This document provides specifications for the SFP-10G-CWDM-1330-10-T02 10G 1330nm 10km CWDM SFP+ transceiver. It operates at wavelengths around 1330nm for transmission over single-mode fiber up to 10km. The transceiver supports data rates of 9.95 to 11.5Gb/s and includes a transmitter laser and receiver photodiode. It allows monitoring of internal temperatures, voltages and optical powers via a digital diagnostic interface for real-time troubleshooting.
Software Delivery At the Speed of AI: Inflectra Invests In AI-Powered QualityInflectra
In this insightful webinar, Inflectra explores how artificial intelligence (AI) is transforming software development and testing. Discover how AI-powered tools are revolutionizing every stage of the software development lifecycle (SDLC), from design and prototyping to testing, deployment, and monitoring.
Learn about:
• The Future of Testing: How AI is shifting testing towards verification, analysis, and higher-level skills, while reducing repetitive tasks.
• Test Automation: How AI-powered test case generation, optimization, and self-healing tests are making testing more efficient and effective.
• Visual Testing: Explore the emerging capabilities of AI in visual testing and how it's set to revolutionize UI verification.
• Inflectra's AI Solutions: See demonstrations of Inflectra's cutting-edge AI tools like the ChatGPT plugin and Azure Open AI platform, designed to streamline your testing process.
Whether you're a developer, tester, or QA professional, this webinar will give you valuable insights into how AI is shaping the future of software delivery.
Encryption in Microsoft 365 - ExpertsLive Netherlands 2024Albert Hoitingh
In this session I delve into the encryption technology used in Microsoft 365 and Microsoft Purview. Including the concepts of Customer Key and Double Key Encryption.
GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using Deplo...James Anderson
Effective Application Security in Software Delivery lifecycle using Deployment Firewall and DBOM
The modern software delivery process (or the CI/CD process) includes many tools, distributed teams, open-source code, and cloud platforms. Constant focus on speed to release software to market, along with the traditional slow and manual security checks has caused gaps in continuous security as an important piece in the software supply chain. Today organizations feel more susceptible to external and internal cyber threats due to the vast attack surface in their applications supply chain and the lack of end-to-end governance and risk management.
The software team must secure its software delivery process to avoid vulnerability and security breaches. This needs to be achieved with existing tool chains and without extensive rework of the delivery processes. This talk will present strategies and techniques for providing visibility into the true risk of the existing vulnerabilities, preventing the introduction of security issues in the software, resolving vulnerabilities in production environments quickly, and capturing the deployment bill of materials (DBOM).
Speakers:
Bob Boule
Robert Boule is a technology enthusiast with PASSION for technology and making things work along with a knack for helping others understand how things work. He comes with around 20 years of solution engineering experience in application security, software continuous delivery, and SaaS platforms. He is known for his dynamic presentations in CI/CD and application security integrated in software delivery lifecycle.
Gopinath Rebala
Gopinath Rebala is the CTO of OpsMx, where he has overall responsibility for the machine learning and data processing architectures for Secure Software Delivery. Gopi also has a strong connection with our customers, leading design and architecture for strategic implementations. Gopi is a frequent speaker and well-known leader in continuous delivery and integrating security into software delivery.
JMeter webinar - integration with InfluxDB and GrafanaRTTS
Watch this recorded webinar about real-time monitoring of application performance. See how to integrate Apache JMeter, the open-source leader in performance testing, with InfluxDB, the open-source time-series database, and Grafana, the open-source analytics and visualization application.
In this webinar, we will review the benefits of leveraging InfluxDB and Grafana when executing load tests and demonstrate how these tools are used to visualize performance metrics.
Length: 30 minutes
Session Overview
-------------------------------------------
During this webinar, we will cover the following topics while demonstrating the integrations of JMeter, InfluxDB and Grafana:
- What out-of-the-box solutions are available for real-time monitoring JMeter tests?
- What are the benefits of integrating InfluxDB and Grafana into the load testing stack?
- Which features are provided by Grafana?
- Demonstration of InfluxDB and Grafana using a practice web application
To view the webinar recording, go to:
https://www.rttsweb.com/jmeter-integration-webinar
Key Trends Shaping the Future of Infrastructure.pdfCheryl Hung
Keynote at DIGIT West Expo, Glasgow on 29 May 2024.
Cheryl Hung, ochery.com
Sr Director, Infrastructure Ecosystem, Arm.
The key trends across hardware, cloud and open-source; exploring how these areas are likely to mature and develop over the short and long-term, and then considering how organisations can position themselves to adapt and thrive.
Securing your Kubernetes cluster_ a step-by-step guide to success !KatiaHIMEUR1
Today, after several years of existence, an extremely active community and an ultra-dynamic ecosystem, Kubernetes has established itself as the de facto standard in container orchestration. Thanks to a wide range of managed services, it has never been so easy to set up a ready-to-use Kubernetes cluster.
However, this ease of use means that the subject of security in Kubernetes is often left for later, or even neglected. This exposes companies to significant risks.
In this talk, I'll show you step-by-step how to secure your Kubernetes cluster for greater peace of mind and reliability.
Smart TV Buyer Insights Survey 2024 by 91mobiles.pdf91mobiles
91mobiles recently conducted a Smart TV Buyer Insights Survey in which we asked over 3,000 respondents about the TV they own, aspects they look at on a new TV, and their TV buying preferences.
Builder.ai Founder Sachin Dev Duggal's Strategic Approach to Create an Innova...Ramesh Iyer
In today's fast-changing business world, Companies that adapt and embrace new ideas often need help to keep up with the competition. However, fostering a culture of innovation takes much work. It takes vision, leadership and willingness to take risks in the right proportion. Sachin Dev Duggal, co-founder of Builder.ai, has perfected the art of this balance, creating a company culture where creativity and growth are nurtured at each stage.
UiPath Test Automation using UiPath Test Suite series, part 3DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 3. In this session, we will cover desktop automation along with UI automation.
Topics covered:
UI automation Introduction,
UI automation Sample
Desktop automation flow
Pradeep Chinnala, Senior Consultant Automation Developer @WonderBotz and UiPath MVP
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
GraphRAG is All You need? LLM & Knowledge GraphGuy Korland
Guy Korland, CEO and Co-founder of FalkorDB, will review two articles on the integration of language models with knowledge graphs.
1. Unifying Large Language Models and Knowledge Graphs: A Roadmap.
https://arxiv.org/abs/2306.08302
2. Microsoft Research's GraphRAG paper and a review paper on various uses of knowledge graphs:
https://www.microsoft.com/en-us/research/blog/graphrag-unlocking-llm-discovery-on-narrative-private-data/
1. SFP-10G-CWDM-1330-10-T02#141032
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 1 -
10G 1330nm 10km CDWM SFP+ Transceiver
Specification Revision Record
Date Version Page Revision Description Prepare Approve
20200601 1.0 Zhang S
All right reserved by Guilin GLsun Science and Tech Group Co., LTD. Without written permission,
any unit or individual can’t reproduce, copy or use it for any commercial purpose.
Product 10G 1330nm 10km CDWM SFP+ Transceiver
Model SFP-10G-CWDM-1330-10-T02
File No. SFP-10G-CWDM-1330-10-T02#141032
Version 1.0
Issuing Date 2020-6-1
- 1 -
2. SFP-10G-CWDM-1330-10-T02#141032
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 2 -
Product Description
SFP-10G-CWDM-1330-10-T02 CWDM DFB 10Gbps SFP+ transceiver is designed to transmit and receive
optical data over single mode optical fiber for link length 10km. This transceiver consists of two sections:
The transmitter section incorporates a CWDM DFB laser. And the receiver section consists of a PIN
photodiode integrated with a TIA. All modules satisfy class I laser safety requirements. Digital diagnostics
functions are available via a 2-wire serial interface, as specified in SFF-8472, which allows real-time
access to device operating parameters such as transceiver temperature, laser bias current, transmitted
optical power, received optical power and transceiver supply voltage.
Product Feature
Supports 9.95 to 11.5Gb/s bit rates
Duplex LC connector
Hot pluggable SFP+ footprint
Uncooled 1330nm DFB transmitter, PIN photo-detector
Applicable for 10km SMF connection
Low power consumption, < 1W
Digital Diagnostic Monitor Interface
Optical interface compliant to IEEE 802.3ae 10GBASE-LR
Electrical interface compliant to SFF-8431
Operating case temperature: 0 to 70 °C (commercial)
Application
10GBASE-LR/LW at 10.3125Gbps
10G Ethernet
Other optical links
Functional Diagram
3. SFP-10G-CWDM-1330-10-T02#141032
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 3 -
Absolute Maximum Ratings
Parameter Symbol Min Max Unit Note
Supply Voltage Vcc -0.5 4.0 V
Storage Temperature Ts -40 85 °C
Relative Humidity RH 0 85 %
Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the transceiver.
General Operating Characteristic
Parameter Symbol Min. Typ Max. Unit Note
Data Rate DR 9.95 10.3125 Gb/s
Supply Voltage Vcc 3.13 3.3 3.47 V
Supply Current Icc 300 mA
Operating Case
Temp.
Tc 0 70
°C
TI -40 85
Electrical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃,VCC = 3.13 to 3.47 V)
Parameter Symbol Min. Typ Max. Unit Note
Transmitter
Differential data
input swing
VIN,PP 180 700 mVpp 1
Transmit Disable
Voltage
VD VCC-0.8 Vcc
V
Transmit Enable
Voltage VEN Vee Vee+0.8
Input differential
impedance
Rin 100 Ω
Receiver
Differential data
output swing Vout,pp 300 850 mVpp 2
Output rise time
and fall time
Tr, Tf 28 2.0 Vcc+0.3 Ps 3
LOS asserted VLOS_F VCC-0.8 Vcc V 4
LOS de-asserted VLOS_N Vee Vee+0.8 V 4
4. SFP-10G-CWDM-1330-10-T02#141032
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 4 -
Note:
1. Connected directly to TX data input pins. AC coupling from pins into laser driver IC.
2. Into 100Ω differential termination.
3. 20 – 80%. Measured with Module Compliance Test Board and OMA test pattern. Use of four 1’s
and four 0’s sequence in the PRBS 9 is an acceptable alternative.
4. LOS is an open collector output. Should be pulled up with 4.7k Ω – 10kΩ on the host board.
Normal operation is logic 0; loss of signal is logic 1.
Optical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃,VCC = 3.13 to 3.47 V)
Parameter Symbol Min. Typ Max. Unit Note
Transmitter
Operating Wavelength λ λ-7.5nm λ λ+7.5nm nm 1
Ave. output power
(Enabled)
PAVE -6 0 dBm 2
Side-Mode
Suppression Ratio
SMSR 30 dB
Extinction Ratio ER 4 5 dB
RMS spectral width Δλ 1 nm
Rise/Fall time
(20%~80%)
Tr/Tf 50 ps
Dispersion penalty TDP 3.2 dB
Relative Intensity
Noise
RIN -128 dB/Hz
Output Optical Eye Compliant with IEEE 0802.3ae
Receiver
Operating Wavelength λ 1260 1620 nm
Receiver Sensitivity PSEN -14.4 dBm 3
Overload PAVE +0.5 dBm
Receiver Reflectance Rrx -12 dB
LOS Assert Pa -30 dBm
LOS De-assert Pd -17 dBm
LOS Hysteresis Pd-Pa 0.5 4 dB
5. SFP-10G-CWDM-1330-10-T02#141032
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 5 -
Notes:
1. The wavelength λ =1270nm~1610nm, Total 18 wavelengths, 20nm spacing
2. Measured at 10.3125b/s with PRBS 231 – 1
NRZ test pattern.
3. Under the ER worst =5, measured at 10.3125 Gb/s with PRBS 231 - 1
NRZ test pattern for BER <
1x10-12
Pin Definition And Functions
Pin Symbol Name/Description
1 VEET [1] Transmitter Ground
2 Tx_FAULT [2] Transmitter Fault
3 Tx_DIS [3] Transmitter Disable. Laser output disabled on high or open
4 SDA [2] 2-wire Serial Interface Data Line
5 SCL [2] 2-wire Serial Interface Clock Line
6 MOD_ABS [4] Module Absent. Grounded within the module
7 RS0 Rate Select 0
8 RX_LOS [2] Loss of Signal indication. Logic 0 indicates normal operation
9 RS1 [5] Rate Select 1
10 VEER [1] Receiver Ground
11 VEER [1] Receiver Ground
12 RD- Receiver Inverted DATA out. AC Coupled
13 RD+ Receiver DATA out. AC Coupled
14 VEER [1] Receiver Ground
6. SFP-10G-CWDM-1330-10-T02#141032
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 6 -
15 VCCR Receiver Power Supply
16 VCCT Transmitter Power Supply
17 VEET [1] Transmitter Ground
18 TD+ Transmitter DATA in. AC Coupled
19 TD- Transmitter Inverted DATA in. AC Coupled
20 VEET [1] Transmitter Ground
Notes:
1. Module circuit ground is isolated from module chassis ground within the module.
2. Should be pulled up with 4.7k – 10k ohms on host board to a voltage between 3.15Vand 3.6V.
3. Tx_Disable is an input contact with a 4.7 kΩ to 10 kΩ pullup to VccT inside the module.
4. Mod_ABS is connected to VeeT or VeeR in the SFP+ module. The host may pull this contact up to
Vcc_Host with a resistor in the range 4.7 kΩ to10 kΩ.Mod_ABS is asserted “High” when the SFP+
module is physically absent from a host slot.
Serial Interface for ID and Digital Diagnostic Monitor
The SFP-10G-CWDM-1330-10-T02 transceiver support the 2-wire serial communication protocol as
defined in the SFP+ MSA. The standard SFP+ serial ID provides access to identification information that
describes the transceiver’s capabilities, standard interfaces, manufacturer, and other information.
Additionally, This SFP+ transceivers provide an enhanced digital diagnostic monitoring interface, which
allows real-time access to device operating parameters such as transceiver temperature, laser bias
current, transmitted optical power, received optical power and transceiver supply voltage. It also defines a
sophisticated system of alarm and warning flags, which alerts end-users when particular operating
parameters are outside of a factory set normal range.
The SFP MSA defines a 256-byte memory map in EEPROM that is accessible over a 2-wire serial
interface at the 8 bit address 1010000X(A0h), so the originally monitoring interface makes use of the 8 bit
address(A2h), so the originally defined serial ID memory map remains unchanged. The structure of the
memory map is shown in Table1.
Table 1. Digital Diagnostic Memory Map (Specific Data Field Descriptions)
7. SFP-10G-CWDM-1330-10-T02#141032
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 7 -
Digital Diagnostic Specifications
The SFP-10G-CWDM-1330-10-T02 transceivers can be used in host systems that require
either internally or externally calibrated digital diagnostics.
Parameter Symbol Units Min. Max. Accuracy Note
Transceiver temperature DTemp-E ºC -45 +90 ±5ºC 1,2
Transceiver supply
voltage DVoltage V 2.8 4.0 ±3%
Transmitter bias current DBias mA 0 127
±10
%
3
Transmitter output power DTx-Power dBm -8 +2 ±2dB
Receiver average input
power
DRx-Power dBm -16 0 ±2dB
Notes:
1. When Operating temp.=0~70 ºC, the range will be min=-5, Max=+75
2. Internally measured
3. The accuracy of the Tx bias current is 10% of the actual current from the laser driver to the laser
Typical Interface Circuit
8. SFP-10G-CWDM-1330-10-T02#141032
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 8 -
Recommended Power Supply Filter
Note:
Inductors with DC resistance of less than 1Ω should be used in order to maintain the required voltage at
the SFP input pin with 3.3V supply voltage. When the recommended supply filtering network is used, hot
plugging of the SFP transceiver module will result in an inrush current of no more than 30 mA greater
than the steady state value.
Package Dimensions
Ordering Information
Part Number Description
SFP-10G-CWDM-1330-10-T02
SFP+, 9.95 to 11.3Gb/s, CWDM, 10km, 0~70℃, with
Digital Diagnostic Monitor