This document provides specifications for an FPI 750P generator set including:
- KW/KVA ratings at 50Hz and 60Hz frequencies and 0.8 power factor
- Prime and standby power ratings defined
- Engine model, displacement, speed, cooling details
- Alternator model, voltage, frequency, performance data
- Enclosure details, dimensions, weights
- Controller model and protections included
Heatpulse 8108 rapid thermal processor: Wafer size: 3 to 8 inch capability. Customer will specify the wafer size
Temperature: 400-1100 °C with ERP Pyrometer. Maximum 1250 °C(Not recommend)
Gas lines: 2 gas lines with 2 MFC. N2,O2 or Ar.
Price: Pls email us with your RFQ in detail. Appreciate your time.
Heatpulse 4108 rapid thermal processor:Wafer size: 3 to 8 inch capability. Customer will specify the wafer size . Temperature: 400-1100 °C with ERP Pyrometer. Maximum 1250 °C(Not recommend). Gas lines: 2 gas lines with 2 MFC. N2,O2 or Ar.
Heatpulse 8108 rapid thermal processor: Wafer size: 3 to 8 inch capability. Customer will specify the wafer size
Temperature: 400-1100 °C with ERP Pyrometer. Maximum 1250 °C(Not recommend)
Gas lines: 2 gas lines with 2 MFC. N2,O2 or Ar.
Price: Pls email us with your RFQ in detail. Appreciate your time.
Heatpulse 4108 rapid thermal processor:Wafer size: 3 to 8 inch capability. Customer will specify the wafer size . Temperature: 400-1100 °C with ERP Pyrometer. Maximum 1250 °C(Not recommend). Gas lines: 2 gas lines with 2 MFC. N2,O2 or Ar.
The HiVol 3000 particulate sampler performs remote unattended sampling of PM2.5, PM10 or TSP along with basic meteorological parameters.
The HiVol 3000 incorporates advanced programming functions and electronic volumetric flow control to maintain a consistent flow and collect a truly representative sample of particulate matter.
Optional attachments allow the sampler to measure wind speed and direction which can then be used to trigger sector selectable sampling (e.g. fence-line monitoring).
The HiVol 3000 particulate sampler performs remote unattended sampling of PM2.5, PM10 or TSP along with basic meteorological parameters.
The HiVol 3000 incorporates advanced programming functions and electronic volumetric flow control to maintain a consistent flow and collect a truly representative sample of particulate matter.
Optional attachments allow the sampler to measure wind speed and direction which can then be used to trigger sector selectable sampling (e.g. fence-line monitoring).
Dr. Glatt was a guest editor of the Infectious Diseases Clinic of North America and infectious diseases editor of Dorland's Illustrated Medical Dictionary.
Here is a “Power Energy Datasheet Template“. TDSmaker offer you free Datasheet/ Specsheet/ Techsheet. Visit to ( https://www.tdsmaker.com ) to get start with free template.
1. FPI 750P
Frequency Voltage kVa Kw Kva Kw
50Hz 400 750 600 825 660
60Hz 480 750 600 825 660
the above KW rating are at 0.8 pf
Guarantied within condition equivalent to those specification in ISO 8528-1,ISO 3046-1 and BS 5514-1.
* Prime power rating of the generating set is where a variable load and unlimited hours usage are applied
on the generating set with an Average load factor of 80% of the prime rating over each 24 hours period.
Note: That a 10% overload is availble for 1 hour in every 12 hours operation
** Standby power rating of the generating set is where a variable load limited to an annual usage up to 500
hours is applied, with 300 hours of which may be continous running. Note that no overload is permitted.
Engine Speed
Standby
Prime Power
75% of Prime Power
50% of Prime Power
Cooling Fan Air Flow m3/min (cfm) System designed for ambients up to 35ºC or 50ºC
Grade
Size
Qty
Prime
Standby
Cylinders
Air System
Combustion Air Flow Cm/min(cfm)
Output Power Rating Prime Standby
Switch able speed 1500/1800 rpm
Engine Technical Data
rpm
22.921 litres
1500
1800
Electronic - Digital
Paper Element (Replaceable)
Aspiration
PERKINS 4006-23TAG2A
6 Vertical in-line
Turbocharged and Air-to-Air charge cooled
Engine Make And Model
Air Filter Type
Electrical Starting System
64 M3/min
1/2 TA - Luft
24 volt starter motor, 24 volt 70 amp battery charging alternator with integral voltage regulator and
activating switch
Combustion System
Displacement
Governor
Emissions Regulations
Direct injection
Fuel Filter Type
Fuel System
203 (in full load)
Class A2 Diesel
1500 rpm
210 (173)
209 (157)
211 (121)
213 (83)
Fuel Consumption
l/hr(US gal/hr)
1800 rpm
226 (199)
222 (177)
212 (129)
212 (90)
Lubrication System
Fuel Tank Capacity: Open / Close
Heat Radiation to Room 231 Kw
Lubrication oil filtersLube Oil
Lube Oil Capacity
Oil Pan
Oil FilterTtype
Coolant Capacity
Cooling System
105 litres
Twin thermostats, water pump
Oil Cooling Method
113.4 litres
113.4 litres
Oil cooler with separate filter header
Wet sump with filler and dipstick
Cooling System
Silencer
Max Allowable Backpressure
Exhaust System
Industrial
8"
1
6.9 kpa
Exhaust Gas Flow m³/min (cfm) 180 M3/min
Exhaust Gas Max
Temp
6.9 kpa
50 Hz
555 `c
553 `c
60 Hz
481 `c
489 `c
2. 380 400 415 380 416 440 480
660 660 660 710 710 725 792
528 528 582 568 568 580 634
Xd % 343 343
Xd % 17.5 17.5
Xd % 14 14
1498.3 1748.5
Heig
ht
(mm)
4250
for more features we can use higher controler
Event and Performance Log
Polyester Powder Coated Galvanized Sheet
Tested Single Point Lifting Facility & Forklift Pockets
4 No`s binary inputs charging alternator fault
Fuel & Water Drainage Provision
Controller Make and Model
Generator Protections
over current
over/under frequency phases sequence
DSEController features
Engine Protections
Inputs and Outputs
3 No`s configuration analog inputs 6 No`s binary outputs
Number of Terminals (leads)
Output Voltage
V
KVA
Reactance (f.l.cl.F)
Motor Starting Capability Based
on 30% voltage dip and 0.8 PF (KVA)
Alternator Performance Data
KW
50 Hz 60 Hz
Cooling Air Flow-@50 Hzm³/min (fcm)
Cooling Air Flow-@60 Hzm³/min (fcm)
Alternator Technical Data Stamdford / or LS
Leroy Somer LSA 49.1 M75
4
6
Model Number
No. of Poles
<50
A.V.R & Excitation
Regulation
Ingress Protection
Insulation Class
Total harmonic TGH/THC
TIF
Gen-set Enclosure Specification (Optional)
Enclosure Type
Anticorrosive Protection
DrainageDrainage
R448
±0.5%
IP-23
H
at no load <4%, on load <4%
60 (2118.88)
Acoustic and Weather Proof
Auto mains failure (AMF) applications including remote communication, user configuration and
complete gen-set monitoring and protection, ready for generators with 3 ph 4 wire/3 ph 3 wire/
mono ph
oil pressure fuel level optional
Radiator Water Filling ProvisionRadiator Water Filling Provision
coolant level optional
Engine hours history log
72 (2542.65)
External Emergency Push Button
RAL 2000
Transportation
RAL 9011
Shipping Data
Water Fill
Cable Access
Emergency Stop
Canopy RAL Color
Chassis RAL Color
Type
Dimention
Length (mm)Length (mm)
coolant temprature
over/under voltage over under frequncy
Gen-set text alarm log
Cable Inlet and Outlet Provision
Weight (kg)
6100
Width
(mm)
Width
(mm)
1920 2290