This document provides specifications for a 1G 1610nm 80km CWDM SFP transceiver module. Key details include:
- It operates at 1.25Gbps up to 80km on single mode fiber with a 1610nm CWDM laser transmitter.
- Electrical characteristics include a supply voltage of 3.13-3.47V and supply current of up to 220mA.
- Optical characteristics include an average output power of 0-5dBm and receiver sensitivity of -24dBm.
- It has digital diagnostic monitoring interfaces and complies with SFP MSA standards.
Dev Dives: Train smarter, not harder – active learning and UiPath LLMs for do...UiPathCommunity
💥 Speed, accuracy, and scaling – discover the superpowers of GenAI in action with UiPath Document Understanding and Communications Mining™:
See how to accelerate model training and optimize model performance with active learning
Learn about the latest enhancements to out-of-the-box document processing – with little to no training required
Get an exclusive demo of the new family of UiPath LLMs – GenAI models specialized for processing different types of documents and messages
This is a hands-on session specifically designed for automation developers and AI enthusiasts seeking to enhance their knowledge in leveraging the latest intelligent document processing capabilities offered by UiPath.
Speakers:
👨🏫 Andras Palfi, Senior Product Manager, UiPath
👩🏫 Lenka Dulovicova, Product Program Manager, UiPath
Transcript: Selling digital books in 2024: Insights from industry leaders - T...BookNet Canada
The publishing industry has been selling digital audiobooks and ebooks for over a decade and has found its groove. What’s changed? What has stayed the same? Where do we go from here? Join a group of leading sales peers from across the industry for a conversation about the lessons learned since the popularization of digital books, best practices, digital book supply chain management, and more.
Link to video recording: https://bnctechforum.ca/sessions/selling-digital-books-in-2024-insights-from-industry-leaders/
Presented by BookNet Canada on May 28, 2024, with support from the Department of Canadian Heritage.
Connector Corner: Automate dynamic content and events by pushing a buttonDianaGray10
Here is something new! In our next Connector Corner webinar, we will demonstrate how you can use a single workflow to:
Create a campaign using Mailchimp with merge tags/fields
Send an interactive Slack channel message (using buttons)
Have the message received by managers and peers along with a test email for review
But there’s more:
In a second workflow supporting the same use case, you’ll see:
Your campaign sent to target colleagues for approval
If the “Approve” button is clicked, a Jira/Zendesk ticket is created for the marketing design team
But—if the “Reject” button is pushed, colleagues will be alerted via Slack message
Join us to learn more about this new, human-in-the-loop capability, brought to you by Integration Service connectors.
And...
Speakers:
Akshay Agnihotri, Product Manager
Charlie Greenberg, Host
Securing your Kubernetes cluster_ a step-by-step guide to success !KatiaHIMEUR1
Today, after several years of existence, an extremely active community and an ultra-dynamic ecosystem, Kubernetes has established itself as the de facto standard in container orchestration. Thanks to a wide range of managed services, it has never been so easy to set up a ready-to-use Kubernetes cluster.
However, this ease of use means that the subject of security in Kubernetes is often left for later, or even neglected. This exposes companies to significant risks.
In this talk, I'll show you step-by-step how to secure your Kubernetes cluster for greater peace of mind and reliability.
Encryption in Microsoft 365 - ExpertsLive Netherlands 2024Albert Hoitingh
In this session I delve into the encryption technology used in Microsoft 365 and Microsoft Purview. Including the concepts of Customer Key and Double Key Encryption.
GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using Deplo...James Anderson
Effective Application Security in Software Delivery lifecycle using Deployment Firewall and DBOM
The modern software delivery process (or the CI/CD process) includes many tools, distributed teams, open-source code, and cloud platforms. Constant focus on speed to release software to market, along with the traditional slow and manual security checks has caused gaps in continuous security as an important piece in the software supply chain. Today organizations feel more susceptible to external and internal cyber threats due to the vast attack surface in their applications supply chain and the lack of end-to-end governance and risk management.
The software team must secure its software delivery process to avoid vulnerability and security breaches. This needs to be achieved with existing tool chains and without extensive rework of the delivery processes. This talk will present strategies and techniques for providing visibility into the true risk of the existing vulnerabilities, preventing the introduction of security issues in the software, resolving vulnerabilities in production environments quickly, and capturing the deployment bill of materials (DBOM).
Speakers:
Bob Boule
Robert Boule is a technology enthusiast with PASSION for technology and making things work along with a knack for helping others understand how things work. He comes with around 20 years of solution engineering experience in application security, software continuous delivery, and SaaS platforms. He is known for his dynamic presentations in CI/CD and application security integrated in software delivery lifecycle.
Gopinath Rebala
Gopinath Rebala is the CTO of OpsMx, where he has overall responsibility for the machine learning and data processing architectures for Secure Software Delivery. Gopi also has a strong connection with our customers, leading design and architecture for strategic implementations. Gopi is a frequent speaker and well-known leader in continuous delivery and integrating security into software delivery.
DevOps and Testing slides at DASA ConnectKari Kakkonen
My and Rik Marselis slides at 30.5.2024 DASA Connect conference. We discuss about what is testing, then what is agile testing and finally what is Testing in DevOps. Finally we had lovely workshop with the participants trying to find out different ways to think about quality and testing in different parts of the DevOps infinity loop.
Software Delivery At the Speed of AI: Inflectra Invests In AI-Powered QualityInflectra
In this insightful webinar, Inflectra explores how artificial intelligence (AI) is transforming software development and testing. Discover how AI-powered tools are revolutionizing every stage of the software development lifecycle (SDLC), from design and prototyping to testing, deployment, and monitoring.
Learn about:
• The Future of Testing: How AI is shifting testing towards verification, analysis, and higher-level skills, while reducing repetitive tasks.
• Test Automation: How AI-powered test case generation, optimization, and self-healing tests are making testing more efficient and effective.
• Visual Testing: Explore the emerging capabilities of AI in visual testing and how it's set to revolutionize UI verification.
• Inflectra's AI Solutions: See demonstrations of Inflectra's cutting-edge AI tools like the ChatGPT plugin and Azure Open AI platform, designed to streamline your testing process.
Whether you're a developer, tester, or QA professional, this webinar will give you valuable insights into how AI is shaping the future of software delivery.
Kubernetes & AI - Beauty and the Beast !?! @KCD Istanbul 2024Tobias Schneck
As AI technology is pushing into IT I was wondering myself, as an “infrastructure container kubernetes guy”, how get this fancy AI technology get managed from an infrastructure operational view? Is it possible to apply our lovely cloud native principals as well? What benefit’s both technologies could bring to each other?
Let me take this questions and provide you a short journey through existing deployment models and use cases for AI software. On practical examples, we discuss what cloud/on-premise strategy we may need for applying it to our own infrastructure to get it to work from an enterprise perspective. I want to give an overview about infrastructure requirements and technologies, what could be beneficial or limiting your AI use cases in an enterprise environment. An interactive Demo will give you some insides, what approaches I got already working for real.
1. SFP-1G-CWDM-1610-80-T02#151058
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 1 -
1G 1610nm 80km CDWM SFP Transceiver
Specification Revision Record
Date Version Page Revision Description Prepare Approve
20210706 1.0 Zhang S
All right reserved by Guilin GLsun Science and Tech Group Co., LTD. Without written permission,
any unit or individual can’t reproduce, copy or use it for any commercial purpose.
Product 1G 1610nm 80km CDWM SFP Transceiver
Model SFP-1G-CWDM-1610-80
File No. SFP-1G-CWDM-1610-80-T02#151058
Version 1.0
Issuing Date 2021-7-6
- 1 -
2. SFP-1G-CWDM-1610-80-T02#151058
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 2 -
Product Description
SFP-1G-CWDM-1610-80-T02 SFP transceivers are high performance, cost effective modules supporting
data-rate of 1.25Gb/s and 80km transmission distance with SMF. The transceiver consists of three
sections: an uncooled CWDM DFB laser transmitter, a PIN photodiode integrated with a trans-impedance
preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements. The
transceivers are compatible with SFP Multi-Source Agreement (MSA) and SFF-8472. For further
information, please refer to SFP MSA.
Product Feature
Supports bit rates up to1.25Gbps
Duplex LC connector
Hot pluggable SFP footprint
CWDM 1610nm laser transmitter and PIN photo-detector
Applicable for 80Km SMF connection
Low power consumption, < 0.8W
Digital Diagnostic Monitor Interface
Compliant with SFP MSA and SFF-8472
Very low EMI and excellent ESD protection
Operating case temperature: 0 to 70 °C (commercial)
Application
Gigabit Ethernet
WDM systems
Switch to Switch interface
Switched backplane applications
Router/Server interface
Other optical transmission systems
3. SFP-1G-CWDM-1610-80-T02#151058
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 3 -
Functional Diagram
Absolute Maximum Ratings
Parameter Symbol Min Max Unit Note
Supply Voltage Vcc -0.5 4.0 V
Storage Temperature Ts -40 85 °C
Relative Humidity RH 0 85 %
Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the transceiver.
General Operating Characteristic
Parameter Symbol Min Typ Max Unit Note
Supply Voltage Vcc 3.13 3.3 3.47 V
Supply Current Icc 220 mA
Data Rate DR 1.25 Gb/s
Operating Case Temperature Tc 0 70 °C Commercial
4. SFP-1G-CWDM-1610-80-T02#151058
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 4 -
Electrical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃, VCC = 3.13 to 3.47 V)
Optical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃, VCC = 3.13 to 3.47 V)
Parameter Symbol Min. Typ Max. Unit Note
Transmitter
Operating Wavelength λ λ-7.5nm λ λ+7.5nm nm 1
Ave. output power (Enabled) PAVE 0 5 dBm 2
Extinction Ratio ER 9 dB 2
RMS spectral width Δλ 1 nm
Parameter Symbol Min. Typ Max. Unit Note
Transmitter
Differential data input swing VIN,PP 120 820 mVpp 1
Tx Disable Input-High VIH 2.0 Vcc+0.3 V
Tx Disable Input-Low VIL 0 0.8 V
Tx Fault Output-High VOH 2.0 Vcc+0.3 V 2
Tx Fault Output-Low VOL 0 0.5 V 2
Input differential impedance Rin 100 Ω
Receiver
Differential data output swing Vout,pp 300 650 800 mVpp 3
Rx LOS Output-High VROH 2.0 Vcc+0.3 V 2
Rx LOS Output-Low VROL 0 0.8 V 2
Notes:
1. TD+/- are internally AC coupled with 100Ω differential termination inside the module.
2. Tx Fault and Rx LOS are open collector outputs, which should be pulled up with 4.7k to 10kΩ resistors
on the host board. Pull up voltage between 2.0V and Vcc+0.3V.
3. RD+/- outputs are internally AC coupled, and should be terminated with 100Ω (differential) at the user
SERDES.
5. SFP-1G-CWDM-1610-80-T02#151058
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 5 -
Rise/Fall time (20%~80%) Tr/Tf 0.26 ns 3
Dispersion penalty TDP 3.9 dB
Output Optical Eye Compliant with IEEE802.3 z (class 1 laser safety)
Receiver
Operating Wavelength λ 1270 1610 nm
Receiver Sensitivity PSEN1 -24 dBm 4
Overload PAVE -3 dBm 4
LOS Assert Pa -35 dBm
LOS De-assert Pd -25 dBm
LOS Hysteresis Pd-Pa 0.5 dB
Notes
1. λ means 1270nm~1610nm, Total 18 wavelengths, 20nm spacing.
2. Measured at 1.25 Gb/s with PRBS 2 223 – 1NRZ test pattern.
3. Unfiltered, measured with a PRBS223 – 1
test pattern @1.25Gbps
4. Measured at 1.25Gb/s with PRBS 223 – 1
NRZ test pattern for BER < 1x10-12
Pin Definition And Functions
6. SFP-1G-CWDM-1610-80-T02#151058
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 6 -
Pin Symbol Name/Description Notes
1 VeeT Tx ground
2 Tx Fault Tx fault indication, Open Collector Output, active “H” 1
3 Tx Disable LVTTL Input, internal pull-up, Tx disabled on “H” 2
4 MOD-DEF2 2 wire serial interface data input/output (SDA) 3
5 MOD-DEF1 2 wire serial interface clock input (SCL) 3
6 MOD-DEF0 Model present indication 3
7 Rate select No connection
8 LOS Rx loss of signal, Open Collector Output, active “H” 4
9 VeeR Rx ground
10 VeeR Rx ground
11 VeeR Rx ground
12 RD- Inverse received data out 5
13 RD+ Received data out 5
14 VeeR Rx ground
15 VccR Rx power supply
16 VccT Tx power supply
17 VeeT Tx ground
18 TD+ Transmit data in 6
19 TD- Inverse transmit data in 6
20 VeeT Tx ground
Notes:
1. When high, this output indicates a laser fault of some kind. Low indicates normal operation. And
should be pulled up with a 4.7 – 10KΩ resistor on the host board.
2. TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the
module with a 4.7 – 10KΩ resistor. Its states are:
Low (0 – 0.8V): Transmitter on (>0.8, < 2.0V): Undefined
High (2.0V~Vcc+0.3V): Transmitter Disabled Open: Transmitter Disabled
7. SFP-1G-CWDM-1610-80-T02#151058
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 7 -
3. Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10KΩ
resistor on the host board. The pull-up voltage shall be between 2.0V~Vcc+0.3V.
Mod-Def 0 has been grounded by the module to indicate that the module is present
Mod-Def 1 is the clock line of two wire serial interface for serial ID
Mod-Def 2 is the data line of two wire serial interface for serial ID
4. When high, this output indicates loss of signal (LOS). Low indicates normal operation.
5. RD+/-: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which
should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the
module and is thus not required on the host board.
6. D+/-: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω
differential termination inside the module. The AC coupling is done inside the module and is thus not
required on the host board.
Digital Diagnostic Specifications
The SFP-1G-CWDM-1610-80-T02 transceivers can be used in host systems that require
either internally or externally calibrated digital diagnostics.
Parameter Symbol Units Min. Max. Accuracy Note
Transceiver temperature DTemp-E ºC -45 +90 ±5ºC 1
Transceiver supply voltage DVoltage V 2.8 4.0 ±3%
Transmitter bias current DBias mA 2 80 ±10% 2
Transmitter output power DTx-Power dBm -3 +8 ±3dB
Receiver average input power DRx-Power dBm -27 0 ±3dB
Notes:
1.When Operating temp.=0~70 ºC,the range will be min=-5,Max=+75
2.The accuracy of the Tx bias current is 10% of the actual current from the laser driver to the laser
3. Internal/ External Calibration compatible.
8. SFP-1G-CWDM-1610-80-T02#151058
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 8 -
Typical Interface Circuit
Package Dimensions
Wavelength Latch Color
1610nm Brown
Ordering Information
Part Number Description
SFP-1G-CWDM-1610-80
SFP, 1.25G, CWDM, 1610nm, 80Km, 0~70℃,
with Digital Diagnostic Monitor