This document lists and describes 12 assistive products including toilet chairs, toilet seats, slip sleeves, stands for blankets, anti-decubitus cushions, boards for moving, and patient transfer belts. For each item, the document provides technical specifications, standards compliance, warranty information, and anticipated delivery time from contract signing.
Taber abrasion tester mainly through the rotation of the grinding method, use different types of friction wheel for rotating on the sample to detect leather and plastic materials wear resistance performance.
PPS UK are exclusive distributors of Flexco products in West Africa - Process & Plant Sales Limited Tel: +44 1902 495 913 Email: james.wood@processandplant.co.uk
Ghana, Mali, Cote D'Ivoire, Burkina Faso, Mauritania, Senegal, Liberia, Togo, Sierra Leone etc.
Taber abrasion tester mainly through the rotation of the grinding method, use different types of friction wheel for rotating on the sample to detect leather and plastic materials wear resistance performance.
PPS UK are exclusive distributors of Flexco products in West Africa - Process & Plant Sales Limited Tel: +44 1902 495 913 Email: james.wood@processandplant.co.uk
Ghana, Mali, Cote D'Ivoire, Burkina Faso, Mauritania, Senegal, Liberia, Togo, Sierra Leone etc.
Cytotoxic Safety Cabinet comes with Safety Height 200 mm (8 inches) of test opening, 440 mm (17 inches) of maximum opening, 465 m3/h (273 cfm) of exhaust volume
and 0.73m3 of internal work area. Maintaining cleanliness within the work zone for patient safety and product cleanliness. Provide highest level of operator
safety to protect the user’s personnel from hazardous compounds used in cytotoxic drugs. Incorporated with an advanced range of additional safety features.
Spacious knee room is provided for the operator in a sitting position, ensuring comfort during use.
MXD-01 Coefficient of Friction Tester can be used for static and kinetic coefficient of friction tests to plastic films, sheets, rubber, paper, PP woven bags, fabric (fabric styles test), metal-plastic composite strip/belt for communication cable, conveyor belt, wood, coating, brake pads, windshield wiper, shoe material, and tires and etc. With the material smoothness testing, users can control and adjust material quality technical indexes to meet application demands.
Power: 3.6V high performance lithium battery
Size (H x W x L): 60mm x 70mm x 60mm (2.36in. x 2.75in. x 1.96in.)
Net weight: 250g (0.55 lbs.)
Battery life: Up to 5 years (replaceable)
Engineering Design BMCG3313
Subject Lecturer : Dr Mohd Nizam Bin Sudin
Group Supervisor : Ts. Dr. Mohd Hafidzal bin Mohd Hanafi
Group Members:
1. Muhammad Zakwan bin Mohd Zamri
2. Eilias Aiman bin Aripin
3. Mohamad Yusri Izani bin Md Isa
4. Hijrah Safwan bin Safani
Mr Gurudas Aras, Director, A.T.E. Enterprises made a presentation on "Technological advancements in technical textiles" at the inaugural session of the Techtextil International Conference, Mumbai on 21 November 2019. The presentation mainly focused on the most relevant technological developments in technical textiles in the Indian context today and covered 'sustainability', 'durability', and 'functionality' aspects of the business. The presentation covered products like flushable and bio-degradable wipes, textile reinforced concrete, thermoplastic UD tapes for automobiles and coating and lamination for special applications respectively. Click here to view the presentation.
W3/230 is based on the infrared sensor method and designed for the determination of water vapor transmission rate of film and package specimens. It is applicable to various materials with high, medium and low water vapor permeability.
The long-stroke screener is the gentle giant of bulk material screening. It provides high separation sharpness and throughput without damaging fragile materials.
Universal abrasion resistant Tester can be used to flat grinding, mill grinding, edge grinding, folding grinding and anti-frost, edge-close and fleece and other wear-resistant test, can be used for woven fabrics, knitted fabrics, coated fabrics, fleece fabrics, socks, knitted fabrics, knitted fabrics, felt, nonwoven, deep fabric, yarn, cord plastic film, rubber, leather, paper, and many other materials.
Cytotoxic Safety Cabinet comes with Safety Height 200 mm (8 inches) of test opening, 440 mm (17 inches) of maximum opening, 465 m3/h (273 cfm) of exhaust volume
and 0.73m3 of internal work area. Maintaining cleanliness within the work zone for patient safety and product cleanliness. Provide highest level of operator
safety to protect the user’s personnel from hazardous compounds used in cytotoxic drugs. Incorporated with an advanced range of additional safety features.
Spacious knee room is provided for the operator in a sitting position, ensuring comfort during use.
MXD-01 Coefficient of Friction Tester can be used for static and kinetic coefficient of friction tests to plastic films, sheets, rubber, paper, PP woven bags, fabric (fabric styles test), metal-plastic composite strip/belt for communication cable, conveyor belt, wood, coating, brake pads, windshield wiper, shoe material, and tires and etc. With the material smoothness testing, users can control and adjust material quality technical indexes to meet application demands.
Power: 3.6V high performance lithium battery
Size (H x W x L): 60mm x 70mm x 60mm (2.36in. x 2.75in. x 1.96in.)
Net weight: 250g (0.55 lbs.)
Battery life: Up to 5 years (replaceable)
Engineering Design BMCG3313
Subject Lecturer : Dr Mohd Nizam Bin Sudin
Group Supervisor : Ts. Dr. Mohd Hafidzal bin Mohd Hanafi
Group Members:
1. Muhammad Zakwan bin Mohd Zamri
2. Eilias Aiman bin Aripin
3. Mohamad Yusri Izani bin Md Isa
4. Hijrah Safwan bin Safani
Mr Gurudas Aras, Director, A.T.E. Enterprises made a presentation on "Technological advancements in technical textiles" at the inaugural session of the Techtextil International Conference, Mumbai on 21 November 2019. The presentation mainly focused on the most relevant technological developments in technical textiles in the Indian context today and covered 'sustainability', 'durability', and 'functionality' aspects of the business. The presentation covered products like flushable and bio-degradable wipes, textile reinforced concrete, thermoplastic UD tapes for automobiles and coating and lamination for special applications respectively. Click here to view the presentation.
W3/230 is based on the infrared sensor method and designed for the determination of water vapor transmission rate of film and package specimens. It is applicable to various materials with high, medium and low water vapor permeability.
The long-stroke screener is the gentle giant of bulk material screening. It provides high separation sharpness and throughput without damaging fragile materials.
Universal abrasion resistant Tester can be used to flat grinding, mill grinding, edge grinding, folding grinding and anti-frost, edge-close and fleece and other wear-resistant test, can be used for woven fabrics, knitted fabrics, coated fabrics, fleece fabrics, socks, knitted fabrics, knitted fabrics, felt, nonwoven, deep fabric, yarn, cord plastic film, rubber, leather, paper, and many other materials.
1. LOT 1
Name of the
equipment
Technical characteristics ISO Quantity, Units
Toilet chairs
Type - Folding
Maximum load, not less than kg - 120
Material - steel, durable plastic
Width, cm - 52 ± 2
Length, cm - 50 ± 2
Height, cm - from 65 to 75
Number of height adjustment levels, not less than 5 levels
Seat height, cm - from 40 to 50 ± 2
Seat width, cm - 37 ± 2
Seat depth, cm - 40±;
Can be equipped with wheels, at least two of which are swivel and
with a locking mechanism Product feature:
• Removable lid
• The seat and the bucket with the lid are made of
durable plastic that is easy to clean.
• The handrails are covered with a soft, non-slip polymer
material.
• The seat can be adjusted in height.
Assistive products for personal hygiene that support users -
Requirements and test methods
Warranty period for the equipment – 6 months
Delivery: up to 80 calendar days from the date of signing the
contract
ISO 17966:2016 20
Toilet seat
The seat is made of plastic that can be treated with disinfectants.
Seat height (cm) not less than 10 and not more than 14 cm
Seat depth (cm) 41± 1
Maximum load (kg), not less than 110
Width between armrests (cm) 44±1 cm
Seat width (cm) 44±1
The seat shall be equipped with removable metal handrails
Assistive products for personal hygiene that support users -
Requirements and test methods
Warranty period for the equipment – 6 months
Delivery: up to 80 calendar days from the date of signing the
contract
ISO 17966:2016
40
Slip sleeve
Reusable tubular slip sleeve, size 150 cm x 110 cm ± 5 cm, made of
resistant, durable material with a high slip coefficient suitable for
use with decontamination solutions
Compliance with standards: EN 12182 Assistive products for
persons with disability - General requirements and test methods;
Compliance with standards: Council Directive 93/42/EEC of 14 June
1993 concerning medical devices
Warranty period for the equipment – 6 months
Delivery: up to 80 calendar days from the date of signing the
contract
Council Directive
93/42/EEC
17
Stand for a blanket
Stand for a blanket: takes the weight of the blanket from the user's
body to itself, can be used with any functional bed, lifts the blanket
off the legs and feet for comfort, located at the end of the bed so
as not to interfere, dimensions (WxDxH): 32 x 53 x 35 ±3cm.
Compliance with standards: EN 12182 Assistive products for
persons with disability - General requirements and test methods;
Compliance with standards: Council Directive 93/42/EEC of 14 June
1993 concerning medical devices
Warranty period for the equipment – 6 months
Delivery: up to 80 calendar days from the date of signing the
contract
Council Directive
93/42/EEC
11
Anti-decubitus cushion
Anti-decubitus cushion for use in cases of pressure ulcers: Cushion
made of memory foam for use in case of pressure ulcers, consisting
of a high density base, a central foam layer and a serrated top
made of memory gel foam.The cover is machine washable.
Dimensions 43±3*43±3*6±2 cm.
Compliance with standards: ISO 16840–1:2006 Wheelchair Seating –
Part 1: Vocabulary, Reference Axis Convention and Measures for
ISO 16840–1:2006
12
2. Body Segments, Posture and Postural-Support Surfaces ISO 16840–
2:2018 Wheelchair Seating – Part 2: Determination of Physical and
Mechanical Characteristics of Seat Cushions Intended to Manage
Tissue Integrity ISO 16840–3:2014 Wheelchair Seating – Part 3:
Determination of Static, Impact and Repetitive Load Strengths for
PSDs ISO 16840–6:2015 Wheelchair Seating – Part 6: Simulated Use
and Determination of the Changes in Properties of Seat Cushions
ISO/TR 16840–9:2015 Wheelchair Seating – Part 9: Clinical Interface
Pressure Mapping Guidelines for Seating ISO 16840–10:2014
Wheelchairs Seating – Part 10: Resistance to Ignition of Non-
integrated Seat and Back Support Cushions – Requirements and
Test Methods ISO/TS 16840–11:2014 Wheelchair Seating – Part 11:
Determination of Perspiration Dissipation Characteristics of Seat
Cushions Intended to Manage Tissue Integrity ISO/TS 16840–
12:2015 Wheelchair Seating – Part 12: Apparatus and Method for
Cushion Envelopment Testing
Warranty period for the equipment – 6 months
Delivery: up to 80 calendar days from the date of signing the
contract
Board for moving
Board for moving for the wheelchair, made of high-quality ABS
plastic, dimensions: 80 cm x 21 cm x 2.5 cm, (permissible negative
and positive deviation of the overall dimensions for length and
width is 10 cm, for thickness -1 cm), load capacity: at least 120 kg,
high tensile strength and ductility to prevent breakage
Compliance with standards: Council Directive 93/42/EEC of 14 June
1993 concerning medical devices/ Technical Regulation on medical
devices, approved by the Cabinet of Ministers of Ukraine on 2
October 2013, No. 753
Warranty period for the equipment – 6 months
Delivery: up to 80 calendar days from the date of signing the
contract
Council Directive
93/42/EEC
23
Patient transfer belt,
reinforced
Patient transfer belt (reinforced handles): 4 vertical handles on the
front; 2 horizontal handles on the sides; reinforced seams on the
handles; handles reinforced with soft plastic wrap for comfort for
the caregiver; outer outer layer of the belt is 100% polyester with a
dirt-repellent coating; dimensions (min. and max:) 78-130 ± 5 cm.
Compliance with standards: Council Directive 93/42/EEC of 14 June
1993 concerning medical devices/ Technical Regulation on medical
devices, approved by the Cabinet of Ministers of Ukraine on 2
October 2013, No. 753
Warranty period for the equipment – 6 months
Delivery: up to 80 calendar days from the date of signing the
contract