SlideShare a Scribd company logo
Industrial Diesel Generator Set – T16K
50 Hz
Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction
set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit.
Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to
instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield
different results. Data and specifications subject to change without notice.
RATINGS 400 V - 50 Hz
kVA 16
Standby
kWe 12,80
kVA 14,50
Prime
kWe 11,60
GENERAL SPECIFICATIONS
Engine brand MITSUBISHI
Alternator commercial brand KOHLER
Voltage (V) 400/230
Standard Control Panel APM303
Optional control panel APM403
Optional Control Panel M80
Optional control panel Terminal block
Consumption @ 100% load ESP (L/h) 5
Consumption @ 100% load PRP (L/h) 4
Emission level Fuel consumption optimization
Type of Cooling Mechanical driven fan
Performance class G2
GENERATOR SETS RATINGS
Standby Rating Prime Rating
Voltage PH Hz kWe kVA Amps kWe kVA
415/240 3 50 12,80 16 22 11,60 14,50
400/230 3 50 12,80 16 23 11,60 14,50
380/220 3 50 12,80 16 24 11,60 14,50
200/115 3 50 12,80 16 46 11,60 14,50
240 TRI 3 50 12,80 16 38 11,60 14,50
230 TRI 3 50 12,80 16 40 11,60 14,50
220 TRI 3 50 12,80 16 42 11,60 14,50
T16K
220/127 3 50 10,80 13,50 35 9,80 12,30
Benefits & features
KOHLER premium quality
 Design offices using the latest technical innovations
 Modern fully certified factories
 A cutting edge laboratory
 The generating set, its components and a wide range of options
have been fully developed, prototype tested, factory built, and
production tested
KOHLER premium performances
 Optimized and certified sound levels
 Reliable power, even in extreme conditions
 Optimized fuel consumption
 Compact footprint
 Best quality of electricity, high starting and loading capacity,
according to ISO8528-5
 Robust base frames and high-quality enclosures
 Protection of installations and people
 Approved in line with the most stringent standards
Engines
 Premium level engines, in-house or from strong partners
 High power density, small footprint
 Low temperature starting capability
 Long maintenance interval
Alternator
 Provide industry leading motor starting capability
 Made in Europe
 Built with a class H insulation and IP23
Cooling
 A compact and complete solution using a mechanically driven
radiator fan
 Designed or optimized by KOHLER
 High temperature and altitude product capacity available
Base frame and enclosure
 High quality steel with enhanced corrosion resistance
 Highly durable QUALICOAT-certified epoxy paint
 Minimum 1000 hours of resistance to salt spray in accordance
with ISO12944
 Ergonomic access to allow easy maintenance and
connection of the generator
 Robust design optimized for transportation
DIMENSIONS COMPACT VERSION
Length (mm) 1405
Width (mm) 715
Height (mm) 1053
Tank capacity (L) 50
Dry weight (kg) 406
DIMENSIONS SOUNDPROOFED VERSION NA
Type soundproofing NOT AVAILABLE
Length (mm) 1750
Width (mm) 775
Height (mm) 1230
Tank capacity (L) 50
Dry weight (kg) 554
Acoustic pressure level @1m in dB(A) 50Hz
(75% PRP)
72
Acoustic pressure level @7m in dB(A) 50Hz
(75% PRP)
59
Industrial Diesel Generator Set – T16K
50 Hz
Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction
set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit.
Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to
instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield
different results. Data and specifications subject to change without notice.
Engine
General
Engine brand MITSUBISHI
Engine ref. S4L2-SD *
Air inlet system Atmo
Fuel Diesel Fuel
Emission level
Fuel consumption
optimization
Cylinder configuration L
Number of cylinders 4
Displacement (l) 1,76
Bore (mm) * Stroke (mm) 78 * 92
Compression ratio 22 : 1
Speed 50Hz (RPM) 1500
Maximum stand-by power at rated RPM (kW) 15,80
Frequency regulation, steady state (%) +/- 2.5%
Injection Type Indirect
Governor type Mechanical
Air cleaner type, models Dry
Fuel system
Maximum fuel pump flow (l/h) 18
Max head on fuel return line (m) 1,50
Consumption with cooling system
Fuel consumption @ ESP Max Power (l/h) 4,70
Fuel consumption @ PRP Max Power (l/h) 4,40
Fuel consumption @ 75% of PRP Power (l/h) 3,40
Fuel consumption @ 50% of PRP Power (l/h) 2,60
Emissions
Lubrication System
Oil system capacity including filters (l) 5,90
Min. oil pressure (bar) 1
Max. oil pressure (bar) 4
Oil sump capacity (l) 5,40
Oil consumption 100% ESP 50Hz (l/h) 0,03
Air Intake system
Max. intake restriction (mm H2O) 200
Combustion air flow (l/s) 18,20
Exhaust system
PRP ESP
Heat rejection to exhaust (kW) 14
Exhaust gas temperature (°C) 410
Exhaust gas flow (L/s) 48,70
Max. exhaust back pressure (mm H2O) 700
Cooling system
Radiator & Engine capacity (l) 4,90
Fan power 50Hz (kW) 0,70
Fan air flow w/o restriction (m3/s) 0,80
Available restriction on air flow (mm H2O) 10
Type of coolant Glycol-Ethylene
Radiated heat to ambiant (kW) 2
Heat rejection to coolant HT (kW) 14
Outlet coolant temperature (°C) 93
Max coolant temperature, Shutdown (°C) 111
Thermostat begin of opening HT (°C) 82
Thermostat end of opening HT (°C) 95
* Engine reference may be partially modified depending on genset
application, options selected by the customer and lead time required.
Industrial Diesel Generator Set – T16K
50 Hz
Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction
set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit.
Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to
instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield
different results. Data and specifications subject to change without notice.
Alternator Specifications
Alternator commercial brand KOHLER
Kohler Alternator description KH00470T
Number of pole 4
Number of bearing Single Bearing
Technology Brushless
Indication of protection IP23
Insulation class H
Number of wires 12
AVR Regulation Yes
Coupling Direct
Capacity for maintaining short circuit
at 3 ln for 10 s
Yes
Application data
Overspeed (rpm) 2250
Power factor (Cos Phi) 0,80
Voltage regulation at established
rating (+/- %)
1
Wave form : NEMA=TIF <45
Wave form : CEI=FHT <2
Total Harmonic Distortion in no-load
DHT (%)
2,8
Total Harmonic Distortion, on linear
load DHT (%)
2,2
Recovery time (Delta U = 20%
transcient) (ms)
200
Performance datas
Continuous Nominal Rating 40°C
(kVA)
15
Unbalanced load acceptance ratio
(%)
8
Peak motor starting (kVA) based on x% voltage dip power factor at 0.3
Alternator Standard Features
- All models are brushless, rotating-field alternators
- NEMA MG1, IEEE, and ANSI standards compliance for
temperature rise and motor starting
- The AVR voltage regulator provides superior short
circuit capability
- Self-ventilated and dip proof construction
- Superior voltage waveform
Note: See Alternator Data Sheets for alternator application data
and ratings, efficiency curves, voltage dip with motor starting
curves, and short circuit decrement curves.
Industrial Diesel Generator Set – T16K
50 Hz
Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction
set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit.
Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to
instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield
different results. Data and specifications subject to change without notice.
Dimensions compact version
Length (mm) * Width (mm) * Height (mm) 1405 * 715 * 1053
Dry weight (kg) 406
Tank capacity (L) 50
M126 - Dimensions soundproofed version
Length (mm) * Width (mm) * Height (mm) 1750 * 775 * 1230
Dry weight (kg) 554
Tank capacity (L) 50
Acoustic pressure level @1m in dB(A) 50Hz (75% PRP) 72
Sound power level guaranteed (Lwa) 50Hz (75% PRP) 89
Acoustic pressure level @7m in dB(A) 50Hz (75% PRP) 59
Dimensions DW compact version
Length (mm) * Width (mm) * Height (mm) 1797 * 775 * 1214
Dry weight (kg) 470
Tank capacity (L) 93
M126 - Dimensions DW soundproofed version
Length (mm) * Width (mm) * Height (mm) 1797 * 775 * 1391
Dry weight (kg) 633
Tank capacity (L) 93
Acoustic pressure level @1m in dB(A) 50Hz (75% PRP) 71
Sound power level guaranteed (Lwa) 50Hz (75% PRP) 89
Acoustic pressure level @7m in dB(A) 50Hz (75% PRP) 59
Industrial Diesel Generator Set – T16K
50 Hz
Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction
set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit.
Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to
instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield
different results. Data and specifications subject to change without notice.
Basic
terminal block
It is used as a basic terminal block for connecting a control unit. Offers the
following functions:
- emergency stop button
- customer connection terminal block
- CE certified
M80
The M80 is a dual-function control panel. It can be used as a basic terminal block
for connecting a control unit and as an instrument panel with a direct read
facility, with displays giving a global view of your generating set's basic
parameters. Offers the following functions:
- Engine parameters: tachometer, working hours counter, coolant
temperature indicator, oil pressure indicator
- emergency stop button
- customer connection terminal block
- CE certified
APM303
The APM303 is a versatile unit which can be operated in manual or automatic
mode. It offers the following features:
- Measurements: phase-to-neutral and phase-to-phase voltages, fuel
level (In option : active power currents, effective power, power factors,
Kw/h energy meter, oil pressure and coolant temperature levels)
- Supervision: Modbus RTU communication on RS485
- Reports: (In option : 2 configurable reports)
- Safety features: Overspeed, oil pressure, coolant temperatures,
minimum and maximum voltage, minimum and maximum frequency
(Maximum active power P<66kVA)
- Traceability: Stack of 12 stored events
For further information, please refer to the data sheet for the APM303
APM403
BASIC GENERATING SET AND POWER PLANT CONTROL
The APM403 is a versatile control unit which allows operation in manual or
automatic mode
- Measurements : voltage and current
- kW/kWh/kVA power meters
- Standard specifications: Voltmeter, Frequency meter.
- Optional : Battery ammeter.
- J1939 CAN ECU engine control
- Alarms and faults: Oil pressure, Coolant temperature, Overspeed, Start-
up failure, alternator min/max, Emergency stop button.
- Engine parameters: Fuel level, hour counter, battery voltage.
- Optional (standard at 24V): Oil pressure, water temperature.
- Event log/ Management of the last 300 genset events.
- Mains and genset protection
- Clock management
- USB connections, USB Host and PC,
- Communications : RS485 INTERFACE
- ModBUS protocol /SNMP
- Optional : Ethernet, GPRS, remote control, 3G, 4G,
- Websupervisor, SMS, E-mails
Industrial Diesel Generator Set – T16K
50 Hz
Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction
set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit.
Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to
instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield
different results. Data and specifications subject to change without notice.
STANDARD SCOPE OF SUPPLY
All our gensets are fitted with:
- Industrial water cooled DIESEL engine
- Electric starter & charge alternator
- Standard air filter
- Schneider or ABB electric circuit breaker, adapted to the short-circuit current of the generating set
- Single bearing alternator IP 23 T° rise/ insulation to class H/H
- Welded steel base frame with 85% vibration attenuation mounts
- 4 lifting points on the chassis, lifting bar on the top included from 165 kVA ESP or optional
- highly durable QUALICOAT certified epoxy paint
- frame height optimized to allow it to be moved safely by forklift
- enclosure made of new high-quality European steel with enhanced corrosion resistance
- IP 64 locks, made from stainless materials
- enclosures and base frames tested and analyzed by the French Corrosion Institut
- 100% of tanks tested for permeability
- Personal protection ensured by protective grilles on hot and rotating parts
- Separate 9 dB(A) silencer
- Fuel tank welded inside the genset frame
- Retention bund included for gensets up to 110 kVA ESP
- Charged DC starting battery with electrolyte
- Emergency stop button on the outside
- Flexible fuel lines & lub oil drain cock
- Exhaust outlet with flexible and flanges
- User’s manual (1 copy)
- Packing under plastic film
- Delivered with oil and antifreeze liquid
STANDARD DELIVERY
All our gensets are fitted with:
- Industrial water-cooled DIESEL engine
- Electric starter & charge alternator
- Standard air filter
- Electric circuit breaker, adapted to the short-circuit current of the generating set
- Single bearing alternator IP 23 T° rise/ insulation to class H/H
- Welded steel base frame with 85% vibration attenuation mounts
- frame height optimized to allow it to be moved safely by forklift
- enclosure made of new high-quality European steel with enhanced corrosion resistance
- enclosures and base frames tested and analyzed by the French Corrosion Institut
- 100% of tanks tested for permeability
- Personal protection ensured by protective grilles on hot and rotating parts
- Separate 9 dB(A) silencer
- Fuel tank welded inside the genset frame
- Retention bund included for gensets up to 250 kVA ESP
- Charged DC starting battery with electrolyte
- Emergency stop button on the outside
- Flexible fuel lines & lub oil drain cock
- Exhaust outlet with flexible and flanges
- User’s manual (1 copy)
- Packing under plastic film
- Delivered with oil and antifreeze liquid
CODES AND STANDARDS
Engine-generators set is designed and manufactured in facilities certified to standards ISO9001:2015 & ISO14001:2015. The generator sets and
its components are prototype-tested, factory built and production tested and are in compliance with the relevant standards:
- Machinery Directive 2006/42/EC of May 17th 2006
Industrial Diesel Generator Set – T16K
50 Hz
Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction
set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit.
Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to
instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield
different results. Data and specifications subject to change without notice.
- EMC Directive2014/30/UE
- Safety objectives set out in the Low Voltage Directive 2014/35/UE
- EN ISO 8528-13, EN 60034-1, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 55011, EN 1679-1 et EN 60204-1
POWER RATINGS DEFINITION according to ISO8528-1 (2018-02 edition) and ISO-3046-1
Emergency Standby Power (ESP): The standby rating is applicable to varying loads for the duration of a power outage. There is no overload
capability for this rating. Average load factor per 24 hours of operation is <70%.
Prime Power (PRP): At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one
hour within 12 hour of operation. Average load factor per 24 hours of operation is <70%.
Industrial Diesel Generator Set – T16K
50 Hz
Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction
set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit.
Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to
instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield
different results. Data and specifications subject to change without notice.
TERMS OF USE
According to the standard, the nominal power assigned by the genset is given for 25°C Air Intlet Temperature, of a barometric pressure of 100
kPA (100 m A.S.L), and 30% relative humidity. For particular conditions in your installation, refer to the derating table.
WARRANTY INFORMATIONS
Standard Warranty Period:
- for Products in "back-up" service
o 30 months from the date the Product leaves the plant
o 24 months from the Product’s commissioning date
o 1,000 running hours
The warranty expires when one of the above conditions is met.
- for Products in “prime” or "continuous" service (continuous supply of electricity, either in the absence of any normal electricity grid
or to complement the grid),
o 18 months from the date the Product leaves the plant
o 12 months from the Product’s commissioning date
o 2,500 running hours
The warranty expires when one of the above conditions is met.
For more details regarding conditions of application and scope of the warranty please refer to our General “terms & conditions of sales”.

More Related Content

Similar to T16K.pdf

Avp694 6 compressed
Avp694 6 compressedAvp694 6 compressed
Avp694 6 compressed
jhonnyarpi
 
Kohler 125rzg spec_sheet
Kohler 125rzg spec_sheetKohler 125rzg spec_sheet
Kohler 125rzg spec_sheet
Pooja Kamthe
 
Ss 11317131-18321546-144
Ss 11317131-18321546-144Ss 11317131-18321546-144
Ss 11317131-18321546-144
PILARMARTINEZ569125
 
Technical Data Sheet
Technical Data SheetTechnical Data Sheet
Technical Data SheetBrian Nam
 
C175 16 data sheets epd0105-a
C175 16 data sheets epd0105-aC175 16 data sheets epd0105-a
C175 16 data sheets epd0105-a
unexpo
 
Googol qta5400 g1 2000kw 2500kva
Googol qta5400 g1 2000kw 2500kva Googol qta5400 g1 2000kw 2500kva
Googol qta5400 g1 2000kw 2500kva
Mark Wang
 
Googol qta5400 g5 2400kw 3000kva
Googol qta5400 g5 2400kw 3000kva Googol qta5400 g5 2400kw 3000kva
Googol qta5400 g5 2400kw 3000kva
Mark Wang
 
Googol pta780 g1a 200kw 250kva
Googol pta780 g1a 200kw 250kva Googol pta780 g1a 200kw 250kva
Googol pta780 g1a 200kw 250kva
Mark Wang
 
4DES-7; R404A; t0 -5; tc 45.pdf for CS S
4DES-7; R404A; t0 -5; tc 45.pdf for CS S4DES-7; R404A; t0 -5; tc 45.pdf for CS S
4DES-7; R404A; t0 -5; tc 45.pdf for CS S
TedyChriswanda1
 
Engine Brochure.pdf
Engine Brochure.pdfEngine Brochure.pdf
Engine Brochure.pdf
Daniel Donatelli
 

Similar to T16K.pdf (20)

FPI 1000P
FPI 1000PFPI 1000P
FPI 1000P
 
1000REOZM
1000REOZM1000REOZM
1000REOZM
 
FPI 750P
FPI 750PFPI 750P
FPI 750P
 
1800REOZM_8_12b
1800REOZM_8_12b1800REOZM_8_12b
1800REOZM_8_12b
 
G5371
G5371G5371
G5371
 
Avp694 6 compressed
Avp694 6 compressedAvp694 6 compressed
Avp694 6 compressed
 
1600REOZM_8_12b
1600REOZM_8_12b1600REOZM_8_12b
1600REOZM_8_12b
 
Kohler 125rzg spec_sheet
Kohler 125rzg spec_sheetKohler 125rzg spec_sheet
Kohler 125rzg spec_sheet
 
1500REOZM_8_12b
1500REOZM_8_12b1500REOZM_8_12b
1500REOZM_8_12b
 
FPI 660P
FPI 660PFPI 660P
FPI 660P
 
2000REOZM_8_12b (1)
2000REOZM_8_12b (1)2000REOZM_8_12b (1)
2000REOZM_8_12b (1)
 
Ss 11317131-18321546-144
Ss 11317131-18321546-144Ss 11317131-18321546-144
Ss 11317131-18321546-144
 
1250REOZM_8_12b
1250REOZM_8_12b1250REOZM_8_12b
1250REOZM_8_12b
 
Technical Data Sheet
Technical Data SheetTechnical Data Sheet
Technical Data Sheet
 
C175 16 data sheets epd0105-a
C175 16 data sheets epd0105-aC175 16 data sheets epd0105-a
C175 16 data sheets epd0105-a
 
Googol qta5400 g1 2000kw 2500kva
Googol qta5400 g1 2000kw 2500kva Googol qta5400 g1 2000kw 2500kva
Googol qta5400 g1 2000kw 2500kva
 
Googol qta5400 g5 2400kw 3000kva
Googol qta5400 g5 2400kw 3000kva Googol qta5400 g5 2400kw 3000kva
Googol qta5400 g5 2400kw 3000kva
 
Googol pta780 g1a 200kw 250kva
Googol pta780 g1a 200kw 250kva Googol pta780 g1a 200kw 250kva
Googol pta780 g1a 200kw 250kva
 
4DES-7; R404A; t0 -5; tc 45.pdf for CS S
4DES-7; R404A; t0 -5; tc 45.pdf for CS S4DES-7; R404A; t0 -5; tc 45.pdf for CS S
4DES-7; R404A; t0 -5; tc 45.pdf for CS S
 
Engine Brochure.pdf
Engine Brochure.pdfEngine Brochure.pdf
Engine Brochure.pdf
 

Recently uploaded

Bài tập - Tiếng anh 11 Global Success UNIT 1 - Bản HS.doc
Bài tập - Tiếng anh 11 Global Success UNIT 1 - Bản HS.docBài tập - Tiếng anh 11 Global Success UNIT 1 - Bản HS.doc
Bài tập - Tiếng anh 11 Global Success UNIT 1 - Bản HS.doc
daothibichhang1
 
Ec330B Lc Excavator Volvo Service Repair.pdf
Ec330B Lc Excavator Volvo Service Repair.pdfEc330B Lc Excavator Volvo Service Repair.pdf
Ec330B Lc Excavator Volvo Service Repair.pdf
Excavator
 
Antique Plastic Traders Company Profile
Antique Plastic Traders Company ProfileAntique Plastic Traders Company Profile
Antique Plastic Traders Company Profile
Antique Plastic Traders
 
一比一原版(AIS毕业证)奥克兰商学院毕业证成绩单如何办理
一比一原版(AIS毕业证)奥克兰商学院毕业证成绩单如何办理一比一原版(AIS毕业证)奥克兰商学院毕业证成绩单如何办理
一比一原版(AIS毕业证)奥克兰商学院毕业证成绩单如何办理
eygkup
 
What Exactly Is The Common Rail Direct Injection System & How Does It Work
What Exactly Is The Common Rail Direct Injection System & How Does It WorkWhat Exactly Is The Common Rail Direct Injection System & How Does It Work
What Exactly Is The Common Rail Direct Injection System & How Does It Work
Motor Cars International
 
Core technology of Hyundai Motor Group's EV platform 'E-GMP'
Core technology of Hyundai Motor Group's EV platform 'E-GMP'Core technology of Hyundai Motor Group's EV platform 'E-GMP'
Core technology of Hyundai Motor Group's EV platform 'E-GMP'
Hyundai Motor Group
 
Why Is Your BMW X3 Hood Not Responding To Release Commands
Why Is Your BMW X3 Hood Not Responding To Release CommandsWhy Is Your BMW X3 Hood Not Responding To Release Commands
Why Is Your BMW X3 Hood Not Responding To Release Commands
Dart Auto
 
Wondering if Your Mercedes EIS is at Fault Here’s How to Tell
Wondering if Your Mercedes EIS is at Fault Here’s How to TellWondering if Your Mercedes EIS is at Fault Here’s How to Tell
Wondering if Your Mercedes EIS is at Fault Here’s How to Tell
Vic Auto Collision & Repair
 
欧洲杯比赛投注官网-欧洲杯比赛投注官网网站-欧洲杯比赛投注官网|【​网址​🎉ac123.net🎉​】
欧洲杯比赛投注官网-欧洲杯比赛投注官网网站-欧洲杯比赛投注官网|【​网址​🎉ac123.net🎉​】欧洲杯比赛投注官网-欧洲杯比赛投注官网网站-欧洲杯比赛投注官网|【​网址​🎉ac123.net🎉​】
欧洲杯比赛投注官网-欧洲杯比赛投注官网网站-欧洲杯比赛投注官网|【​网址​🎉ac123.net🎉​】
ahmedendrise81
 
What Does the PARKTRONIC Inoperative, See Owner's Manual Message Mean for You...
What Does the PARKTRONIC Inoperative, See Owner's Manual Message Mean for You...What Does the PARKTRONIC Inoperative, See Owner's Manual Message Mean for You...
What Does the PARKTRONIC Inoperative, See Owner's Manual Message Mean for You...
Autohaus Service and Sales
 
Statistics5,c.xz,c.;c.;d.c;d;ssssss.pptx
Statistics5,c.xz,c.;c.;d.c;d;ssssss.pptxStatistics5,c.xz,c.;c.;d.c;d;ssssss.pptx
Statistics5,c.xz,c.;c.;d.c;d;ssssss.pptx
coc7987515756
 
Things to remember while upgrading the brakes of your car
Things to remember while upgrading the brakes of your carThings to remember while upgrading the brakes of your car
Things to remember while upgrading the brakes of your car
jennifermiller8137
 
Why Isn't Your BMW X5's Comfort Access Functioning Properly Find Out Here
Why Isn't Your BMW X5's Comfort Access Functioning Properly Find Out HereWhy Isn't Your BMW X5's Comfort Access Functioning Properly Find Out Here
Why Isn't Your BMW X5's Comfort Access Functioning Properly Find Out Here
Masters European & Gapanese Auto Repair
 
Empowering Limpopo Entrepreneurs Consulting SMEs.pptx
Empowering Limpopo Entrepreneurs  Consulting SMEs.pptxEmpowering Limpopo Entrepreneurs  Consulting SMEs.pptx
Empowering Limpopo Entrepreneurs Consulting SMEs.pptx
Precious Mvulane CA (SA),RA
 
一比一原版(AUT毕业证)奥克兰理工大学毕业证成绩单如何办理
一比一原版(AUT毕业证)奥克兰理工大学毕业证成绩单如何办理一比一原版(AUT毕业证)奥克兰理工大学毕业证成绩单如何办理
一比一原版(AUT毕业证)奥克兰理工大学毕业证成绩单如何办理
mymwpc
 
5 Warning Signs Your BMW's Intelligent Battery Sensor Needs Attention
5 Warning Signs Your BMW's Intelligent Battery Sensor Needs Attention5 Warning Signs Your BMW's Intelligent Battery Sensor Needs Attention
5 Warning Signs Your BMW's Intelligent Battery Sensor Needs Attention
Bertini's German Motors
 
What do the symbols on vehicle dashboard mean?
What do the symbols on vehicle dashboard mean?What do the symbols on vehicle dashboard mean?
What do the symbols on vehicle dashboard mean?
Hyundai Motor Group
 
What Causes 'Trans Failsafe Prog' to Trigger in BMW X5
What Causes 'Trans Failsafe Prog' to Trigger in BMW X5What Causes 'Trans Failsafe Prog' to Trigger in BMW X5
What Causes 'Trans Failsafe Prog' to Trigger in BMW X5
European Service Center
 
Ec460b lc Excavator Volvo Service Repair.pdf
Ec460b lc Excavator Volvo Service Repair.pdfEc460b lc Excavator Volvo Service Repair.pdf
Ec460b lc Excavator Volvo Service Repair.pdf
Excavator
 
Tyre Industrymarket overview with examples of CEAT
Tyre Industrymarket overview with examples of CEATTyre Industrymarket overview with examples of CEAT
Tyre Industrymarket overview with examples of CEAT
kshamashah95
 

Recently uploaded (20)

Bài tập - Tiếng anh 11 Global Success UNIT 1 - Bản HS.doc
Bài tập - Tiếng anh 11 Global Success UNIT 1 - Bản HS.docBài tập - Tiếng anh 11 Global Success UNIT 1 - Bản HS.doc
Bài tập - Tiếng anh 11 Global Success UNIT 1 - Bản HS.doc
 
Ec330B Lc Excavator Volvo Service Repair.pdf
Ec330B Lc Excavator Volvo Service Repair.pdfEc330B Lc Excavator Volvo Service Repair.pdf
Ec330B Lc Excavator Volvo Service Repair.pdf
 
Antique Plastic Traders Company Profile
Antique Plastic Traders Company ProfileAntique Plastic Traders Company Profile
Antique Plastic Traders Company Profile
 
一比一原版(AIS毕业证)奥克兰商学院毕业证成绩单如何办理
一比一原版(AIS毕业证)奥克兰商学院毕业证成绩单如何办理一比一原版(AIS毕业证)奥克兰商学院毕业证成绩单如何办理
一比一原版(AIS毕业证)奥克兰商学院毕业证成绩单如何办理
 
What Exactly Is The Common Rail Direct Injection System & How Does It Work
What Exactly Is The Common Rail Direct Injection System & How Does It WorkWhat Exactly Is The Common Rail Direct Injection System & How Does It Work
What Exactly Is The Common Rail Direct Injection System & How Does It Work
 
Core technology of Hyundai Motor Group's EV platform 'E-GMP'
Core technology of Hyundai Motor Group's EV platform 'E-GMP'Core technology of Hyundai Motor Group's EV platform 'E-GMP'
Core technology of Hyundai Motor Group's EV platform 'E-GMP'
 
Why Is Your BMW X3 Hood Not Responding To Release Commands
Why Is Your BMW X3 Hood Not Responding To Release CommandsWhy Is Your BMW X3 Hood Not Responding To Release Commands
Why Is Your BMW X3 Hood Not Responding To Release Commands
 
Wondering if Your Mercedes EIS is at Fault Here’s How to Tell
Wondering if Your Mercedes EIS is at Fault Here’s How to TellWondering if Your Mercedes EIS is at Fault Here’s How to Tell
Wondering if Your Mercedes EIS is at Fault Here’s How to Tell
 
欧洲杯比赛投注官网-欧洲杯比赛投注官网网站-欧洲杯比赛投注官网|【​网址​🎉ac123.net🎉​】
欧洲杯比赛投注官网-欧洲杯比赛投注官网网站-欧洲杯比赛投注官网|【​网址​🎉ac123.net🎉​】欧洲杯比赛投注官网-欧洲杯比赛投注官网网站-欧洲杯比赛投注官网|【​网址​🎉ac123.net🎉​】
欧洲杯比赛投注官网-欧洲杯比赛投注官网网站-欧洲杯比赛投注官网|【​网址​🎉ac123.net🎉​】
 
What Does the PARKTRONIC Inoperative, See Owner's Manual Message Mean for You...
What Does the PARKTRONIC Inoperative, See Owner's Manual Message Mean for You...What Does the PARKTRONIC Inoperative, See Owner's Manual Message Mean for You...
What Does the PARKTRONIC Inoperative, See Owner's Manual Message Mean for You...
 
Statistics5,c.xz,c.;c.;d.c;d;ssssss.pptx
Statistics5,c.xz,c.;c.;d.c;d;ssssss.pptxStatistics5,c.xz,c.;c.;d.c;d;ssssss.pptx
Statistics5,c.xz,c.;c.;d.c;d;ssssss.pptx
 
Things to remember while upgrading the brakes of your car
Things to remember while upgrading the brakes of your carThings to remember while upgrading the brakes of your car
Things to remember while upgrading the brakes of your car
 
Why Isn't Your BMW X5's Comfort Access Functioning Properly Find Out Here
Why Isn't Your BMW X5's Comfort Access Functioning Properly Find Out HereWhy Isn't Your BMW X5's Comfort Access Functioning Properly Find Out Here
Why Isn't Your BMW X5's Comfort Access Functioning Properly Find Out Here
 
Empowering Limpopo Entrepreneurs Consulting SMEs.pptx
Empowering Limpopo Entrepreneurs  Consulting SMEs.pptxEmpowering Limpopo Entrepreneurs  Consulting SMEs.pptx
Empowering Limpopo Entrepreneurs Consulting SMEs.pptx
 
一比一原版(AUT毕业证)奥克兰理工大学毕业证成绩单如何办理
一比一原版(AUT毕业证)奥克兰理工大学毕业证成绩单如何办理一比一原版(AUT毕业证)奥克兰理工大学毕业证成绩单如何办理
一比一原版(AUT毕业证)奥克兰理工大学毕业证成绩单如何办理
 
5 Warning Signs Your BMW's Intelligent Battery Sensor Needs Attention
5 Warning Signs Your BMW's Intelligent Battery Sensor Needs Attention5 Warning Signs Your BMW's Intelligent Battery Sensor Needs Attention
5 Warning Signs Your BMW's Intelligent Battery Sensor Needs Attention
 
What do the symbols on vehicle dashboard mean?
What do the symbols on vehicle dashboard mean?What do the symbols on vehicle dashboard mean?
What do the symbols on vehicle dashboard mean?
 
What Causes 'Trans Failsafe Prog' to Trigger in BMW X5
What Causes 'Trans Failsafe Prog' to Trigger in BMW X5What Causes 'Trans Failsafe Prog' to Trigger in BMW X5
What Causes 'Trans Failsafe Prog' to Trigger in BMW X5
 
Ec460b lc Excavator Volvo Service Repair.pdf
Ec460b lc Excavator Volvo Service Repair.pdfEc460b lc Excavator Volvo Service Repair.pdf
Ec460b lc Excavator Volvo Service Repair.pdf
 
Tyre Industrymarket overview with examples of CEAT
Tyre Industrymarket overview with examples of CEATTyre Industrymarket overview with examples of CEAT
Tyre Industrymarket overview with examples of CEAT
 

T16K.pdf

  • 1. Industrial Diesel Generator Set – T16K 50 Hz Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit. Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield different results. Data and specifications subject to change without notice. RATINGS 400 V - 50 Hz kVA 16 Standby kWe 12,80 kVA 14,50 Prime kWe 11,60 GENERAL SPECIFICATIONS Engine brand MITSUBISHI Alternator commercial brand KOHLER Voltage (V) 400/230 Standard Control Panel APM303 Optional control panel APM403 Optional Control Panel M80 Optional control panel Terminal block Consumption @ 100% load ESP (L/h) 5 Consumption @ 100% load PRP (L/h) 4 Emission level Fuel consumption optimization Type of Cooling Mechanical driven fan Performance class G2 GENERATOR SETS RATINGS Standby Rating Prime Rating Voltage PH Hz kWe kVA Amps kWe kVA 415/240 3 50 12,80 16 22 11,60 14,50 400/230 3 50 12,80 16 23 11,60 14,50 380/220 3 50 12,80 16 24 11,60 14,50 200/115 3 50 12,80 16 46 11,60 14,50 240 TRI 3 50 12,80 16 38 11,60 14,50 230 TRI 3 50 12,80 16 40 11,60 14,50 220 TRI 3 50 12,80 16 42 11,60 14,50 T16K 220/127 3 50 10,80 13,50 35 9,80 12,30 Benefits & features KOHLER premium quality  Design offices using the latest technical innovations  Modern fully certified factories  A cutting edge laboratory  The generating set, its components and a wide range of options have been fully developed, prototype tested, factory built, and production tested KOHLER premium performances  Optimized and certified sound levels  Reliable power, even in extreme conditions  Optimized fuel consumption  Compact footprint  Best quality of electricity, high starting and loading capacity, according to ISO8528-5  Robust base frames and high-quality enclosures  Protection of installations and people  Approved in line with the most stringent standards Engines  Premium level engines, in-house or from strong partners  High power density, small footprint  Low temperature starting capability  Long maintenance interval Alternator  Provide industry leading motor starting capability  Made in Europe  Built with a class H insulation and IP23 Cooling  A compact and complete solution using a mechanically driven radiator fan  Designed or optimized by KOHLER  High temperature and altitude product capacity available Base frame and enclosure  High quality steel with enhanced corrosion resistance  Highly durable QUALICOAT-certified epoxy paint  Minimum 1000 hours of resistance to salt spray in accordance with ISO12944  Ergonomic access to allow easy maintenance and connection of the generator  Robust design optimized for transportation DIMENSIONS COMPACT VERSION Length (mm) 1405 Width (mm) 715 Height (mm) 1053 Tank capacity (L) 50 Dry weight (kg) 406 DIMENSIONS SOUNDPROOFED VERSION NA Type soundproofing NOT AVAILABLE Length (mm) 1750 Width (mm) 775 Height (mm) 1230 Tank capacity (L) 50 Dry weight (kg) 554 Acoustic pressure level @1m in dB(A) 50Hz (75% PRP) 72 Acoustic pressure level @7m in dB(A) 50Hz (75% PRP) 59
  • 2. Industrial Diesel Generator Set – T16K 50 Hz Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit. Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield different results. Data and specifications subject to change without notice. Engine General Engine brand MITSUBISHI Engine ref. S4L2-SD * Air inlet system Atmo Fuel Diesel Fuel Emission level Fuel consumption optimization Cylinder configuration L Number of cylinders 4 Displacement (l) 1,76 Bore (mm) * Stroke (mm) 78 * 92 Compression ratio 22 : 1 Speed 50Hz (RPM) 1500 Maximum stand-by power at rated RPM (kW) 15,80 Frequency regulation, steady state (%) +/- 2.5% Injection Type Indirect Governor type Mechanical Air cleaner type, models Dry Fuel system Maximum fuel pump flow (l/h) 18 Max head on fuel return line (m) 1,50 Consumption with cooling system Fuel consumption @ ESP Max Power (l/h) 4,70 Fuel consumption @ PRP Max Power (l/h) 4,40 Fuel consumption @ 75% of PRP Power (l/h) 3,40 Fuel consumption @ 50% of PRP Power (l/h) 2,60 Emissions Lubrication System Oil system capacity including filters (l) 5,90 Min. oil pressure (bar) 1 Max. oil pressure (bar) 4 Oil sump capacity (l) 5,40 Oil consumption 100% ESP 50Hz (l/h) 0,03 Air Intake system Max. intake restriction (mm H2O) 200 Combustion air flow (l/s) 18,20 Exhaust system PRP ESP Heat rejection to exhaust (kW) 14 Exhaust gas temperature (°C) 410 Exhaust gas flow (L/s) 48,70 Max. exhaust back pressure (mm H2O) 700 Cooling system Radiator & Engine capacity (l) 4,90 Fan power 50Hz (kW) 0,70 Fan air flow w/o restriction (m3/s) 0,80 Available restriction on air flow (mm H2O) 10 Type of coolant Glycol-Ethylene Radiated heat to ambiant (kW) 2 Heat rejection to coolant HT (kW) 14 Outlet coolant temperature (°C) 93 Max coolant temperature, Shutdown (°C) 111 Thermostat begin of opening HT (°C) 82 Thermostat end of opening HT (°C) 95 * Engine reference may be partially modified depending on genset application, options selected by the customer and lead time required.
  • 3. Industrial Diesel Generator Set – T16K 50 Hz Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit. Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield different results. Data and specifications subject to change without notice. Alternator Specifications Alternator commercial brand KOHLER Kohler Alternator description KH00470T Number of pole 4 Number of bearing Single Bearing Technology Brushless Indication of protection IP23 Insulation class H Number of wires 12 AVR Regulation Yes Coupling Direct Capacity for maintaining short circuit at 3 ln for 10 s Yes Application data Overspeed (rpm) 2250 Power factor (Cos Phi) 0,80 Voltage regulation at established rating (+/- %) 1 Wave form : NEMA=TIF <45 Wave form : CEI=FHT <2 Total Harmonic Distortion in no-load DHT (%) 2,8 Total Harmonic Distortion, on linear load DHT (%) 2,2 Recovery time (Delta U = 20% transcient) (ms) 200 Performance datas Continuous Nominal Rating 40°C (kVA) 15 Unbalanced load acceptance ratio (%) 8 Peak motor starting (kVA) based on x% voltage dip power factor at 0.3 Alternator Standard Features - All models are brushless, rotating-field alternators - NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting - The AVR voltage regulator provides superior short circuit capability - Self-ventilated and dip proof construction - Superior voltage waveform Note: See Alternator Data Sheets for alternator application data and ratings, efficiency curves, voltage dip with motor starting curves, and short circuit decrement curves.
  • 4. Industrial Diesel Generator Set – T16K 50 Hz Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit. Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield different results. Data and specifications subject to change without notice. Dimensions compact version Length (mm) * Width (mm) * Height (mm) 1405 * 715 * 1053 Dry weight (kg) 406 Tank capacity (L) 50 M126 - Dimensions soundproofed version Length (mm) * Width (mm) * Height (mm) 1750 * 775 * 1230 Dry weight (kg) 554 Tank capacity (L) 50 Acoustic pressure level @1m in dB(A) 50Hz (75% PRP) 72 Sound power level guaranteed (Lwa) 50Hz (75% PRP) 89 Acoustic pressure level @7m in dB(A) 50Hz (75% PRP) 59 Dimensions DW compact version Length (mm) * Width (mm) * Height (mm) 1797 * 775 * 1214 Dry weight (kg) 470 Tank capacity (L) 93 M126 - Dimensions DW soundproofed version Length (mm) * Width (mm) * Height (mm) 1797 * 775 * 1391 Dry weight (kg) 633 Tank capacity (L) 93 Acoustic pressure level @1m in dB(A) 50Hz (75% PRP) 71 Sound power level guaranteed (Lwa) 50Hz (75% PRP) 89 Acoustic pressure level @7m in dB(A) 50Hz (75% PRP) 59
  • 5. Industrial Diesel Generator Set – T16K 50 Hz Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit. Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield different results. Data and specifications subject to change without notice. Basic terminal block It is used as a basic terminal block for connecting a control unit. Offers the following functions: - emergency stop button - customer connection terminal block - CE certified M80 The M80 is a dual-function control panel. It can be used as a basic terminal block for connecting a control unit and as an instrument panel with a direct read facility, with displays giving a global view of your generating set's basic parameters. Offers the following functions: - Engine parameters: tachometer, working hours counter, coolant temperature indicator, oil pressure indicator - emergency stop button - customer connection terminal block - CE certified APM303 The APM303 is a versatile unit which can be operated in manual or automatic mode. It offers the following features: - Measurements: phase-to-neutral and phase-to-phase voltages, fuel level (In option : active power currents, effective power, power factors, Kw/h energy meter, oil pressure and coolant temperature levels) - Supervision: Modbus RTU communication on RS485 - Reports: (In option : 2 configurable reports) - Safety features: Overspeed, oil pressure, coolant temperatures, minimum and maximum voltage, minimum and maximum frequency (Maximum active power P<66kVA) - Traceability: Stack of 12 stored events For further information, please refer to the data sheet for the APM303 APM403 BASIC GENERATING SET AND POWER PLANT CONTROL The APM403 is a versatile control unit which allows operation in manual or automatic mode - Measurements : voltage and current - kW/kWh/kVA power meters - Standard specifications: Voltmeter, Frequency meter. - Optional : Battery ammeter. - J1939 CAN ECU engine control - Alarms and faults: Oil pressure, Coolant temperature, Overspeed, Start- up failure, alternator min/max, Emergency stop button. - Engine parameters: Fuel level, hour counter, battery voltage. - Optional (standard at 24V): Oil pressure, water temperature. - Event log/ Management of the last 300 genset events. - Mains and genset protection - Clock management - USB connections, USB Host and PC, - Communications : RS485 INTERFACE - ModBUS protocol /SNMP - Optional : Ethernet, GPRS, remote control, 3G, 4G, - Websupervisor, SMS, E-mails
  • 6. Industrial Diesel Generator Set – T16K 50 Hz Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit. Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield different results. Data and specifications subject to change without notice. STANDARD SCOPE OF SUPPLY All our gensets are fitted with: - Industrial water cooled DIESEL engine - Electric starter & charge alternator - Standard air filter - Schneider or ABB electric circuit breaker, adapted to the short-circuit current of the generating set - Single bearing alternator IP 23 T° rise/ insulation to class H/H - Welded steel base frame with 85% vibration attenuation mounts - 4 lifting points on the chassis, lifting bar on the top included from 165 kVA ESP or optional - highly durable QUALICOAT certified epoxy paint - frame height optimized to allow it to be moved safely by forklift - enclosure made of new high-quality European steel with enhanced corrosion resistance - IP 64 locks, made from stainless materials - enclosures and base frames tested and analyzed by the French Corrosion Institut - 100% of tanks tested for permeability - Personal protection ensured by protective grilles on hot and rotating parts - Separate 9 dB(A) silencer - Fuel tank welded inside the genset frame - Retention bund included for gensets up to 110 kVA ESP - Charged DC starting battery with electrolyte - Emergency stop button on the outside - Flexible fuel lines & lub oil drain cock - Exhaust outlet with flexible and flanges - User’s manual (1 copy) - Packing under plastic film - Delivered with oil and antifreeze liquid STANDARD DELIVERY All our gensets are fitted with: - Industrial water-cooled DIESEL engine - Electric starter & charge alternator - Standard air filter - Electric circuit breaker, adapted to the short-circuit current of the generating set - Single bearing alternator IP 23 T° rise/ insulation to class H/H - Welded steel base frame with 85% vibration attenuation mounts - frame height optimized to allow it to be moved safely by forklift - enclosure made of new high-quality European steel with enhanced corrosion resistance - enclosures and base frames tested and analyzed by the French Corrosion Institut - 100% of tanks tested for permeability - Personal protection ensured by protective grilles on hot and rotating parts - Separate 9 dB(A) silencer - Fuel tank welded inside the genset frame - Retention bund included for gensets up to 250 kVA ESP - Charged DC starting battery with electrolyte - Emergency stop button on the outside - Flexible fuel lines & lub oil drain cock - Exhaust outlet with flexible and flanges - User’s manual (1 copy) - Packing under plastic film - Delivered with oil and antifreeze liquid CODES AND STANDARDS Engine-generators set is designed and manufactured in facilities certified to standards ISO9001:2015 & ISO14001:2015. The generator sets and its components are prototype-tested, factory built and production tested and are in compliance with the relevant standards: - Machinery Directive 2006/42/EC of May 17th 2006
  • 7. Industrial Diesel Generator Set – T16K 50 Hz Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit. Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield different results. Data and specifications subject to change without notice. - EMC Directive2014/30/UE - Safety objectives set out in the Low Voltage Directive 2014/35/UE - EN ISO 8528-13, EN 60034-1, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 55011, EN 1679-1 et EN 60204-1 POWER RATINGS DEFINITION according to ISO8528-1 (2018-02 edition) and ISO-3046-1 Emergency Standby Power (ESP): The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Average load factor per 24 hours of operation is <70%. Prime Power (PRP): At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour within 12 hour of operation. Average load factor per 24 hours of operation is <70%.
  • 8. Industrial Diesel Generator Set – T16K 50 Hz Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit. Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield different results. Data and specifications subject to change without notice. TERMS OF USE According to the standard, the nominal power assigned by the genset is given for 25°C Air Intlet Temperature, of a barometric pressure of 100 kPA (100 m A.S.L), and 30% relative humidity. For particular conditions in your installation, refer to the derating table. WARRANTY INFORMATIONS Standard Warranty Period: - for Products in "back-up" service o 30 months from the date the Product leaves the plant o 24 months from the Product’s commissioning date o 1,000 running hours The warranty expires when one of the above conditions is met. - for Products in “prime” or "continuous" service (continuous supply of electricity, either in the absence of any normal electricity grid or to complement the grid), o 18 months from the date the Product leaves the plant o 12 months from the Product’s commissioning date o 2,500 running hours The warranty expires when one of the above conditions is met. For more details regarding conditions of application and scope of the warranty please refer to our General “terms & conditions of sales”.