Discover the finest Off-grid solar inverters without battery and MPPT solar inverters equipped with power backup solutions at unbeatable prices in India. Embrace the solar revolution today with Enertech UPS, where cutting-edge technology meets affordability. Harness the power of the sun to fuel your energy needs efficiently and sustainably. Visit our website to explore our range of products and take a step towards a greener, more eco-friendly future.
URL: [https://enertechups.com/product/solar-off-grid-inverter]
Top^Clinic ^%[+27785538335__Safe*Women's clinic//Abortion Pills In Harare
Buy Off Grid Solar Inverter & MPPT Solar Inverter in India.pptx
1. SOLA
R HYBRID
PCU
SunMagic Series
AnsweringAll Power Needs
www.enertechups.com
SOLAR HYBRID PCU
SUNMAGIC
Settable Mode
Batteryless Feature
32BitDSP
www.enertechups.com
AnsweringAll Power Needs
SOLAR
HYBRID PCU
ENERGYTHAT
DRIVES FUTURE
SUNMAGIC SERIES
SINGLE PHASE
THREE PHASE
2. 30 Years Experience In Manufacturing And Development
In Cutting Edge Inverter And ConverterTechnology.
Leading Power Solution Provider 35+ Partners Across India 20000+ Esteemed Customers
ABOUT ENERTECH
VISION
T
oenrichourcustomerswithreliable,cleanand interruptfreepowerwithuseofconventionaland
non conventioanal sources.
QUALITYPOLICY
At Enertech UPS Pvt. Ltd.our core purpose is to ensure customer - delight through offering a range of
power electronics products that meetsinternationalstandards of qualityand performancewith emphasis
on user - friendliness and economy as parameters for continual improvement of products as well as our
qualitymanagement systems.
VALUES
We believe in continual improvement for the betterment.
We willnever give up service,we stand with our comitments.
Organization before Self
We have no Place for Non Performers.
Enertech®UPS Pvt. Ltd.is a leading fastmoving
Indian multinational manufacturing company,
providing the nextgeneration technology
products solutions for the Renewable and
Powersectors.
We provide a comprehensive wide range of power management solutions including Solar hybrid Inverter,
Solar UPS, Online UPS, Industrial UPS, Industrial BatteryCharger,StaticFrequencyConverter.With the
in-house R&D setup Enertech strive for constant success in leveraging technological innovation with next
generation patentedtechnology solutions.
Enertech®with its head quarterat Pune was established in the year 1989.All operations are atSigma Level
4.87. The company has purposefully expanded by providing power solutions for IT
,Industrial, Healthcare,
Banking,and Infrastructure over the period and expanded footprints in Africa,T
anzania,Zambia, Cameroon,
Nigeria,Niger,Yemen,Sudan,Zimbabwe, USA.
3. LowestT
CO
Functionality &Performance
Design for10+Y
earsLifetime
VALUE
SERVICES
Over50+ FactoryT
rained
Engineers.
PanIndiaPartsAvailable.
IndustrialLeadingWarrantyT
erms.
Patented T
echnology.
Bidirectional Inverter.
BatteryLessFeatures.
Modular &Flexibilityin Design.
GridUtilization.
BenefitWith Next Generation PatentedTechnology ForYour
Renewable Energy NeedsWith Our Solar Hybrid Inverter
.
DESIGN QUALITY
In House Engineering
Workmanship.
EveryUnitShippedFullyT
ested.
UtilizationofLong Lasting
Component.
Key Design Differentiating Features for Maximum Performance &Reliability
Bidirectional PowerConversionTechnologyWith InbuiltIsolationTransformer
InnovativeMAXIMUM POWER POINTTRACKER(MPPT) SolarPowerConversionTechnology.
1
2
High PerformanceAllDigitalControl
3
4 SunMagicPCU withMultipleCharging SourcesAvailability
5 ParallelingSolar PCU:Load Sharing-SystemFlexibility(Optional)
6 Battery Management
7 Enertech®SunMagic Seriesis compatiblewith Different BatteryTechnologies
8 Battery Less Features
Anti-Islanding IEC 62116&IEC 61727compliance
9
4. POWER CONDITIONING UNIT
ABOUT SUNMAGIC SERIES
SunMagic Solar Hybrid Inverter (PCU) design with its Patented Technology deliveres the Highest Reliabilities
and performance in the industry to go along with the quality that the user are accustomed to when specifying
SunMagic.
GSM / Wi-Fi
UNIQUE FEATURES
IGBTBased
Rectifier
Bidirectional
Inverter
Advanced
Multiple DSP
Support
Multiple Input
Monitoring
Features
Grid Utilization Battery Less
Operation
Flexibility in
Design
5. Possible Operating mode
User Selecting Any Mode From Below Mode IEC61727
Grid Input
Solar
Panel
MPPT
Charger
Bi-directional
Inverter Isolation
Transformer Contactor
Contactor
Priority
1st
SOLARPOWER
2nd
BATTERYSTORAGE
3rd
GRID SUPPLY
Battery
Load
1
2
3
Grid Input
Solar
Panel
MPPT
Charger
Bi-directional
Inverter Isolation
Transformer Contactor
Contactor
Priority
1st
SOLARPOWER
2nd
GRID SUPPLY
3rd
BATTERYSTORAGE
Battery
Load
1
3
2
Grid Input
Solar
Panel
MPPT
Charger
Bi-directional
Inverter Isolation
Transformer Contactor
Contactor
Priority
1st
GRID SUPPLY
2nd
SOLARPOWER
3rd
BATTERYSTORAGE
Battery
Load
2
3
1
Contactor
Grid Input
Solar
Panel
MPPT
Charger
Bi-directional
Inverter Isolation
Transformer Contactor
Priority
AfterFulfilling
batterystorage and
load demand,excess
solar energy harvested
will be exported to grid
withanti islandingprotection
Battery
Load
3
1
2
Solar -> Grid -> Batteries
Solar ->Batteries -> Grid
Grid -> Solar ->Batteries Grid Feed Mode
INVERTING Mode
Grid Input
Solar
Panel
MPPT
Charger
Bi-directional
Inverter Isolation
Transformer Contactor
Contactor
Priority
1st
SOLARPOWER
2nd
BATTERYSTORAGE
Battery
Load
1
2
6. Remote Monitoring Solution
MONITORING ONTHEGO &ATYOUR DESK !!!
Suitable Protocol: RS-232/MODBUS/RS-485
IOTbased monitoring system- to enable customer to monitor critical PCU systems at their
desk or phone. By using remote monitoring equipment at your sites, you'll now have the visibility
you need to monitor and control your Systems.
All PCU systems in a facilityis connected to Enertech®RMS Interfaceto
collect data and transferto network system /cloud to process data
Remote PC ,mobile is configured with RMS Software forPCU monitoring on
the GO and always atyour desk.
Continuous PCU monitoring and
access to data.
Load trend and graphs in your mobile.
Dataon powerfailures in a day /
week /month.
PCU Alerts on email /SMS.
Daily/weekly/monthlyreports
24x7 remote monitoring – Peace of mind.
ConnectivityViaGSM/Wi-fi.
Reportwith pop-up alarms.
BENEFITS
7. * 170 V to 260 V, 1 Phase
upto 4%
Yes
upto 95%
OUtput Current (Amp) 17.5 21 28 34 44 53 70 87 105
Upto 92 %
Dust free, Cool & Dry Environment
Upto 1000 & (1000 to 3000 deviation) *
*
RAL 7016
* with tolerance of 5v
*
*1
.6 %derating per 100 m
(SUNMAGIC |Single Phase |5kVA-30kVA)
8. Surge
Output High, Output Low, , Over Load, Short Cuircuit
Surge
5
380 450 450 450 450 450 450 450 450
580 800 800 800 800 800 800 800 900
520 800 800 800 800 800 800 800 800
84 125 165 175 200 220 296 320 350
Application of Single Phase Solar Hybrid Inverter
Rural Bank Police Station Shop
Institution
Home
ATM Railway Station Microgird Primary
Health Care Center
Farm House Petrol Pump Hospital
#
## Not for Life Support & Mission Critical Application
Updated on 04 October 2021
9. <100
STANDARD SPECIFICATION SUNMAGIC+ 5kVA to 300kVA
INVERTER CAPACITY (kVA) 5 10 15 20 25 30 40 50 60 80 100 120 150 200 250 300
INPUT
Input Voltage Range * 360 VAC to 450 VAC
Nominal Frequency 50 Hz (± 6%)
Input Fault Level 10 kA
upto 4%
Yes
SOLAR
Charger Type MPPT
Max PV Voltage (VOC) 250V 300V 500V 500V 500V 500V/700V 500V/700V 500V/700V 500V/700V 500V/700V 500V/700
V
500V/700V 700V 900V 1200V 1200V
MPPT Voltage Range 120-180V 160-250V 300-450V for 240VDC / 450-600V for 360VDC 800-1100V
No. of MPPT Channel 3 / 2 3 / 2 3 / 2 3 3 3
Max I/P Amps per Channel
(Amps)
52 83 125 83 104 125/83 166/111 208/138 250/166 333/222 138/92 166/111 138 104 104 125
Yes
upto 95%
BATTERY
96 120 120 240 240 240/360 240/360 240/360 240/360 240/360 240/360 240/360 360 480 600 600
Grid Charging Current
Input Power Factor (Grid
Charging)
Near to Unity
Type & No. of Cells Lead Acid / VRLA / Ni-Cd / Lithium
OUTPUT
Load Power Factor 0.8 lag
Output Voltage (Inverter Mode) 415V AC
± 2%
Output Frequency (Free Running) 50 Hz ± 0.5%
Output Waveform Pure Sine Wave
upto 90%
Overload Capacity 125% for 60 Sec, 150% for 5 Sec
Changeover Time (Full Load) 20 msec
Duty
CONFIGURATION
GRID Feed Mode
ENVIRONMENTAL
distance (Ref : ISO 3746)
0 to 40 Deg C Dust free, Cool & Dry Environment
Storage Temperature -10 Deg C to 60 Deg C
Up to 95% (non condensing)
Upto 1000 & ( 1000 to 3000) **
PHYSICAL
Enclosure Thickness Frame 2.0mm & all covers 1.6mm
Cooling Forced Air
Colour RAL 7016 | RAL 9016
Back
Side
* with tolerance of 5v
*
*1
.6 %derating per 100 m
(SUNMAGIC + |Three Phase |5kVA -600kVA)
10. Parameters Displayed
on LCD MIMIC
General Group Input Group Output Group Solar Group
Fault Log DG Group Power Group Inverter
Group
Recent 9 Fault Log
Since Last Reset
Fault PV ON Inverter ON
Grid ON Charger ON
Load on Mains
Message Displayed on LCD
Output Under Voltage
Output Over Current
Output Overload
Short-Circuit
Stand By Mode
Reset
Buzzer Reset (Manual) Overload
Short Circuit
PROTECTIONS
CONNECTIVITY
Monitoring
PFCs
Grid Trip
Inverter Trip
Common Fault
IEC - 61683 : 1999, IEC - 60068-2-1, IEC - 60068-2-2, IEC - 60068- 2-14, IEC - 60068-2-30- As per MNRE Requirement
1 for Electronic Devices, 1 for Electrical
25- 40 kVA : 3 x 25 mm GI (E
45- 150 kVA : 6 x 50 mm GI (E
200- 300 kVA : 6 x 50 mm GI (E
11 W CFL
Gland Plate
5A / 230 VAC
DIMENSIONS (STANDARD/OPTIONAL)
Dimensions (in mm)
5 10 15 20 25 30 40 50 60 80 100 125 150 200 250 300
Width (W) 380 450 450 450 450 450 450 800 800 1100 1100 1100 1565 3315 3315 3315
Depth (D) 580 800 800 800 800 900 900 950 950 800 800 800 850 850 850 850
Height (H) 520 800 800 800 800 800 800 1700 1700 1800 1900 1900 1900 1900 1900 1900
84 175 200 296 320 350 390 1120 1120 1184 1480 1150 1500 1200 1200 1300
Updated on 04 October 2021
#
## Not for Life Support & Mission Critical Application
11. Application of Solar Hybrid Inverter
Primary
Health Care Center
Hostel of
School &College
Rural Bank
Petrol Pump
Factory &Dairy
Equipment
Water Pump Lift In Society Railway Platform
AC Unit Cold Storage ATM Farm House
Microgrid
Government
Offices
Solar Farming
Centre
12. Enertech® Highly Reliable And Efficient Products are Backed by
A Highly Responsive and Dependable Field and Factory Services
Your business runs around the clock,and so does Enertech.With24x7 technicalsupport
coverage, including weekends and holidays,TheTechnicalSupport team at Enertech is
dedicated to protecting your investments
With factorytrainedengineers positioned throughout the India, rapid response times can
significantlyreducedowntimeand loss of revenue.
Highly skilledTechnicalSupport representativesare availableto troubleshoot by phone
and,If necessary, Can dispatch the expertServiceengineer to your site.
SERVICES
Start-up /Installation
Factory and On-siteT
esting
Preventive Maintenance
ExtendedWarranty
50+ Service
Personnel Pan-India
Pan-India
Spare Parts Operations
Wide Repair
Network
Pleasecall for
T
echnical Support
+91 9372623418
OurOffering
Online UPS, Static Frequency Converter,
Solar UPS, Industrial Battery Charger
Domestic and International Presence
7 x24 x365 Customer ServiceSuppor
Contact
Mob.: +91 9370659050, +91 9372623423
Web.:www.enertechups.com
Mail :sales@enertechups.com
ENERTECHUPS PVT
.L
TD.
S. No.399/1-2, Bhare,P
.0.Ghotawade,
Near Pirangut,T
aluka- Mulshi
Dist.-Pune - 412115
Follow Us On
EUPL/2021-22/Online UPS/01