Tomographic non-invasive imaging of C. Elegans worm: LLTech Light-CT™ scannerSample preparation: worms are anesthetized and encapsulated in a gel
 a gel layer is placed between slide and coverslip
 the sample is imaged using standard Light-CT scanner procedureImaging:3Dtomographic resolution: ≈ 1µm, non invasive, non destructive
3D acquisition of whole worm: 2minutes (about 60 images, thickness 1µm), allowing fast 3D optical biopsycoverslipEncapsulated wormsMicroscope slide
Light-CT allows fast identification of anatomy – worm 1Image plane 1 @ 15µm depthImage plane 2 @ 30µm depth800µm800µmCorpuspharynxIsthmusPosterior bulbExcretory canalspermatheca1vulvaeggsovocytesspermatheca2gonad armintestineovocytes
Light-CT allows fast identification of anatomy – worm 2Image plane 1 @ 15µm depthImage plane 2 @ 30µm depth800µm800µmovocytesintestineBody wall - cuticlegonad armuterus
Light-CT allows full volumetric imaging in a few minutesLight-CT image: allows fine separation of structuresStandard microscope imageOptical sectioning:1µm thickness imageLight-CT images at different depths reveal fine structural details
Light-CT allows fast, precise 3D rendering and volume exploration
Images with 40x objectiveMuch higherresolution

LLTech -Imaging C Elegans Worm in 3D with Light-CT

  • 1.
    Tomographic non-invasive imagingof C. Elegans worm: LLTech Light-CT™ scannerSample preparation: worms are anesthetized and encapsulated in a gel
  • 2.
    a gellayer is placed between slide and coverslip
  • 3.
    the sampleis imaged using standard Light-CT scanner procedureImaging:3Dtomographic resolution: ≈ 1µm, non invasive, non destructive
  • 4.
    3D acquisition ofwhole worm: 2minutes (about 60 images, thickness 1µm), allowing fast 3D optical biopsycoverslipEncapsulated wormsMicroscope slide
  • 5.
    Light-CT allows fastidentification of anatomy – worm 1Image plane 1 @ 15µm depthImage plane 2 @ 30µm depth800µm800µmCorpuspharynxIsthmusPosterior bulbExcretory canalspermatheca1vulvaeggsovocytesspermatheca2gonad armintestineovocytes
  • 6.
    Light-CT allows fastidentification of anatomy – worm 2Image plane 1 @ 15µm depthImage plane 2 @ 30µm depth800µm800µmovocytesintestineBody wall - cuticlegonad armuterus
  • 7.
    Light-CT allows fullvolumetric imaging in a few minutesLight-CT image: allows fine separation of structuresStandard microscope imageOptical sectioning:1µm thickness imageLight-CT images at different depths reveal fine structural details
  • 8.
    Light-CT allows fast,precise 3D rendering and volume exploration
  • 9.
    Images with 40xobjectiveMuch higherresolution