SlideShare a Scribd company logo
1 of 13
Download to read offline
Smart Grid and Renewable Energy, 2018, 9, 113-125
http://www.scirp.org/journal/sgre
ISSN Online: 2151-4844
ISSN Print: 2151-481X
DOI: 10.4236/sgre.2018.97008 Jul. 30, 2018 113 Smart Grid and Renewable Energy
Experimental Study of Environmental Impact
on the Efficiency of a House-Hold PV Panel
Yassir Idris Abdalla Osman1,2,3, Jinping Li1,2,3*, Xiaofei Zhen1,2,3
1
Western China Energy & Environment Research Center, Lanzhou University of Technology, Lanzhou, China
2
Gansu Key Laboratory of Complementary Energy System of Biomass and Solar Energy, Lanzhou, China
3
China Northwestern Collaborative Innovation Center of Key Technology for Northwest Low
Carbon Urbanization, Lanzhou, China
Abstract
House-hold PV panels are widely used; however, their performance is signif-
icantly degraded under real operating conditions. Environmental factors such
as ambient temperature, wind speed, and solar irradiance has a major impact
on the house-hold PV panel efficiency. In this paper an experimental study
was conducted during the winter period in a single building in Minqin coun-
ty, Gansu province, China. The experimental measurements were used to
quantify the house-hold PV panel performance and operating characteristics.
Based on the experimental results the house-hold PV panel performance is
basically affected by the PV surface temperature, therefore, multilevel of
energy is detected. Approximately 3% efficiency variation is detected due to
the impact of the environmental factors.
Keywords
House-Hold PV Panel, Environmental Factors, Photovoltaic Efficiency
1. Introduction
Among all the available electricity sources, solar photovoltaic (PV) is the most
popular for installation [1]. PV technology witnessed a significant reduction in
the cost and appreciable progress in increasing the efficiency [2] [3]. Generally,
the standard test conditions are considered in most cases to address the PV per-
formance specification, however, there is a considerable variation when the ac-
tual conditions are adopted.
A part of the irradiance received by the PV panel is transformed into electric-
ity, and the other is transformed into heat losses which is responsible for reduc-
How to cite this paper: Osman, Y.I.A., Li,
J.P. and Zhen, X.F. (2018) Experimental
Study of Environmental Impact on the
Efficiency of a House-Hold PV Panel. Smart
Grid and Renewable Energy, 9, 113-125.
https://doi.org/10.4236/sgre.2018.97008
Received: July 7, 2018
Accepted: July 27, 2018
Published: July 30, 2018
Copyright ยฉ 2018 by authors and
Scientific Research Publishing Inc.
This work is licensed under the Creative
Commons Attribution International
License (CC BY 4.0).
http://creativecommons.org/licenses/by/4.0/
Open Access
Y. I. A. Osman et al.
DOI: 10.4236/sgre.2018.97008 114 Smart Grid and Renewable Energy
ing the PV panel efficiency [4] [5]. Altitude and azimuth play a crucial role in
determination of sun position during the day [6]. It is evidence that the maxi-
mum reception of solar radiation occurs when the PV panel is perpendicular to
the sun radiation [7] [8]. Many publications accounting 0.08% of loss takes place
when the location of the PV panel is diverged from the south particularly in
azimuth angle [9]. Basically, the PV panel output power is directly proportion to
the solar radiation [10]. Due to the approximate linearity the PV current is in-
creased in accordance with the increment of the solar radiation [11] [12] [13].
Regarding this approximate linearity, the influence of the solar irradiance on the
PV output current is hard to enumerate [14] [15].
In order to address the influence of ambient temperature on the PV panel
functionality, two parameters exist short circuit current sc
I and open circuit
volts oc
V . When the PV module temperature is increasing, the short circuit
witnessed an insignificant increase (ranged between 0.04 and 0.09%/K), in con-
trast to open circuit voltage, it suffers a considerable degradation (up to
โˆ’0.45%/K for crystalline silicon) [16] [17]. The efficiency of the PV panel is va-
ried according to the PV type under consideration. In the body of literature, it
was reported that when the ambient temperature increased by 1หšC, the efficiency
is reduced within the range of 0.35% - 0.8% [18] [19] [20] [21]. An experimental
work concerns the effects of temperature coefficient on several silicon-based PV
types, which reveals a loss of 3% - 5% occur as a result of 10หšC variation [22].
Some publications addressed the influence of ambient temperature on the PV
panel performance considering geographical localization. Within the context,
the Crystalline PV panel showed a reduction of 0.45% when the temperature
rises 1หšC in [23] and 0.5 in [24]. For materials such as amorphous silicon, cad-
mium Telluride and copper-indium-gallium-diselenide which are used in thin
film PV panels, the performance degradation falls in the range of 0.21% - 0.36%
[25] [26] [27] [28]. Generally, the increment in the ambient temperature is cor-
related with performance degradation, and this fact is revealed in [29] [30]. By
considering a water-based cooling technique, the PV surface temperature wit-
ness a reduction ranged 5หšC to 23หšC which enhance the performance from 0 %
to 22% [31].
Many researchers have proposed different approaches regarding the influence
of wind on the PV module temperature. Wind has the ability of cooling the PV
module within the range of 15หšC - 20หšC when the wind speed is 10 m/s under
1000 W/m2
of solar irradiance [32]. A considerable variation on the PV panel
operation characteristic is detected due to the high dynamic nature of the Wind
[29] [33]. In highly dynamic wind regions, the PV panel performance reaches up
to 18%, according to the experimental results in [34]. However, the influence of
the wind speed on the PV panel performance is quietly trivial in contrast to the
ambient temperature and solar irradiance. A method known as in-situ is consi-
dered in order to examine the experimental data and for validation purpose. One
drawback associated with this method is that, the experimental data need to be
Y. I. A. Osman et al.
DOI: 10.4236/sgre.2018.97008 115 Smart Grid and Renewable Energy
substituted by numerical weather prediction [35] [36].
Generally, the house-hold PV panel is affected by numerous environmental
factors such as seasonal variation, humidity, rainfall, positioning, etc. However,
the influences of these factors are not considered in this investigation.
Regarding the unique weather conditions of Minqin County, the house-hold
PV panel performance is expected to vary in many aspects. Accordingly, the
main objective of this work is to quantify the performance of the house-hold PV
panel and reveal the operating characteristics as well based on the experimental
results.
A house-hold PV panel system was built and tested as well. The environmen-
tal factors are measured and recorded through the data acquisition equipment.
The experimental results are extensively analyzed and discussed.
2. Photovoltaic Surface Temperature Theory
The relationship regarding the ambient temperature (Ta) and the photovoltaic
surface temperature (Tpv) is nearly linear. Basically, the variation of (Tpv) and
(Ta) is a function of solar irradiance, and this result is associated with the effect
of wind speed. The parameter (Tpv) is a function of (Ta) insignificantly influ-
enced by solar irradiance (G) and wind speed (v). By taking into account the
standard values for beta coefficients 0.74, 0.33, and โˆ’0.11 respectively, the cor-
responding linear correlation is obtained [37].
( ) ( ) ( )
( ) ( )
2
2.08 0.13 1.038 0.004 0.0182 0.0001
1.13 0.02 0.96
pv a
T T G
v R
= ยฑ + ยฑ โ‹… + ยฑ โ‹…
โˆ’ ยฑ โ‹… =
(1)
The most common expression addressed the PV module temperature is given
in Equation (2)
( )
( )
,
1
pv a NOCT a NOCT
NOCT
T T T T
G
=
+ โ‹… โˆ’ (2)
where NOCT
T is the temperature at nominal operating cell temperature ( ( )
NOCT
G
= 800 W/m2
, Ta = 20หšC, v = 1 m/s), NOCT
T is varying according to the PV tech-
nology a typical value for NOCT
T is 45หšC. According to the literature, the typical
PV operating temperature is at 45หšC, the best at 33หšC and the worst at 58หšC [38].
This expression does not consider the wind cooling influence.
A compact PV temperature expression is given by:
0.035
pv a
T T G
=+ โ‹… (3)
In order to consider wind speed factor, the following expression can be used:
0.032
8.91 2
pv a
T T G
v
=
+ โ‹…
+ โ‹…
(4)
3. PV Efficiency Theory
The efficiency of the PV panel is positively influenced by wind speed. However,
this influence is not vital. Within the body of literature, it is reported that, the
Y. I. A. Osman et al.
DOI: 10.4236/sgre.2018.97008 116 Smart Grid and Renewable Energy
wind speed influence varies between 1.3 and 1.65 m/s [28] [29] [30] [31] [32].
However, regarding the high dynamic nature of wind factor, it is quite difficult
to be quantified. The factor that has a vital influence on the PV efficiency is the
pv
T . By associating these values 0.85, โˆ’0.39, and 0.32 respectively, for standard
beta coefficient, the following linear correlation is obtained to address the actual
PV efficiency (ฮท%)
( ) ( ) ( )
( ) ( )( )
2
6.2 0.2 0.0312 0.0004 0.176 0.007
4.2 0.2 0.53
pv
T AM
R
ฯ„
ฮท
ฮฑ ฮธ
ยฑ
= โ‹… ยฑ โˆ’ โ‹… ยฑ โ‹… โˆ’ โ‹…
+ ยฑ โ‹… =
(5)
where ฮฑ and ฯ„ are absorptance and transmittance respectively. AM is the air
mass (1.6) [39], and ฮธ is the solar zenith angle.
Another expression that associates the actual operating condition and the
standard test condition (STC) is given by:
( ) ( ) ( )
( ) ( )( )
2
1.7 0.2 0.631 0.008 0.176 0.007
4.2 0.2 0.53
k AM
R
ฮท ฮท
ฯ„ฮฑ ฮธ
=
โˆ’ ยฑ + ยฑ โ‹… โˆ’ ยฑ โ‹…
+ ยฑ โ‹… =
(6)
where k
ฮท is efficiency under specific STC conditions.
Based on Equation (5) and Equation (6) the actual efficiency is addressed as:
( ) ( ) ( ) ( )
( ) ( ) ( )( )
2 4 2
,
2
7.8 0.2 3.74 0.07 10 10 0.8 0.3 10
0.197
3.2
0.008 2.6 0.2
0.
0.51
2
a x
T G v
AM R
ฮท
ฯ„ฮฑ ฮธ
โˆ’ โˆ’ โˆ’
= ยฑ โˆ’ ยฑ โ‹… โ‹… โ‹… โ‹… + ยฑ โ‹… โ‹…
โˆ’ ยฑ โ‹… โ‹… =
โˆ’
ยฑ
ยฑ
+
(7)
The amount of average deviation when Equation (7) is considered to calculate
the photovoltaic efficiency is about 2% of the actual measured efficiency. It is
evidence that Equation (7) can be used to predict the photovoltaic efficiency re-
gardless region variation, environmental factors and season variation [37].
4. Experimental Setup
This experiment is conducted in a single building in Minqin county. The lowest
average solar radiation on the tilted surface of the local altitude is 13 MJ/m2
while the peak solar irradiance is 15 MJ/m2
.
The PV panels are fabricated by Xinsheng PV Technology Co. Ltd. A total of
10 monocrystalline silicon PV is utilized. The PV specifications are listed in Ta-
ble 1. The overall DC of the batteries group is 24 V, the inverter efficiency is
80%, and the battery depth is 60%.
The list of the experimental instruments is presented in Table 2 followed by
the schematic of the experiment setup Figure 1.
5. Experimental Analysis
For this experiment the following factors are considered and quantified, the
wind speed (v, m/s2
), solar irradiance (G, W/m2
), ambient temperature (Ta, หšC),
photovoltaic surface temperature (Tpv, หšC). This experiment is conducted over
one week started at 9 Feb. 2015 and ended on 15 Feb. 2015. The process of col-
lecting data extended from 0800 oโ€™clock to 1900 oโ€™clock, each day 8286
Y. I. A. Osman et al.
DOI: 10.4236/sgre.2018.97008 117 Smart Grid and Renewable Energy
Table 1. PV panel specification.
Peak Power (Pmax) 100 w
Voltage at Pmax 18 V
Current at Pmax 5.55 A
Current at Pmax 21.6 V
Open circuit voltage 21.6 V
Short circuit current 5.95 A
Size 1200*540*30 mm
Weight 9.0 KGS
Table 2. The experimental instruments.
Parameters Device model Specifications Manufacturer
Wind speed
YGC-FS
Wind speed sensor
Range: 0 - 45 m
Accuracy: ยฑ(0.3 + 0.03 V)
Resolving power: 0.1 m/s
Wuhan Yi Valley Science
and technology
Company Limited
Temperature
PT 100
Temperature sensor
Range: โˆ’50หšC - 100หšC
Accuracy: ยฑ1หšC
Beijing science and
technology Saiyiling
Limited company
Photovoltaic array
output voltage
CJ-DA61-D
DC voltmeter
Range: 0 - 50 V
Precision: 0.5 s
Shanghai Chu Jing electric
Limited company
Photovoltaic array
Output current
CJ-DA61-D
DC ammeter
Range: 0 - 25 Ah
Accuracy: 0.5 s
Shanghai Chu Jing electric
Limited company
Data acquisition
instrument
34972A
Agilent Technology
Limited company
Solar irradiance
CG-07 Solar
Radiometer
Sensitivity: 7 - 14
mv/kWโˆ™mโˆ’2
Range: 0.3 - 3.2 ฮผm
Handan Development
Zone Qing Yi Electronic
Technology Co., Ltd.
Figure 1. Schematic diagram of the experiment setup.
measurements are recorded. Figure 2(a) presents the temperature for the entire
week, and boxplot is adopted to present the measurements. Measurement
ranged 1st
to 3rd
quartile is included within the box and the difference is known
as the interquartile range (IQR). The minimum and the maximum are presented
by whiskers below and above the rectangular respectively. Measurements that are
three times or greater than the 3rd
quartile or three times the inter quartile range or
lower than the 1st
quartile are designated outlier and plotted as red plus signs.
PV Panel
Inverter
Data logger
~ =
Ambient temperature (Ta, OC)
Wind speed (v, m/s2)
Solar radiation (G, W/m2)
Control
board
Y. I. A. Osman et al.
DOI: 10.4236/sgre.2018.97008 118 Smart Grid and Renewable Energy
(a)
(b)
(c)
Figure 2. Statistical plots of the experimental measurements of (9 Feb. 2015-15 Feb.
2015). (a) Ambient temperature; (b) Wind speed; (c) Solar irradiance.
-14
-12
-10
-8
-6
-4
-2
0
2
4
6
1 2 3 4 5 6 7
D a y s
A
m
b
i
e
n
t
T
e
m
p
e
r
a
t
u
r
e
0
5
10
15
20
25
30
1 2 3 4 5 6 7
D a y s
W
i
n
d
s
p
e
e
d
0
100
200
300
400
500
600
700
800
900
1000
1 2 3 4 5 6 7
D a y s
S
o
l
a
r
i
r
r
a
d
i
a
n
c
e
Y. I. A. Osman et al.
DOI: 10.4236/sgre.2018.97008 119 Smart Grid and Renewable Energy
Figure 2(a) reveals that the minimum ambient temperature is โˆ’14.6หšC detected
on the 6th
day, the maximum temperature is 5.9หšC detected in the 7th
, while the
maximum mean is 1.31หšC detected in the 7th
. The outliers only detected in the 3th
and 5th
days where the temperature falls below โˆ’13.2หšC and โˆ’10.7หšC respective-
ly. According to the measurements the temperature is less than 16หšC a day. Fig-
ure 2(b) shows the record of the wind speed data per day for the same week. A
significant variation is shown by the wind speed and described by several out-
liers. The minimum wind speed is 0.18 m/s detected on the 3th
day, the maxi-
mum wind speed is 32.97 m/s is detected on the 7th
day, and the maximum mean
is 4.99 m/s detected on the 7th
day. Generally, the wind variation is lower than 33
m/s. The solar irradiance measurements are shown in Figure 2(c) for the same
period. The outliers are only detected on the 2nd
day when the solar radiation is
exceeding 800 W/m2
. The minimum solar irradiance is โˆ’3.8 W/m2
witnessed on
the 1st
day, the maximum solar irradiance is 1040 measured on the 5th
day, and
the maximum mean is 536.3 W/m2
recorded on the 1st
day. The variation of solar
irradiance during the experiment is more than 800 W/m2
per day.
In Figure 3 the (Tpv) and (Ta) are depicted as a function of the day hours for
all measurements of the week. These figures reveal the dependence of PV surface
temperature on the solar irradiance.
What is interesting about the data in Table 3 is that at 0800 and 1900 0โ€™clock
in some days the (Tpv) measurements are lower than (Ta). This is mainly due to
the influence of wind.
Based on the experimental results, as shown in Figure 4 the minimum effi-
ciency is 11.52% achieved during the 5th
day where the wind speed is ranged be-
tween 1.19 m/s and 5.97 m/s; the minimum and maximum ambient temperature
is โˆ’10.7หšC and โˆ’0.67หšC respectively; the mean of ambient temperature is
โˆ’4.2หšC; the solar irradiance is ranged (โˆ’2.80 - 408.4) W/m2
.
The maximum efficiency being 14.75% is detected during the 1st
day where the
wind speed is ranged between (0.2 - 3.75) m/s; the ambient temperature is
ranged between (โˆ’12.9 - 4.03); the solar irradiance is ranged between (โˆ’3.84 -
994) W/m2
. Generally, when the solar irradiance witnesses a significant increase,
the instantaneous value of the efficiency is reduced, particularly, when the solar
(a)
6 8 10 12 14 16 18 20
-20
0
20
40
60
T i m e ( h )
T
e
m
p
e
r
a
t
u
r
e
o
C
6 8 10 12 14 16 18 20
11
12
13
14
15
E
f
f
i
c
i
e
n
c
y
Ambient
Pv Temp
Efficienc
Y. I. A. Osman et al.
DOI: 10.4236/sgre.2018.97008 120 Smart Grid and Renewable Energy
(b) (c)
(d) (e)
(f) (g)
Figure 3. Ambient temperature, PV surface temperature, and the efficiency as a function of day hours for the entire week. (a) 1st
day; (b) 2nd
day; (c) 3rd
day; (d) 4th
day; (e) 5th
day; (f) 6th
day.
irradiance exceeds 800 W/m2
, this due to the considerable increase of the pho-
tovoltaic surface temperature as shown in Figure 5.
6. Conclusions
In this paper the influences of the environmental factors such as solar radiation,
wind speed, and ambient temperature on the house-hold PV panel efficiency are
6 8 10 12 14 16 18 20
-20
0
20
40
T i m e ( h )
T
e
m
p
e
r
a
t
u
r
e
o
C
6 8 10 12 14 16 18 20
12
13
14
15
E
f
f
i
c
i
e
n
c
y
Ambient
Pv Temp
Efficienc
6 8 10 12 14 16 18 20
-20
0
20
40
T i m e ( h )
T
e
m
p
e
r
a
t
u
r
e
o
C
6 8 10 12 14 16 18 20
10
12
14
16
E
f
f
i
c
i
e
n
c
y
Ambient
Pv Temp
Efficienc
6 8 10 12 14 16 18 20
-20
0
20
40
T i m e ( h )
T
e
m
p
e
r
a
t
u
r
e
o
C
6 8 10 12 14 16 18 20
12
13
14
15
E
f
f
i
c
i
e
n
c
y
Ambient
Pv Temp
Efficienc
6 8 10 12 14 16 18 20
-20
0
20
40
60
T i m e ( h )
T
e
m
p
e
r
a
t
u
r
e
o
C
6 8 10 12 14 16 18 20
11
12
13
14
15
E
f
f
i
c
i
e
n
c
y
Ambient
Pv Temp
Efficienc
6 8 10 12 14 16 18 20
-20
0
20
40
T i m e ( h )
T
e
m
p
e
r
a
t
u
r
e
o
C
6 8 10 12 14 16 18 20
10
12
14
16
E
f
f
i
c
i
e
n
c
y
Ambient
Pv Temp
Efficiency
6 8 10 12 14 16 18 20
-10
0
10
20
30
40
T i m e ( h )
T
e
m
p
e
r
a
t
u
r
e
o
C
6 8 10 12 14 16 18 20
12
12.5
13
13.5
14
14.5
E
f
f
i
c
i
e
n
c
y
Ambient
Pv Temp
Efficienc
Y. I. A. Osman et al.
DOI: 10.4236/sgre.2018.97008 121 Smart Grid and Renewable Energy
Table 3. Statistical values of ambient temperature and PV surface temperature.
Ambient temperature PV temperature
Days
min max mean min max mean
โˆ’12.9 4.03 โˆ’1.93 โˆ’12.7 45.16 19.11 1th
โˆ’10.5 โˆ’1.36 โˆ’5.77 โˆ’10.4 31.80 0.99 2th
โˆ’13.2 โˆ’3.41 โˆ’6.22 โˆ’13.2 37.28 12.95 3th
โˆ’7.68 โˆ’0.13 โˆ’3.11 โˆ’7.68 27.38 2.57 4th
โˆ’10.7 โˆ’0.67 โˆ’4.21 โˆ’10.6 42.73 11.19 5th
โˆ’14.6 โˆ’2.18 โˆ’6.01 โˆ’14.4 38.13 14.62 6th
โˆ’9.02 5.93 1.31 โˆ’8.97 31.58 9.62 7th
Figure 4. The plots of the efficiency as a function of PV surface temperature of (9 Feb.
2015-15 Feb. 2015).
investigated and quantified. Based on the experimental results, the house-hold
PV panel performance is considerably varied. This deviation is ranged between
11.39% - 14.75%.
The house-hold PV panel performance is basically affected by the PV surface
temperature, therefore, multilevel of energy is detected. Approximately, 3% effi-
ciency variation is detected.
This investigation is exclusively considered solar radiation, wind speed, and
ambient temperature as an environmental factor, and future work should asso-
ciate other factors such as humidity, rainfall, seasonal variation.
Investigating and analyzing the influence of the environmental factors on the
-20 0 20 40 60
10
15
PV Temperature o
C 1th
day
Efficiency
(%)
-20 -10 0 10 20 30 40
12
14
16
PV Temperature o
C 2th
day
Efficiency
(%)
-20 -10 0 10 20 30 40
10
15
PV Temperature o
C 3th
day
Efficiency
(%)
-10 0 10 20 30
12
14
16
PV Temperature o
C 4th
day
Efficiency
(%)
-20 0 20 40 60
10
15
PV Temperature o
C 5th
day
Efficiency
(%)
-20 -10 0 10 20 30 40
10
15
PV Temperature o
C 6th
day
Efficiency
(%)
-10 0 10 20 30 40
12
14
16
PV Temperature o
C 7th
day
Efficiency
(%)
Y. I. A. Osman et al.
DOI: 10.4236/sgre.2018.97008 122 Smart Grid and Renewable Energy
Figure 5. The plots of the efficiency as a function of solar radiation of (9 Feb. 2015-15 Feb. 2015).
house-hold PV panel facilitate the process of assessment and prediction of per-
formance and the harvested power and thus accurately size the PV plants.
Conflicts of Interest
The authors declare no conflicts of interest regarding the publication of this pa-
per.
References
[1] Honrubia-Escribano, A., et al. (2018) Influence of Solar Technology in the Eco-
nomic Performance of PV Power Plants in Europe: A Comprehensive Analysis. Re-
newable and Sustainable Energy Reviews, 82, 488-501.
https://doi.org/10.1016/j.rser.2017.09.061
[2] Obeidat, F. (2018) A Comprehensive Review of Future Photovoltaic Systems. Solar
Energy, 163, 545-551. https://doi.org/10.1016/j.solener.2018.01.050
[3] Bai, A., et al. (2016) Technical and Economic Effects of Cooling of Monocrystalline
Photovoltaic Modules under Hungarian Conditions. Renewable and Sustainable
Energy Reviews, 60, 1086-1099. https://doi.org/10.1016/j.rser.2016.02.003
[4] Ndiaye, A., et al. (2014) Degradation Evaluation of Crystalline-Silicon Photovoltaic
Modules after a Few Operation Years in a Tropical Environment. Solar Energy, 103,
70-77. https://doi.org/10.1016/j.solener.2014.02.006
[5] Kahoul, N., Houabes, M. and Sadok, M. (2014) Assessing the Early Degradation of
Photovoltaic Modules Performance in the Saharan Region. Energy Conversion and
Management, 82, 320-326. https://doi.org/10.1016/j.enconman.2014.03.034
[6] Sen, R. and Bhattacharyya, S.C. (2014) Off-Grid Electricity Generation with Re-
-200 0 200 400 600 800 1000
10
12
14
16
Solar irradiance W/m2
1th
day
Efficiency
(%)
-200 0 200 400 600 800 1000
12
13
14
15
Solar irradiance W/m2
2th
day
Efficiency
(%)
-200 0 200 400 600 800 1000
10
12
14
16
Solar irradiance W/m2
3th
day
Efficiency
(%)
-200 0 200 400 600 800 1000
12
13
14
15
Solar irradiance W/m2
4th
day
Efficiency
(%)
-200 0 200 400 600 800 1000 1200
10
12
14
16
Solar irradiance W/m2
5th
day
Efficiency
(%)
-200 0 200 400 600 800 1000
10
12
14
16
Solar irradiance W/m2
6th
day
Efficiency
(%)
-200 0 200 400 600 800 1000
12
13
14
15
Solar irradiance W/m2
7th
day
Efficiency
(%)
Y. I. A. Osman et al.
DOI: 10.4236/sgre.2018.97008 123 Smart Grid and Renewable Energy
newable Energy Technologies in India: An Application of HOMER. Renewable
Energy, 62, 388-398. https://doi.org/10.1016/j.renene.2013.07.028
[7] Sieminski, A. (2014) International Energy Outlook. Energy Information Adminis-
tration (EIA), 18.
[8] Outlook, A.E. (2010) International Energy Outlook. 92010, Energy Information
Administration, Department of Energy, 1-15.
[9] Touati, F., et al. (2016) Investigation of Solar PV Performance under Doha Weather
Using a Customized Measurement and Monitoring System. Renewable Energy, 89,
564-577. https://doi.org/10.1016/j.renene.2015.12.046
[10] Bendib, B., Belmili, H. and Krim, F. (2015) A Survey of the Most Used MPPT Me-
thods: Conventional and Advanced Algorithms Applied for Photovoltaic Systems.
Renewable and Sustainable Energy Reviews, 45, 637-648.
https://doi.org/10.1016/j.rser.2015.02.009
[11] Skoplaki, E. and Palyvos, J. (2009) Operating Temperature of Photovoltaic Modules:
A Survey of Pertinent Correlations. Renewable Energy, 34, 23-29.
https://doi.org/10.1016/j.renene.2008.04.009
[12] Alami, A.H. (2014) Effects of Evaporative Cooling on Efficiency of Photovoltaic
Modules. Energy Conversion and Management, 77, 668-679.
https://doi.org/10.1016/j.enconman.2013.10.019
[13] Niลพetiฤ‡, S., et al. (2016) Water Spray Cooling Technique Applied on a Photovoltaic
Panel: The Performance Response. Energy Conversion and Management, 108,
287-296. https://doi.org/10.1016/j.enconman.2015.10.079
[14] Polo, J., Fernandez-Neira, W. and Alonso-Garcรญa, M. (2017) On the Use of Refer-
ence Modules as Irradiance Sensor for Monitoring and Modelling Rooftop PV Sys-
tems. Renewable Energy, 106, 186-191. https://doi.org/10.1016/j.renene.2017.01.026
[15] Yang, D. (2017) On Adding and Removing Sensors in a Solar Irradiance Monitor-
ing Network for Areal Forecasting and PV System Performance Evaluation. Solar
Energy, 155, 1417-1430. https://doi.org/10.1016/j.solener.2017.07.061
[16] Abdolzadeh, M. and Ameri, M. (2009) Improving the Effectiveness of a Photovol-
taic Water Pumping System by Spraying Water over the Front of Photovoltaic Cells.
Renewable Energy, 34, 91-96. https://doi.org/10.1016/j.renene.2008.03.024
[17] Habiballahi, M., Ameri, M. and Mansouri, S. (2015) Efficiency Improvement of
Photovoltaic Water Pumping Systems by Means of Water Flow Beneath Photovol-
taic Cells Surface. Journal of Solar Energy Engineering, 137, Article ID: 044501.
https://doi.org/10.1115/1.4029932
[18] Aelenei, L., et al. (2014) Thermal Performance of a Hybrid BIPV-PCM: Modeling,
Design and Experimental Investigation. Energy Procedia, 48, 474-483.
https://doi.org/10.1016/j.egypro.2014.02.056
[19] Ibrahim, H. and Anani, N. (2017) Variations of PV Module Parameters with Irra-
diance and Temperature. Energy Procedia, 134, 276-285.
https://doi.org/10.1016/j.egypro.2017.09.617
[20] Elbreki, A., et al. (2017) Towards Adopting Passive Heat Dissipation Approaches
for Temperature Regulation of PV Module as a Sustainable Solution. Renewable
and Sustainable Energy Reviews, 69, 961-1017.
https://doi.org/10.1016/j.rser.2016.09.054
[21] Bouraiou, A., et al. (2018) Experimental Investigation of Observed Defects in Crys-
talline Silicon PV Modules under Outdoor Hot Dry Climatic Conditions in Algeria.
Solar Energy, 159, 475-487. https://doi.org/10.1016/j.solener.2017.11.018
Y. I. A. Osman et al.
DOI: 10.4236/sgre.2018.97008 124 Smart Grid and Renewable Energy
[22] Masuko, K., et al. (2014) Achievement of More Than 25% Conversion Efficiency
with Crystalline Silicon Heterojunction Solar Cell. IEEE Journal of Photovoltaics, 4,
1433-1435. https://doi.org/10.1109/JPHOTOV.2014.2352151
[23] Kazem, H.A. and Chaichan, M.T. (2016) Experimental Analysis of the Effect of
Dustโ€™s Physical Properties on Photovoltaic Modules in Northern Oman. Solar
Energy, 139, 68-80. https://doi.org/10.1016/j.solener.2016.09.019
[24] Kankiewicz, A., Sengupta, M. and Moon, D. (2010) Observed Impacts of Transient
Clouds on Utility-Scale PV Fields. Proceedings of ASES National Solar Conference,
Phoenix, Arizona, USA, 17-22 May 2010.
[25] Curtright, A.E. and Apt, J. (2008) The Character of Power Output from Utility-Scale
Photovoltaic Systems. Progress in Photovoltaics: Research and Applications, 16,
241-247. https://doi.org/10.1002/pip.786
[26] Li, N., Liu, C. and Zha, D. (2016) Performance Evaluation of Chinese Photovoltaic
Companies with the Input-Oriented Dynamic SBM Model. Renewable Energy, 89,
489-497. https://doi.org/10.1016/j.renene.2015.12.028
[27] Azadeh, A., Ghaderi, S. and Maghsoudi, A. (2008) Location Optimization of Solar
Plants by an Integrated Hierarchical DEA PCA Approach. Energy Policy, 36,
3993-4004. https://doi.org/10.1016/j.enpol.2008.05.034
[28] Sueyoshi, T. and Goto, M. (2014) Photovoltaic Power Stations in Germany and the
United States: A Comparative Study by Data Envelopment Analysis. Energy Eco-
nomics, 42, 271-288. https://doi.org/10.1016/j.eneco.2014.01.004
[29] Garcรญa-Domingo, B., et al. (2014) Modelling the Influence of Atmospheric Condi-
tions on the Outdoor Real Performance of a CPV (Concentrated Photovoltaic)
Module. Energy, 70, 239-250. https://doi.org/10.1016/j.energy.2014.03.119
[30] Nishioka, K., et al. (2003) Field-Test Analysis of PV System Output Characteristics
Focusing on Module Temperature. Solar Energy Materials and Solar Cells, 75,
665-671. https://doi.org/10.1016/S0927-0248(02)00148-4
[31] Al-Shamani, A.N., et al. (2014) Nanofluids for Improved Efficiency in Cooling Solar
Collectorsโ€”A Review. Renewable and Sustainable Energy Reviews, 38, 348-367.
https://doi.org/10.1016/j.rser.2014.05.041
[32] McColl, S.J., Rodgers, P. and Eveloy, V. (2015) Thermal Management of Solar Pho-
tovoltaics Modules for Enhanced Power Generation. Renewable Energy, 82, 14-20.
https://doi.org/10.1016/j.renene.2014.09.015
[33] Gรถkmen, N., et al. (2016) Investigation of Wind Speed Cooling Effect on PV Panels
in Windy Locations. Renewable Energy, 90, 283-290.
https://doi.org/10.1016/j.renene.2016.01.017
[34] Obara, S.Y., et al. (2014) Output Prediction of Large-Scale Photovoltaics by
Wind-Condition Analysis Using 3D Topographic Maps. Solar Energy, 105,
157-169. https://doi.org/10.1016/j.solener.2014.03.007
[35] Schwingshackl, C., et al. (2013) Wind Effect on PV Module Temperature: Analysis
of Different Techniques for an Accurate Estimation. Energy Procedia, 40, 77-86.
https://doi.org/10.1016/j.egypro.2013.08.010
[36] Koehl, M., et al. (2011) Modeling of the Nominal Operating Cell Temperature
Based on Outdoor Weathering. Solar Energy Materials and Solar Cells, 95,
1638-1646. https://doi.org/10.1016/j.solmat.2011.01.020
[37] Gaglia, A.G., et al. (2017) Energy Efficiency of PV Panels under Real Outdoor Con-
ditionsโ€“An Experimental Assessment in Athens, Greece. Renewable Energy, 101,
236-243. https://doi.org/10.1016/j.renene.2016.08.051
Y. I. A. Osman et al.
DOI: 10.4236/sgre.2018.97008 125 Smart Grid and Renewable Energy
[38] Migan, G.-A. (2013) Study the Operating Temperature of a PV Module. Project
Report.
[39] Commission, I.E. (2005) Crystalline Silicon Terrestrial Photovoltaic (PV) Mod-
ulesโ€”Design Qualification and Type Approval. International Standard IEC,
61215-04.

More Related Content

Similar to SGRE_2018072714405435.pdf

comparative analysis of solar photovoltaic thermal (pvt) water and solar
comparative analysis of solar photovoltaic thermal (pvt) water and solarcomparative analysis of solar photovoltaic thermal (pvt) water and solar
comparative analysis of solar photovoltaic thermal (pvt) water and solarIJCMESJOURNAL
ย 
Passive Cooling on the Performance of Photovoltaic Solar Panels Operating in ...
Passive Cooling on the Performance of Photovoltaic Solar Panels Operating in ...Passive Cooling on the Performance of Photovoltaic Solar Panels Operating in ...
Passive Cooling on the Performance of Photovoltaic Solar Panels Operating in ...ijmech
ย 
Using Design of Experiments Approach to analysis Factors Effecting on the PV ...
Using Design of Experiments Approach to analysis Factors Effecting on the PV ...Using Design of Experiments Approach to analysis Factors Effecting on the PV ...
Using Design of Experiments Approach to analysis Factors Effecting on the PV ...ijtsrd
ย 
Design and Experimental Analysis of Solar air Conditioner
Design and Experimental Analysis of Solar air ConditionerDesign and Experimental Analysis of Solar air Conditioner
Design and Experimental Analysis of Solar air ConditionerIRJET Journal
ย 
Indoor and outdoor investigation comparison of photovoltaic thermal air colle...
Indoor and outdoor investigation comparison of photovoltaic thermal air colle...Indoor and outdoor investigation comparison of photovoltaic thermal air colle...
Indoor and outdoor investigation comparison of photovoltaic thermal air colle...journalBEEI
ย 
Experimental and Modeling Dynamic Study of the Indirect Solar Water Heater: A...
Experimental and Modeling Dynamic Study of the Indirect Solar Water Heater: A...Experimental and Modeling Dynamic Study of the Indirect Solar Water Heater: A...
Experimental and Modeling Dynamic Study of the Indirect Solar Water Heater: A...IJAAS Team
ย 
The Performance of a Cylindrical Microstrip Printed Antenna for TM10 Mode as...
The Performance of a Cylindrical Microstrip Printed Antenna for TM10  Mode as...The Performance of a Cylindrical Microstrip Printed Antenna for TM10  Mode as...
The Performance of a Cylindrical Microstrip Printed Antenna for TM10 Mode as...ijngnjournal
ย 
Temperature and Azimuth angle variation effect on the Building Integrated Pho...
Temperature and Azimuth angle variation effect on the Building Integrated Pho...Temperature and Azimuth angle variation effect on the Building Integrated Pho...
Temperature and Azimuth angle variation effect on the Building Integrated Pho...IOSR Journals
ย 
sustainability-12-00608-v2 (1).pdf
sustainability-12-00608-v2 (1).pdfsustainability-12-00608-v2 (1).pdf
sustainability-12-00608-v2 (1).pdfHaiderAddewany1
ย 
sustainability-12-00608-v2.pdf
sustainability-12-00608-v2.pdfsustainability-12-00608-v2.pdf
sustainability-12-00608-v2.pdfHaiderAddewany1
ย 
RENEWABLE ENERGY ALTERNATIVE FOR WASTEWATER TREATMENT PLANTS IN TRINIDAD - A ...
RENEWABLE ENERGY ALTERNATIVE FOR WASTEWATER TREATMENT PLANTS IN TRINIDAD - A ...RENEWABLE ENERGY ALTERNATIVE FOR WASTEWATER TREATMENT PLANTS IN TRINIDAD - A ...
RENEWABLE ENERGY ALTERNATIVE FOR WASTEWATER TREATMENT PLANTS IN TRINIDAD - A ...ijmech
ย 
IRJET - Effects of Temperature and Dust on the Behavior of Photovoltaic Systems
IRJET - Effects of Temperature and Dust on the Behavior of Photovoltaic SystemsIRJET - Effects of Temperature and Dust on the Behavior of Photovoltaic Systems
IRJET - Effects of Temperature and Dust on the Behavior of Photovoltaic SystemsIRJET Journal
ย 
Performance evaluation of solar-PV integrated green roof in Singapore
Performance evaluation of solar-PV integrated green roof in SingaporePerformance evaluation of solar-PV integrated green roof in Singapore
Performance evaluation of solar-PV integrated green roof in SingaporeAakanksha Dubey
ย 
factor affecting on PV performance
factor affecting on PV performancefactor affecting on PV performance
factor affecting on PV performanceakshay harad
ย 
Effect analysis of the different channel length and depth of photovoltaic the...
Effect analysis of the different channel length and depth of photovoltaic the...Effect analysis of the different channel length and depth of photovoltaic the...
Effect analysis of the different channel length and depth of photovoltaic the...IJECEIAES
ย 
Optimal thermo hydraulic performance of three sides artificially roughened so...
Optimal thermo hydraulic performance of three sides artificially roughened so...Optimal thermo hydraulic performance of three sides artificially roughened so...
Optimal thermo hydraulic performance of three sides artificially roughened so...Dr. Ashwini kumar
ย 
A literature review on industrially accepted MPPT techniques for solar PV system
A literature review on industrially accepted MPPT techniques for solar PV systemA literature review on industrially accepted MPPT techniques for solar PV system
A literature review on industrially accepted MPPT techniques for solar PV systemIJECEIAES
ย 
Impact of solar radiation and temperature levels on the variation of the seri...
Impact of solar radiation and temperature levels on the variation of the seri...Impact of solar radiation and temperature levels on the variation of the seri...
Impact of solar radiation and temperature levels on the variation of the seri...eSAT Journals
ย 

Similar to SGRE_2018072714405435.pdf (20)

comparative analysis of solar photovoltaic thermal (pvt) water and solar
comparative analysis of solar photovoltaic thermal (pvt) water and solarcomparative analysis of solar photovoltaic thermal (pvt) water and solar
comparative analysis of solar photovoltaic thermal (pvt) water and solar
ย 
Passive Cooling on the Performance of Photovoltaic Solar Panels Operating in ...
Passive Cooling on the Performance of Photovoltaic Solar Panels Operating in ...Passive Cooling on the Performance of Photovoltaic Solar Panels Operating in ...
Passive Cooling on the Performance of Photovoltaic Solar Panels Operating in ...
ย 
Using Design of Experiments Approach to analysis Factors Effecting on the PV ...
Using Design of Experiments Approach to analysis Factors Effecting on the PV ...Using Design of Experiments Approach to analysis Factors Effecting on the PV ...
Using Design of Experiments Approach to analysis Factors Effecting on the PV ...
ย 
Design and Experimental Analysis of Solar air Conditioner
Design and Experimental Analysis of Solar air ConditionerDesign and Experimental Analysis of Solar air Conditioner
Design and Experimental Analysis of Solar air Conditioner
ย 
Indoor and outdoor investigation comparison of photovoltaic thermal air colle...
Indoor and outdoor investigation comparison of photovoltaic thermal air colle...Indoor and outdoor investigation comparison of photovoltaic thermal air colle...
Indoor and outdoor investigation comparison of photovoltaic thermal air colle...
ย 
Experimental and Modeling Dynamic Study of the Indirect Solar Water Heater: A...
Experimental and Modeling Dynamic Study of the Indirect Solar Water Heater: A...Experimental and Modeling Dynamic Study of the Indirect Solar Water Heater: A...
Experimental and Modeling Dynamic Study of the Indirect Solar Water Heater: A...
ย 
The Performance of a Cylindrical Microstrip Printed Antenna for TM10 Mode as...
The Performance of a Cylindrical Microstrip Printed Antenna for TM10  Mode as...The Performance of a Cylindrical Microstrip Printed Antenna for TM10  Mode as...
The Performance of a Cylindrical Microstrip Printed Antenna for TM10 Mode as...
ย 
Temperature and Azimuth angle variation effect on the Building Integrated Pho...
Temperature and Azimuth angle variation effect on the Building Integrated Pho...Temperature and Azimuth angle variation effect on the Building Integrated Pho...
Temperature and Azimuth angle variation effect on the Building Integrated Pho...
ย 
sustainability-12-00608-v2 (1).pdf
sustainability-12-00608-v2 (1).pdfsustainability-12-00608-v2 (1).pdf
sustainability-12-00608-v2 (1).pdf
ย 
sustainability-12-00608-v2.pdf
sustainability-12-00608-v2.pdfsustainability-12-00608-v2.pdf
sustainability-12-00608-v2.pdf
ย 
RENEWABLE ENERGY ALTERNATIVE FOR WASTEWATER TREATMENT PLANTS IN TRINIDAD - A ...
RENEWABLE ENERGY ALTERNATIVE FOR WASTEWATER TREATMENT PLANTS IN TRINIDAD - A ...RENEWABLE ENERGY ALTERNATIVE FOR WASTEWATER TREATMENT PLANTS IN TRINIDAD - A ...
RENEWABLE ENERGY ALTERNATIVE FOR WASTEWATER TREATMENT PLANTS IN TRINIDAD - A ...
ย 
IRJET - Effects of Temperature and Dust on the Behavior of Photovoltaic Systems
IRJET - Effects of Temperature and Dust on the Behavior of Photovoltaic SystemsIRJET - Effects of Temperature and Dust on the Behavior of Photovoltaic Systems
IRJET - Effects of Temperature and Dust on the Behavior of Photovoltaic Systems
ย 
Performance evaluation of solar-PV integrated green roof in Singapore
Performance evaluation of solar-PV integrated green roof in SingaporePerformance evaluation of solar-PV integrated green roof in Singapore
Performance evaluation of solar-PV integrated green roof in Singapore
ย 
factor affecting on PV performance
factor affecting on PV performancefactor affecting on PV performance
factor affecting on PV performance
ย 
Effect analysis of the different channel length and depth of photovoltaic the...
Effect analysis of the different channel length and depth of photovoltaic the...Effect analysis of the different channel length and depth of photovoltaic the...
Effect analysis of the different channel length and depth of photovoltaic the...
ย 
Half Cycle Discrete Transformation for Voltage Sag Improvement in an Islanded...
Half Cycle Discrete Transformation for Voltage Sag Improvement in an Islanded...Half Cycle Discrete Transformation for Voltage Sag Improvement in an Islanded...
Half Cycle Discrete Transformation for Voltage Sag Improvement in an Islanded...
ย 
Optimal thermo hydraulic performance of three sides artificially roughened so...
Optimal thermo hydraulic performance of three sides artificially roughened so...Optimal thermo hydraulic performance of three sides artificially roughened so...
Optimal thermo hydraulic performance of three sides artificially roughened so...
ย 
45 design
45 design45 design
45 design
ย 
A literature review on industrially accepted MPPT techniques for solar PV system
A literature review on industrially accepted MPPT techniques for solar PV systemA literature review on industrially accepted MPPT techniques for solar PV system
A literature review on industrially accepted MPPT techniques for solar PV system
ย 
Impact of solar radiation and temperature levels on the variation of the seri...
Impact of solar radiation and temperature levels on the variation of the seri...Impact of solar radiation and temperature levels on the variation of the seri...
Impact of solar radiation and temperature levels on the variation of the seri...
ย 

More from HaiderAddewany1

More from HaiderAddewany1 (8)

FULLTEXT01.pdf
FULLTEXT01.pdfFULLTEXT01.pdf
FULLTEXT01.pdf
ย 
thotakura2020.pdf
thotakura2020.pdfthotakura2020.pdf
thotakura2020.pdf
ย 
COMPLETEREPORT.pdf
COMPLETEREPORT.pdfCOMPLETEREPORT.pdf
COMPLETEREPORT.pdf
ย 
said2018.pdf
said2018.pdfsaid2018.pdf
said2018.pdf
ย 
energies-14-05272-v2.pdf
energies-14-05272-v2.pdfenergies-14-05272-v2.pdf
energies-14-05272-v2.pdf
ย 
fouad2017.pdf
fouad2017.pdffouad2017.pdf
fouad2017.pdf
ย 
1.pdf
1.pdf1.pdf
1.pdf
ย 
1.docx
1.docx1.docx
1.docx
ย 

Recently uploaded

Call Girls Chakan ( 8250092165 ) Cheap rates call girls | Get low budget
Call Girls Chakan ( 8250092165 ) Cheap rates call girls | Get low budgetCall Girls Chakan ( 8250092165 ) Cheap rates call girls | Get low budget
Call Girls Chakan ( 8250092165 ) Cheap rates call girls | Get low budgetSareena Khatun
ย 
Charbagh \ Book Call Girls in Lucknow Finest Escorts Service 9548273370 Avail...
Charbagh \ Book Call Girls in Lucknow Finest Escorts Service 9548273370 Avail...Charbagh \ Book Call Girls in Lucknow Finest Escorts Service 9548273370 Avail...
Charbagh \ Book Call Girls in Lucknow Finest Escorts Service 9548273370 Avail...HyderabadDolls
ย 
Call Girls in Rajkot / 8250092165 Genuine Call girls with real Photos and Number
Call Girls in Rajkot / 8250092165 Genuine Call girls with real Photos and NumberCall Girls in Rajkot / 8250092165 Genuine Call girls with real Photos and Number
Call Girls in Rajkot / 8250092165 Genuine Call girls with real Photos and NumberSareena Khatun
ย 
๐Ÿ’š Call Girls Chamarajanagar 9332606886 HOT & SEXY Models beautiful and charm...
๐Ÿ’š Call Girls Chamarajanagar  9332606886 HOT & SEXY Models beautiful and charm...๐Ÿ’š Call Girls Chamarajanagar  9332606886 HOT & SEXY Models beautiful and charm...
๐Ÿ’š Call Girls Chamarajanagar 9332606886 HOT & SEXY Models beautiful and charm...kumargunjan9515
ย 
Call Girls Kothrud / 8250092165 Genuine Call girls with real Photos and Number
Call Girls Kothrud / 8250092165 Genuine Call girls with real Photos and NumberCall Girls Kothrud / 8250092165 Genuine Call girls with real Photos and Number
Call Girls Kothrud / 8250092165 Genuine Call girls with real Photos and NumberSareena Khatun
ย 
Call Girls Surat ( 8250092165 ) Cheap rates call girls | Get low budget
Call Girls Surat ( 8250092165 ) Cheap rates call girls | Get low budgetCall Girls Surat ( 8250092165 ) Cheap rates call girls | Get low budget
Call Girls Surat ( 8250092165 ) Cheap rates call girls | Get low budgetSareena Khatun
ย 
Call Girl Service in manesar 9332606886Call Girls Advance Cash On Delivery S...
Call Girl Service in manesar  9332606886Call Girls Advance Cash On Delivery S...Call Girl Service in manesar  9332606886Call Girls Advance Cash On Delivery S...
Call Girl Service in manesar 9332606886Call Girls Advance Cash On Delivery S...kumargunjan9515
ย 
Top profile Call Girls In Chhapra [ 7014168258 ] Call Me For Genuine Models W...
Top profile Call Girls In Chhapra [ 7014168258 ] Call Me For Genuine Models W...Top profile Call Girls In Chhapra [ 7014168258 ] Call Me For Genuine Models W...
Top profile Call Girls In Chhapra [ 7014168258 ] Call Me For Genuine Models W...gajnagarg
ย 
๐Ÿ’ž Safe And Secure Call Girls Agra ๐Ÿ’ฏNiamh ๐Ÿ“ฒ๐Ÿ”6378878445๐Ÿ”Call Girl No๐Ÿ’ฐAdvance C...
๐Ÿ’ž Safe And Secure Call Girls Agra  ๐Ÿ’ฏNiamh ๐Ÿ“ฒ๐Ÿ”6378878445๐Ÿ”Call Girl No๐Ÿ’ฐAdvance C...๐Ÿ’ž Safe And Secure Call Girls Agra  ๐Ÿ’ฏNiamh ๐Ÿ“ฒ๐Ÿ”6378878445๐Ÿ”Call Girl No๐Ÿ’ฐAdvance C...
๐Ÿ’ž Safe And Secure Call Girls Agra ๐Ÿ’ฏNiamh ๐Ÿ“ฒ๐Ÿ”6378878445๐Ÿ”Call Girl No๐Ÿ’ฐAdvance C...vershagrag
ย 
romantic date with Call Girls in Charkhi Dadri 9332606886Call Girls Advance ...
romantic date with Call Girls in Charkhi Dadri  9332606886Call Girls Advance ...romantic date with Call Girls in Charkhi Dadri  9332606886Call Girls Advance ...
romantic date with Call Girls in Charkhi Dadri 9332606886Call Girls Advance ...kumargunjan9515
ย 
Call Girls in Rajpur Sonarpur / 8250092165 Genuine Call girls with real Photo...
Call Girls in Rajpur Sonarpur / 8250092165 Genuine Call girls with real Photo...Call Girls in Rajpur Sonarpur / 8250092165 Genuine Call girls with real Photo...
Call Girls in Rajpur Sonarpur / 8250092165 Genuine Call girls with real Photo...Sareena Khatun
ย 
Call Girls Vanasthalipuram - 8250092165 Our call girls are sure to provide yo...
Call Girls Vanasthalipuram - 8250092165 Our call girls are sure to provide yo...Call Girls Vanasthalipuram - 8250092165 Our call girls are sure to provide yo...
Call Girls Vanasthalipuram - 8250092165 Our call girls are sure to provide yo...kumargunjan9515
ย 
Call girls Service Songadh / 8250092165 Genuine Call girls with real Photos a...
Call girls Service Songadh / 8250092165 Genuine Call girls with real Photos a...Call girls Service Songadh / 8250092165 Genuine Call girls with real Photos a...
Call girls Service Songadh / 8250092165 Genuine Call girls with real Photos a...Sareena Khatun
ย 
Call Girls Nagpur / 8250092165 Genuine Call girls with real Photos and Number
Call Girls Nagpur / 8250092165 Genuine Call girls with real Photos and NumberCall Girls Nagpur / 8250092165 Genuine Call girls with real Photos and Number
Call Girls Nagpur / 8250092165 Genuine Call girls with real Photos and NumberSareena Khatun
ย 
Call Girl In Srinagar Call Girls (Adult Only) ๐Ÿ’ฏCall Us ๐Ÿ” 6378878445 ๐Ÿ” ๐Ÿ’ƒ Escor...
Call Girl In Srinagar Call Girls (Adult Only) ๐Ÿ’ฏCall Us ๐Ÿ” 6378878445 ๐Ÿ” ๐Ÿ’ƒ Escor...Call Girl In Srinagar Call Girls (Adult Only) ๐Ÿ’ฏCall Us ๐Ÿ” 6378878445 ๐Ÿ” ๐Ÿ’ƒ Escor...
Call Girl In Srinagar Call Girls (Adult Only) ๐Ÿ’ฏCall Us ๐Ÿ” 6378878445 ๐Ÿ” ๐Ÿ’ƒ Escor...vershagrag
ย 
Call Girls in Anand - 8250092165 Our call girls are sure to provide you with ...
Call Girls in Anand - 8250092165 Our call girls are sure to provide you with ...Call Girls in Anand - 8250092165 Our call girls are sure to provide you with ...
Call Girls in Anand - 8250092165 Our call girls are sure to provide you with ...Sareena Khatun
ย 
Call Girls in Morbi - 8250092165 Our call girls are sure to provide you with ...
Call Girls in Morbi - 8250092165 Our call girls are sure to provide you with ...Call Girls in Morbi - 8250092165 Our call girls are sure to provide you with ...
Call Girls in Morbi - 8250092165 Our call girls are sure to provide you with ...Sareena Khatun
ย 
High Profile Call Girls Service in Sangli 9332606886 HOT & SEXY Models beaut...
High Profile Call Girls Service in Sangli  9332606886 HOT & SEXY Models beaut...High Profile Call Girls Service in Sangli  9332606886 HOT & SEXY Models beaut...
High Profile Call Girls Service in Sangli 9332606886 HOT & SEXY Models beaut...Sareena Khatun
ย 
Foreigner Call Girls in junagadh 8250092165 Call Girls Advance Cash On Deliv...
Foreigner Call Girls in junagadh  8250092165 Call Girls Advance Cash On Deliv...Foreigner Call Girls in junagadh  8250092165 Call Girls Advance Cash On Deliv...
Foreigner Call Girls in junagadh 8250092165 Call Girls Advance Cash On Deliv...Sareena Khatun
ย 

Recently uploaded (20)

Call Girls Chakan ( 8250092165 ) Cheap rates call girls | Get low budget
Call Girls Chakan ( 8250092165 ) Cheap rates call girls | Get low budgetCall Girls Chakan ( 8250092165 ) Cheap rates call girls | Get low budget
Call Girls Chakan ( 8250092165 ) Cheap rates call girls | Get low budget
ย 
Charbagh \ Book Call Girls in Lucknow Finest Escorts Service 9548273370 Avail...
Charbagh \ Book Call Girls in Lucknow Finest Escorts Service 9548273370 Avail...Charbagh \ Book Call Girls in Lucknow Finest Escorts Service 9548273370 Avail...
Charbagh \ Book Call Girls in Lucknow Finest Escorts Service 9548273370 Avail...
ย 
Call Girls in Rajkot / 8250092165 Genuine Call girls with real Photos and Number
Call Girls in Rajkot / 8250092165 Genuine Call girls with real Photos and NumberCall Girls in Rajkot / 8250092165 Genuine Call girls with real Photos and Number
Call Girls in Rajkot / 8250092165 Genuine Call girls with real Photos and Number
ย 
๐Ÿ’š Call Girls Chamarajanagar 9332606886 HOT & SEXY Models beautiful and charm...
๐Ÿ’š Call Girls Chamarajanagar  9332606886 HOT & SEXY Models beautiful and charm...๐Ÿ’š Call Girls Chamarajanagar  9332606886 HOT & SEXY Models beautiful and charm...
๐Ÿ’š Call Girls Chamarajanagar 9332606886 HOT & SEXY Models beautiful and charm...
ย 
Call Girls Kothrud / 8250092165 Genuine Call girls with real Photos and Number
Call Girls Kothrud / 8250092165 Genuine Call girls with real Photos and NumberCall Girls Kothrud / 8250092165 Genuine Call girls with real Photos and Number
Call Girls Kothrud / 8250092165 Genuine Call girls with real Photos and Number
ย 
Call Girls Surat ( 8250092165 ) Cheap rates call girls | Get low budget
Call Girls Surat ( 8250092165 ) Cheap rates call girls | Get low budgetCall Girls Surat ( 8250092165 ) Cheap rates call girls | Get low budget
Call Girls Surat ( 8250092165 ) Cheap rates call girls | Get low budget
ย 
Call Girl Service in manesar 9332606886Call Girls Advance Cash On Delivery S...
Call Girl Service in manesar  9332606886Call Girls Advance Cash On Delivery S...Call Girl Service in manesar  9332606886Call Girls Advance Cash On Delivery S...
Call Girl Service in manesar 9332606886Call Girls Advance Cash On Delivery S...
ย 
Top profile Call Girls In Chhapra [ 7014168258 ] Call Me For Genuine Models W...
Top profile Call Girls In Chhapra [ 7014168258 ] Call Me For Genuine Models W...Top profile Call Girls In Chhapra [ 7014168258 ] Call Me For Genuine Models W...
Top profile Call Girls In Chhapra [ 7014168258 ] Call Me For Genuine Models W...
ย 
๐Ÿ’ž Safe And Secure Call Girls Agra ๐Ÿ’ฏNiamh ๐Ÿ“ฒ๐Ÿ”6378878445๐Ÿ”Call Girl No๐Ÿ’ฐAdvance C...
๐Ÿ’ž Safe And Secure Call Girls Agra  ๐Ÿ’ฏNiamh ๐Ÿ“ฒ๐Ÿ”6378878445๐Ÿ”Call Girl No๐Ÿ’ฐAdvance C...๐Ÿ’ž Safe And Secure Call Girls Agra  ๐Ÿ’ฏNiamh ๐Ÿ“ฒ๐Ÿ”6378878445๐Ÿ”Call Girl No๐Ÿ’ฐAdvance C...
๐Ÿ’ž Safe And Secure Call Girls Agra ๐Ÿ’ฏNiamh ๐Ÿ“ฒ๐Ÿ”6378878445๐Ÿ”Call Girl No๐Ÿ’ฐAdvance C...
ย 
romantic date with Call Girls in Charkhi Dadri 9332606886Call Girls Advance ...
romantic date with Call Girls in Charkhi Dadri  9332606886Call Girls Advance ...romantic date with Call Girls in Charkhi Dadri  9332606886Call Girls Advance ...
romantic date with Call Girls in Charkhi Dadri 9332606886Call Girls Advance ...
ย 
Call Girls in Rajpur Sonarpur / 8250092165 Genuine Call girls with real Photo...
Call Girls in Rajpur Sonarpur / 8250092165 Genuine Call girls with real Photo...Call Girls in Rajpur Sonarpur / 8250092165 Genuine Call girls with real Photo...
Call Girls in Rajpur Sonarpur / 8250092165 Genuine Call girls with real Photo...
ย 
Call Girls Vanasthalipuram - 8250092165 Our call girls are sure to provide yo...
Call Girls Vanasthalipuram - 8250092165 Our call girls are sure to provide yo...Call Girls Vanasthalipuram - 8250092165 Our call girls are sure to provide yo...
Call Girls Vanasthalipuram - 8250092165 Our call girls are sure to provide yo...
ย 
Call girls Service Songadh / 8250092165 Genuine Call girls with real Photos a...
Call girls Service Songadh / 8250092165 Genuine Call girls with real Photos a...Call girls Service Songadh / 8250092165 Genuine Call girls with real Photos a...
Call girls Service Songadh / 8250092165 Genuine Call girls with real Photos a...
ย 
Call Girls Nagpur / 8250092165 Genuine Call girls with real Photos and Number
Call Girls Nagpur / 8250092165 Genuine Call girls with real Photos and NumberCall Girls Nagpur / 8250092165 Genuine Call girls with real Photos and Number
Call Girls Nagpur / 8250092165 Genuine Call girls with real Photos and Number
ย 
Call Girl In Srinagar Call Girls (Adult Only) ๐Ÿ’ฏCall Us ๐Ÿ” 6378878445 ๐Ÿ” ๐Ÿ’ƒ Escor...
Call Girl In Srinagar Call Girls (Adult Only) ๐Ÿ’ฏCall Us ๐Ÿ” 6378878445 ๐Ÿ” ๐Ÿ’ƒ Escor...Call Girl In Srinagar Call Girls (Adult Only) ๐Ÿ’ฏCall Us ๐Ÿ” 6378878445 ๐Ÿ” ๐Ÿ’ƒ Escor...
Call Girl In Srinagar Call Girls (Adult Only) ๐Ÿ’ฏCall Us ๐Ÿ” 6378878445 ๐Ÿ” ๐Ÿ’ƒ Escor...
ย 
Jual Obat Aborsi Sorong, Wa : 0822/2310/9953 Apotik Jual Obat Cytotec Di Sorong
Jual Obat Aborsi Sorong, Wa : 0822/2310/9953 Apotik Jual Obat Cytotec Di SorongJual Obat Aborsi Sorong, Wa : 0822/2310/9953 Apotik Jual Obat Cytotec Di Sorong
Jual Obat Aborsi Sorong, Wa : 0822/2310/9953 Apotik Jual Obat Cytotec Di Sorong
ย 
Call Girls in Anand - 8250092165 Our call girls are sure to provide you with ...
Call Girls in Anand - 8250092165 Our call girls are sure to provide you with ...Call Girls in Anand - 8250092165 Our call girls are sure to provide you with ...
Call Girls in Anand - 8250092165 Our call girls are sure to provide you with ...
ย 
Call Girls in Morbi - 8250092165 Our call girls are sure to provide you with ...
Call Girls in Morbi - 8250092165 Our call girls are sure to provide you with ...Call Girls in Morbi - 8250092165 Our call girls are sure to provide you with ...
Call Girls in Morbi - 8250092165 Our call girls are sure to provide you with ...
ย 
High Profile Call Girls Service in Sangli 9332606886 HOT & SEXY Models beaut...
High Profile Call Girls Service in Sangli  9332606886 HOT & SEXY Models beaut...High Profile Call Girls Service in Sangli  9332606886 HOT & SEXY Models beaut...
High Profile Call Girls Service in Sangli 9332606886 HOT & SEXY Models beaut...
ย 
Foreigner Call Girls in junagadh 8250092165 Call Girls Advance Cash On Deliv...
Foreigner Call Girls in junagadh  8250092165 Call Girls Advance Cash On Deliv...Foreigner Call Girls in junagadh  8250092165 Call Girls Advance Cash On Deliv...
Foreigner Call Girls in junagadh 8250092165 Call Girls Advance Cash On Deliv...
ย 

SGRE_2018072714405435.pdf

  • 1. Smart Grid and Renewable Energy, 2018, 9, 113-125 http://www.scirp.org/journal/sgre ISSN Online: 2151-4844 ISSN Print: 2151-481X DOI: 10.4236/sgre.2018.97008 Jul. 30, 2018 113 Smart Grid and Renewable Energy Experimental Study of Environmental Impact on the Efficiency of a House-Hold PV Panel Yassir Idris Abdalla Osman1,2,3, Jinping Li1,2,3*, Xiaofei Zhen1,2,3 1 Western China Energy & Environment Research Center, Lanzhou University of Technology, Lanzhou, China 2 Gansu Key Laboratory of Complementary Energy System of Biomass and Solar Energy, Lanzhou, China 3 China Northwestern Collaborative Innovation Center of Key Technology for Northwest Low Carbon Urbanization, Lanzhou, China Abstract House-hold PV panels are widely used; however, their performance is signif- icantly degraded under real operating conditions. Environmental factors such as ambient temperature, wind speed, and solar irradiance has a major impact on the house-hold PV panel efficiency. In this paper an experimental study was conducted during the winter period in a single building in Minqin coun- ty, Gansu province, China. The experimental measurements were used to quantify the house-hold PV panel performance and operating characteristics. Based on the experimental results the house-hold PV panel performance is basically affected by the PV surface temperature, therefore, multilevel of energy is detected. Approximately 3% efficiency variation is detected due to the impact of the environmental factors. Keywords House-Hold PV Panel, Environmental Factors, Photovoltaic Efficiency 1. Introduction Among all the available electricity sources, solar photovoltaic (PV) is the most popular for installation [1]. PV technology witnessed a significant reduction in the cost and appreciable progress in increasing the efficiency [2] [3]. Generally, the standard test conditions are considered in most cases to address the PV per- formance specification, however, there is a considerable variation when the ac- tual conditions are adopted. A part of the irradiance received by the PV panel is transformed into electric- ity, and the other is transformed into heat losses which is responsible for reduc- How to cite this paper: Osman, Y.I.A., Li, J.P. and Zhen, X.F. (2018) Experimental Study of Environmental Impact on the Efficiency of a House-Hold PV Panel. Smart Grid and Renewable Energy, 9, 113-125. https://doi.org/10.4236/sgre.2018.97008 Received: July 7, 2018 Accepted: July 27, 2018 Published: July 30, 2018 Copyright ยฉ 2018 by authors and Scientific Research Publishing Inc. This work is licensed under the Creative Commons Attribution International License (CC BY 4.0). http://creativecommons.org/licenses/by/4.0/ Open Access
  • 2. Y. I. A. Osman et al. DOI: 10.4236/sgre.2018.97008 114 Smart Grid and Renewable Energy ing the PV panel efficiency [4] [5]. Altitude and azimuth play a crucial role in determination of sun position during the day [6]. It is evidence that the maxi- mum reception of solar radiation occurs when the PV panel is perpendicular to the sun radiation [7] [8]. Many publications accounting 0.08% of loss takes place when the location of the PV panel is diverged from the south particularly in azimuth angle [9]. Basically, the PV panel output power is directly proportion to the solar radiation [10]. Due to the approximate linearity the PV current is in- creased in accordance with the increment of the solar radiation [11] [12] [13]. Regarding this approximate linearity, the influence of the solar irradiance on the PV output current is hard to enumerate [14] [15]. In order to address the influence of ambient temperature on the PV panel functionality, two parameters exist short circuit current sc I and open circuit volts oc V . When the PV module temperature is increasing, the short circuit witnessed an insignificant increase (ranged between 0.04 and 0.09%/K), in con- trast to open circuit voltage, it suffers a considerable degradation (up to โˆ’0.45%/K for crystalline silicon) [16] [17]. The efficiency of the PV panel is va- ried according to the PV type under consideration. In the body of literature, it was reported that when the ambient temperature increased by 1หšC, the efficiency is reduced within the range of 0.35% - 0.8% [18] [19] [20] [21]. An experimental work concerns the effects of temperature coefficient on several silicon-based PV types, which reveals a loss of 3% - 5% occur as a result of 10หšC variation [22]. Some publications addressed the influence of ambient temperature on the PV panel performance considering geographical localization. Within the context, the Crystalline PV panel showed a reduction of 0.45% when the temperature rises 1หšC in [23] and 0.5 in [24]. For materials such as amorphous silicon, cad- mium Telluride and copper-indium-gallium-diselenide which are used in thin film PV panels, the performance degradation falls in the range of 0.21% - 0.36% [25] [26] [27] [28]. Generally, the increment in the ambient temperature is cor- related with performance degradation, and this fact is revealed in [29] [30]. By considering a water-based cooling technique, the PV surface temperature wit- ness a reduction ranged 5หšC to 23หšC which enhance the performance from 0 % to 22% [31]. Many researchers have proposed different approaches regarding the influence of wind on the PV module temperature. Wind has the ability of cooling the PV module within the range of 15หšC - 20หšC when the wind speed is 10 m/s under 1000 W/m2 of solar irradiance [32]. A considerable variation on the PV panel operation characteristic is detected due to the high dynamic nature of the Wind [29] [33]. In highly dynamic wind regions, the PV panel performance reaches up to 18%, according to the experimental results in [34]. However, the influence of the wind speed on the PV panel performance is quietly trivial in contrast to the ambient temperature and solar irradiance. A method known as in-situ is consi- dered in order to examine the experimental data and for validation purpose. One drawback associated with this method is that, the experimental data need to be
  • 3. Y. I. A. Osman et al. DOI: 10.4236/sgre.2018.97008 115 Smart Grid and Renewable Energy substituted by numerical weather prediction [35] [36]. Generally, the house-hold PV panel is affected by numerous environmental factors such as seasonal variation, humidity, rainfall, positioning, etc. However, the influences of these factors are not considered in this investigation. Regarding the unique weather conditions of Minqin County, the house-hold PV panel performance is expected to vary in many aspects. Accordingly, the main objective of this work is to quantify the performance of the house-hold PV panel and reveal the operating characteristics as well based on the experimental results. A house-hold PV panel system was built and tested as well. The environmen- tal factors are measured and recorded through the data acquisition equipment. The experimental results are extensively analyzed and discussed. 2. Photovoltaic Surface Temperature Theory The relationship regarding the ambient temperature (Ta) and the photovoltaic surface temperature (Tpv) is nearly linear. Basically, the variation of (Tpv) and (Ta) is a function of solar irradiance, and this result is associated with the effect of wind speed. The parameter (Tpv) is a function of (Ta) insignificantly influ- enced by solar irradiance (G) and wind speed (v). By taking into account the standard values for beta coefficients 0.74, 0.33, and โˆ’0.11 respectively, the cor- responding linear correlation is obtained [37]. ( ) ( ) ( ) ( ) ( ) 2 2.08 0.13 1.038 0.004 0.0182 0.0001 1.13 0.02 0.96 pv a T T G v R = ยฑ + ยฑ โ‹… + ยฑ โ‹… โˆ’ ยฑ โ‹… = (1) The most common expression addressed the PV module temperature is given in Equation (2) ( ) ( ) , 1 pv a NOCT a NOCT NOCT T T T T G = + โ‹… โˆ’ (2) where NOCT T is the temperature at nominal operating cell temperature ( ( ) NOCT G = 800 W/m2 , Ta = 20หšC, v = 1 m/s), NOCT T is varying according to the PV tech- nology a typical value for NOCT T is 45หšC. According to the literature, the typical PV operating temperature is at 45หšC, the best at 33หšC and the worst at 58หšC [38]. This expression does not consider the wind cooling influence. A compact PV temperature expression is given by: 0.035 pv a T T G =+ โ‹… (3) In order to consider wind speed factor, the following expression can be used: 0.032 8.91 2 pv a T T G v = + โ‹… + โ‹… (4) 3. PV Efficiency Theory The efficiency of the PV panel is positively influenced by wind speed. However, this influence is not vital. Within the body of literature, it is reported that, the
  • 4. Y. I. A. Osman et al. DOI: 10.4236/sgre.2018.97008 116 Smart Grid and Renewable Energy wind speed influence varies between 1.3 and 1.65 m/s [28] [29] [30] [31] [32]. However, regarding the high dynamic nature of wind factor, it is quite difficult to be quantified. The factor that has a vital influence on the PV efficiency is the pv T . By associating these values 0.85, โˆ’0.39, and 0.32 respectively, for standard beta coefficient, the following linear correlation is obtained to address the actual PV efficiency (ฮท%) ( ) ( ) ( ) ( ) ( )( ) 2 6.2 0.2 0.0312 0.0004 0.176 0.007 4.2 0.2 0.53 pv T AM R ฯ„ ฮท ฮฑ ฮธ ยฑ = โ‹… ยฑ โˆ’ โ‹… ยฑ โ‹… โˆ’ โ‹… + ยฑ โ‹… = (5) where ฮฑ and ฯ„ are absorptance and transmittance respectively. AM is the air mass (1.6) [39], and ฮธ is the solar zenith angle. Another expression that associates the actual operating condition and the standard test condition (STC) is given by: ( ) ( ) ( ) ( ) ( )( ) 2 1.7 0.2 0.631 0.008 0.176 0.007 4.2 0.2 0.53 k AM R ฮท ฮท ฯ„ฮฑ ฮธ = โˆ’ ยฑ + ยฑ โ‹… โˆ’ ยฑ โ‹… + ยฑ โ‹… = (6) where k ฮท is efficiency under specific STC conditions. Based on Equation (5) and Equation (6) the actual efficiency is addressed as: ( ) ( ) ( ) ( ) ( ) ( ) ( )( ) 2 4 2 , 2 7.8 0.2 3.74 0.07 10 10 0.8 0.3 10 0.197 3.2 0.008 2.6 0.2 0. 0.51 2 a x T G v AM R ฮท ฯ„ฮฑ ฮธ โˆ’ โˆ’ โˆ’ = ยฑ โˆ’ ยฑ โ‹… โ‹… โ‹… โ‹… + ยฑ โ‹… โ‹… โˆ’ ยฑ โ‹… โ‹… = โˆ’ ยฑ ยฑ + (7) The amount of average deviation when Equation (7) is considered to calculate the photovoltaic efficiency is about 2% of the actual measured efficiency. It is evidence that Equation (7) can be used to predict the photovoltaic efficiency re- gardless region variation, environmental factors and season variation [37]. 4. Experimental Setup This experiment is conducted in a single building in Minqin county. The lowest average solar radiation on the tilted surface of the local altitude is 13 MJ/m2 while the peak solar irradiance is 15 MJ/m2 . The PV panels are fabricated by Xinsheng PV Technology Co. Ltd. A total of 10 monocrystalline silicon PV is utilized. The PV specifications are listed in Ta- ble 1. The overall DC of the batteries group is 24 V, the inverter efficiency is 80%, and the battery depth is 60%. The list of the experimental instruments is presented in Table 2 followed by the schematic of the experiment setup Figure 1. 5. Experimental Analysis For this experiment the following factors are considered and quantified, the wind speed (v, m/s2 ), solar irradiance (G, W/m2 ), ambient temperature (Ta, หšC), photovoltaic surface temperature (Tpv, หšC). This experiment is conducted over one week started at 9 Feb. 2015 and ended on 15 Feb. 2015. The process of col- lecting data extended from 0800 oโ€™clock to 1900 oโ€™clock, each day 8286
  • 5. Y. I. A. Osman et al. DOI: 10.4236/sgre.2018.97008 117 Smart Grid and Renewable Energy Table 1. PV panel specification. Peak Power (Pmax) 100 w Voltage at Pmax 18 V Current at Pmax 5.55 A Current at Pmax 21.6 V Open circuit voltage 21.6 V Short circuit current 5.95 A Size 1200*540*30 mm Weight 9.0 KGS Table 2. The experimental instruments. Parameters Device model Specifications Manufacturer Wind speed YGC-FS Wind speed sensor Range: 0 - 45 m Accuracy: ยฑ(0.3 + 0.03 V) Resolving power: 0.1 m/s Wuhan Yi Valley Science and technology Company Limited Temperature PT 100 Temperature sensor Range: โˆ’50หšC - 100หšC Accuracy: ยฑ1หšC Beijing science and technology Saiyiling Limited company Photovoltaic array output voltage CJ-DA61-D DC voltmeter Range: 0 - 50 V Precision: 0.5 s Shanghai Chu Jing electric Limited company Photovoltaic array Output current CJ-DA61-D DC ammeter Range: 0 - 25 Ah Accuracy: 0.5 s Shanghai Chu Jing electric Limited company Data acquisition instrument 34972A Agilent Technology Limited company Solar irradiance CG-07 Solar Radiometer Sensitivity: 7 - 14 mv/kWโˆ™mโˆ’2 Range: 0.3 - 3.2 ฮผm Handan Development Zone Qing Yi Electronic Technology Co., Ltd. Figure 1. Schematic diagram of the experiment setup. measurements are recorded. Figure 2(a) presents the temperature for the entire week, and boxplot is adopted to present the measurements. Measurement ranged 1st to 3rd quartile is included within the box and the difference is known as the interquartile range (IQR). The minimum and the maximum are presented by whiskers below and above the rectangular respectively. Measurements that are three times or greater than the 3rd quartile or three times the inter quartile range or lower than the 1st quartile are designated outlier and plotted as red plus signs. PV Panel Inverter Data logger ~ = Ambient temperature (Ta, OC) Wind speed (v, m/s2) Solar radiation (G, W/m2) Control board
  • 6. Y. I. A. Osman et al. DOI: 10.4236/sgre.2018.97008 118 Smart Grid and Renewable Energy (a) (b) (c) Figure 2. Statistical plots of the experimental measurements of (9 Feb. 2015-15 Feb. 2015). (a) Ambient temperature; (b) Wind speed; (c) Solar irradiance. -14 -12 -10 -8 -6 -4 -2 0 2 4 6 1 2 3 4 5 6 7 D a y s A m b i e n t T e m p e r a t u r e 0 5 10 15 20 25 30 1 2 3 4 5 6 7 D a y s W i n d s p e e d 0 100 200 300 400 500 600 700 800 900 1000 1 2 3 4 5 6 7 D a y s S o l a r i r r a d i a n c e
  • 7. Y. I. A. Osman et al. DOI: 10.4236/sgre.2018.97008 119 Smart Grid and Renewable Energy Figure 2(a) reveals that the minimum ambient temperature is โˆ’14.6หšC detected on the 6th day, the maximum temperature is 5.9หšC detected in the 7th , while the maximum mean is 1.31หšC detected in the 7th . The outliers only detected in the 3th and 5th days where the temperature falls below โˆ’13.2หšC and โˆ’10.7หšC respective- ly. According to the measurements the temperature is less than 16หšC a day. Fig- ure 2(b) shows the record of the wind speed data per day for the same week. A significant variation is shown by the wind speed and described by several out- liers. The minimum wind speed is 0.18 m/s detected on the 3th day, the maxi- mum wind speed is 32.97 m/s is detected on the 7th day, and the maximum mean is 4.99 m/s detected on the 7th day. Generally, the wind variation is lower than 33 m/s. The solar irradiance measurements are shown in Figure 2(c) for the same period. The outliers are only detected on the 2nd day when the solar radiation is exceeding 800 W/m2 . The minimum solar irradiance is โˆ’3.8 W/m2 witnessed on the 1st day, the maximum solar irradiance is 1040 measured on the 5th day, and the maximum mean is 536.3 W/m2 recorded on the 1st day. The variation of solar irradiance during the experiment is more than 800 W/m2 per day. In Figure 3 the (Tpv) and (Ta) are depicted as a function of the day hours for all measurements of the week. These figures reveal the dependence of PV surface temperature on the solar irradiance. What is interesting about the data in Table 3 is that at 0800 and 1900 0โ€™clock in some days the (Tpv) measurements are lower than (Ta). This is mainly due to the influence of wind. Based on the experimental results, as shown in Figure 4 the minimum effi- ciency is 11.52% achieved during the 5th day where the wind speed is ranged be- tween 1.19 m/s and 5.97 m/s; the minimum and maximum ambient temperature is โˆ’10.7หšC and โˆ’0.67หšC respectively; the mean of ambient temperature is โˆ’4.2หšC; the solar irradiance is ranged (โˆ’2.80 - 408.4) W/m2 . The maximum efficiency being 14.75% is detected during the 1st day where the wind speed is ranged between (0.2 - 3.75) m/s; the ambient temperature is ranged between (โˆ’12.9 - 4.03); the solar irradiance is ranged between (โˆ’3.84 - 994) W/m2 . Generally, when the solar irradiance witnesses a significant increase, the instantaneous value of the efficiency is reduced, particularly, when the solar (a) 6 8 10 12 14 16 18 20 -20 0 20 40 60 T i m e ( h ) T e m p e r a t u r e o C 6 8 10 12 14 16 18 20 11 12 13 14 15 E f f i c i e n c y Ambient Pv Temp Efficienc
  • 8. Y. I. A. Osman et al. DOI: 10.4236/sgre.2018.97008 120 Smart Grid and Renewable Energy (b) (c) (d) (e) (f) (g) Figure 3. Ambient temperature, PV surface temperature, and the efficiency as a function of day hours for the entire week. (a) 1st day; (b) 2nd day; (c) 3rd day; (d) 4th day; (e) 5th day; (f) 6th day. irradiance exceeds 800 W/m2 , this due to the considerable increase of the pho- tovoltaic surface temperature as shown in Figure 5. 6. Conclusions In this paper the influences of the environmental factors such as solar radiation, wind speed, and ambient temperature on the house-hold PV panel efficiency are 6 8 10 12 14 16 18 20 -20 0 20 40 T i m e ( h ) T e m p e r a t u r e o C 6 8 10 12 14 16 18 20 12 13 14 15 E f f i c i e n c y Ambient Pv Temp Efficienc 6 8 10 12 14 16 18 20 -20 0 20 40 T i m e ( h ) T e m p e r a t u r e o C 6 8 10 12 14 16 18 20 10 12 14 16 E f f i c i e n c y Ambient Pv Temp Efficienc 6 8 10 12 14 16 18 20 -20 0 20 40 T i m e ( h ) T e m p e r a t u r e o C 6 8 10 12 14 16 18 20 12 13 14 15 E f f i c i e n c y Ambient Pv Temp Efficienc 6 8 10 12 14 16 18 20 -20 0 20 40 60 T i m e ( h ) T e m p e r a t u r e o C 6 8 10 12 14 16 18 20 11 12 13 14 15 E f f i c i e n c y Ambient Pv Temp Efficienc 6 8 10 12 14 16 18 20 -20 0 20 40 T i m e ( h ) T e m p e r a t u r e o C 6 8 10 12 14 16 18 20 10 12 14 16 E f f i c i e n c y Ambient Pv Temp Efficiency 6 8 10 12 14 16 18 20 -10 0 10 20 30 40 T i m e ( h ) T e m p e r a t u r e o C 6 8 10 12 14 16 18 20 12 12.5 13 13.5 14 14.5 E f f i c i e n c y Ambient Pv Temp Efficienc
  • 9. Y. I. A. Osman et al. DOI: 10.4236/sgre.2018.97008 121 Smart Grid and Renewable Energy Table 3. Statistical values of ambient temperature and PV surface temperature. Ambient temperature PV temperature Days min max mean min max mean โˆ’12.9 4.03 โˆ’1.93 โˆ’12.7 45.16 19.11 1th โˆ’10.5 โˆ’1.36 โˆ’5.77 โˆ’10.4 31.80 0.99 2th โˆ’13.2 โˆ’3.41 โˆ’6.22 โˆ’13.2 37.28 12.95 3th โˆ’7.68 โˆ’0.13 โˆ’3.11 โˆ’7.68 27.38 2.57 4th โˆ’10.7 โˆ’0.67 โˆ’4.21 โˆ’10.6 42.73 11.19 5th โˆ’14.6 โˆ’2.18 โˆ’6.01 โˆ’14.4 38.13 14.62 6th โˆ’9.02 5.93 1.31 โˆ’8.97 31.58 9.62 7th Figure 4. The plots of the efficiency as a function of PV surface temperature of (9 Feb. 2015-15 Feb. 2015). investigated and quantified. Based on the experimental results, the house-hold PV panel performance is considerably varied. This deviation is ranged between 11.39% - 14.75%. The house-hold PV panel performance is basically affected by the PV surface temperature, therefore, multilevel of energy is detected. Approximately, 3% effi- ciency variation is detected. This investigation is exclusively considered solar radiation, wind speed, and ambient temperature as an environmental factor, and future work should asso- ciate other factors such as humidity, rainfall, seasonal variation. Investigating and analyzing the influence of the environmental factors on the -20 0 20 40 60 10 15 PV Temperature o C 1th day Efficiency (%) -20 -10 0 10 20 30 40 12 14 16 PV Temperature o C 2th day Efficiency (%) -20 -10 0 10 20 30 40 10 15 PV Temperature o C 3th day Efficiency (%) -10 0 10 20 30 12 14 16 PV Temperature o C 4th day Efficiency (%) -20 0 20 40 60 10 15 PV Temperature o C 5th day Efficiency (%) -20 -10 0 10 20 30 40 10 15 PV Temperature o C 6th day Efficiency (%) -10 0 10 20 30 40 12 14 16 PV Temperature o C 7th day Efficiency (%)
  • 10. Y. I. A. Osman et al. DOI: 10.4236/sgre.2018.97008 122 Smart Grid and Renewable Energy Figure 5. The plots of the efficiency as a function of solar radiation of (9 Feb. 2015-15 Feb. 2015). house-hold PV panel facilitate the process of assessment and prediction of per- formance and the harvested power and thus accurately size the PV plants. Conflicts of Interest The authors declare no conflicts of interest regarding the publication of this pa- per. References [1] Honrubia-Escribano, A., et al. (2018) Influence of Solar Technology in the Eco- nomic Performance of PV Power Plants in Europe: A Comprehensive Analysis. Re- newable and Sustainable Energy Reviews, 82, 488-501. https://doi.org/10.1016/j.rser.2017.09.061 [2] Obeidat, F. (2018) A Comprehensive Review of Future Photovoltaic Systems. Solar Energy, 163, 545-551. https://doi.org/10.1016/j.solener.2018.01.050 [3] Bai, A., et al. (2016) Technical and Economic Effects of Cooling of Monocrystalline Photovoltaic Modules under Hungarian Conditions. Renewable and Sustainable Energy Reviews, 60, 1086-1099. https://doi.org/10.1016/j.rser.2016.02.003 [4] Ndiaye, A., et al. (2014) Degradation Evaluation of Crystalline-Silicon Photovoltaic Modules after a Few Operation Years in a Tropical Environment. Solar Energy, 103, 70-77. https://doi.org/10.1016/j.solener.2014.02.006 [5] Kahoul, N., Houabes, M. and Sadok, M. (2014) Assessing the Early Degradation of Photovoltaic Modules Performance in the Saharan Region. Energy Conversion and Management, 82, 320-326. https://doi.org/10.1016/j.enconman.2014.03.034 [6] Sen, R. and Bhattacharyya, S.C. (2014) Off-Grid Electricity Generation with Re- -200 0 200 400 600 800 1000 10 12 14 16 Solar irradiance W/m2 1th day Efficiency (%) -200 0 200 400 600 800 1000 12 13 14 15 Solar irradiance W/m2 2th day Efficiency (%) -200 0 200 400 600 800 1000 10 12 14 16 Solar irradiance W/m2 3th day Efficiency (%) -200 0 200 400 600 800 1000 12 13 14 15 Solar irradiance W/m2 4th day Efficiency (%) -200 0 200 400 600 800 1000 1200 10 12 14 16 Solar irradiance W/m2 5th day Efficiency (%) -200 0 200 400 600 800 1000 10 12 14 16 Solar irradiance W/m2 6th day Efficiency (%) -200 0 200 400 600 800 1000 12 13 14 15 Solar irradiance W/m2 7th day Efficiency (%)
  • 11. Y. I. A. Osman et al. DOI: 10.4236/sgre.2018.97008 123 Smart Grid and Renewable Energy newable Energy Technologies in India: An Application of HOMER. Renewable Energy, 62, 388-398. https://doi.org/10.1016/j.renene.2013.07.028 [7] Sieminski, A. (2014) International Energy Outlook. Energy Information Adminis- tration (EIA), 18. [8] Outlook, A.E. (2010) International Energy Outlook. 92010, Energy Information Administration, Department of Energy, 1-15. [9] Touati, F., et al. (2016) Investigation of Solar PV Performance under Doha Weather Using a Customized Measurement and Monitoring System. Renewable Energy, 89, 564-577. https://doi.org/10.1016/j.renene.2015.12.046 [10] Bendib, B., Belmili, H. and Krim, F. (2015) A Survey of the Most Used MPPT Me- thods: Conventional and Advanced Algorithms Applied for Photovoltaic Systems. Renewable and Sustainable Energy Reviews, 45, 637-648. https://doi.org/10.1016/j.rser.2015.02.009 [11] Skoplaki, E. and Palyvos, J. (2009) Operating Temperature of Photovoltaic Modules: A Survey of Pertinent Correlations. Renewable Energy, 34, 23-29. https://doi.org/10.1016/j.renene.2008.04.009 [12] Alami, A.H. (2014) Effects of Evaporative Cooling on Efficiency of Photovoltaic Modules. Energy Conversion and Management, 77, 668-679. https://doi.org/10.1016/j.enconman.2013.10.019 [13] Niลพetiฤ‡, S., et al. (2016) Water Spray Cooling Technique Applied on a Photovoltaic Panel: The Performance Response. Energy Conversion and Management, 108, 287-296. https://doi.org/10.1016/j.enconman.2015.10.079 [14] Polo, J., Fernandez-Neira, W. and Alonso-Garcรญa, M. (2017) On the Use of Refer- ence Modules as Irradiance Sensor for Monitoring and Modelling Rooftop PV Sys- tems. Renewable Energy, 106, 186-191. https://doi.org/10.1016/j.renene.2017.01.026 [15] Yang, D. (2017) On Adding and Removing Sensors in a Solar Irradiance Monitor- ing Network for Areal Forecasting and PV System Performance Evaluation. Solar Energy, 155, 1417-1430. https://doi.org/10.1016/j.solener.2017.07.061 [16] Abdolzadeh, M. and Ameri, M. (2009) Improving the Effectiveness of a Photovol- taic Water Pumping System by Spraying Water over the Front of Photovoltaic Cells. Renewable Energy, 34, 91-96. https://doi.org/10.1016/j.renene.2008.03.024 [17] Habiballahi, M., Ameri, M. and Mansouri, S. (2015) Efficiency Improvement of Photovoltaic Water Pumping Systems by Means of Water Flow Beneath Photovol- taic Cells Surface. Journal of Solar Energy Engineering, 137, Article ID: 044501. https://doi.org/10.1115/1.4029932 [18] Aelenei, L., et al. (2014) Thermal Performance of a Hybrid BIPV-PCM: Modeling, Design and Experimental Investigation. Energy Procedia, 48, 474-483. https://doi.org/10.1016/j.egypro.2014.02.056 [19] Ibrahim, H. and Anani, N. (2017) Variations of PV Module Parameters with Irra- diance and Temperature. Energy Procedia, 134, 276-285. https://doi.org/10.1016/j.egypro.2017.09.617 [20] Elbreki, A., et al. (2017) Towards Adopting Passive Heat Dissipation Approaches for Temperature Regulation of PV Module as a Sustainable Solution. Renewable and Sustainable Energy Reviews, 69, 961-1017. https://doi.org/10.1016/j.rser.2016.09.054 [21] Bouraiou, A., et al. (2018) Experimental Investigation of Observed Defects in Crys- talline Silicon PV Modules under Outdoor Hot Dry Climatic Conditions in Algeria. Solar Energy, 159, 475-487. https://doi.org/10.1016/j.solener.2017.11.018
  • 12. Y. I. A. Osman et al. DOI: 10.4236/sgre.2018.97008 124 Smart Grid and Renewable Energy [22] Masuko, K., et al. (2014) Achievement of More Than 25% Conversion Efficiency with Crystalline Silicon Heterojunction Solar Cell. IEEE Journal of Photovoltaics, 4, 1433-1435. https://doi.org/10.1109/JPHOTOV.2014.2352151 [23] Kazem, H.A. and Chaichan, M.T. (2016) Experimental Analysis of the Effect of Dustโ€™s Physical Properties on Photovoltaic Modules in Northern Oman. Solar Energy, 139, 68-80. https://doi.org/10.1016/j.solener.2016.09.019 [24] Kankiewicz, A., Sengupta, M. and Moon, D. (2010) Observed Impacts of Transient Clouds on Utility-Scale PV Fields. Proceedings of ASES National Solar Conference, Phoenix, Arizona, USA, 17-22 May 2010. [25] Curtright, A.E. and Apt, J. (2008) The Character of Power Output from Utility-Scale Photovoltaic Systems. Progress in Photovoltaics: Research and Applications, 16, 241-247. https://doi.org/10.1002/pip.786 [26] Li, N., Liu, C. and Zha, D. (2016) Performance Evaluation of Chinese Photovoltaic Companies with the Input-Oriented Dynamic SBM Model. Renewable Energy, 89, 489-497. https://doi.org/10.1016/j.renene.2015.12.028 [27] Azadeh, A., Ghaderi, S. and Maghsoudi, A. (2008) Location Optimization of Solar Plants by an Integrated Hierarchical DEA PCA Approach. Energy Policy, 36, 3993-4004. https://doi.org/10.1016/j.enpol.2008.05.034 [28] Sueyoshi, T. and Goto, M. (2014) Photovoltaic Power Stations in Germany and the United States: A Comparative Study by Data Envelopment Analysis. Energy Eco- nomics, 42, 271-288. https://doi.org/10.1016/j.eneco.2014.01.004 [29] Garcรญa-Domingo, B., et al. (2014) Modelling the Influence of Atmospheric Condi- tions on the Outdoor Real Performance of a CPV (Concentrated Photovoltaic) Module. Energy, 70, 239-250. https://doi.org/10.1016/j.energy.2014.03.119 [30] Nishioka, K., et al. (2003) Field-Test Analysis of PV System Output Characteristics Focusing on Module Temperature. Solar Energy Materials and Solar Cells, 75, 665-671. https://doi.org/10.1016/S0927-0248(02)00148-4 [31] Al-Shamani, A.N., et al. (2014) Nanofluids for Improved Efficiency in Cooling Solar Collectorsโ€”A Review. Renewable and Sustainable Energy Reviews, 38, 348-367. https://doi.org/10.1016/j.rser.2014.05.041 [32] McColl, S.J., Rodgers, P. and Eveloy, V. (2015) Thermal Management of Solar Pho- tovoltaics Modules for Enhanced Power Generation. Renewable Energy, 82, 14-20. https://doi.org/10.1016/j.renene.2014.09.015 [33] Gรถkmen, N., et al. (2016) Investigation of Wind Speed Cooling Effect on PV Panels in Windy Locations. Renewable Energy, 90, 283-290. https://doi.org/10.1016/j.renene.2016.01.017 [34] Obara, S.Y., et al. (2014) Output Prediction of Large-Scale Photovoltaics by Wind-Condition Analysis Using 3D Topographic Maps. Solar Energy, 105, 157-169. https://doi.org/10.1016/j.solener.2014.03.007 [35] Schwingshackl, C., et al. (2013) Wind Effect on PV Module Temperature: Analysis of Different Techniques for an Accurate Estimation. Energy Procedia, 40, 77-86. https://doi.org/10.1016/j.egypro.2013.08.010 [36] Koehl, M., et al. (2011) Modeling of the Nominal Operating Cell Temperature Based on Outdoor Weathering. Solar Energy Materials and Solar Cells, 95, 1638-1646. https://doi.org/10.1016/j.solmat.2011.01.020 [37] Gaglia, A.G., et al. (2017) Energy Efficiency of PV Panels under Real Outdoor Con- ditionsโ€“An Experimental Assessment in Athens, Greece. Renewable Energy, 101, 236-243. https://doi.org/10.1016/j.renene.2016.08.051
  • 13. Y. I. A. Osman et al. DOI: 10.4236/sgre.2018.97008 125 Smart Grid and Renewable Energy [38] Migan, G.-A. (2013) Study the Operating Temperature of a PV Module. Project Report. [39] Commission, I.E. (2005) Crystalline Silicon Terrestrial Photovoltaic (PV) Mod- ulesโ€”Design Qualification and Type Approval. International Standard IEC, 61215-04.