automatic dimmer package dimensioning RS-232topomax
 
Control relay via schedule time
Control relay via schedule timeControl relay via schedule time
Control relay via schedule timetopomax
 
How support caller ID phone number
How support caller ID phone numberHow support caller ID phone number
How support caller ID phone numbertopomax
 
Bill redirect manual
Bill redirect manualBill redirect manual
Bill redirect manualtopomax
 
Serial RS232 to Keyboard wedge software
Serial RS232 to Keyboard wedge softwareSerial RS232 to Keyboard wedge software
Serial RS232 to Keyboard wedge softwaretopomax
 
www_nasdaq_com_markets_ipos_filing_ashx_filingid_1166903
www_nasdaq_com_markets_ipos_filing_ashx_filingid_1166903www_nasdaq_com_markets_ipos_filing_ashx_filingid_1166903
www_nasdaq_com_markets_ipos_filing_ashx_filingid_1166903Jovan Hutton Pulitzer™
 
Notes how to work with variables, constants and do calculations
Notes how to work with variables, constants and do calculationsNotes how to work with variables, constants and do calculations
Notes how to work with variables, constants and do calculationsWilliam Olivier
 
Bill serial monitor_manual_en
Bill serial monitor_manual_enBill serial monitor_manual_en
Bill serial monitor_manual_endanysaju_1
 
Copying number ranges in SAP FICO ECC
Copying number ranges  in SAP FICO ECCCopying number ranges  in SAP FICO ECC
Copying number ranges in SAP FICO ECCSrinivas Rao
 
FlexNet Delivery and FlexNet Operations On-Demand Tips & Tricks
FlexNet Delivery and FlexNet Operations On-Demand Tips & TricksFlexNet Delivery and FlexNet Operations On-Demand Tips & Tricks
FlexNet Delivery and FlexNet Operations On-Demand Tips & TricksFlexera
 
Sapphire 2013 Presentation - Streamlining SAP Transactions for Barcode Scanne...
Sapphire 2013 Presentation - Streamlining SAP Transactions for Barcode Scanne...Sapphire 2013 Presentation - Streamlining SAP Transactions for Barcode Scanne...
Sapphire 2013 Presentation - Streamlining SAP Transactions for Barcode Scanne...DeeDee Kato
 
Bill redirect multiply
Bill redirect multiplyBill redirect multiply
Bill redirect multiplytopomax
 
Cucm bk b1000_f29_00_be6k-install-guide-10
Cucm bk b1000_f29_00_be6k-install-guide-10Cucm bk b1000_f29_00_be6k-install-guide-10
Cucm bk b1000_f29_00_be6k-install-guide-10용원 이
 
Cucm bk b1000_f29_00_be6k-install-guide-10
Cucm bk b1000_f29_00_be6k-install-guide-10Cucm bk b1000_f29_00_be6k-install-guide-10
Cucm bk b1000_f29_00_be6k-install-guide-10용원 이
 
Developing Applications with the IoT Button - DevDay Austin 2017
Developing Applications with the IoT Button - DevDay Austin 2017Developing Applications with the IoT Button - DevDay Austin 2017
Developing Applications with the IoT Button - DevDay Austin 2017Amazon Web Services
 
Watson IoT @Ryerson University - IEEE Chapter
Watson IoT  @Ryerson University - IEEE Chapter  Watson IoT  @Ryerson University - IEEE Chapter
Watson IoT @Ryerson University - IEEE Chapter Markus Van Kempen
 
IBM iSeries Terminal Based Performance Testing with Rational Performance Tester
IBM iSeries Terminal Based Performance Testing with Rational Performance TesterIBM iSeries Terminal Based Performance Testing with Rational Performance Tester
IBM iSeries Terminal Based Performance Testing with Rational Performance TesterWinton Winton
 

Similar to RS232 barcode scanner Proximity reader on a specific field in your application (20)

Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)
Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)
Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)
 
RS232 USB Balance and Scale Software
RS232 USB Balance and Scale SoftwareRS232 USB Balance and Scale Software
RS232 USB Balance and Scale Software
 
Automatic dimmer package dimensioning RS-232
Automatic dimmer package dimensioning RS-232Automatic dimmer package dimensioning RS-232
Automatic dimmer package dimensioning RS-232
 
Control relay via schedule time
Control relay via schedule timeControl relay via schedule time
Control relay via schedule time
 
How support caller ID phone number
How support caller ID phone numberHow support caller ID phone number
How support caller ID phone number
 
Bill redirect manual
Bill redirect manualBill redirect manual
Bill redirect manual
 
Serial RS232 to Keyboard wedge software
Serial RS232 to Keyboard wedge softwareSerial RS232 to Keyboard wedge software
Serial RS232 to Keyboard wedge software
 
Zoom user manual
Zoom user manualZoom user manual
Zoom user manual
 
www_nasdaq_com_markets_ipos_filing_ashx_filingid_1166903
www_nasdaq_com_markets_ipos_filing_ashx_filingid_1166903www_nasdaq_com_markets_ipos_filing_ashx_filingid_1166903
www_nasdaq_com_markets_ipos_filing_ashx_filingid_1166903
 
Notes how to work with variables, constants and do calculations
Notes how to work with variables, constants and do calculationsNotes how to work with variables, constants and do calculations
Notes how to work with variables, constants and do calculations
 
Bill serial monitor_manual_en
Bill serial monitor_manual_enBill serial monitor_manual_en
Bill serial monitor_manual_en
 
Copying number ranges in SAP FICO ECC
Copying number ranges  in SAP FICO ECCCopying number ranges  in SAP FICO ECC
Copying number ranges in SAP FICO ECC
 
FlexNet Delivery and FlexNet Operations On-Demand Tips & Tricks
FlexNet Delivery and FlexNet Operations On-Demand Tips & TricksFlexNet Delivery and FlexNet Operations On-Demand Tips & Tricks
FlexNet Delivery and FlexNet Operations On-Demand Tips & Tricks
 
Sapphire 2013 Presentation - Streamlining SAP Transactions for Barcode Scanne...
Sapphire 2013 Presentation - Streamlining SAP Transactions for Barcode Scanne...Sapphire 2013 Presentation - Streamlining SAP Transactions for Barcode Scanne...
Sapphire 2013 Presentation - Streamlining SAP Transactions for Barcode Scanne...
 
Bill redirect multiply
Bill redirect multiplyBill redirect multiply
Bill redirect multiply
 
Cucm bk b1000_f29_00_be6k-install-guide-10
Cucm bk b1000_f29_00_be6k-install-guide-10Cucm bk b1000_f29_00_be6k-install-guide-10
Cucm bk b1000_f29_00_be6k-install-guide-10
 
Cucm bk b1000_f29_00_be6k-install-guide-10
Cucm bk b1000_f29_00_be6k-install-guide-10Cucm bk b1000_f29_00_be6k-install-guide-10
Cucm bk b1000_f29_00_be6k-install-guide-10
 
Developing Applications with the IoT Button - DevDay Austin 2017
Developing Applications with the IoT Button - DevDay Austin 2017Developing Applications with the IoT Button - DevDay Austin 2017
Developing Applications with the IoT Button - DevDay Austin 2017
 
Watson IoT @Ryerson University - IEEE Chapter
Watson IoT  @Ryerson University - IEEE Chapter  Watson IoT  @Ryerson University - IEEE Chapter
Watson IoT @Ryerson University - IEEE Chapter
 
IBM iSeries Terminal Based Performance Testing with Rational Performance Tester
IBM iSeries Terminal Based Performance Testing with Rational Performance TesterIBM iSeries Terminal Based Performance Testing with Rational Performance Tester
IBM iSeries Terminal Based Performance Testing with Rational Performance Tester
 

RS232 barcode scanner Proximity reader on a specific field in your application

  • 1. Bill Redirect Transfer serial barcode data as keystrokes into your Windows applications. Into a specific field (as if it was typed in using the keyboard) Documentation: 17/12/2008 Use this documentation with the product : Bill Redirect 5.0M and more Software configuration and integration service It's free, fast, and efficient ! Submit your case to info@billproduction.com and receive a customized answer ! Our Internet site: http://www.billproduction.com/ Email: info@BillProduction.com
  • 2. This documentation demonstrate how Transfer serial barcode data as keystrokes into your Windows applications. Into a specific field The following instructions apply to all Serial Port (RS-232) Barcode Readers and USB Barcode Reader that supports Com Port Emulation Step #1 Download and install Bill Redirect software 5.0M or more http://www.billproduction.com/Bill_COMtoKB.ZIP Step #2 Disable all except the Serial Port and Keyboard Buffer section. Set to OFF Serial Port and Pressed key switch.
  • 3. Step #3 Click on button: Configuration. Enter the Serial Port Number where your Barcode reader is connected. Serial Port Configuration: Enter the configuration of your Barcode Reader.
  • 4. Step #4 To open the “Mouse Position” window Enter in the field Password: Mouse Open your application Move the mouse pointer on the field where the data should be sent. Click on this field and take in “Position on the Window” For this example: 3165 and 990
  • 5. Step #5 Click on button: Configuration Click on button: ADD Enter in this field: {ALL_RX} Enter in this field: APP[Shop Floor]{MOUSE_ACTION[3165,990,WINDOW,LEFT_CLICK]}RX_DATA In this string 3165,990, is the field position noted before In this string Shop Floor is your application name * You can enter just a part of the title, for example if the title is “Shop Floor Data Collection” you can enter just a part of the title for example: Shop Floor
  • 6. Step #6 Click on button: OK Click on button: Save Configuration TEST For more information, consult the product manual: http://www.billproduction.com/Bill_Redirect_Manual.pdf