SlideShare a Scribd company logo
We have a simple manifesto...
To maintain a high quality and sustainable
service to both commercial and residential
underfloor heating customers.
Base UFH Ltd is an industry leading company providing you with an individually tailored
under floor heating solution to meet your exact project requirements.
From detailed information acquired from our initial site survey, project drawings and an in
depth assessment of your requirements, BaseTM
offer you a complete underfloor heating
system design and supply service.
Using our extensive expertise within the industry, we strive to offer you an unrivalled level of
customer service and technical support throughout every stage of your project to ensure a
successful installation every time.
Our cost effective, energy efficient products can be quickly and easily installed into any type
of building, and can integrate seamlessly to work alongside renewable energy sources.
Whether a new build, refurbishment or commercial project, BaseTM
offers you proven
underfloor heating systems to give you the results you need.
AN INTRODUCTION TO BASE UFHCONTENTS
INTRODUCTION 05
DESIGN 06
CLIPRAIL SYSTEM 08
TACKER SYSTEM 10
MESH SYSTEM 12
PLATED SYSTEM 14
JOISTED PLATED EPS SYSTEM 1 16
JOISTED PLATED EPS SYSTEM 2 18
BISCUIT SCREED SYSTEM 20
STRUCTURAL IN-FLOORBOARD SYSTEM 22
FLOATING PLATED EPS SYSTEM 24
BATTEN PLATED EPS SYSTEM 26
ULTRA-LOW EPS SYSTEM 28
ULTRA-LOW PANEL SYSTEM 30
MANIFOLDS AND CONTROLS 32
Based on the information provided for your particular project and the
buildings characteristics, BaseTM
provide a complete bespoke underfloor
heating CAD design. Our comprehensive design provides the necessary
information and guidance to implement the correct system installation as
well as ensuring the performance requirements are achieved.
DESIGN
6
SYSTEM
» BaseTM
CLIPRAIL SYSTEM specifically designed for
use within a screeded floor construction
» Installs directly to suitable rigid insulation panel to
meet required thermal performance
» Offers design flexibility to accommodate irregular
design layouts
» 50mm cliprail spacing allows flexible pipe layout to
suit exact design requirements
» Additional pipe staples ensures secure pipe fixing
during screeding process
» Cost effective system offering excellent overall
performance
SYSTEM INSTALL
1. Rigid insulation required to subfloor in accordance
with required thermal performance and current
building regulations
2. Perimeter expansion edging strip to be installed
to perimeter with polymer staples ensuring
polyethylene skirting is covering sub floor rigid
insulation to prevent expansion of screed and
thermal bridging
3. Cliprail to be installed directly to rigid sub floor
insulation at 1000mm spacing fixed with polymer
pipe staples
4. 16mm PEX pipe to be installed directly to cliprail
in continuous lengths from distribution manifold
spaced according to underfloor heating design
5. Polymer staples to be fixed to pipe at 300mm spacing
6. Pipework to be pressure tested and remain under
pressure.
7. 65-75mm sand and cement screed / 50mm liquid
screed to be installed (by others)
CLIPRAIL SYSTEM
SPECIFICATION
BaseTM
CLIPRAIL SYSTEM to install directly to rigid
insulation using polymer clip rails and clips. 16mm PEX
pipework to install to clip rails pre spaced in accordance
with pipe layout design. Min 65mm sand and cement
/50mm liquid screed to be installed (by others)
Finished floor
Screed
PEX pipe
Cliprail
PIR foil faced
insulation
Subfloor
01
8
SYSTEM
» BaseTM
TACKER SYSTEM specifically designed for use
within a screeded floor construction
» Installs directly to a laminated gridded insulation
panel to suit specified thermal performance
» Offers design flexibility to accommodate irregular
design layouts
» Gridded spacing allows flexible pipe layout to suit
exact design requirements
» Pipe staples ensures secure pipe fixing during
screeding process.
» Cost effective system offering excellent overall
performance
SYSTEM INSTALL
1. Laminated gridded insulation panel to be installed
to subfloor. Panel depth in accordance with
required thermal performance and current building
regulations
2. Perimeter expansion edging strip to be installed
to perimeter with polymer staples ensuring
polyethylene skirting is covering sub floor rigid
insulation to prevent expansion of screed and
thermal bridging
3. PEX pipe to be installed directly to rigid sub floor
insulation at 300mm spacing fixed with polymer pipe
staples
4. 16mm PEX pipe to be installed directly to laminated
gridded insulation panel in continuous lengths from
distribution manifold spaced according to underfloor
heating design
5. 65-75mm sand and cement screed to be installed to
manufacturers specification
6. Pipework to be pressure tested and remain under
pressure
TACKER SYSTEM
SPECIFICATION
BaseTM
TACKER SYSTEM to incorporate
16mm PEX pipe to be installed to
laminated gridded insulation panel using
polymer pipe staples. Staples fixed at
300mm apart. Installation in accordance
with pipe layout design. Perimeter
expansion edging strip to be installed to
perimeter to prevent expansion of screed
and thermal bridging.
Finished floor
PEX Pipe
Screed
Staple
Laminated gridded
insulation
02
10
SYSTEM
» BaseTM
MESH SYSTEM specifically designed for use
within a screeded floor construction
» Re-enforced steel mesh grid to installed on top
of suitable foil faced rigid insulation panel in
accordance with required thermal performance
(Steel mesh by others)
» Installs directly to re-enforced steel mesh grid to suit
specified thermal performance
» Offers design flexibility to accommodate irregular
design layouts
» Cable ties allow flexible pipe layout to suit exact
design requirements
» Additional cable tie fixings ensure secure pipe fixing
during screeding process
» Cost effective system offering excellent overall
performance
SYSTEM INSTALL
1. Rigid insulation required to subfloor in accordance
with required thermal performance and current
building regulations
2. 8mm perimeter expansion edging strip to be
installed to perimeter with 40mm polymer staples
ensuring polyethylene skirting is covering sub floor
rigid insulation to prevent expansion of screed and
thermal bridging
3. PEX pipework to be installed directly to re-enforced
steel mesh grid with cable ties in accordance with
underfloor heating design
4. PEX pipe to be installed directly to re-enforced steel
mesh grid in continuous lengths from distribution
manifold spaced according to underfloor heating
design
5. Attach additional cable ties to PEX pipework as
required to ensure pipework is firmly attached to
steel re-enforced grid mesh so pipework remains in
place in accordance with underfloor heating design
6. Pipework to be pressure tested and remain under
pressure
7. 65-75mm sand and cement screed to be installed to
manufacturers specification
MESH SYSTEM
SPECIFICATION
BaseTM
MESH SYSTEM to install directly to
reinforced steel mesh using cable tie. 16mm
PEX pipework to be spaced in accordance with
pipe layout design. Min 65mm sand and cement
/50mm liquid screed to be installed (by others)
Tiled floor
Tile adhesive
Ditra mat
PEX Pipe
Screed
Reinforced mesh
Insulation
03
12
SYSTEM
» BaseTM
PLATED SYSTEM specifically designed for use
within a joisted floor construction
» Installs directly between joists finishing flush with
top of joist
» Aluminium heat diffusion plate onlyadding an
additional 0.5mm to floor build up
» Pipework is tightly encased within aluminium heat
diffusion plate ensuring even heat distribution across
the floor area
» Aluminium heat diffusion plates offer high heat
conductivity and quick system response
» Aluminium heat diffusion plate 1000mm x 390mm
x 0.6mm 10/50 commercial grade aluminium to
incorporate 16mm PEX pipe
SYSTEM INSTALL
1. Compressible Rockwool type insulation (minimum
200mm) required between joists pushed tightly to
the underside of the aluminium heat diffusion plate.
Insulation in accordance with required thermal
performance and current building regulations
2. Aluminium heat diffusion plateto be fixed flush with
top of joist
3. 16mm PEX pipe to be installed directly into heat
diffusion plate channels in continuous lengths from
distribution manifold spaced according to underfloor
heating design
4. Joists to be notchedin accordance with building
regulations. Pipe to be fixed to joists using nail clips
5. Pipework to be pressure tested and remain under
pressure
PLATED SYSTEM
SPECIFICATION
BaseTM
PLATED SYSTEM to
incorporate 16mm PEX pipe. Pipe
to be installed to aluminium plate
between joists in accordance with
pipe layout design.
Engineered timber board
Aluminium diffusion plate
PEX pipe
Quilted insulation
Joist
04
14
SYSTEM
» BaseTM
JOISTED PLATED EPS SYSTEM 1 specifically
designed for use within a joisted floor construction
» Installs directly between joists finishing flush with
top of joist
» Aluminium heat diffusion plate compressed into a
rigid EPS insulation panel only adding an additional
0.5mm to floor build up
» Pipework is tightly encased within aluminium heat
diffusion plate ensuring even heat distribution across
the floor area
» Aluminium heat diffusion plates offer high heat
conductivity and quick system response
» Aluminium heat diffusion plate 1000mm x 390mm x
0.5mm to incorporate 16mm PEX pipe
SYSTEM INSTALL
1. Rigid grooved EPS insulation installed tightly
between joists to receive aluminium diffusion plate
supported by framework. Insulation panel and
plate to finish flush to the top of the joist. Additional
Insulation in accordance with required thermal
performance and required building regulations
2. 16mm PEX pipe to be installed directly into heat
diffusion plate channels in continuous lengths from
distribution manifold spaced according to underfloor
heating design
3. Joists to be notched in accordance with building
regulation. Pipe to be fixed to joists using nail clips
4. Pipework to be pressure tested and remain under
pressure
JOISTED PLATED EPS SYSTEM 1
SPECIFICATION
BaseTM
JOISTED PLATED EPS
SYSTEM 1 to incorporate 16mm
PEX pipe. Pipe to be installed
to aluminium plate within pre-
grooved rigid EPS insulation
panel. Installation between
joists in accordance with pipe
layout design.
Finished floor
Aluminium diffusion plate
PEX pipe
Grooved EPS insulation
Joist
Support framework
05
16
SYSTEM
» BaseTM
50mm JOISTED PLATED EPS SYSTEM 2
specifically designed for use within a joisted floor
construction
» Installs directly between joists on to supporting
battens finishing flush with top of joist
» Aluminium heat diffusion plate tightly compressed
into a 50mm rigid EPS insulation panel
» Aluminium diffusion plate only adding additional
0.5mm to overall floor build up
» Pipework is tightly encased within aluminium heat
diffusion plate ensuring even heat distribution across
the floor area
» Aluminium heat diffusion plates offer high heat
conductivity and rapid system response
» Aluminium heat diffusion plate 1000mm x 390mm
x 0.5mm to incorporate 16mm x 2mm PEX oxygen
barrier pipe
SYSTEM INSTALL
1. 50mm rigid EPS insulation panel installed tightly
between joists to receive aluminium heat diffusion
plate. 50mm rigid EPS insulation panel to be
installed to supporting battens (by others)
2. Aluminium heat diffusion plate to be inserted into
50mm pre-grooved EPS panel to finish flush with top
of joist
3. 16mmPEX oxygen barrier pipe to be installed directly
in tochannel of heat diffusion plate in continuous
lengths from distribution manifold in accordance
with underfloor heating design
4. Joists to be notched in accordance with design and
building specification. Pipe to be fixed to notched
joist using nail clips
5. Pipework to be pressure tested and remain under
pressure
JOISTED PLATED EPS SYSTEM 2
SPECIFICATION
BaseTM
JOISTED PLATED EPS SYSTEM
2 to incorporate 16mm PEX pipe.
Pipe to be installed to aluminium
plate within 50MM pre-grooved rigid
EPS insulation panel. Installation
between joists in accordance with
pipe layout design.
Finished floor
Alumium diffusion plate
PEX pipe
50mm pre-grooved EPS
insulation
Support framework
Joist
06
18
SYSTEM
» BaseTM
BISCUIT SCREED SYSTEM specifically
designed for use within a joisted floor construction
» Installs directly between joists with screed layer
finishing flush with top of joist
» Pipe work is fixed directly to rigid type insulation with
pipe clips allowing design flexibility
» Pipe work is encased within 25-30mm sand and
cement biscuit screed layer ensuring even heat
distribution across the floor area
» Biscuit screed layer offers high heat conductivity and
heat retention
» Cost effective system with reduced installation time
SYSTEM INSTALL
1. Supporting timber battens to be fixed to inside of
joist to support engineered timber board sheet and
rigid insulation panel (by others)
2. Rigid insulation panels to be fitted directly upon
supporting engineered timber board between joists
to finish 25-30mm below top of joist (by others)
3. 16mm PEX pipe work to be fixed securely using pipe
clips directly to top side of rigid insulation panel
4. 16mm PEX pipe to be installed in continuous lengths
from distribution manifold spaced according to
underfloor heating design
5. Joists to be notched in accordance with building
regulations. Pipe to be fixed to joists using nail clips
6. Pipe work to be pressure tested and remain under
pressure
7. Installation of dry mix screed to finish flush with top
of joist (by others)
BISCUIT SCREED SYSTEM
SPECIFICATION
BaseTM
BISCUIT SCREED SYSTEM
to incorporate 16mm PEX pipe to be
installed to rigid Insulation panel using
polymer pipe staples. Rigid insulation
panel to finish 25-30mm below top
of joist to be supported by timber
framework. 25-30mm dry mix screed to
finish with top of joist.
Engineered timber board
Screed
PEX pipe
PIR foil faced insulation
Joist
Support framework
07
20
SYSTEM
» BaseTM
STRUCTURAL IN-FLOORBOARD SYSTEM
incorporating 16mm PEX pipework specifically
designed to fit directly on to joist as a structural floor
to be laid over 400mm centre joists
» Pre-grooved flooring panels offer an alternative
solution to traditional flooring systemsincorporating
the underfloor heating pipework and structural floor
in one panel
» Panel offering a low system build up from only 22mm
plus a 6mm engineered timber board to cover
» 16mm pipework is tightly encased within pre-grooved
channels with additional aluminium heat diffusion
tape covering pipework ensuring additional system
output and even heat distribution across floor
» BaseTM
flooring panel 1200mm x 600mm x 22mm
flooring grade tongue & groove panel
SYSTEM INSTALL
1. Tongue and groove flooringpanel installed directly
on to floor joists according to system design
layout. Panels to be screwed and glued directly
to floor joists with tongue and grooves fully glued
(Additional insulation specification in accordance with
required thermal performance and current building
regulations to be installed below flooring panel by
other)
2. 16mm pipework to be installed in to pre-grooved
routed channels with additional aluminium heat
diffusion tape installed over pipework with 6mm
engineered timber boardto be installed over 22mm
panel
3. 16mm pipework to be installed directly into pre-
grooved channels in continuous lengths from
distribution manifold spaced according to underfloor
heating design with pipework to drop between joist
space if required for suitable flow and return route to
manifold location
4. BaseTM
flooring panel to be additionally routed as
required to allow pipe installation route in accordance
with pipe layout design
5. Pipework to be pressure tested and remain under
pressure
STRUCTURAL IN-FLOORBOARD SYSTEM
SPECIFICATION
BaseTM
STRUCTURAL IN-BOARD
SYSTEM. PEX pipe installed to pre-
routed 2400mm x 600mm x 22mm
tongue & groove panel. Panel glued
and screwed to 400mm centre
joists. 6mm engineered timber
panel installed to tongue & groove
panel.
Finished floor
6mm engineered timber board
Foil faced tape
PEX pipe
Tongue & groove panel
Joist
Insulation
08
22
SYSTEM
» BaseTM
FLOATING EPS SYSTEM specifically designed
to fit directly on to sub-floor construction
» Pre-grooved EPS insulation panels offer quick
installation with ability to be cut to exact size required
in accordance with design
» Aluminium heat diffusion plate fits directly into pre-
grooved EPS panel offering a low system build up
from only 25mm
» Pipework is tightly encased within aluminium heat
diffusion plate ensuring even heat distribution across
the floor area with EPS panel to counter downward
heat loss
» Aluminium heat diffusion plates offer high heat
conductivity and quick system response
» Aluminium heat diffusion plate 1000mm x 390mm
x 0.5mm 10/50 commercial grade aluminium to
incorporate 16mm PEX pipe
SYSTEM INSTALL
1. EPS insulation panel installed directly on to subfloor
according to system design. (Insulation specification
in accordance with required thermal performance
and current building regulations. Rigid EPS panel
available from 25mm depth)
2. Aluminium heat diffusion plate to be fixed directly into
pre-grooved EPS insulation panel
3. 16mm PEX pipe to be installed directly into heat
diffusion plate channels in continuous lengths from
distribution manifold spaced according to underfloor
heating design
4. EPS insulation panel to be routed as required allowing
pipe installation in accordance with design layout
5. Pipework to be pressure tested and remain under
pressure
FLOATING PLATED EPS SYSTEM
SPECIFICATION
BaseTM
FLOATING PLATED EPS SYSTEM to
incorporate 16mm PEX pipe to be installed to
pre-grooved rigid EPS insulation panel. 0.5mm
aluminium heat diffusion plate to be fixed directly
into pre-grooved rigid EPS insulation panel.
Installation and design in accordance with pipe
layout design.
Finished floor
Engineered timber board
Aluminium diffusion plate
PEX pipe
Grooved EPS insulation
Sub floor
09
24
SYSTEM
» BaseTM
BATTEN PLATED EPS SYSTEM specifically
designed to fit directly to sub-floor construction
» 1200mm x 350mm x 25mm pre-grooved EPS
insulation installs directly between fixed battens
spaced equally to sub floor
» Aluminium heat diffusion plate fits directly into pre-
grooved EPS panel offering a low system build up of
only 30.5mm
» Pipework is tightly encased within aluminium heat
diffusion plate ensuring even heat distribution across
the floor area with EPS panel to counter downward
heat loss
» Aluminium heat diffusion plates offer high heat
conductivity and quick system response
» Aluminium heat diffusion plate 1000mm x 390mm x
0.5mm to incorporate 16mm PEX pipe
SYSTEM INSTALL
1. EPS insulation panel installed directly on to
subfloor between battens according to system
design. (Insulation specification in accordance with
required thermal performance and current building
regulations. Rigid EPS panel available from
25mm depth)
2. Aluminium heat diffusion plate to be fixed directly into
pre-grooved EPS insulation panel.
3. 16mm PEX pipe to be installed directly into heat
diffusion plate channels in continuous lengths from
distribution manifold spaced according to underfloor
heating design
4. EPS insulation panel to be routed as required
allowing pipe installation in accordance with design
layout.
5. Pipework to be pressure tested and remain
under pressure
BATTEN PLATED EPS SYSTEM
SPECIFICATION
BaseTM
BATTEN PLATED SYSTEM to
incorporate 16mm PEX pipe. Pipe to
be installed to aluminium diffusion
plate and pre-grooved rigid EPS
insulation panel. Battens to be fixed
to sub floor in accordance with pipe
layout design.
Engineered timber board
Aluminium diffusion plate
PEX pipe
Grooved EPS insulation
Batten
Sub floor
10
26
SYSTEM
» BaseTM
ULTRA-LOW EPS SYSTEM specifically
designed to fit directly on to sub-floor construction
» Pre-grooved foil faced EPS insulation panels offer
quick installation with ability to be cut to exact size
required in accordance with design
» Pre-grooved foil faced EPS panel offering a low
system build up of either 13mm or 17mm
» Pipework is tightly encased within pre-grooved foil
faced EPS panels ensuring even heat distribution
across the floor area. Foil faced panel to counter
downward heat loss
» Pre-grooved foil faced EPS panels offer high heat
conductivity and quick system response
SYSTEM INSTALL
1. Pre-grooved foil faced EPS panel installed directly
on to subfloor according to system design (additional
insulation may be required to meet required thermal
performance and current building regulations)
2. PEX pipe to be installed directly into pre-grooved foil
faced EPS panel
3. PEX pipe to be installed in continuous lengths from
distribution manifold spaced according to underfloor
heating design
4. Pre-grooved foil faced EPS panel to be routed as
required allowing pipe installation in accordance with
design layout
5. Pipe work to be pressure tested and remain under
pressure
ULTRA-LOW EPS SYSTEM
SPECIFICATION
BaseTM
ULTRA-LOW EPS SYSTEM to
incorporate 12mm or 16mm PEX pipe to
be installed to pre-grooved foil faced EPS
insulation panel. PEX pipework to be installed
directly into pre-grooved foil faced EPS
insulation panel (primer and self leveling
compound to be applied prior to tiled finish).
Installation and design in accordance with
pipelayout design.
Finished floor
17mm pre-grooved foil
faced EPS insulation
16mm PEX pipe
Subfloor
Finished floor
13mm pre-grooved foil
faced EPS insulation
12mm PEX pipe
Subfloor
11
28
ULTRA-LOW PANEL SYSTEM
Finished floor
Screed
PEX pipe
Screed board
Subfloor
SYSTEM
» BaseTM
ULTRA-LOW PANEL specifically designed to fit
directly on to sub-floor construction
» Pre-routed panels offer quick installation with ability
to be cut to exact size required in accordance with
design
» PEX pipe fits directly into pre-routed panel offering a
low system build up from only 15mm
» Pipework is tightly encased within pre-routed panel
ensuring even heat distribution across the floor area.
» Panels offer quick system response
SYSTEM INSTALL
1. Pre-routed panels installed directly on to subfloor
according to system design (additional insulation
to be installed below panel in accordance with
required thermal performance and current building
regulations)
2. PEX pipe to be installed directly into pre-routed
panels in continuous lengths from distribution
manifold, spaced according to underfloor heating
design
3. Additional blank panels to be routed as required
allowing pipe installation in accordance with design
layout
4. Pipework to be pressure tested and remain under
pressure
SPECIFICATION
BaseTM
ULTRA-LOW PANEL SYSTEM to incorporate PEX
pipe to be installed to pre-routed panels. Finished floor
to be layed directly to panel. Additional screed option for
tiled finish. Installation and design in accordance with pipe
layout design.
12
30
BaseTM
PEX PIPE
BaseTM
PEX is a high performance
pipe that is both flexible and extremely
resilient. Constructed from a superior
cross linked polyethylene, our pipe
benefits from a much higher resistance
to both heat and pressure compared to
other forms of PEX pipe, resulting in
much greater strength and durability.
» 100% impermeable oxygen
diffusion barrier
» Operational temperature up to 90 ºC
» Extremely flexible pipe for ease of
installation
» Maintenance free
» Meets EN ISO 15875 standard
SYSTEM CONTROLS
Our comprehensive range of innovative
system controls offer the ultimate in both
stylish, discreet design, coupled with
intuitive, user friendly operation.
Our slimline series of thermostats offer
an extensive range of control options,
to include touch-screen, wireless, wifi,
networked and via mobile app (Apple and
Android platforms)
MANIFOLDS
Our precision engineered BaseTM
Nickel
plated manifold offers complete system
control through the utilisation of adjustable
flow gauges, mixing valve and ‘A’ rated
pump. The distribution of low temperature
warm water is precisely regulated to each
individual zone of the underfloor heating
system.
MANIFOLDS AND CONTROLS
32
NOTES/DRAWINGS:

More Related Content

What's hot

Design Portfolio by Aaron Kaira
Design Portfolio by Aaron KairaDesign Portfolio by Aaron Kaira
Design Portfolio by Aaron KairaAaron Kaira
 
Polyform Presentation
Polyform PresentationPolyform Presentation
Polyform Presentation
polyformbinder
 
Fm 00064 ams composite standing seam ii panel june, 2009_129236159432863269
Fm 00064 ams composite standing seam ii panel  june, 2009_129236159432863269Fm 00064 ams composite standing seam ii panel  june, 2009_129236159432863269
Fm 00064 ams composite standing seam ii panel june, 2009_129236159432863269Shaik Abdulla
 
School Buildings of the Future
School Buildings of the FutureSchool Buildings of the Future
School Buildings of the FutureEdel Fox
 
Polyform's new products in provisional patent
Polyform's new products in provisional patentPolyform's new products in provisional patent
Polyform's new products in provisional patent
polyformbinder
 
Mill 14-1-15 - Sheet - A118 - 3D SECTIONS
Mill 14-1-15 - Sheet - A118 - 3D SECTIONSMill 14-1-15 - Sheet - A118 - 3D SECTIONS
Mill 14-1-15 - Sheet - A118 - 3D SECTIONSSin Byrne
 
Leisure Centre
Leisure CentreLeisure Centre
Leisure CentreEdel Fox
 
Restoration, extension and upgradation of protected structures
Restoration, extension and upgradation of protected structuresRestoration, extension and upgradation of protected structures
Restoration, extension and upgradation of protected structuresEdel Fox
 
Versaloc
VersalocVersaloc
Versaloc
kristenjames
 
CURTAIN WALL
CURTAIN WALLCURTAIN WALL
CURTAIN WALL
Chandarani Saste
 
11-Working details-cladding-cat alpolic guide-by Prof Dr. Ehab Ezzat 2019
11-Working details-cladding-cat alpolic  guide-by Prof Dr. Ehab Ezzat 201911-Working details-cladding-cat alpolic  guide-by Prof Dr. Ehab Ezzat 2019
11-Working details-cladding-cat alpolic guide-by Prof Dr. Ehab Ezzat 2019
Faculty of fine arts -Cairo. Egypt.
 
06-Working details-cladding-Marble-by Prof Dr. Ehab Ezzat 2018
06-Working details-cladding-Marble-by Prof Dr. Ehab Ezzat 201806-Working details-cladding-Marble-by Prof Dr. Ehab Ezzat 2018
06-Working details-cladding-Marble-by Prof Dr. Ehab Ezzat 2018
Faculty of fine arts -Cairo. Egypt.
 
15-Working details-cladding-External Timber cladding guide-by Prof Dr. Ehab E...
15-Working details-cladding-External Timber cladding guide-by Prof Dr. Ehab E...15-Working details-cladding-External Timber cladding guide-by Prof Dr. Ehab E...
15-Working details-cladding-External Timber cladding guide-by Prof Dr. Ehab E...
Faculty of fine arts -Cairo. Egypt.
 
Visual Dictionary 2- Conrete
Visual Dictionary 2- ConreteVisual Dictionary 2- Conrete
Visual Dictionary 2- Conreteconcrete
 
Curtain walls
Curtain wallsCurtain walls
Curtain walls
Aaqib Iqbal
 
curtain wall -skin of building
 curtain wall -skin of building curtain wall -skin of building
curtain wall -skin of building
abidha karthu
 
04-Working details-cladding-Glass curtain walls guide-by Prof Dr. Ehab Ezzat ...
04-Working details-cladding-Glass curtain walls guide-by Prof Dr. Ehab Ezzat ...04-Working details-cladding-Glass curtain walls guide-by Prof Dr. Ehab Ezzat ...
04-Working details-cladding-Glass curtain walls guide-by Prof Dr. Ehab Ezzat ...
Faculty of fine arts -Cairo. Egypt.
 
Facade engineering
Facade engineeringFacade engineering
Facade engineering
Kunaraj Sujeevan
 
Curtain glazing presentation
Curtain glazing presentationCurtain glazing presentation
Curtain glazing presentation
AwanishKeshri
 

What's hot (20)

Design Portfolio by Aaron Kaira
Design Portfolio by Aaron KairaDesign Portfolio by Aaron Kaira
Design Portfolio by Aaron Kaira
 
Polyform Presentation
Polyform PresentationPolyform Presentation
Polyform Presentation
 
Fm 00064 ams composite standing seam ii panel june, 2009_129236159432863269
Fm 00064 ams composite standing seam ii panel  june, 2009_129236159432863269Fm 00064 ams composite standing seam ii panel  june, 2009_129236159432863269
Fm 00064 ams composite standing seam ii panel june, 2009_129236159432863269
 
CONFORTO
CONFORTOCONFORTO
CONFORTO
 
School Buildings of the Future
School Buildings of the FutureSchool Buildings of the Future
School Buildings of the Future
 
Polyform's new products in provisional patent
Polyform's new products in provisional patentPolyform's new products in provisional patent
Polyform's new products in provisional patent
 
Mill 14-1-15 - Sheet - A118 - 3D SECTIONS
Mill 14-1-15 - Sheet - A118 - 3D SECTIONSMill 14-1-15 - Sheet - A118 - 3D SECTIONS
Mill 14-1-15 - Sheet - A118 - 3D SECTIONS
 
Leisure Centre
Leisure CentreLeisure Centre
Leisure Centre
 
Restoration, extension and upgradation of protected structures
Restoration, extension and upgradation of protected structuresRestoration, extension and upgradation of protected structures
Restoration, extension and upgradation of protected structures
 
Versaloc
VersalocVersaloc
Versaloc
 
CURTAIN WALL
CURTAIN WALLCURTAIN WALL
CURTAIN WALL
 
11-Working details-cladding-cat alpolic guide-by Prof Dr. Ehab Ezzat 2019
11-Working details-cladding-cat alpolic  guide-by Prof Dr. Ehab Ezzat 201911-Working details-cladding-cat alpolic  guide-by Prof Dr. Ehab Ezzat 2019
11-Working details-cladding-cat alpolic guide-by Prof Dr. Ehab Ezzat 2019
 
06-Working details-cladding-Marble-by Prof Dr. Ehab Ezzat 2018
06-Working details-cladding-Marble-by Prof Dr. Ehab Ezzat 201806-Working details-cladding-Marble-by Prof Dr. Ehab Ezzat 2018
06-Working details-cladding-Marble-by Prof Dr. Ehab Ezzat 2018
 
15-Working details-cladding-External Timber cladding guide-by Prof Dr. Ehab E...
15-Working details-cladding-External Timber cladding guide-by Prof Dr. Ehab E...15-Working details-cladding-External Timber cladding guide-by Prof Dr. Ehab E...
15-Working details-cladding-External Timber cladding guide-by Prof Dr. Ehab E...
 
Visual Dictionary 2- Conrete
Visual Dictionary 2- ConreteVisual Dictionary 2- Conrete
Visual Dictionary 2- Conrete
 
Curtain walls
Curtain wallsCurtain walls
Curtain walls
 
curtain wall -skin of building
 curtain wall -skin of building curtain wall -skin of building
curtain wall -skin of building
 
04-Working details-cladding-Glass curtain walls guide-by Prof Dr. Ehab Ezzat ...
04-Working details-cladding-Glass curtain walls guide-by Prof Dr. Ehab Ezzat ...04-Working details-cladding-Glass curtain walls guide-by Prof Dr. Ehab Ezzat ...
04-Working details-cladding-Glass curtain walls guide-by Prof Dr. Ehab Ezzat ...
 
Facade engineering
Facade engineeringFacade engineering
Facade engineering
 
Curtain glazing presentation
Curtain glazing presentationCurtain glazing presentation
Curtain glazing presentation
 

Viewers also liked

Iisrt saravana kumar
Iisrt saravana kumarIisrt saravana kumar
Iisrt saravana kumar
IISRT
 
Demeass Iv D Alessandro
Demeass Iv   D AlessandroDemeass Iv   D Alessandro
Demeass Iv D Alessandro
vincidale
 
Tech_Brochure_Cladding_Remake_Booklet_LQ_Email
Tech_Brochure_Cladding_Remake_Booklet_LQ_EmailTech_Brochure_Cladding_Remake_Booklet_LQ_Email
Tech_Brochure_Cladding_Remake_Booklet_LQ_EmailMiddle East Insulation LLC
 
Honeycomb Carbon Materials
Honeycomb  Carbon MaterialsHoneycomb  Carbon Materials
Honeycomb Carbon Materials
Gaurav Singh Chandel
 
Sandwichpanel pptSandwich Puf Panels Manufacturers
Sandwichpanel pptSandwich Puf Panels ManufacturersSandwichpanel pptSandwich Puf Panels Manufacturers
Sandwichpanel pptSandwich Puf Panels Manufacturers
sandwichpanels
 
Acp
AcpAcp
Aluminium composite panel
Aluminium composite panelAluminium composite panel
Aluminium composite panel
ARZEUS Architects
 
5M presentation 2015
5M presentation 20155M presentation 2015
5M presentation 2015Martin Janca
 
Sound insulation materials
Sound insulation materials Sound insulation materials
Sound insulation materials shalomsunny
 
Heat & sound insulation
Heat & sound insulationHeat & sound insulation
Heat & sound insulation
Manish Jain Luhadia
 

Viewers also liked (11)

Iisrt saravana kumar
Iisrt saravana kumarIisrt saravana kumar
Iisrt saravana kumar
 
Demeass Iv D Alessandro
Demeass Iv   D AlessandroDemeass Iv   D Alessandro
Demeass Iv D Alessandro
 
Tech_Brochure_Cladding_Remake_Booklet_LQ_Email
Tech_Brochure_Cladding_Remake_Booklet_LQ_EmailTech_Brochure_Cladding_Remake_Booklet_LQ_Email
Tech_Brochure_Cladding_Remake_Booklet_LQ_Email
 
Honeycomb Carbon Materials
Honeycomb  Carbon MaterialsHoneycomb  Carbon Materials
Honeycomb Carbon Materials
 
Sandwichpanel pptSandwich Puf Panels Manufacturers
Sandwichpanel pptSandwich Puf Panels ManufacturersSandwichpanel pptSandwich Puf Panels Manufacturers
Sandwichpanel pptSandwich Puf Panels Manufacturers
 
Acp
AcpAcp
Acp
 
Aluminium composite panel
Aluminium composite panelAluminium composite panel
Aluminium composite panel
 
5M presentation 2015
5M presentation 20155M presentation 2015
5M presentation 2015
 
Sandwich panels
Sandwich panelsSandwich panels
Sandwich panels
 
Sound insulation materials
Sound insulation materials Sound insulation materials
Sound insulation materials
 
Heat & sound insulation
Heat & sound insulationHeat & sound insulation
Heat & sound insulation
 

Similar to Base UFH Brochure 2016

House Odendahl (SITE PLAN)-A1
House Odendahl (SITE PLAN)-A1House Odendahl (SITE PLAN)-A1
House Odendahl (SITE PLAN)-A1David Dinsdale
 
Hipacuk cryo support
Hipacuk cryo supportHipacuk cryo support
Hipacuk cryo support
pacu68
 
MRC Group - (LOW RES) Excellence Metal Roofing pages
MRC Group - (LOW RES) Excellence Metal Roofing pagesMRC Group - (LOW RES) Excellence Metal Roofing pages
MRC Group - (LOW RES) Excellence Metal Roofing pagesRichard Polling
 
Isokern Celsius stove system installation instructions
Isokern Celsius stove system installation instructionsIsokern Celsius stove system installation instructions
Isokern Celsius stove system installation instructions
Schiedel UK
 
Greenflex presentation 0117
Greenflex presentation 0117Greenflex presentation 0117
Greenflex presentation 0117
Giulio Zanelli
 
Jeremias prefab modular systems vs traditional exhaust piping
Jeremias prefab modular systems vs traditional exhaust pipingJeremias prefab modular systems vs traditional exhaust piping
Jeremias prefab modular systems vs traditional exhaust piping
Roberto Gutierrez
 
Xtratherm XtraFall Brochure (Web) IREBXFXXFA4
Xtratherm XtraFall Brochure (Web) IREBXFXXFA4Xtratherm XtraFall Brochure (Web) IREBXFXXFA4
Xtratherm XtraFall Brochure (Web) IREBXFXXFA4Sarah Vanden Broeck
 
Scs – A World Of Possibilities R New
Scs – A World Of Possibilities R NewScs – A World Of Possibilities R New
Scs – A World Of Possibilities R Newneerajtri
 
Acopladores para armaduras
Acopladores para armadurasAcopladores para armaduras
Acopladores para armaduras
CORTARTEC
 
Jack_Lambourne - Portfolio
Jack_Lambourne - PortfolioJack_Lambourne - Portfolio
Jack_Lambourne - PortfolioJack Lambourne
 
LiveIn Quarters
LiveIn QuartersLiveIn Quarters
LiveIn Quarters
clicknow
 
Euro Style Design Ltd Arxx P Panel Dura Viessmann Commercialresidential
Euro Style Design Ltd Arxx P Panel Dura Viessmann CommercialresidentialEuro Style Design Ltd Arxx P Panel Dura Viessmann Commercialresidential
Euro Style Design Ltd Arxx P Panel Dura Viessmann Commercialresidential
Roland Laufer
 
Freelance project management case studies - residential
Freelance project management case studies - residentialFreelance project management case studies - residential
Freelance project management case studies - residentialgrahamelanders
 
Isokern Brochure
Isokern BrochureIsokern Brochure
Isokern Brochure
Schiedel UK
 
Aasra Martech Pvt. Ltd., New Delhi, Prefab Building Systems
Aasra Martech Pvt. Ltd., New Delhi, Prefab Building SystemsAasra Martech Pvt. Ltd., New Delhi, Prefab Building Systems
Aasra Martech Pvt. Ltd., New Delhi, Prefab Building Systems
IndiaMART InterMESH Limited
 
Ceramic Brochure
Ceramic BrochureCeramic Brochure
Ceramic Brochure
Schiedel UK
 
EPS Core Panel System
EPS Core Panel SystemEPS Core Panel System
EPS Core Panel System
JnaneshPreethan
 
EJOT Flat Roofing Brochure
EJOT Flat Roofing BrochureEJOT Flat Roofing Brochure
EJOT Flat Roofing Brochure
Nathan Handley
 
BPA GmbH English 2014
BPA GmbH English 2014BPA GmbH English 2014
BPA GmbH English 2014
Adrian Pflieger
 

Similar to Base UFH Brochure 2016 (20)

TT_BlueBook
TT_BlueBookTT_BlueBook
TT_BlueBook
 
House Odendahl (SITE PLAN)-A1
House Odendahl (SITE PLAN)-A1House Odendahl (SITE PLAN)-A1
House Odendahl (SITE PLAN)-A1
 
Hipacuk cryo support
Hipacuk cryo supportHipacuk cryo support
Hipacuk cryo support
 
MRC Group - (LOW RES) Excellence Metal Roofing pages
MRC Group - (LOW RES) Excellence Metal Roofing pagesMRC Group - (LOW RES) Excellence Metal Roofing pages
MRC Group - (LOW RES) Excellence Metal Roofing pages
 
Isokern Celsius stove system installation instructions
Isokern Celsius stove system installation instructionsIsokern Celsius stove system installation instructions
Isokern Celsius stove system installation instructions
 
Greenflex presentation 0117
Greenflex presentation 0117Greenflex presentation 0117
Greenflex presentation 0117
 
Jeremias prefab modular systems vs traditional exhaust piping
Jeremias prefab modular systems vs traditional exhaust pipingJeremias prefab modular systems vs traditional exhaust piping
Jeremias prefab modular systems vs traditional exhaust piping
 
Xtratherm XtraFall Brochure (Web) IREBXFXXFA4
Xtratherm XtraFall Brochure (Web) IREBXFXXFA4Xtratherm XtraFall Brochure (Web) IREBXFXXFA4
Xtratherm XtraFall Brochure (Web) IREBXFXXFA4
 
Scs – A World Of Possibilities R New
Scs – A World Of Possibilities R NewScs – A World Of Possibilities R New
Scs – A World Of Possibilities R New
 
Acopladores para armaduras
Acopladores para armadurasAcopladores para armaduras
Acopladores para armaduras
 
Jack_Lambourne - Portfolio
Jack_Lambourne - PortfolioJack_Lambourne - Portfolio
Jack_Lambourne - Portfolio
 
LiveIn Quarters
LiveIn QuartersLiveIn Quarters
LiveIn Quarters
 
Euro Style Design Ltd Arxx P Panel Dura Viessmann Commercialresidential
Euro Style Design Ltd Arxx P Panel Dura Viessmann CommercialresidentialEuro Style Design Ltd Arxx P Panel Dura Viessmann Commercialresidential
Euro Style Design Ltd Arxx P Panel Dura Viessmann Commercialresidential
 
Freelance project management case studies - residential
Freelance project management case studies - residentialFreelance project management case studies - residential
Freelance project management case studies - residential
 
Isokern Brochure
Isokern BrochureIsokern Brochure
Isokern Brochure
 
Aasra Martech Pvt. Ltd., New Delhi, Prefab Building Systems
Aasra Martech Pvt. Ltd., New Delhi, Prefab Building SystemsAasra Martech Pvt. Ltd., New Delhi, Prefab Building Systems
Aasra Martech Pvt. Ltd., New Delhi, Prefab Building Systems
 
Ceramic Brochure
Ceramic BrochureCeramic Brochure
Ceramic Brochure
 
EPS Core Panel System
EPS Core Panel SystemEPS Core Panel System
EPS Core Panel System
 
EJOT Flat Roofing Brochure
EJOT Flat Roofing BrochureEJOT Flat Roofing Brochure
EJOT Flat Roofing Brochure
 
BPA GmbH English 2014
BPA GmbH English 2014BPA GmbH English 2014
BPA GmbH English 2014
 

Base UFH Brochure 2016

  • 1.
  • 2. We have a simple manifesto... To maintain a high quality and sustainable service to both commercial and residential underfloor heating customers.
  • 3. Base UFH Ltd is an industry leading company providing you with an individually tailored under floor heating solution to meet your exact project requirements. From detailed information acquired from our initial site survey, project drawings and an in depth assessment of your requirements, BaseTM offer you a complete underfloor heating system design and supply service. Using our extensive expertise within the industry, we strive to offer you an unrivalled level of customer service and technical support throughout every stage of your project to ensure a successful installation every time. Our cost effective, energy efficient products can be quickly and easily installed into any type of building, and can integrate seamlessly to work alongside renewable energy sources. Whether a new build, refurbishment or commercial project, BaseTM offers you proven underfloor heating systems to give you the results you need. AN INTRODUCTION TO BASE UFHCONTENTS INTRODUCTION 05 DESIGN 06 CLIPRAIL SYSTEM 08 TACKER SYSTEM 10 MESH SYSTEM 12 PLATED SYSTEM 14 JOISTED PLATED EPS SYSTEM 1 16 JOISTED PLATED EPS SYSTEM 2 18 BISCUIT SCREED SYSTEM 20 STRUCTURAL IN-FLOORBOARD SYSTEM 22 FLOATING PLATED EPS SYSTEM 24 BATTEN PLATED EPS SYSTEM 26 ULTRA-LOW EPS SYSTEM 28 ULTRA-LOW PANEL SYSTEM 30 MANIFOLDS AND CONTROLS 32
  • 4. Based on the information provided for your particular project and the buildings characteristics, BaseTM provide a complete bespoke underfloor heating CAD design. Our comprehensive design provides the necessary information and guidance to implement the correct system installation as well as ensuring the performance requirements are achieved. DESIGN 6
  • 5. SYSTEM » BaseTM CLIPRAIL SYSTEM specifically designed for use within a screeded floor construction » Installs directly to suitable rigid insulation panel to meet required thermal performance » Offers design flexibility to accommodate irregular design layouts » 50mm cliprail spacing allows flexible pipe layout to suit exact design requirements » Additional pipe staples ensures secure pipe fixing during screeding process » Cost effective system offering excellent overall performance SYSTEM INSTALL 1. Rigid insulation required to subfloor in accordance with required thermal performance and current building regulations 2. Perimeter expansion edging strip to be installed to perimeter with polymer staples ensuring polyethylene skirting is covering sub floor rigid insulation to prevent expansion of screed and thermal bridging 3. Cliprail to be installed directly to rigid sub floor insulation at 1000mm spacing fixed with polymer pipe staples 4. 16mm PEX pipe to be installed directly to cliprail in continuous lengths from distribution manifold spaced according to underfloor heating design 5. Polymer staples to be fixed to pipe at 300mm spacing 6. Pipework to be pressure tested and remain under pressure. 7. 65-75mm sand and cement screed / 50mm liquid screed to be installed (by others) CLIPRAIL SYSTEM SPECIFICATION BaseTM CLIPRAIL SYSTEM to install directly to rigid insulation using polymer clip rails and clips. 16mm PEX pipework to install to clip rails pre spaced in accordance with pipe layout design. Min 65mm sand and cement /50mm liquid screed to be installed (by others) Finished floor Screed PEX pipe Cliprail PIR foil faced insulation Subfloor 01 8
  • 6. SYSTEM » BaseTM TACKER SYSTEM specifically designed for use within a screeded floor construction » Installs directly to a laminated gridded insulation panel to suit specified thermal performance » Offers design flexibility to accommodate irregular design layouts » Gridded spacing allows flexible pipe layout to suit exact design requirements » Pipe staples ensures secure pipe fixing during screeding process. » Cost effective system offering excellent overall performance SYSTEM INSTALL 1. Laminated gridded insulation panel to be installed to subfloor. Panel depth in accordance with required thermal performance and current building regulations 2. Perimeter expansion edging strip to be installed to perimeter with polymer staples ensuring polyethylene skirting is covering sub floor rigid insulation to prevent expansion of screed and thermal bridging 3. PEX pipe to be installed directly to rigid sub floor insulation at 300mm spacing fixed with polymer pipe staples 4. 16mm PEX pipe to be installed directly to laminated gridded insulation panel in continuous lengths from distribution manifold spaced according to underfloor heating design 5. 65-75mm sand and cement screed to be installed to manufacturers specification 6. Pipework to be pressure tested and remain under pressure TACKER SYSTEM SPECIFICATION BaseTM TACKER SYSTEM to incorporate 16mm PEX pipe to be installed to laminated gridded insulation panel using polymer pipe staples. Staples fixed at 300mm apart. Installation in accordance with pipe layout design. Perimeter expansion edging strip to be installed to perimeter to prevent expansion of screed and thermal bridging. Finished floor PEX Pipe Screed Staple Laminated gridded insulation 02 10
  • 7. SYSTEM » BaseTM MESH SYSTEM specifically designed for use within a screeded floor construction » Re-enforced steel mesh grid to installed on top of suitable foil faced rigid insulation panel in accordance with required thermal performance (Steel mesh by others) » Installs directly to re-enforced steel mesh grid to suit specified thermal performance » Offers design flexibility to accommodate irregular design layouts » Cable ties allow flexible pipe layout to suit exact design requirements » Additional cable tie fixings ensure secure pipe fixing during screeding process » Cost effective system offering excellent overall performance SYSTEM INSTALL 1. Rigid insulation required to subfloor in accordance with required thermal performance and current building regulations 2. 8mm perimeter expansion edging strip to be installed to perimeter with 40mm polymer staples ensuring polyethylene skirting is covering sub floor rigid insulation to prevent expansion of screed and thermal bridging 3. PEX pipework to be installed directly to re-enforced steel mesh grid with cable ties in accordance with underfloor heating design 4. PEX pipe to be installed directly to re-enforced steel mesh grid in continuous lengths from distribution manifold spaced according to underfloor heating design 5. Attach additional cable ties to PEX pipework as required to ensure pipework is firmly attached to steel re-enforced grid mesh so pipework remains in place in accordance with underfloor heating design 6. Pipework to be pressure tested and remain under pressure 7. 65-75mm sand and cement screed to be installed to manufacturers specification MESH SYSTEM SPECIFICATION BaseTM MESH SYSTEM to install directly to reinforced steel mesh using cable tie. 16mm PEX pipework to be spaced in accordance with pipe layout design. Min 65mm sand and cement /50mm liquid screed to be installed (by others) Tiled floor Tile adhesive Ditra mat PEX Pipe Screed Reinforced mesh Insulation 03 12
  • 8. SYSTEM » BaseTM PLATED SYSTEM specifically designed for use within a joisted floor construction » Installs directly between joists finishing flush with top of joist » Aluminium heat diffusion plate onlyadding an additional 0.5mm to floor build up » Pipework is tightly encased within aluminium heat diffusion plate ensuring even heat distribution across the floor area » Aluminium heat diffusion plates offer high heat conductivity and quick system response » Aluminium heat diffusion plate 1000mm x 390mm x 0.6mm 10/50 commercial grade aluminium to incorporate 16mm PEX pipe SYSTEM INSTALL 1. Compressible Rockwool type insulation (minimum 200mm) required between joists pushed tightly to the underside of the aluminium heat diffusion plate. Insulation in accordance with required thermal performance and current building regulations 2. Aluminium heat diffusion plateto be fixed flush with top of joist 3. 16mm PEX pipe to be installed directly into heat diffusion plate channels in continuous lengths from distribution manifold spaced according to underfloor heating design 4. Joists to be notchedin accordance with building regulations. Pipe to be fixed to joists using nail clips 5. Pipework to be pressure tested and remain under pressure PLATED SYSTEM SPECIFICATION BaseTM PLATED SYSTEM to incorporate 16mm PEX pipe. Pipe to be installed to aluminium plate between joists in accordance with pipe layout design. Engineered timber board Aluminium diffusion plate PEX pipe Quilted insulation Joist 04 14
  • 9. SYSTEM » BaseTM JOISTED PLATED EPS SYSTEM 1 specifically designed for use within a joisted floor construction » Installs directly between joists finishing flush with top of joist » Aluminium heat diffusion plate compressed into a rigid EPS insulation panel only adding an additional 0.5mm to floor build up » Pipework is tightly encased within aluminium heat diffusion plate ensuring even heat distribution across the floor area » Aluminium heat diffusion plates offer high heat conductivity and quick system response » Aluminium heat diffusion plate 1000mm x 390mm x 0.5mm to incorporate 16mm PEX pipe SYSTEM INSTALL 1. Rigid grooved EPS insulation installed tightly between joists to receive aluminium diffusion plate supported by framework. Insulation panel and plate to finish flush to the top of the joist. Additional Insulation in accordance with required thermal performance and required building regulations 2. 16mm PEX pipe to be installed directly into heat diffusion plate channels in continuous lengths from distribution manifold spaced according to underfloor heating design 3. Joists to be notched in accordance with building regulation. Pipe to be fixed to joists using nail clips 4. Pipework to be pressure tested and remain under pressure JOISTED PLATED EPS SYSTEM 1 SPECIFICATION BaseTM JOISTED PLATED EPS SYSTEM 1 to incorporate 16mm PEX pipe. Pipe to be installed to aluminium plate within pre- grooved rigid EPS insulation panel. Installation between joists in accordance with pipe layout design. Finished floor Aluminium diffusion plate PEX pipe Grooved EPS insulation Joist Support framework 05 16
  • 10. SYSTEM » BaseTM 50mm JOISTED PLATED EPS SYSTEM 2 specifically designed for use within a joisted floor construction » Installs directly between joists on to supporting battens finishing flush with top of joist » Aluminium heat diffusion plate tightly compressed into a 50mm rigid EPS insulation panel » Aluminium diffusion plate only adding additional 0.5mm to overall floor build up » Pipework is tightly encased within aluminium heat diffusion plate ensuring even heat distribution across the floor area » Aluminium heat diffusion plates offer high heat conductivity and rapid system response » Aluminium heat diffusion plate 1000mm x 390mm x 0.5mm to incorporate 16mm x 2mm PEX oxygen barrier pipe SYSTEM INSTALL 1. 50mm rigid EPS insulation panel installed tightly between joists to receive aluminium heat diffusion plate. 50mm rigid EPS insulation panel to be installed to supporting battens (by others) 2. Aluminium heat diffusion plate to be inserted into 50mm pre-grooved EPS panel to finish flush with top of joist 3. 16mmPEX oxygen barrier pipe to be installed directly in tochannel of heat diffusion plate in continuous lengths from distribution manifold in accordance with underfloor heating design 4. Joists to be notched in accordance with design and building specification. Pipe to be fixed to notched joist using nail clips 5. Pipework to be pressure tested and remain under pressure JOISTED PLATED EPS SYSTEM 2 SPECIFICATION BaseTM JOISTED PLATED EPS SYSTEM 2 to incorporate 16mm PEX pipe. Pipe to be installed to aluminium plate within 50MM pre-grooved rigid EPS insulation panel. Installation between joists in accordance with pipe layout design. Finished floor Alumium diffusion plate PEX pipe 50mm pre-grooved EPS insulation Support framework Joist 06 18
  • 11. SYSTEM » BaseTM BISCUIT SCREED SYSTEM specifically designed for use within a joisted floor construction » Installs directly between joists with screed layer finishing flush with top of joist » Pipe work is fixed directly to rigid type insulation with pipe clips allowing design flexibility » Pipe work is encased within 25-30mm sand and cement biscuit screed layer ensuring even heat distribution across the floor area » Biscuit screed layer offers high heat conductivity and heat retention » Cost effective system with reduced installation time SYSTEM INSTALL 1. Supporting timber battens to be fixed to inside of joist to support engineered timber board sheet and rigid insulation panel (by others) 2. Rigid insulation panels to be fitted directly upon supporting engineered timber board between joists to finish 25-30mm below top of joist (by others) 3. 16mm PEX pipe work to be fixed securely using pipe clips directly to top side of rigid insulation panel 4. 16mm PEX pipe to be installed in continuous lengths from distribution manifold spaced according to underfloor heating design 5. Joists to be notched in accordance with building regulations. Pipe to be fixed to joists using nail clips 6. Pipe work to be pressure tested and remain under pressure 7. Installation of dry mix screed to finish flush with top of joist (by others) BISCUIT SCREED SYSTEM SPECIFICATION BaseTM BISCUIT SCREED SYSTEM to incorporate 16mm PEX pipe to be installed to rigid Insulation panel using polymer pipe staples. Rigid insulation panel to finish 25-30mm below top of joist to be supported by timber framework. 25-30mm dry mix screed to finish with top of joist. Engineered timber board Screed PEX pipe PIR foil faced insulation Joist Support framework 07 20
  • 12. SYSTEM » BaseTM STRUCTURAL IN-FLOORBOARD SYSTEM incorporating 16mm PEX pipework specifically designed to fit directly on to joist as a structural floor to be laid over 400mm centre joists » Pre-grooved flooring panels offer an alternative solution to traditional flooring systemsincorporating the underfloor heating pipework and structural floor in one panel » Panel offering a low system build up from only 22mm plus a 6mm engineered timber board to cover » 16mm pipework is tightly encased within pre-grooved channels with additional aluminium heat diffusion tape covering pipework ensuring additional system output and even heat distribution across floor » BaseTM flooring panel 1200mm x 600mm x 22mm flooring grade tongue & groove panel SYSTEM INSTALL 1. Tongue and groove flooringpanel installed directly on to floor joists according to system design layout. Panels to be screwed and glued directly to floor joists with tongue and grooves fully glued (Additional insulation specification in accordance with required thermal performance and current building regulations to be installed below flooring panel by other) 2. 16mm pipework to be installed in to pre-grooved routed channels with additional aluminium heat diffusion tape installed over pipework with 6mm engineered timber boardto be installed over 22mm panel 3. 16mm pipework to be installed directly into pre- grooved channels in continuous lengths from distribution manifold spaced according to underfloor heating design with pipework to drop between joist space if required for suitable flow and return route to manifold location 4. BaseTM flooring panel to be additionally routed as required to allow pipe installation route in accordance with pipe layout design 5. Pipework to be pressure tested and remain under pressure STRUCTURAL IN-FLOORBOARD SYSTEM SPECIFICATION BaseTM STRUCTURAL IN-BOARD SYSTEM. PEX pipe installed to pre- routed 2400mm x 600mm x 22mm tongue & groove panel. Panel glued and screwed to 400mm centre joists. 6mm engineered timber panel installed to tongue & groove panel. Finished floor 6mm engineered timber board Foil faced tape PEX pipe Tongue & groove panel Joist Insulation 08 22
  • 13. SYSTEM » BaseTM FLOATING EPS SYSTEM specifically designed to fit directly on to sub-floor construction » Pre-grooved EPS insulation panels offer quick installation with ability to be cut to exact size required in accordance with design » Aluminium heat diffusion plate fits directly into pre- grooved EPS panel offering a low system build up from only 25mm » Pipework is tightly encased within aluminium heat diffusion plate ensuring even heat distribution across the floor area with EPS panel to counter downward heat loss » Aluminium heat diffusion plates offer high heat conductivity and quick system response » Aluminium heat diffusion plate 1000mm x 390mm x 0.5mm 10/50 commercial grade aluminium to incorporate 16mm PEX pipe SYSTEM INSTALL 1. EPS insulation panel installed directly on to subfloor according to system design. (Insulation specification in accordance with required thermal performance and current building regulations. Rigid EPS panel available from 25mm depth) 2. Aluminium heat diffusion plate to be fixed directly into pre-grooved EPS insulation panel 3. 16mm PEX pipe to be installed directly into heat diffusion plate channels in continuous lengths from distribution manifold spaced according to underfloor heating design 4. EPS insulation panel to be routed as required allowing pipe installation in accordance with design layout 5. Pipework to be pressure tested and remain under pressure FLOATING PLATED EPS SYSTEM SPECIFICATION BaseTM FLOATING PLATED EPS SYSTEM to incorporate 16mm PEX pipe to be installed to pre-grooved rigid EPS insulation panel. 0.5mm aluminium heat diffusion plate to be fixed directly into pre-grooved rigid EPS insulation panel. Installation and design in accordance with pipe layout design. Finished floor Engineered timber board Aluminium diffusion plate PEX pipe Grooved EPS insulation Sub floor 09 24
  • 14. SYSTEM » BaseTM BATTEN PLATED EPS SYSTEM specifically designed to fit directly to sub-floor construction » 1200mm x 350mm x 25mm pre-grooved EPS insulation installs directly between fixed battens spaced equally to sub floor » Aluminium heat diffusion plate fits directly into pre- grooved EPS panel offering a low system build up of only 30.5mm » Pipework is tightly encased within aluminium heat diffusion plate ensuring even heat distribution across the floor area with EPS panel to counter downward heat loss » Aluminium heat diffusion plates offer high heat conductivity and quick system response » Aluminium heat diffusion plate 1000mm x 390mm x 0.5mm to incorporate 16mm PEX pipe SYSTEM INSTALL 1. EPS insulation panel installed directly on to subfloor between battens according to system design. (Insulation specification in accordance with required thermal performance and current building regulations. Rigid EPS panel available from 25mm depth) 2. Aluminium heat diffusion plate to be fixed directly into pre-grooved EPS insulation panel. 3. 16mm PEX pipe to be installed directly into heat diffusion plate channels in continuous lengths from distribution manifold spaced according to underfloor heating design 4. EPS insulation panel to be routed as required allowing pipe installation in accordance with design layout. 5. Pipework to be pressure tested and remain under pressure BATTEN PLATED EPS SYSTEM SPECIFICATION BaseTM BATTEN PLATED SYSTEM to incorporate 16mm PEX pipe. Pipe to be installed to aluminium diffusion plate and pre-grooved rigid EPS insulation panel. Battens to be fixed to sub floor in accordance with pipe layout design. Engineered timber board Aluminium diffusion plate PEX pipe Grooved EPS insulation Batten Sub floor 10 26
  • 15. SYSTEM » BaseTM ULTRA-LOW EPS SYSTEM specifically designed to fit directly on to sub-floor construction » Pre-grooved foil faced EPS insulation panels offer quick installation with ability to be cut to exact size required in accordance with design » Pre-grooved foil faced EPS panel offering a low system build up of either 13mm or 17mm » Pipework is tightly encased within pre-grooved foil faced EPS panels ensuring even heat distribution across the floor area. Foil faced panel to counter downward heat loss » Pre-grooved foil faced EPS panels offer high heat conductivity and quick system response SYSTEM INSTALL 1. Pre-grooved foil faced EPS panel installed directly on to subfloor according to system design (additional insulation may be required to meet required thermal performance and current building regulations) 2. PEX pipe to be installed directly into pre-grooved foil faced EPS panel 3. PEX pipe to be installed in continuous lengths from distribution manifold spaced according to underfloor heating design 4. Pre-grooved foil faced EPS panel to be routed as required allowing pipe installation in accordance with design layout 5. Pipe work to be pressure tested and remain under pressure ULTRA-LOW EPS SYSTEM SPECIFICATION BaseTM ULTRA-LOW EPS SYSTEM to incorporate 12mm or 16mm PEX pipe to be installed to pre-grooved foil faced EPS insulation panel. PEX pipework to be installed directly into pre-grooved foil faced EPS insulation panel (primer and self leveling compound to be applied prior to tiled finish). Installation and design in accordance with pipelayout design. Finished floor 17mm pre-grooved foil faced EPS insulation 16mm PEX pipe Subfloor Finished floor 13mm pre-grooved foil faced EPS insulation 12mm PEX pipe Subfloor 11 28
  • 16. ULTRA-LOW PANEL SYSTEM Finished floor Screed PEX pipe Screed board Subfloor SYSTEM » BaseTM ULTRA-LOW PANEL specifically designed to fit directly on to sub-floor construction » Pre-routed panels offer quick installation with ability to be cut to exact size required in accordance with design » PEX pipe fits directly into pre-routed panel offering a low system build up from only 15mm » Pipework is tightly encased within pre-routed panel ensuring even heat distribution across the floor area. » Panels offer quick system response SYSTEM INSTALL 1. Pre-routed panels installed directly on to subfloor according to system design (additional insulation to be installed below panel in accordance with required thermal performance and current building regulations) 2. PEX pipe to be installed directly into pre-routed panels in continuous lengths from distribution manifold, spaced according to underfloor heating design 3. Additional blank panels to be routed as required allowing pipe installation in accordance with design layout 4. Pipework to be pressure tested and remain under pressure SPECIFICATION BaseTM ULTRA-LOW PANEL SYSTEM to incorporate PEX pipe to be installed to pre-routed panels. Finished floor to be layed directly to panel. Additional screed option for tiled finish. Installation and design in accordance with pipe layout design. 12 30
  • 17. BaseTM PEX PIPE BaseTM PEX is a high performance pipe that is both flexible and extremely resilient. Constructed from a superior cross linked polyethylene, our pipe benefits from a much higher resistance to both heat and pressure compared to other forms of PEX pipe, resulting in much greater strength and durability. » 100% impermeable oxygen diffusion barrier » Operational temperature up to 90 ºC » Extremely flexible pipe for ease of installation » Maintenance free » Meets EN ISO 15875 standard SYSTEM CONTROLS Our comprehensive range of innovative system controls offer the ultimate in both stylish, discreet design, coupled with intuitive, user friendly operation. Our slimline series of thermostats offer an extensive range of control options, to include touch-screen, wireless, wifi, networked and via mobile app (Apple and Android platforms) MANIFOLDS Our precision engineered BaseTM Nickel plated manifold offers complete system control through the utilisation of adjustable flow gauges, mixing valve and ‘A’ rated pump. The distribution of low temperature warm water is precisely regulated to each individual zone of the underfloor heating system. MANIFOLDS AND CONTROLS 32
  • 18.