TECHNICAL DATA SHEET
Designation code under EN 13164:
XPS – abbreviation for EXTRUDED POLYSTYRENE
EN 13164 – number of the European standard for extruded polystyrene thermal insulation material
Ti – declared level of thickness tolerance
CS(10Y) – declared compressive strength at 10% deformation
DS(TH) – declared rate of dimensional stability under specified temperature and humidity conditions
TRi – Tensile strength perpendicular to faces σm
WL(T)i – declared rate of long-term water absorption by immersion
WD(V)i – declared rate of long-term water absorption by diffusion
MUi – declared water vapor diffusion resistance factor
Description
FIBRANxps 300-L, is a thermal insulation board made of extruded polystyrene, having a smooth surface and edges in the shape of
letter “L” to prevent the formation of thermal bridges.
Applications
• Inverted warm flat roofs
• DUO roofs (low energy and passive houses)
• PLUS roofs (renovations, energy – class upgrade)
• Warm flat roofs
• Green roofs
• Roof terraces
• Floors between storeys
• Basement floors
• Floor heating
• Extra loaded floors
• Cold rooms
• Skating rings
• Hanging façades (ventilated rain screen cladding)
• Perimeter basement walls, even if ground water is present
• Swimming pools
Quality
Products are tested in accordance with:
• EN 13164,
• EN 13501-1,
• EN ISO 11925-2: 2002
At the following notified laboratory:
• ZAG Ljubljana
• FIW München
• MPA BAU Hannover
Environmental protection
• Products FIBRANxps are produced with environmentally friendly blowing agents
• 100% recyclable
Technical Characteristics
XPS – EN 13164 – T1 – CS(10)300– DS(TH) – DLT(2)5 – WL(T)0,7 – WD(V)3 – FT2
Properties Measure units EN standard 300-L
Shape of profile L
Surface Smooth
Board dimension mm ΕΝ 822 1250/600
Thickness tolerance ΕΝ 823 Τ1
Declared value of compressive strength at 10%
deformation
kPa ΕΝ 826 300
20mm≤d≤30mm 0,033Declared thermal
conductivity (after 25 years) 40mm≤d≤200mm
W/(m*K) ΕΝ 12667
0,035
Long term water absorption
by immersion
Smooth surface vol. % ΕΝ 12087 0,3
Water absorption by diffusion vol. % ΕΝ 12088 1,5
Water vapour diffusion resistance factor - ΕΝ 12086 150-50
Temperature of use °C From -50 to +75
Reaction to fire Class ΕΝ 13501-1 Ε
300-L
TECHNICAL DATA SHEET
The technical data and instructions included in this technical data sheet is the result of knowledge and experience from the company’s R & D
department as well as from the application of the product in practice. Recommendations and suggestions on the use of materials are made without
guarantee, since the current conditions during the application are beyond the control of our company. The application, use and processing of products
are beyond our control and therefore entirely your own responsibility. For this reason it is the user's responsibility to ensure that the material is suitable
for the intended use and conditions of the project. The issue of this technical brochure invalidates any prior version for the same product.
DATE.: 10/06/2011 VERS. 2 Central Office
6
ο
Km Thessaloniki - Oreokastro
P.O. BOX 40306, ZIP CODE 560 10
Tel. +30 2310 682 425 Web site:www.fibran.com
Fax. +30 2310 683 13 e-mail: info@fibran.com
Packaging
thickness [mm]
width
[mm]
length
[mm]
boards in a package
[pieces]
quantity in a package
[m
2
]
30 600 1250 14 10,50
40 600 1250 10 7,50
50 600 1250 8 6,00
60 600 1250 7 5,25
80 600 1250 5 3,75
100 600 1250 4 3,00
120 600 1250 3 2,25
140 600 1250 3 2,25
160 600 1250 2 1,50
180 600 1250 2 1,50
200 600 1250 2 1,50
Instructions for use
STORAGE AND HANDLING
FIBRANxps thermal insulation boards are resistant to cold, rain and snow, but not to long-term exposure to ultra-violet radiation, such as that caused by
direct sunlight. The boards therefore need to be handled with care, and the protective foil should only be removed just before installation. Should
FIBRANxps boards lose their original foil, they must be re-protected as quickly as possible.
Although FIBRANxps boards are among the toughest thermal insulation boards on the market, contact with hard objects or surfaces can damage or
deform them.
FIBRANxps boards may be used up to a maximum temperature of 75°C. However, if they are stored in the open air, and exposed to direct sunlight or
covered with dark foil, they may deform due to the resulting high temperatures.
FIBRANxps boards must not come into contact with solvents such as petrol, tar and formic acid, or with gases such as methane, ethane, propane and
butane. If they are to be fixed using an adhesive, it is recommended that the material’s resistance to it be first tested. Please consult our technical
department if necessary. FIBRANxps boards are moderately resistant to substances such as mineral and food oils, paraffin, phenol and fats, which
means that long-term exposure to these substances may affect the appearance or structure of its surface.
FIBRANxps boards are highly resistant to bitumen, lime, cement, plaster, sea-water, lyes, bleaches, most acids, inorganic gases, alcohol, and silicon.
In doubtful cases it is recommended that a preliminary test be performed.
APPLICATION
During the installation of FIBRANxps boards all design requirements should be taken into account.
FIBRANxps boards should be applied to flat and clean surfaces. They can be easily cut with a sharp knife, a saw or a hot wire device.
Most edges of FIBRANxps products are rebated (L cut) or tongued-and-grooved (D cut). The boards are usually installed in a single layer. Double-layer
application is desirable for boards with square (I) edges, thus preventing the formation of thermal bridges at joints. Thermal insulation boards must be
fitted to inverted flat roofs in a single layer.
Naked flames must not be used during the installation of FIBRANxps boards. Where they are to be applied to waterproof membranes on basement
walls, they should be fixed with special FIBRANstick sticker pads made of butyl rubber. In the presence of ground water the adhesive (e.g. a bitumen
product) should be spread over the wall’s entire surface.
When using FIBRANxps thermal insulation on larger surfaces, especially on warm flat roofs, expansion or contraction of the boards due to temperature
changes should be taken into account. In these situations the inclusion of expansion joints made of mineral wool is recommended.
PROTECTION DURING APPLICATION
It is recommended that operatives cutting FIBRANxps boards by a wire in confined spaces wear protective respiratory masks and eye goggles.

More Related Content

What's hot

Quicki branch joint - 25mm to 16mm
Quicki branch joint - 25mm to 16mmQuicki branch joint - 25mm to 16mm
Quicki branch joint - 25mm to 16mmCable Glands UK Ltd
 
Faqs December 2017 - Teflon Nonstick Coatings
Faqs December 2017 - Teflon Nonstick CoatingsFaqs December 2017 - Teflon Nonstick Coatings
Faqs December 2017 - Teflon Nonstick CoatingsCoatresa
 
Thermobreak Thermaloc - Brochure 270814 D
Thermobreak Thermaloc - Brochure 270814 DThermobreak Thermaloc - Brochure 270814 D
Thermobreak Thermaloc - Brochure 270814 DGary Haydon
 
Ultra Universal Pipe Wrap & Universal Pipe Sleeve Brochure
Ultra Universal Pipe Wrap & Universal Pipe Sleeve BrochureUltra Universal Pipe Wrap & Universal Pipe Sleeve Brochure
Ultra Universal Pipe Wrap & Universal Pipe Sleeve BrochureSIG Technical Insulation
 
EPDM Pressure-Sensitive Elastoform Flashing
EPDM Pressure-Sensitive Elastoform Flashing EPDM Pressure-Sensitive Elastoform Flashing
EPDM Pressure-Sensitive Elastoform Flashing Victoria Crocitto
 
Econocal_econotherm Web PDF 07 May 2013
Econocal_econotherm Web PDF 07 May 2013Econocal_econotherm Web PDF 07 May 2013
Econocal_econotherm Web PDF 07 May 2013Janine Course
 
BROAERO_Aerolon Brochure
BROAERO_Aerolon BrochureBROAERO_Aerolon Brochure
BROAERO_Aerolon BrochureKa Man Tang
 
householders-guide-to-flat-roofing-2015
householders-guide-to-flat-roofing-2015householders-guide-to-flat-roofing-2015
householders-guide-to-flat-roofing-2015Vin Housley
 
Fire Safety and Performance of Wood
Fire Safety and Performance of WoodFire Safety and Performance of Wood
Fire Safety and Performance of WoodFWPA
 
Peter Cox - Drywall Damp Proofing
Peter Cox - Drywall Damp ProofingPeter Cox - Drywall Damp Proofing
Peter Cox - Drywall Damp ProofingKevin Ball
 

What's hot (17)

Quicki branch joint - 25mm to 16mm
Quicki branch joint - 25mm to 16mmQuicki branch joint - 25mm to 16mm
Quicki branch joint - 25mm to 16mm
 
Faqs December 2017 - Teflon Nonstick Coatings
Faqs December 2017 - Teflon Nonstick CoatingsFaqs December 2017 - Teflon Nonstick Coatings
Faqs December 2017 - Teflon Nonstick Coatings
 
Thermobreak Thermaloc - Brochure 270814 D
Thermobreak Thermaloc - Brochure 270814 DThermobreak Thermaloc - Brochure 270814 D
Thermobreak Thermaloc - Brochure 270814 D
 
En13501 fireproof magnesium oxide board for drywall
En13501 fireproof magnesium oxide board for drywallEn13501 fireproof magnesium oxide board for drywall
En13501 fireproof magnesium oxide board for drywall
 
3M Fire Barrier Intumescent Sealant - 3M CP25WB+
3M Fire Barrier Intumescent Sealant - 3M CP25WB+3M Fire Barrier Intumescent Sealant - 3M CP25WB+
3M Fire Barrier Intumescent Sealant - 3M CP25WB+
 
Waterguard membrane epdm
Waterguard membrane epdmWaterguard membrane epdm
Waterguard membrane epdm
 
Fireboard calcium silicate
Fireboard calcium silicateFireboard calcium silicate
Fireboard calcium silicate
 
Ultra Universal Pipe Wrap & Universal Pipe Sleeve Brochure
Ultra Universal Pipe Wrap & Universal Pipe Sleeve BrochureUltra Universal Pipe Wrap & Universal Pipe Sleeve Brochure
Ultra Universal Pipe Wrap & Universal Pipe Sleeve Brochure
 
EPDM Pressure-Sensitive Elastoform Flashing
EPDM Pressure-Sensitive Elastoform Flashing EPDM Pressure-Sensitive Elastoform Flashing
EPDM Pressure-Sensitive Elastoform Flashing
 
Econocal_econotherm Web PDF 07 May 2013
Econocal_econotherm Web PDF 07 May 2013Econocal_econotherm Web PDF 07 May 2013
Econocal_econotherm Web PDF 07 May 2013
 
BROAERO_Aerolon Brochure
BROAERO_Aerolon BrochureBROAERO_Aerolon Brochure
BROAERO_Aerolon Brochure
 
3M Fire Barrier Intumescent Wrap - 3M FS195+
3M Fire Barrier Intumescent Wrap - 3M FS195+3M Fire Barrier Intumescent Wrap - 3M FS195+
3M Fire Barrier Intumescent Wrap - 3M FS195+
 
Fire Protection
Fire ProtectionFire Protection
Fire Protection
 
FiloSeal+HD FIRE
FiloSeal+HD FIRE FiloSeal+HD FIRE
FiloSeal+HD FIRE
 
householders-guide-to-flat-roofing-2015
householders-guide-to-flat-roofing-2015householders-guide-to-flat-roofing-2015
householders-guide-to-flat-roofing-2015
 
Fire Safety and Performance of Wood
Fire Safety and Performance of WoodFire Safety and Performance of Wood
Fire Safety and Performance of Wood
 
Peter Cox - Drywall Damp Proofing
Peter Cox - Drywall Damp ProofingPeter Cox - Drywall Damp Proofing
Peter Cox - Drywall Damp Proofing
 

Viewers also liked

9 Common mistakes
9 Common mistakes9 Common mistakes
9 Common mistakesSrishanbid
 
Estructura y-dinamica-de-la-comunidad-potencial-educativo-de-las-comunidades-...
Estructura y-dinamica-de-la-comunidad-potencial-educativo-de-las-comunidades-...Estructura y-dinamica-de-la-comunidad-potencial-educativo-de-las-comunidades-...
Estructura y-dinamica-de-la-comunidad-potencial-educativo-de-las-comunidades-...Marily Dominguez Soto
 
Leb Buerokommunikation Umschulung
Leb Buerokommunikation Umschulung Leb Buerokommunikation Umschulung
Leb Buerokommunikation Umschulung Heiko Idensen
 
Miley Cyrus : Pop Princess
Miley Cyrus : Pop PrincessMiley Cyrus : Pop Princess
Miley Cyrus : Pop Princesstamarambrown
 
Proyecto mie informatica
Proyecto mie informaticaProyecto mie informatica
Proyecto mie informaticaFerBraz21
 
Basel III - Implications of Implementation
Basel III - Implications of ImplementationBasel III - Implications of Implementation
Basel III - Implications of ImplementationDavid Kyson
 
Salon b 17 kasim 2011 16.10 16.30 hakan seçkin
Salon b 17 kasim 2011 16.10 16.30 hakan seçkinSalon b 17 kasim 2011 16.10 16.30 hakan seçkin
Salon b 17 kasim 2011 16.10 16.30 hakan seçkintyfngnc
 
CUADRO PROYECTO DE INVESTIGACIÓN
CUADRO PROYECTO DE INVESTIGACIÓNCUADRO PROYECTO DE INVESTIGACIÓN
CUADRO PROYECTO DE INVESTIGACIÓNEtna Lorena
 
Visuals_16.6_Jinhongahn_rev
Visuals_16.6_Jinhongahn_revVisuals_16.6_Jinhongahn_rev
Visuals_16.6_Jinhongahn_revJinhong Ahn
 
Proyecto conociendo aprendo 1
Proyecto conociendo aprendo 1Proyecto conociendo aprendo 1
Proyecto conociendo aprendo 1andreajuana
 
Recalde alejandro
Recalde alejandroRecalde alejandro
Recalde alejandroAlejandrodr
 
PROYECTO DE INVESTIGACION
PROYECTO DE INVESTIGACIONPROYECTO DE INVESTIGACION
PROYECTO DE INVESTIGACIONEtna Lorena
 

Viewers also liked (20)

23
2323
23
 
9 Common mistakes
9 Common mistakes9 Common mistakes
9 Common mistakes
 
Estructura y-dinamica-de-la-comunidad-potencial-educativo-de-las-comunidades-...
Estructura y-dinamica-de-la-comunidad-potencial-educativo-de-las-comunidades-...Estructura y-dinamica-de-la-comunidad-potencial-educativo-de-las-comunidades-...
Estructura y-dinamica-de-la-comunidad-potencial-educativo-de-las-comunidades-...
 
Leb Buerokommunikation Umschulung
Leb Buerokommunikation Umschulung Leb Buerokommunikation Umschulung
Leb Buerokommunikation Umschulung
 
Miley Cyrus : Pop Princess
Miley Cyrus : Pop PrincessMiley Cyrus : Pop Princess
Miley Cyrus : Pop Princess
 
Proyecto mie informatica
Proyecto mie informaticaProyecto mie informatica
Proyecto mie informatica
 
Basel III - Implications of Implementation
Basel III - Implications of ImplementationBasel III - Implications of Implementation
Basel III - Implications of Implementation
 
Salon b 17 kasim 2011 16.10 16.30 hakan seçkin
Salon b 17 kasim 2011 16.10 16.30 hakan seçkinSalon b 17 kasim 2011 16.10 16.30 hakan seçkin
Salon b 17 kasim 2011 16.10 16.30 hakan seçkin
 
Horas
Horas Horas
Horas
 
PROPAK15-Postshow
PROPAK15-PostshowPROPAK15-Postshow
PROPAK15-Postshow
 
Noticia 1
Noticia 1Noticia 1
Noticia 1
 
Improve life through QSB
Improve life through QSBImprove life through QSB
Improve life through QSB
 
CUADRO PROYECTO DE INVESTIGACIÓN
CUADRO PROYECTO DE INVESTIGACIÓNCUADRO PROYECTO DE INVESTIGACIÓN
CUADRO PROYECTO DE INVESTIGACIÓN
 
Visuals_16.6_Jinhongahn_rev
Visuals_16.6_Jinhongahn_revVisuals_16.6_Jinhongahn_rev
Visuals_16.6_Jinhongahn_rev
 
Raul avila
Raul avilaRaul avila
Raul avila
 
Notas J
Notas JNotas J
Notas J
 
Proyecto conociendo aprendo 1
Proyecto conociendo aprendo 1Proyecto conociendo aprendo 1
Proyecto conociendo aprendo 1
 
Símbolos Patrios
Símbolos PatriosSímbolos Patrios
Símbolos Patrios
 
Recalde alejandro
Recalde alejandroRecalde alejandro
Recalde alejandro
 
PROYECTO DE INVESTIGACION
PROYECTO DE INVESTIGACIONPROYECTO DE INVESTIGACION
PROYECTO DE INVESTIGACION
 

Similar to 300 l eng-com (20)

Waterproofing copmound
Waterproofing copmoundWaterproofing copmound
Waterproofing copmound
 
Cat. Solexin_english_4
Cat. Solexin_english_4Cat. Solexin_english_4
Cat. Solexin_english_4
 
Car Park Protection - Mariseal 250 Flash
Car Park Protection - Mariseal 250 FlashCar Park Protection - Mariseal 250 Flash
Car Park Protection - Mariseal 250 Flash
 
Cool Roof Paint
Cool Roof PaintCool Roof Paint
Cool Roof Paint
 
Seamless Polyurethane Concrete - Mariseal System
Seamless Polyurethane Concrete - Mariseal SystemSeamless Polyurethane Concrete - Mariseal System
Seamless Polyurethane Concrete - Mariseal System
 
RIW Flexiseal
RIW Flexiseal RIW Flexiseal
RIW Flexiseal
 
RIW Structureseal -Sodium Bentonite System - Typical Details
RIW Structureseal -Sodium Bentonite System - Typical DetailsRIW Structureseal -Sodium Bentonite System - Typical Details
RIW Structureseal -Sodium Bentonite System - Typical Details
 
Tripolux - Insulation Products
Tripolux - Insulation ProductsTripolux - Insulation Products
Tripolux - Insulation Products
 
Dpc in foundation
Dpc in foundationDpc in foundation
Dpc in foundation
 
ISOMAT_Waterproofing
ISOMAT_WaterproofingISOMAT_Waterproofing
ISOMAT_Waterproofing
 
wintech.pdf
wintech.pdfwintech.pdf
wintech.pdf
 
Hvac insulation
Hvac insulationHvac insulation
Hvac insulation
 
Liquid Asphaltic Composition (LAC) - RIW
Liquid Asphaltic Composition (LAC) - RIW Liquid Asphaltic Composition (LAC) - RIW
Liquid Asphaltic Composition (LAC) - RIW
 
ACH 121 Lecture 11a (Thermal & Moisture Protection)
ACH 121 Lecture 11a (Thermal & Moisture Protection)ACH 121 Lecture 11a (Thermal & Moisture Protection)
ACH 121 Lecture 11a (Thermal & Moisture Protection)
 
Tobslak tbyrothane 1 k
Tobslak tbyrothane 1 kTobslak tbyrothane 1 k
Tobslak tbyrothane 1 k
 
Tron flex
Tron  flexTron  flex
Tron flex
 
Waterguard cool cool
Waterguard cool coolWaterguard cool cool
Waterguard cool cool
 
Waterguard cool cool
Waterguard cool coolWaterguard cool cool
Waterguard cool cool
 
Belzona
BelzonaBelzona
Belzona
 
impact brochure
impact brochureimpact brochure
impact brochure
 

More from Salah Hammami

Soudage2 170322110328
Soudage2 170322110328Soudage2 170322110328
Soudage2 170322110328Salah Hammami
 
Cours technologie electrique pneumatique
Cours technologie electrique   pneumatiqueCours technologie electrique   pneumatique
Cours technologie electrique pneumatiqueSalah Hammami
 
Allemand 141227133852-conversion-gate02
Allemand 141227133852-conversion-gate02Allemand 141227133852-conversion-gate02
Allemand 141227133852-conversion-gate02Salah Hammami
 
2011 05-instrumentationetrgulation-120627023358-phpapp02 (1)
2011 05-instrumentationetrgulation-120627023358-phpapp02 (1)2011 05-instrumentationetrgulation-120627023358-phpapp02 (1)
2011 05-instrumentationetrgulation-120627023358-phpapp02 (1)Salah Hammami
 
0fcfd50f97284d4b31000000
0fcfd50f97284d4b310000000fcfd50f97284d4b31000000
0fcfd50f97284d4b31000000Salah Hammami
 
0fcfd50f97284d4b31000000 (1)
0fcfd50f97284d4b31000000 (1)0fcfd50f97284d4b31000000 (1)
0fcfd50f97284d4b31000000 (1)Salah Hammami
 
Chap 5 amplificateur opérationnel
Chap 5 amplificateur opérationnelChap 5 amplificateur opérationnel
Chap 5 amplificateur opérationnelSalah Hammami
 
02e7e5284f777d06ed000000
02e7e5284f777d06ed00000002e7e5284f777d06ed000000
02e7e5284f777d06ed000000Salah Hammami
 
0fcfd50f97284d4b31000000
0fcfd50f97284d4b310000000fcfd50f97284d4b31000000
0fcfd50f97284d4b31000000Salah Hammami
 
0fcfd50f97284d4b31000000 (1)
0fcfd50f97284d4b31000000 (1)0fcfd50f97284d4b31000000 (1)
0fcfd50f97284d4b31000000 (1)Salah Hammami
 

More from Salah Hammami (11)

Soudage2 170322110328
Soudage2 170322110328Soudage2 170322110328
Soudage2 170322110328
 
Cours technologie electrique pneumatique
Cours technologie electrique   pneumatiqueCours technologie electrique   pneumatique
Cours technologie electrique pneumatique
 
Allemand 141227133852-conversion-gate02
Allemand 141227133852-conversion-gate02Allemand 141227133852-conversion-gate02
Allemand 141227133852-conversion-gate02
 
2011 05-instrumentationetrgulation-120627023358-phpapp02 (1)
2011 05-instrumentationetrgulation-120627023358-phpapp02 (1)2011 05-instrumentationetrgulation-120627023358-phpapp02 (1)
2011 05-instrumentationetrgulation-120627023358-phpapp02 (1)
 
0fcfd50f97284d4b31000000
0fcfd50f97284d4b310000000fcfd50f97284d4b31000000
0fcfd50f97284d4b31000000
 
0fcfd50f97284d4b31000000 (1)
0fcfd50f97284d4b31000000 (1)0fcfd50f97284d4b31000000 (1)
0fcfd50f97284d4b31000000 (1)
 
Chap 5 amplificateur opérationnel
Chap 5 amplificateur opérationnelChap 5 amplificateur opérationnel
Chap 5 amplificateur opérationnel
 
300 l eng-com
300 l eng-com300 l eng-com
300 l eng-com
 
02e7e5284f777d06ed000000
02e7e5284f777d06ed00000002e7e5284f777d06ed000000
02e7e5284f777d06ed000000
 
0fcfd50f97284d4b31000000
0fcfd50f97284d4b310000000fcfd50f97284d4b31000000
0fcfd50f97284d4b31000000
 
0fcfd50f97284d4b31000000 (1)
0fcfd50f97284d4b31000000 (1)0fcfd50f97284d4b31000000 (1)
0fcfd50f97284d4b31000000 (1)
 

300 l eng-com

  • 1. 300-L TECHNICAL DATA SHEET Designation code under EN 13164: XPS – abbreviation for EXTRUDED POLYSTYRENE EN 13164 – number of the European standard for extruded polystyrene thermal insulation material Ti – declared level of thickness tolerance CS(10Y) – declared compressive strength at 10% deformation DS(TH) – declared rate of dimensional stability under specified temperature and humidity conditions TRi – Tensile strength perpendicular to faces σm WL(T)i – declared rate of long-term water absorption by immersion WD(V)i – declared rate of long-term water absorption by diffusion MUi – declared water vapor diffusion resistance factor Description FIBRANxps 300-L, is a thermal insulation board made of extruded polystyrene, having a smooth surface and edges in the shape of letter “L” to prevent the formation of thermal bridges. Applications • Inverted warm flat roofs • DUO roofs (low energy and passive houses) • PLUS roofs (renovations, energy – class upgrade) • Warm flat roofs • Green roofs • Roof terraces • Floors between storeys • Basement floors • Floor heating • Extra loaded floors • Cold rooms • Skating rings • Hanging façades (ventilated rain screen cladding) • Perimeter basement walls, even if ground water is present • Swimming pools Quality Products are tested in accordance with: • EN 13164, • EN 13501-1, • EN ISO 11925-2: 2002 At the following notified laboratory: • ZAG Ljubljana • FIW München • MPA BAU Hannover Environmental protection • Products FIBRANxps are produced with environmentally friendly blowing agents • 100% recyclable Technical Characteristics XPS – EN 13164 – T1 – CS(10)300– DS(TH) – DLT(2)5 – WL(T)0,7 – WD(V)3 – FT2 Properties Measure units EN standard 300-L Shape of profile L Surface Smooth Board dimension mm ΕΝ 822 1250/600 Thickness tolerance ΕΝ 823 Τ1 Declared value of compressive strength at 10% deformation kPa ΕΝ 826 300 20mm≤d≤30mm 0,033Declared thermal conductivity (after 25 years) 40mm≤d≤200mm W/(m*K) ΕΝ 12667 0,035 Long term water absorption by immersion Smooth surface vol. % ΕΝ 12087 0,3 Water absorption by diffusion vol. % ΕΝ 12088 1,5 Water vapour diffusion resistance factor - ΕΝ 12086 150-50 Temperature of use °C From -50 to +75 Reaction to fire Class ΕΝ 13501-1 Ε
  • 2. 300-L TECHNICAL DATA SHEET The technical data and instructions included in this technical data sheet is the result of knowledge and experience from the company’s R & D department as well as from the application of the product in practice. Recommendations and suggestions on the use of materials are made without guarantee, since the current conditions during the application are beyond the control of our company. The application, use and processing of products are beyond our control and therefore entirely your own responsibility. For this reason it is the user's responsibility to ensure that the material is suitable for the intended use and conditions of the project. The issue of this technical brochure invalidates any prior version for the same product. DATE.: 10/06/2011 VERS. 2 Central Office 6 ο Km Thessaloniki - Oreokastro P.O. BOX 40306, ZIP CODE 560 10 Tel. +30 2310 682 425 Web site:www.fibran.com Fax. +30 2310 683 13 e-mail: info@fibran.com Packaging thickness [mm] width [mm] length [mm] boards in a package [pieces] quantity in a package [m 2 ] 30 600 1250 14 10,50 40 600 1250 10 7,50 50 600 1250 8 6,00 60 600 1250 7 5,25 80 600 1250 5 3,75 100 600 1250 4 3,00 120 600 1250 3 2,25 140 600 1250 3 2,25 160 600 1250 2 1,50 180 600 1250 2 1,50 200 600 1250 2 1,50 Instructions for use STORAGE AND HANDLING FIBRANxps thermal insulation boards are resistant to cold, rain and snow, but not to long-term exposure to ultra-violet radiation, such as that caused by direct sunlight. The boards therefore need to be handled with care, and the protective foil should only be removed just before installation. Should FIBRANxps boards lose their original foil, they must be re-protected as quickly as possible. Although FIBRANxps boards are among the toughest thermal insulation boards on the market, contact with hard objects or surfaces can damage or deform them. FIBRANxps boards may be used up to a maximum temperature of 75°C. However, if they are stored in the open air, and exposed to direct sunlight or covered with dark foil, they may deform due to the resulting high temperatures. FIBRANxps boards must not come into contact with solvents such as petrol, tar and formic acid, or with gases such as methane, ethane, propane and butane. If they are to be fixed using an adhesive, it is recommended that the material’s resistance to it be first tested. Please consult our technical department if necessary. FIBRANxps boards are moderately resistant to substances such as mineral and food oils, paraffin, phenol and fats, which means that long-term exposure to these substances may affect the appearance or structure of its surface. FIBRANxps boards are highly resistant to bitumen, lime, cement, plaster, sea-water, lyes, bleaches, most acids, inorganic gases, alcohol, and silicon. In doubtful cases it is recommended that a preliminary test be performed. APPLICATION During the installation of FIBRANxps boards all design requirements should be taken into account. FIBRANxps boards should be applied to flat and clean surfaces. They can be easily cut with a sharp knife, a saw or a hot wire device. Most edges of FIBRANxps products are rebated (L cut) or tongued-and-grooved (D cut). The boards are usually installed in a single layer. Double-layer application is desirable for boards with square (I) edges, thus preventing the formation of thermal bridges at joints. Thermal insulation boards must be fitted to inverted flat roofs in a single layer. Naked flames must not be used during the installation of FIBRANxps boards. Where they are to be applied to waterproof membranes on basement walls, they should be fixed with special FIBRANstick sticker pads made of butyl rubber. In the presence of ground water the adhesive (e.g. a bitumen product) should be spread over the wall’s entire surface. When using FIBRANxps thermal insulation on larger surfaces, especially on warm flat roofs, expansion or contraction of the boards due to temperature changes should be taken into account. In these situations the inclusion of expansion joints made of mineral wool is recommended. PROTECTION DURING APPLICATION It is recommended that operatives cutting FIBRANxps boards by a wire in confined spaces wear protective respiratory masks and eye goggles.