SlideShare a Scribd company logo
1 of 68
specification
catalogue
2013
water efficient washroom controls
Cistermiser has been designing and
manufacturing a range of high
quality, cost effective, water efficient
products for over 30 years.
our early days
The company developed its first product,
a hydraulic urinal flush control valve in 1976
at a time when there were no regulations
stipulating that companies had to minimise
water consumption in the washroom.
The desire to conserve water and promote
washroom hygiene is the key driver of
Cistermiser’s ongoing investment in new
product development.
research and
development
Two low pressure derivatives of the
hydraulic valve were developed during
the 1980s before the company added its
first domestic product, a limescale
prevention device called Combimate,
to its range in 1987.
Investment in R&D led to the development
of electronic technologies and the
company launched a complete washroom
control and the infrared urinal flush control
valve in the early 1990s.
In recent years, the company’s product
portfolio has expanded into all areas of the
washroom with the addition of a WC
flushing device, a mains-flushing urinal
control, a complete anti-vandal range and a
series of infrared taps and spouts.
cistermiser today
Today the Cistermiser name is synonymous
with quality and reliability and has become
a generic term for all urinal flush controls.
We now offer solutions for commercial,
industrial and public sector washroom
environments where security, hygiene and
cost reductions are required.
contents
welcome 4
Products and Services 4
Water Efficiency 5
Our Commitment 5
BREEAM 6
SECTORS
education 9
Products 10
Case Study 12
BREEAM Education 13
healthcare 15
Products 16
Case Study 18
BREEAM Healthcare 19
secure environments 21
Products 21
BREEAM Prisons 22
public, commercial & hospitality facilities 23
Products 24
BREEAM 27
OUR PRODUCTS
urinal flushing 33
Hydraulic Valve 34
Infrared Control Valve (IRC valve) 36
Anti-Vandal Urinal Flush Control 38
Direct Flush 39
wc flushing 43
Easyflush (Wave and Walkaway) 44
Easyflush Direct 48
Anti-Vandal WC Flushing 52
taps and showers 53
Novatap 54
Novaspout 54
Vectatap 54
Vectaspout 54
Anti-Vandal taps 58
Anti-Vandal showers 58
total washroom control systems 59
Anti-Vandal Range Valve 60
Sensazone 63
SECTORSOURPRODUCTS
4
…to our 2013 specification catalogue, designed as a guide
to help you choose the most appropriate product for your
particular application.
welcome…
Cistermiser produces a range of products which control all the water outlets in a commercial washroom.
Several of our products can also be used in domestic applications.
products & services
urinal flush control
Our range of urinal flush control
valves includes the hydraulic urinal
flush control valve, and electronic
infrared valve for use in urinal
installations where a cistern is used
to flush the urinals.
The direct flush urinal valve is an
‘intelligent’ product which detects
when someone is using the urinal
and only flushes after that person has
left it. This valve has been specifically
designed for flushing urinals directly
from the (mains) water supply.
WC flush control
easyflush is a no-touch WC flushing
valve with dual flush from a single
sensor. We also offer a secure av
(anti-vandal) touch button controlled
WC flush valve.
taps and showers
Cistermiser’s range of infrared taps,
the novatap, novaspout and
vectaspout, can be either basin or
panel-mounted. Our av (anti-vandal)
taps and showers provide a robust
solution for environments where
vandalism is a concern.
av range
This is a secure range of products
designed for use in high risk and
challenging environments. This
complete washroom solution offers
robust, heavy duty, vandal-proof
shower spouts, basin spouts, urinal
and WC flushing.
washroom control
Cistermiser’s sensazone range
controls the water supply, lighting and
extractor fans within the washroom.
Our sensazone product controls the
supply of hot, cold and rain or grey
water into the washroom, isolating the
supplies in vacant periods.
limescale prevention
Cistermiser also manufactures the
combimate, a limescale prevention
device, for use with combination
boilers and whole house water
heaters in domestic settings.
Please ask us for details.
All of Cistermiser’s products can be
used in conjunction with rain or grey
water where applicable.
sales
Our Sales team can answer any pre-
installation queries regarding our
products, to discuss specific
requirements or arrange site surveys.
technical support
Our Technical Support team is
trained to deal with any technical
queries or issues with our products
post-installation. The team also
conducts CPD presentations
covering washroom management,
the water regulations and BREEAM
compatibility.
quality & warranty information
All Cistermiser products are WRAS
approved and the company is ISO
9001:2008. All products have a one
year parts only warranty from the
date of manufacture. The warranty
can be extended, free of charge, to
three years from date of installation
by returning the completed
warranty card after commissioning
the product.
The catalogue is divided into two main sections.
sector specific section
Detailed information about the suitability of our
products for a variety of environments ranging
from school and healthcare washrooms to
secure facilities.
product section
A comprehensive technical overview of all our
products, along with up-to-date information on
water conservation, hygiene requirements and the
environmental performance of buildings.
5
“The key to water
efficiency is
reducing waste,
not restricting use.”
WATERWISE
Despite the chronic shortage of
water storage facilities in the UK,
each individual still uses
approximately 150 litres per day;
this figure increases to over 3,400
litres per person every day when
embedded water consumption
is considered.
• Water usage in the UK has been
rising by 1% a year since 1930.
• 1.2 billion litres of water are
flushed needlessly away every
day in the UK.
• Urinals operating without flush
controls can use up to 160,000
litres of water a year.
• Millions of WCs installed in the UK
have a flush capacity of 13 litres
or even more.
• A conventional tap installed on
typical commercial premises can
use over half a million litres of
water a year.
Water Efficiency Rating IRC DF None
very water efficient
not water efficient
0-30
30-60
60-90
90-120
120-160
23
28
158
Note: in 1,000s of litres
water efficiency
our commitment
Cistermiser has a long established record of dedication to
conserving water; our first water saving product was launched
soon after the 1976 drought. We have always recognised the
need to reduce water wastage and our product range reflects
this commitment. Our infrared range of products has been
recognised as “water efficient” under the Waterwise Marque and
the BMA Water Efficient Product Labelling Scheme (WEPLS).
We have developed a water efficiency rating chart to show
just how much water our products save compared to standard
products. The chart below indicates the achievable savings as
a result of installing one of our urinal flush controls (see pages
34 and 36 for more details). These details are available for all
of our products in the product section of this catalogue.
6
These versions all look at the same broad range
of environmental impacts:
• Management
• Health and Wellbeing
• Energy
• Transport
• Water
• Material and Waste
• Land use and Ecology
• Pollution
Credits are awarded in each of the above
areas according to performance. A set of
environmental weightings then enables the
credits to be added together to produce a single
overall score. The building is then rated on a
scale of:
PASS, GOOD, VERY GOOD, EXCELLENT or
OUTSTANDING and a certificate is awarded to
the development.
As part of our commitment to water conservation,
we have assessed how our products can help a
building design achieve BREEAM credits and
hence a higher overall BREEAM rating. To achieve
an OUTSTANDING rating for example, a building
design will need to obtain 2 credits under the Wat
1 category. You will find further details, which can
also be used to justify your choice of products, in
the sector section of the catalogue under:
• Education
• Healthcare
• Secure Environments
• Public, Commercial and Hospitality Facilities
BREEAM (Building Research Establishment Environmental
Assessment Method) buildings can be used to assess the
environmental performance of any type of building (new and existing).
Standard versions exist for common building types. Less common
building types can be assessed against tailored criteria under the Bespoke
BREEAM version. Buildings outside the UK can also be assessed
using BREEAM International.
The BREEAM Pre-Assessment estimators
outline the requirements to achieve BREEAM
credits. To download the estimators you
will need to register on:
www.breeam.org/index.jsp
helpful links to BREEAM and Cistermiser information:
Further information on the BREEAM
categories and how Cistermiser products
can help achieve BREEAM credits within the
categories is available to view and download
on: www.cistermiser.co.uk/breeam.aspx
7
education
Products
Case Study
BREEAM Education
healthcare
Products
Case Study
BREEAM Healthcare
an extensive range of products each with
a comprehensive technical overview
sectors
p.9 p.15
secure
environments
Products
BREEAM Prisons
public, commercial
& hospitality facilities
Products
Case Study & BREEAM
p.21 p.23
0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk
SECTORS
8
Cistermiser recognises the demanding requirements of
educational settings and has developed products to combat
common problems within washrooms, such as poor hygiene
practices and water wastage caused by accidental and
deliberate vandalism.
automated solutions for
school washrooms
education 9
education
0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk
SECTORS
These are the minimum standards that the Department for
Education would expect to be adopted in a school:
• The taps should be wall mounted to avoid the
dirt and germ build up that can occur around
deck-mounted taps.
• Taps should be WRAS approved.
Source: Standard specifications, layouts and dimensions
• The taps should be sensor operated and turn
off automatically with less than one litre of use.
This will help avoid the germ transfer that
happens with more traditional touch operated
mechanisms. It will also save water and
minimise the risk of potential flooding.
novaspout
10
infrared taps
The novaspout and vectaspout are no-touch infrared
panel-mounted basin outlets. They are activated when a
user’s hands are presented to the infrared sensor.
The outlets are fully automated and are activated by the
movement of the user’s hands. Periodic hygiene
rinses reduce the risk of microbial contamination such
as legionella.
Cistermiser also makes the novatap and vectatap, deck-
mounted basin outlets for simple retrofit or where panel
mounting is not an option.
The novatap, novaspout, vectatap and vectaspout
automatically switch off two seconds after the user’s
hands are moved away, for example, while applying soap
after wetting the hands, eliminating the wasted water
from excessive run-on as happens with percussion
(“push”) or traditional taps. The anti-vandal feature closes
the taps after 60 seconds of continuous flow. This is
helpful if, for example, chewing gum is placed over
the sensor.
SECTORS
easyflush wc flush valve
The easyflush wave and walkaway valves provide
no-touch flushing and filling of the WC. The wave is
operated by the user passing their hand in front of the
sensor while the walkaway is automatically activated
when the user stands up or leaves the cubicle. The
risk of smells associated with residue left in WCs when
users forget or omit to flush is therefore eliminated.
The easyflush inlet float valve operates with a delayed
action, which only allows the cistern to begin refilling
after it has been completely emptied and the
outlet valve has closed. easyflush also includes
programmable part and full flushes, which allows
the installer to minimise the amount of water
required during each flush, but ensures sufficient
water is provided.
direct flush urinal flush valve
The direct flush provides a no-touch flush control to
each urinal individually from the mains water supply.
The direct flush valves provide intelligent automatic
flushing of each individual urinal after use, ensuring
the highest level of hygiene from the minimum volume
of water. The flush of water rinses the urinal bowl and
changes the contents of the waste trap, eliminating the
risk of undesirable smells. Each flush only uses 0.5 litres
of water. The valves are especially effective in reducing
water wastage in washrooms with low frequency usage.
sensazone
sensazone is a simple but effective management
system to control the water, lighting and extractor fans
within the washroom.
Occupancy is constantly monitored by up to 10 PIR
sensors strategically placed throughout the
washroom. When someone enters the washroom, all
services controlled by sensazone are activated; the
hot and cold water solenoids open, lighting is
switched on (if necessary), the extractor fans start
turning and the internal timers begin counting.
Every service system in the washroom is set to run for
a fixed time or ‘service cycle’, which is determined by
the installer. If no further movement is detected the
washroom services are shut down.
As sensazone controls water at its entry point, the
water is prevented from passing uncontrolled through
any defective or damaged outlet, eliminating the risk of
wastage or flooding during vacant periods.
sensazone
direct flush
discreet
urinals in school
washrooms
As highlighted by the Bog Standard
campaign, the use of urinals in schools
can be problematic for pubescent
boys. Cistermiser recognises these
issues and supports the need for
individual partitioning and improved
hygiene conditions at urinal bowls.
education 11
easyflush
SECTORS
case study
cathays high school, cardiff
location
Cathays High School is a mixed comprehensive school for
11 to 19 year olds serving the heart of Cardiff. As is the case
with many progressive schools, Cathays High elects a
School Council made up of elected representatives from all
year groups. They meet to discuss and act upon ideas to
improve the school. One wish passed on from all age groups
was to seek a method of improving the flushing of toilets.
the project
Research into ways of remedying this problem led to
consideration of Cistermiser’s ‘hands free’ flushing system
already in successful use in other schools and colleges.
Mr Gavin Bryant, the Schools Mechanical Advisory Officer
for Cardiff County Council suggested that Cistermiser be
invited to demonstrate the easyflush system, and the
company immediately sent a team to the school to review
the problem first hand. The suggestion of using the Cistermiser
easyflush system in the usual ‘wave’ mode, where the user
simply passes a hand in front of the infrared sensor to
activate a flush, was not considered wholly satisfactory.
It was felt that this could be easily ignored as with manual
flushing, so the team went back to talk to Cistermiser’s
R & D Department, which was already investigating other
methods of flush activation.
the solution
The need was for a flush system that could be activated
automatically without any effort on the part of the user.
Cistermiser’s solution was to adopt the easyflush system
but with walkaway operation. Under this new mode of
operation a flush is automatically triggered whenever a
user gets up or walks away from the toilet. However it can
also be activated by the user bringing their hand toward
the sensor.
The IR sensors operate on a dual flush system, delivering
a part flush if the user leaves within 40 seconds or a full flush
if that period is exceeded. The ‘walkaway’ method is
simple, hygienic and economical since it restricts water
use to a minimum.
As a trial the Cistermiser Team fitted four of the cubicles
used by the boys with easyflush valves with walkaway
flush activation, and it has certainly solved the problem
highlighted by the students. The school was particularly
pleased with the co-operation and personal service from
Cistermiser, from the initial contact to the project’s
completion. The easyflush toilets have now been in
operation for nearly two years and have resulted in cleaner
toilets and a more hygienic environment for the pupils.
12
SECTORS
infrared products
The Cistermiser infrared range can help a building design gain BREEAM credit ratings under the Water and
Health & Wellbeing categories.
performance
• Standard 6 litre full flush with an
adjustable part flush giving an effective
flush volume of 4.5 litres.
• Provides a linked flush and fill function
of fittings (delayed action inlet valve
operation).
• Full flush adjustable to 4 litres with a
subsequent reduction in part flush giving
an effective flush volume of 3 litres.
• Each flush uses less than 0.5 litres.
• Flush arrest function to reduce water
consumption further during periods of
high use.
• Programmable for flush duration and sensing
range, and has a hygiene rinse function.
• Cleaner’s function.
• Regulated flow of either 5 litres or 3.5 litres
per minute.
• Programmable run-on.
• Used with Thermostatic Mixing Valves,
the periodic hygiene rinse function prevents
the warm, mixed water from stagnating.
• Reduces the risk of microbial contamination
such as legionella.
BREEAM category
Wat 1
Where evidence provided
demonstrates that the specification
includes taps, urinals, WCs and
showers that consume less
potable water in use than standard
specifications for the same type
of fittings.
Hea 12
Where hot and cold water systems
have been designed or actions
taken to minimise risks of microbial
contamination.
cistermiser product
easyflush WC valve
direct flush
(Discreet and Accessible)
urinal control valve
novatap, novaspout,
vectatap and vectaspout
basin outlets
novatap, novaspout,
vectatap and vectaspout
basin outlets
BREEAM Education helps
schools and further education
colleges to set environmental
targets for new and refurbished
education buildings.
Please refer to our website www.cistermiser.co.uk/breeam for further information on the BREEAM categories and a more
detailed explanation of how the credits are achieved.
It also serves as a useful tool for designers by demonstrating the
environmental performance of their designs. Assessments can be
carried out at the design stage and verified post-construction for
primary and secondary schools and further education colleges
including the following:
• New schools • Major refurbishment projects • Extensions
The development of BREEAM Education was driven by the
Sustainable Development Action Plan, which called for both new
build and refurbishment projects to achieve no less than a
BREEAM ‘VERY GOOD’ rating.
education 13
performance
• Controls the lighting in the washroom zone
so that lights are on only when users are
present.
• Lighting is automatically switched on when
a user is detected.
• A daylight sensor is fitted within the unit to
provide switching only when the level of
natural lighting is insufficient.
• The system offers proximity shut off of both
hot and cold water supplies to the washroom
• The unit provides proximity shut off for the
hot and cold and rain/grey water supply.
BREEAM category
Hea 6
Where evidence provided demonstrates
that, in all relevant building areas,
lighting is appropriately zoned and
occupant controllable with the option
for commonly required lighting settings
to be selected quickly and easily.
Ene 4
Where energy efficient external luminaires
are fitted and all light fittings are
controlled for the presence of daylight.
Wat 4
Where evidence is provided to
demonstrate that proximity detection
shut off is provided to the water
supply to all toilet areas.
cistermiser product
sensazone
sensazone
sensazone
sensazone
washroom control
The Cistermiser sensazone range helps building designs gain BREEAM credit ratings under three distinct categories as
well as providing additional washroom management functions.
performance
• Standard 6 litre full flush with an adjustable
part flush giving an effective flush volume of
4.5 litres.
• Full flush adjustable to 4 litres with a
subsequent reduction in part flush giving
an effective flush volume of 3 litres.
• Each flush uses less than 0.5 litres.
• Flush arrest function to reduce water
consumption further during periods of high use.
• Programmable flush duration.
• Hygiene rinse function.
• Basin outlet flow control set at 1.7 litres
per minute.
• Shower outlet flow control set at 7 litres
per minute.
• Used with Thermostatic Mixing Valves, the
periodic hygiene rinse function prevents the
warm, mixed water from stagnating.
• Reduces the risk of microbial contamination
such as legionella.
BREEAM category
Wat 1
Where evidence provided
demonstrates that the specification
includes taps, urinals, WCs and
showers that consume less potable
water in use than standard
specifications for the same type of
fittings.
Hea 12
Where hot and cold water systems
have been designed or actions taken to
minimise risks of microbial contamination.
cistermiser product
av range control of
easyflush WC valve
av range control of
direct flush urinal
control valve
av basin outlets
and showers
av basin outlets
and showers
av range
The Cistermiser av range can help a building design achieve specific BREEAM credits under the Water and Health & Wellbeing
categories whilst providing a robust anti-vandal, anti-ligature water control package for high risk and hard use environments.
Other BREEAM compatible products
14
All of Cistermiser’s healthcare products use no-touch infrared
technology and therefore provide a completely automated
solution for healthcare washrooms and help to reduce cross-
contamination and infection.
automated solutions for
healthcare washrooms
healthcare 15
healthcare
0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk
SECTORS
infrared taps
The novatap, novaspout, vectatap and vectaspout
are no-touch infrared deck and panel mounted basin
outlets. They are activated when a user’s hands are
presented to the infrared sensor. The outlets are fully
automated and are activated by the movement of the
user’s hands. Periodic hygiene rinses reduce the risk
of microbial contamination such as legionella.
The infrared taps and spouts automatically switch off
two seconds after the user’s hands are moved away,
eliminating the wasted water from excessive run-on as
happens with percussion (“push”) or traditional taps.
All spouts are compliant with HTM64 when used with
a Thermostatic Mixing Valve (TMV) and the 3.5l/min
laminar flow outlet has been designed specifically for
healthcare applications.
Healthcare associated infections
(HCAIs) in England are estimated
to cost the National Health
Service £1,000 million annually.
According to a report by the
National Audit Office, improved
hand hygiene is the primary action
required to reduce healthcare
associated infection.
Cistermiser understands the
importance of hand hygiene
within health care settings and
has developed a range of infrared
taps to help staff improve
compliance with new guidelines.
The range is also perfectly suited
to patient and visitor areas within
healthcare settings.
novaspout
16
SECTORSeasyflush dual flush wc valves
The easyflush wave and walkaway valves provide
no-touch flushing and filling of the WC. The wave
is operated by the user passing their hand in front
of the sensor while the walkaway is automatically
activated when the user stands up or leaves
the cubicle.
The easyflush valves include programmable part
and full flushes, which minimises the amount of
water used.
direct flush urinal flush
control valves
The direct flush valves provide ‘intelligent’ automatic
flushing of each individual urinal after use, ensuring
the highest level of hygiene from the minimum
volume of water. The flush of water removes
any waste immediately, eliminating the risk of
undesirable smells.
Each flush only uses 0.5 litres of water. The valves
are especially effective in reducing water wastage
in washrooms with low frequency and irregular
usage patterns.
direct flush discreet
healthcare 17
easyflush wave
case study
treloar college
location
Treloar College, for students aged 16 or over, with physical
disabilities, is specially designed not only to educate but also
to help these young people to integrate into society.
Situated in Holybourne near Alton in Hampshire, Treloar
takes students from all over the country and provides a
positive, supportive environment in which they can develop
as adults. Students have a wide range of physical
conditions, including those that have an associated
learning difficulty.
The college also caters for students with degenerative or
life-limiting conditions. Many students who come to the
College choose to board and because the halls are
managed in a number of small units, staff and students
have the opportunity to get to know each other well.
There are five halls of residence, each with space for
approximately 32 students, and each hall has its team of
highly qualified support staff.
the project
Brewer House was built in July 2008 and it includes a
£3.5million hall with 30 en-suite bedrooms and three
communal bathrooms. It was designed by Fleet architectural
practice McAllen & Penfold and built by Wilding Butler
Construction Ltd of Winchester. Cistermiser worked closely
with the architects and assisted with the preparation of the
specification to ensure the appropriate user-friendly
equipment was specified. Cistermiser’s easyflush system
was selected in 16 of the bathrooms.
the solution
This hands-free system completely eliminates the need to
rotate a handle or apply pressure on a button. It has proved
immensely popular in situations where elderly or less able
people are involved, and also in all sorts of public
installations for its damage and vandal-proof qualities.
easyflush is a WRAS approved, hygienic and simple-to-use
product that employs a single infrared sensor to operate a
dual flush WC valve. The user needs only to pass his or her
hand slowly in front of the sensor for a part flush or hold it
there for more than a second to obtain a full flush.
A 12-hour hygiene flush is fitted as standard. The system
conserves water as much as possible due to its default
(programmable) part flush. In the case of the College,
savings of 47% are expected both on costs and water
consumption. The easyflush units supplied were installed
using battery power, which makes them very quick to install
and easy to maintain.
McAllen & Penfold then put Cistermiser in touch with Tom
Dunsford of Accolade Building Services, who arranged a site
visit so that the optimum positioning of the cisterns to be
used could be established. Cistermiser also tested one of
the unusually small cisterns in their workshop to ensure that
it was fully compatible with the easyflush system.
This hands-on approach continued even after all the valves
were installed. A representative of Cistermiser visited the
College’s Facilities Department, gave a presentation on the
easyflush product and answered questions on a wide
range of topics associated with the product. The easyflush
system is operating perfectly and has been greatly
appreciated by the students. No direct phone calls have
been necessary.
18
SECTORS
infrared products
The Cistermiser infrared range of products can help a healthcare building design gain BREEAM credit ratings
under the water category and offers additional health, safety and maintenance benefits.
performance
• Standard 6 litre full flush with an
adjustable part flush giving an effective
flush volume of 4.5 litres.
• Provides a linked flush and fill function
of fittings (Delayed action inlet valve
operation).
• Full flush adjustable to 4 litres with a
subsequent reduction in part flush giving
an effective flush volume of 3 litres.
• Each flush uses less than 0.5 litres.
• Flush arrest function to reduce water
consumption further during periods of
high use.
• Programmable for flush duration, sensing
range and has a hygiene rinse function.
• Cleaner’s function.
• Regulated flow of either 5 litres or 3.5 litres
per minute.
• Programmable run-on.
• Used with Thermostatic Mixing Valves, the
periodic hygiene rinse function prevents
the warm, mixed water from stagnating.
• Reduces the risk of microbial
contamination such as legionella.
BREEAM category
Wat 1
Where evidence provided
demonstrates
that the specification includes taps,
urinals, WCs and showers that
consume less potable water in use
than standard specifications for the
same type of fittings.
Hea 12
Where hot and cold water systems
have been designed or actions taken
to minimise risks of microbial
contamination.
cistermiser product
easyflush WC valve
direct flush
(Discreet and Accessible)
urinal control valve
novatap, novaspout,
vectatap and
vectaspout basin outlets
novatap, novaspout,
vectatap and
vectaspout basin outlets
Note: Waterless urinals. Due to overriding health and safety concerns in some healthcare facilities, the specification of
waterless urinals may not be feasible. In such cases, the lowest hygienic water consumption by urinals can be achieved with
other products such as ultra low flush volume or infrared proximity-sensing urinal flush controls. Cistermiser’s Direct Flush
products will deliver the appropriate levels of hygiene and water consumption and earn the same BREEAM credits.
Please refer to our website www.cistermiser.co.uk/breeam for further information on the BREEAM categories and a more
detailed explanation of how the credits are achieved.
BREEAM Healthcare can be used
to assess all healthcare buildings
containing medical facilities at
different stages of their lifecycles.
healthcare 19
BREEAM category
Hea 6
Where evidence provided demonstrates
that lighting, in all occupied areas, is
zoned to allow separate control.
Hea 07
Where lighting controls allow commonly
required lighting settings to be made
quickly and easily by building occupants.
Ene 4
Where energy efficient external luminaires
are fitted and all light fittings are
controlled for the presence of daylight.
Wat 4
Where evidence is provided to
demonstrate that proximity detection
shut-off is provided to the water
supply to all urinals and WCs.
cistermiser product
sensazone
sensazone
sensazone
sensazone
washroom control
The Cistermiser sensazone range helps building designs gain BREEAM credit ratings under four distinct categories as
well as providing additional washroom management functions.
performance
• Standard 6 litre full flush with an adjustable
part flush giving an effective flush volume of
4.5 litres.
• Full flush adjustable to 4 litres with a
subsequent reduction in part flush giving an
effective flush volume of 3 litres.
• Each flush uses less than 0.5 litres
• Basin outlet flow control set at 1.7 litres
per minute.
• Shower outlet flow control set at 7 litres
per minute.
• Used with Thermostatic Mixing Valves, the
periodic hygiene rinse function prevents the
warm, mixed water from stagnating.
• Reduces the risk of microbial contamination
such as legionella.
BREEAM category
Wat 1
Where evidence provided
demonstrates that the specification
includes taps, urinals, WCs and
showers that consume less potable
water in use than standard
specifications for the same type
of fittings.
Hea 12
Where hot and cold water systems
have been designed or actions taken
to minimise risks of microbial
contamination.
cistermiser product
av range control of
easyflush WC valve
av range control of
direct flush urinal
control valve
av basin outlets
and showers
av basin outlets
and showers
av range
The Cistermiser av range can help a building design achieve specific BREEAM credits under the Water and Health & Wellbeing
categories whilst providing a robust anti-vandal, anti-ligature water control package for high risk and hard use environments.
Other BREEAM compatible products
performance
• The system controls the lighting in the
washroom zone so that lights are on only
when users are present.
• Users not familiar with the facility are also
catered for by means of the PIR sensor
lighting, which is automatically switched on
when a user is detected.
• The system contains a daylight sensor to
provide switching only when the level of
natural lighting is insufficient.
• Controls proximity shut-off of the water
supply to the urinals and WCs by means of
the PIR sensor detecting occupancy and
providing signals to close the control valves
during periods of no occupation.
20
anti-vandal range
Cistermiser’s av range is easy to install and
is designed to offer the highest possible levels of
tamper-proof security and remote control, while at
the same time saving water and minimising running
costs through the use of latching solenoids.
The user interface is a stainless steel encased piezo
touch button which is fitted flush with the mounting
surface. The basin spouts and shower heads are also
made from stainless steel and come with anti-rotation
washers and pins. There is a range of specially
contoured anti-ligature versions of the basin spouts
and shower heads for use in locations where self-harm
is a real concern.
The highly versatile av range includes three styles of
shower head, two styles of wall mounted basin spout,
a combined flush and fill valve for WC cisterns with
the option of supply within a pre-configured cistern,
a direct flushing urinal valve, a six channel controller
and a power supply unit.
secure environments 21
anti-vandal range of
washroom controls
secure
environments
Cistermiser has developed a range of
washroom products to meet the
demanding requirements of environments
such as prisons and secure hospitals.
Our products have been designed to
impede deliberate vandalism, acts of
aggression towards others and attempts
to self-harm. The entire range of products
provides vandal-resistant touch controlled
water delivery to washrooms.
0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk
SECTORS
performance
• Standard 6 litre full flush with an adjustable
part flush giving an effective flush volume of
4.5 litres.
• Full flush adjustable to 4 litres with a
subsequent reduction in part flush giving an
effective flush volume of 3 litres.
• Each flush uses less than 0.5 litres.
• Basin outlet flow control set at 1.7 litres
per minute.
• Shower outlet flow control set at 7 litres
per minute.
• Used with Thermostatic Mixing Valves, the
periodic hygiene rinse function prevents the
warm, mixed water from stagnating.
• Reduces the risk of microbial contamination
such as legionella.
BREEAM category
Wat 1
Where evidence provided
demonstrates that the specification
includes taps, urinals, WCs and
showers that consume less potable
water in use than standard
specifications for the same type
of fittings.
Hea 12
Where hot and cold water systems
have been designed or actions
taken to minimise risks of
microbial contamination.
cistermiser product
av range control of
easyflush WC valve
av range control of direct
flush urinal control valve
av basin outlets
and showers
av basin outlets
and showers
washroom control range
The Cistermiser washroom control range helps building designs gain BREEAM credit ratings under the Water category
as well as providing additional washroom management functions.
performance
• Controls proximity shut-off of the water
supply to the urinals and WCs by means of
the PIR sensor detecting occupancy and
providing signals to the control valves during
periods of no occupation.
BREEAM category
Wat 4
Where evidence is provided to
demonstrate that proximity
detection shut off is provided to
the water supply to all urinals
and WCs.
cistermiser product
sensazone
BREEAM prisons can assess high and standard security prisons, young
offenders’ institutions, local prisons and women’s prisons at the design
stage and post construction.
av range
The Cistermiser av range can help a building design achieve specific BREEAM credits under the water category whilst
providing a robust anti-vandal, anti-ligature water control package for high risk and hard use environments.
22
All of Cistermiser’s products are suitable for washrooms that
provide services to the general public.
including offices, leisure centres,
public and industrial buildings
public commercial &
hospitality facilities 23
public,
commercial &
hospitality facilities
0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk
SECTORS
urinal flushing
The hydraulic valve is an automatic urinal flush control
valve. The valve uses a simple patented mechanism
which prevents water waste by ensuring that the
auto-flush cistern is only filled, and can only flush,
when the washroom is used.
The infrared urinal flush control (IRC) valve
automatically manages the supply of water to a urinal
cistern. The PIR sensor detects movement and
activates the solenoid valve, only allowing water into a
urinal cistern when the washroom is in use. This
reduces water consumption by up to 80%. The
12-hour hygiene improves cleanliness.
Cistermiser’s products deliver a range of benefits into larger
washrooms and municipal facilities.
24
av urinal flush
The av urinal flush control valve is part of a complete
washroom management system, the av range. The
touch-activated piezo button is the only visible part of the
system. It is ligature resistant and has no moving parts.
The piezo button cannot therefore be rotated or removed.
When the button is touched it causes an electronically
operated valve to open and allow water to flush the urinal.
The direct flush valves provide ‘intelligent’
automatic flushing of the individual urinal after
use, ensuring the highest level of hygiene from
the minimum volume of water. The flush of
water removes any waste immediately,
therefore eliminating the risk of undesirable
odours or build-up of calcium urate in the trap.
reduced water consumption
Our urinal cistern flushing products control water
consumption in gents’ washrooms.
improved hygiene
No-touch controls of all washroom outlets (urinals,
WCs and taps) using infrared technology.
anti-vandal
The av range provides a complete solution where
accidental and deliberate acts of vandalism are
prevalent.
environmentally efficient
Our sensazone range ensures that the water supply,
extractor fans and lighting are only active when the
washroom is in use, thus reducing energy and
eliminating any risk of wastage or undetected flooding.
irc valve (ceiling mount kit)
SECTORS
av range
public, commercial
& hospitality facilities 25
wc flushing
The easyflush wave and walkaway valves provide
no-touch flushing and filling of the WC. The wave is
operated by the user passing their hand in front of the
sensor while the walkaway is automatically activated
when the user stands up or leaves the cubicle.
The av WC flush control valve is part of the av range,
which was designed to offer the highest possible
levels of tamper-proof security and remote control
while at the same time saving water and minimising
running costs through the use of latching solenoids.
The user interface is a stainless steel encased piezo
touch button which is fixed flush with the mounting
surface. This specialist vandal-resistant system
includes a combined flush and fill valve for WC
cisterns with the option of supply within a
pre-configured cistern.
taps and showers
The novaspout and vectaspout are no-touch
panel-mounted basin spouts. They are activated when
a user’s hands are presented to the infrared sensor
which is positioned below the spout.
The robust and highly versatile anti-vandal range of
products includes three styles of wall and ceiling shower
heads and two styles of panel mounted basin spout.
The user interface is a stainless steel encased piezo
touch button which is fixed flush with the mounting
surface. The basin spouts and shower heads are also
made from stainless steel and come with anti-rotation
washers and pins. There is a range of specially
contoured anti-ligature versions of the basin spouts
and shower heads for use in locations where self-harm
is a real concern.
novaspout
washroom control
sensazone is a simple but effective
management system to control
primary services within the washroom.
Occupancy is constantly monitored by
up to 10 PIR sensors strategically
placed throughout the washroom.
When someone enters the washroom
all services controlled by sensazone
are activated; the hot and cold water
solenoids open, lighting is switched on
(if necessary), the extractor fans start
turning and the internal timers begin
counting.
Every service system in the washroom
is set to run for fixed time or ‘service
cycle’ which is determined by the
installer. If no further movement is
detected the washroom services are
shut down. This ensures that the
washroom services remain active
when facilities are required and remain
inactive when they are not.
26
sensazonesensazone
save water
sensazone controls water flow with solenoid
valves. If motion is detected the valves open to
supply water to urinals and cisterns. If no
movement is detected for a pre-set period
(configurable to 15 or 30 minutes), water supply
is cut off.
As sensazone controls water at its entry point,
the water is prevented from passing uncontrolled
through any defective or damaged outlet,
eliminating the risk of wastage or flooding during
vacant periods.
reduce energy
sensazone’s automatic shut-down facility eliminates
unnecessary energy use. This efficiency is achieved
through reducing lighting and extractor fan usage.
The power supply to the lighting will action when
sensazone detects that the washroom is occupied
and when ambient light falls below a level
configurable by the user. Power will continue to be
supplied for either a 0, 15 or 30 minute period,
depending on preference.
Extractor fan operation can also be configured; users
have the option of using sensazone to control the fan
run-on time, or using the fan unit’s own timer facility
(dependent on model selected).
sensazone is supplied with a remote-control handset
that makes setting the system quick and easy.
vectaspout
SECTORS
27
Please refer to our website www.cistermiser.co.uk/breeam for further information on the BREEAM categories and a more
detailed explanation of how the credits are achieved.
Cistermiser products can help gain BREEAM points within the water
section of the BREEAM buildings assessment:
av range infrared products sensazone
BREEAM retail   
BREEAM courts   
BREEAM offices   
breeam retail
BREEAM retail can assess new build or major refurbishment, post-construction, tenant fit-out, existing
(occupied), management and operation.
breeam courts
BREEAM courts can be used to assess and certify the environmental impacts of projects for the following types
of courts: crown, criminal, county, magistrates, family, youth, combined courts and civil justice centres.
breeam offices
BREEAM offices assessments can be carried out on new build, major refurbishment and fit out of both new and
existing office buildings – either vacant or occupied. BREEAM offices is also applicable to BREEAM Industrial
with the exception of Hea 06 and Ene 4 in the working areas of the building, although office areas of an industrial
building will be assessed under BREEAM offices
28
infrared products
The Cistermiser infrared range can help a building design gain BREEAM credit ratings under the Water and
Health  Wellbeing categories.
performance
• Standard 6 litre full flush with an
adjustable part flush giving an effective
flush volume of 4.5 litres.
• Provides a linked flush and fill function
of fittings (Delayed action inlet valve
operation).
• Full flush adjustable to 4 litres with a
subsequent reduction in part flush giving
an effective flush volume of 3 litres.
• Each flush uses less than 0.5 litres.
• Flush arrest function to reduce water
consumption further during periods of
high use.
• Programmable for flush duration, sensing
range and has a hygiene rinse function.
• Cleaner’s function.
• Regulated flow of either 5 litres or 3.5 litres
per minute.
• Programmable run-on.
• Used with Thermostatic Mixing Valves, the
periodic hygiene rinse function prevents
the warm, mixed water from stagnating.
• Reduces the risk of microbial contamination
such as legionella.
BREEAM category
Wat 1
Where evidence provided
demonstrates that the specification
includes taps, urinals, WCs and
showers that consume less potable
water in use than standard
specifications for the same type
of fittings.
Hea 12
Where hot and cold water systems
have been designed or actions taken
to minimise risks of microbial
contamination.
cistermiser product
easyflush WC valve
direct flush
(Discreet and
Accessible) urinal
control valve
novatap, novaspout,
vectatap and vectaspout
basin outlets
novatap, novaspout,
vectatap and vectaspout
basin outlets
public, commercial
 hospitality facilities
28
SECTORS
29
performance
• Controls the lighting in the washroom zone
so that lights are on only when users
are present.
• Lighting is automatically switched on when a
user is detected.
• A daylight sensor is fitted within the unit to
provide switching only when the level of
natural lighting is insufficient.
• The system controls proximity shut off of the
hot and cold water supply to the urinals, taps
and WCs.
• The unit can also provide proximity shut off
for the hot and rain/grey water supply.
BREEAM category
Hea 6
Where evidence provided demonstrates
that, in all relevant building areas,
lighting is appropriately zoned and
occupant controllable with the option
for commonly required lighting settings
to be selected quickly and easily.
Ene 4
Where energy efficient external luminaires
are fitted and all light fittings are
controlled for the presence of daylight.
Wat 4
Where evidence is provided to
demonstrate that proximity detection
shut off is provided to the water supply
to all toilet areas.
cistermiser product
sensazone
sensazone
sensazone
sensazone
washroom control
The Cistermiser sensazone range helps building designs gain BREEAM credit ratings under four distinct categories as
well as providing additional washroom management functions.
performance
• Standard 6 litre full flush with an adjustable
part flush giving an effective flush volume of
4.5 litres.
• Full flush adjustable to 4 litres with a
subsequent reduction in part flush giving
an effective flush volume of 3 litres.
• Each flush uses less than 0.5 litres
• Programmable flush duration.
• Hygiene rinse function.
• Cleaner’s function.
• Basin outlet flow control set at 1.7 litres
per minute.
• Shower outlet flow control set at 7 litres
per minute.
• Used with Thermostatic Mixing Valves, the
periodic hygiene rinse function prevents the
warm, mixed water from stagnating.
• Reduces the risk of microbial contamination
such as legionella.
BREEAM category
Wat 1
Where evidence provided
demonstrates that the specification
includes taps, urinals, WCs and
showers that consume less potable
water in use than standard
specifications for the same type of
fittings.
Hea 12
Where hot and cold water systems
have been designed or actions taken
to minimise risks of microbial
contamination.
cistermiser product
av range control of
easyflush WC valve
av range control of
direct flush urinal
control valve
av basin outlets
and showers
av basin outlets
and showers
av range
The Cistermiser av range can help a building design achieve specific BREEAM credits under the Water and Health  Wellbeing
categories whilst providing a robust anti-vandal, anti-ligature water control package for high risk and hard use environments.
30
Cistermiser has many years of experience working with
a wide range of industries, and our expert team is
always on hand to offer advice on the best solutions for
your sector.
Our case studies show how we frequently use our
expertise to create bespoke solutions for our
customers, and we’d be happy to discuss your needs.
For more information, get in touch with Cistermiser today:
call 0118 969 1611
email sales@cistermiser.co.uk
visit cistermiser.co.uk
our sectors
31
urinal flushing
Hydraulic Valve
Infrared Control Valve (IRC Valve)
AV Urinal Flush Control
Direct Flush
wc flushing
Easy Flush (Wave and
Walkaway)
AV WC Flushing
taps and showers
Novatap  Novaspout
Vectatap  Vectaspout
AV taps  AV showers
an extensive range of products each with
a comprehensive technical overview
our products
p.33 p.43 p.53
total washroom
control systems
AV Range Valve
Sensazone
p.59
0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk
OURPRODUCTS
32
urinal flushing 33
urinal flushing
hydraulic valve irc valve
anti-vandal urinal direct flush
0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk
OURPRODUCTS
• Automatic urinal flush control
• Unique patented hydraulic mechanism – no electrical
supply or batteries required
• Industry leader with half a million already installed
• ‘Fit and forget’ quality and reliability
• Hygiene flush option for periods of non-use
• Ensures compliance with the Water Regulations
• On DEFRA’s ECA Water Technology List; purchase
and installation are tax deductible
reduces water consumption
and washroom odours
hydraulic valve
urinal flush control valve
The hydraulic valve is an automatic urinal
flush control valve. The valve uses a simple
patented mechanism which prevents water
waste by ensuring that the auto-flush cistern
is only filled, and can only flush, when the
washroom is used.
how it works
The Cistermiser hydraulic valve is installed on the supply pipe to
the urinal cistern. The valve is activated by short-term pressure
drops created by use of taps or WCs on the same supply.
The valve is normally closed; when it is activated it opens and
water passes to the urinal cistern until the pressures on both
sides of the valve are equalised. When the cistern is full, the
auto-siphon will flush.
product information
• The valve is installed on the supply
pipe to the urinal cistern.
• The installer or user can adjust the
time the valve remains open and
therefore how long the cistern
takes to fill and how much water is
used. When the washroom is not
being used the water supply
pressure remains constant and the
valve remains closed, preventing
water passing into the cistern.
• The cistern can therefore only
flush during periods when the
washroom is in use, eliminating
unnecessary water consumption
and cost.
34
specification wording
The mechanical contractor shall supply and install a
urinal flushing device of the ‘Cistermiser Hydraulic Valve’
type on the supply pipe to the urinal cistern,
as shown on the drawing.
The flushing control device shall be a mechanical,
hydraulic device operated by changes in system
pressure due to demand on connected water services
within the washroom.
standard valve
The flushing control device shall be suitable for supply
system pressures of between 0.5 and 6.0 bar (typically
either mains water or tank-fed systems above 5m head).
low pressure valve
The flushing control device shall be suitable for supply
system pressures of between 0.3 and 0.5 bar
(typically tank-fed systems between 3m and 5m head).
high sensitivity low pressure valve
The flushing control device shall be suitable for supply
system pressures of between 0.05 and 0.3 bar
(typically tank-fed systems between 0.5m and 3m head).
The above flushing control device shall be as
manufactured by: Cistermiser Limited
Unit 1, Woodley Park Estate, 59 – 69 Reading Road,
Woodley, Reading, RG5 3AN Tel: 0118 969 1611
product codes
standard hydraulic valve: STD
standard hydraulic valve
with hygiene flush: STDIF
low pressure hydraulic valve: LP
low pressure hydraulic valve
with hygiene flush: LPIF
high sensitivity low pressure valve: HSLP
The Cistermiser hydraulic valve consists of three main elements,
as shown left.
Diaphragm operated valve which, when opened, allows
water to pass to the urinal cistern.
Hydraulic accumulator which, if fully charged, will maintain an
equal supply-pressure on both sides of the diaphragm. When
pressure on the inlet side is reduced, as other services are
used, the pressure imbalance causes the valve (1) to open.
Adjuster (restrictor) screw which can be set during installation
to determine the volume of water discharged into the cistern
at each operation by altering the duration of the ‘open’ period.
choosing the right valve
for your application
Three models make up the range of hydraulic valves, each suited
to a different range of water supply pressure. This table will help
to specify the right model for your application.
Colour coded Operating
packaging Model Supply sensitivity
Standard Valve Mains water or 15% of supply
tank-fed systems pressure
...with Hygiene Flush above 5m head
Low Pressure Valve Tank-fed systems, 20% of supply
3m to 5m head pressure
...with Hygiene Flush
High Sensitivity Tank-fed systems, 20% of supply
Low Pressure Valve 0.5m to 3m head pressure
hygiene cycle
In buildings where the washrooms are
vacant for long periods, a hygiene cycle
attachment is available to ensure a
regular flush every 12 hours to prevent
washroom odours.
The bypass screw should be set to permit
a slow drip into the cistern to initiate a flush
approximately every 12 hours. For correct
operation it is essential that the siphon of
the auto flushing cistern does not leak.
1
2
3
1
2
3
urinal flushing
Note: The user can control the amount of water allowed to pass through the valve each
time it is activated; most users choose a range between 0.5 and 10 litres per flush.
35
OURPRODUCTS
• Ensures compliance with the Water Regulations
• Can be concealed to reduce the risk of vandalism
• Mains or battery powered options in the same box:
no external transformer required
• Pipe, wall or ceiling mounted sensor: surface
mounted or recessed
• On DEFRA’s Water Technology List; purchase and
installation are tax deductible
reduces water consumption
by up to 80%
irc valve
cistern-flushing urinal valve with
motion-sensing infrared
The infrared urinal flush control (IRC) valve
automatically manages the supply of water
to a urinal cistern. The PIR sensor detects
movement and activates the solenoid valve,
allowing water into a urinal cistern.
how it works
The infrared urinal flush control (IRC) consists of a solenoid valve
and the sensor module.
When the IRC detects movement in the washroom, a pulse
from the sensor opens the normally-closed solenoid valve and
water flows to the cistern; at the same time the sensor is
switched off.
After 25 minutes the power is restored to the sensor and, as
long as no movement is detected for 5 minutes, the solenoid
valve closes, shutting off the water supply to the cistern.
product information
• The solenoid assembly is plumbed
in on the water supply to the urinal
cistern. The connection to the
infrared sensor is made either by
directly mounting the sensor
module on to the solenoid or by
using the ‘floating socket’ supplied
for a remote mounting. If mounted
remotely, the sensor module
may be:
– Surface mounted using a
standard pattress box.
– Recessed into a suspended
ceiling using the ‘ceiling
mounting kit’ (CMK), supplied
with the IRC as standard.
• If the sensor detects no occupancy
in 12 hours it will automatically
open the valve for 30 minutes to
allow one flush of the cistern to
rinse the urinals and pipework.
• The sequence is designed to
maximise battery life, giving
approximately 3 years’ life from
one good quality set of batteries.
• The flow rate of the water into the
cistern is adjustable to maximise
water economy. Generally this
should be set so that the cistern
flushes once every time the valve
is opened. i.e. every 30 minutes
during occupation.
• The solenoid is supplied with an
interchangeable valve seat which
is used to increase the flow to the
cistern on low pressure supplies.
36
irc valve (ceiling mount kit)
reducing water wastage
and costs
Urinals often flush regardless of use, wasting a
lot of water, especially out of hours. Installing
a Cistermiser IRC valve can save on average
129,600 litres of water per year and reduce
costs by up to £313 per urinal bowl.
specification wording
• The mechanical contractor shall supply and install a
urinal flushing device of the ‘Cistermiser IRC’ type on
the supply pipe to the urinal cistern, as shown on
the drawing.
• The flushing control device shall consist of a PIR
sensor with a control unit and a solenoid valve with
integral flow regulator and interchangeable valve seat.
• The flushing control device should have a hygiene
flush function for periods of low use.
• The flushing control device shall be suitable for supply
system pressures of between 0.1 and 6.0 bar.
• The flushing control device shall be suitable for
connection to either 230V, 50 Hz single phase supply
or 4 x 1.5V alkaline batteries of type LR6.
• The flushing control device shall have provision to be
mounted directly on the pipework or remotely using
either the flush mounting kit supplied or a standard
electrical pattress box.
The above flushing device shall be as
manufactured by: Cistermiser Limited
Unit 1, Woodley Park Estate, 59 – 69 Reading Road,
Woodley, Reading, RG5 3AN Tel: 0118 969 1611
product code
infrared urinal flush control valve: IRC2
installation options
PIR sensor unit
Contained within a white moulded ABS case designed to
fit directly on to the solenoid valve assembly or a
standard 3.25” x 3.25” (83mm x 83mm) pattress box for
surface mounting. At the back there is access to the
battery compartment or terminals for a 240V mains
power supply to the integral and in-built transformer and
the 6V DC output to the solenoid.
dimensions 85 x 85 x 63.5mm (W x H x D) including the
sensor lens
range approx 3.5m field of view, 138˚ horizontal,
125˚ vertical
solenoid voltage 6V DC nominal 54µA, peak 750mA, for 50ms
mains supply 220V – 240V 50hz 20mA
battery supply 4 x 1.5V Alkaline Type LR6
– Cap. 2700mAh
solenoid valve 6V latching valve, UK WRAS approved. One
valve per sensor.
water supply 0.1-6 bar (For 6 bar a pressure reducing
pressure valve is required). Integral, adjustable flow
regulator and interchangeable valve seat.
on the pipe sensor installationremote sensor installation
valve insert pressure max flow min flow
orifice insert litres per min litres per min
1.5mm 6 bar 2.7 0.03
1.5mm 2 bar 1.6 0.01
3.0mm 2 bar 3.0 0.05
3.0mm 0.1 bar 0.9 no flow
NB 3.0mm orifice should only be fitted when fed from a tank below 5m head.
urinal flushing
Uncontrolled urinal IRC
Litres per flush 4.5 4.5
Flushes per hour 4 2
Hours per day 24 12
Days per year 365 260
Water usage per year (ltrs) 157,680 28,080
Water saving per year (ltrs) – 129,600
Water usage per year (m3
) 157.68 28.08
Water costs per m3
(£) 2.42 2.42
Annual water cost (£) 381.56 67.95
Annual water cost saving (£) – 313.61
37
OURPRODUCTS
• Programmable (adjustable) flow duration
• Ligature-resistant touch button
• Low voltage operation from power supply with
battery back-up
• Robust piezo touch button
• 12-hour hygiene rinse option
• Anti-flood feature
• Master control remote disable function
• BREEAM WAT1 compatible product
vandal-resistant touch controlled water
delivery to washroom urinals
av urinal
touch activated washroom water
control with no moving parts
Our av urinal flush control valve, part of the
Cistermiser av range, is a specialist vandal-
resistant, touch-activated washroom control
for use in high risk or demanding public
environments such as prisons, secure
hospitals, schools and sports facilities.
product information
• The touch buttons are made from
robust AISI 316L stainless steel.
They come with anti-rotation
washers and pins to ensure they
cannot be removed or tampered
with and used for self-harm or to
inflict harm on others.
• The highly versatile av range
includes a piezo touch button,
three styles of shower head, two
styles of wall mounted basin spout,
a WC cistern combined flushing
and filling (drop and inlet) valve, a
direct flushing urinal valve, a six
channel controller and a
power supply unit.
• The touch buttons are available in
a choice of three tail lengths to
accommodate panel/wall
thicknesses from 17mm to
330mm. The piezo touch button is
supplied with 3 metres of cable to
allow maximum flexibility for sitting
of the valves and control box.
• System users only have access to
the touch buttons. All other system
components such as solenoid
valves, six channel controllers and
water supply pipes are located in
services voids, which are
inaccessible to the users.
how it works
The user interface is a stainless steel encased piezo touch button which
is fixed flush with the mounting surface. When touched, the button
causes an electronically operated valve to open and allow water to
flush urinals.
The flow duration for each outlet is programmed on installation. If the user
touches the button for a second time, within the programmed flow
period, water flow is stopped at once.
There are no moving parts within the piezo touch button. The buttons are
hard-wired to the AV six channel controller, which controls the outlets.
Each unit can control up to six valves and each piezo touch button
controls one outlet.
38
• Designed for urinals flushing directly from the cold
water supply
• No cistern required
• Only flushes urinal bowl after use
• Vandal-resistant – valve totally concealed
• Hygiene flush for periods of non-use
• Adjustable flush duration and range
• Discreet and Accessible fitment options
• Mains and battery powered options included
• Ensures compliance with Water Regulations
• BREEAM WAT1 compatible product
• On DEFRA’s ECA Water Technology List;
purchase and installation are tax deductible
the cost effective solution
to maximise urinal hygiene
and water economy
direct flush
mains-flushing urinal valve with
infrared activation
39
direct flush accessible
direct flush discreet
OURPRODUCTS
direct flush is an infrared sensor
controlled urinal valve.
The direct flush automatically flushes the
individual urinal after use, ensuring the
highest level of hygiene from the minimum
volume of water. direct flush removes the
need for the auto-flush cistern and
associated plumbing used in traditional
urinal installations, which flush all urinals
intermittently even if they have not all
been used.
product information
• direct flush includes an integral DC
pipe interrupter (air gap), enabling
the installer to connect it directly
to the mains water supply. This
provides fluid category 5 back-
siphonage protection, without the
need for any additional backflow
prevention or check valves.
• direct flush can be powered by
either mains electricity via the DC
transformer or batteries; both
options are included as standard.
When batteries are fitted the
direct flush provides a low battery
warning indicator.
• A mains power supply unit (PSUC)
which powers up to 20 direct flush
urinal valves is also available.
Only 1 fused spur is required
when using this product.
• Additional customised washroom
settings are obtainable via a hand
held remote control Infrared
Configuration Unit (ICU) which is
available as an optional extra. The
remote controller enables rapid
automatic range configuration to the
specific washroom dimensions,
deactivation of the hygiene flush
function and, where a siphonic trap
has been fitted, activation of the
trap refill function.
how it works
The direct flush infrared sensor detects the user at the urinal
bowl and flushes 2 seconds after the user departs. The LED
flashes green every 3 seconds whilst a user is detected.
If a user is detected whilst the water is flushing, the flush is
automatically arrested to prevent splashing and wastage.
During the flush, the LED flashes green once a second.
The flush duration is adjustable which ensures that only the
minimum amount of water necessary is used.
If there has been no use of the urinal for 12 hours, the
direct flush automatically runs a hygiene flush to prevent
odours and the build up of uric acid in the pipework.
urinal flushing40
reducing water
wastage and costs,
ensuring hygiene
Uncontrolled urinals may flush constantly
regardless of use, wasting thousands of
litres of water per year and costing
hundreds of pounds per year.
The direct flush is activated after every
use of the urinal but only flushes 0.5 litres
at a time. Cistermiser has calculated
savings of 134,000 litres and up to
£325 per year where a direct flush has
been installed.
Uncontrolled Direct Flush Direct Flush
Urinal 7.5 ltrs 10 ltrs
per hour per hour
Litres per flush 4.5 0.5 0.5
Flushes per hour 4 15 20
Hours per day 24 12 12
Days per year 365 260 260
Water usage per year (ltrs) 157,680 23,400 31,200
Water saving per year (ltrs) 0 134,280 126,480
Water costs per m³ (£) 2.42 2.42 2.42
Annual water cost (£) 381.58 56.62 75.50
Annual water cost saving (£) 0 324.96 306.08
Water Efficiency Rating DF None
very water efficient
not water efficient
0-30
30-60
60-80
80-120
120-160
23
158
Note: in 1,000s of litres
41
OURPRODUCTS
installation options
direct flush accessible infrared sensor
The direct flush accessible incorporates the valve and the
power options as well as the sensor in a single compact
box housing. It can be installed on to either a concealed
structural wall / frame or on to the exposed wall panel. It is
ideal where access cannot be gained to the wall cavity.
The sensor plate can be removed to enable servicing of
the valve or battery replacement (if battery powered) in the
installed position without the need to remove the panel.
direct flush discreet infrared sensor
The direct flush discreet unit is an alternative installation
option where rear access can be gained to the wall
cavity for servicing and inspection. The valve is mounted
on to the pipework behind the panel or wall together
with either the mains supply unit or batteries, while the
unobtrusive infrared sensor is installed directly above
the urinal bowl.
specification wording
direct flush discreet
The mechanical contractor shall supply and install a
urinal flushing device of the Cistermiser DFD type for
concealed installation where service access is provided
externally. A Cistermiser DFD is to be fitted to each
individual urinal.
The flushing control device is to consist of a PIR sensor
remotely mounted above the urinal and controlling a
solenoid valve with an integral DC pipe interrupter to
comply with Water Regulations.
direct flush accessible
The mechanical contractor shall supply and install a
urinal flushing device of the Cistermiser DFA type for
installation where service access is not provided. A
Cistermiser DFA is to be fitted to each individual urinal.
The flushing control device is to consist of a PIR sensor
controlling a solenoid valve with an integral DC pipe
interrupter to comply with water regulations. The sensor,
valve and integral power supply are to be contained within a
mounting unit with removable face plate to allow service
access once installed. The unit is to be mounted above the
urinal so that the removable face plate is flush with the
finished wall surface.
direct flush discreet  direct flush accessible
The flushing control device is to be fully configurable for
flush time and duration, sensing distance, flush arrest
and is to be programmable either manually or by use of
the ICU (remote control) where supplied. The unit should
also have a programmable periodic hygiene flush function
for periods of low use and a cleaner’s function to conserve
water during routine cleaning and maintenance.
The flushing control device is to be suitable for
connection to either 230v 50Hz AC single phase supply
or from 4 x 1.5v alkaline batteries of type LR6. For
multiple product installations the device is to have the
option of being installed with a common power supply
unit (PSUC) capable of powering several units from one
230v fused spur.
The unit should be the Cistermiser direct flush as
manufactured by: Cistermiser Limited
Unit 1, Woodley Park Estate, 59 – 69 Reading Road,
Woodley, Reading, RG5 3AN Tel: 0118 969 1611
product codes
direct flush discreet: DFD
direct flush accessible: DFA
urinal flushing42
wc flushing 43
wc flushing
easyflush (wave  walkaway)
easyflush direct av wc flushing
0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk
OURPRODUCTS
• Infrared sensor operated WC cistern flush valve
• Defaults to part flush of as low as 2 litres for
maximum water savings
• No-touch means no cross-contamination; hygienic
• Installer programmable flush volumes; improved
water economy
• Flush (outlet) and delayed action fill (inlet) valves
combined in one unit
• Available in active (‘wave’) or passive
(‘walkaway’) mode
hands-free and
water-conserving WC
cistern flush and fill valve
easyflush
wc cistern flush valve
44
easyflush is suitable for concealed or
exposed cisterns.
easyflush is easy to install in retrofits or new
installations. It can also be supplied complete
with its own cistern.
The easyflush no-touch dual flush WC cistern valve
promotes best practice in water economy and
hygiene in domestic and commercial washrooms.
product information
• Both the wave and walkaway
sensors meet the DDA requirements
and are Part M compliant.
• easyflush is two interlinked valves in
one: a lift/drop valve which empties
the cistern and a delayed action
float valve which controls refilling.
• It also includes an integral overflow
pipe to prevent flooding.
• The compact single-piece unit is
located over the outlet by a
bayonet-type locking device which
simplifies installation.
Intelligent memory feature
If the user requires an additional flush
they can bring their hand close to the
infrared sensor to activate a further
flush which will be stored in the
memory and activate after the
programmable cistern refill time
has elapsed.
how it works
easyflush wave is operated by the user bringing their hand close
to an infrared sensor. The dual flush mode enables the user to
select either a part or full flush by the length of time their hand is
in front of the sensor.
For a part flush the hand is held in front of the sensor for up to
one second and, for a full flush, over one second.
easyflush walkaway is normally activated by the user standing
up or leaving the cubicle; however, it can also be activated by
the user bringing their hand toward the sensor.
The walkaway version comes with the dual flush factory
programmed. A part flush will be delivered if the user departs
from the cubicle within 40 seconds and a full flush will be
delivered if the user departs after 40 seconds.
wc flushing 45
OURPRODUCTS
reducing water wastage
through delayed action
UK toilets needlessly flush away 1.2 billion litres of
water a day (Waterwise).
The graph below (adapted from WRc data) shows that
the actual flush volume for a nominal 6 litre WC
increases as pressure increases. The Cistermiser
easyflush will maintain the nominal volume at all
pressures due to its patented delayed action operation.
Installing a Cistermiser easyflush can save up to
162,000 litres per year as shown below.
delayed action valve
operating sequence
The inlet float valve operates with a delayed
action, which only allows the cistern to begin
refilling after it has been completely emptied and
the outlet valve has closed. This patented feature
prevents an increase in the volume of water per
flush. In other systems water can enter the cistern
before the outlet valve has closed, thus increasing
the volume of water per flush.
Plunger
Float
Outlet
Drop Valve
Inlet
Float Valve
Water
Supply
Feed
DISCHARGE
1
3
2
flush triggered
Water pressure lifts plunger, opening
outlet drop valve and holding inlet
float valve in the closed position.
flush finishes
Outlet drop valve closes,
lowering inlet float valve and
cistern begins filling.
unit in standby mode
Once cistern is full, water holds
the inlet float valve closed.
6 litre WC, standard valve
10
9
8
7
6
5
4
3
pressure, bar
actualflushvolume,litres
0 2 4 6 8 10 12
46
standard wc easyflush
Litres per flush (average) 9 2.8
Flushes per day per person 5 5
Number of persons 20 20
Days per year 260 260
Water usage per year (ltrs) 234,000 72,000
Water saving per year (ltrs) – 162,000
Water usage per year (m³) 234 72
Water costs per m³ (£) 2.42 2.42
Annual water cost (£) 566.28 174.24
Annual water cost saving (£) – 392.04
installation options
• easyflush is powered by 4 x 1.5V AA (LR6)
batteries or a 6V DC mains adaptor which can be
installed behind service panels.
• The battery option allows the easyflush to be
installed inside exposed cisterns.
• Also available as an optional extra is a multi
product mains power supply unit (PSUC) to
power up to 20 sensors from a single fused spur.
• The easyflush wave can be fitted into a concealed or
an exposed cistern and can also be easily retrofitted.
• The easyflush walkaway is only suited to
concealed installations.
228mm
283mm37mm
48mm
27mm
93mm84mm 212mm
Ø44mm or Ø50mm
please specify
flush pipe size
easyflush wave
exposed installation
easyflush walkaway
concealed installation
Top
WC WC
Front
Concealed
installation
300 – 400mm
700–900mm
Side
Exposed
installation
wc flushing
cistermiser
concealed
cistern –
easy to fit
The cistern is supplied with the easyflush valve
already installed inside it. The installer only needs to
connect to the water supply and pan. To install and
commission there are three easy steps:
1 Mount the cistern directly on the wall/panel.
2 Mount the sensor through the panel or wall and
fit the power source.
3 Connect the water supply and sensor leads.
Access to the valve after installation is simple and
obtained by removing the lid of the cistern.
• Suitable for the majority of 6 litre WCs .
• Available with either 38mm (1.5”) or 50mm (2”)
diameter flush pipes.
• Side entry water inlet supplied as standard but
bottom entry also available.
• Internal overflow included.
cistern maximum
overall dimensions
(All dimensions with lid fitted)
height: 335mm, width: 510mm, depth 150mm
outlet options: 38mm (1.5”) or 50mm (2”) flush pipe
47
specification wording
easyflush wc cistern flush valve
The mechanical contractor shall supply and install a
no-touch dual flush, sensor operated flush and fill delayed
action valve to each WC cistern.
The valve shall consist of a single remote sensor, solenoid
operated flush valve and combined integral fill valve. The
inlet will include a double check valve. The unit will be of a
dual flush capability from one sensor and the flush volume
will be adjustable both for part and full flush functions. The
sensor will be programmable for operating range, part flush
time, cistern refill time and part flush operation (default is for
part flush to be active). The unit should also incorporate a
cleaner’s function to minimise water usage during routine
cleaning operations. The programming can be carried out
manually by hand or by means of the optional ICU (remote
control). The flush valve and inlet valve are to be linked
(delayed action between inlet and outlet) to ensure that no
water can enter the cistern during the flush cycle to prevent
excess water usage. Compliance with BREEAM WAT1.
The unit should have a periodic hygiene flush function to
ensure facilities are kept in a clean and hygienic condition.
The flush and fill valve is to be suitable for connection to
either 230V 50Hz AC single phase supply or from 4 x 1.5V
alkaline batteries of type LR6. For multiple product
installations the device is to have the option of being
installed with a common power supply unit (PSUC) capable
of powering several units from one 230V fused spur.
The unit is to be suitable for mounting in a variety of
cisterns and is to be easily installed and removed for
maintenance purposes via a bayonet locking device.
The WC cistern flushing valves should be the
easyflush wave or walkaway no-touch dual flush
WC valve as manufactured by: Cistermiser Limited
Unit 1, Woodley Park Estate, 59 – 69 Reading Road,
Woodley, Reading, RG5 3AN Tel: 0118 969 1611
product codes
easyflush wave: EF
easyflush walkaway: EF/Walk
easyflush wave with cistern: EF/CIST
easyflush walkaway with cistern: EF/Walk/CIST
OURPRODUCTS
• No cistern required – save space
• No inlet valves – reduced installation cost
• No cistern refill – immediate re-flush for busy areas
• Infrared sensor operated
• Hygiene flush to maintain cleanliness
• Range of flow rates
• Compliant with Water Regulations. WRAS approved.
infrared sensor activated
mains flushing for WCs
easyflush
direct
48
easyflush direct is an electronic flushing
system for WCs that removes the need for a
WC cistern, by taking its water feed straight
from the mains supply.
This means there is no cistern to be refilled and a
second flush can be activated without a delay.
A hygiene flush can also be activated to maintain
the cleanliness of the WC.
effective flushing
To achieve an effective and efficient flush the water system
needs to deliver at least 90 lpm (litres per minute). Typically this
would require that the dynamic water pressure, measured
before the valve, is at least 2bar. If 90 lpm cannot be achieved,
the flush will be less effective and a longer flush duration or
multiple flushes may be required. This can result in water
wastage.
If the water flow rate exceeds 150 lpm, splashing from the WC
bowl may occur. easyflush direct is fitted with a flow regulator
that will limit the flow rate to 100 lpm. However, additional flow
regulators for 90 lpm and 125 lpm are included, to regulate the
flow rate further, if required.
These flow regulators are coloured coded:
• Dark blue: 90 lpm
• Black: 100 lpm (fitted as standard)
• White: 125 lpm
NOTE: Some WC bowls are designed for low volume flushing and an effective flush can be achieved at low
flow rates. Please check with the WC bowl manufacturer. The flow regulator can be removed to maximize
flush performance but this can lead to excessive water use.
wc flushing 49
product description
• easyflush direct includes a valve,
DC pipe interruptor and sensor.
When the sensor is activated, the
valve is activated for between 2
and 3.5 seconds, supplying water
to flush the WC direct from the
mains water supply. After this
period the valve closes and the
flush is complete, but can be
activated again immediately.
• There are two versions to suit
different applications:
easyflush direct wave
is operated by the user bringing
their hand towards the infrared
sensor. A part flush is triggered by
holding one’s hand in place near
the sensor for about 1 second and
a full flush is triggered by a slightly
longer hand pass.
easyflush direct walkaway
is activated when the user stands
up or leaves the cubicle but it can
also be activated by the user
bringing their hand toward the
sensor. A part flush is triggered by
short user occupancy and a full
flush by long user occupancy (over
45 seconds).
OURPRODUCTS
The graph below shows the approximate flow rates at
a range of dynamic pressures.
Flowrate(litres/min)
Supply pressure (bar)
90 lpm
140
2 3 4
160
180
200
120
100
80
60
40
5 61
0
20
0
100 lpm
125 lpm
No flow regulator
No flow regulator
125 lpm
100 lpm
90 lpm
The flush volume is determined by the flush duration
and the flow rate of the water supply. Using the flow
regulators and adjusting the flush duration, will allow
you to configure the flush performance. However, this
will differ based on the WC bowl design.
The flow rate can also be reduced by turning the
adjuster screw in the middle of the valve (clockwise to
reduce flow) or by fitting a third party pressure reducing
valve above easyflush direct.
Ensure that the dynamic water pressure (pressure
measured while the valve is open and water is flowing)
is sufficient to achieve the required flow rate.
50
installation options
• easyflush direct is powered by a 6V DC mains
adaptor which can be installed behind service
panels.
Also available as an optional extra is a multi-product
mains power supply unit (PSUC) to power up to 20
sensors from a single fused spur.
wc flushing
DC pipe interrupters
easyflush direct introduces an air gap into the water
system. Care must be taken that pipework design and
WC bowl selection is appropriate to ensure sufficient
flow to flush the WC while preventing water flowing
out of the air gap. This can occur when back pressure
is high, caused by a restrictive connection to the WC.
The valve should always be installed as high as
possible on the vertical pipe feeding the WC bowl
flush inlet to prevent water backing up and leaking
from the DC pipe interrupter. When installing the valve
it is good practice to ensure there is an accessible
isolation valve upstream of the valve. Ensure flow rate
at valve does not exceed the flow rate to the WC
bowl, to prevent water backing-up to the DC pipe
interrupter.
easyflush direct is supplied with a DC pipe interrupter
and a 1.5” flush pipe fitting.
Fit the DC pipe interrupter to the valve outlet ensuring
the rubber seal is in place.
If the DC pipe interrupter is not required, fit the 1.5
flush pipe fitting to the pipe outlet in place of the DC
pipe interrupter. Fittings are supplied to connect to a
38mm (1.5”) flush pipe.
NOTE: Ensure the DC pipe interrupter is fitted a min of 300mm above the spill
over point of the WC bowl.
51
specification wording
easyflush direct flush valve
The mechanical contractor shall supply and install a no-
touch dual flush, sensor operated flush.
The unit will be of a dual flush capability from one sensor
and the flush volume will be adjustable both for part and
full flush functions.
The sensor will be programmable for operating range,
part flush and full flush operation (default is for part flush
to be active).
The unit should also incorporate a cleaner’s function to
minimize water usage during routine cleaning operations.
The programming can be carried out manually by hand or
by means of the Infrared Control Unit (not supplied).
The unit should have a periodic hygiene flush function to
ensure facilities are kept in a clean and hygienic condition.
For multiple product installations the device is to have the
option of being installed with a common power supply
unit PSUC capable of powering several units from one
230V fused spur.
The WC flushing valves should be the easyflush direct
wave or walkaway no touch mains flushing WC valve as
manufactured by: Cistermiser Limited
Unit 1, Woodley Park Estate, 59 – 69 Reading Road,
Woodley, Reading, RG5 3AN Tel: 0118 969 1611
product codes
easyflush direct wave: EFD
easyflush direct walkaway: EFD/Walk
67mm
48mm 27mm
126mm
163mm
37mm
OURPRODUCTS
av wc flushing
Our av wc cistern flush control valve, part of
the Cistermiser av range, is a specialist
vandal-resistant, touch-activated washroom
control for use in high risk or demanding
public environments such as prisons, secure
hospitals, schools and sports facilities.
product information
• The touch buttons are made from
robust AISI 316L stainless steel.
They come with anti-rotation
washers and pins to ensure they
cannot be removed or tampered
with and used for self-harm or to
inflict harm on others.
• The highly versatile av range
includes a piezo touch button, three
styles of shower head, two styles of
wall mounted basin spout, a WC
cistern combined flushing and filling
(drop and inlet) valve, a direct
flushing urinal valve, a six channel
controller and a power supply unit.
• The touch buttons are available in a
choice of three tail lengths to
accommodate panel/wall
thicknesses from 17mm to 330mm.
The piezo touch button is supplied
with 3 metres of cable to allow
maximum flexibility for sitting of the
valves and control box.
• System users only have access to
touch buttons and WC bowls.
All other system components such
as solenoid valves, six channel
controllers, WC cisterns and water
supply pipes are located in services
voids, which are inaccessible to
the users.
how it works
The user interface is a stainless steel encased piezo touch button
which is fixed flush with the mounting surface. When touched, the
button causes an electronically operated valve to open and allow
water to flush your WC cistern.
The flow duration for each outlet is programmed on installation. If the
user touches the button for a second time within the programmed
flow period, water flow is stopped at once.
There are no moving parts within the piezo touch button. The
buttons are hard-wired to the AV six channel controller, which
controls the outlets.
Each unit can control up to six valves and each piezo touch button
controls one outlet.
52
• Programmable (adjustable) flow duration
• Ligature-resistant touch button
• Low voltage operation from power supply with
battery back-up
• Robust piezo touch button
• 12-hour hygiene rinse option
• Anti-flood feature
• Master control remote disable function
• BREEAM WAT 1 compatible product
taps and showers 53
taps and showers
novatap vectatap anti-vandal taps
novaspout vectaspout anti-vandal showers
0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk
OURPRODUCTS
• Hands-free infrared basin spouts
• Automatic shut-off: no drips or taps left running
• Improve water and energy efficiency
• Easy to use: ideal for less-abled or elderly
• Hygienic: reduce risk of cross-contamination
• Available in 5 litres per minute and 3.5 litres
per minute models
• Mains and battery powered options included
• Vandal resistant
• Easy to fit in new installations or retrofits
save water, promote
hygiene and reduce
maintenance costs
infrared taps
novatap, novaspout, vectatap
and vectaspout
54
how it works
The flow of water from the spouts is turned on when the
user presents their hands to the infrared sensor which is
located on the lower body of the novatap and vectatap or
is positioned below the novaspout and vectaspout. No
contact is required. When the user’s hands are moved
away the flow of water stops after a 2 second delay.
The novatap and vectatap are
contemporary deck-mounted
chrome basin spouts with an
infrared sensor, control unit and
valve integral in its body,
making it extremely simple
to install.
The novaspout and vectaspout
are elegant panel-mounted
polished stainless steel basin
spouts supplied with an infrared
sensor control unit and valve.
The Water Regulations require that the flow rate of a spout does not exceed
3.6 litres per minute where basins have no plug. The 3.5 litres per minute
model therefore ensures that this spout is compliant in such applications.
product information
• Robust design and build quality
make the spouts ideal for hard use
environments where the less-abled
or elderly may find it difficult to
operate conventional spouts.
• The spouts are particularly useful
where hygiene issues coupled with
water and energy efficiency are
paramount.
• Both the water flow run-on time and
the sensor range between the spout
and the user’s hands are fully
adjustable.
• The spouts automatically switch off
after 60 seconds of continuous flow,
preventing any water wastage if
there is attempted vandalism.
• To prevent the potential build up of
stagnant water, which can create
legionella bacteria growth, the spout
incorporates a hygiene rinse option
which operates 12 hours after the
last use of the spout.
• Additional spout lengths are
available. Please contact Cistermiser
directly for further information.
infrared taps and spouts 55
novatap vectatap (due summer 2013)
novaspout vectaspout
OURPRODUCTS
56
Tap option Wet hands Soap Hands Rinse Total Total Example Water
(5 secs) (10 secs) (20 secs) seconds litres consumption Savings
per year per year
Conventional one handed
lever mixer
35 7.58 415,005 –
Self-closing non-concussive
tap 7ltr/min
30 3.75 205,313 50.5%
Novatap 5 ltr/min flow 25 2.08 113,880 72.6%
Novatap 3.5 ltr/min flow 25 1.46 79,844 80.8%
reducing water wastage
On average, basin spouts deliver 8 litres of water
per minute (BMA). Installing Cistermiser 3.5 litre per
minute spouts can save up to 6 litres per use, saving
over 80% during a 12 month period.
installing a novatap,
novaspout and vectaspout
specification wording
novatap, novaspout, vectatap and vectaspout
– 5 and 3.5 litres per minute
The mechanical contractor shall supply and install
hands free, infrared activated deck-mounted (novatap,
vectatap) or panel-mounted (novaspout) to all wash hand
basin outlets. The units shall be for single water supply;
either cold or temperature controlled hot water and will
incorporate a pressure compensated flow regulator.
The unit will be programmable for sensing range and
run-on duration. The unit will also have a periodic hygiene
rinse function to minimize bacterial infection such as legionella
and have a cleaner’s function for routine janitorial servicing.
The touch free basin spout is to be suitable for connection
to either 230V 50Hz AC single phase supply or from
4 x 1.5V alkaline batteries of type LR6. For multiple product
installations the device is to have the option of being
installed with a common power supply unit PSUC capable
of powering several units from one 230V fused spur.
novatap, vectatap, novaspout and vectaspout
– 5 litres per minute A flow of 5 litres per minute for
compliance with BREEAM WAT1.
novatap, vectatap, novaspout and vectaspout
– 3.5 litres per minute (BREEAM Healthcare
WAT4 compliant) A flow of 3.5 litres per minute for
compliance with BREEAM WAT4 for use with open
waste basins in healthcare applications.
The unit should be the novatap, vectatap, novaspout
or vectaspout as manufactured by: Cistermiser Limited
Unit 1, Woodley Park Estate, 59 – 69 Reading Road,
Woodley, Reading, RG5 3AN Tel: 0118 969 1611
product codes
novatap 5 litres per minute: NT
novatap 3.5 litres per minute: NT/3.5L
novaspout 5 litres per minute: NS/L5
vectaspout 5 litres per minute: VS/L5
vectatap - due summer 2013 - contact us for details
technical information
3.5 litres per minute
The Water Regulations require that the flow rate of a tap
does not exceed 3.6 litres per minute where basins have
no plug. The Cistermiser spouts, with a 3.5 litres per
minute limit ensures compliance in such applications.
This model of flow restrictor is non-aerated and thus
suitable for high risk applications such as medical
facilities and care homes where the risk to users of
legionella and other water-carried respiratory
contracted viruses/bacteria is high.
aerators /nozzles
novatap and novaspout 5 litres per minute are supplied
with a high tech Neoperl®
Caché´®
Perlator®
Honeycomb aerator as standard.
novatap and novaspout 3.5 litres per minute are
supplied with a Neoperl®
Caché´®
Perlator®
Honeycomb laminar nozzle.
• Spray aerators are particularly suitable for low flow
conditions and reducing water consumption in
public areas.
• Non-aerated non-splashing laminar stream.
• Pressure compensating flow limited to 3.5 litres
per minute.
• External battery pack or transformer mounted
below deck.
• Unique single piece
outlet design inhibits
limescale build-up.
• Integral anti-clogging
dome screen filters
sediment  particles.
• Patented design provides
well aerated, soft to touch
splash-free stream.
• Pressure compensating
flow limited to 5 litres
per minute.
140mm
80mm
Basin spout length 209mm
45mm204mm
37mm27mm
48mm
48mm
26.5
mm
infrared taps and spouts 57
200mm
15mm
51mm
• The novatap, novaspout and vectaspout can be
powered by either mains or batteries, with both
options included as standard.
• Also available is a multi product power supply unit
(PSUC) which provides power for up to 20 taps
(Only 1 fused spur required).
• Additional customised settings are obtainable via
a hand held remote control Infrared Configuration
Unit (ICU), which is available as an optional extra.
The remote controller enables rapid automatic
configuration to the specific washroom dimensions
and deactivation of the hygiene rinse function.
OURPRODUCTS
anti-vandal taps
 showers
vandal-resistant touch controlled water
delivery to washroom taps and showers
Our anti-vandal taps and showers are part of
the Cistermiser anti-vandal range, a
specialist vandal-resistant, touch-activated
washroom control package for use in high
risk or demanding public environments such
as prisons, secure hospitals, schools and
sports facilities.
how it works
The user interface is a stainless steel encased piezo touch button
which is fixed flush with the mounting surface. When touched, the
button causes an electronically operated valve to open and allow
water to flow from a hand basin spout or shower head.
The flow duration for each outlet is programmed on installation. If the
user touches the button for a second time within the programmed
flow period, water flow is stopped at once.
There are no moving parts within the piezo touch button. The buttons
are hard-wired to the AV six channel controller, which controls the
outlets. Each unit can control up to six valves and each piezo touch
button controls one outlet.
product information
• Touch buttons, basin spouts and
shower heads are made from
robust AISI 316L stainless steel.
They come with anti-rotation
washers and pins to ensure they
cannot be removed or tampered
with and used for self-harm or to
inflict harm on others. There is a
range of specially contoured anti-
ligature versions of the shower and
basin outlets for use in locations
where self-harm is a real concern.
• The highly versatile av range
includes a piezo touch button,
three styles of shower head, two
styles of wall mounted basin spout,
a WC cistern combined flushing
and filling (drop and inlet) valve, a
direct flushing urinal valve, a six
channel controller and a power
supply unit.
• Touch buttons, shower heads and
basin outlets are available in a
choice of three tail lengths to
accommodate panel/wall
thicknesses from 17mm to
330mm. The piezo touch button is
supplied with 3 metres of cable to
allow maximum flexibility for sitting
of the valves and control box.
• System users only have access to
touch buttons, shower heads and
basin spouts. All other system
components such as solenoid
valves, six channel controllers, WC
cisterns and water supply pipes are
located in services voids, which are
inaccessible to the users.
• Programmable (adjustable) flow duration
• AISI 316L stainless steel for maximum vandal protection
• Ligature-resistant outlet heads and touch button
• Low voltage operation from power supply with battery
back-up
• Robust piezo touch button
• 12-hour hygiene rinse option
• Anti-flood feature
• Master control remote disable function
• BREEAM WAT 1 compatible product
58
total washroom
control systems 59
total washroom
control systems
anti-vandal range valve sensazone
0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk
OURPRODUCTS
• Programmable (adjustable) flow duration
• AISI 316L stainless steel for maximum
vandal protection
• Ligature-resistant outlet heads and touch button
• Low voltage operation from power supply with
battery back-up
• Robust piezo touch button
• 12-hour hygiene rinse option
• Anti-flood feature
• Master control remote disable function
vandal-resistant
touch-controlled water
delivery to washrooms
anti-vandal
range valve
touch activated washroom water
control with no moving parts
Cistermiser’s anti-vandal range is a
specialist vandal-resistant range of touch-
activated washroom controls for use in high
risk or demanding public environments
such as prisons, secure hospitals, schools
and sports facilities.
product information
• Touch buttons, basin spouts and
shower heads are made from
robust AISI 316L stainless steel.
They come with anti-rotation
washers and pins to ensure they
cannot be removed or tampered
with and used for self-harm or to
inflict harm on others. There is a
range of specially contoured anti-
ligature versions of the shower and
basin outlets for use in locations
where self-harm is a real concern.
• The highly versatile anti-vandal
range includes a piezo touch
button, three styles of shower
head, two styles of wall mounted
basin spout, a WC cistern
combined flushing and filling (drop
and inlet) valve, a direct flushing
urinal valve, a six channel controller
and a power supply unit.
• Touch buttons, shower heads and
basin outlets are available in a
choice of three tail lengths to
accommodate panel/wall
thicknesses from 17mm to
330mm. The piezo touch button is
supplied with 3 metres of cable to
allow maximum flexibility for sitting
of the valves and control box.
• System users only have access to
touch buttons, shower heads,
basin spouts, urinals and WC
bowls. All other system
components such as solenoid
valves, six channel controllers, WC
cisterns and water supply pipes are
located in services voids, which are
inaccessible to the users.
60
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2013
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2013
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2013
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2013
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2013
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2013
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2013
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2013

More Related Content

What's hot

Clear Aqua Technologies Private Limited, Trichy, Sewage Treatment Plant
Clear Aqua Technologies Private Limited, Trichy, Sewage Treatment PlantClear Aqua Technologies Private Limited, Trichy, Sewage Treatment Plant
Clear Aqua Technologies Private Limited, Trichy, Sewage Treatment PlantIndiaMART InterMESH Limited
 
Kuristuck Technology – Paint booth treatment
Kuristuck Technology – Paint booth treatmentKuristuck Technology – Paint booth treatment
Kuristuck Technology – Paint booth treatmentKurita
 
Heat exchanger-guide
Heat exchanger-guideHeat exchanger-guide
Heat exchanger-guideChevronelle
 
Biodiesel washing
Biodiesel washingBiodiesel washing
Biodiesel washingsrs intl
 
DEGRÉMONT FOOD AND BEVERAGE BROCHURE
 DEGRÉMONT FOOD AND BEVERAGE BROCHURE DEGRÉMONT FOOD AND BEVERAGE BROCHURE
DEGRÉMONT FOOD AND BEVERAGE BROCHURERick Nabett
 
Induction Capsealer
Induction CapsealerInduction Capsealer
Induction CapsealerVivek Chinoy
 
Economy Refrigeration Pvt. Ltd., Thane, Industrial Blower & Pumps
Economy Refrigeration Pvt. Ltd., Thane, Industrial Blower & PumpsEconomy Refrigeration Pvt. Ltd., Thane, Industrial Blower & Pumps
Economy Refrigeration Pvt. Ltd., Thane, Industrial Blower & PumpsIndiaMART InterMESH Limited
 
CWG water treatment book 2016.eng
CWG water treatment book 2016.engCWG water treatment book 2016.eng
CWG water treatment book 2016.engMario Skrapec
 
Food & Beverage industry-Magnetrol
Food & Beverage industry-MagnetrolFood & Beverage industry-Magnetrol
Food & Beverage industry-MagnetrolBenjamin Kyalo
 
DEGRÉMONT PROCESS WATER BROCHURE
DEGRÉMONT PROCESS WATER BROCHUREDEGRÉMONT PROCESS WATER BROCHURE
DEGRÉMONT PROCESS WATER BROCHURERick Nabett
 
IEC Products (Ramandeep)
IEC Products (Ramandeep)IEC Products (Ramandeep)
IEC Products (Ramandeep)Raman Sharma
 
Vaporfection Dealer Presentation 101915
Vaporfection Dealer Presentation 101915Vaporfection Dealer Presentation 101915
Vaporfection Dealer Presentation 101915Herbert Postma
 

What's hot (18)

Dharshan aqua-tech
Dharshan aqua-techDharshan aqua-tech
Dharshan aqua-tech
 
Clear Aqua Technologies Private Limited, Trichy, Sewage Treatment Plant
Clear Aqua Technologies Private Limited, Trichy, Sewage Treatment PlantClear Aqua Technologies Private Limited, Trichy, Sewage Treatment Plant
Clear Aqua Technologies Private Limited, Trichy, Sewage Treatment Plant
 
Kuristuck Technology – Paint booth treatment
Kuristuck Technology – Paint booth treatmentKuristuck Technology – Paint booth treatment
Kuristuck Technology – Paint booth treatment
 
Heat exchanger-guide
Heat exchanger-guideHeat exchanger-guide
Heat exchanger-guide
 
Avni water-technology
Avni water-technologyAvni water-technology
Avni water-technology
 
Biodiesel washing
Biodiesel washingBiodiesel washing
Biodiesel washing
 
DEGRÉMONT FOOD AND BEVERAGE BROCHURE
 DEGRÉMONT FOOD AND BEVERAGE BROCHURE DEGRÉMONT FOOD AND BEVERAGE BROCHURE
DEGRÉMONT FOOD AND BEVERAGE BROCHURE
 
Hindustan engineers
Hindustan engineersHindustan engineers
Hindustan engineers
 
Induction Capsealer
Induction CapsealerInduction Capsealer
Induction Capsealer
 
Economy Refrigeration Pvt. Ltd., Thane, Industrial Blower & Pumps
Economy Refrigeration Pvt. Ltd., Thane, Industrial Blower & PumpsEconomy Refrigeration Pvt. Ltd., Thane, Industrial Blower & Pumps
Economy Refrigeration Pvt. Ltd., Thane, Industrial Blower & Pumps
 
CWG water treatment book 2016.eng
CWG water treatment book 2016.engCWG water treatment book 2016.eng
CWG water treatment book 2016.eng
 
Food & Beverage industry-Magnetrol
Food & Beverage industry-MagnetrolFood & Beverage industry-Magnetrol
Food & Beverage industry-Magnetrol
 
DEGRÉMONT PROCESS WATER BROCHURE
DEGRÉMONT PROCESS WATER BROCHUREDEGRÉMONT PROCESS WATER BROCHURE
DEGRÉMONT PROCESS WATER BROCHURE
 
IEC Products (Ramandeep)
IEC Products (Ramandeep)IEC Products (Ramandeep)
IEC Products (Ramandeep)
 
Vaporfection Dealer Presentation 101915
Vaporfection Dealer Presentation 101915Vaporfection Dealer Presentation 101915
Vaporfection Dealer Presentation 101915
 
CPS Chemical FESPA
CPS Chemical FESPACPS Chemical FESPA
CPS Chemical FESPA
 
LPS minibrochure
LPS minibrochureLPS minibrochure
LPS minibrochure
 
A3S profile
A3S profileA3S profile
A3S profile
 

Viewers also liked

Viewers also liked (7)

Mayfair Taps Catalogue at Taps4Less.com
Mayfair Taps Catalogue at Taps4Less.comMayfair Taps Catalogue at Taps4Less.com
Mayfair Taps Catalogue at Taps4Less.com
 
Niagara Middle East Water Catalog MEWC41013 - Copy
Niagara Middle East Water Catalog MEWC41013 - CopyNiagara Middle East Water Catalog MEWC41013 - Copy
Niagara Middle East Water Catalog MEWC41013 - Copy
 
EcoAeon UAE Arabic Brochure
EcoAeon UAE Arabic BrochureEcoAeon UAE Arabic Brochure
EcoAeon UAE Arabic Brochure
 
Visam Flush Tank Catalogue
Visam Flush Tank CatalogueVisam Flush Tank Catalogue
Visam Flush Tank Catalogue
 
Grohe blue book bath
Grohe blue book bathGrohe blue book bath
Grohe blue book bath
 
Cera sanitaryware
Cera sanitarywareCera sanitaryware
Cera sanitaryware
 
Industrial wastewater treatment
Industrial wastewater treatmentIndustrial wastewater treatment
Industrial wastewater treatment
 

Similar to Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2013

Urimat brochure
Urimat brochureUrimat brochure
Urimat brochurefheimberg
 
Latest Offshore Oil and Gas Innovations by McDermott - GineersNow Engineering...
Latest Offshore Oil and Gas Innovations by McDermott - GineersNow Engineering...Latest Offshore Oil and Gas Innovations by McDermott - GineersNow Engineering...
Latest Offshore Oil and Gas Innovations by McDermott - GineersNow Engineering...GineersNow
 
Smeg laboratory glassware washers
Smeg laboratory glassware washersSmeg laboratory glassware washers
Smeg laboratory glassware washersForrayFerenc
 
Stormsaver Commercial Brochure 2014
Stormsaver Commercial Brochure 2014Stormsaver Commercial Brochure 2014
Stormsaver Commercial Brochure 2014Mike Farnsworth
 
dolphin-modular-system-brochure
dolphin-modular-system-brochuredolphin-modular-system-brochure
dolphin-modular-system-brochureDarren Fooks
 
Coates Hire - Water Treatment Engineering Solutions
Coates Hire - Water Treatment Engineering Solutions Coates Hire - Water Treatment Engineering Solutions
Coates Hire - Water Treatment Engineering Solutions Rafi Tchopourian
 
Aqualisa quartz - Case study (STP)
Aqualisa quartz - Case study (STP)Aqualisa quartz - Case study (STP)
Aqualisa quartz - Case study (STP)Raoul Gauthier
 
Verteco_Water Warrior 12PP Brochure US_UPC_Proof
Verteco_Water Warrior 12PP Brochure US_UPC_ProofVerteco_Water Warrior 12PP Brochure US_UPC_Proof
Verteco_Water Warrior 12PP Brochure US_UPC_ProofBarry Lewis
 
Verantis India Private Limited, Pune, Incinerator System & Wastewater Treatme...
Verantis India Private Limited, Pune, Incinerator System & Wastewater Treatme...Verantis India Private Limited, Pune, Incinerator System & Wastewater Treatme...
Verantis India Private Limited, Pune, Incinerator System & Wastewater Treatme...IndiaMART InterMESH Limited
 
SciencoFAST Marine Sanitation & Water Treatment Project Portfolio Book | www....
SciencoFAST Marine Sanitation & Water Treatment Project Portfolio Book | www....SciencoFAST Marine Sanitation & Water Treatment Project Portfolio Book | www....
SciencoFAST Marine Sanitation & Water Treatment Project Portfolio Book | www....BioMicrobics, Inc.
 
Vado Showering Packages 2019
Vado Showering Packages 2019Vado Showering Packages 2019
Vado Showering Packages 2019Taps4Less.com
 
WATEC ISRAEL 2013, Israeli water companies for Analysing & Measurement
WATEC ISRAEL 2013, Israeli water companies for Analysing & MeasurementWATEC ISRAEL 2013, Israeli water companies for Analysing & Measurement
WATEC ISRAEL 2013, Israeli water companies for Analysing & MeasurementFSJU AUJF
 
Hydrofinity UAE Hospitality Brochure
Hydrofinity UAE Hospitality BrochureHydrofinity UAE Hospitality Brochure
Hydrofinity UAE Hospitality BrochureTonyKerr14
 

Similar to Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2013 (20)

Urimat brochure
Urimat brochureUrimat brochure
Urimat brochure
 
Sanitizing and maintenance products catalogue
Sanitizing and maintenance products catalogueSanitizing and maintenance products catalogue
Sanitizing and maintenance products catalogue
 
Latest Offshore Oil and Gas Innovations by McDermott - GineersNow Engineering...
Latest Offshore Oil and Gas Innovations by McDermott - GineersNow Engineering...Latest Offshore Oil and Gas Innovations by McDermott - GineersNow Engineering...
Latest Offshore Oil and Gas Innovations by McDermott - GineersNow Engineering...
 
Smeg laboratory glassware washers
Smeg laboratory glassware washersSmeg laboratory glassware washers
Smeg laboratory glassware washers
 
Duct brochure 2016
Duct brochure 2016Duct brochure 2016
Duct brochure 2016
 
Stormsaver Commercial Brochure 2014
Stormsaver Commercial Brochure 2014Stormsaver Commercial Brochure 2014
Stormsaver Commercial Brochure 2014
 
dolphin-modular-system-brochure
dolphin-modular-system-brochuredolphin-modular-system-brochure
dolphin-modular-system-brochure
 
Dart Valley Systems Anti Ligature Washroom Controls
Dart Valley Systems Anti Ligature Washroom Controls Dart Valley Systems Anti Ligature Washroom Controls
Dart Valley Systems Anti Ligature Washroom Controls
 
Coates Hire - Water Treatment Engineering Solutions
Coates Hire - Water Treatment Engineering Solutions Coates Hire - Water Treatment Engineering Solutions
Coates Hire - Water Treatment Engineering Solutions
 
Aqualisa quartz - Case study (STP)
Aqualisa quartz - Case study (STP)Aqualisa quartz - Case study (STP)
Aqualisa quartz - Case study (STP)
 
Verteco_Water Warrior 12PP Brochure US_UPC_Proof
Verteco_Water Warrior 12PP Brochure US_UPC_ProofVerteco_Water Warrior 12PP Brochure US_UPC_Proof
Verteco_Water Warrior 12PP Brochure US_UPC_Proof
 
Verantisindia
VerantisindiaVerantisindia
Verantisindia
 
Verantis India Private Limited, Pune, Incinerator System & Wastewater Treatme...
Verantis India Private Limited, Pune, Incinerator System & Wastewater Treatme...Verantis India Private Limited, Pune, Incinerator System & Wastewater Treatme...
Verantis India Private Limited, Pune, Incinerator System & Wastewater Treatme...
 
SciencoFAST Marine Sanitation & Water Treatment Project Portfolio Book | www....
SciencoFAST Marine Sanitation & Water Treatment Project Portfolio Book | www....SciencoFAST Marine Sanitation & Water Treatment Project Portfolio Book | www....
SciencoFAST Marine Sanitation & Water Treatment Project Portfolio Book | www....
 
Share slides
Share slidesShare slides
Share slides
 
HVAC eBook final
HVAC eBook finalHVAC eBook final
HVAC eBook final
 
Vado Showering Packages 2019
Vado Showering Packages 2019Vado Showering Packages 2019
Vado Showering Packages 2019
 
WATEC ISRAEL 2013, Israeli water companies for Analysing & Measurement
WATEC ISRAEL 2013, Israeli water companies for Analysing & MeasurementWATEC ISRAEL 2013, Israeli water companies for Analysing & Measurement
WATEC ISRAEL 2013, Israeli water companies for Analysing & Measurement
 
Hydrofinity UAE Hospitality Brochure
Hydrofinity UAE Hospitality BrochureHydrofinity UAE Hospitality Brochure
Hydrofinity UAE Hospitality Brochure
 
Rain Maintain 2014
Rain Maintain 2014Rain Maintain 2014
Rain Maintain 2014
 

More from Thorne & Derrick UK

Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...Thorne & Derrick UK
 
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...Thorne & Derrick UK
 
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - BrochureWolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - BrochureThorne & Derrick UK
 
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...Thorne & Derrick UK
 
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...Thorne & Derrick UK
 
SIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
SIRAI - Solenoid Valves (WRAS Approved) - Overview CatalogueSIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
SIRAI - Solenoid Valves (WRAS Approved) - Overview CatalogueThorne & Derrick UK
 
Sika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration InstrumentsSika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration InstrumentsThorne & Derrick UK
 
SICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - CatalogueSICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - CatalogueThorne & Derrick UK
 
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...Thorne & Derrick UK
 
Patol Analogue Linear Heat Detection Cable
Patol Analogue Linear Heat Detection CablePatol Analogue Linear Heat Detection Cable
Patol Analogue Linear Heat Detection CableThorne & Derrick UK
 
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...Thorne & Derrick UK
 
MSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
MSA Gas Detectors – Portable & Fixed Gas Detection - BrochureMSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
MSA Gas Detectors – Portable & Fixed Gas Detection - BrochureThorne & Derrick UK
 
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp OnFlow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp OnThorne & Derrick UK
 
LMK Thermosafe Hazardous Area Drum & IBC Product Overview
LMK Thermosafe Hazardous Area Drum & IBC Product OverviewLMK Thermosafe Hazardous Area Drum & IBC Product Overview
LMK Thermosafe Hazardous Area Drum & IBC Product OverviewThorne & Derrick UK
 
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...Thorne & Derrick UK
 
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product BrochureKatronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product BrochureThorne & Derrick UK
 
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...Thorne & Derrick UK
 
Itron - Gas, Water & Heat Meters - Corporate Brochure
Itron - Gas, Water & Heat Meters - Corporate BrochureItron - Gas, Water & Heat Meters - Corporate Brochure
Itron - Gas, Water & Heat Meters - Corporate BrochureThorne & Derrick UK
 
IFM Electronic - Sensors (Flow, Pressure, Level & Temperature Sensors) - Cata...
IFM Electronic - Sensors (Flow, Pressure, Level & Temperature Sensors) - Cata...IFM Electronic - Sensors (Flow, Pressure, Level & Temperature Sensors) - Cata...
IFM Electronic - Sensors (Flow, Pressure, Level & Temperature Sensors) - Cata...Thorne & Derrick UK
 

More from Thorne & Derrick UK (20)

Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
 
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
 
Dart Valley Systems Catalogue
Dart Valley Systems CatalogueDart Valley Systems Catalogue
Dart Valley Systems Catalogue
 
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - BrochureWolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
 
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
 
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
 
SIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
SIRAI - Solenoid Valves (WRAS Approved) - Overview CatalogueSIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
SIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
 
Sika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration InstrumentsSika Measuring Metering Calibration Instruments
Sika Measuring Metering Calibration Instruments
 
SICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - CatalogueSICK - Sensors & Sensor Solutions - Catalogue
SICK - Sensors & Sensor Solutions - Catalogue
 
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
 
Patol Analogue Linear Heat Detection Cable
Patol Analogue Linear Heat Detection CablePatol Analogue Linear Heat Detection Cable
Patol Analogue Linear Heat Detection Cable
 
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
 
MSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
MSA Gas Detectors – Portable & Fixed Gas Detection - BrochureMSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
MSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
 
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp OnFlow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
 
LMK Thermosafe Hazardous Area Drum & IBC Product Overview
LMK Thermosafe Hazardous Area Drum & IBC Product OverviewLMK Thermosafe Hazardous Area Drum & IBC Product Overview
LMK Thermosafe Hazardous Area Drum & IBC Product Overview
 
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
 
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product BrochureKatronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
 
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
 
Itron - Gas, Water & Heat Meters - Corporate Brochure
Itron - Gas, Water & Heat Meters - Corporate BrochureItron - Gas, Water & Heat Meters - Corporate Brochure
Itron - Gas, Water & Heat Meters - Corporate Brochure
 
IFM Electronic - Sensors (Flow, Pressure, Level & Temperature Sensors) - Cata...
IFM Electronic - Sensors (Flow, Pressure, Level & Temperature Sensors) - Cata...IFM Electronic - Sensors (Flow, Pressure, Level & Temperature Sensors) - Cata...
IFM Electronic - Sensors (Flow, Pressure, Level & Temperature Sensors) - Cata...
 

Recently uploaded

How to Build Multifamily and Laneway Suites in Toronto!! (feat. Expert Archi...
How to Build Multifamily and Laneway Suites  in Toronto!! (feat. Expert Archi...How to Build Multifamily and Laneway Suites  in Toronto!! (feat. Expert Archi...
How to Build Multifamily and Laneway Suites in Toronto!! (feat. Expert Archi...Volition Properties
 
Sankla East World Hadapsar Pune E-Brochure.pdf
Sankla East World Hadapsar Pune  E-Brochure.pdfSankla East World Hadapsar Pune  E-Brochure.pdf
Sankla East World Hadapsar Pune E-Brochure.pdfManishSaxena95
 
Rustomjee Cleon Bandra East, Mumbai - Brochure.pdf
Rustomjee Cleon Bandra East, Mumbai - Brochure.pdfRustomjee Cleon Bandra East, Mumbai - Brochure.pdf
Rustomjee Cleon Bandra East, Mumbai - Brochure.pdfmonikasharma630
 
Building Dreams: Newman Leech's Visionary Approach to Real Estate Investment
Building Dreams: Newman Leech's Visionary Approach to Real Estate InvestmentBuilding Dreams: Newman Leech's Visionary Approach to Real Estate Investment
Building Dreams: Newman Leech's Visionary Approach to Real Estate InvestmentNewman George Leech
 
Nanke Area Estate commercial ( Dir. Kat Kuo)
Nanke Area Estate commercial ( Dir. Kat Kuo)Nanke Area Estate commercial ( Dir. Kat Kuo)
Nanke Area Estate commercial ( Dir. Kat Kuo)jessica288382
 
Call Girls in Inderpuri Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Inderpuri Delhi 💯Call Us 🔝8264348440🔝Call Girls in Inderpuri Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Inderpuri Delhi 💯Call Us 🔝8264348440🔝soniya singh
 
Call Girls in Kashmiri Gate Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Kashmiri Gate Delhi 💯Call Us 🔝8264348440🔝Call Girls in Kashmiri Gate Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Kashmiri Gate Delhi 💯Call Us 🔝8264348440🔝soniya singh
 
9990771857 Call Girls in Noida Sector 11 Noida (Call Girls) Delhi
9990771857 Call Girls in Noida Sector 11 Noida (Call Girls) Delhi9990771857 Call Girls in Noida Sector 11 Noida (Call Girls) Delhi
9990771857 Call Girls in Noida Sector 11 Noida (Call Girls) Delhidelhimodel235
 
Telibagh & Call Girls Lucknow - 450+ Call Girl Cash Payment 🎂 8923113531 🎪 Ne...
Telibagh & Call Girls Lucknow - 450+ Call Girl Cash Payment 🎂 8923113531 🎪 Ne...Telibagh & Call Girls Lucknow - 450+ Call Girl Cash Payment 🎂 8923113531 🎪 Ne...
Telibagh & Call Girls Lucknow - 450+ Call Girl Cash Payment 🎂 8923113531 🎪 Ne...gurkirankumar98700
 
9990771857 Call Girls in Noida Sector 1 Noida (Call Girls) Delhi
9990771857 Call Girls in Noida Sector 1 Noida (Call Girls) Delhi9990771857 Call Girls in Noida Sector 1 Noida (Call Girls) Delhi
9990771857 Call Girls in Noida Sector 1 Noida (Call Girls) Delhidelhimodel235
 
Call Girls in Nehru Place Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Nehru Place Delhi 💯Call Us 🔝8264348440🔝Call Girls in Nehru Place Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Nehru Place Delhi 💯Call Us 🔝8264348440🔝soniya singh
 
9990771857 Call Girls in Noida Sector 34 Noida (Call Girls) Delhi
9990771857 Call Girls in Noida Sector 34 Noida (Call Girls) Delhi9990771857 Call Girls in Noida Sector 34 Noida (Call Girls) Delhi
9990771857 Call Girls in Noida Sector 34 Noida (Call Girls) Delhidelhimodel235
 
Low Rate Call Girls in Triveni Complex Delhi Call 9990771857
Low Rate Call Girls in Triveni Complex Delhi Call 9990771857Low Rate Call Girls in Triveni Complex Delhi Call 9990771857
Low Rate Call Girls in Triveni Complex Delhi Call 9990771857delhimodel235
 
Call Girls in Noida Sector 77 Noida 💯Call Us 🔝 9582086666 🔝 South Delhi Escor...
Call Girls in Noida Sector 77 Noida 💯Call Us 🔝 9582086666 🔝 South Delhi Escor...Call Girls in Noida Sector 77 Noida 💯Call Us 🔝 9582086666 🔝 South Delhi Escor...
Call Girls in Noida Sector 77 Noida 💯Call Us 🔝 9582086666 🔝 South Delhi Escor...delhimodel235
 
Model Call Girl in Shastri Nagar Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Shastri Nagar Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Shastri Nagar Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Shastri Nagar Delhi reach out to us at 🔝8264348440🔝soniya singh
 
call girls in ganesh nagar Delhi 8264348440 ✅ call girls ❤️
call girls in ganesh nagar Delhi 8264348440 ✅ call girls ❤️call girls in ganesh nagar Delhi 8264348440 ✅ call girls ❤️
call girls in ganesh nagar Delhi 8264348440 ✅ call girls ❤️soniya singh
 
Call Girls in Janakpuri ↫8447779280↫Short 1500 Night 6000-Escorts Service In ...
Call Girls in Janakpuri ↫8447779280↫Short 1500 Night 6000-Escorts Service In ...Call Girls in Janakpuri ↫8447779280↫Short 1500 Night 6000-Escorts Service In ...
Call Girls in Janakpuri ↫8447779280↫Short 1500 Night 6000-Escorts Service In ...asmaqueen5
 
Purva Palm Hills Devanahalli, Bangalore E- Brochure.pdf
Purva Palm Hills Devanahalli, Bangalore E- Brochure.pdfPurva Palm Hills Devanahalli, Bangalore E- Brochure.pdf
Purva Palm Hills Devanahalli, Bangalore E- Brochure.pdffaheemali990101
 
Omaxe Dwarka In Delhi E Brochure Pdf
Omaxe Dwarka In Delhi E Brochure     PdfOmaxe Dwarka In Delhi E Brochure     Pdf
Omaxe Dwarka In Delhi E Brochure Pdfashiyadav24
 
Shapoorji Pallonji Parkwest Sequoia Tower Bangalore.pdf
Shapoorji Pallonji Parkwest Sequoia Tower Bangalore.pdfShapoorji Pallonji Parkwest Sequoia Tower Bangalore.pdf
Shapoorji Pallonji Parkwest Sequoia Tower Bangalore.pdfashiyadav24
 

Recently uploaded (20)

How to Build Multifamily and Laneway Suites in Toronto!! (feat. Expert Archi...
How to Build Multifamily and Laneway Suites  in Toronto!! (feat. Expert Archi...How to Build Multifamily and Laneway Suites  in Toronto!! (feat. Expert Archi...
How to Build Multifamily and Laneway Suites in Toronto!! (feat. Expert Archi...
 
Sankla East World Hadapsar Pune E-Brochure.pdf
Sankla East World Hadapsar Pune  E-Brochure.pdfSankla East World Hadapsar Pune  E-Brochure.pdf
Sankla East World Hadapsar Pune E-Brochure.pdf
 
Rustomjee Cleon Bandra East, Mumbai - Brochure.pdf
Rustomjee Cleon Bandra East, Mumbai - Brochure.pdfRustomjee Cleon Bandra East, Mumbai - Brochure.pdf
Rustomjee Cleon Bandra East, Mumbai - Brochure.pdf
 
Building Dreams: Newman Leech's Visionary Approach to Real Estate Investment
Building Dreams: Newman Leech's Visionary Approach to Real Estate InvestmentBuilding Dreams: Newman Leech's Visionary Approach to Real Estate Investment
Building Dreams: Newman Leech's Visionary Approach to Real Estate Investment
 
Nanke Area Estate commercial ( Dir. Kat Kuo)
Nanke Area Estate commercial ( Dir. Kat Kuo)Nanke Area Estate commercial ( Dir. Kat Kuo)
Nanke Area Estate commercial ( Dir. Kat Kuo)
 
Call Girls in Inderpuri Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Inderpuri Delhi 💯Call Us 🔝8264348440🔝Call Girls in Inderpuri Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Inderpuri Delhi 💯Call Us 🔝8264348440🔝
 
Call Girls in Kashmiri Gate Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Kashmiri Gate Delhi 💯Call Us 🔝8264348440🔝Call Girls in Kashmiri Gate Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Kashmiri Gate Delhi 💯Call Us 🔝8264348440🔝
 
9990771857 Call Girls in Noida Sector 11 Noida (Call Girls) Delhi
9990771857 Call Girls in Noida Sector 11 Noida (Call Girls) Delhi9990771857 Call Girls in Noida Sector 11 Noida (Call Girls) Delhi
9990771857 Call Girls in Noida Sector 11 Noida (Call Girls) Delhi
 
Telibagh & Call Girls Lucknow - 450+ Call Girl Cash Payment 🎂 8923113531 🎪 Ne...
Telibagh & Call Girls Lucknow - 450+ Call Girl Cash Payment 🎂 8923113531 🎪 Ne...Telibagh & Call Girls Lucknow - 450+ Call Girl Cash Payment 🎂 8923113531 🎪 Ne...
Telibagh & Call Girls Lucknow - 450+ Call Girl Cash Payment 🎂 8923113531 🎪 Ne...
 
9990771857 Call Girls in Noida Sector 1 Noida (Call Girls) Delhi
9990771857 Call Girls in Noida Sector 1 Noida (Call Girls) Delhi9990771857 Call Girls in Noida Sector 1 Noida (Call Girls) Delhi
9990771857 Call Girls in Noida Sector 1 Noida (Call Girls) Delhi
 
Call Girls in Nehru Place Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Nehru Place Delhi 💯Call Us 🔝8264348440🔝Call Girls in Nehru Place Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Nehru Place Delhi 💯Call Us 🔝8264348440🔝
 
9990771857 Call Girls in Noida Sector 34 Noida (Call Girls) Delhi
9990771857 Call Girls in Noida Sector 34 Noida (Call Girls) Delhi9990771857 Call Girls in Noida Sector 34 Noida (Call Girls) Delhi
9990771857 Call Girls in Noida Sector 34 Noida (Call Girls) Delhi
 
Low Rate Call Girls in Triveni Complex Delhi Call 9990771857
Low Rate Call Girls in Triveni Complex Delhi Call 9990771857Low Rate Call Girls in Triveni Complex Delhi Call 9990771857
Low Rate Call Girls in Triveni Complex Delhi Call 9990771857
 
Call Girls in Noida Sector 77 Noida 💯Call Us 🔝 9582086666 🔝 South Delhi Escor...
Call Girls in Noida Sector 77 Noida 💯Call Us 🔝 9582086666 🔝 South Delhi Escor...Call Girls in Noida Sector 77 Noida 💯Call Us 🔝 9582086666 🔝 South Delhi Escor...
Call Girls in Noida Sector 77 Noida 💯Call Us 🔝 9582086666 🔝 South Delhi Escor...
 
Model Call Girl in Shastri Nagar Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Shastri Nagar Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Shastri Nagar Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Shastri Nagar Delhi reach out to us at 🔝8264348440🔝
 
call girls in ganesh nagar Delhi 8264348440 ✅ call girls ❤️
call girls in ganesh nagar Delhi 8264348440 ✅ call girls ❤️call girls in ganesh nagar Delhi 8264348440 ✅ call girls ❤️
call girls in ganesh nagar Delhi 8264348440 ✅ call girls ❤️
 
Call Girls in Janakpuri ↫8447779280↫Short 1500 Night 6000-Escorts Service In ...
Call Girls in Janakpuri ↫8447779280↫Short 1500 Night 6000-Escorts Service In ...Call Girls in Janakpuri ↫8447779280↫Short 1500 Night 6000-Escorts Service In ...
Call Girls in Janakpuri ↫8447779280↫Short 1500 Night 6000-Escorts Service In ...
 
Purva Palm Hills Devanahalli, Bangalore E- Brochure.pdf
Purva Palm Hills Devanahalli, Bangalore E- Brochure.pdfPurva Palm Hills Devanahalli, Bangalore E- Brochure.pdf
Purva Palm Hills Devanahalli, Bangalore E- Brochure.pdf
 
Omaxe Dwarka In Delhi E Brochure Pdf
Omaxe Dwarka In Delhi E Brochure     PdfOmaxe Dwarka In Delhi E Brochure     Pdf
Omaxe Dwarka In Delhi E Brochure Pdf
 
Shapoorji Pallonji Parkwest Sequoia Tower Bangalore.pdf
Shapoorji Pallonji Parkwest Sequoia Tower Bangalore.pdfShapoorji Pallonji Parkwest Sequoia Tower Bangalore.pdf
Shapoorji Pallonji Parkwest Sequoia Tower Bangalore.pdf
 

Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2013

  • 2. Cistermiser has been designing and manufacturing a range of high quality, cost effective, water efficient products for over 30 years. our early days The company developed its first product, a hydraulic urinal flush control valve in 1976 at a time when there were no regulations stipulating that companies had to minimise water consumption in the washroom. The desire to conserve water and promote washroom hygiene is the key driver of Cistermiser’s ongoing investment in new product development. research and development Two low pressure derivatives of the hydraulic valve were developed during the 1980s before the company added its first domestic product, a limescale prevention device called Combimate, to its range in 1987. Investment in R&D led to the development of electronic technologies and the company launched a complete washroom control and the infrared urinal flush control valve in the early 1990s. In recent years, the company’s product portfolio has expanded into all areas of the washroom with the addition of a WC flushing device, a mains-flushing urinal control, a complete anti-vandal range and a series of infrared taps and spouts. cistermiser today Today the Cistermiser name is synonymous with quality and reliability and has become a generic term for all urinal flush controls. We now offer solutions for commercial, industrial and public sector washroom environments where security, hygiene and cost reductions are required.
  • 3. contents welcome 4 Products and Services 4 Water Efficiency 5 Our Commitment 5 BREEAM 6 SECTORS education 9 Products 10 Case Study 12 BREEAM Education 13 healthcare 15 Products 16 Case Study 18 BREEAM Healthcare 19 secure environments 21 Products 21 BREEAM Prisons 22 public, commercial & hospitality facilities 23 Products 24 BREEAM 27 OUR PRODUCTS urinal flushing 33 Hydraulic Valve 34 Infrared Control Valve (IRC valve) 36 Anti-Vandal Urinal Flush Control 38 Direct Flush 39 wc flushing 43 Easyflush (Wave and Walkaway) 44 Easyflush Direct 48 Anti-Vandal WC Flushing 52 taps and showers 53 Novatap 54 Novaspout 54 Vectatap 54 Vectaspout 54 Anti-Vandal taps 58 Anti-Vandal showers 58 total washroom control systems 59 Anti-Vandal Range Valve 60 Sensazone 63 SECTORSOURPRODUCTS
  • 4. 4 …to our 2013 specification catalogue, designed as a guide to help you choose the most appropriate product for your particular application. welcome… Cistermiser produces a range of products which control all the water outlets in a commercial washroom. Several of our products can also be used in domestic applications. products & services urinal flush control Our range of urinal flush control valves includes the hydraulic urinal flush control valve, and electronic infrared valve for use in urinal installations where a cistern is used to flush the urinals. The direct flush urinal valve is an ‘intelligent’ product which detects when someone is using the urinal and only flushes after that person has left it. This valve has been specifically designed for flushing urinals directly from the (mains) water supply. WC flush control easyflush is a no-touch WC flushing valve with dual flush from a single sensor. We also offer a secure av (anti-vandal) touch button controlled WC flush valve. taps and showers Cistermiser’s range of infrared taps, the novatap, novaspout and vectaspout, can be either basin or panel-mounted. Our av (anti-vandal) taps and showers provide a robust solution for environments where vandalism is a concern. av range This is a secure range of products designed for use in high risk and challenging environments. This complete washroom solution offers robust, heavy duty, vandal-proof shower spouts, basin spouts, urinal and WC flushing. washroom control Cistermiser’s sensazone range controls the water supply, lighting and extractor fans within the washroom. Our sensazone product controls the supply of hot, cold and rain or grey water into the washroom, isolating the supplies in vacant periods. limescale prevention Cistermiser also manufactures the combimate, a limescale prevention device, for use with combination boilers and whole house water heaters in domestic settings. Please ask us for details. All of Cistermiser’s products can be used in conjunction with rain or grey water where applicable. sales Our Sales team can answer any pre- installation queries regarding our products, to discuss specific requirements or arrange site surveys. technical support Our Technical Support team is trained to deal with any technical queries or issues with our products post-installation. The team also conducts CPD presentations covering washroom management, the water regulations and BREEAM compatibility. quality & warranty information All Cistermiser products are WRAS approved and the company is ISO 9001:2008. All products have a one year parts only warranty from the date of manufacture. The warranty can be extended, free of charge, to three years from date of installation by returning the completed warranty card after commissioning the product. The catalogue is divided into two main sections. sector specific section Detailed information about the suitability of our products for a variety of environments ranging from school and healthcare washrooms to secure facilities. product section A comprehensive technical overview of all our products, along with up-to-date information on water conservation, hygiene requirements and the environmental performance of buildings.
  • 5. 5 “The key to water efficiency is reducing waste, not restricting use.” WATERWISE Despite the chronic shortage of water storage facilities in the UK, each individual still uses approximately 150 litres per day; this figure increases to over 3,400 litres per person every day when embedded water consumption is considered. • Water usage in the UK has been rising by 1% a year since 1930. • 1.2 billion litres of water are flushed needlessly away every day in the UK. • Urinals operating without flush controls can use up to 160,000 litres of water a year. • Millions of WCs installed in the UK have a flush capacity of 13 litres or even more. • A conventional tap installed on typical commercial premises can use over half a million litres of water a year. Water Efficiency Rating IRC DF None very water efficient not water efficient 0-30 30-60 60-90 90-120 120-160 23 28 158 Note: in 1,000s of litres water efficiency our commitment Cistermiser has a long established record of dedication to conserving water; our first water saving product was launched soon after the 1976 drought. We have always recognised the need to reduce water wastage and our product range reflects this commitment. Our infrared range of products has been recognised as “water efficient” under the Waterwise Marque and the BMA Water Efficient Product Labelling Scheme (WEPLS). We have developed a water efficiency rating chart to show just how much water our products save compared to standard products. The chart below indicates the achievable savings as a result of installing one of our urinal flush controls (see pages 34 and 36 for more details). These details are available for all of our products in the product section of this catalogue.
  • 6. 6 These versions all look at the same broad range of environmental impacts: • Management • Health and Wellbeing • Energy • Transport • Water • Material and Waste • Land use and Ecology • Pollution Credits are awarded in each of the above areas according to performance. A set of environmental weightings then enables the credits to be added together to produce a single overall score. The building is then rated on a scale of: PASS, GOOD, VERY GOOD, EXCELLENT or OUTSTANDING and a certificate is awarded to the development. As part of our commitment to water conservation, we have assessed how our products can help a building design achieve BREEAM credits and hence a higher overall BREEAM rating. To achieve an OUTSTANDING rating for example, a building design will need to obtain 2 credits under the Wat 1 category. You will find further details, which can also be used to justify your choice of products, in the sector section of the catalogue under: • Education • Healthcare • Secure Environments • Public, Commercial and Hospitality Facilities BREEAM (Building Research Establishment Environmental Assessment Method) buildings can be used to assess the environmental performance of any type of building (new and existing). Standard versions exist for common building types. Less common building types can be assessed against tailored criteria under the Bespoke BREEAM version. Buildings outside the UK can also be assessed using BREEAM International. The BREEAM Pre-Assessment estimators outline the requirements to achieve BREEAM credits. To download the estimators you will need to register on: www.breeam.org/index.jsp helpful links to BREEAM and Cistermiser information: Further information on the BREEAM categories and how Cistermiser products can help achieve BREEAM credits within the categories is available to view and download on: www.cistermiser.co.uk/breeam.aspx
  • 7. 7 education Products Case Study BREEAM Education healthcare Products Case Study BREEAM Healthcare an extensive range of products each with a comprehensive technical overview sectors p.9 p.15 secure environments Products BREEAM Prisons public, commercial & hospitality facilities Products Case Study & BREEAM p.21 p.23 0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk SECTORS
  • 8. 8
  • 9. Cistermiser recognises the demanding requirements of educational settings and has developed products to combat common problems within washrooms, such as poor hygiene practices and water wastage caused by accidental and deliberate vandalism. automated solutions for school washrooms education 9 education 0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk SECTORS
  • 10. These are the minimum standards that the Department for Education would expect to be adopted in a school: • The taps should be wall mounted to avoid the dirt and germ build up that can occur around deck-mounted taps. • Taps should be WRAS approved. Source: Standard specifications, layouts and dimensions • The taps should be sensor operated and turn off automatically with less than one litre of use. This will help avoid the germ transfer that happens with more traditional touch operated mechanisms. It will also save water and minimise the risk of potential flooding. novaspout 10 infrared taps The novaspout and vectaspout are no-touch infrared panel-mounted basin outlets. They are activated when a user’s hands are presented to the infrared sensor. The outlets are fully automated and are activated by the movement of the user’s hands. Periodic hygiene rinses reduce the risk of microbial contamination such as legionella. Cistermiser also makes the novatap and vectatap, deck- mounted basin outlets for simple retrofit or where panel mounting is not an option. The novatap, novaspout, vectatap and vectaspout automatically switch off two seconds after the user’s hands are moved away, for example, while applying soap after wetting the hands, eliminating the wasted water from excessive run-on as happens with percussion (“push”) or traditional taps. The anti-vandal feature closes the taps after 60 seconds of continuous flow. This is helpful if, for example, chewing gum is placed over the sensor.
  • 11. SECTORS easyflush wc flush valve The easyflush wave and walkaway valves provide no-touch flushing and filling of the WC. The wave is operated by the user passing their hand in front of the sensor while the walkaway is automatically activated when the user stands up or leaves the cubicle. The risk of smells associated with residue left in WCs when users forget or omit to flush is therefore eliminated. The easyflush inlet float valve operates with a delayed action, which only allows the cistern to begin refilling after it has been completely emptied and the outlet valve has closed. easyflush also includes programmable part and full flushes, which allows the installer to minimise the amount of water required during each flush, but ensures sufficient water is provided. direct flush urinal flush valve The direct flush provides a no-touch flush control to each urinal individually from the mains water supply. The direct flush valves provide intelligent automatic flushing of each individual urinal after use, ensuring the highest level of hygiene from the minimum volume of water. The flush of water rinses the urinal bowl and changes the contents of the waste trap, eliminating the risk of undesirable smells. Each flush only uses 0.5 litres of water. The valves are especially effective in reducing water wastage in washrooms with low frequency usage. sensazone sensazone is a simple but effective management system to control the water, lighting and extractor fans within the washroom. Occupancy is constantly monitored by up to 10 PIR sensors strategically placed throughout the washroom. When someone enters the washroom, all services controlled by sensazone are activated; the hot and cold water solenoids open, lighting is switched on (if necessary), the extractor fans start turning and the internal timers begin counting. Every service system in the washroom is set to run for a fixed time or ‘service cycle’, which is determined by the installer. If no further movement is detected the washroom services are shut down. As sensazone controls water at its entry point, the water is prevented from passing uncontrolled through any defective or damaged outlet, eliminating the risk of wastage or flooding during vacant periods. sensazone direct flush discreet urinals in school washrooms As highlighted by the Bog Standard campaign, the use of urinals in schools can be problematic for pubescent boys. Cistermiser recognises these issues and supports the need for individual partitioning and improved hygiene conditions at urinal bowls. education 11 easyflush SECTORS
  • 12. case study cathays high school, cardiff location Cathays High School is a mixed comprehensive school for 11 to 19 year olds serving the heart of Cardiff. As is the case with many progressive schools, Cathays High elects a School Council made up of elected representatives from all year groups. They meet to discuss and act upon ideas to improve the school. One wish passed on from all age groups was to seek a method of improving the flushing of toilets. the project Research into ways of remedying this problem led to consideration of Cistermiser’s ‘hands free’ flushing system already in successful use in other schools and colleges. Mr Gavin Bryant, the Schools Mechanical Advisory Officer for Cardiff County Council suggested that Cistermiser be invited to demonstrate the easyflush system, and the company immediately sent a team to the school to review the problem first hand. The suggestion of using the Cistermiser easyflush system in the usual ‘wave’ mode, where the user simply passes a hand in front of the infrared sensor to activate a flush, was not considered wholly satisfactory. It was felt that this could be easily ignored as with manual flushing, so the team went back to talk to Cistermiser’s R & D Department, which was already investigating other methods of flush activation. the solution The need was for a flush system that could be activated automatically without any effort on the part of the user. Cistermiser’s solution was to adopt the easyflush system but with walkaway operation. Under this new mode of operation a flush is automatically triggered whenever a user gets up or walks away from the toilet. However it can also be activated by the user bringing their hand toward the sensor. The IR sensors operate on a dual flush system, delivering a part flush if the user leaves within 40 seconds or a full flush if that period is exceeded. The ‘walkaway’ method is simple, hygienic and economical since it restricts water use to a minimum. As a trial the Cistermiser Team fitted four of the cubicles used by the boys with easyflush valves with walkaway flush activation, and it has certainly solved the problem highlighted by the students. The school was particularly pleased with the co-operation and personal service from Cistermiser, from the initial contact to the project’s completion. The easyflush toilets have now been in operation for nearly two years and have resulted in cleaner toilets and a more hygienic environment for the pupils. 12
  • 13. SECTORS infrared products The Cistermiser infrared range can help a building design gain BREEAM credit ratings under the Water and Health & Wellbeing categories. performance • Standard 6 litre full flush with an adjustable part flush giving an effective flush volume of 4.5 litres. • Provides a linked flush and fill function of fittings (delayed action inlet valve operation). • Full flush adjustable to 4 litres with a subsequent reduction in part flush giving an effective flush volume of 3 litres. • Each flush uses less than 0.5 litres. • Flush arrest function to reduce water consumption further during periods of high use. • Programmable for flush duration and sensing range, and has a hygiene rinse function. • Cleaner’s function. • Regulated flow of either 5 litres or 3.5 litres per minute. • Programmable run-on. • Used with Thermostatic Mixing Valves, the periodic hygiene rinse function prevents the warm, mixed water from stagnating. • Reduces the risk of microbial contamination such as legionella. BREEAM category Wat 1 Where evidence provided demonstrates that the specification includes taps, urinals, WCs and showers that consume less potable water in use than standard specifications for the same type of fittings. Hea 12 Where hot and cold water systems have been designed or actions taken to minimise risks of microbial contamination. cistermiser product easyflush WC valve direct flush (Discreet and Accessible) urinal control valve novatap, novaspout, vectatap and vectaspout basin outlets novatap, novaspout, vectatap and vectaspout basin outlets BREEAM Education helps schools and further education colleges to set environmental targets for new and refurbished education buildings. Please refer to our website www.cistermiser.co.uk/breeam for further information on the BREEAM categories and a more detailed explanation of how the credits are achieved. It also serves as a useful tool for designers by demonstrating the environmental performance of their designs. Assessments can be carried out at the design stage and verified post-construction for primary and secondary schools and further education colleges including the following: • New schools • Major refurbishment projects • Extensions The development of BREEAM Education was driven by the Sustainable Development Action Plan, which called for both new build and refurbishment projects to achieve no less than a BREEAM ‘VERY GOOD’ rating. education 13
  • 14. performance • Controls the lighting in the washroom zone so that lights are on only when users are present. • Lighting is automatically switched on when a user is detected. • A daylight sensor is fitted within the unit to provide switching only when the level of natural lighting is insufficient. • The system offers proximity shut off of both hot and cold water supplies to the washroom • The unit provides proximity shut off for the hot and cold and rain/grey water supply. BREEAM category Hea 6 Where evidence provided demonstrates that, in all relevant building areas, lighting is appropriately zoned and occupant controllable with the option for commonly required lighting settings to be selected quickly and easily. Ene 4 Where energy efficient external luminaires are fitted and all light fittings are controlled for the presence of daylight. Wat 4 Where evidence is provided to demonstrate that proximity detection shut off is provided to the water supply to all toilet areas. cistermiser product sensazone sensazone sensazone sensazone washroom control The Cistermiser sensazone range helps building designs gain BREEAM credit ratings under three distinct categories as well as providing additional washroom management functions. performance • Standard 6 litre full flush with an adjustable part flush giving an effective flush volume of 4.5 litres. • Full flush adjustable to 4 litres with a subsequent reduction in part flush giving an effective flush volume of 3 litres. • Each flush uses less than 0.5 litres. • Flush arrest function to reduce water consumption further during periods of high use. • Programmable flush duration. • Hygiene rinse function. • Basin outlet flow control set at 1.7 litres per minute. • Shower outlet flow control set at 7 litres per minute. • Used with Thermostatic Mixing Valves, the periodic hygiene rinse function prevents the warm, mixed water from stagnating. • Reduces the risk of microbial contamination such as legionella. BREEAM category Wat 1 Where evidence provided demonstrates that the specification includes taps, urinals, WCs and showers that consume less potable water in use than standard specifications for the same type of fittings. Hea 12 Where hot and cold water systems have been designed or actions taken to minimise risks of microbial contamination. cistermiser product av range control of easyflush WC valve av range control of direct flush urinal control valve av basin outlets and showers av basin outlets and showers av range The Cistermiser av range can help a building design achieve specific BREEAM credits under the Water and Health & Wellbeing categories whilst providing a robust anti-vandal, anti-ligature water control package for high risk and hard use environments. Other BREEAM compatible products 14
  • 15. All of Cistermiser’s healthcare products use no-touch infrared technology and therefore provide a completely automated solution for healthcare washrooms and help to reduce cross- contamination and infection. automated solutions for healthcare washrooms healthcare 15 healthcare 0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk SECTORS
  • 16. infrared taps The novatap, novaspout, vectatap and vectaspout are no-touch infrared deck and panel mounted basin outlets. They are activated when a user’s hands are presented to the infrared sensor. The outlets are fully automated and are activated by the movement of the user’s hands. Periodic hygiene rinses reduce the risk of microbial contamination such as legionella. The infrared taps and spouts automatically switch off two seconds after the user’s hands are moved away, eliminating the wasted water from excessive run-on as happens with percussion (“push”) or traditional taps. All spouts are compliant with HTM64 when used with a Thermostatic Mixing Valve (TMV) and the 3.5l/min laminar flow outlet has been designed specifically for healthcare applications. Healthcare associated infections (HCAIs) in England are estimated to cost the National Health Service £1,000 million annually. According to a report by the National Audit Office, improved hand hygiene is the primary action required to reduce healthcare associated infection. Cistermiser understands the importance of hand hygiene within health care settings and has developed a range of infrared taps to help staff improve compliance with new guidelines. The range is also perfectly suited to patient and visitor areas within healthcare settings. novaspout 16
  • 17. SECTORSeasyflush dual flush wc valves The easyflush wave and walkaway valves provide no-touch flushing and filling of the WC. The wave is operated by the user passing their hand in front of the sensor while the walkaway is automatically activated when the user stands up or leaves the cubicle. The easyflush valves include programmable part and full flushes, which minimises the amount of water used. direct flush urinal flush control valves The direct flush valves provide ‘intelligent’ automatic flushing of each individual urinal after use, ensuring the highest level of hygiene from the minimum volume of water. The flush of water removes any waste immediately, eliminating the risk of undesirable smells. Each flush only uses 0.5 litres of water. The valves are especially effective in reducing water wastage in washrooms with low frequency and irregular usage patterns. direct flush discreet healthcare 17 easyflush wave
  • 18. case study treloar college location Treloar College, for students aged 16 or over, with physical disabilities, is specially designed not only to educate but also to help these young people to integrate into society. Situated in Holybourne near Alton in Hampshire, Treloar takes students from all over the country and provides a positive, supportive environment in which they can develop as adults. Students have a wide range of physical conditions, including those that have an associated learning difficulty. The college also caters for students with degenerative or life-limiting conditions. Many students who come to the College choose to board and because the halls are managed in a number of small units, staff and students have the opportunity to get to know each other well. There are five halls of residence, each with space for approximately 32 students, and each hall has its team of highly qualified support staff. the project Brewer House was built in July 2008 and it includes a £3.5million hall with 30 en-suite bedrooms and three communal bathrooms. It was designed by Fleet architectural practice McAllen & Penfold and built by Wilding Butler Construction Ltd of Winchester. Cistermiser worked closely with the architects and assisted with the preparation of the specification to ensure the appropriate user-friendly equipment was specified. Cistermiser’s easyflush system was selected in 16 of the bathrooms. the solution This hands-free system completely eliminates the need to rotate a handle or apply pressure on a button. It has proved immensely popular in situations where elderly or less able people are involved, and also in all sorts of public installations for its damage and vandal-proof qualities. easyflush is a WRAS approved, hygienic and simple-to-use product that employs a single infrared sensor to operate a dual flush WC valve. The user needs only to pass his or her hand slowly in front of the sensor for a part flush or hold it there for more than a second to obtain a full flush. A 12-hour hygiene flush is fitted as standard. The system conserves water as much as possible due to its default (programmable) part flush. In the case of the College, savings of 47% are expected both on costs and water consumption. The easyflush units supplied were installed using battery power, which makes them very quick to install and easy to maintain. McAllen & Penfold then put Cistermiser in touch with Tom Dunsford of Accolade Building Services, who arranged a site visit so that the optimum positioning of the cisterns to be used could be established. Cistermiser also tested one of the unusually small cisterns in their workshop to ensure that it was fully compatible with the easyflush system. This hands-on approach continued even after all the valves were installed. A representative of Cistermiser visited the College’s Facilities Department, gave a presentation on the easyflush product and answered questions on a wide range of topics associated with the product. The easyflush system is operating perfectly and has been greatly appreciated by the students. No direct phone calls have been necessary. 18
  • 19. SECTORS infrared products The Cistermiser infrared range of products can help a healthcare building design gain BREEAM credit ratings under the water category and offers additional health, safety and maintenance benefits. performance • Standard 6 litre full flush with an adjustable part flush giving an effective flush volume of 4.5 litres. • Provides a linked flush and fill function of fittings (Delayed action inlet valve operation). • Full flush adjustable to 4 litres with a subsequent reduction in part flush giving an effective flush volume of 3 litres. • Each flush uses less than 0.5 litres. • Flush arrest function to reduce water consumption further during periods of high use. • Programmable for flush duration, sensing range and has a hygiene rinse function. • Cleaner’s function. • Regulated flow of either 5 litres or 3.5 litres per minute. • Programmable run-on. • Used with Thermostatic Mixing Valves, the periodic hygiene rinse function prevents the warm, mixed water from stagnating. • Reduces the risk of microbial contamination such as legionella. BREEAM category Wat 1 Where evidence provided demonstrates that the specification includes taps, urinals, WCs and showers that consume less potable water in use than standard specifications for the same type of fittings. Hea 12 Where hot and cold water systems have been designed or actions taken to minimise risks of microbial contamination. cistermiser product easyflush WC valve direct flush (Discreet and Accessible) urinal control valve novatap, novaspout, vectatap and vectaspout basin outlets novatap, novaspout, vectatap and vectaspout basin outlets Note: Waterless urinals. Due to overriding health and safety concerns in some healthcare facilities, the specification of waterless urinals may not be feasible. In such cases, the lowest hygienic water consumption by urinals can be achieved with other products such as ultra low flush volume or infrared proximity-sensing urinal flush controls. Cistermiser’s Direct Flush products will deliver the appropriate levels of hygiene and water consumption and earn the same BREEAM credits. Please refer to our website www.cistermiser.co.uk/breeam for further information on the BREEAM categories and a more detailed explanation of how the credits are achieved. BREEAM Healthcare can be used to assess all healthcare buildings containing medical facilities at different stages of their lifecycles. healthcare 19
  • 20. BREEAM category Hea 6 Where evidence provided demonstrates that lighting, in all occupied areas, is zoned to allow separate control. Hea 07 Where lighting controls allow commonly required lighting settings to be made quickly and easily by building occupants. Ene 4 Where energy efficient external luminaires are fitted and all light fittings are controlled for the presence of daylight. Wat 4 Where evidence is provided to demonstrate that proximity detection shut-off is provided to the water supply to all urinals and WCs. cistermiser product sensazone sensazone sensazone sensazone washroom control The Cistermiser sensazone range helps building designs gain BREEAM credit ratings under four distinct categories as well as providing additional washroom management functions. performance • Standard 6 litre full flush with an adjustable part flush giving an effective flush volume of 4.5 litres. • Full flush adjustable to 4 litres with a subsequent reduction in part flush giving an effective flush volume of 3 litres. • Each flush uses less than 0.5 litres • Basin outlet flow control set at 1.7 litres per minute. • Shower outlet flow control set at 7 litres per minute. • Used with Thermostatic Mixing Valves, the periodic hygiene rinse function prevents the warm, mixed water from stagnating. • Reduces the risk of microbial contamination such as legionella. BREEAM category Wat 1 Where evidence provided demonstrates that the specification includes taps, urinals, WCs and showers that consume less potable water in use than standard specifications for the same type of fittings. Hea 12 Where hot and cold water systems have been designed or actions taken to minimise risks of microbial contamination. cistermiser product av range control of easyflush WC valve av range control of direct flush urinal control valve av basin outlets and showers av basin outlets and showers av range The Cistermiser av range can help a building design achieve specific BREEAM credits under the Water and Health & Wellbeing categories whilst providing a robust anti-vandal, anti-ligature water control package for high risk and hard use environments. Other BREEAM compatible products performance • The system controls the lighting in the washroom zone so that lights are on only when users are present. • Users not familiar with the facility are also catered for by means of the PIR sensor lighting, which is automatically switched on when a user is detected. • The system contains a daylight sensor to provide switching only when the level of natural lighting is insufficient. • Controls proximity shut-off of the water supply to the urinals and WCs by means of the PIR sensor detecting occupancy and providing signals to close the control valves during periods of no occupation. 20
  • 21. anti-vandal range Cistermiser’s av range is easy to install and is designed to offer the highest possible levels of tamper-proof security and remote control, while at the same time saving water and minimising running costs through the use of latching solenoids. The user interface is a stainless steel encased piezo touch button which is fitted flush with the mounting surface. The basin spouts and shower heads are also made from stainless steel and come with anti-rotation washers and pins. There is a range of specially contoured anti-ligature versions of the basin spouts and shower heads for use in locations where self-harm is a real concern. The highly versatile av range includes three styles of shower head, two styles of wall mounted basin spout, a combined flush and fill valve for WC cisterns with the option of supply within a pre-configured cistern, a direct flushing urinal valve, a six channel controller and a power supply unit. secure environments 21 anti-vandal range of washroom controls secure environments Cistermiser has developed a range of washroom products to meet the demanding requirements of environments such as prisons and secure hospitals. Our products have been designed to impede deliberate vandalism, acts of aggression towards others and attempts to self-harm. The entire range of products provides vandal-resistant touch controlled water delivery to washrooms. 0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk SECTORS
  • 22. performance • Standard 6 litre full flush with an adjustable part flush giving an effective flush volume of 4.5 litres. • Full flush adjustable to 4 litres with a subsequent reduction in part flush giving an effective flush volume of 3 litres. • Each flush uses less than 0.5 litres. • Basin outlet flow control set at 1.7 litres per minute. • Shower outlet flow control set at 7 litres per minute. • Used with Thermostatic Mixing Valves, the periodic hygiene rinse function prevents the warm, mixed water from stagnating. • Reduces the risk of microbial contamination such as legionella. BREEAM category Wat 1 Where evidence provided demonstrates that the specification includes taps, urinals, WCs and showers that consume less potable water in use than standard specifications for the same type of fittings. Hea 12 Where hot and cold water systems have been designed or actions taken to minimise risks of microbial contamination. cistermiser product av range control of easyflush WC valve av range control of direct flush urinal control valve av basin outlets and showers av basin outlets and showers washroom control range The Cistermiser washroom control range helps building designs gain BREEAM credit ratings under the Water category as well as providing additional washroom management functions. performance • Controls proximity shut-off of the water supply to the urinals and WCs by means of the PIR sensor detecting occupancy and providing signals to the control valves during periods of no occupation. BREEAM category Wat 4 Where evidence is provided to demonstrate that proximity detection shut off is provided to the water supply to all urinals and WCs. cistermiser product sensazone BREEAM prisons can assess high and standard security prisons, young offenders’ institutions, local prisons and women’s prisons at the design stage and post construction. av range The Cistermiser av range can help a building design achieve specific BREEAM credits under the water category whilst providing a robust anti-vandal, anti-ligature water control package for high risk and hard use environments. 22
  • 23. All of Cistermiser’s products are suitable for washrooms that provide services to the general public. including offices, leisure centres, public and industrial buildings public commercial & hospitality facilities 23 public, commercial & hospitality facilities 0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk SECTORS
  • 24. urinal flushing The hydraulic valve is an automatic urinal flush control valve. The valve uses a simple patented mechanism which prevents water waste by ensuring that the auto-flush cistern is only filled, and can only flush, when the washroom is used. The infrared urinal flush control (IRC) valve automatically manages the supply of water to a urinal cistern. The PIR sensor detects movement and activates the solenoid valve, only allowing water into a urinal cistern when the washroom is in use. This reduces water consumption by up to 80%. The 12-hour hygiene improves cleanliness. Cistermiser’s products deliver a range of benefits into larger washrooms and municipal facilities. 24 av urinal flush The av urinal flush control valve is part of a complete washroom management system, the av range. The touch-activated piezo button is the only visible part of the system. It is ligature resistant and has no moving parts. The piezo button cannot therefore be rotated or removed. When the button is touched it causes an electronically operated valve to open and allow water to flush the urinal. The direct flush valves provide ‘intelligent’ automatic flushing of the individual urinal after use, ensuring the highest level of hygiene from the minimum volume of water. The flush of water removes any waste immediately, therefore eliminating the risk of undesirable odours or build-up of calcium urate in the trap. reduced water consumption Our urinal cistern flushing products control water consumption in gents’ washrooms. improved hygiene No-touch controls of all washroom outlets (urinals, WCs and taps) using infrared technology. anti-vandal The av range provides a complete solution where accidental and deliberate acts of vandalism are prevalent. environmentally efficient Our sensazone range ensures that the water supply, extractor fans and lighting are only active when the washroom is in use, thus reducing energy and eliminating any risk of wastage or undetected flooding. irc valve (ceiling mount kit)
  • 25. SECTORS av range public, commercial & hospitality facilities 25 wc flushing The easyflush wave and walkaway valves provide no-touch flushing and filling of the WC. The wave is operated by the user passing their hand in front of the sensor while the walkaway is automatically activated when the user stands up or leaves the cubicle. The av WC flush control valve is part of the av range, which was designed to offer the highest possible levels of tamper-proof security and remote control while at the same time saving water and minimising running costs through the use of latching solenoids. The user interface is a stainless steel encased piezo touch button which is fixed flush with the mounting surface. This specialist vandal-resistant system includes a combined flush and fill valve for WC cisterns with the option of supply within a pre-configured cistern. taps and showers The novaspout and vectaspout are no-touch panel-mounted basin spouts. They are activated when a user’s hands are presented to the infrared sensor which is positioned below the spout. The robust and highly versatile anti-vandal range of products includes three styles of wall and ceiling shower heads and two styles of panel mounted basin spout. The user interface is a stainless steel encased piezo touch button which is fixed flush with the mounting surface. The basin spouts and shower heads are also made from stainless steel and come with anti-rotation washers and pins. There is a range of specially contoured anti-ligature versions of the basin spouts and shower heads for use in locations where self-harm is a real concern. novaspout
  • 26. washroom control sensazone is a simple but effective management system to control primary services within the washroom. Occupancy is constantly monitored by up to 10 PIR sensors strategically placed throughout the washroom. When someone enters the washroom all services controlled by sensazone are activated; the hot and cold water solenoids open, lighting is switched on (if necessary), the extractor fans start turning and the internal timers begin counting. Every service system in the washroom is set to run for fixed time or ‘service cycle’ which is determined by the installer. If no further movement is detected the washroom services are shut down. This ensures that the washroom services remain active when facilities are required and remain inactive when they are not. 26 sensazonesensazone save water sensazone controls water flow with solenoid valves. If motion is detected the valves open to supply water to urinals and cisterns. If no movement is detected for a pre-set period (configurable to 15 or 30 minutes), water supply is cut off. As sensazone controls water at its entry point, the water is prevented from passing uncontrolled through any defective or damaged outlet, eliminating the risk of wastage or flooding during vacant periods. reduce energy sensazone’s automatic shut-down facility eliminates unnecessary energy use. This efficiency is achieved through reducing lighting and extractor fan usage. The power supply to the lighting will action when sensazone detects that the washroom is occupied and when ambient light falls below a level configurable by the user. Power will continue to be supplied for either a 0, 15 or 30 minute period, depending on preference. Extractor fan operation can also be configured; users have the option of using sensazone to control the fan run-on time, or using the fan unit’s own timer facility (dependent on model selected). sensazone is supplied with a remote-control handset that makes setting the system quick and easy. vectaspout
  • 27. SECTORS 27 Please refer to our website www.cistermiser.co.uk/breeam for further information on the BREEAM categories and a more detailed explanation of how the credits are achieved. Cistermiser products can help gain BREEAM points within the water section of the BREEAM buildings assessment: av range infrared products sensazone BREEAM retail BREEAM courts BREEAM offices breeam retail BREEAM retail can assess new build or major refurbishment, post-construction, tenant fit-out, existing (occupied), management and operation. breeam courts BREEAM courts can be used to assess and certify the environmental impacts of projects for the following types of courts: crown, criminal, county, magistrates, family, youth, combined courts and civil justice centres. breeam offices BREEAM offices assessments can be carried out on new build, major refurbishment and fit out of both new and existing office buildings – either vacant or occupied. BREEAM offices is also applicable to BREEAM Industrial with the exception of Hea 06 and Ene 4 in the working areas of the building, although office areas of an industrial building will be assessed under BREEAM offices
  • 28. 28 infrared products The Cistermiser infrared range can help a building design gain BREEAM credit ratings under the Water and Health Wellbeing categories. performance • Standard 6 litre full flush with an adjustable part flush giving an effective flush volume of 4.5 litres. • Provides a linked flush and fill function of fittings (Delayed action inlet valve operation). • Full flush adjustable to 4 litres with a subsequent reduction in part flush giving an effective flush volume of 3 litres. • Each flush uses less than 0.5 litres. • Flush arrest function to reduce water consumption further during periods of high use. • Programmable for flush duration, sensing range and has a hygiene rinse function. • Cleaner’s function. • Regulated flow of either 5 litres or 3.5 litres per minute. • Programmable run-on. • Used with Thermostatic Mixing Valves, the periodic hygiene rinse function prevents the warm, mixed water from stagnating. • Reduces the risk of microbial contamination such as legionella. BREEAM category Wat 1 Where evidence provided demonstrates that the specification includes taps, urinals, WCs and showers that consume less potable water in use than standard specifications for the same type of fittings. Hea 12 Where hot and cold water systems have been designed or actions taken to minimise risks of microbial contamination. cistermiser product easyflush WC valve direct flush (Discreet and Accessible) urinal control valve novatap, novaspout, vectatap and vectaspout basin outlets novatap, novaspout, vectatap and vectaspout basin outlets public, commercial hospitality facilities 28
  • 29. SECTORS 29 performance • Controls the lighting in the washroom zone so that lights are on only when users are present. • Lighting is automatically switched on when a user is detected. • A daylight sensor is fitted within the unit to provide switching only when the level of natural lighting is insufficient. • The system controls proximity shut off of the hot and cold water supply to the urinals, taps and WCs. • The unit can also provide proximity shut off for the hot and rain/grey water supply. BREEAM category Hea 6 Where evidence provided demonstrates that, in all relevant building areas, lighting is appropriately zoned and occupant controllable with the option for commonly required lighting settings to be selected quickly and easily. Ene 4 Where energy efficient external luminaires are fitted and all light fittings are controlled for the presence of daylight. Wat 4 Where evidence is provided to demonstrate that proximity detection shut off is provided to the water supply to all toilet areas. cistermiser product sensazone sensazone sensazone sensazone washroom control The Cistermiser sensazone range helps building designs gain BREEAM credit ratings under four distinct categories as well as providing additional washroom management functions. performance • Standard 6 litre full flush with an adjustable part flush giving an effective flush volume of 4.5 litres. • Full flush adjustable to 4 litres with a subsequent reduction in part flush giving an effective flush volume of 3 litres. • Each flush uses less than 0.5 litres • Programmable flush duration. • Hygiene rinse function. • Cleaner’s function. • Basin outlet flow control set at 1.7 litres per minute. • Shower outlet flow control set at 7 litres per minute. • Used with Thermostatic Mixing Valves, the periodic hygiene rinse function prevents the warm, mixed water from stagnating. • Reduces the risk of microbial contamination such as legionella. BREEAM category Wat 1 Where evidence provided demonstrates that the specification includes taps, urinals, WCs and showers that consume less potable water in use than standard specifications for the same type of fittings. Hea 12 Where hot and cold water systems have been designed or actions taken to minimise risks of microbial contamination. cistermiser product av range control of easyflush WC valve av range control of direct flush urinal control valve av basin outlets and showers av basin outlets and showers av range The Cistermiser av range can help a building design achieve specific BREEAM credits under the Water and Health Wellbeing categories whilst providing a robust anti-vandal, anti-ligature water control package for high risk and hard use environments.
  • 30. 30 Cistermiser has many years of experience working with a wide range of industries, and our expert team is always on hand to offer advice on the best solutions for your sector. Our case studies show how we frequently use our expertise to create bespoke solutions for our customers, and we’d be happy to discuss your needs. For more information, get in touch with Cistermiser today: call 0118 969 1611 email sales@cistermiser.co.uk visit cistermiser.co.uk our sectors
  • 31. 31 urinal flushing Hydraulic Valve Infrared Control Valve (IRC Valve) AV Urinal Flush Control Direct Flush wc flushing Easy Flush (Wave and Walkaway) AV WC Flushing taps and showers Novatap Novaspout Vectatap Vectaspout AV taps AV showers an extensive range of products each with a comprehensive technical overview our products p.33 p.43 p.53 total washroom control systems AV Range Valve Sensazone p.59 0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk OURPRODUCTS
  • 32. 32
  • 33. urinal flushing 33 urinal flushing hydraulic valve irc valve anti-vandal urinal direct flush 0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk OURPRODUCTS
  • 34. • Automatic urinal flush control • Unique patented hydraulic mechanism – no electrical supply or batteries required • Industry leader with half a million already installed • ‘Fit and forget’ quality and reliability • Hygiene flush option for periods of non-use • Ensures compliance with the Water Regulations • On DEFRA’s ECA Water Technology List; purchase and installation are tax deductible reduces water consumption and washroom odours hydraulic valve urinal flush control valve The hydraulic valve is an automatic urinal flush control valve. The valve uses a simple patented mechanism which prevents water waste by ensuring that the auto-flush cistern is only filled, and can only flush, when the washroom is used. how it works The Cistermiser hydraulic valve is installed on the supply pipe to the urinal cistern. The valve is activated by short-term pressure drops created by use of taps or WCs on the same supply. The valve is normally closed; when it is activated it opens and water passes to the urinal cistern until the pressures on both sides of the valve are equalised. When the cistern is full, the auto-siphon will flush. product information • The valve is installed on the supply pipe to the urinal cistern. • The installer or user can adjust the time the valve remains open and therefore how long the cistern takes to fill and how much water is used. When the washroom is not being used the water supply pressure remains constant and the valve remains closed, preventing water passing into the cistern. • The cistern can therefore only flush during periods when the washroom is in use, eliminating unnecessary water consumption and cost. 34
  • 35. specification wording The mechanical contractor shall supply and install a urinal flushing device of the ‘Cistermiser Hydraulic Valve’ type on the supply pipe to the urinal cistern, as shown on the drawing. The flushing control device shall be a mechanical, hydraulic device operated by changes in system pressure due to demand on connected water services within the washroom. standard valve The flushing control device shall be suitable for supply system pressures of between 0.5 and 6.0 bar (typically either mains water or tank-fed systems above 5m head). low pressure valve The flushing control device shall be suitable for supply system pressures of between 0.3 and 0.5 bar (typically tank-fed systems between 3m and 5m head). high sensitivity low pressure valve The flushing control device shall be suitable for supply system pressures of between 0.05 and 0.3 bar (typically tank-fed systems between 0.5m and 3m head). The above flushing control device shall be as manufactured by: Cistermiser Limited Unit 1, Woodley Park Estate, 59 – 69 Reading Road, Woodley, Reading, RG5 3AN Tel: 0118 969 1611 product codes standard hydraulic valve: STD standard hydraulic valve with hygiene flush: STDIF low pressure hydraulic valve: LP low pressure hydraulic valve with hygiene flush: LPIF high sensitivity low pressure valve: HSLP The Cistermiser hydraulic valve consists of three main elements, as shown left. Diaphragm operated valve which, when opened, allows water to pass to the urinal cistern. Hydraulic accumulator which, if fully charged, will maintain an equal supply-pressure on both sides of the diaphragm. When pressure on the inlet side is reduced, as other services are used, the pressure imbalance causes the valve (1) to open. Adjuster (restrictor) screw which can be set during installation to determine the volume of water discharged into the cistern at each operation by altering the duration of the ‘open’ period. choosing the right valve for your application Three models make up the range of hydraulic valves, each suited to a different range of water supply pressure. This table will help to specify the right model for your application. Colour coded Operating packaging Model Supply sensitivity Standard Valve Mains water or 15% of supply tank-fed systems pressure ...with Hygiene Flush above 5m head Low Pressure Valve Tank-fed systems, 20% of supply 3m to 5m head pressure ...with Hygiene Flush High Sensitivity Tank-fed systems, 20% of supply Low Pressure Valve 0.5m to 3m head pressure hygiene cycle In buildings where the washrooms are vacant for long periods, a hygiene cycle attachment is available to ensure a regular flush every 12 hours to prevent washroom odours. The bypass screw should be set to permit a slow drip into the cistern to initiate a flush approximately every 12 hours. For correct operation it is essential that the siphon of the auto flushing cistern does not leak. 1 2 3 1 2 3 urinal flushing Note: The user can control the amount of water allowed to pass through the valve each time it is activated; most users choose a range between 0.5 and 10 litres per flush. 35 OURPRODUCTS
  • 36. • Ensures compliance with the Water Regulations • Can be concealed to reduce the risk of vandalism • Mains or battery powered options in the same box: no external transformer required • Pipe, wall or ceiling mounted sensor: surface mounted or recessed • On DEFRA’s Water Technology List; purchase and installation are tax deductible reduces water consumption by up to 80% irc valve cistern-flushing urinal valve with motion-sensing infrared The infrared urinal flush control (IRC) valve automatically manages the supply of water to a urinal cistern. The PIR sensor detects movement and activates the solenoid valve, allowing water into a urinal cistern. how it works The infrared urinal flush control (IRC) consists of a solenoid valve and the sensor module. When the IRC detects movement in the washroom, a pulse from the sensor opens the normally-closed solenoid valve and water flows to the cistern; at the same time the sensor is switched off. After 25 minutes the power is restored to the sensor and, as long as no movement is detected for 5 minutes, the solenoid valve closes, shutting off the water supply to the cistern. product information • The solenoid assembly is plumbed in on the water supply to the urinal cistern. The connection to the infrared sensor is made either by directly mounting the sensor module on to the solenoid or by using the ‘floating socket’ supplied for a remote mounting. If mounted remotely, the sensor module may be: – Surface mounted using a standard pattress box. – Recessed into a suspended ceiling using the ‘ceiling mounting kit’ (CMK), supplied with the IRC as standard. • If the sensor detects no occupancy in 12 hours it will automatically open the valve for 30 minutes to allow one flush of the cistern to rinse the urinals and pipework. • The sequence is designed to maximise battery life, giving approximately 3 years’ life from one good quality set of batteries. • The flow rate of the water into the cistern is adjustable to maximise water economy. Generally this should be set so that the cistern flushes once every time the valve is opened. i.e. every 30 minutes during occupation. • The solenoid is supplied with an interchangeable valve seat which is used to increase the flow to the cistern on low pressure supplies. 36 irc valve (ceiling mount kit)
  • 37. reducing water wastage and costs Urinals often flush regardless of use, wasting a lot of water, especially out of hours. Installing a Cistermiser IRC valve can save on average 129,600 litres of water per year and reduce costs by up to £313 per urinal bowl. specification wording • The mechanical contractor shall supply and install a urinal flushing device of the ‘Cistermiser IRC’ type on the supply pipe to the urinal cistern, as shown on the drawing. • The flushing control device shall consist of a PIR sensor with a control unit and a solenoid valve with integral flow regulator and interchangeable valve seat. • The flushing control device should have a hygiene flush function for periods of low use. • The flushing control device shall be suitable for supply system pressures of between 0.1 and 6.0 bar. • The flushing control device shall be suitable for connection to either 230V, 50 Hz single phase supply or 4 x 1.5V alkaline batteries of type LR6. • The flushing control device shall have provision to be mounted directly on the pipework or remotely using either the flush mounting kit supplied or a standard electrical pattress box. The above flushing device shall be as manufactured by: Cistermiser Limited Unit 1, Woodley Park Estate, 59 – 69 Reading Road, Woodley, Reading, RG5 3AN Tel: 0118 969 1611 product code infrared urinal flush control valve: IRC2 installation options PIR sensor unit Contained within a white moulded ABS case designed to fit directly on to the solenoid valve assembly or a standard 3.25” x 3.25” (83mm x 83mm) pattress box for surface mounting. At the back there is access to the battery compartment or terminals for a 240V mains power supply to the integral and in-built transformer and the 6V DC output to the solenoid. dimensions 85 x 85 x 63.5mm (W x H x D) including the sensor lens range approx 3.5m field of view, 138˚ horizontal, 125˚ vertical solenoid voltage 6V DC nominal 54µA, peak 750mA, for 50ms mains supply 220V – 240V 50hz 20mA battery supply 4 x 1.5V Alkaline Type LR6 – Cap. 2700mAh solenoid valve 6V latching valve, UK WRAS approved. One valve per sensor. water supply 0.1-6 bar (For 6 bar a pressure reducing pressure valve is required). Integral, adjustable flow regulator and interchangeable valve seat. on the pipe sensor installationremote sensor installation valve insert pressure max flow min flow orifice insert litres per min litres per min 1.5mm 6 bar 2.7 0.03 1.5mm 2 bar 1.6 0.01 3.0mm 2 bar 3.0 0.05 3.0mm 0.1 bar 0.9 no flow NB 3.0mm orifice should only be fitted when fed from a tank below 5m head. urinal flushing Uncontrolled urinal IRC Litres per flush 4.5 4.5 Flushes per hour 4 2 Hours per day 24 12 Days per year 365 260 Water usage per year (ltrs) 157,680 28,080 Water saving per year (ltrs) – 129,600 Water usage per year (m3 ) 157.68 28.08 Water costs per m3 (£) 2.42 2.42 Annual water cost (£) 381.56 67.95 Annual water cost saving (£) – 313.61 37 OURPRODUCTS
  • 38. • Programmable (adjustable) flow duration • Ligature-resistant touch button • Low voltage operation from power supply with battery back-up • Robust piezo touch button • 12-hour hygiene rinse option • Anti-flood feature • Master control remote disable function • BREEAM WAT1 compatible product vandal-resistant touch controlled water delivery to washroom urinals av urinal touch activated washroom water control with no moving parts Our av urinal flush control valve, part of the Cistermiser av range, is a specialist vandal- resistant, touch-activated washroom control for use in high risk or demanding public environments such as prisons, secure hospitals, schools and sports facilities. product information • The touch buttons are made from robust AISI 316L stainless steel. They come with anti-rotation washers and pins to ensure they cannot be removed or tampered with and used for self-harm or to inflict harm on others. • The highly versatile av range includes a piezo touch button, three styles of shower head, two styles of wall mounted basin spout, a WC cistern combined flushing and filling (drop and inlet) valve, a direct flushing urinal valve, a six channel controller and a power supply unit. • The touch buttons are available in a choice of three tail lengths to accommodate panel/wall thicknesses from 17mm to 330mm. The piezo touch button is supplied with 3 metres of cable to allow maximum flexibility for sitting of the valves and control box. • System users only have access to the touch buttons. All other system components such as solenoid valves, six channel controllers and water supply pipes are located in services voids, which are inaccessible to the users. how it works The user interface is a stainless steel encased piezo touch button which is fixed flush with the mounting surface. When touched, the button causes an electronically operated valve to open and allow water to flush urinals. The flow duration for each outlet is programmed on installation. If the user touches the button for a second time, within the programmed flow period, water flow is stopped at once. There are no moving parts within the piezo touch button. The buttons are hard-wired to the AV six channel controller, which controls the outlets. Each unit can control up to six valves and each piezo touch button controls one outlet. 38
  • 39. • Designed for urinals flushing directly from the cold water supply • No cistern required • Only flushes urinal bowl after use • Vandal-resistant – valve totally concealed • Hygiene flush for periods of non-use • Adjustable flush duration and range • Discreet and Accessible fitment options • Mains and battery powered options included • Ensures compliance with Water Regulations • BREEAM WAT1 compatible product • On DEFRA’s ECA Water Technology List; purchase and installation are tax deductible the cost effective solution to maximise urinal hygiene and water economy direct flush mains-flushing urinal valve with infrared activation 39 direct flush accessible direct flush discreet OURPRODUCTS
  • 40. direct flush is an infrared sensor controlled urinal valve. The direct flush automatically flushes the individual urinal after use, ensuring the highest level of hygiene from the minimum volume of water. direct flush removes the need for the auto-flush cistern and associated plumbing used in traditional urinal installations, which flush all urinals intermittently even if they have not all been used. product information • direct flush includes an integral DC pipe interrupter (air gap), enabling the installer to connect it directly to the mains water supply. This provides fluid category 5 back- siphonage protection, without the need for any additional backflow prevention or check valves. • direct flush can be powered by either mains electricity via the DC transformer or batteries; both options are included as standard. When batteries are fitted the direct flush provides a low battery warning indicator. • A mains power supply unit (PSUC) which powers up to 20 direct flush urinal valves is also available. Only 1 fused spur is required when using this product. • Additional customised washroom settings are obtainable via a hand held remote control Infrared Configuration Unit (ICU) which is available as an optional extra. The remote controller enables rapid automatic range configuration to the specific washroom dimensions, deactivation of the hygiene flush function and, where a siphonic trap has been fitted, activation of the trap refill function. how it works The direct flush infrared sensor detects the user at the urinal bowl and flushes 2 seconds after the user departs. The LED flashes green every 3 seconds whilst a user is detected. If a user is detected whilst the water is flushing, the flush is automatically arrested to prevent splashing and wastage. During the flush, the LED flashes green once a second. The flush duration is adjustable which ensures that only the minimum amount of water necessary is used. If there has been no use of the urinal for 12 hours, the direct flush automatically runs a hygiene flush to prevent odours and the build up of uric acid in the pipework. urinal flushing40
  • 41. reducing water wastage and costs, ensuring hygiene Uncontrolled urinals may flush constantly regardless of use, wasting thousands of litres of water per year and costing hundreds of pounds per year. The direct flush is activated after every use of the urinal but only flushes 0.5 litres at a time. Cistermiser has calculated savings of 134,000 litres and up to £325 per year where a direct flush has been installed. Uncontrolled Direct Flush Direct Flush Urinal 7.5 ltrs 10 ltrs per hour per hour Litres per flush 4.5 0.5 0.5 Flushes per hour 4 15 20 Hours per day 24 12 12 Days per year 365 260 260 Water usage per year (ltrs) 157,680 23,400 31,200 Water saving per year (ltrs) 0 134,280 126,480 Water costs per m³ (£) 2.42 2.42 2.42 Annual water cost (£) 381.58 56.62 75.50 Annual water cost saving (£) 0 324.96 306.08 Water Efficiency Rating DF None very water efficient not water efficient 0-30 30-60 60-80 80-120 120-160 23 158 Note: in 1,000s of litres 41 OURPRODUCTS
  • 42. installation options direct flush accessible infrared sensor The direct flush accessible incorporates the valve and the power options as well as the sensor in a single compact box housing. It can be installed on to either a concealed structural wall / frame or on to the exposed wall panel. It is ideal where access cannot be gained to the wall cavity. The sensor plate can be removed to enable servicing of the valve or battery replacement (if battery powered) in the installed position without the need to remove the panel. direct flush discreet infrared sensor The direct flush discreet unit is an alternative installation option where rear access can be gained to the wall cavity for servicing and inspection. The valve is mounted on to the pipework behind the panel or wall together with either the mains supply unit or batteries, while the unobtrusive infrared sensor is installed directly above the urinal bowl. specification wording direct flush discreet The mechanical contractor shall supply and install a urinal flushing device of the Cistermiser DFD type for concealed installation where service access is provided externally. A Cistermiser DFD is to be fitted to each individual urinal. The flushing control device is to consist of a PIR sensor remotely mounted above the urinal and controlling a solenoid valve with an integral DC pipe interrupter to comply with Water Regulations. direct flush accessible The mechanical contractor shall supply and install a urinal flushing device of the Cistermiser DFA type for installation where service access is not provided. A Cistermiser DFA is to be fitted to each individual urinal. The flushing control device is to consist of a PIR sensor controlling a solenoid valve with an integral DC pipe interrupter to comply with water regulations. The sensor, valve and integral power supply are to be contained within a mounting unit with removable face plate to allow service access once installed. The unit is to be mounted above the urinal so that the removable face plate is flush with the finished wall surface. direct flush discreet direct flush accessible The flushing control device is to be fully configurable for flush time and duration, sensing distance, flush arrest and is to be programmable either manually or by use of the ICU (remote control) where supplied. The unit should also have a programmable periodic hygiene flush function for periods of low use and a cleaner’s function to conserve water during routine cleaning and maintenance. The flushing control device is to be suitable for connection to either 230v 50Hz AC single phase supply or from 4 x 1.5v alkaline batteries of type LR6. For multiple product installations the device is to have the option of being installed with a common power supply unit (PSUC) capable of powering several units from one 230v fused spur. The unit should be the Cistermiser direct flush as manufactured by: Cistermiser Limited Unit 1, Woodley Park Estate, 59 – 69 Reading Road, Woodley, Reading, RG5 3AN Tel: 0118 969 1611 product codes direct flush discreet: DFD direct flush accessible: DFA urinal flushing42
  • 43. wc flushing 43 wc flushing easyflush (wave walkaway) easyflush direct av wc flushing 0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk OURPRODUCTS
  • 44. • Infrared sensor operated WC cistern flush valve • Defaults to part flush of as low as 2 litres for maximum water savings • No-touch means no cross-contamination; hygienic • Installer programmable flush volumes; improved water economy • Flush (outlet) and delayed action fill (inlet) valves combined in one unit • Available in active (‘wave’) or passive (‘walkaway’) mode hands-free and water-conserving WC cistern flush and fill valve easyflush wc cistern flush valve 44
  • 45. easyflush is suitable for concealed or exposed cisterns. easyflush is easy to install in retrofits or new installations. It can also be supplied complete with its own cistern. The easyflush no-touch dual flush WC cistern valve promotes best practice in water economy and hygiene in domestic and commercial washrooms. product information • Both the wave and walkaway sensors meet the DDA requirements and are Part M compliant. • easyflush is two interlinked valves in one: a lift/drop valve which empties the cistern and a delayed action float valve which controls refilling. • It also includes an integral overflow pipe to prevent flooding. • The compact single-piece unit is located over the outlet by a bayonet-type locking device which simplifies installation. Intelligent memory feature If the user requires an additional flush they can bring their hand close to the infrared sensor to activate a further flush which will be stored in the memory and activate after the programmable cistern refill time has elapsed. how it works easyflush wave is operated by the user bringing their hand close to an infrared sensor. The dual flush mode enables the user to select either a part or full flush by the length of time their hand is in front of the sensor. For a part flush the hand is held in front of the sensor for up to one second and, for a full flush, over one second. easyflush walkaway is normally activated by the user standing up or leaving the cubicle; however, it can also be activated by the user bringing their hand toward the sensor. The walkaway version comes with the dual flush factory programmed. A part flush will be delivered if the user departs from the cubicle within 40 seconds and a full flush will be delivered if the user departs after 40 seconds. wc flushing 45 OURPRODUCTS
  • 46. reducing water wastage through delayed action UK toilets needlessly flush away 1.2 billion litres of water a day (Waterwise). The graph below (adapted from WRc data) shows that the actual flush volume for a nominal 6 litre WC increases as pressure increases. The Cistermiser easyflush will maintain the nominal volume at all pressures due to its patented delayed action operation. Installing a Cistermiser easyflush can save up to 162,000 litres per year as shown below. delayed action valve operating sequence The inlet float valve operates with a delayed action, which only allows the cistern to begin refilling after it has been completely emptied and the outlet valve has closed. This patented feature prevents an increase in the volume of water per flush. In other systems water can enter the cistern before the outlet valve has closed, thus increasing the volume of water per flush. Plunger Float Outlet Drop Valve Inlet Float Valve Water Supply Feed DISCHARGE 1 3 2 flush triggered Water pressure lifts plunger, opening outlet drop valve and holding inlet float valve in the closed position. flush finishes Outlet drop valve closes, lowering inlet float valve and cistern begins filling. unit in standby mode Once cistern is full, water holds the inlet float valve closed. 6 litre WC, standard valve 10 9 8 7 6 5 4 3 pressure, bar actualflushvolume,litres 0 2 4 6 8 10 12 46 standard wc easyflush Litres per flush (average) 9 2.8 Flushes per day per person 5 5 Number of persons 20 20 Days per year 260 260 Water usage per year (ltrs) 234,000 72,000 Water saving per year (ltrs) – 162,000 Water usage per year (m³) 234 72 Water costs per m³ (£) 2.42 2.42 Annual water cost (£) 566.28 174.24 Annual water cost saving (£) – 392.04
  • 47. installation options • easyflush is powered by 4 x 1.5V AA (LR6) batteries or a 6V DC mains adaptor which can be installed behind service panels. • The battery option allows the easyflush to be installed inside exposed cisterns. • Also available as an optional extra is a multi product mains power supply unit (PSUC) to power up to 20 sensors from a single fused spur. • The easyflush wave can be fitted into a concealed or an exposed cistern and can also be easily retrofitted. • The easyflush walkaway is only suited to concealed installations. 228mm 283mm37mm 48mm 27mm 93mm84mm 212mm Ø44mm or Ø50mm please specify flush pipe size easyflush wave exposed installation easyflush walkaway concealed installation Top WC WC Front Concealed installation 300 – 400mm 700–900mm Side Exposed installation wc flushing cistermiser concealed cistern – easy to fit The cistern is supplied with the easyflush valve already installed inside it. The installer only needs to connect to the water supply and pan. To install and commission there are three easy steps: 1 Mount the cistern directly on the wall/panel. 2 Mount the sensor through the panel or wall and fit the power source. 3 Connect the water supply and sensor leads. Access to the valve after installation is simple and obtained by removing the lid of the cistern. • Suitable for the majority of 6 litre WCs . • Available with either 38mm (1.5”) or 50mm (2”) diameter flush pipes. • Side entry water inlet supplied as standard but bottom entry also available. • Internal overflow included. cistern maximum overall dimensions (All dimensions with lid fitted) height: 335mm, width: 510mm, depth 150mm outlet options: 38mm (1.5”) or 50mm (2”) flush pipe 47 specification wording easyflush wc cistern flush valve The mechanical contractor shall supply and install a no-touch dual flush, sensor operated flush and fill delayed action valve to each WC cistern. The valve shall consist of a single remote sensor, solenoid operated flush valve and combined integral fill valve. The inlet will include a double check valve. The unit will be of a dual flush capability from one sensor and the flush volume will be adjustable both for part and full flush functions. The sensor will be programmable for operating range, part flush time, cistern refill time and part flush operation (default is for part flush to be active). The unit should also incorporate a cleaner’s function to minimise water usage during routine cleaning operations. The programming can be carried out manually by hand or by means of the optional ICU (remote control). The flush valve and inlet valve are to be linked (delayed action between inlet and outlet) to ensure that no water can enter the cistern during the flush cycle to prevent excess water usage. Compliance with BREEAM WAT1. The unit should have a periodic hygiene flush function to ensure facilities are kept in a clean and hygienic condition. The flush and fill valve is to be suitable for connection to either 230V 50Hz AC single phase supply or from 4 x 1.5V alkaline batteries of type LR6. For multiple product installations the device is to have the option of being installed with a common power supply unit (PSUC) capable of powering several units from one 230V fused spur. The unit is to be suitable for mounting in a variety of cisterns and is to be easily installed and removed for maintenance purposes via a bayonet locking device. The WC cistern flushing valves should be the easyflush wave or walkaway no-touch dual flush WC valve as manufactured by: Cistermiser Limited Unit 1, Woodley Park Estate, 59 – 69 Reading Road, Woodley, Reading, RG5 3AN Tel: 0118 969 1611 product codes easyflush wave: EF easyflush walkaway: EF/Walk easyflush wave with cistern: EF/CIST easyflush walkaway with cistern: EF/Walk/CIST OURPRODUCTS
  • 48. • No cistern required – save space • No inlet valves – reduced installation cost • No cistern refill – immediate re-flush for busy areas • Infrared sensor operated • Hygiene flush to maintain cleanliness • Range of flow rates • Compliant with Water Regulations. WRAS approved. infrared sensor activated mains flushing for WCs easyflush direct 48
  • 49. easyflush direct is an electronic flushing system for WCs that removes the need for a WC cistern, by taking its water feed straight from the mains supply. This means there is no cistern to be refilled and a second flush can be activated without a delay. A hygiene flush can also be activated to maintain the cleanliness of the WC. effective flushing To achieve an effective and efficient flush the water system needs to deliver at least 90 lpm (litres per minute). Typically this would require that the dynamic water pressure, measured before the valve, is at least 2bar. If 90 lpm cannot be achieved, the flush will be less effective and a longer flush duration or multiple flushes may be required. This can result in water wastage. If the water flow rate exceeds 150 lpm, splashing from the WC bowl may occur. easyflush direct is fitted with a flow regulator that will limit the flow rate to 100 lpm. However, additional flow regulators for 90 lpm and 125 lpm are included, to regulate the flow rate further, if required. These flow regulators are coloured coded: • Dark blue: 90 lpm • Black: 100 lpm (fitted as standard) • White: 125 lpm NOTE: Some WC bowls are designed for low volume flushing and an effective flush can be achieved at low flow rates. Please check with the WC bowl manufacturer. The flow regulator can be removed to maximize flush performance but this can lead to excessive water use. wc flushing 49 product description • easyflush direct includes a valve, DC pipe interruptor and sensor. When the sensor is activated, the valve is activated for between 2 and 3.5 seconds, supplying water to flush the WC direct from the mains water supply. After this period the valve closes and the flush is complete, but can be activated again immediately. • There are two versions to suit different applications: easyflush direct wave is operated by the user bringing their hand towards the infrared sensor. A part flush is triggered by holding one’s hand in place near the sensor for about 1 second and a full flush is triggered by a slightly longer hand pass. easyflush direct walkaway is activated when the user stands up or leaves the cubicle but it can also be activated by the user bringing their hand toward the sensor. A part flush is triggered by short user occupancy and a full flush by long user occupancy (over 45 seconds). OURPRODUCTS
  • 50. The graph below shows the approximate flow rates at a range of dynamic pressures. Flowrate(litres/min) Supply pressure (bar) 90 lpm 140 2 3 4 160 180 200 120 100 80 60 40 5 61 0 20 0 100 lpm 125 lpm No flow regulator No flow regulator 125 lpm 100 lpm 90 lpm The flush volume is determined by the flush duration and the flow rate of the water supply. Using the flow regulators and adjusting the flush duration, will allow you to configure the flush performance. However, this will differ based on the WC bowl design. The flow rate can also be reduced by turning the adjuster screw in the middle of the valve (clockwise to reduce flow) or by fitting a third party pressure reducing valve above easyflush direct. Ensure that the dynamic water pressure (pressure measured while the valve is open and water is flowing) is sufficient to achieve the required flow rate. 50
  • 51. installation options • easyflush direct is powered by a 6V DC mains adaptor which can be installed behind service panels. Also available as an optional extra is a multi-product mains power supply unit (PSUC) to power up to 20 sensors from a single fused spur. wc flushing DC pipe interrupters easyflush direct introduces an air gap into the water system. Care must be taken that pipework design and WC bowl selection is appropriate to ensure sufficient flow to flush the WC while preventing water flowing out of the air gap. This can occur when back pressure is high, caused by a restrictive connection to the WC. The valve should always be installed as high as possible on the vertical pipe feeding the WC bowl flush inlet to prevent water backing up and leaking from the DC pipe interrupter. When installing the valve it is good practice to ensure there is an accessible isolation valve upstream of the valve. Ensure flow rate at valve does not exceed the flow rate to the WC bowl, to prevent water backing-up to the DC pipe interrupter. easyflush direct is supplied with a DC pipe interrupter and a 1.5” flush pipe fitting. Fit the DC pipe interrupter to the valve outlet ensuring the rubber seal is in place. If the DC pipe interrupter is not required, fit the 1.5 flush pipe fitting to the pipe outlet in place of the DC pipe interrupter. Fittings are supplied to connect to a 38mm (1.5”) flush pipe. NOTE: Ensure the DC pipe interrupter is fitted a min of 300mm above the spill over point of the WC bowl. 51 specification wording easyflush direct flush valve The mechanical contractor shall supply and install a no- touch dual flush, sensor operated flush. The unit will be of a dual flush capability from one sensor and the flush volume will be adjustable both for part and full flush functions. The sensor will be programmable for operating range, part flush and full flush operation (default is for part flush to be active). The unit should also incorporate a cleaner’s function to minimize water usage during routine cleaning operations. The programming can be carried out manually by hand or by means of the Infrared Control Unit (not supplied). The unit should have a periodic hygiene flush function to ensure facilities are kept in a clean and hygienic condition. For multiple product installations the device is to have the option of being installed with a common power supply unit PSUC capable of powering several units from one 230V fused spur. The WC flushing valves should be the easyflush direct wave or walkaway no touch mains flushing WC valve as manufactured by: Cistermiser Limited Unit 1, Woodley Park Estate, 59 – 69 Reading Road, Woodley, Reading, RG5 3AN Tel: 0118 969 1611 product codes easyflush direct wave: EFD easyflush direct walkaway: EFD/Walk 67mm 48mm 27mm 126mm 163mm 37mm OURPRODUCTS
  • 52. av wc flushing Our av wc cistern flush control valve, part of the Cistermiser av range, is a specialist vandal-resistant, touch-activated washroom control for use in high risk or demanding public environments such as prisons, secure hospitals, schools and sports facilities. product information • The touch buttons are made from robust AISI 316L stainless steel. They come with anti-rotation washers and pins to ensure they cannot be removed or tampered with and used for self-harm or to inflict harm on others. • The highly versatile av range includes a piezo touch button, three styles of shower head, two styles of wall mounted basin spout, a WC cistern combined flushing and filling (drop and inlet) valve, a direct flushing urinal valve, a six channel controller and a power supply unit. • The touch buttons are available in a choice of three tail lengths to accommodate panel/wall thicknesses from 17mm to 330mm. The piezo touch button is supplied with 3 metres of cable to allow maximum flexibility for sitting of the valves and control box. • System users only have access to touch buttons and WC bowls. All other system components such as solenoid valves, six channel controllers, WC cisterns and water supply pipes are located in services voids, which are inaccessible to the users. how it works The user interface is a stainless steel encased piezo touch button which is fixed flush with the mounting surface. When touched, the button causes an electronically operated valve to open and allow water to flush your WC cistern. The flow duration for each outlet is programmed on installation. If the user touches the button for a second time within the programmed flow period, water flow is stopped at once. There are no moving parts within the piezo touch button. The buttons are hard-wired to the AV six channel controller, which controls the outlets. Each unit can control up to six valves and each piezo touch button controls one outlet. 52 • Programmable (adjustable) flow duration • Ligature-resistant touch button • Low voltage operation from power supply with battery back-up • Robust piezo touch button • 12-hour hygiene rinse option • Anti-flood feature • Master control remote disable function • BREEAM WAT 1 compatible product
  • 53. taps and showers 53 taps and showers novatap vectatap anti-vandal taps novaspout vectaspout anti-vandal showers 0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk OURPRODUCTS
  • 54. • Hands-free infrared basin spouts • Automatic shut-off: no drips or taps left running • Improve water and energy efficiency • Easy to use: ideal for less-abled or elderly • Hygienic: reduce risk of cross-contamination • Available in 5 litres per minute and 3.5 litres per minute models • Mains and battery powered options included • Vandal resistant • Easy to fit in new installations or retrofits save water, promote hygiene and reduce maintenance costs infrared taps novatap, novaspout, vectatap and vectaspout 54
  • 55. how it works The flow of water from the spouts is turned on when the user presents their hands to the infrared sensor which is located on the lower body of the novatap and vectatap or is positioned below the novaspout and vectaspout. No contact is required. When the user’s hands are moved away the flow of water stops after a 2 second delay. The novatap and vectatap are contemporary deck-mounted chrome basin spouts with an infrared sensor, control unit and valve integral in its body, making it extremely simple to install. The novaspout and vectaspout are elegant panel-mounted polished stainless steel basin spouts supplied with an infrared sensor control unit and valve. The Water Regulations require that the flow rate of a spout does not exceed 3.6 litres per minute where basins have no plug. The 3.5 litres per minute model therefore ensures that this spout is compliant in such applications. product information • Robust design and build quality make the spouts ideal for hard use environments where the less-abled or elderly may find it difficult to operate conventional spouts. • The spouts are particularly useful where hygiene issues coupled with water and energy efficiency are paramount. • Both the water flow run-on time and the sensor range between the spout and the user’s hands are fully adjustable. • The spouts automatically switch off after 60 seconds of continuous flow, preventing any water wastage if there is attempted vandalism. • To prevent the potential build up of stagnant water, which can create legionella bacteria growth, the spout incorporates a hygiene rinse option which operates 12 hours after the last use of the spout. • Additional spout lengths are available. Please contact Cistermiser directly for further information. infrared taps and spouts 55 novatap vectatap (due summer 2013) novaspout vectaspout OURPRODUCTS
  • 56. 56 Tap option Wet hands Soap Hands Rinse Total Total Example Water (5 secs) (10 secs) (20 secs) seconds litres consumption Savings per year per year Conventional one handed lever mixer 35 7.58 415,005 – Self-closing non-concussive tap 7ltr/min 30 3.75 205,313 50.5% Novatap 5 ltr/min flow 25 2.08 113,880 72.6% Novatap 3.5 ltr/min flow 25 1.46 79,844 80.8% reducing water wastage On average, basin spouts deliver 8 litres of water per minute (BMA). Installing Cistermiser 3.5 litre per minute spouts can save up to 6 litres per use, saving over 80% during a 12 month period.
  • 57. installing a novatap, novaspout and vectaspout specification wording novatap, novaspout, vectatap and vectaspout – 5 and 3.5 litres per minute The mechanical contractor shall supply and install hands free, infrared activated deck-mounted (novatap, vectatap) or panel-mounted (novaspout) to all wash hand basin outlets. The units shall be for single water supply; either cold or temperature controlled hot water and will incorporate a pressure compensated flow regulator. The unit will be programmable for sensing range and run-on duration. The unit will also have a periodic hygiene rinse function to minimize bacterial infection such as legionella and have a cleaner’s function for routine janitorial servicing. The touch free basin spout is to be suitable for connection to either 230V 50Hz AC single phase supply or from 4 x 1.5V alkaline batteries of type LR6. For multiple product installations the device is to have the option of being installed with a common power supply unit PSUC capable of powering several units from one 230V fused spur. novatap, vectatap, novaspout and vectaspout – 5 litres per minute A flow of 5 litres per minute for compliance with BREEAM WAT1. novatap, vectatap, novaspout and vectaspout – 3.5 litres per minute (BREEAM Healthcare WAT4 compliant) A flow of 3.5 litres per minute for compliance with BREEAM WAT4 for use with open waste basins in healthcare applications. The unit should be the novatap, vectatap, novaspout or vectaspout as manufactured by: Cistermiser Limited Unit 1, Woodley Park Estate, 59 – 69 Reading Road, Woodley, Reading, RG5 3AN Tel: 0118 969 1611 product codes novatap 5 litres per minute: NT novatap 3.5 litres per minute: NT/3.5L novaspout 5 litres per minute: NS/L5 vectaspout 5 litres per minute: VS/L5 vectatap - due summer 2013 - contact us for details technical information 3.5 litres per minute The Water Regulations require that the flow rate of a tap does not exceed 3.6 litres per minute where basins have no plug. The Cistermiser spouts, with a 3.5 litres per minute limit ensures compliance in such applications. This model of flow restrictor is non-aerated and thus suitable for high risk applications such as medical facilities and care homes where the risk to users of legionella and other water-carried respiratory contracted viruses/bacteria is high. aerators /nozzles novatap and novaspout 5 litres per minute are supplied with a high tech Neoperl® Caché´® Perlator® Honeycomb aerator as standard. novatap and novaspout 3.5 litres per minute are supplied with a Neoperl® Caché´® Perlator® Honeycomb laminar nozzle. • Spray aerators are particularly suitable for low flow conditions and reducing water consumption in public areas. • Non-aerated non-splashing laminar stream. • Pressure compensating flow limited to 3.5 litres per minute. • External battery pack or transformer mounted below deck. • Unique single piece outlet design inhibits limescale build-up. • Integral anti-clogging dome screen filters sediment particles. • Patented design provides well aerated, soft to touch splash-free stream. • Pressure compensating flow limited to 5 litres per minute. 140mm 80mm Basin spout length 209mm 45mm204mm 37mm27mm 48mm 48mm 26.5 mm infrared taps and spouts 57 200mm 15mm 51mm • The novatap, novaspout and vectaspout can be powered by either mains or batteries, with both options included as standard. • Also available is a multi product power supply unit (PSUC) which provides power for up to 20 taps (Only 1 fused spur required). • Additional customised settings are obtainable via a hand held remote control Infrared Configuration Unit (ICU), which is available as an optional extra. The remote controller enables rapid automatic configuration to the specific washroom dimensions and deactivation of the hygiene rinse function. OURPRODUCTS
  • 58. anti-vandal taps showers vandal-resistant touch controlled water delivery to washroom taps and showers Our anti-vandal taps and showers are part of the Cistermiser anti-vandal range, a specialist vandal-resistant, touch-activated washroom control package for use in high risk or demanding public environments such as prisons, secure hospitals, schools and sports facilities. how it works The user interface is a stainless steel encased piezo touch button which is fixed flush with the mounting surface. When touched, the button causes an electronically operated valve to open and allow water to flow from a hand basin spout or shower head. The flow duration for each outlet is programmed on installation. If the user touches the button for a second time within the programmed flow period, water flow is stopped at once. There are no moving parts within the piezo touch button. The buttons are hard-wired to the AV six channel controller, which controls the outlets. Each unit can control up to six valves and each piezo touch button controls one outlet. product information • Touch buttons, basin spouts and shower heads are made from robust AISI 316L stainless steel. They come with anti-rotation washers and pins to ensure they cannot be removed or tampered with and used for self-harm or to inflict harm on others. There is a range of specially contoured anti- ligature versions of the shower and basin outlets for use in locations where self-harm is a real concern. • The highly versatile av range includes a piezo touch button, three styles of shower head, two styles of wall mounted basin spout, a WC cistern combined flushing and filling (drop and inlet) valve, a direct flushing urinal valve, a six channel controller and a power supply unit. • Touch buttons, shower heads and basin outlets are available in a choice of three tail lengths to accommodate panel/wall thicknesses from 17mm to 330mm. The piezo touch button is supplied with 3 metres of cable to allow maximum flexibility for sitting of the valves and control box. • System users only have access to touch buttons, shower heads and basin spouts. All other system components such as solenoid valves, six channel controllers, WC cisterns and water supply pipes are located in services voids, which are inaccessible to the users. • Programmable (adjustable) flow duration • AISI 316L stainless steel for maximum vandal protection • Ligature-resistant outlet heads and touch button • Low voltage operation from power supply with battery back-up • Robust piezo touch button • 12-hour hygiene rinse option • Anti-flood feature • Master control remote disable function • BREEAM WAT 1 compatible product 58
  • 59. total washroom control systems 59 total washroom control systems anti-vandal range valve sensazone 0118 969 1611 | sales@cistermiser.co.uk | www.cistermiser.co.uk OURPRODUCTS
  • 60. • Programmable (adjustable) flow duration • AISI 316L stainless steel for maximum vandal protection • Ligature-resistant outlet heads and touch button • Low voltage operation from power supply with battery back-up • Robust piezo touch button • 12-hour hygiene rinse option • Anti-flood feature • Master control remote disable function vandal-resistant touch-controlled water delivery to washrooms anti-vandal range valve touch activated washroom water control with no moving parts Cistermiser’s anti-vandal range is a specialist vandal-resistant range of touch- activated washroom controls for use in high risk or demanding public environments such as prisons, secure hospitals, schools and sports facilities. product information • Touch buttons, basin spouts and shower heads are made from robust AISI 316L stainless steel. They come with anti-rotation washers and pins to ensure they cannot be removed or tampered with and used for self-harm or to inflict harm on others. There is a range of specially contoured anti- ligature versions of the shower and basin outlets for use in locations where self-harm is a real concern. • The highly versatile anti-vandal range includes a piezo touch button, three styles of shower head, two styles of wall mounted basin spout, a WC cistern combined flushing and filling (drop and inlet) valve, a direct flushing urinal valve, a six channel controller and a power supply unit. • Touch buttons, shower heads and basin outlets are available in a choice of three tail lengths to accommodate panel/wall thicknesses from 17mm to 330mm. The piezo touch button is supplied with 3 metres of cable to allow maximum flexibility for sitting of the valves and control box. • System users only have access to touch buttons, shower heads, basin spouts, urinals and WC bowls. All other system components such as solenoid valves, six channel controllers, WC cisterns and water supply pipes are located in services voids, which are inaccessible to the users. 60