Thong so ky thuat dan lanh fxmq + lo mo tran
1. 248
Notes) 1. Location of MANUFACTURE'S LABEL: 4. Space for Service Works
Control box surface According to any one of below 1)~3), secure a space
2. Mount the air filter at the suction side. for service works, such as, checking and maintenance
Select its colorimethod (gravity method) of control box and drain pumps, etc.
Dimensions
50% or more. 1) One inspection hatch (450 × 450) on the control box
3. Do not locate things should not be wet side and a space of 300mm or more under the unit.
16-φ 4.7 hole 27 631 under the indoor unit. (Fig. A)
10
(All around) (Suspention bolt position) Dews may drop when humidity reaches 2) One inspection hatch (450 × 450) on the control box
8
9 over 80%, or a drain gets stuck, or air side and 2 (two) inspection hatches under the unit.
filters are not clean. (Arrow View B-1)
3) 3 (three) inspection hatches under the unit and the
FXMQ20P / 25P / 32PVE
10-8 × 12 oblong hole control box. (Arrow View B-2)
3. Dimensions
(All around) CASE 1) Inspection hatch 1
355
Air Air inlet 210 (450mm × 450mm)
Control box
550
outlet
4 × 65=260
Control box
6 × 65=390
200
or less
300
or more
245
215
150
588 (Suspention bolt position)
Inspection hatch Ceiling Unit base
22-φ 4.7 hole Air Air
60
200
59
2 × 150=300 49
or less
outlet inlet
165
(All around) Fig. A
310 Inspection hatch 1
CASE 2), 3) (450mm × 450mm)
450 or more
335
Control box
(Service space)
Control box
Inspection hatch 3
View (SAME AS THE INDOOR
20
UNIT SIZE +300 OR MORE)
700 or more (From the Air outlet)
200
or more
Control box
or less
(Service space)
Inspection hatch 450 or more
B
850
Ceiling
550
or more
or more
Inspection hatch
167 700 700
Inspection hatch 2 or more or more
12 (SAME AS THE INDOOR View B-1 View B-2
UNIT SIZE OR MORE)
3 1 2 5 Air inlet 300 or less 288
Adjustable
6
(467 or less)
(Note. 2) 12 Drain hose (Accessory) O. D. φ 32 (Outlet)
Air outlet
Socket (For maintenance)
700 or less
11 VP25 (O. D. φ 32, I. D. φ 25)
10 Hook For M10
9 Air suction flange
277
247
150
300
232
212
8 Air discharge flange
150
144
80
Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark.
7 Power supply connection
169 12-8 × 12 oblong hole
40
11 3 × 150=450 6 Interunit wiring connection
7 4 (All around)
290 28 5 Control box (Inside)
700 475 4 Ground terminal (Terminal in Control box) M4
(Note. 4)
3 × 65=195
2 × 65=130
300 or more
500 3 Drain pipe connection VP25 (O. D. φ 32, I. D. φ 25)
2500 or more
(A case without
the ceiling)
2 Gas pipe connection φ 12.7 flale connection
Ceiling (From the Air inlet) 1 Liquid pipe connection φ 6.4 flale connection
Floor surface
ITEM PART NAME REMARK
3D062541A
Unit (mm)
ED34-862
FXMQ-P
2. Notes) 1. Location of MANUFACTURE'S LABEL: 4. Space for Service Works
FXMQ-P
ED34-862
Control box surface According to any one of below 1)~3), secure a space
2. Mount the air filter at the suction side. for service works, such as, checking and maintenance
Select its colorimethod (gravity method) of control box and drain pumps, etc.
FXMQ40PVE
27 631
10 50% or more. 1) One inspection hatch (450 × 450) on the control box
20-φ 4.7 hole (Suspention bolt position)
3. Do not locate things should not be wet side and a space of 300mm or more under the unit.
8 (All around) 9
under the indoor unit. (Fig. A)
Dews may drop when humidity reaches 2) One inspection hatch (450 × 450) on the control box
over 80%, or a drain gets stuck, or air side and 2 (two) inspection hatches under the unit.
filters are not clean. (Arrow View B-1)
3) 3 (three) inspection hatches under the unit and the
12-8 × 12 oblong hole control box. (Arrow View B-2)
505
(All around) Inspection hatch 1
CASE 1)
700
6 × 65=390
Air Air inlet 285 (450mm × 450mm)
8 × 65=520
Control box Control box
outlet
200
or less
300
or more
738 (Suspention bolt position)
245
215
150
Inspection hatch Ceiling Unit base
26-φ 4.7 hole Air Air
59
60
200
3 × 150=450 49
or less
outlet
165
(All around) inlet
Fig. A
460 Inspection hatch 1
CASE 2), 3) (450mm × 450mm)
450 or more
485 Control box
(Service space)
Control box
Inspection hatch 3
View (SAME AS THE INDOOR
20
(From the Air outlet) UNIT SIZE +300 OR MORE)
700 or more
or more
200
Control box
or less
(Service space)
Inspection hatch 450 or more
B
Ceiling
1000
700
or more
or more
Inspection hatch
167 700 700
Inspection hatch 2 or more or more
12 (SAME AS THE INDOOR
View B-1 View B-2
UNIT SIZE OR MORE)
3 1 2 5 Air inlet 300 or less 363
Adjustable
6 12 Drain hose (Accessory) O. D. φ 32 (Outlet)
(467 or less)
(Note. 2)
Air outlet 11 Socket (For maintenance) VP25 (O. D. φ 32, I. D. φ 25)
700 or less
10 Hook For M10
9 Air suction flange
277
247
150
300
Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark.
8 Air discharge flange
232
212
150
144
80
7 Power supply connection
169 14-8 × 12 oblong hole 6 Interunit wiring connection
40
11 7 4 (All around) 4 × 150=600 5 Control box (Inside)
290 28
4 Ground terminal (Terminal in Control box) M4
700
(Note. 4)
625
3 × 65=195
2 × 65=130
3 Drain pipe connection
300 or more
VP25 (O. D. φ 32, I. D. φ 25)
2500 or more
650 2 Gas pipe connection φ 12.7 flale connection
(A case without
the ceiling)
1 Liquid pipe connection φ 6.4 flale connection
Ceiling (From the Air inlet)
Floor surface ITEM PART NAME REMARK
3D060160E
Unit (mm)
249
Dimensions
7