SlideShare a Scribd company logo
1 of 19
Download to read offline
KUMPULAN TABEL MIL-STD-105E

Ir. Budi Nurtama, M.Agr.

2008
Program Studi Supervisor Jaminan Mutu Pangan
PROGRAM DIPLOMA
Institut Pertanian Bogor
Tables for MIL-STD-105E *)

Page

Table I. Sample-Size Code Letters.

1

Table II-A. Single Sampling Plans for Normal Inspection (Master Table).

2

Table II-B. Single Sampling Plans for Tightened Inspection (Master Table).

3

Table II-C. Single Sampling Plans for Reduced Inspection (Master Table).

4

Table III-A. Double Sampling Plans for Normal Inspection (Master Table).

5

Table III-B. Double Sampling Plans for Tightened Inspection (Master Table).

6

Table III-C. Double Sampling Plans for Reduced Inspection (Master Table).

7

Table IV-A. Multiple Sampling Plans for Normal Inspection (Master Table).

8

Table IV-A.(continued)

9

Table IV-B. Multiple Sampling Plans for Tightened Inspection (Master Table).

10

Table IV-B.(continued).

11

Table IV-C. Multiple Sampling Plans for Reduced Inspection (Master Table).

12

Table IV-C.(continued).

13

Table V-A. Average Outgoing Quality Limit Factors for Normal Inspection (Single Sampling).

14

Table V-A. Average Outgoing Quality Limit Factors for Tightened Inspection (Single Sampling).

15

Table VIII. Limit Numbers for Reduced Inspection.

16

*) Farnum, Nicholas R. 1994. Modern Statistical Quality Control and Improvement. Wadsworth, Inc., California.
i
Tahapan Implementasi MIL-STD-105E
1. Tentukan AQL (Acceptable Quality Level) berdasarkan perjanjian produsen dan pelanggan.
2. Tetapkan modus dan tingkat inspeksi (jika tidak, gunakan Normal Inspection, Level II ).
3. Tentukan ukuran lot (lot size).
4. Gunakan tabel Sample Size Code Letters untuk memilih huruf kode yang sesuai.
5. Tetapkan tipe prosedur pengambilan sampel : single, double, atau multiple sampling.
6. Gunakan tabel yang berkaitan dengan prosedur pengambilan sampel terpilih (tahap 5) dan modus/tingkat inspeksi (tahap 2) untuk mendapatkan ukuran sampel
dan angka penerimaan (Ac) serta angka penolakan (Re). Dalam kasus dimana suatu rancangan tidak ada untuk ukuran lot dan AQL-nya, hati-hati mengikuti
tanda panah dalam tabel ke rancangan terdekat yang ada.
7. Mulailah gunakan rancangan tersebut dan catat penerimaan dan penolakan sehingga switching rule dapat diterapkan. Jika switching dilakukan, tentukan modus
dan tingkat dan ulangi tahap 4-6 untuk mendapatkan rancangan pengambilan sampel yang baru.

SWITCHING RULE for MIL-STD-105E
• Dari Normal ke Tightened Inspection : setelah 2 lot ditolak dari 2, 3, 4, atau 5 lot berurutan
• Dari Tightened ke Normal Inspection : setelah 5 lot berurutan diterima
• Dari Normal ke Reduced Inspection

: jika (i) 10 lot berurutan diterima, dan (ii) jumlah total nonconforming items dalam 10 lot tersebut tidak melebihi batas
pada Table VIII. Limit Numbers for Reduced Inspection., dan (iii) produksi stabil/mantap, dan (iv) disetujui oleh otoritas
yang bertanggungjawab.

• Dari Reduced ke Normal Inspection

: jika (i) suatu lot tunggal ditolak, atau (ii) suatu lot hanya sebagian dapat diterima (dhi. jumlah nonconforming items
diantara angka diterima dan ditolak), atau (iii) produksi menjadi tidak stabil, atau (iv) kondisi-kondisi lain yang
menjamin bahwa inspeksi Normal dapat dilakukan.
ii
Table I. Sample-Size Code Letters.

Special Inspection Levels

General Inspection Levels

Lot or batch size
S-1

S-2

S-3

S-4

I

II

III

2

to

8

A

A

A

A

A

A

B

9

to

15

A

A

A

A

A

B

C

16

to

25

A

A

B

B

B

C

D

26

to

50

A

B

B

C

C

D

E

51

to

90

B

B

C

C

C

E

F

91

to

150

B

B

C

D

D

F

G

151

to

280

B

C

D

E

E

G

H

281

to

500

B

C

D

E

F

H

J

501

to

1,200

C

C

E

F

G

J

K

1,201

to

3,200

C

D

E

G

H

K

L

3,201

to

10,000

C

D

F

G

J

L

M

10,001

to

35,000

C

D

F

H

K

M

N

35,001

to

150,000

D

E

G

J

L

N

P

150,001

to

500,000

D

E

G

J

M

P

Q

500,001

and

over

D

E

H

K

N

Q

R

1
Table II - A. Single Sampling Plans for Normal Inspection (Master Table).
Acceptable Quality Levels (normal inspection)
Sample
size Sample 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
size
code
letter
Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A

2

B

3

C

5

D

8

E

13

F

20

G

32

H

50

J

80

K

125

L

200

M

315

N

500

P

800

Q

1250

R

2000

0 1

1 2

2 3

3 4

5 6

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22 30 31 44 45

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22 30 31 44 45

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22 30 31 44 45

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22 30 31 44 45

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

2 3

3 4

5 6

7 8 10 11 14 15 21 22

0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1

1 2

= Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection.

Ac = Acceptance number.

= Use first sampling plan above arrow.

7 8 10 11 14 15 21 22 30 31

Re = Rejection number.

2
Table II - B. Single Sampling Plans for Tightened Inspection (Master Table).
Acceptable Quality Levels (tightened inspection)
Sample
size Sample 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
size
code
letter
Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A

2

B

3

C

5

D

8

E

13

F

20

G

32

H

50

J

80

K

125

L

200

M

315

N

500

P

800

Q

1250

R

2000

S

3150

1 2

2 3

3 4

5 6

1 2

2 3

3 4

5 6

8 9 12 13 18 19 27 28 41 42

1 2

2 3

3 4

5 6

8 9 12 13 18 19 27 28 41 42

1 2

2 3

3 4

5 6

8 9 12 13 18 19 27 28 41 42

1 2

2 3

3 4

5 6

8 9 12 13 18 19 27 28 41 42

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

2 3

3 4

5 6

8 9 12 13 18 19

0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1

1 2

8 9 12 13 18 19 27 28

1 2

= Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection.

Ac = Acceptance number.

= Use first sampling plan above arrow.

Re = Rejection number.

3
Table II - C. Single Sampling Plans for Reduced Inspection (Master Table).
Acceptable Quality Levels (reduced inspection)
Sample
size Sample 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
size
code
letter
Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A

2

B

2

C

2

D

3

E

5

F

8

G

13

H

20

J

32

K

50

L

80

M

125

N

200

P

315

Q

500

R

800

0 1

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22 30 31

0 2

1 3

2 4

3 5

5 6

7 8 10 11 14 15 21 22 30 31

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13 14 17 21 24

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13 14 17 21 24

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13 14 17 21 24

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1

0 2

= Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection.

Ac = Acceptance number.

= Use first sampling plan above arrow.
= If the acceptance number has been exceeded, but the rejection number has not been reached; accept the lot, but reinstate normal inspection.

Re = Rejection number.

4
Table III - A. Double Sampling Plans for Normal Inspection (Master Table).
Acceptable Quality Levels (normal inspection)
Sample
Cumula
size
Sample tive
Sample
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A
B

First
Second

2
2

2
4

C

First
Second

3
3

3
6

D

First
Second

5
5

5
10

E

First
Second

8
8

8
16

F

First
Second

13
13

13
26

G

First
Second

20
20

20
40

H

First
Second

32
32

32
64

J

First
Second

50
50

50
100

K

First
Second

80
80

80
160

L

First
Second

125
125

125
250

M

First
Second

200
200

200
400

N

First
Second

315
315

315
630

P

First
Second

500
500

500
1000

Q

First
Second

800
800

800
1600

R

First
1250
Second 1250

1250
2500

0 2
1 2

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7 5 9 7 11 11 16
8 9 12 13 18 19 26 27

0 2
1 2
0 2
1 2

0 3
3 4

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

3 7
8 9

5 9 7 11 11 16 17 22 25 31
12 13 18 19 26 27 37 38 56 57

5 9 7 11 11 16 17 22 25 31
12 13 18 19 26 27 37 38 56 57

5 9 7 11 11 16 17 22 25 31
12 13 18 19 26 27 37 38 56 57

5 9 7 11 11 16 17 22 25 31
12 13 18 19 26 27 37 38 56 57

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

= Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection.
= Use first sampling plan above arrow.
= Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).

Ac = Acceptance number.
Re = Rejection number.

5
Table III - B. Double Sampling Plans for Tightened Inspection (Master Table).
Acceptable Quality Levels (normal inspection)
Sample
Cumula
size
Sample tive
Sample
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A
B

First
Second

2
2

2
4

C

First
Second

3
3

3
6

D

First
Second

5
5

5
10

E

First
Second

8
8

8
16

F

First
Second

13
13

13
26

G

First
Second

20
20

20
40

H

First
Second

32
32

32
64

J

First
Second

50
50

50
100

K

First
Second

80
80

80
160

L

First
Second

125
125

125
250

M

First
Second

200
200

200
400

N

First
Second

315
315

315
630

P

First
Second

500
500

500
1000

Q

First
Second

800
800

800
1600

R

First
1250
Second 1250

1250
2500

S

First
2000
Second 2000

2000
4000

0 2
1 2

1 4
4 5

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5 3 7 6 10 9 14
6 7 11 12 15 16 23 24

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5 3 7 6 10 9 14
6 7 11 12 15 16 23 24

0 2
1 2
0 2
1 2

0 3
3 4

0 3
3 4

1 4
4 5

2 5
6 7

0 3
3 4

1 4
4 5

2 5
6 7

2 5
6 7

3 7 6 10 9 14 15 20 23 29
11 12 15 16 23 24 34 35 52 53

3 7 6 10 9 14 15 20 23 29
11 12 15 16 23 24 34 35 52 53

3 7 6 10 9 14 15 20 23 29
11 12 15 16 23 24 34 35 52 53

3 7 6 10 9 14 15 20 23 29
11 12 15 16 23 24 34 35 52 53

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

0 2
1 2

= Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection.
= Use first sampling plan above arrow.
= Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).

Ac = Acceptance number.
Re = Rejection number.

6
Table III - C. Double Sampling Plans for Reduced Inspection (Master Table).
Acceptable Quality Levels (reduced inspection)
Sample
Cumula
size
Sample tive
Sample
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A
B
C
D

First
Second

2
2

2
4

E

First
Second

3
3

3
6

F

First
Second

5
5

5
10

G

First
Second

8
8

8
16

H

First
Second

13
13

13
26

J

First
Second

20
20

20
40

K

First
Second

32
32

32
64

L

First
Second

50
50

50
100

M

First
Second

80
80

80
160

N

First
Second

125
125

125
250

P

First
Second

200
200

200
400

Q

First
Second

315
315

315
630

R

First
Second

500
500

500
1000

=
=
Ac =
Re =
=
=

0 2
0 2

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10 7 12 11 17
8 12 12 16 18 22 26 30

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2
0 2
0 2

0 3
0 4

3 8 5 10 7 12 11 17
8 12 12 16 18 22 26 30

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection.
Use first sampling plan above arrow.
Acceptance number.
Rejection number.
Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).
If, after the second sample, the acceptance number has been exceeded, but the rejection number has not been reached, accept the lot, but reinstate normal inspection.

7
Table IV - A. Multiple Sampling Plans for Normal Inspection (Master Table).
Acceptable Quality Levels (normal inspection)
Sample
Cumula
size
Sample tive
Sample
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A
B
C
D

E

F

G

H

J

First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh

2
2
2
2
2
2
2
3
3
3
3
3
3
3
5
5
5
5
5
5
5
8
8
8
8
8
8
8
13
13
13
13
13
13
13
20
20
20
20
20
20
20

2
4
6
8
10
12
14
3
6
9
12
15
18
21
5
10
15
20
25
30
35
8
16
24
32
40
48
56
13
26
39
52
65
78
91
20
40
60
80
100
120
140

#
#
0
0
1
1
2

2
2
2
3
3
3
3

#
#
0
0
1
1
2
#
0
0
1
2
3
4

2
2
2
3
3
3
3
2
3
3
4
4
5
5

#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7

#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6
#
1
2
3
5
7
9

# 2
# 2
0 2
0 3
1 3
1 3
2 3
2 # 2
2 0 3
2 0 3
3 1 4
3 2 4
3 3 5
3 4 5
2 # 3
3 0 3
3 1 4
4 2 5
4 3 6
5 4 6
5 6 7
3 # 4
3 1 5
4 2 6
5 3 7
6 5 8
6 7 9
7 9 10
4
0 4
5
1 6
6
3 8
7
5 10
8
7 11
9 10 12
10 13 14

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19

++
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26

++
++
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

++
++
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

++
++
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

= Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection.
= Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).
Ac = Acceptance number.
++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available).
# = Acceptance not permitted at this sample size.

++
++
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

++
++
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

++
++
2 9
7 14
13 19
19 25
25 29
31 33
37 38
4 12
11 19
19 27
27 34
36 40
45 47
53 54

++
++
4 12
11 19
19 27
27 34
36 40
45 47
53 54
6 16
17 27
29 39
40 49
53 58
65 68
77 78

++
++
6 16
17 27
29 39
40 49
53 58
65 68
77 78

++
++

++

= Use first sampling plan above arrow.
Re = Rejection number.

8
Table IV - A. (continued).

Acceptable Quality Levels (normal inspection
Sample
Cumula
size
Sample tive
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
Sample
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
K

L

M

N

P

Q

R

First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh

32
32
32
32
32
32
32
50
50
50
50
50
50
50
80
80
80
80
80
80
80
125
125
125
125
125
125
125
200
200
200
200
200
200
200
315
315
315
315
315
315
315
500
500
500
500
500
500
500

32
64
96
128
160
192
224
50
100
150
200
250
300
350
80
160
240
320
400
480
560
125
250
375
500
625
750
875
200
400
600
800
1000
1200
1400
315
630
945
1260
1575
1890
2205
500
1000
1500
2000
2500
3000
3500

#
#
0
0
1
1
2

2
2
2
3
3
3
3

#
#
0
0
1
1
2
#
0
0
1
2
3
4

2
2
2
3
3
3
3
2
3
3
4
4
5
5

#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7

#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6
#
1
2
3
5
7
9

# 2
# 2
0 2
0 3
1 3
1 3
2 3
2 # 2
2 0 3
2 0 3
3 1 4
3 2 4
3 3 5
3 4 5
2 # 3
3 0 3
3 1 4
4 2 5
4 3 6
5 4 6
5 6 7
3 # 4
3 1 5
4 2 6
5 3 7
6 5 8
6 7 9
7 9 10
4
0 4
5
1 6
6
3 8
7
5 10
8
7 11
9 10 12
10 13 14

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26

# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

0
1
3
5
7
10
13
0
3
6
8
11
14
18
1
4
8
12
17
21
25
2
7
13
19
25
31
37

4
6
8
10
11
12
14
5
8
10
13
15
17
19
7
10
13
17
20
23
26
9
14
19
25
29
33
38

0
3
6
8
11
14
18
1
4
8
12
17
21
25
2
7
13
19
25
31
37

5
8
10
13
15
17
19
7
10
13
17
20
23
26
9
14
19
25
29
33
38

1
4
8
12
17
21
25
2
7
13
19
25
31
37

7
10
13
17
20
23
26
9
14
19
25
29
33
38

2
7
13
19
25
31
37

9
14
19
25
29
33
38

= Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 1
= Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).
Ac = Acceptance number.
++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available).
# = Acceptance not permitte
Table IV - B. Multiple Sampling Plans for Tightened Inspection (Master Table).
Acceptable Quality Levels (tightened inspection)
Sample
Cumula
size
Sample tive
Sample
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A
B
C
D

E

F

G

H

J

First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh

2
2
2
2
2
2
2
3
3
3
3
3
3
3
5
5
5
5
5
5
5
8
8
8
8
8
8
8
13
13
13
13
13
13
13
20
20
20
20
20
20
20

2
4
6
8
10
12
14
3
6
9
12
15
18
21
5
10
15
20
25
30
35
8
16
24
32
40
48
56
13
26
39
52
65
78
91
20
40
60
80
100
120
140

#
#
0
0
1
1
2

2
2
2
3
3
3
3

#
#
0
0
1
1
2
#
0
0
1
2
3
4

2
2
2
3
3
3
3
2
3
3
4
4
5
5

#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
4
4
5
6
6
7

#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6
#
1
2
3
5
7
9

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
4
4
5
6
6
7
4
5
6
7
8
9
10

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22

++
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

++
++
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

++
++
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

= Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection.
= Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).
Ac = Acceptance number.
++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available).
# = Acceptance not permitted at this sample size.

++
++
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

++
++
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

++
++
1 8
6 12
11 17
16 22
22 25
27 29
32 33
3 10
10 17
17 24
24 31
32 37
40 43
48 49

++
++
3 10
10 17
17 24
24 31
32 37
40 43
48 49
6 15
16 25
26 36
37 46
49 55
61 64
72 73

++
++
6 15
16 25
26 36
37 46
49 55
61 64
72 73

++
++

++

= Use first sampling plan above arrow.
Re = Rejection number.

10
Table IV - B. (continued).
Acceptable Quality Levels (tightened inspection)
Sample
Cumula
size
Sample tive
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
Sample
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
K

L

M

N

P

Q

R

S

First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh

32
32
32
32
32
32
32
50
50
50
50
50
50
50
80
80
80
80
80
80
80
125
125
125
125
125
125
125
200
200
200
200
200
200
200
315
315
315
315
315
315
315
500
500
500
500
500
500
500
800
800
800
800
800
800
800

32
64
96
128
160
192
224
50
100
150
200
250
300
350
80
160
240
320
400
480
560
125
250
375
500
625
750
875
200
400
600
800
1000
1200
1400
315
630
945
1260
1575
1890
2205
500
1000
1500
2000
2500
3000
3500
800
1600
2400
3200
4000
4800
5600

#
#
0
0
1
1
2
#
#
0
0
1
1
2

2
2
2
3
3
3
3

#
#
0
0
1
1
2
#
0
0
1
2
3
4

2
2
2
3
3
3
3
2
3
3
4
4
5
5

#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
4
4
5
6
6
7

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

0
2
4
6
9
12
14
0
3
7
10
14
18
21
1
6
11
16
22
27
32

4
7
9
11
12
14
15
6
9
12
15
17
20
22
8
12
17
22
25
29
33

0
3
7
10
14
18
21
1
6
11
16
22
27
32

6
9
12
15
17
20
22
8
12
17
22
25
29
33

1
6
11
16
22
27
32

8
12
17
22
25
29
33

2
2
2
3
3
3
3

11
Table IV - C. Multiple Sampling Plans for Reduced Inspection (Master Table).
Acceptable Quality Levels (reduced inspection)
Sample
Cumula
size
Sample tive
Sample
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A
B
C
D
E

++
++

++

F

First
Second
Third
Fourth
Fifth
Sixth
Seventh

2
2
2
2
2
2
2

2
4
6
8
10
12
14

G

First
Second
Third
Fourth
Fifth
Sixth
Seventh

3
3
3
3
3
3
3

3
6
9
12
15
18
21

H

First
Second
Third
Fourth
Fifth
Sixth
Seventh

5
5
5
5
5
5
5

5
10
15
20
25
30
35

J

First
Second
Third
Fourth
Fifth
Sixth
Seventh

8
8
8
8
8
8
8

8
16
24
32
40
48
56

K

First
Second
Third
Fourth
Fifth
Sixth
Seventh

13
13
13
13
13
13
13

13
26
39
52
65
78
91

++
++

++
++

#
#
0
0
0
0
1

2
2
2
3
3
3
3

#
#
0
0
0
1
1

2
3
3
4
4
5
5

#
#
0
0
1
1
2

3
3
4
5
6
6
7

#
0
0
1
2
3
4

3
4
5
6
7
7
8

# 4
0 5
1 6
2 7
3 8
4 9
6 10

#
#
0
0
0
0
1

2
2
2
3
3
3
3

#
#
0
0
0
1
1

2
3
3
4
4
5
5

#
#
0
0
1
1
2

3
3
4
5
6
6
7

#
0
0
1
2
3
4

3
4
5
6
7
7
8

# 4
0 5
1 6
2 7
3 8
4 9
6 10

#
#
0
0
0
0
1

2
2
2
3
3
3
3

#
#
0
0
0
1
1

2
3
3
4
4
5
5

#
#
0
0
1
1
2

3
3
4
5
6
6
7

#
0
0
1
2
3
4

3
4
5
6
7
7
8

# 4
0 5
1 6
2 7
3 8
4 9
6 10

#
#
0
0
0
0
1
#
#
0
0
0
0
1

2
2
2
3
3
3
3

2
2
2
3
3
3
3

#
#
0
0
0
1
1

2
3
3
4
4
5
5

#
#
0
0
1
1
2

3
3
4
5
6
6
7

#
0
0
1
2
3
4

#
#
0
0
0
1
1

2
3
3
4
4
5
5

#
#
0
0
1
1
2

3
3
4
5
6
6
7

#
0
0
1
2
3
4

3
4
5
6
7
7
8

# 4
0 5
1 6
2 7
3 8
4 9
6 10

#
1
2
3
5
7
9

#
1
2
3
5
7
9

#
1
2
3
5
7
9

3
4
5
6
7
7
8

++
++

# 4
0 5
1 6
2 7
3 8
4 9
6 10

#
1
2
3
5
7
9

#
1
2
3
5
7
9

++
++

++
++

++
++

++
++

++
++

++

4 0 5 0 6
6 1 7 3 9
8 3 9 6 12
10 5 12 8 15
11 7 13 11 17
12 10 15 14 20
14 13 17 18 22

4 0 5 0 6
6 1 7 3 9
8 3 9 6 12
10 5 12 8 15
11 7 13 11 17
12 10 15 14 20
14 13 17 18 22

4 0 5 0 6
6 1 7 3 9
8 3 9 6 12
10 5 12 8 15
11 7 13 11 17
12 10 15 14 20
14 13 17 18 22

4 0 5 0 6
6 1 7 3 9
8 3 9 6 12
10 5 12 8 15
11 7 13 11 17
12 10 15 14 20
14 13 17 18 22

4 0 5 0 6
6 1 7 3 9
8 3 9 6 12
10 5 12 8 15
11 7 13 11 17
12 10 15 14 20
14 13 17 18 22

= Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection.
= Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).
Ac = Acceptance number.
++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available).
# = Acceptance not permitted at this sample size.
= If, after the final sample, the acceptance number has been exceeded but the rejection number has not been reached, accept the lot but reinstate normal inspection.

= Use first sampling plan above arrow.
Re = Rejection number.

12
Table IV - C. (continued).
Acceptable Quality Levels (reduced inspection)
Sample
Cumula
size
Sample tive
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
Sample
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
L

M

N

P

Q

R

First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh

20
20
20
20
20
20
20
32
32
32
32
32
32
32
50
50
50
50
50
50
50
80
80
80
80
80
80
80
125
125
125
125
125
125
125
200
200
200
200
200
200
200

20
40
60
80
100
120
140
32
64
96
128
160
192
224
50
100
150
200
250
300
350
80
160
240
320
400
480
560
125
250
375
500
625
750
875
200
400
600
800
1000
1200
1400

#
#
0
0
0
0
1

2
2
2
3
3
3
3

#
#
0
0
0
0
1
#
#
0
0
0
1
1

2
2
2
3
3
3
3
2
3
3
4
4
5
5

#
#
0
0
0
0
1
#
#
0
0
0
1
1
#
#
0
0
1
1
2

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7

#
#
0
0
0
0
1
#
#
0
0
0
1
1
#
#
0
0
1
1
2
#
0
0
1
2
3
4

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7
3
4
5
6
7
7
8

#
#
0
0
0
0
1
#
#
0
0
0
1
1
#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7
3
4
5
6
7
7
8
4
5
6
7
8
9
10

#
#
0
0
0
0
1
#
#
0
0
0
1
1
#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6
#
1
2
3
5
7
9

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7
3
4
5
6
7
7
8
4
5
6
7
8
9
10
4
6
8
10
11
12
14

# 2
# 3
0 3
0 4
0 4
1 5
1 5
# 3
# 3
0 4
0 5
1 6
1 6
2 7
# 3
0 4
0 5
1 6
2 7
3 7
4 8
# 4
0 5
1 6
2 7
3 8
4 9
6 10
# 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17

# 3
# 3
0 4
0 5
1 6
1 6
2 7
# 3
0 4
0 5
1 6
2 7
3 7
4 8
# 4
0 5
1 6
2 7
3 8
4 9
6 10
# 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

# 3
0 4
0 5
1 6
2 7
3 7
4 8
# 4
0 5
1 6
2 7
3 8
4 9
6 10
# 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

# 4
0 5
1 6
2 7
3 8
4 9
6 10
# 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

#
1
2
3
5
7
9
0
1
3
5
7
10
13
0
3
6
8
11
14
18

4
6
8
10
11
12
14
5
7
9
12
13
15
17
6
9
12
15
17
20
22

0
1
3
5
7
10
13
0
3
6
8
11
14
18

5 0 6
7 3 9
9 6 12
12 8 15
13 11 17
15 14 20
17 18 22
6
9
12
15
17
20
22

= Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection.
= Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).
Ac = Acceptance number.
++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available).
# = Acceptance not permitted at this sample size.
= If, after the final sample, the acceptance number has been exceeded but the rejection number has not been reached, accept the lot but reinstate normal inspection.

= Use first sampling plan above arrow.
Re = Rejection number.

13
Table V-A. Average Outgoing Quality Limit Factors for Normal Inspection (Single Sampling) *
Code Sample
Letter size
A

H
J

80

K

125

65

100

150

250

400

650

1000

42

69

97

160

220

330

470

730

1100

28

46

65

110

150

220

310

490

720

1100

17

27

39

63

90

130

190

290

430

660

11

17

24

40

56

82

120

180

270

410

6.5

11

15

24

34

50

72

110

170

250

4.2

6.9

9.7

16

22

33

47

73

2.6

4.3

6.1

9.9

14

21

29

46

1.7

2.7

3.9

6.3

9.0

13

19

29

1.7

2.4

4.0

5.6

8.2

12

18

0.67

50

40

1.1

32

25

1.1

1.6

2.5

3.6

5.2

7.5

12

7.3

20

G

0.40

0.65

13

F

0.25

1.0

8

E

0.15

1.5

5

D

0.10

2.5

3

C

0.010 0.015 0.025 0.040 0.065

4.0

2

B

Acceptable Quality Level

L

1250

R

2000

4.6
2.8
1.8
1.2
0.74
0.46
0.29

800

Q

7.4

500

P

12

315

N

10

15

18

200

M

6.5

0.42

0.69

0.97

1.6

2.2

3.3

4.7

0.27

0.44

0.62

1.00

1.4

2.1

3.0

4.7

2.9

0.18
0.12
0.074

0.17

0.27

0.39

0.63

0.90

1.3

1.9

0.11

0.17

0.24

0.40

0.56

0.82

1.2

1.8

0.11

0.16

0.25

0.36

0.52

0.75

1.2

0.042 0.069 0.097

0.16

0.22

0.33

0.47

0.73

0.046
0.029

0.067

* Note: For the exact AOQL, the above volume must be multiplied by 1

Sample size
Lot or Batch size

14
Table V-B. Average Outgoing Quality Limit Factors for Tightened Inspection (Single Sampling) *
Code Sample
Letter size
A

H

50

J

80

K

125

1.0

1.5

2.5

4.0

6.5

40

65

100

150

250

400

650

1000

42

32

0.65

20

G

0.40

13

F

0.25

8

E

0.15

5

D

0.10

69

97

160

260

400

620

970

28

46

65

110

170

270

410

650

1100

17

27

39

63

100

160

250

390

610

11

3

C

0.010 0.015 0.025 0.040 0.065

10

15

25

17

24

40

64

99

160

240

380

11

15

24

40

61

95

150

240

62

2

B

Acceptable Quality Level

L

2000

S

3150

4.2

6.9

9.7

16

26

40

2.6

4.3

6.1

9.9

16

25

39

1.7

2.7

3.9

6.3

16

25

1.1

1.7

2.4

4.0

6.4

9.9

0.67

1.1

1.6

2.5

4.1

6.4

9.9

6.2

1.2
0.74
0.46
0.29

1250

R

6.5

1.8

800

Q

2.8

500

P

4.6

315

N

7.4

200

M

12

0.18

0.42

0.074

0.69

0.97

1.6

2.6

4.0

0.27

0.12

0.44

0.62

1.0

1.6

2.5
2.5

0.17

0.27

0.39

0.63

1.0

1.6

0.17

0.24

0.40

0.64

0.99

1.6

0.11

0.16

0.25

0.41

0.64

0.99

0.042 0.069 0.097

0.16

0.26

0.40

0.62

0.067

0.018

16

3.9

0.11

0.046
0.029

10

0.027

* Note: For the exact AOQL, the above volume must be multiplied by 1

Sample size
Lot or Batch size

15
Table VIII. Limit Numbers for Reduced Inspection.
Number of
sample units
from last 10
lots or batches

Acceptable Quality Level
0.010 0.015 0.025 0.040 0.065

0.10

0.15

0.25

0.40

0.65

1.0

1.5

2.5

4.0

6.5

10

15

25

40

65

100

150

250

400

650

1000

115
178
301

181
277

20 - 29
30 - 49
50 - 79

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
0

∙
0
0

0
0
2

0
1
3

2
3
7

4
7
14

8
13
25

14
22
40

22
36
63

40
63
110

68
105
181

80 - 129
130 - 199
200 - 319

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
0

∙
0
0

0
0
2

0
2
4

2
4
8

4
7
14

7
13
22

14
25
40

24
42
68

42
72
115

68
115
181

105
177
277

181
301
471

297
490

320 - 499
500 - 799
800 - 1249

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
0

∙
0
0

0
0
2

0
2
4

1
3
7

4
7
14

8
14
24

14
25
42

24
40
68

39
63
105

68
110
181

113
181

189

1250 - 1999
2000 - 3149
3150 - 4999

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
∙

∙
∙
0

∙
0
0

0
0
1

0
2
4

2
4
8

4
8
14

7
14
24

13
22
38

24
40
67

40
68
111

69
115
186

110
181

169

5000 - 7999
8000 - 12499
12500 - 19999

∙
∙
∙

∙
∙
0

∙
0
0

0
0
2

0
2
4

2
4
7

3
7
13

7
14
24

14
24
40

25
42
69

40
68
110

63
105
169

110
181

181

20000 - 31499
31500 - 49999
50000 & over

0
0
2

0
1
3

2
4
7

4
8
14

8
14
25

14
24
40

22
38
63

40
67
110

68
111
181

115
186
301

181

∙ Denotes that the number of sample units from the last ten lots or batches is not sufficient for reduced inspection for this AQL. In this instance more than ten lots or batches may be used for the calculation, provided that the lots or
batches used are the most recent ones in sequence, that they have all been on normal inspection, and that none has been rejected while on original inspection.

16

More Related Content

What's hot

P gge-03 (2) control de producto no conforme
P gge-03 (2) control de producto no conformeP gge-03 (2) control de producto no conforme
P gge-03 (2) control de producto no conformeDaniel Castillo
 
5 principios haccp caoca 583802
5 principios haccp caoca   5838025 principios haccp caoca   583802
5 principios haccp caoca 583802Jose Luis Medina
 
Iso2859 1 muestreo inspeccion
Iso2859 1 muestreo inspeccionIso2859 1 muestreo inspeccion
Iso2859 1 muestreo inspeccionGisela Nataly
 
Procedimiento para el contl del prod o serv
Procedimiento para el contl del prod o servProcedimiento para el contl del prod o serv
Procedimiento para el contl del prod o servturleziitho94
 
EIA para la instalación de una planta de conservas de pescado.pptx
EIA para la instalación de una planta de conservas de pescado.pptxEIA para la instalación de una planta de conservas de pescado.pptx
EIA para la instalación de una planta de conservas de pescado.pptxRonald Campaña
 
GUIA-PARA-LA-VALIDACION-DE-LOS-PROCESOS-DE-LIMPIEZA-EN-LA-FABRICACION-DE-PROD...
GUIA-PARA-LA-VALIDACION-DE-LOS-PROCESOS-DE-LIMPIEZA-EN-LA-FABRICACION-DE-PROD...GUIA-PARA-LA-VALIDACION-DE-LOS-PROCESOS-DE-LIMPIEZA-EN-LA-FABRICACION-DE-PROD...
GUIA-PARA-LA-VALIDACION-DE-LOS-PROCESOS-DE-LIMPIEZA-EN-LA-FABRICACION-DE-PROD...SARAHCRISTHEL
 
Calificación de Personal Técnico
Calificación de Personal TécnicoCalificación de Personal Técnico
Calificación de Personal TécnicoNombre Apellidos
 
P 03-01 acciones correctivas-preventivas
P 03-01 acciones correctivas-preventivasP 03-01 acciones correctivas-preventivas
P 03-01 acciones correctivas-preventivasLeandro Nicenboim
 
Western electric rules
Western electric rulesWestern electric rules
Western electric rulesLaura Garcia
 
Flujograma de cap boritex corregido (1)
Flujograma de cap boritex corregido (1)Flujograma de cap boritex corregido (1)
Flujograma de cap boritex corregido (1)Freddy Melo
 

What's hot (20)

Beneficios de las BPM
Beneficios de las BPMBeneficios de las BPM
Beneficios de las BPM
 
Autonomacion (2)
Autonomacion (2)Autonomacion (2)
Autonomacion (2)
 
P gge-03 (2) control de producto no conforme
P gge-03 (2) control de producto no conformeP gge-03 (2) control de producto no conforme
P gge-03 (2) control de producto no conforme
 
5 principios haccp caoca 583802
5 principios haccp caoca   5838025 principios haccp caoca   583802
5 principios haccp caoca 583802
 
Delhi in
Delhi inDelhi in
Delhi in
 
Ge mapa conceptual sgc
Ge mapa conceptual sgcGe mapa conceptual sgc
Ge mapa conceptual sgc
 
Iso2859 1 muestreo inspeccion
Iso2859 1 muestreo inspeccionIso2859 1 muestreo inspeccion
Iso2859 1 muestreo inspeccion
 
Procedimiento para el contl del prod o serv
Procedimiento para el contl del prod o servProcedimiento para el contl del prod o serv
Procedimiento para el contl del prod o serv
 
Balanza analitica kern acj acs (93)
Balanza analitica kern acj acs (93)Balanza analitica kern acj acs (93)
Balanza analitica kern acj acs (93)
 
EIA para la instalación de una planta de conservas de pescado.pptx
EIA para la instalación de una planta de conservas de pescado.pptxEIA para la instalación de una planta de conservas de pescado.pptx
EIA para la instalación de una planta de conservas de pescado.pptx
 
Manual de trazabilidad
Manual de trazabilidadManual de trazabilidad
Manual de trazabilidad
 
Aseguramiento y control de la calidad
Aseguramiento y control de la calidadAseguramiento y control de la calidad
Aseguramiento y control de la calidad
 
GUIA-PARA-LA-VALIDACION-DE-LOS-PROCESOS-DE-LIMPIEZA-EN-LA-FABRICACION-DE-PROD...
GUIA-PARA-LA-VALIDACION-DE-LOS-PROCESOS-DE-LIMPIEZA-EN-LA-FABRICACION-DE-PROD...GUIA-PARA-LA-VALIDACION-DE-LOS-PROCESOS-DE-LIMPIEZA-EN-LA-FABRICACION-DE-PROD...
GUIA-PARA-LA-VALIDACION-DE-LOS-PROCESOS-DE-LIMPIEZA-EN-LA-FABRICACION-DE-PROD...
 
No conformidad
No conformidadNo conformidad
No conformidad
 
Calificación de Personal Técnico
Calificación de Personal TécnicoCalificación de Personal Técnico
Calificación de Personal Técnico
 
Lista de chequeo bpm
Lista de chequeo bpmLista de chequeo bpm
Lista de chequeo bpm
 
Auditoria plan haccp
Auditoria plan haccpAuditoria plan haccp
Auditoria plan haccp
 
P 03-01 acciones correctivas-preventivas
P 03-01 acciones correctivas-preventivasP 03-01 acciones correctivas-preventivas
P 03-01 acciones correctivas-preventivas
 
Western electric rules
Western electric rulesWestern electric rules
Western electric rules
 
Flujograma de cap boritex corregido (1)
Flujograma de cap boritex corregido (1)Flujograma de cap boritex corregido (1)
Flujograma de cap boritex corregido (1)
 

Viewers also liked

Military standard 105E and 414
Military standard 105E and 414Military standard 105E and 414
Military standard 105E and 414ananya0122
 
Muestreo y Tabla Militar
Muestreo y Tabla MilitarMuestreo y Tabla Militar
Muestreo y Tabla MilitarPROYECTOCENAL
 
Recepción Técnica y Administrativa de Medicamentos.
Recepción Técnica y Administrativa de Medicamentos.Recepción Técnica y Administrativa de Medicamentos.
Recepción Técnica y Administrativa de Medicamentos.Alexander Rojas Patiño
 
Hospitality presentation nagelhout
Hospitality presentation nagelhoutHospitality presentation nagelhout
Hospitality presentation nagelhoutEd Nagelhout
 
Calidad empresarial, mil std-105 e
Calidad empresarial, mil std-105 eCalidad empresarial, mil std-105 e
Calidad empresarial, mil std-105 eJose Hereira
 
Aseguramiento Calidad Expo
Aseguramiento Calidad   ExpoAseguramiento Calidad   Expo
Aseguramiento Calidad ExpoGenaro Vivanco
 
Muestreo Aceptacion por atributos Generalidades
Muestreo Aceptacion por atributos GeneralidadesMuestreo Aceptacion por atributos Generalidades
Muestreo Aceptacion por atributos GeneralidadesLuis Dicovskiy
 
Muestreo en control de calidad
Muestreo en control de calidadMuestreo en control de calidad
Muestreo en control de calidadsorayac
 
Uso de la tabla mil std 105 d para definir planes de muestreo
Uso de la tabla mil std 105 d para definir planes de muestreoUso de la tabla mil std 105 d para definir planes de muestreo
Uso de la tabla mil std 105 d para definir planes de muestreoKevin Sosa Matos
 
Iso2859 1 muestreo inspeccion
Iso2859 1 muestreo inspeccionIso2859 1 muestreo inspeccion
Iso2859 1 muestreo inspeccionLorena Soria
 

Viewers also liked (20)

Military standard 105E and 414
Military standard 105E and 414Military standard 105E and 414
Military standard 105E and 414
 
Table mil std_105_e
Table mil std_105_eTable mil std_105_e
Table mil std_105_e
 
Quality Control Of Garment
Quality Control Of Garment Quality Control Of Garment
Quality Control Of Garment
 
Muestreo y Tabla Militar
Muestreo y Tabla MilitarMuestreo y Tabla Militar
Muestreo y Tabla Militar
 
Muestreo y tabla militar
Muestreo y tabla militar  Muestreo y tabla militar
Muestreo y tabla militar
 
norma-mil-std-105d
norma-mil-std-105dnorma-mil-std-105d
norma-mil-std-105d
 
8 planes de muestreo
8 planes de muestreo8 planes de muestreo
8 planes de muestreo
 
Clase ues bromato muestreo
Clase ues bromato muestreoClase ues bromato muestreo
Clase ues bromato muestreo
 
Recepción Técnica y Administrativa de Medicamentos.
Recepción Técnica y Administrativa de Medicamentos.Recepción Técnica y Administrativa de Medicamentos.
Recepción Técnica y Administrativa de Medicamentos.
 
Hospitality presentation nagelhout
Hospitality presentation nagelhoutHospitality presentation nagelhout
Hospitality presentation nagelhout
 
Calidad empresarial, mil std-105 e
Calidad empresarial, mil std-105 eCalidad empresarial, mil std-105 e
Calidad empresarial, mil std-105 e
 
Aseguramiento Calidad Expo
Aseguramiento Calidad   ExpoAseguramiento Calidad   Expo
Aseguramiento Calidad Expo
 
Muestreo Aceptacion por atributos Generalidades
Muestreo Aceptacion por atributos GeneralidadesMuestreo Aceptacion por atributos Generalidades
Muestreo Aceptacion por atributos Generalidades
 
Planes de muestreo
Planes de muestreoPlanes de muestreo
Planes de muestreo
 
Muestreo en control de calidad
Muestreo en control de calidadMuestreo en control de calidad
Muestreo en control de calidad
 
3.... acceptance sampling
3.... acceptance sampling3.... acceptance sampling
3.... acceptance sampling
 
Uso de la tabla mil std 105 d para definir planes de muestreo
Uso de la tabla mil std 105 d para definir planes de muestreoUso de la tabla mil std 105 d para definir planes de muestreo
Uso de la tabla mil std 105 d para definir planes de muestreo
 
Iso2859 1 muestreo inspeccion
Iso2859 1 muestreo inspeccionIso2859 1 muestreo inspeccion
Iso2859 1 muestreo inspeccion
 
Presentación ale
Presentación alePresentación ale
Presentación ale
 
Table mil std_414
Table mil std_414Table mil std_414
Table mil std_414
 

Similar to Tablas militares

Similar to Tablas militares (20)

Table_MIL_STD_105E.pdf
Table_MIL_STD_105E.pdfTable_MIL_STD_105E.pdf
Table_MIL_STD_105E.pdf
 
Production & Operation Management Chapter9[1]
Production & Operation Management Chapter9[1]Production & Operation Management Chapter9[1]
Production & Operation Management Chapter9[1]
 
Chapter9[1]
Chapter9[1]Chapter9[1]
Chapter9[1]
 
Statistical quality control
Statistical quality controlStatistical quality control
Statistical quality control
 
Distracter Analysis - Index of Effectiveness
Distracter Analysis - Index of EffectivenessDistracter Analysis - Index of Effectiveness
Distracter Analysis - Index of Effectiveness
 
14. Statistical Process Control.pptx
14. Statistical Process Control.pptx14. Statistical Process Control.pptx
14. Statistical Process Control.pptx
 
Med day presentation
Med day presentationMed day presentation
Med day presentation
 
SAT Practice Tests
SAT Practice TestsSAT Practice Tests
SAT Practice Tests
 
ch06.ppt
ch06.pptch06.ppt
ch06.ppt
 
Control charts
Control chartsControl charts
Control charts
 
Forecasting Assignment Help
Forecasting Assignment HelpForecasting Assignment Help
Forecasting Assignment Help
 
Statirstical Process Control in manufacturing
Statirstical Process Control in manufacturingStatirstical Process Control in manufacturing
Statirstical Process Control in manufacturing
 
control charts to enhance your problem solving abilities
control charts to enhance your problem solving abilitiescontrol charts to enhance your problem solving abilities
control charts to enhance your problem solving abilities
 
Ch04
Ch04Ch04
Ch04
 
Acceptance sampling Q&A
Acceptance sampling Q&AAcceptance sampling Q&A
Acceptance sampling Q&A
 
Statisticalqualitycontrol
StatisticalqualitycontrolStatisticalqualitycontrol
Statisticalqualitycontrol
 
Statisticalqualitycontrol
StatisticalqualitycontrolStatisticalqualitycontrol
Statisticalqualitycontrol
 
SQC PPT.pptx
SQC PPT.pptxSQC PPT.pptx
SQC PPT.pptx
 
Control Charts in Lab and Trend Analysis
Control Charts in Lab and Trend AnalysisControl Charts in Lab and Trend Analysis
Control Charts in Lab and Trend Analysis
 
Blackbeltpresentation
BlackbeltpresentationBlackbeltpresentation
Blackbeltpresentation
 

Recently uploaded

Book Call Girls in Panchpota - 8250192130 | 24x7 Service Available Near Me
Book Call Girls in Panchpota - 8250192130 | 24x7 Service Available Near MeBook Call Girls in Panchpota - 8250192130 | 24x7 Service Available Near Me
Book Call Girls in Panchpota - 8250192130 | 24x7 Service Available Near Meanamikaraghav4
 
👙 Kolkata Call Girls Sonagachi 💫💫7001035870 Model escorts Service
👙  Kolkata Call Girls Sonagachi 💫💫7001035870 Model escorts Service👙  Kolkata Call Girls Sonagachi 💫💫7001035870 Model escorts Service
👙 Kolkata Call Girls Sonagachi 💫💫7001035870 Model escorts Serviceanamikaraghav4
 
Model Call Girls In Pazhavanthangal WhatsApp Booking 7427069034 call girl ser...
Model Call Girls In Pazhavanthangal WhatsApp Booking 7427069034 call girl ser...Model Call Girls In Pazhavanthangal WhatsApp Booking 7427069034 call girl ser...
Model Call Girls In Pazhavanthangal WhatsApp Booking 7427069034 call girl ser... Shivani Pandey
 
Model Call Girls In Velappanchavadi WhatsApp Booking 7427069034 call girl ser...
Model Call Girls In Velappanchavadi WhatsApp Booking 7427069034 call girl ser...Model Call Girls In Velappanchavadi WhatsApp Booking 7427069034 call girl ser...
Model Call Girls In Velappanchavadi WhatsApp Booking 7427069034 call girl ser... Shivani Pandey
 
Science City Kolkata ( Call Girls ) Kolkata ✔ 6297143586 ✔ Hot Model With Sex...
Science City Kolkata ( Call Girls ) Kolkata ✔ 6297143586 ✔ Hot Model With Sex...Science City Kolkata ( Call Girls ) Kolkata ✔ 6297143586 ✔ Hot Model With Sex...
Science City Kolkata ( Call Girls ) Kolkata ✔ 6297143586 ✔ Hot Model With Sex...rahim quresi
 
Top Rated Kolkata Call Girls Khardah ⟟ 6297143586 ⟟ Call Me For Genuine Sex S...
Top Rated Kolkata Call Girls Khardah ⟟ 6297143586 ⟟ Call Me For Genuine Sex S...Top Rated Kolkata Call Girls Khardah ⟟ 6297143586 ⟟ Call Me For Genuine Sex S...
Top Rated Kolkata Call Girls Khardah ⟟ 6297143586 ⟟ Call Me For Genuine Sex S...ritikasharma
 
Call Girls Agency In Goa 💚 9316020077 💚 Call Girl Goa By Russian Call Girl ...
Call Girls  Agency In Goa  💚 9316020077 💚 Call Girl Goa By Russian Call Girl ...Call Girls  Agency In Goa  💚 9316020077 💚 Call Girl Goa By Russian Call Girl ...
Call Girls Agency In Goa 💚 9316020077 💚 Call Girl Goa By Russian Call Girl ...russian goa call girl and escorts service
 
Call Girls Service Bantala - Call 8250192130 Rs-3500 with A/C Room Cash on De...
Call Girls Service Bantala - Call 8250192130 Rs-3500 with A/C Room Cash on De...Call Girls Service Bantala - Call 8250192130 Rs-3500 with A/C Room Cash on De...
Call Girls Service Bantala - Call 8250192130 Rs-3500 with A/C Room Cash on De...anamikaraghav4
 
👙 Kolkata Call Girls Shyam Bazar 💫💫7001035870 Model escorts Service
👙  Kolkata Call Girls Shyam Bazar 💫💫7001035870 Model escorts Service👙  Kolkata Call Girls Shyam Bazar 💫💫7001035870 Model escorts Service
👙 Kolkata Call Girls Shyam Bazar 💫💫7001035870 Model escorts Serviceanamikaraghav4
 
↑Top Model (Kolkata) Call Girls Rajpur ⟟ 8250192130 ⟟ High Class Call Girl In...
↑Top Model (Kolkata) Call Girls Rajpur ⟟ 8250192130 ⟟ High Class Call Girl In...↑Top Model (Kolkata) Call Girls Rajpur ⟟ 8250192130 ⟟ High Class Call Girl In...
↑Top Model (Kolkata) Call Girls Rajpur ⟟ 8250192130 ⟟ High Class Call Girl In...noor ahmed
 
Top Rated Pune Call Girls Pimpri Chinchwad ⟟ 6297143586 ⟟ Call Me For Genuin...
Top Rated  Pune Call Girls Pimpri Chinchwad ⟟ 6297143586 ⟟ Call Me For Genuin...Top Rated  Pune Call Girls Pimpri Chinchwad ⟟ 6297143586 ⟟ Call Me For Genuin...
Top Rated Pune Call Girls Pimpri Chinchwad ⟟ 6297143586 ⟟ Call Me For Genuin...Call Girls in Nagpur High Profile
 
Russian Call Girl South End Park - Call 8250192130 Rs-3500 with A/C Room Cash...
Russian Call Girl South End Park - Call 8250192130 Rs-3500 with A/C Room Cash...Russian Call Girl South End Park - Call 8250192130 Rs-3500 with A/C Room Cash...
Russian Call Girl South End Park - Call 8250192130 Rs-3500 with A/C Room Cash...anamikaraghav4
 
Dakshineswar Call Girls ✔ 8005736733 ✔ Hot Model With Sexy Bhabi Ready For Se...
Dakshineswar Call Girls ✔ 8005736733 ✔ Hot Model With Sexy Bhabi Ready For Se...Dakshineswar Call Girls ✔ 8005736733 ✔ Hot Model With Sexy Bhabi Ready For Se...
Dakshineswar Call Girls ✔ 8005736733 ✔ Hot Model With Sexy Bhabi Ready For Se...aamir
 
VIP Call Girls Nagpur Megha Call 7001035870 Meet With Nagpur Escorts
VIP Call Girls Nagpur Megha Call 7001035870 Meet With Nagpur EscortsVIP Call Girls Nagpur Megha Call 7001035870 Meet With Nagpur Escorts
VIP Call Girls Nagpur Megha Call 7001035870 Meet With Nagpur Escortsranjana rawat
 
Call Girls in Barasat | 7001035870 At Low Cost Cash Payment Booking
Call Girls in Barasat | 7001035870 At Low Cost Cash Payment BookingCall Girls in Barasat | 7001035870 At Low Cost Cash Payment Booking
Call Girls in Barasat | 7001035870 At Low Cost Cash Payment Bookingnoor ahmed
 
College Call Girls New Alipore - For 7001035870 Cheap & Best with original Ph...
College Call Girls New Alipore - For 7001035870 Cheap & Best with original Ph...College Call Girls New Alipore - For 7001035870 Cheap & Best with original Ph...
College Call Girls New Alipore - For 7001035870 Cheap & Best with original Ph...anamikaraghav4
 
VIP Call Girls Sonagachi - 8250192130 Escorts Service 50% Off with Cash ON De...
VIP Call Girls Sonagachi - 8250192130 Escorts Service 50% Off with Cash ON De...VIP Call Girls Sonagachi - 8250192130 Escorts Service 50% Off with Cash ON De...
VIP Call Girls Sonagachi - 8250192130 Escorts Service 50% Off with Cash ON De...anamikaraghav4
 

Recently uploaded (20)

Book Call Girls in Panchpota - 8250192130 | 24x7 Service Available Near Me
Book Call Girls in Panchpota - 8250192130 | 24x7 Service Available Near MeBook Call Girls in Panchpota - 8250192130 | 24x7 Service Available Near Me
Book Call Girls in Panchpota - 8250192130 | 24x7 Service Available Near Me
 
👙 Kolkata Call Girls Sonagachi 💫💫7001035870 Model escorts Service
👙  Kolkata Call Girls Sonagachi 💫💫7001035870 Model escorts Service👙  Kolkata Call Girls Sonagachi 💫💫7001035870 Model escorts Service
👙 Kolkata Call Girls Sonagachi 💫💫7001035870 Model escorts Service
 
Model Call Girls In Pazhavanthangal WhatsApp Booking 7427069034 call girl ser...
Model Call Girls In Pazhavanthangal WhatsApp Booking 7427069034 call girl ser...Model Call Girls In Pazhavanthangal WhatsApp Booking 7427069034 call girl ser...
Model Call Girls In Pazhavanthangal WhatsApp Booking 7427069034 call girl ser...
 
Model Call Girls In Velappanchavadi WhatsApp Booking 7427069034 call girl ser...
Model Call Girls In Velappanchavadi WhatsApp Booking 7427069034 call girl ser...Model Call Girls In Velappanchavadi WhatsApp Booking 7427069034 call girl ser...
Model Call Girls In Velappanchavadi WhatsApp Booking 7427069034 call girl ser...
 
Science City Kolkata ( Call Girls ) Kolkata ✔ 6297143586 ✔ Hot Model With Sex...
Science City Kolkata ( Call Girls ) Kolkata ✔ 6297143586 ✔ Hot Model With Sex...Science City Kolkata ( Call Girls ) Kolkata ✔ 6297143586 ✔ Hot Model With Sex...
Science City Kolkata ( Call Girls ) Kolkata ✔ 6297143586 ✔ Hot Model With Sex...
 
Top Rated Kolkata Call Girls Khardah ⟟ 6297143586 ⟟ Call Me For Genuine Sex S...
Top Rated Kolkata Call Girls Khardah ⟟ 6297143586 ⟟ Call Me For Genuine Sex S...Top Rated Kolkata Call Girls Khardah ⟟ 6297143586 ⟟ Call Me For Genuine Sex S...
Top Rated Kolkata Call Girls Khardah ⟟ 6297143586 ⟟ Call Me For Genuine Sex S...
 
Desi Bhabhi Call Girls In Goa 💃 730 02 72 001💃desi Bhabhi Escort Goa
Desi Bhabhi Call Girls  In Goa  💃 730 02 72 001💃desi Bhabhi Escort GoaDesi Bhabhi Call Girls  In Goa  💃 730 02 72 001💃desi Bhabhi Escort Goa
Desi Bhabhi Call Girls In Goa 💃 730 02 72 001💃desi Bhabhi Escort Goa
 
Call Girls Agency In Goa 💚 9316020077 💚 Call Girl Goa By Russian Call Girl ...
Call Girls  Agency In Goa  💚 9316020077 💚 Call Girl Goa By Russian Call Girl ...Call Girls  Agency In Goa  💚 9316020077 💚 Call Girl Goa By Russian Call Girl ...
Call Girls Agency In Goa 💚 9316020077 💚 Call Girl Goa By Russian Call Girl ...
 
Call Girls Service Bantala - Call 8250192130 Rs-3500 with A/C Room Cash on De...
Call Girls Service Bantala - Call 8250192130 Rs-3500 with A/C Room Cash on De...Call Girls Service Bantala - Call 8250192130 Rs-3500 with A/C Room Cash on De...
Call Girls Service Bantala - Call 8250192130 Rs-3500 with A/C Room Cash on De...
 
👙 Kolkata Call Girls Shyam Bazar 💫💫7001035870 Model escorts Service
👙  Kolkata Call Girls Shyam Bazar 💫💫7001035870 Model escorts Service👙  Kolkata Call Girls Shyam Bazar 💫💫7001035870 Model escorts Service
👙 Kolkata Call Girls Shyam Bazar 💫💫7001035870 Model escorts Service
 
Call Girls Chirag Delhi Delhi WhatsApp Number 9711199171
Call Girls Chirag Delhi Delhi WhatsApp Number 9711199171Call Girls Chirag Delhi Delhi WhatsApp Number 9711199171
Call Girls Chirag Delhi Delhi WhatsApp Number 9711199171
 
↑Top Model (Kolkata) Call Girls Rajpur ⟟ 8250192130 ⟟ High Class Call Girl In...
↑Top Model (Kolkata) Call Girls Rajpur ⟟ 8250192130 ⟟ High Class Call Girl In...↑Top Model (Kolkata) Call Girls Rajpur ⟟ 8250192130 ⟟ High Class Call Girl In...
↑Top Model (Kolkata) Call Girls Rajpur ⟟ 8250192130 ⟟ High Class Call Girl In...
 
Top Rated Pune Call Girls Pimpri Chinchwad ⟟ 6297143586 ⟟ Call Me For Genuin...
Top Rated  Pune Call Girls Pimpri Chinchwad ⟟ 6297143586 ⟟ Call Me For Genuin...Top Rated  Pune Call Girls Pimpri Chinchwad ⟟ 6297143586 ⟟ Call Me For Genuin...
Top Rated Pune Call Girls Pimpri Chinchwad ⟟ 6297143586 ⟟ Call Me For Genuin...
 
Russian Call Girl South End Park - Call 8250192130 Rs-3500 with A/C Room Cash...
Russian Call Girl South End Park - Call 8250192130 Rs-3500 with A/C Room Cash...Russian Call Girl South End Park - Call 8250192130 Rs-3500 with A/C Room Cash...
Russian Call Girl South End Park - Call 8250192130 Rs-3500 with A/C Room Cash...
 
Dakshineswar Call Girls ✔ 8005736733 ✔ Hot Model With Sexy Bhabi Ready For Se...
Dakshineswar Call Girls ✔ 8005736733 ✔ Hot Model With Sexy Bhabi Ready For Se...Dakshineswar Call Girls ✔ 8005736733 ✔ Hot Model With Sexy Bhabi Ready For Se...
Dakshineswar Call Girls ✔ 8005736733 ✔ Hot Model With Sexy Bhabi Ready For Se...
 
Goa Call Girls 9316020077 Call Girls In Goa By Russian Call Girl in goa
Goa Call Girls 9316020077 Call Girls  In Goa By Russian Call Girl in goaGoa Call Girls 9316020077 Call Girls  In Goa By Russian Call Girl in goa
Goa Call Girls 9316020077 Call Girls In Goa By Russian Call Girl in goa
 
VIP Call Girls Nagpur Megha Call 7001035870 Meet With Nagpur Escorts
VIP Call Girls Nagpur Megha Call 7001035870 Meet With Nagpur EscortsVIP Call Girls Nagpur Megha Call 7001035870 Meet With Nagpur Escorts
VIP Call Girls Nagpur Megha Call 7001035870 Meet With Nagpur Escorts
 
Call Girls in Barasat | 7001035870 At Low Cost Cash Payment Booking
Call Girls in Barasat | 7001035870 At Low Cost Cash Payment BookingCall Girls in Barasat | 7001035870 At Low Cost Cash Payment Booking
Call Girls in Barasat | 7001035870 At Low Cost Cash Payment Booking
 
College Call Girls New Alipore - For 7001035870 Cheap & Best with original Ph...
College Call Girls New Alipore - For 7001035870 Cheap & Best with original Ph...College Call Girls New Alipore - For 7001035870 Cheap & Best with original Ph...
College Call Girls New Alipore - For 7001035870 Cheap & Best with original Ph...
 
VIP Call Girls Sonagachi - 8250192130 Escorts Service 50% Off with Cash ON De...
VIP Call Girls Sonagachi - 8250192130 Escorts Service 50% Off with Cash ON De...VIP Call Girls Sonagachi - 8250192130 Escorts Service 50% Off with Cash ON De...
VIP Call Girls Sonagachi - 8250192130 Escorts Service 50% Off with Cash ON De...
 

Tablas militares

  • 1. KUMPULAN TABEL MIL-STD-105E Ir. Budi Nurtama, M.Agr. 2008 Program Studi Supervisor Jaminan Mutu Pangan PROGRAM DIPLOMA Institut Pertanian Bogor
  • 2. Tables for MIL-STD-105E *) Page Table I. Sample-Size Code Letters. 1 Table II-A. Single Sampling Plans for Normal Inspection (Master Table). 2 Table II-B. Single Sampling Plans for Tightened Inspection (Master Table). 3 Table II-C. Single Sampling Plans for Reduced Inspection (Master Table). 4 Table III-A. Double Sampling Plans for Normal Inspection (Master Table). 5 Table III-B. Double Sampling Plans for Tightened Inspection (Master Table). 6 Table III-C. Double Sampling Plans for Reduced Inspection (Master Table). 7 Table IV-A. Multiple Sampling Plans for Normal Inspection (Master Table). 8 Table IV-A.(continued) 9 Table IV-B. Multiple Sampling Plans for Tightened Inspection (Master Table). 10 Table IV-B.(continued). 11 Table IV-C. Multiple Sampling Plans for Reduced Inspection (Master Table). 12 Table IV-C.(continued). 13 Table V-A. Average Outgoing Quality Limit Factors for Normal Inspection (Single Sampling). 14 Table V-A. Average Outgoing Quality Limit Factors for Tightened Inspection (Single Sampling). 15 Table VIII. Limit Numbers for Reduced Inspection. 16 *) Farnum, Nicholas R. 1994. Modern Statistical Quality Control and Improvement. Wadsworth, Inc., California. i
  • 3. Tahapan Implementasi MIL-STD-105E 1. Tentukan AQL (Acceptable Quality Level) berdasarkan perjanjian produsen dan pelanggan. 2. Tetapkan modus dan tingkat inspeksi (jika tidak, gunakan Normal Inspection, Level II ). 3. Tentukan ukuran lot (lot size). 4. Gunakan tabel Sample Size Code Letters untuk memilih huruf kode yang sesuai. 5. Tetapkan tipe prosedur pengambilan sampel : single, double, atau multiple sampling. 6. Gunakan tabel yang berkaitan dengan prosedur pengambilan sampel terpilih (tahap 5) dan modus/tingkat inspeksi (tahap 2) untuk mendapatkan ukuran sampel dan angka penerimaan (Ac) serta angka penolakan (Re). Dalam kasus dimana suatu rancangan tidak ada untuk ukuran lot dan AQL-nya, hati-hati mengikuti tanda panah dalam tabel ke rancangan terdekat yang ada. 7. Mulailah gunakan rancangan tersebut dan catat penerimaan dan penolakan sehingga switching rule dapat diterapkan. Jika switching dilakukan, tentukan modus dan tingkat dan ulangi tahap 4-6 untuk mendapatkan rancangan pengambilan sampel yang baru. SWITCHING RULE for MIL-STD-105E • Dari Normal ke Tightened Inspection : setelah 2 lot ditolak dari 2, 3, 4, atau 5 lot berurutan • Dari Tightened ke Normal Inspection : setelah 5 lot berurutan diterima • Dari Normal ke Reduced Inspection : jika (i) 10 lot berurutan diterima, dan (ii) jumlah total nonconforming items dalam 10 lot tersebut tidak melebihi batas pada Table VIII. Limit Numbers for Reduced Inspection., dan (iii) produksi stabil/mantap, dan (iv) disetujui oleh otoritas yang bertanggungjawab. • Dari Reduced ke Normal Inspection : jika (i) suatu lot tunggal ditolak, atau (ii) suatu lot hanya sebagian dapat diterima (dhi. jumlah nonconforming items diantara angka diterima dan ditolak), atau (iii) produksi menjadi tidak stabil, atau (iv) kondisi-kondisi lain yang menjamin bahwa inspeksi Normal dapat dilakukan. ii
  • 4. Table I. Sample-Size Code Letters. Special Inspection Levels General Inspection Levels Lot or batch size S-1 S-2 S-3 S-4 I II III 2 to 8 A A A A A A B 9 to 15 A A A A A B C 16 to 25 A A B B B C D 26 to 50 A B B C C D E 51 to 90 B B C C C E F 91 to 150 B B C D D F G 151 to 280 B C D E E G H 281 to 500 B C D E F H J 501 to 1,200 C C E F G J K 1,201 to 3,200 C D E G H K L 3,201 to 10,000 C D F G J L M 10,001 to 35,000 C D F H K M N 35,001 to 150,000 D E G J L N P 150,001 to 500,000 D E G J M P Q 500,001 and over D E H K N Q R 1
  • 5. Table II - A. Single Sampling Plans for Normal Inspection (Master Table). Acceptable Quality Levels (normal inspection) Sample size Sample 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000 size code letter Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re A 2 B 3 C 5 D 8 E 13 F 20 G 32 H 50 J 80 K 125 L 200 M 315 N 500 P 800 Q 1250 R 2000 0 1 1 2 2 3 3 4 5 6 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 30 31 44 45 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 30 31 44 45 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 30 31 44 45 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 30 31 44 45 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 2 3 3 4 5 6 7 8 10 11 14 15 21 22 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 2 = Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection. Ac = Acceptance number. = Use first sampling plan above arrow. 7 8 10 11 14 15 21 22 30 31 Re = Rejection number. 2
  • 6. Table II - B. Single Sampling Plans for Tightened Inspection (Master Table). Acceptable Quality Levels (tightened inspection) Sample size Sample 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000 size code letter Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re A 2 B 3 C 5 D 8 E 13 F 20 G 32 H 50 J 80 K 125 L 200 M 315 N 500 P 800 Q 1250 R 2000 S 3150 1 2 2 3 3 4 5 6 1 2 2 3 3 4 5 6 8 9 12 13 18 19 27 28 41 42 1 2 2 3 3 4 5 6 8 9 12 13 18 19 27 28 41 42 1 2 2 3 3 4 5 6 8 9 12 13 18 19 27 28 41 42 1 2 2 3 3 4 5 6 8 9 12 13 18 19 27 28 41 42 1 2 2 3 3 4 5 6 8 9 12 13 18 19 1 2 2 3 3 4 5 6 8 9 12 13 18 19 1 2 2 3 3 4 5 6 8 9 12 13 18 19 1 2 2 3 3 4 5 6 8 9 12 13 18 19 1 2 2 3 3 4 5 6 8 9 12 13 18 19 1 2 2 3 3 4 5 6 8 9 12 13 18 19 1 2 2 3 3 4 5 6 8 9 12 13 18 19 1 2 2 3 3 4 5 6 8 9 12 13 18 19 1 2 2 3 3 4 5 6 8 9 12 13 18 19 1 2 2 3 3 4 5 6 8 9 12 13 18 19 2 3 3 4 5 6 8 9 12 13 18 19 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 2 8 9 12 13 18 19 27 28 1 2 = Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection. Ac = Acceptance number. = Use first sampling plan above arrow. Re = Rejection number. 3
  • 7. Table II - C. Single Sampling Plans for Reduced Inspection (Master Table). Acceptable Quality Levels (reduced inspection) Sample size Sample 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000 size code letter Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re A 2 B 2 C 2 D 3 E 5 F 8 G 13 H 20 J 32 K 50 L 80 M 125 N 200 P 315 Q 500 R 800 0 1 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22 30 31 0 2 1 3 2 4 3 5 5 6 7 8 10 11 14 15 21 22 30 31 0 2 1 3 1 4 2 5 3 6 5 8 7 10 10 13 14 17 21 24 0 2 1 3 1 4 2 5 3 6 5 8 7 10 10 13 14 17 21 24 0 2 1 3 1 4 2 5 3 6 5 8 7 10 10 13 14 17 21 24 0 2 1 3 1 4 2 5 3 6 5 8 7 10 10 13 0 2 1 3 1 4 2 5 3 6 5 8 7 10 10 13 0 2 1 3 1 4 2 5 3 6 5 8 7 10 10 13 0 2 1 3 1 4 2 5 3 6 5 8 7 10 10 13 0 2 1 3 1 4 2 5 3 6 5 8 7 10 10 13 0 2 1 3 1 4 2 5 3 6 5 8 7 10 10 13 0 2 1 3 1 4 2 5 3 6 5 8 7 10 10 13 0 2 1 3 1 4 2 5 3 6 5 8 7 10 10 13 0 2 1 3 1 4 2 5 3 6 5 8 7 10 10 13 0 2 1 3 1 4 2 5 3 6 5 8 7 10 10 13 1 3 1 4 2 5 3 6 5 8 7 10 10 13 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 2 = Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection. Ac = Acceptance number. = Use first sampling plan above arrow. = If the acceptance number has been exceeded, but the rejection number has not been reached; accept the lot, but reinstate normal inspection. Re = Rejection number. 4
  • 8. Table III - A. Double Sampling Plans for Normal Inspection (Master Table). Acceptable Quality Levels (normal inspection) Sample Cumula size Sample tive Sample 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000 code size sample letter size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re A B First Second 2 2 2 4 C First Second 3 3 3 6 D First Second 5 5 5 10 E First Second 8 8 8 16 F First Second 13 13 13 26 G First Second 20 20 20 40 H First Second 32 32 32 64 J First Second 50 50 50 100 K First Second 80 80 80 160 L First Second 125 125 125 250 M First Second 200 200 200 400 N First Second 315 315 315 630 P First Second 500 500 500 1000 Q First Second 800 800 800 1600 R First 1250 Second 1250 1250 2500 0 2 1 2 1 4 4 5 2 5 6 7 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 3 7 8 9 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 3 7 8 9 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 3 7 8 9 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 3 7 8 9 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 3 7 8 9 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 3 7 8 9 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 3 7 8 9 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 3 7 8 9 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 3 7 8 9 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 3 7 8 9 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 3 7 8 9 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 3 7 5 9 7 11 11 16 8 9 12 13 18 19 26 27 0 2 1 2 0 2 1 2 0 3 3 4 0 3 3 4 1 4 4 5 2 5 6 7 3 7 8 9 0 3 3 4 1 4 4 5 2 5 6 7 3 7 8 9 3 7 8 9 5 9 7 11 11 16 17 22 25 31 12 13 18 19 26 27 37 38 56 57 5 9 7 11 11 16 17 22 25 31 12 13 18 19 26 27 37 38 56 57 5 9 7 11 11 16 17 22 25 31 12 13 18 19 26 27 37 38 56 57 5 9 7 11 11 16 17 22 25 31 12 13 18 19 26 27 37 38 56 57 5 9 7 11 11 16 12 13 18 19 26 27 5 9 7 11 11 16 12 13 18 19 26 27 5 9 7 11 11 16 12 13 18 19 26 27 5 9 7 11 11 16 12 13 18 19 26 27 5 9 7 11 11 16 12 13 18 19 26 27 5 9 7 11 11 16 12 13 18 19 26 27 5 9 7 11 11 16 12 13 18 19 26 27 5 9 7 11 11 16 12 13 18 19 26 27 5 9 7 11 11 16 12 13 18 19 26 27 5 9 7 11 11 16 12 13 18 19 26 27 = Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection. = Use first sampling plan above arrow. = Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available). Ac = Acceptance number. Re = Rejection number. 5
  • 9. Table III - B. Double Sampling Plans for Tightened Inspection (Master Table). Acceptable Quality Levels (normal inspection) Sample Cumula size Sample tive Sample 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000 code size sample letter size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re A B First Second 2 2 2 4 C First Second 3 3 3 6 D First Second 5 5 5 10 E First Second 8 8 8 16 F First Second 13 13 13 26 G First Second 20 20 20 40 H First Second 32 32 32 64 J First Second 50 50 50 100 K First Second 80 80 80 160 L First Second 125 125 125 250 M First Second 200 200 200 400 N First Second 315 315 315 630 P First Second 500 500 500 1000 Q First Second 800 800 800 1600 R First 1250 Second 1250 1250 2500 S First 2000 Second 2000 2000 4000 0 2 1 2 1 4 4 5 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 0 2 1 2 0 3 3 4 1 4 4 5 2 5 3 7 6 10 9 14 6 7 11 12 15 16 23 24 0 2 1 2 0 3 3 4 1 4 4 5 2 5 6 7 0 2 1 2 0 3 3 4 1 4 4 5 2 5 3 7 6 10 9 14 6 7 11 12 15 16 23 24 0 2 1 2 0 2 1 2 0 3 3 4 0 3 3 4 1 4 4 5 2 5 6 7 0 3 3 4 1 4 4 5 2 5 6 7 2 5 6 7 3 7 6 10 9 14 15 20 23 29 11 12 15 16 23 24 34 35 52 53 3 7 6 10 9 14 15 20 23 29 11 12 15 16 23 24 34 35 52 53 3 7 6 10 9 14 15 20 23 29 11 12 15 16 23 24 34 35 52 53 3 7 6 10 9 14 15 20 23 29 11 12 15 16 23 24 34 35 52 53 3 7 6 10 9 14 11 12 15 16 23 24 3 7 6 10 9 14 11 12 15 16 23 24 3 7 6 10 9 14 11 12 15 16 23 24 3 7 6 10 9 14 11 12 15 16 23 24 3 7 6 10 9 14 11 12 15 16 23 24 3 7 6 10 9 14 11 12 15 16 23 24 3 7 6 10 9 14 11 12 15 16 23 24 3 7 6 10 9 14 11 12 15 16 23 24 3 7 6 10 9 14 11 12 15 16 23 24 0 2 1 2 = Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection. = Use first sampling plan above arrow. = Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available). Ac = Acceptance number. Re = Rejection number. 6
  • 10. Table III - C. Double Sampling Plans for Reduced Inspection (Master Table). Acceptable Quality Levels (reduced inspection) Sample Cumula size Sample tive Sample 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000 code size sample letter size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re A B C D First Second 2 2 2 4 E First Second 3 3 3 6 F First Second 5 5 5 10 G First Second 8 8 8 16 H First Second 13 13 13 26 J First Second 20 20 20 40 K First Second 32 32 32 64 L First Second 50 50 50 100 M First Second 80 80 80 160 N First Second 125 125 125 250 P First Second 200 200 200 400 Q First Second 315 315 315 630 R First Second 500 500 500 1000 = = Ac = Re = = = 0 2 0 2 0 4 1 5 0 4 3 6 1 5 4 7 2 7 6 9 0 2 0 2 0 3 0 4 0 4 1 5 0 4 3 6 1 5 4 7 2 7 6 9 3 8 5 10 7 12 11 17 8 12 12 16 18 22 26 30 0 2 0 2 0 3 0 4 0 4 1 5 0 4 3 6 1 5 4 7 2 7 6 9 3 8 5 10 8 12 12 16 0 2 0 2 0 3 0 4 0 4 1 5 0 4 3 6 1 5 4 7 2 7 6 9 3 8 5 10 8 12 12 16 0 2 0 2 0 3 0 4 0 4 1 5 0 4 3 6 1 5 4 7 2 7 6 9 3 8 5 10 8 12 12 16 0 2 0 2 0 3 0 4 0 4 1 5 0 4 3 6 1 5 4 7 2 7 6 9 3 8 5 10 8 12 12 16 0 2 0 2 0 3 0 4 0 4 1 5 0 4 3 6 1 5 4 7 2 7 6 9 3 8 5 10 8 12 12 16 0 2 0 2 0 3 0 4 0 4 1 5 0 4 3 6 1 5 4 7 2 7 6 9 3 8 5 10 8 12 12 16 0 2 0 2 0 3 0 4 0 4 1 5 0 4 3 6 1 5 4 7 2 7 6 9 3 8 5 10 8 12 12 16 0 2 0 2 0 3 0 4 0 4 1 5 0 4 3 6 1 5 4 7 2 7 6 9 3 8 5 10 8 12 12 16 0 2 0 2 0 3 0 4 0 4 1 5 0 4 3 6 1 5 4 7 2 7 6 9 3 8 5 10 8 12 12 16 0 2 0 2 0 2 0 2 0 3 0 4 3 8 5 10 7 12 11 17 8 12 12 16 18 22 26 30 0 3 0 4 0 4 1 5 0 4 3 6 1 5 4 7 2 7 6 9 3 8 5 10 8 12 12 16 0 3 0 4 0 4 1 5 0 4 3 6 1 5 4 7 2 7 6 9 3 8 5 10 8 12 12 16 Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection. Use first sampling plan above arrow. Acceptance number. Rejection number. Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available). If, after the second sample, the acceptance number has been exceeded, but the rejection number has not been reached, accept the lot, but reinstate normal inspection. 7
  • 11. Table IV - A. Multiple Sampling Plans for Normal Inspection (Master Table). Acceptable Quality Levels (normal inspection) Sample Cumula size Sample tive Sample 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000 code size sample letter size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re A B C D E F G H J First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh 2 2 2 2 2 2 2 3 3 3 3 3 3 3 5 5 5 5 5 5 5 8 8 8 8 8 8 8 13 13 13 13 13 13 13 20 20 20 20 20 20 20 2 4 6 8 10 12 14 3 6 9 12 15 18 21 5 10 15 20 25 30 35 8 16 24 32 40 48 56 13 26 39 52 65 78 91 20 40 60 80 100 120 140 # # 0 0 1 1 2 2 2 2 3 3 3 3 # # 0 0 1 1 2 # 0 0 1 2 3 4 2 2 2 3 3 3 3 2 3 3 4 4 5 5 # # 0 0 1 1 2 # 0 0 1 2 3 4 # 0 1 2 3 4 6 2 2 2 3 3 3 3 2 3 3 4 4 5 5 3 3 4 5 6 6 7 # # 0 0 1 1 2 # 0 0 1 2 3 4 # 0 1 2 3 4 6 # 1 2 3 5 7 9 # 2 # 2 0 2 0 3 1 3 1 3 2 3 2 # 2 2 0 3 2 0 3 3 1 4 3 2 4 3 3 5 3 4 5 2 # 3 3 0 3 3 1 4 4 2 5 4 3 6 5 4 6 5 6 7 3 # 4 3 1 5 4 2 6 5 3 7 6 5 8 6 7 9 7 9 10 4 0 4 5 1 6 6 3 8 7 5 10 8 7 11 9 10 12 10 13 14 # 2 # 2 0 2 0 3 1 3 1 3 2 3 # 2 0 3 0 3 1 4 2 4 3 5 4 5 # 3 0 3 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 1 6 3 8 5 10 7 11 10 12 13 14 0 5 3 8 6 10 8 13 11 15 14 17 18 19 ++ # 2 0 3 0 3 1 4 2 4 3 5 4 5 # 3 0 3 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 1 6 3 8 5 10 7 11 10 12 13 14 0 5 3 8 6 10 8 13 11 15 14 17 18 19 1 7 4 10 8 13 12 17 17 20 21 23 25 26 ++ ++ # 3 0 3 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 1 6 3 8 5 10 7 11 10 12 13 14 0 5 3 8 6 10 8 13 11 15 14 17 18 19 1 7 4 10 8 13 12 17 17 20 21 23 25 26 2 9 7 14 13 19 19 25 25 29 31 33 37 38 ++ ++ # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 1 6 3 8 5 10 7 11 10 12 13 14 0 5 3 8 6 10 8 13 11 15 14 17 18 19 1 7 4 10 8 13 12 17 17 20 21 23 25 26 2 9 7 14 13 19 19 25 25 29 31 33 37 38 ++ ++ 0 4 1 6 3 8 5 10 7 11 10 12 13 14 0 5 3 8 6 10 8 13 11 15 14 17 18 19 1 7 4 10 8 13 12 17 17 20 21 23 25 26 2 9 7 14 13 19 19 25 25 29 31 33 37 38 = Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection. = Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available). Ac = Acceptance number. ++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available). # = Acceptance not permitted at this sample size. ++ ++ 0 5 3 8 6 10 8 13 11 15 14 17 18 19 1 7 4 10 8 13 12 17 17 20 21 23 25 26 2 9 7 14 13 19 19 25 25 29 31 33 37 38 ++ ++ 1 7 4 10 8 13 12 17 17 20 21 23 25 26 2 9 7 14 13 19 19 25 25 29 31 33 37 38 ++ ++ 2 9 7 14 13 19 19 25 25 29 31 33 37 38 4 12 11 19 19 27 27 34 36 40 45 47 53 54 ++ ++ 4 12 11 19 19 27 27 34 36 40 45 47 53 54 6 16 17 27 29 39 40 49 53 58 65 68 77 78 ++ ++ 6 16 17 27 29 39 40 49 53 58 65 68 77 78 ++ ++ ++ = Use first sampling plan above arrow. Re = Rejection number. 8
  • 12. Table IV - A. (continued). Acceptable Quality Levels (normal inspection Sample Cumula size Sample tive 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 Sample code size sample letter size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re K L M N P Q R First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh 32 32 32 32 32 32 32 50 50 50 50 50 50 50 80 80 80 80 80 80 80 125 125 125 125 125 125 125 200 200 200 200 200 200 200 315 315 315 315 315 315 315 500 500 500 500 500 500 500 32 64 96 128 160 192 224 50 100 150 200 250 300 350 80 160 240 320 400 480 560 125 250 375 500 625 750 875 200 400 600 800 1000 1200 1400 315 630 945 1260 1575 1890 2205 500 1000 1500 2000 2500 3000 3500 # # 0 0 1 1 2 2 2 2 3 3 3 3 # # 0 0 1 1 2 # 0 0 1 2 3 4 2 2 2 3 3 3 3 2 3 3 4 4 5 5 # # 0 0 1 1 2 # 0 0 1 2 3 4 # 0 1 2 3 4 6 2 2 2 3 3 3 3 2 3 3 4 4 5 5 3 3 4 5 6 6 7 # # 0 0 1 1 2 # 0 0 1 2 3 4 # 0 1 2 3 4 6 # 1 2 3 5 7 9 # 2 # 2 0 2 0 3 1 3 1 3 2 3 2 # 2 2 0 3 2 0 3 3 1 4 3 2 4 3 3 5 3 4 5 2 # 3 3 0 3 3 1 4 4 2 5 4 3 6 5 4 6 5 6 7 3 # 4 3 1 5 4 2 6 5 3 7 6 5 8 6 7 9 7 9 10 4 0 4 5 1 6 6 3 8 7 5 10 8 7 11 9 10 12 10 13 14 # 2 # 2 0 2 0 3 1 3 1 3 2 3 # 2 0 3 0 3 1 4 2 4 3 5 4 5 # 3 0 3 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 1 6 3 8 5 10 7 11 10 12 13 14 0 5 3 8 6 10 8 13 11 15 14 17 18 19 # 2 # 2 0 2 0 3 1 3 1 3 2 3 # 2 0 3 0 3 1 4 2 4 3 5 4 5 # 3 0 3 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 1 6 3 8 5 10 7 11 10 12 13 14 0 5 3 8 6 10 8 13 11 15 14 17 18 19 1 7 4 10 8 13 12 17 17 20 21 23 25 26 # 2 0 3 0 3 1 4 2 4 3 5 4 5 # 3 0 3 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 1 6 3 8 5 10 7 11 10 12 13 14 0 5 3 8 6 10 8 13 11 15 14 17 18 19 1 7 4 10 8 13 12 17 17 20 21 23 25 26 2 9 7 14 13 19 19 25 25 29 31 33 37 38 # 3 0 3 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 1 6 3 8 5 10 7 11 10 12 13 14 0 5 3 8 6 10 8 13 11 15 14 17 18 19 1 7 4 10 8 13 12 17 17 20 21 23 25 26 2 9 7 14 13 19 19 25 25 29 31 33 37 38 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 1 6 3 8 5 10 7 11 10 12 13 14 0 5 3 8 6 10 8 13 11 15 14 17 18 19 1 7 4 10 8 13 12 17 17 20 21 23 25 26 2 9 7 14 13 19 19 25 25 29 31 33 37 38 0 1 3 5 7 10 13 0 3 6 8 11 14 18 1 4 8 12 17 21 25 2 7 13 19 25 31 37 4 6 8 10 11 12 14 5 8 10 13 15 17 19 7 10 13 17 20 23 26 9 14 19 25 29 33 38 0 3 6 8 11 14 18 1 4 8 12 17 21 25 2 7 13 19 25 31 37 5 8 10 13 15 17 19 7 10 13 17 20 23 26 9 14 19 25 29 33 38 1 4 8 12 17 21 25 2 7 13 19 25 31 37 7 10 13 17 20 23 26 9 14 19 25 29 33 38 2 7 13 19 25 31 37 9 14 19 25 29 33 38 = Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 1 = Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available). Ac = Acceptance number. ++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available). # = Acceptance not permitte
  • 13. Table IV - B. Multiple Sampling Plans for Tightened Inspection (Master Table). Acceptable Quality Levels (tightened inspection) Sample Cumula size Sample tive Sample 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000 code size sample letter size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re A B C D E F G H J First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh 2 2 2 2 2 2 2 3 3 3 3 3 3 3 5 5 5 5 5 5 5 8 8 8 8 8 8 8 13 13 13 13 13 13 13 20 20 20 20 20 20 20 2 4 6 8 10 12 14 3 6 9 12 15 18 21 5 10 15 20 25 30 35 8 16 24 32 40 48 56 13 26 39 52 65 78 91 20 40 60 80 100 120 140 # # 0 0 1 1 2 2 2 2 3 3 3 3 # # 0 0 1 1 2 # 0 0 1 2 3 4 2 2 2 3 3 3 3 2 3 3 4 4 5 5 # # 0 0 1 1 2 # 0 0 1 2 3 4 # 0 1 2 3 4 6 2 2 2 3 3 3 3 2 3 3 4 4 5 5 3 4 4 5 6 6 7 # # 0 0 1 1 2 # 0 0 1 2 3 4 # 0 1 2 3 4 6 # 1 2 3 5 7 9 2 2 2 3 3 3 3 2 3 3 4 4 5 5 3 4 4 5 6 6 7 4 5 6 7 8 9 10 # 2 # 2 0 2 0 3 1 3 1 3 2 3 # 2 0 3 0 3 1 4 2 4 3 5 4 5 # 3 0 4 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 2 7 4 9 6 11 9 12 12 14 14 15 # 2 # 2 0 2 0 3 1 3 1 3 2 3 # 2 0 3 0 3 1 4 2 4 3 5 4 5 # 3 0 4 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 2 7 4 9 6 11 9 12 12 14 14 15 0 6 3 9 7 12 10 15 14 17 18 20 21 22 ++ # 2 0 3 0 3 1 4 2 4 3 5 4 5 # 3 0 3 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 2 7 4 9 6 11 9 12 12 14 14 15 0 6 3 9 7 12 10 15 14 17 18 20 21 22 1 8 6 12 11 17 16 22 22 25 27 29 32 33 ++ ++ # 3 0 3 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 2 7 4 9 6 11 9 12 12 14 14 15 0 6 3 9 7 12 10 15 14 17 18 20 21 22 1 8 6 12 11 17 16 22 22 25 27 29 32 33 ++ ++ # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 2 7 4 9 6 11 9 12 12 14 14 15 0 6 3 9 7 12 10 15 14 17 18 20 21 22 1 8 6 12 11 17 16 22 22 25 27 29 32 33 = Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection. = Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available). Ac = Acceptance number. ++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available). # = Acceptance not permitted at this sample size. ++ ++ 0 4 2 7 4 9 6 11 9 12 12 14 14 15 0 6 3 9 7 12 10 15 14 17 18 20 21 22 1 8 6 12 11 17 16 22 22 25 27 29 32 33 ++ ++ 0 6 3 9 7 12 10 15 14 17 18 20 21 22 1 8 6 12 11 17 16 22 22 25 27 29 32 33 ++ ++ 1 8 6 12 11 17 16 22 22 25 27 29 32 33 3 10 10 17 17 24 24 31 32 37 40 43 48 49 ++ ++ 3 10 10 17 17 24 24 31 32 37 40 43 48 49 6 15 16 25 26 36 37 46 49 55 61 64 72 73 ++ ++ 6 15 16 25 26 36 37 46 49 55 61 64 72 73 ++ ++ ++ = Use first sampling plan above arrow. Re = Rejection number. 10
  • 14. Table IV - B. (continued). Acceptable Quality Levels (tightened inspection) Sample Cumula size Sample tive 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000 Sample code size sample letter size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re K L M N P Q R S First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh 32 32 32 32 32 32 32 50 50 50 50 50 50 50 80 80 80 80 80 80 80 125 125 125 125 125 125 125 200 200 200 200 200 200 200 315 315 315 315 315 315 315 500 500 500 500 500 500 500 800 800 800 800 800 800 800 32 64 96 128 160 192 224 50 100 150 200 250 300 350 80 160 240 320 400 480 560 125 250 375 500 625 750 875 200 400 600 800 1000 1200 1400 315 630 945 1260 1575 1890 2205 500 1000 1500 2000 2500 3000 3500 800 1600 2400 3200 4000 4800 5600 # # 0 0 1 1 2 # # 0 0 1 1 2 2 2 2 3 3 3 3 # # 0 0 1 1 2 # 0 0 1 2 3 4 2 2 2 3 3 3 3 2 3 3 4 4 5 5 # # 0 0 1 1 2 # 0 0 1 2 3 4 # 0 1 2 3 4 6 2 2 2 3 3 3 3 2 3 3 4 4 5 5 3 4 4 5 6 6 7 # 2 # 2 0 2 0 3 1 3 1 3 2 3 # 2 0 3 0 3 1 4 2 4 3 5 4 5 # 3 0 4 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 # 2 # 2 0 2 0 3 1 3 1 3 2 3 # 2 0 3 0 3 1 4 2 4 3 5 4 5 # 3 0 4 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 2 7 4 9 6 11 9 12 12 14 14 15 # 2 # 2 0 2 0 3 1 3 1 3 2 3 # 2 0 3 0 3 1 4 2 4 3 5 4 5 # 3 0 4 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 2 7 4 9 6 11 9 12 12 14 14 15 0 6 3 9 7 12 10 15 14 17 18 20 21 22 # 2 # 2 0 2 0 3 1 3 1 3 2 3 # 2 0 3 0 3 1 4 2 4 3 5 4 5 # 3 0 4 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 2 7 4 9 6 11 9 12 12 14 14 15 0 6 3 9 7 12 10 15 14 17 18 20 21 22 1 8 6 12 11 17 16 22 22 25 27 29 32 33 # 2 0 3 0 3 1 4 2 4 3 5 4 5 # 3 0 4 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 2 7 4 9 6 11 9 12 12 14 14 15 0 6 3 9 7 12 10 15 14 17 18 20 21 22 1 8 6 12 11 17 16 22 22 25 27 29 32 33 # 3 0 4 1 4 2 5 3 6 4 6 6 7 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 2 7 4 9 6 11 9 12 12 14 14 15 0 6 3 9 7 12 10 15 14 17 18 20 21 22 1 8 6 12 11 17 16 22 22 25 27 29 32 33 # 4 1 5 2 6 3 7 5 8 7 9 9 10 0 4 2 7 4 9 6 11 9 12 12 14 14 15 0 6 3 9 7 12 10 15 14 17 18 20 21 22 1 8 6 12 11 17 16 22 22 25 27 29 32 33 0 2 4 6 9 12 14 0 3 7 10 14 18 21 1 6 11 16 22 27 32 4 7 9 11 12 14 15 6 9 12 15 17 20 22 8 12 17 22 25 29 33 0 3 7 10 14 18 21 1 6 11 16 22 27 32 6 9 12 15 17 20 22 8 12 17 22 25 29 33 1 6 11 16 22 27 32 8 12 17 22 25 29 33 2 2 2 3 3 3 3 11
  • 15. Table IV - C. Multiple Sampling Plans for Reduced Inspection (Master Table). Acceptable Quality Levels (reduced inspection) Sample Cumula size Sample tive Sample 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000 code size sample letter size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re A B C D E ++ ++ ++ F First Second Third Fourth Fifth Sixth Seventh 2 2 2 2 2 2 2 2 4 6 8 10 12 14 G First Second Third Fourth Fifth Sixth Seventh 3 3 3 3 3 3 3 3 6 9 12 15 18 21 H First Second Third Fourth Fifth Sixth Seventh 5 5 5 5 5 5 5 5 10 15 20 25 30 35 J First Second Third Fourth Fifth Sixth Seventh 8 8 8 8 8 8 8 8 16 24 32 40 48 56 K First Second Third Fourth Fifth Sixth Seventh 13 13 13 13 13 13 13 13 26 39 52 65 78 91 ++ ++ ++ ++ # # 0 0 0 0 1 2 2 2 3 3 3 3 # # 0 0 0 1 1 2 3 3 4 4 5 5 # # 0 0 1 1 2 3 3 4 5 6 6 7 # 0 0 1 2 3 4 3 4 5 6 7 7 8 # 4 0 5 1 6 2 7 3 8 4 9 6 10 # # 0 0 0 0 1 2 2 2 3 3 3 3 # # 0 0 0 1 1 2 3 3 4 4 5 5 # # 0 0 1 1 2 3 3 4 5 6 6 7 # 0 0 1 2 3 4 3 4 5 6 7 7 8 # 4 0 5 1 6 2 7 3 8 4 9 6 10 # # 0 0 0 0 1 2 2 2 3 3 3 3 # # 0 0 0 1 1 2 3 3 4 4 5 5 # # 0 0 1 1 2 3 3 4 5 6 6 7 # 0 0 1 2 3 4 3 4 5 6 7 7 8 # 4 0 5 1 6 2 7 3 8 4 9 6 10 # # 0 0 0 0 1 # # 0 0 0 0 1 2 2 2 3 3 3 3 2 2 2 3 3 3 3 # # 0 0 0 1 1 2 3 3 4 4 5 5 # # 0 0 1 1 2 3 3 4 5 6 6 7 # 0 0 1 2 3 4 # # 0 0 0 1 1 2 3 3 4 4 5 5 # # 0 0 1 1 2 3 3 4 5 6 6 7 # 0 0 1 2 3 4 3 4 5 6 7 7 8 # 4 0 5 1 6 2 7 3 8 4 9 6 10 # 1 2 3 5 7 9 # 1 2 3 5 7 9 # 1 2 3 5 7 9 3 4 5 6 7 7 8 ++ ++ # 4 0 5 1 6 2 7 3 8 4 9 6 10 # 1 2 3 5 7 9 # 1 2 3 5 7 9 ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ 4 0 5 0 6 6 1 7 3 9 8 3 9 6 12 10 5 12 8 15 11 7 13 11 17 12 10 15 14 20 14 13 17 18 22 4 0 5 0 6 6 1 7 3 9 8 3 9 6 12 10 5 12 8 15 11 7 13 11 17 12 10 15 14 20 14 13 17 18 22 4 0 5 0 6 6 1 7 3 9 8 3 9 6 12 10 5 12 8 15 11 7 13 11 17 12 10 15 14 20 14 13 17 18 22 4 0 5 0 6 6 1 7 3 9 8 3 9 6 12 10 5 12 8 15 11 7 13 11 17 12 10 15 14 20 14 13 17 18 22 4 0 5 0 6 6 1 7 3 9 8 3 9 6 12 10 5 12 8 15 11 7 13 11 17 12 10 15 14 20 14 13 17 18 22 = Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection. = Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available). Ac = Acceptance number. ++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available). # = Acceptance not permitted at this sample size. = If, after the final sample, the acceptance number has been exceeded but the rejection number has not been reached, accept the lot but reinstate normal inspection. = Use first sampling plan above arrow. Re = Rejection number. 12
  • 16. Table IV - C. (continued). Acceptable Quality Levels (reduced inspection) Sample Cumula size Sample tive 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000 Sample code size sample letter size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re L M N P Q R First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh First Second Third Fourth Fifth Sixth Seventh 20 20 20 20 20 20 20 32 32 32 32 32 32 32 50 50 50 50 50 50 50 80 80 80 80 80 80 80 125 125 125 125 125 125 125 200 200 200 200 200 200 200 20 40 60 80 100 120 140 32 64 96 128 160 192 224 50 100 150 200 250 300 350 80 160 240 320 400 480 560 125 250 375 500 625 750 875 200 400 600 800 1000 1200 1400 # # 0 0 0 0 1 2 2 2 3 3 3 3 # # 0 0 0 0 1 # # 0 0 0 1 1 2 2 2 3 3 3 3 2 3 3 4 4 5 5 # # 0 0 0 0 1 # # 0 0 0 1 1 # # 0 0 1 1 2 2 2 2 3 3 3 3 2 3 3 4 4 5 5 3 3 4 5 6 6 7 # # 0 0 0 0 1 # # 0 0 0 1 1 # # 0 0 1 1 2 # 0 0 1 2 3 4 2 2 2 3 3 3 3 2 3 3 4 4 5 5 3 3 4 5 6 6 7 3 4 5 6 7 7 8 # # 0 0 0 0 1 # # 0 0 0 1 1 # # 0 0 1 1 2 # 0 0 1 2 3 4 # 0 1 2 3 4 6 2 2 2 3 3 3 3 2 3 3 4 4 5 5 3 3 4 5 6 6 7 3 4 5 6 7 7 8 4 5 6 7 8 9 10 # # 0 0 0 0 1 # # 0 0 0 1 1 # # 0 0 1 1 2 # 0 0 1 2 3 4 # 0 1 2 3 4 6 # 1 2 3 5 7 9 2 2 2 3 3 3 3 2 3 3 4 4 5 5 3 3 4 5 6 6 7 3 4 5 6 7 7 8 4 5 6 7 8 9 10 4 6 8 10 11 12 14 # 2 # 3 0 3 0 4 0 4 1 5 1 5 # 3 # 3 0 4 0 5 1 6 1 6 2 7 # 3 0 4 0 5 1 6 2 7 3 7 4 8 # 4 0 5 1 6 2 7 3 8 4 9 6 10 # 4 1 6 2 8 3 10 5 11 7 12 9 14 0 5 1 7 3 9 5 12 7 13 10 15 13 17 # 3 # 3 0 4 0 5 1 6 1 6 2 7 # 3 0 4 0 5 1 6 2 7 3 7 4 8 # 4 0 5 1 6 2 7 3 8 4 9 6 10 # 4 1 6 2 8 3 10 5 11 7 12 9 14 0 5 1 7 3 9 5 12 7 13 10 15 13 17 0 6 3 9 6 12 8 15 11 17 14 20 18 22 # 3 0 4 0 5 1 6 2 7 3 7 4 8 # 4 0 5 1 6 2 7 3 8 4 9 6 10 # 4 1 6 2 8 3 10 5 11 7 12 9 14 0 5 1 7 3 9 5 12 7 13 10 15 13 17 0 6 3 9 6 12 8 15 11 17 14 20 18 22 # 4 0 5 1 6 2 7 3 8 4 9 6 10 # 4 1 6 2 8 3 10 5 11 7 12 9 14 0 5 1 7 3 9 5 12 7 13 10 15 13 17 0 6 3 9 6 12 8 15 11 17 14 20 18 22 # 1 2 3 5 7 9 0 1 3 5 7 10 13 0 3 6 8 11 14 18 4 6 8 10 11 12 14 5 7 9 12 13 15 17 6 9 12 15 17 20 22 0 1 3 5 7 10 13 0 3 6 8 11 14 18 5 0 6 7 3 9 9 6 12 12 8 15 13 11 17 15 14 20 17 18 22 6 9 12 15 17 20 22 = Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection. = Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available). Ac = Acceptance number. ++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available). # = Acceptance not permitted at this sample size. = If, after the final sample, the acceptance number has been exceeded but the rejection number has not been reached, accept the lot but reinstate normal inspection. = Use first sampling plan above arrow. Re = Rejection number. 13
  • 17. Table V-A. Average Outgoing Quality Limit Factors for Normal Inspection (Single Sampling) * Code Sample Letter size A H J 80 K 125 65 100 150 250 400 650 1000 42 69 97 160 220 330 470 730 1100 28 46 65 110 150 220 310 490 720 1100 17 27 39 63 90 130 190 290 430 660 11 17 24 40 56 82 120 180 270 410 6.5 11 15 24 34 50 72 110 170 250 4.2 6.9 9.7 16 22 33 47 73 2.6 4.3 6.1 9.9 14 21 29 46 1.7 2.7 3.9 6.3 9.0 13 19 29 1.7 2.4 4.0 5.6 8.2 12 18 0.67 50 40 1.1 32 25 1.1 1.6 2.5 3.6 5.2 7.5 12 7.3 20 G 0.40 0.65 13 F 0.25 1.0 8 E 0.15 1.5 5 D 0.10 2.5 3 C 0.010 0.015 0.025 0.040 0.065 4.0 2 B Acceptable Quality Level L 1250 R 2000 4.6 2.8 1.8 1.2 0.74 0.46 0.29 800 Q 7.4 500 P 12 315 N 10 15 18 200 M 6.5 0.42 0.69 0.97 1.6 2.2 3.3 4.7 0.27 0.44 0.62 1.00 1.4 2.1 3.0 4.7 2.9 0.18 0.12 0.074 0.17 0.27 0.39 0.63 0.90 1.3 1.9 0.11 0.17 0.24 0.40 0.56 0.82 1.2 1.8 0.11 0.16 0.25 0.36 0.52 0.75 1.2 0.042 0.069 0.097 0.16 0.22 0.33 0.47 0.73 0.046 0.029 0.067 * Note: For the exact AOQL, the above volume must be multiplied by 1 Sample size Lot or Batch size 14
  • 18. Table V-B. Average Outgoing Quality Limit Factors for Tightened Inspection (Single Sampling) * Code Sample Letter size A H 50 J 80 K 125 1.0 1.5 2.5 4.0 6.5 40 65 100 150 250 400 650 1000 42 32 0.65 20 G 0.40 13 F 0.25 8 E 0.15 5 D 0.10 69 97 160 260 400 620 970 28 46 65 110 170 270 410 650 1100 17 27 39 63 100 160 250 390 610 11 3 C 0.010 0.015 0.025 0.040 0.065 10 15 25 17 24 40 64 99 160 240 380 11 15 24 40 61 95 150 240 62 2 B Acceptable Quality Level L 2000 S 3150 4.2 6.9 9.7 16 26 40 2.6 4.3 6.1 9.9 16 25 39 1.7 2.7 3.9 6.3 16 25 1.1 1.7 2.4 4.0 6.4 9.9 0.67 1.1 1.6 2.5 4.1 6.4 9.9 6.2 1.2 0.74 0.46 0.29 1250 R 6.5 1.8 800 Q 2.8 500 P 4.6 315 N 7.4 200 M 12 0.18 0.42 0.074 0.69 0.97 1.6 2.6 4.0 0.27 0.12 0.44 0.62 1.0 1.6 2.5 2.5 0.17 0.27 0.39 0.63 1.0 1.6 0.17 0.24 0.40 0.64 0.99 1.6 0.11 0.16 0.25 0.41 0.64 0.99 0.042 0.069 0.097 0.16 0.26 0.40 0.62 0.067 0.018 16 3.9 0.11 0.046 0.029 10 0.027 * Note: For the exact AOQL, the above volume must be multiplied by 1 Sample size Lot or Batch size 15
  • 19. Table VIII. Limit Numbers for Reduced Inspection. Number of sample units from last 10 lots or batches Acceptable Quality Level 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000 115 178 301 181 277 20 - 29 30 - 49 50 - 79 ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ 0 ∙ 0 0 0 0 2 0 1 3 2 3 7 4 7 14 8 13 25 14 22 40 22 36 63 40 63 110 68 105 181 80 - 129 130 - 199 200 - 319 ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ 0 ∙ 0 0 0 0 2 0 2 4 2 4 8 4 7 14 7 13 22 14 25 40 24 42 68 42 72 115 68 115 181 105 177 277 181 301 471 297 490 320 - 499 500 - 799 800 - 1249 ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ 0 ∙ 0 0 0 0 2 0 2 4 1 3 7 4 7 14 8 14 24 14 25 42 24 40 68 39 63 105 68 110 181 113 181 189 1250 - 1999 2000 - 3149 3150 - 4999 ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ 0 ∙ 0 0 0 0 1 0 2 4 2 4 8 4 8 14 7 14 24 13 22 38 24 40 67 40 68 111 69 115 186 110 181 169 5000 - 7999 8000 - 12499 12500 - 19999 ∙ ∙ ∙ ∙ ∙ 0 ∙ 0 0 0 0 2 0 2 4 2 4 7 3 7 13 7 14 24 14 24 40 25 42 69 40 68 110 63 105 169 110 181 181 20000 - 31499 31500 - 49999 50000 & over 0 0 2 0 1 3 2 4 7 4 8 14 8 14 25 14 24 40 22 38 63 40 67 110 68 111 181 115 186 301 181 ∙ Denotes that the number of sample units from the last ten lots or batches is not sufficient for reduced inspection for this AQL. In this instance more than ten lots or batches may be used for the calculation, provided that the lots or batches used are the most recent ones in sequence, that they have all been on normal inspection, and that none has been rejected while on original inspection. 16