This document provides guidelines for reference dosimetry when using heavy ion beams for radiation therapy. It recommends using water phantoms and cylindrical or plane-parallel ionization chambers calibrated in Cobalt-60 beams. For dosimetry, the reference depth should be at the center of the spread-out Bragg peak where the dose slope is smallest. Corrections are needed for recombination effects which can be significant for pulsed beams. Values are provided for the kQ quality correction factor since primary standards are not available for heavy ion beams. Recommendations are given for beam quality specification, phantoms, chambers, and determination of absorbed dose to water in heavy ion beams.
CARCINOMA MAXILLARY SINUS MANAGEMENT RADIATION ONCOLOGYPaul George
This document discusses carcinoma of the maxilla, including epidemiology, histology, clinical presentation, staging, investigations, management, and prognosis. Squamous cell carcinoma is the most common type, presenting more in men in the 5th-6th decade. Clinical evaluation includes imaging like CT and MRI to determine extent. Treatment involves surgery like maxillectomy with clear margins followed by postoperative radiation therapy to improve outcomes. Prognosis remains poor at a 5-year survival of 35-45% even with multimodality treatment. A case example is presented of a 58-year-old female smoker found to have cT2N0M0 carcinoma of the left maxilla who underwent subtotal maxillectomy followed
بعد أن قام العلماء بتطوير أول أجهزة الحاسوب في الأربعينات أدرك المجتمع والعالم بأسره أن
هذه الأجهزة الجديدة سوف تقدم الكثير والكثير من الخدمات للبشرية كلها خاصة في مجال المعلومات
وتخزينها ومعالجتها واستعادتها، وبعد هذا التاريخ بعقد من الزمان بدأ الأطباء والمتخصصون بدورهم
في محاولة الاستفادة من هذه التقنيات بشكل حقيقي من خلال تطوير فكرة إدارة المعلومات ودور
الحاسب الآلي في الطب والرعاية الصحية، وكان من أهم ما تم تطويره بشكل مبكر فكرة السجلات
الطبية الإلكترونية التي تمثل عصب المعلومات المرتبطة بتقديم الرعاية الصحية للمريض محور كل
أنشطة الطب والرعاية الصحية، وقد تتابعت المراحل والتجارب التي مرت بها عملية التطوير لتلك
السجلات الطبية وتكاملها مع مصادر المعلومات المختلفة من خلال نظم شبكات المعلومات التي أدت
بالتبعية إلى فكرة اللامركزية واتصال المعلومات بين أكثر من مستشفى ومؤسسة طبية بل إلى أبعد من
ذلك من خلال شبكة الإنترنت التي دفعت إمكانياتها ملايين المستخدمين من المرضى إلى الاعتماد
عليها كمصدر للبحث عن المعلومات الطبية
Molecular imaging uses radiotracers and imaging modalities like PET and SPECT to non-invasively image biological processes at the molecular and cellular level. It has applications in both diagnostic imaging to locate targeted molecules involved in disease, as well as therapy to treat disease targets. PET provides higher resolution images while SPECT requires less equipment but has lower resolution. Both modalities detect emissions from radiotracers to construct 2D or 3D images showing the distribution of chemicals in the body.
This document provides guidelines for standardized calibration procedures for brachytherapy sources at secondary standards dosimetry laboratories (SSDLs) and hospitals. It discusses the calibration of 137Cs reference sources using cavity ionization chambers at SSDLs and hospitals. Procedures are described for calibrating brachytherapy sources such as high-dose rate (HDR) sources, low-dose rate (LDR) sources, and 125I seeds using well-type ionization chambers. Quality control procedures are also outlined to ensure safety and consistency in brachytherapy source calibrations.
Mlc;multi leaf collimators of variuos companieszahramansouri
This document discusses the three basic applications of multileaf collimators (MLCs) in radiation therapy: 1) replacing conventional blocking, 2) matching the beam's eye view to the planning target volume during arc rotation, and 3) achieving beam intensity modulation. It also describes the material properties of tungsten alloy that make it well-suited for MLC leaf construction, including its high density, hardness, low cost, and low coefficient of expansion. Finally, it briefly mentions mini MLCs and the MIMiC system.
This document provides guidelines for reference dosimetry when using heavy ion beams for radiation therapy. It recommends using water phantoms and cylindrical or plane-parallel ionization chambers calibrated in Cobalt-60 beams. For dosimetry, the reference depth should be at the center of the spread-out Bragg peak where the dose slope is smallest. Corrections are needed for recombination effects which can be significant for pulsed beams. Values are provided for the kQ quality correction factor since primary standards are not available for heavy ion beams. Recommendations are given for beam quality specification, phantoms, chambers, and determination of absorbed dose to water in heavy ion beams.
CARCINOMA MAXILLARY SINUS MANAGEMENT RADIATION ONCOLOGYPaul George
This document discusses carcinoma of the maxilla, including epidemiology, histology, clinical presentation, staging, investigations, management, and prognosis. Squamous cell carcinoma is the most common type, presenting more in men in the 5th-6th decade. Clinical evaluation includes imaging like CT and MRI to determine extent. Treatment involves surgery like maxillectomy with clear margins followed by postoperative radiation therapy to improve outcomes. Prognosis remains poor at a 5-year survival of 35-45% even with multimodality treatment. A case example is presented of a 58-year-old female smoker found to have cT2N0M0 carcinoma of the left maxilla who underwent subtotal maxillectomy followed
بعد أن قام العلماء بتطوير أول أجهزة الحاسوب في الأربعينات أدرك المجتمع والعالم بأسره أن
هذه الأجهزة الجديدة سوف تقدم الكثير والكثير من الخدمات للبشرية كلها خاصة في مجال المعلومات
وتخزينها ومعالجتها واستعادتها، وبعد هذا التاريخ بعقد من الزمان بدأ الأطباء والمتخصصون بدورهم
في محاولة الاستفادة من هذه التقنيات بشكل حقيقي من خلال تطوير فكرة إدارة المعلومات ودور
الحاسب الآلي في الطب والرعاية الصحية، وكان من أهم ما تم تطويره بشكل مبكر فكرة السجلات
الطبية الإلكترونية التي تمثل عصب المعلومات المرتبطة بتقديم الرعاية الصحية للمريض محور كل
أنشطة الطب والرعاية الصحية، وقد تتابعت المراحل والتجارب التي مرت بها عملية التطوير لتلك
السجلات الطبية وتكاملها مع مصادر المعلومات المختلفة من خلال نظم شبكات المعلومات التي أدت
بالتبعية إلى فكرة اللامركزية واتصال المعلومات بين أكثر من مستشفى ومؤسسة طبية بل إلى أبعد من
ذلك من خلال شبكة الإنترنت التي دفعت إمكانياتها ملايين المستخدمين من المرضى إلى الاعتماد
عليها كمصدر للبحث عن المعلومات الطبية
Molecular imaging uses radiotracers and imaging modalities like PET and SPECT to non-invasively image biological processes at the molecular and cellular level. It has applications in both diagnostic imaging to locate targeted molecules involved in disease, as well as therapy to treat disease targets. PET provides higher resolution images while SPECT requires less equipment but has lower resolution. Both modalities detect emissions from radiotracers to construct 2D or 3D images showing the distribution of chemicals in the body.
This document provides guidelines for standardized calibration procedures for brachytherapy sources at secondary standards dosimetry laboratories (SSDLs) and hospitals. It discusses the calibration of 137Cs reference sources using cavity ionization chambers at SSDLs and hospitals. Procedures are described for calibrating brachytherapy sources such as high-dose rate (HDR) sources, low-dose rate (LDR) sources, and 125I seeds using well-type ionization chambers. Quality control procedures are also outlined to ensure safety and consistency in brachytherapy source calibrations.
Mlc;multi leaf collimators of variuos companieszahramansouri
This document discusses the three basic applications of multileaf collimators (MLCs) in radiation therapy: 1) replacing conventional blocking, 2) matching the beam's eye view to the planning target volume during arc rotation, and 3) achieving beam intensity modulation. It also describes the material properties of tungsten alloy that make it well-suited for MLC leaf construction, including its high density, hardness, low cost, and low coefficient of expansion. Finally, it briefly mentions mini MLCs and the MIMiC system.
This document summarizes the goals and process of modeling treatment beams in a treatment planning system (TPS) during a radiation oncology rotation. The goals were to model one photon beam, one electron beam, and wedges, and then validate the modeled beams. Modeling involved collecting beam data, defining the machine and beams in the TPS, and fine-tuning parameters to match measured and computed dose distributions. Validation compared modeled and measured profiles, percent depth doses, and other dosimetric tests. The rotation provided an understanding of the nuances of TPS modeling.
Radiosurgery combines stereotactic techniques and radiation beams to precisely deliver a high dose of radiation to tumors and lesions. The Exactrac system allows for frameless radiosurgery using infrared cameras and x-ray imaging to track internal anatomy and automatically position the patient for treatment without an invasive head frame. Treatment planning involves delineating the target and nearby organs at risk, specifying dose constraints, and optimizing the plan to conform the high dose region to the tumor while sparing surrounding healthy tissue.
Radiation therapy uses radiation to damage and destroy cancer cells. It has been used to treat cancer for over 100 years. Modern radiation therapy is very precise and most patients receive it as part of their overall cancer treatment plan. Radiation therapy can cure cancer or reduce symptoms by shrinking tumors. While it causes some side effects, radiation is a generally safe and effective way to treat many types of cancer.
This document discusses various specialized radiographic techniques used in dentistry, including tomography, computed tomography (CT), cone beam computed tomography (CBCT), and magnetic resonance imaging (MRI). It provides details on the principles, advantages, disadvantages, and applications of each technique. Tomography aims to blur structures outside the focal plane. CT produces cross-sectional images using X-rays. CBCT uses a cone-shaped beam and has advantages of lower dose and cost compared to medical CT. MRI uses magnetic fields and radio waves to distinguish tissues without ionizing radiation. Each modality has indications for examining dental and craniofacial structures.
This document discusses head and neck PET/CT scans. It provides information on:
- The types of cancers that PET/CT scans are used for in the head and neck region.
- The superiority of PET/CT over CT and MRI for detecting lymph node involvement, distant metastases, and unknown primary cancers.
- The key applications of PET/CT including pretreatment staging, radiotherapy planning, monitoring treatment response, follow-up care, and detecting unknown primary cancers.
This document summarizes the goals and process of modeling treatment beams in a treatment planning system (TPS) during a radiation oncology rotation. The goals were to model one photon beam, one electron beam, and wedges, and then validate the modeled beams. Modeling involved collecting beam data, defining the machine and beams in the TPS, and fine-tuning parameters to match measured and computed dose distributions. Validation compared modeled and measured profiles, percent depth doses, and other dosimetric tests. The rotation provided an understanding of the nuances of TPS modeling.
Radiosurgery combines stereotactic techniques and radiation beams to precisely deliver a high dose of radiation to tumors and lesions. The Exactrac system allows for frameless radiosurgery using infrared cameras and x-ray imaging to track internal anatomy and automatically position the patient for treatment without an invasive head frame. Treatment planning involves delineating the target and nearby organs at risk, specifying dose constraints, and optimizing the plan to conform the high dose region to the tumor while sparing surrounding healthy tissue.
Radiation therapy uses radiation to damage and destroy cancer cells. It has been used to treat cancer for over 100 years. Modern radiation therapy is very precise and most patients receive it as part of their overall cancer treatment plan. Radiation therapy can cure cancer or reduce symptoms by shrinking tumors. While it causes some side effects, radiation is a generally safe and effective way to treat many types of cancer.
This document discusses various specialized radiographic techniques used in dentistry, including tomography, computed tomography (CT), cone beam computed tomography (CBCT), and magnetic resonance imaging (MRI). It provides details on the principles, advantages, disadvantages, and applications of each technique. Tomography aims to blur structures outside the focal plane. CT produces cross-sectional images using X-rays. CBCT uses a cone-shaped beam and has advantages of lower dose and cost compared to medical CT. MRI uses magnetic fields and radio waves to distinguish tissues without ionizing radiation. Each modality has indications for examining dental and craniofacial structures.
This document discusses head and neck PET/CT scans. It provides information on:
- The types of cancers that PET/CT scans are used for in the head and neck region.
- The superiority of PET/CT over CT and MRI for detecting lymph node involvement, distant metastases, and unknown primary cancers.
- The key applications of PET/CT including pretreatment staging, radiotherapy planning, monitoring treatment response, follow-up care, and detecting unknown primary cancers.
2. Stan równowagi
16_352
opis termodynamiczny
A A
∆G = 0
∆G° + RT ln(Q)=O B B
C
(a) (b)
wówczas
a) ∆G° <0, proces zmierza
∆G°= - RT ln(K) w określonym kierunku
K = stała równowagi b) Stan równowagi
osiągnięty gdy ∆G° =0
3. Stan równowagi
opis kinetyczny
Stan, w którym stężenia reagentów są stałe w czasie
N2(g) + 3H2(g) 2NH3(g)
13_315
Equilibrium
Concentration
H2
NH3
N2
Time
4. Stan równowagi
opis kinetyczny
Nie oznacza to, że reakcje nie biegną.
Równowaga ma charakter dynamiczny
Film1`równowaga dynamiczna NO2.MOV
6. Prawo działania mas
Sposoby wyrażania stałych równowag
xC ⋅ xD
c d
ułamek molowy
K x = a b = f (T , p )
x A ⋅ xB
c d
pC pD
⋅
p p
dla reakcji Kp = 0 0 = f (T ) p = 1 atm
a b 0
p A pB
aA + bB cC + dD ⋅
p p ciśnienia parcjalne
0 0
c d
cC cD
⋅
c c
K c = 0 a 0 b = f (T ) c0 = 1 mol ⋅ dm −3
c A cB
⋅
c c
0 0 stężenia
7. Zależności pomiędzy stałymi
− ∑ν i
p
K x ( T , p ) = K p (T )
p
0
− ∑ν i
p
K x ( T , p ) = K c (T )
c RT
0
− ∑ νi = c+d −a−b
Zauważmy, że
− ∑ νi = 0
K x (T , p ) = K p (T ) = K c (T )
8. Wartość K
T=const N 2 ( g ) + 3 H 2 ( g ) ↔ 2 NH 3( g ) + 92 kJ
Stężenia 2
Doświadczenie
[ NH ] Stężenia K
Kc = początkowe
3 równowagowe
I [ N=21.000 M2 ]3
[N ]2 0
][ H [N2] = 0.921 M
[H2]0 = 1.000 M [H2] = 0.763 M = 6.02·10-2
[NH3]0 = 0 M [NH3] = 0.157 M
II [N2]0 = 0 M [N2] = 0.399 M
[H2]0 = 0 M [H2] = 1.197 M = 6.02·10-2
[NH3]0 = 1.000 M [NH3] = 0.203 M
III [N2]0 = 2.000 M [N2] = 2.59 M
[H2]0 = 1.000 M [H2] = 2.77 M = 6.02·10-2
[NH3]0 = 3.000 M [NH3] = 1.82 M
9. Wartość K
K>>1 reakcja zachodzi w praktyce w
jedną stronę – produktów
K<<1 czyli K →0 reakcja praktycznie
nie zachodzi
10. Czynniki wpływające na wartość K
Temperatura
Ciśnienie (tylko Kx)
Zapis równania stechiometrycznego
11. Czynniki wpływające na wartość K
Temperatura
∆G o
∆G°= - RT ln(K) ln ( K ) = −
RT
∆G o = ∆H o − T∆S o
∆H o ∆S o
ln ( K ) = − +
RT R
egzo ∆H<0
K
∆S o ∆H o
−
endo ∆H>0 K =e R
e RT
temperatura
K jest funkcją temperatury!
12. Czynniki wpływające na wartość K
Zapis równania stechiometrycznego
[ HI ]2
1) H2(g) + I2(g)↔ 2HI(g) K1 =
[ H 2 ][ I 2 ]
[ HI ]
2) ½H2(g) + ½I2(g)↔ HI(g) K2 = 1 1 K 2 = K1
[H 2 ] [I2 ]
2 2
[ HI ]4
K3 = K 3 = K12
3) 2H2(g) + 2I2(g)↔ 4HI(g) [ H 2 ]2 [ I 2 ]2
[ H 2 ][ I 2 ]
K4 = K 4 = K1−1
4) 2HI(g) ↔ H2(g) + I2(g) [ HI ]2
13. Czynniki wpływające na wartość K
Zapis równania stechiometrycznego reakcji
2P(g) + 3Cl2(g) ↔ 2PCl3(g) x1 K1
PCl3(g) + Cl2(g) ↔ PCl5(g) x2 K2
2P(g) + 5Cl2(g) ↔ 2PCl5(g) K3
K3 = K1K22
14. Stała równowagi reakcji
heterogenicznych
CaCO3(s) ↔ CaO(s) + CO2(g)
K = [CO2]
13_1579
The position of a
heterogeneous
equilibrium does not
depend on the amounts
of pure solids or liquids CaCO3 CaO CaCO3 CaO
present.
15. Stała równowagi reakcji
heterogenicznych
Przykłady
Stężenia reagentów w czystych fazach
skondensowanych są stałe.
H2O(c)↔ H2O(g) K c = [ H 2O( g ) ] K p = pH 2O( g )
[ Ni(CO) 4 ] pNi ( CO )4
Ni(s) + 4CO(g) ↔ Ni(CO)4(g) Kc = Kp =
[CO]4 4
pCO
AgCl(s) ↔ Ag +
(r) + Cl (r)
- K c = [ Ag r+ ][Clr− ]
[ H 3Or+ ][Clr− ]
Kc =
HCl(r) + H2O(c)↔ H3O+(r)+ Cl-(r) [ HClr ]2
16. Sposoby wyznaczania K
Pomiar stężeń równowagowych
Pomiar temperaturowej zależności
ciepeł właściwych
Pomiar siły elektromotorycznej ogniw
17. Prawo działania mas
Synteza wiadomości
1. Równowaga ma charakter dynamiczny
2. Wartość K ∝ T, p
3. Wartość K ∝ zapisu równania stechiometrycznego
4. W stanie równowagi występują wszystkie reagenty
5. Jeżeli K>>1 ⇒ w stanie równowagi dominują produkty
6. Jeżeli znamy wartość K i stężenia aktualne to można
określić :
- czy układ jest w stanie równowagi
- w którą stronę biegnie reakcja
18. Równoważnik reakcji
c d
C D
aA + bB → cC + dD ⇒ Q = 0
a
0
b
A B 0 0
A0, B0, C0, D0 - stężenia początkowe
pozwala przewidzieć, w którą stronę pobiegnie reakcja
20. Równoważnik reakcji
Przewidywanie kierunku przebiegu reakcji
Q
K K Q K
Q
reakcja biegnie w reakcja w stanie reakcja biegnie w
stronę produktów rónowagi stronę substratów
21. Obliczenia równowagowe
Zastosowanie
1. Przewidywanie kierunku przebiegu reakcji
2. Obliczanie stopnia przereagowania
3. Obliczanie stężeń równowagowych
4. Zwiększanie wydajności reakcji
22. Obliczenia równowagowe
Algorytm
1. Zapisz równanie stechiometryczne
2. Zapisz wyrażenie na K
3. Oblicz Q
4. Określ kierunek przebiegu reakcji
5. Zbilansuj stężenia w tabeli
6. Podstaw stężenia do wyr ażenia na K
7. Rozwiąż równanie
8. Oblicz stężenia równowagowe
9. Sprawdź wartość K podstawiając obliczone stężenia
23. Obliczanie równowagowego
stopnia przemiany (x)
Przykład
CO(g) + H2O(g) ⇔ CO2(g) + H2(g)
T=700 K
K=5.10 [CO2 ][ H 2 ]
V=1.0 dm3 K= = 5.1
[CO][ H 2O ]
n = 1.0 mol każdego reagenta
Q =1< K
C=1 mol/dm3
CO H2O CO2 H2
n [mol] 1 1 1 1
co [mol/dm3] 1 1 1 1
zmiana -x -x +x +x
– stopień przemiany
cr [mol/dm3] 1-x 1-x 1+x 1+x
25. Reguła przekory
Le Châtelier
Jeżeli do układu w stanie równowagi wprowadzona
jest zmiana, położenie równowagi przesuwa się w
kierunku przeciwdziałającym tej zmianie.
27. Czynniki wpływające na położenie
równowagi
Zmiany stężenia (ciśnienia gazów)
Następująca reakcja jest w stanie równowagi w 450oC (Kc=49)
H 2(g) + I 2(g) ↔ 2 HI ( g )
Kc =
[ HI ]2 = 49
[ H 2 ][ I 2 ]
Jeżeli do układu w stanie równowagi dodajemy H2 ⇒
Q<Kc ⇒ reakcja biegnie w →
Jeżeli do układu w stanie równowagi ujmujemy H2 ⇒
Q>Kc ⇒ reakcja biegnie w ←
27
28. Czynniki wpływające na położenie
równowagi
Zmiana objętości (i ciśnienia dla gazów)
2 NO2 ( g ) ↔ N 2O4 ( g )
Kc =
[ N 2O 4 ]
[ NO2 ] 2
Jeżeli w stanie równowagi V ↓ (p ↑) ⇒
Q<Kc ⇒ reakcja biegnie w →
Jeżeli w stanie równowagi V ↑ (p ↓) ⇒
Q>Kc ⇒ reakcja biegnie w ←
28
29. Czynniki wpływające na położenie
równowagi
Zmiany temperatury
Następująca reakcja jest w stanie równowagi
2 SO2( g ) + O2( g ) ↔ 2 SO3( g ) + 198 kJ
Jeżeli w stanie równowagi T ↓ ⇒ reakcja biegnie w →
Jeżeli w stanie równowagi T ↑ ⇒ reakcja biegnie w ←
29
30. Czynniki wpływające na położenie
równowagi
Zmiany temperatury
∆S ∆H
K
egzo ∆H<0
K = f (T ) ⇒ ln( K ) = − endo ∆H>0
R RT temperatura
typ reakcji efekt temperatura kierunek
cieplny przebiegu
reakcji
egzotermiczne ∆H<O ↓ →
↑ ←
endotermiczne ∆H>O ↓ ←
↑ →
31. Czynniki wpływające na położenie
równowagi
Przykład
N 2O 4 ( g ) ↔ 2NO2 ( g ) ∆H = 58kJ
Kc =
[ NO2 ] 2
[ N 2O 4 ]
(a) stan początkowy
(b) równowaga
(c) wzrost T,
wzrost V,
obniżenie p
32. Proces Habera-Boscha
Przemysłowe otrzymywanie amoniaku
N 2 ( g ) + 3 H 2 ( g ) ← & metal oxides→ 2 NH3( g ) ∆ H o = − 92.22 kJ
Fe
N from liquid air
roczna światowa
2( g ) H 2( g ) fromml ton gas
140 coal
produkcja
run rxn. T = 450o C & P = 20075% H , 25% N
reagenty to 1000 atm 2 2
ciśnienie 150 atm
temperatura 650 - 720 K
katalizaor Fe
inne (chemiczny,
konwersja - 98% (15% na cykl) papierowy, itd..) 8%
nylon 7%
kwas azotowy 5%
nawozy sztuczne 80%
32
33. Proces Habera-Boscha
Zwiększanie wydajności
N 2( g ) + 3 H 2( g ) ← & oxides→ 2 NH3( g )
Fe metal
Co wiemy?
∆ G = -32.90 kJ/mol
∆ H = -92.22 kJ/mol
∆ S = -197 J/mol/K
Jednak
• Reakcja jest wolna jeżeli T jest mała
• Jednak jeżeli T↑ to wydajność reakcji spada
33
34. Czynniki wpływające na
położenie równowagi
N 2( g ) + 3 H 2( g ) ↔ 2 NH3( g ) + 92 kJ
a. Dodatek H2
b. Dodatek N2 Reaktor przepływowy
c. Usuwanie NH3
d. Wzrost ciśnienia (przez zmniejszanie objętości)
e. Odprowadzanie ciepła
34
36. Czynniki wpływające na
położenie równowagi
Przykład
Given the reaction below at equilibrium in a closed container at
500oC. How would the equilibrium be influenced by the
following?
N 2 ( g ) + 3 H 2 ( g ) ↔ 2 NH3( g ) + 92 kJ
a. Increasing the temperatu re ← left
b. Decreasing the temperatu re → right
c. Increasing the pressure by decreasing the volume → right
d. Introducin g some platinum catalyst no effect
e. Forcing more H 2 into the system → right
f. Removing some NH3 from the system → right
36
37. Uses of the Equilibrium
Constant, Kc
Example: The equilibrium constant, Kc, is 3.00 for
the following reaction at a given temperature. If
1.00 mole of SO2 and 1.00 mole of NO2 are put into
an evacuated 2.00-liter container and allowed to
reach equilibrium, what will be the concentration of
each compound at equilibrium?
SO2(g) + NO2(g) ↔ SO3(g) + NO(g)
37
38. Uses of the Equilibrium
Constant, Kc
SO2(g) + NO2(g) ↔ SO3(g) + NO(g)
Initial 0.500 M 0.500 M 0 0
38
39. Uses of the Equilibrium
Constant, Kc
SO2(g) + NO2(g) ↔ SO3(g) + NO(g)
Initial 0.500 M 0.500 M 0 0
Change -X M -X M +XM +XM
39
40. Uses of the Equilibrium
Constant, Kc
SO2(g) + NO2(g) ↔ SO3(g) + NO(g)
Initial 0.500 M 0.500 M 0 0
Change -X M -X M +XM +XM
Equilibrium ( 0.500 − X) M ( 0.500 − X) M XM XM
40
41. Uses of the Equilibrium
Constant, Kc
SO2(g) + NO2(g) ↔ SO3(g) + NO(g)
Initial 0.500 M 0.500 M 0 0
Change -X M -X M +XM +XM
Equilibrium ( 0.500 − X) M ( 0.500 − X) M XM XM
Kc =
[ SO3 ] [ NO] = 3.00 = ( X )( X )
[ SO2 ][ NO2 ] ( 0.500 − X)( 0.500 − X)
equation is a perfect square, ∴ take of both sides
41
42. Uses of the Equilibrium
Constant, Kc
SO2(g) + NO 2(g) ↔ SO3(g) + NO(g)
Initial 0.500 M 0.500 M 0 0
Change -X M -X M +XM +XM
Equilibrium ( 0.500 − X) M ( 0.500 − X) M XM XM
Kc =
[ SO3 ][ NO] = 3.00 = ( X )( X )
[ SO2 ][ NO2 ] ( 0.500 − X)( 0.500 − X)
equation is a perfect square, ∴ take of both sides
X
1.73 = ; 0.865 - 1.73 X = X ; 2.73 X = 0.865
0.500 − X
X = 0.316 M = [ SO3 ] = [ NO]
( 0.500 − X ) M = 0.184 M = [ SO2 ] = [ NO2 ] 42