This document provides specifications for a 1G 1550nm 80km CWDM SFP transceiver. It operates at 1.25Gbps up to 80km on single mode fiber. The transceiver uses an uncooled CWDM laser transmitter, photodiode receiver, and MCU control unit. It complies with SFP MSA standards and supports gigabit Ethernet, WDM systems, and other optical transmission applications. Electrical, optical, mechanical and diagnostic specifications are provided to characterize the performance and interface of the transceiver.
Dev Dives: Train smarter, not harder – active learning and UiPath LLMs for do...UiPathCommunity
💥 Speed, accuracy, and scaling – discover the superpowers of GenAI in action with UiPath Document Understanding and Communications Mining™:
See how to accelerate model training and optimize model performance with active learning
Learn about the latest enhancements to out-of-the-box document processing – with little to no training required
Get an exclusive demo of the new family of UiPath LLMs – GenAI models specialized for processing different types of documents and messages
This is a hands-on session specifically designed for automation developers and AI enthusiasts seeking to enhance their knowledge in leveraging the latest intelligent document processing capabilities offered by UiPath.
Speakers:
👨🏫 Andras Palfi, Senior Product Manager, UiPath
👩🏫 Lenka Dulovicova, Product Program Manager, UiPath
Elevating Tactical DDD Patterns Through Object CalisthenicsDorra BARTAGUIZ
After immersing yourself in the blue book and its red counterpart, attending DDD-focused conferences, and applying tactical patterns, you're left with a crucial question: How do I ensure my design is effective? Tactical patterns within Domain-Driven Design (DDD) serve as guiding principles for creating clear and manageable domain models. However, achieving success with these patterns requires additional guidance. Interestingly, we've observed that a set of constraints initially designed for training purposes remarkably aligns with effective pattern implementation, offering a more ‘mechanical’ approach. Let's explore together how Object Calisthenics can elevate the design of your tactical DDD patterns, offering concrete help for those venturing into DDD for the first time!
Generating a custom Ruby SDK for your web service or Rails API using Smithyg2nightmarescribd
Have you ever wanted a Ruby client API to communicate with your web service? Smithy is a protocol-agnostic language for defining services and SDKs. Smithy Ruby is an implementation of Smithy that generates a Ruby SDK using a Smithy model. In this talk, we will explore Smithy and Smithy Ruby to learn how to generate custom feature-rich SDKs that can communicate with any web service, such as a Rails JSON API.
Connector Corner: Automate dynamic content and events by pushing a buttonDianaGray10
Here is something new! In our next Connector Corner webinar, we will demonstrate how you can use a single workflow to:
Create a campaign using Mailchimp with merge tags/fields
Send an interactive Slack channel message (using buttons)
Have the message received by managers and peers along with a test email for review
But there’s more:
In a second workflow supporting the same use case, you’ll see:
Your campaign sent to target colleagues for approval
If the “Approve” button is clicked, a Jira/Zendesk ticket is created for the marketing design team
But—if the “Reject” button is pushed, colleagues will be alerted via Slack message
Join us to learn more about this new, human-in-the-loop capability, brought to you by Integration Service connectors.
And...
Speakers:
Akshay Agnihotri, Product Manager
Charlie Greenberg, Host
Epistemic Interaction - tuning interfaces to provide information for AI supportAlan Dix
Paper presented at SYNERGY workshop at AVI 2024, Genoa, Italy. 3rd June 2024
https://alandix.com/academic/papers/synergy2024-epistemic/
As machine learning integrates deeper into human-computer interactions, the concept of epistemic interaction emerges, aiming to refine these interactions to enhance system adaptability. This approach encourages minor, intentional adjustments in user behaviour to enrich the data available for system learning. This paper introduces epistemic interaction within the context of human-system communication, illustrating how deliberate interaction design can improve system understanding and adaptation. Through concrete examples, we demonstrate the potential of epistemic interaction to significantly advance human-computer interaction by leveraging intuitive human communication strategies to inform system design and functionality, offering a novel pathway for enriching user-system engagements.
DevOps and Testing slides at DASA ConnectKari Kakkonen
My and Rik Marselis slides at 30.5.2024 DASA Connect conference. We discuss about what is testing, then what is agile testing and finally what is Testing in DevOps. Finally we had lovely workshop with the participants trying to find out different ways to think about quality and testing in different parts of the DevOps infinity loop.
Smart TV Buyer Insights Survey 2024 by 91mobiles.pdf91mobiles
91mobiles recently conducted a Smart TV Buyer Insights Survey in which we asked over 3,000 respondents about the TV they own, aspects they look at on a new TV, and their TV buying preferences.
State of ICS and IoT Cyber Threat Landscape Report 2024 previewPrayukth K V
The IoT and OT threat landscape report has been prepared by the Threat Research Team at Sectrio using data from Sectrio, cyber threat intelligence farming facilities spread across over 85 cities around the world. In addition, Sectrio also runs AI-based advanced threat and payload engagement facilities that serve as sinks to attract and engage sophisticated threat actors, and newer malware including new variants and latent threats that are at an earlier stage of development.
The latest edition of the OT/ICS and IoT security Threat Landscape Report 2024 also covers:
State of global ICS asset and network exposure
Sectoral targets and attacks as well as the cost of ransom
Global APT activity, AI usage, actor and tactic profiles, and implications
Rise in volumes of AI-powered cyberattacks
Major cyber events in 2024
Malware and malicious payload trends
Cyberattack types and targets
Vulnerability exploit attempts on CVEs
Attacks on counties – USA
Expansion of bot farms – how, where, and why
In-depth analysis of the cyber threat landscape across North America, South America, Europe, APAC, and the Middle East
Why are attacks on smart factories rising?
Cyber risk predictions
Axis of attacks – Europe
Systemic attacks in the Middle East
Download the full report from here:
https://sectrio.com/resources/ot-threat-landscape-reports/sectrio-releases-ot-ics-and-iot-security-threat-landscape-report-2024/
UiPath Test Automation using UiPath Test Suite series, part 4DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 4. In this session, we will cover Test Manager overview along with SAP heatmap.
The UiPath Test Manager overview with SAP heatmap webinar offers a concise yet comprehensive exploration of the role of a Test Manager within SAP environments, coupled with the utilization of heatmaps for effective testing strategies.
Participants will gain insights into the responsibilities, challenges, and best practices associated with test management in SAP projects. Additionally, the webinar delves into the significance of heatmaps as a visual aid for identifying testing priorities, areas of risk, and resource allocation within SAP landscapes. Through this session, attendees can expect to enhance their understanding of test management principles while learning practical approaches to optimize testing processes in SAP environments using heatmap visualization techniques
What will you get from this session?
1. Insights into SAP testing best practices
2. Heatmap utilization for testing
3. Optimization of testing processes
4. Demo
Topics covered:
Execution from the test manager
Orchestrator execution result
Defect reporting
SAP heatmap example with demo
Speaker:
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
1. SFP-1G-CWDM-1550-80-T02#151055
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 1 -
1G 1550nm 80km CWDM SFP Transceiver
Specification Revision Record
Date Version Page Revision Description Prepare Approve
20210706 1.0 Zhang S
All right reserved by Guilin GLsun Science and Tech Group Co., LTD. Without written permission,
any unit or individual can’t reproduce, copy or use it for any commercial purpose.
Product 1G 1550nm 80km CWDM SFP Transceiver
Model SFP-1G-CWDM-1550-80
File No. SFP-1G-CWDM-1550-80-T02#151055
Version 1.0
Issuing Date 2021-7-6
- 1 -
2. SFP-1G-CWDM-1550-80-T02#151055
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 2 -
Product Description
SFP-1G-CWDM-1550-80-T02 SFP transceivers are high performance, cost effective modules supporting
data-rate of 1.25Gb/s and 80km transmission distance with SMF. The transceiver consists of three
sections: an uncooled CWDM DFB laser transmitter, a PIN photodiode integrated with a trans-impedance
preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements. The
transceivers are compatible with SFP Multi-Source Agreement (MSA) and SFF-8472. For further
information, please refer to SFP MSA.
Product Feature
Supports bit rates up to1.25Gbps
Duplex LC connector
Hot pluggable SFP footprint
CWDM 1550nm laser transmitter and PIN photo-detector
Applicable for 80Km SMF connection
Low power consumption, < 0.8W
Digital Diagnostic Monitor Interface
Compliant with SFP MSA and SFF-8472
Very low EMI and excellent ESD protection
Operating case temperature: 0 to 70 °C (commercial)
Application
Gigabit Ethernet
WDM systems
Switch to Switch interface
Switched backplane applications
Router/Server interface
Other optical transmission systems
3. SFP-1G-CWDM-1550-80-T02#151055
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 3 -
Functional Diagram
Absolute Maximum Ratings
Parameter Symbol Min Max Unit Note
Supply Voltage Vcc -0.5 4.0 V
Storage Temperature Ts -40 85 °C
Relative Humidity RH 0 85 %
Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the transceiver.
General Operating Characteristic
Parameter Symbol Min Typ Max Unit Note
Supply Voltage Vcc 3.13 3.3 3.47 V
Supply Current Icc 220 mA
Data Rate DR 1.25 Gb/s
Operating Case Temperature Tc 0 70 °C Commercial
4. SFP-1G-CWDM-1550-80-T02#151055
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 4 -
Electrical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃, VCC = 3.13 to 3.47 V)
Optical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃, VCC = 3.13 to 3.47 V)
Parameter Symbol Min. Typ Max. Unit Note
Transmitter
Operating Wavelength λ λ-7.5nm λ λ+7.5nm nm 1
Ave. output power (Enabled) PAVE 0 5 dBm 2
Extinction Ratio ER 9 dB 2
RMS spectral width Δλ 1 nm
Parameter Symbol Min. Typ Max. Unit Note
Transmitter
Differential data input swing VIN,PP 120 820 mVpp 1
Tx Disable Input-High VIH 2.0 Vcc+0.3 V
Tx Disable Input-Low VIL 0 0.8 V
Tx Fault Output-High VOH 2.0 Vcc+0.3 V 2
Tx Fault Output-Low VOL 0 0.5 V 2
Input differential impedance Rin 100 Ω
Receiver
Differential data output swing Vout,pp 300 650 800 mVpp 3
Rx LOS Output-High VROH 2.0 Vcc+0.3 V 2
Rx LOS Output-Low VROL 0 0.8 V 2
Notes:
1. TD+/- are internally AC coupled with 100Ω differential termination inside the module.
2. Tx Fault and Rx LOS are open collector outputs, which should be pulled up with 4.7k to 10kΩ
resistors on the host board. Pull up voltage between 2.0V and Vcc+0.3V.
3. RD+/- outputs are internally AC coupled, and should be terminated with 100Ω (differential) at the user
SERDES.
5. SFP-1G-CWDM-1550-80-T02#151055
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 5 -
Rise/Fall time (20%~80%) Tr/Tf 0.26 ns 3
Dispersion penalty TDP 3.9 dB
Output Optical Eye Compliant with IEEE802.3 z (class 1 laser safety)
Receiver
Operating Wavelength λ 1270 1610 nm
Receiver Sensitivity PSEN1 -24 dBm 4
Overload PAVE -3 dBm 4
LOS Assert Pa -35 dBm
LOS De-assert Pd -25 dBm
LOS Hysteresis Pd-Pa 0.5 dB
Notes
1. λ means 1270nm~1610nm, Total 18 wavelengths, 20nm spacing.
2. Measured at 1.25 Gb/s with PRBS 2 223 – 1NRZ test pattern.
3. Unfiltered, measured with a PRBS223 – 1
test pattern @1.25Gbps
4. Measured at 1.25Gb/s with PRBS 223 – 1
NRZ test pattern for BER < 1x10-12
Pin Definition And Functions
6. SFP-1G-CWDM-1550-80-T02#151055
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 6 -
Pin Symbol Name/Description Notes
1 VeeT Tx ground
2 Tx Fault Tx fault indication, Open Collector Output, active “H” 1
3 Tx Disable LVTTL Input, internal pull-up, Tx disabled on “H” 2
4 MOD-DEF2 2 wire serial interface data input/output (SDA) 3
5 MOD-DEF1 2 wire serial interface clock input (SCL) 3
6 MOD-DEF0 Model present indication 3
7 Rate select No connection
8 LOS Rx loss of signal, Open Collector Output, active “H” 4
9 VeeR Rx ground
10 VeeR Rx ground
11 VeeR Rx ground
12 RD- Inverse received data out 5
13 RD+ Received data out 5
14 VeeR Rx ground
15 VccR Rx power supply
16 VccT Tx power supply
17 VeeT Tx ground
18 TD+ Transmit data in 6
19 TD- Inverse transmit data in 6
20 VeeT Tx ground
Notes:
1. When high, this output indicates a laser fault of some kind. Low indicates normal operation. And should
be pulled up with a 4.7 – 10KΩ resistor on the host board.
2. TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the
module with a 4.7 – 10KΩ resistor. Its states are:
Low (0 – 0.8V): Transmitter on (>0.8, < 2.0V): Undefined
High (2.0V~Vcc+0.3V): Transmitter Disabled Open: Transmitter Disabled
7. SFP-1G-CWDM-1550-80-T02#151055
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 7 -
3. Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10KΩ
resistor on the host board. The pull-up voltage shall be between 2.0V~Vcc+0.3V.
Mod-Def 0 has been grounded by the module to indicate that the module is present
Mod-Def 1 is the clock line of two wire serial interface for serial ID
Mod-Def 2 is the data line of two wire serial interface for serial ID
4. When high, this output indicates loss of signal (LOS). Low indicates normal operation.
5. RD+/-: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which
should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the
module and is thus not required on the host board.
6. D+/-: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω
differential termination inside the module. The AC coupling is done inside the module and is thus not
required on the host board.
Digital Diagnostic Specifications
The SFP-1G-CWDM-1550-80-T02 transceivers can be used in host systems that require
either internally or externally calibrated digital diagnostics.
Parameter Symbol Units Min. Max. Accuracy Note
Transceiver temperature DTemp-E ºC -45 +90 ±5ºC 1
Transceiver supply voltage DVoltage V 2.8 4.0 ±3%
Transmitter bias current DBias mA 2 80 ±10% 2
Transmitter output power DTx-Power dBm -3 +8 ±3dB
Receiver average input power DRx-Power dBm -27 0 ±3dB
Notes:
1.When Operating temp.=0~70 ºC,the range will be min=-5,Max=+75
2.The accuracy of the Tx bias current is 10% of the actual current from the laser driver to the laser
3. Internal/ External Calibration compatible.
8. SFP-1G-CWDM-1550-80-T02#151055
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 8 -
Typical Interface Circuit
Package Dimensions
Wavelength Latch Color
1550nm Yellow
Ordering Information
Part Number Description
SFP-1G-CWDM-1550-80
SFP, 1.25G, CWDM, 1550nm, 80Km, 0~70℃,
with Digital Diagnostic Monitor