3. Carbonators
Code: 060072
Fitting for inlet water carbonator 1/4" F. - 5/16" Q.F.
Code: 060073
Fitting for inlet Co2 carbonator 1/4" F. - 5/16" Q.F.
Code: 060074
304 SS water carbonator 1,2lt. 5/16" OD stem with fittings 1/4"F.
This product is planned for the production of sparkling water using exclusively carbon dioxide up to the
maximum pressure of 7 bar with potable water.
Technical features:
- Level control with one probe
- Ground Faston
- Two single check valves on inlet water
- Two single check valves on inlet co2 Gas
- Water inlet thread 1/4” gas
- Gas inlet thread 1/4” gas
- Output probe fitting connection 8mm(5/16”)
13 October 2017 3/39
4. - Bottom drain with cap
- Max. operating pressure = 7bar(101psi)
- Bursting pressure = 80bar(1.160psi)
- Safety valve relief pressure = 8,5bar(123psi)
- Max. volume = 1,2lt.
- Min. volume = 0,9lt.
- Carbonator max. capacity = 3lt./min 11bar(159psi) h2o, pump 300lt./h., 4bar(58psi) Co2.
Code: 060079
316 SS water carbonator from 0,250lt. to 1,27lt. 1/8" F.
Features
Misures Ø x H - 0,250lt.(mm): 90x100
Misures Ø x H - 0,510lt.(mm): 90x140
Misures Ø x H - 0,760lt.(mm): 90x180
Misures Ø x H - 1,020lt.(mm): 90x220
Misures Ø x H - 1,270lt.(mm): 90x260
Variants
Code Description
060079-001 316 SS water carbonator from 0,250lt. - vertical
060079-002 316 SS water carbonator from 0,510lt. - vertical
060079-003 316 SS water carbonator from 0,760lt. - vertical
060079-004 316 SS water carbonator from 1,020lt. - vertical
060079-005 316 SS water carbonator from 1,270lt. - vertical
060079-010 316 SS water carbonator from 0,250lt. - horizontal
060079-011 316 SS water carbonator from 0,510lt. - horizontal
060079-012 316 SS water carbonator from 0,760lt. - horizontal
060079-013 316 SS water carbonator from 1,020lt. - horizontal
060079-014 316 SS water carbonator from 1,270lt. - horizontal
Technical features:
- Level control with double probe
- Made of stainless steel AISI 316
- Antibacterial silver welds
- Horizontal or vertical functioning
- Both internal and external pickling (metal)
- Water inlet thread 1/8” gas
- Water outlet thread 1/8” gas
- Gas inlet thread 1/8” gas
- Max. operating pressure = 8,5 bar (123 psi)
- Bursting pressure = > 20 bar (290 psi)
- Carbonator max. capacity = 2lt./min 12bar(732psi) h2o, pump 300lt./h., 4bar(58psi) Co2.
Pickling is a metal surface treatment used to remove impurities, such as stains, inorganic contaminants,
rust or scale from ferrous metals, copper, precious metals and aluminum alloys. A solution called pickle
liquor, which contains strong acids, is used to remove the surface impurities. It is commonly used to
descale or clean steel in various steelmaking processes.
NOTA BENE:
The use of a control valve is recommended for the installation of a tube for sparkling water bigger than
13 October 2017 4/39
5. 4mm or 5/32''.
In this mode the sparkling water will not have a metal taste.
Solenoid valves
Code: 060001
Auto-Flushing Valve 24VDC 1/4" NPT - 400 ML
Code: 060002
Solenoid valve 24VDC NC female 1/4" FTP w/filtering mesh
Code: 060004
Floating Valve , Mechanical Style , Tube 1/4"
13 October 2017 5/39
6. Code: 060005
Floating , Micro-Switch , 10 Ampere
Code: 060008
Solenoid valve at one way 220V-AC / 24V-DC / 24V-AC
Variants
Code Description
060008-01 Solenoid valve at one way Voltage 220-AC
060008-02 Solenoid valve at one way Voltage 24V-DC
060008-03 Solenoid valve at one way Voltage 24V-AC
1-way solenoide valve with body in food grade resin membrane in platinic silicone 3/4" X 1/4"
Flow rate: 2,5 Lt/Min - 2,5 bar
Nominal pressure: 10 bar
Code: 060077
One way flowmeter solenoid valve 220V~240V - 50/60Hz 6VA
N.C.
Features
Ambient temperature: 2 °C ÷ 60 °C
Temperature of fluid: 2 °C ÷ 70 °C
Operating pressure: 0.02 ÷ 1 MPa (0.2 ÷ 10 bar)
Flow rate: According to the mounted regulator (2.5 to 8 l/min)
Minimum flow of signal presence: 0.6 l/min
13 October 2017 6/39
7. Minimum flow of flow rate measure: According to the flow regulator used
Accuracy of the flow measure: According to the flow rate (+/-4.5% to +/-8%)
Hall sensor power supply: 3.8 – 24 Vdc
Resistance to Bursting: > 6 MPa ( > 60 bar ) a 25°C
Life: 50.000 cycles - 200.000 total litres
Variants
Code Description
060077-01 One way flowmeter solenoid valve 220V~240V - 50/60Hz 6VA N.C.
060077-02 One way flowmeter solenoid valve bracket
060077-03 Flowmeter solenoid cable
Servo-assisted solenoid valve for water with integrated flow sensor. This valve is typically used on
household appliances connected to the hydraulic network. A flow sensor, capable of measuring the volume
of delivered water, and a flow limiter, capable of limiting the value of the water flow rate, as a function of
inlet pressure, are integrated to the valve. The flow sensor is constituted by an impeller immersed in the
water flow. The impeller rotation cause the ferrite magnets to rotate in front of a hall effect sensor. The
obtained signal is a square wave with the pulse frequency proportional to the flow of water.
Features:
* Water inlet with 3/4 inch BSP thread for EU applications and 3/4 inch GH for U.S. applications.
* Water output with connection for rubber hoses - 10/12 mm.
* Coil electrical connections with 6.3x0.8mm terminals and rast connectors 2.5 (IP00).
* Electrical connections of the flow sensor of type rast 2.5.
* The sensor is protected by double insulation, and therefore is suitable for use even on applications that
are not equipped with safety transformers SELV.
Code: 060038
3 ways solenoid valve 1/8" F. 230V - 50Hz - TA:80°C - P:0/18bar
Normally Closed (NC).
Code: 060011
Solenoid valve 24V-DC / 24V-AC 1/4" FPT - N.C.
Variants
Code Description
060011-01 Solenoid valve 24V-DC / 24V-AC 1/4" FPT - N.C.
13 October 2017 7/39
8. 060011-02 Solenoid valve 24V-AC 1/4" FPT - N.C
Normally closed.
Code: 060009
Solenoid valve at one way 220V quick fitting 1/4''
1-way solenoide valve with body in food grade resin membrane in platinic silicone 3/4" X 1/4" quick fitting.
Flow rate: 2,5 Lt/Min - 2,5 bar
Nominal pressure: 10 bar
Voltage: 220V - AC
Code: 060010
Solenoid valve at 2 ways 220V-AC
2-ways solenoide valve with body in food grade resin membrane in platinic silicone 3/4" x 1/4"
Voltage: 220V - AC
Code: 060007
Solenoide valve 3 entrances - 1 OutPut 220V / 24V
Variants
Code Description
060007-01 Solenoide valve 3 entrances - 1 OutPut Voltage 220V-AC
060007-02 Solenoide valve 3 entrances - 1 OutPut Voltage 24V-DC
13 October 2017 8/39
9. 3-ways solenoide valve, with body in food grade resin and membrane in platinic silicone 3/4" x 1/4".
Flow rate: 6,7 Lt/Min - 3,5 bar
Nominal pressure: 10 bar
Voltage: 220V - AC
Voltage: 24V - DC
Flow Restrictors
Code: 060034
Flow Restrictor, Female 1/4'' 300cc, 400cc , 550cc , 600, 800cc
Variants
Code Description
060034-01 Flow Restrictor, Female 1/4'' 300cc (LAST PIECES)
060034-02 Flow Restrictor, Female 1/4'' 400cc (LAST PIECES)
060034-03 Flow Restrictor, Female 1/4'' 550cc (LAST PIECES)
060034-05 Flow Restrictor, Female 1/4'' 800cc
Code: 060035
Flow Restrictor, Female or Quick Fit 1/4", 300cc, 350cc, 400cc,
420cc, 550cc
Variants
Code Description
060035-01 Flow Restrictor, Female 1/4" 300cc
060035-02 Flow Restrictor, Female 1/4" 350cc
060035-03 Flow Restrictor, Female 1/4" 400cc
060035-04 Flow Restrictor, Female 1/4" 420cc
060035-05 Flow Restrictor, Female 1/4" 550cc
060035-07 Flow Restrictor, Quick fit 1/4" 300cc
060035-08 Flow Restrictor, Quick fit 1/4" 350cc
060035-09 Flow Restrictor, Quick fit 1/4" 400cc
060035-10 Flow Restrictor, Quick fit 1/4" 420cc
060035-11 Flow Restrictor, Quick fit 1/4" 550cc
13 October 2017 9/39
11. Pressure: 0 - 10 bar
Code: 060075
Dry pressure gauge for board installation 1/8" (Ø 40mm)
Dry plastic case DN40 Rear connection for panel mount with screwed flange.
Pressure: 0-16bar(0-230psi)
Materials
Case: Black plastic
Dashboard flange: Chromed plastic
Trasparent: Clear plastic
Quadrant: White plastic
Index: Black plastic
Fitting: Brass side hexagon 14mm
Manometer: Bourdon copper alloy spring, solder alloy of tin, c. spring
Movement: Patent brass/polyester
Technical features
Reference regulations: EN 837-1
Working pressure:
Static: 75% of full scale value
Floating: 60% of full scale value
For short periods: up to full scale value
Temperature limits:
Environment: -20 ... +60°C
Fluid: +60°C max
Storage: -20 ... +60 °C
Temperature drift: ±0,04%/1K compared to (+20°C)
Accuracy class: cl. 2.5, cl. 1.6 on request
Level of protection: IP 43 per EN 60 529/IEC 529
13 October 2017 11/39
12. Engine vane pumps
Code: 060059
Engine water cooled rotary pump for reverse osmosis 180W.
Code: 060060
Air fan cooled rotary pump engine for reverse osmosis 180W.
Air cooled 180W engine for reverse osmosis rotary pump. Capacitor included.
* Specifications: 230VAC - 1,65AMP (7µF)
* Frequency: 50Hz
* Power: 180W
* Motor Rotation: 1400 RPM
Code: 060084
Air cooled rotary pump engine for reverse osmosis 180W.
Air cooled 180W engine for reverse osmosis rotary pump. Capacitor included.
* Specifications: 230VAC - 1,65AMP (7µF)
* Frequency: 50Hz
* Power: 180W
* Motor Rotation: 1400 RPM
13 October 2017 12/39
13. Vane pumps
Code: 060041
Fluid o Tech Brass vane pumps for revers osmosis
200-300-400-600-800-1000 lt/h
Variants
Code Description
060041-01 PA204 Fluid o Tech Brass vane pumps 200 lt/h with by-pass (12)
060041-02 PA200 Fluid o Tech Brass vane pumps 200 lt/h without by-pass (12)
060041-03 PA304 Fluid o Tech Brass vane pumps 300 lt/h with by-pass (12)
060041-04 PA300 Fluid o Tech Brass vane pumps 300 lt/h without by-pass (12)
060041-05 PA404 Fluid o Tech Brass vane pumps 400 lt/h with by-pass (12)
060041-06 PA400 Fluid o Tech Brass vane pumps 400 lt/h without by-pass (12)
060041-07 PA601 Fluid o Tech Brass vane pumps 600 lt/h with by-pass (6)
060041-08 PA600 Fluid o Tech Brass vane pumps 600 lt/h without by-pass (6)
060041-09 PA801 Fluid o Tech Brass vane pumps 800 lt/h with by-pass (6)
060041-10 PA800 Fluid o Tech Brass vane pumps 800 lt/h without by-pass (6)
060041-11 PA1001 Fluid o Tech Brass vane pumps 1.000 lt/h with by-pass (6)
060041-12 PA1000 Fluid o Tech Brass vane pumps 1.000 lt/h without by-pass (6)<br />
The rotary vane pumps, manufactured by Fluid-o-Tech and sold worldwide under the trademark Rotoflow,
are volumetric pumps designed for pumping water and moderate aggressive liquids with low flow at high
pressure.
Technical features and manufacturing characteristics
The rotary vane pump is brass made with a stainless steel AISI 303 rotor, while the pumping chamber and
the vanes are in carbon graphite.
The inlet and outlet ports are 3/8" GAS or NPT threaded.
The pumps are designed to be directly mounted to the motor with a stainless steel clamp.
For different mounting arrangements see our technical info “optional mountings”.
Maximum operative temperature: 70 °C (158 °F).
Available upon request:
- Viton®/EPDM seals (suffix - V/E)
- built-in relief valve
- built-in 70 mesh filter
- flange mount
Main applications
- Beverage vending machines
- Post-mix drink dispensers
- Espresso coffee machines
- Cooling systems
- Reverse osmosis
- Ultra-filtration
- Water dispensers
13 October 2017 13/39
14. Code: 060042
Fluid o Tech AISI 303 stainless steel vane pumps for reverse
osmosis 300-400-600-800-1000 lt/h
Variants
Code Description
060042-01 PA310 Fluid o Tech 303 stainless steel vane pumps 300 lt/h with out by-pass (12)
060042-02 PA311 Fluid o Tech 303 stainless steel vane pumps 300 lt/h with by-pass (12)
060042-03 PA410 Fluid o Tech 303 stainless steel vane pumps - 400 lt/h with out by-pass (12)
060042-04 PA411 Fluid o Tech 303 stainless steel vane pumps - 400 lt/h con by-pass (12)
060042-05 PA610 Fluid o Tech 303 stainless steel vane pumps - 600 lt/h senza by-pass (6)
060042-06 PA810 Fluid o Tech 303 stainless steel vane pumps - 800 lt/h with out by-pass (6)
060042-07 PA1010 Fluid o Tech 303 stainless steel vane pumps - 1.000 lt/h with out by-pass (6)
The rotary vane pumps, manufactured by Fluid-o-Tech and sold worldwide under the trademark Rotoflow,
are volumetric pumps designed for pumping water and aggressive liquids with low flow at high pressure.
Technical features and manufacturing characteristics
The housing and the rotor are in stainless steel AISI 303, while the pumping chamber and the vanes are in
graphitic carbon.
Inlet and outlet ports are 3/8" GAS or NPT threaded.
A built-in adjustable bypass to protect the pump and the system from unexpected pressure spikes is also
available upon request.
The pump can be connected to direct coupling motors with a stainless steel clamp or to M71 and M80
UNELMEC or NEMA 56C frame motors with the Fluid-o-Tech coupling and adapter set.
Maximum operative temperature: 70 °C (158 °F).
Available upon request:
* Viton®/EPDM seals (suffix - V/E)
Main applications
* Soda circulation in post-mix drink dispensers
* Cooling systems
* Reverse osmosis
* Ultra-filtration
* Booster systems
13 October 2017 14/39
15. Booster pumps
Code: 060043
Booster pump UP-7000/24VDC 220VAC/50Hz
Features
Size: 173x102x103 (mm)
Weight: 2kg
Voltage: 24 / 36 / 48 VCD
Rotation speed rate: 550~600rpm
Power Hertz: 50 / 60 Hz
Temperature Rating: 10 °C~45 °C
Voltage Insulating Test: 0.8 KV / 3 second (under 0.6 mA)
Power consumption: 24W 36W 48W
Max. outlet pressure: 120psi
Working pressure: 80psi
Flow rate @ 80 psi: 0.65 lpm / 1.24 lpm / 2.0 lpm
Variants
Code Description
060043-01 Booster pump UP-7000/24VDC 220VAC/50Hz w/transformer
060043-02 Booster pump UP-7000/24 AC24V without transformer
060043-03 Transformer 220V/24VDC 1.2A internal connection to the UP-7000
060043-04 Pump head for UP-7000
Code: 060044
Booster pump UP-8000/24, 36, 48 VDC 220VAC/50Hz
Features
Size UP-8000: 196x102x103 (mm)
Size UP-8000W: 196x102x105 (mm)
Weight UP-8000: 2,3kg
Weight UP-8000W: 2,3kg
Voltage UP-8000: 24 / 36 / 48 VCD
Voltage UP-8000W: 24 / 36 / 48 VCD
Rotation speed rate UP-8000: 1500rpm 50 rpm
Rotation speed rate UP-8000W: 1800rpm 50 rpm
Power Hertz UP-8000: 50 / 60 Hz
13 October 2017 15/39
16. Power Hertz UP-8000W: 50 / 60 Hz
Operation Temperature UP-8000: 10 °C~45 °C
Operation Temperature UP-8000W: 10 °C~45 °C
Voltage Insulating Test UP-8000: 0.8 KV / 3 second (under 0.6 mA)
Voltage Insulating Test UP-8000W: 0.8 KV / 3 second (under 0.6 mA)
Power consumption UP-8000: 57W 77W 90W
Power consumption UP-8000W: 57W 77W 90W
Max. outlet pressure UP-8000: 120psi
Max. outlet pressure UP-8000W: 120psi
Working pressure UP-8000: 80psi
Working pressure UP-8000W: 80psi
Flow rate @ 80 psi UP-8000: 1.9 lpm / 2.4 lpm / 3.1 lpm
Flow rate @ 80 psi UP-8000W: 1.9 lpm / 2.4 lpm / 3.1 lpm
Variants
Code Description
060044-03 Booster pump UP-8000/36VDC w/o transformer
060044-04 Booster pump UP-8000W/24 DC24V w/o trasformer water cooling ring
060044-05 Booster pump UP-8000/24 DC36V 220VAC/50Hz with transformer water cooling ring
060044-06 Transformer 220V/36VDC 2A for code 060044-03<br />
060044-07 Pump head for UP-8000
060044-08 Transformer 220V/24VDC 4A. for code 060044-04
060044-09 Booster pump UP-8000/48VDC 220VAC/50Hz with transformer
060044-10 Booster pump UP-8000/48VDC 220VAC/50Hz w/o transformer
060044-11 Transformer 220V/48VDC 2A for code 060044-09/10
* MOTOR: 36VDC
* INPUT: 220VAC/50Hz
* OUTPUT: DC36V/2A
* FLOW RATE: 3LPM
Code: 060055
Booster pump UP-8500W water cooling 220VAC/50-60Hz
Features
Size: 170x119x110 (mm)
Weight: 2,3kg
Voltage: 220 VCD
Rotation speed rate: 2100rpm 50 rpm
Power Hertz: 50 / 60 Hz
Temperature Rating: 10 °C~45 °C
Voltage Insulating Test: 0.8 KV / 3 second (under 0.6 mA)
Power consumption: 90W
Max. outlet pressure: 120psi
Working pressure: 80psi
Flow rate @ 80 psi: 3,9 lpm
Variants
Code Description
060055-01 Booster pump UP-8500W water cooling 220VAC/50-60Hz with P.C.B control box
060055-02 Booster pump UP-8500W water cooling 220VAC/50-60Hz with-out P.C.B control box
060055-03 Booster pump UP-8500W 220VAC/50-60Hz P.C.B control box
060055-04 UP-8500W replacement pump head
13 October 2017 16/39
17. * Top quality brushless pump for commercial RO system ( 150 - 300 GPD) and quiet operation.
* Longer lifespan and more durable performance.
* One hundred thousand recyling test under 0 to 150 psi.
* Self-priming ability : 3 meters.
* Cooling ring patent design maintains a cool operating temperature of the pump, effectively extending the
lifespan of the pump head.
* P.C.B control box included.
Code: 060066
Booster pump PSP220 220V (8)
Variants
Code Description
060066-01 PSP220 Booster pump 220V (8)
060066-02 PSP220 replacement pump head
060066-03 PSP220 Couple of carbon brush
220 volt PSP Booster Pump Without transformer. 28 cm. cable for terminal box connection.
* Max pressure: 70psi
* Specifications: 230VAC - 0,8AMP
* Flow rate: 5,2lt./min.
* Connections: 3/8" NPTF
* Pump head: In grivory also suitable for carbonation/soda systems water.
Code: 060087
Aquatec CDP 5800 220V. booster pump
Features
Power supply: 220/230V - 50/60Hz
Flow rate: 1,26 gpm (4,8L/min)
Ampere: 0,58 A @ 130psi (9bar)
Bypass: 9bar - 130psi
Power consumption: 110W
Max. inlet pressure: < 4bar
Max. outlet pressure: 11bar - 160psi
13 October 2017 17/39
19. Code: 060028
High Pressure Switch (20-40 psi) , Male Type 1/4'' Jaco
15 - 30 psi (1 psi = 0.07 bar) adjustable high-pressure switch for equipment with out pump.
Code: 060029
High Pressure Switch (20-40 psi) , Male Type 1/4'' Jaco
Code: 060030
High Pressure Switch (20-40 psi) , Type 1/4'' quick fitting
Code: 060071
High Pressure Switch (20-40 psi) , Type 1/4'' OD stem
13 October 2017 19/39
20. Code: 060076
High Pressure Switch (29-72,52 psi/2-5 bar) 1/4'' - 10A.
Factory Calibration: 36,26 psi (2,5 bar)
Sensors
Code: 060023
Single TDS Sensor Probes
* Stainless steel sensor
* Probe: 1/4"
* Cable: 45" (114,30 cm.)
* Connector: Single 4-pin
* Thermometer pin: Yes
* Sensors have a green wrap and no label
* Pressure Rating: 16bar @ +23°C
Code: 060024
In-line flow sensor
The FS-2000(H) flow sensor comes with a reed switch or Hall effect switch which delivers a switch signal or
digital signal to electronic control unit when it is activated by the magnetic force of the flow sensor turbine. It
13 October 2017 20/39
21. can detect water flow from 1.7 to 14.1 L /min.
The connection of the FS-2000(H) is 3/ 8” NPT female.
Its body and turbine are made of acetal copolymer (POM) material.
The best location to connect the FS-2000(H) is on the outlet channel of the filter.
Because it's sensitive to rust and dirt. It could be installed at vertical or horizontal position.
For most of residential water filters and coolers, the FS-2000(H) is an ideal flow measurement and control
solution for filter life or water dispensation monitor , it detects precisely, works reliable and is most
affordable. The FS-2000(H) is compatible with the PWA 608M , the electronic flow monitor control board
and the PWA608T, the electronic flow totalizer control board.
Switching Voltage : Max. 200 Volts
Switching Current : Max. 0.5 Amps
Carry Current : Max. 1.5 Amps
Switching Frequency : Max. 500 Hz
Contact Resistance : Max. 150 mO
Life Expectancy : 1 x 108 Ops
Mounting Method: Horizontal to Vertical
Flowing Direction: Bi-Direction
Flow Rate:
Maximum 3.72 gpm, 14.1 lpm (vertical and horizontal mounting)
Minimum 0.40 gpm, 1.50 lpm (horizontal mounting)
Minimum 0.26 gpm, 1.00 lpm (vertical mounting)
Calibration:
0.00106 gallon, 0.004 liter per pulse 0.00088 gallon, 0.0033 liter per pulse (vertical mounting)
Connection: 3/8 inch NPT Female
Temperature: 0 to 40? (32 to 104 ?)
Pressure: Max. 6.0 bar (85 psi)
Weight: 50g (1.92 oz.)
Accuracy: +/- 10%
Materials: Sensor Body : Acetal Copolymer, TICONA M90
Turbine: Acetal Copolymer, TICONA M90
Stick of Turbine: #304 Stainless Steel
O-Ring: E.P.D.M.
Code: 060057
TDS Sensor Probes for the RT-770, RT-790
For models: 060014 * 06015
13 October 2017 21/39
26. Diameter: 400mm. Height: 730mm. Connection: 3/4"M.
Code: 060052
1/4” F – 1/4” M plastic square
Anti leaking systems
Code: 060006
Anti leak water (sensor + electronic board)
Variants
Code Description
060006-01 Replacement Anti leak sensor 24, 36V.
060006-24 Anti leak water (sensor + electronic board) 24V.
060006-36 Anti leak water (sensor + electronic board) 36V.
System to stop the water in-let.
Sensor dipped in gold
Electronic dedicated PCB
Electrovalve Mod. 4030-ID00637 not included
Voltage: 24V or 36V
Code: 060053
Leaking sensor's PCB w/wiring complete set
13 October 2017 26/39
28. Code: 060090
IEC tripolar built-in plug bright switch with fuse
Code: 04704721
Fast fuse 250V - 5x20mm - 16A.
Code: 060070
IEC power supply cable - schuko EU plug
Variants
Code Description
060070-01 IEC power supply cable - schuko EU plug White
060070-02 IEC power supply cable - schuko EU plug Black
060070-03 EU power supply cable Female IEC 90° plug - 90° schuko EU plug White
060070-04 EU power supply cable Female IEC 90° plug - 90° schuko EU plug Black
Cable: 2mt. (3x0,75mm.)
13 October 2017 28/39
29. Code: 060088
IEC power supply cable - L type plug (Italian 3-plug)
Variants
Code Description
060088-01 EU power supply cable Female IEC 90° plug - Italian 3-plug L type Black
Cable: 2mt. (3x0,75mm.)
Water purity testers
Code: 060013
Electrolysis system for reverse osmosis test
Variants
Code Description
060013-01 Electrolysis 220 V.
060013-02 Electrolysis 220V. (Last pieces)
060013-04 Aluminium electrode replacement for 060013-02
060013-05 Iron electrode replacement for 060013-02
Code: 060014
RT-770 In-Line TDS Tester
13 October 2017 29/39
30. Variants
Code Description
060014-01 RT-770 In-Line TDS Tester AA batteries x 2 - 40ppm.
060014-02 RT-770 In-Line TDS Tester AA batteries x 2 - 80ppm.
060014-03 RT-770 In-Line TDS Tester AA batteries x 2- 100ppm.
060014-04 RT-770 In-Line TDS Tester AA batteries x 2- 150ppm.
060014-05 RT-770 In-Line TDS Tester 12-24V DC power connection - 40ppm.
060014-06 RT-770 In-Line TDS Tester 12-24V DC power connection - 80ppm.
060014-07 RT-770 In-Line TDS Tester 12-24V DC power connection - 100ppm.
060014-08 RT-770 In-Line TDS Tester 12-24V DC power connection - 150ppm.<br />
The RT-770 is an in-line and low cost testing device to monitor the quality of pure water which is generated
by Reverse Osmosis water filters. It measures the conductivity of water and convert it to be TDS reading.
The measured TDS reading is compared to the pre-setting TDS value.
The RT-770 turns on RED light if the measured TDS reading is over the pre-setting TDS value. If it’s under
the pre-setting TDS value, the RT-770 turns on Green light.
Alert options available: 40ppm - 80ppm - 100ppm - 150ppm.
Features:
One push-button testing
Internal battery power or external power
Easy connected to most of reverse osmosis water filters
Operating guide
1-Cut off the outlet tube(between tank of the reverse osmosis water filter and faucet).
2-Insert the tube into the quick fitting.
The probe needs to be cleaned every year to avoid scaling which may result into inaccuracy
testing.
Specification :
Dimension : 70mm(L) x 55m(W) x 33mm(D)
Weight : 80 g
Cable length : 45 cm.
Operating : 3000 operating times
Power : AA batteries x 2 or 3 – 24V DC
Code: 060015
RT-790, In-Line Programmable Automatic TDS Tester
The RT-790 is an in-line and low cost testing device to monitor the quality of pure water which is generated
by reverse osmosis water filters. It measures the conductivity of water and convert it to be TDS reading.
The measured TDS reading is compared to the pre-setting TDS value. The RT-790 turns on RED light if the
measured TDS reading is over the pre-setting TDS value. If it’s under the pre-setting TDS value, the
RT-790 turns on Green light.
Feature :
* Automatic testing or manual testing
* Internal battery power
13 October 2017 30/39
31. * Easy connected to most of reverse osmosis water filters
Connecting Fitting
Cut off the outlet tube (between tank of the reverse osmosis water filter and faucet). Insert the tube into the
quick fitting
Operating
Automatic testing:
a)Testing per hour.
b)If testing resistance value is bigger than setting resistance value, it isn’t displayed on LCD.
c)If testing resistance value is smaller than setting resistance value, it will be recorded. After five times
record, it will enter into warning status and stop testing.
Manual testing:
a)Press the button for testing.
b)If testing resistance value is bigger than setting resistance value, the blue light will flash five times and
enter into automatic testing model.
c)If testing resistance value is smaller than setting resistance value, after red light flashing and alarm
warning five times, it will enter into warning status and stop testing.
5.4 Reset Use stick to keep pressing the “RESET” button for 4 seconds or reset the batteries.
The probe needs to be cleaned every year to avoid scaling which may result into inaccuracy testing.
Specification :
* Dimension : 70mm(L) x 55m(W) x 33mm(D)
* Weight : 80g.
* Cable length : 45 cm.
* Operating : 3000 operating times
* Power : AA batteries x 2
* Operating current : 1 mA@3V DC
Code: 060016
Quick Check TDS/Conductivity Monitor
Press the "Push-to-Check" button for an instant water quality check!
FEATURES
* With the push of a button, the unit displays a green or red light, indicating good water quality or service
required, respectively.
* Tests for TDS or conductivity levels.
* Eight programmable set points (by dip switch).
* Bright LED lights.
* Simple to use.
* Factory Calibrated to 100 ppm NaCl. Re-calibration is unncessary.
* Comes equipped with Mur-lok® Quick-Connect T-fitting (1/4 inch standard, also available in 3/8" or 1/2" ).
* Excellent Reverse Osmosis (RO) or Deionization (DI) monitor.
* Installs quickly and easily.
13 October 2017 31/39
32. SPECIFICATIONS
TDS/EC Range: 0-5000 ppm (10,000 µS)
Max. Set Point: 50 ppm (100 µS)
Accuracy: ±3%
ATC: No
Cable Length: 24.5" (including sensor)
Fittings: 1/4"
Power source: 4 x 1.5V button cell batteries (included)
Battery life: Approx. one year
Size: 7.6 x 2 x 4.7 cm (3 x .8 x 1.9 in.)
Code: 060017
Quick Check TDS LCD Monitor
Ideal for any water filtration system, including reverse osmosis systems, coolers and much more.
FEATURES
* Displays TDS level of a single water line.
* Highly efficient and accurate due to its advanced microprocessor technology.
* Auto-Off function conserves battery power. The unit shuts off automatically after 10 minutes of non-use.
* Wide Range 0-9990 ppm (From 0 - 999 ppm the resolution is 1 ppm. From 1000 to 9990 ppm, the
resolution is 10 ppm, indicated by a blinking 'x10' image.)
* Factory Calibrated: our meters are calibrated with a 342 ppm NaCl solution. Meters can be recalibrated
with a mini-screwdriver.
* Comes equipped with Mur-lok® Quick-Connect T-fitting (1/4 inch standard, also available in 3/8" or 1/2" ).
* Installs quickly and easily.
SPECIFICATIONS
Range: 0-9990 ppm
Accuracy: ±2%
Conversion Factor: NaCl (avg. 0.5)
Cable Length: 24.5" (including sensor)
Fittings: 1/4" standard, also available with 3/8" or 1/2"
Power source: 2 x 1.5V button cell batteries (included)
Battery life: approx. 1000 hours of continuous use
Size: 7.6 x 2 x 4.7 cm (3 x .8 x 1.9 in.)
13 October 2017 32/39
33. Code: 060018
DM-1 In-Line Dual TDS Monitor
Measure the tap water coming in vs. the purified water going out of your water filtration system at any time.
FEATURES
* Displays TDS levels of the feed water and product water with in & out electrode probes.
* Highly efficient and accurate due to its advanced microprocessor technology.
* Auto-Off function conserves battery power. The unit shuts off automatically after 10 minutes of non-use.
* Dual Range 0-9990 ppm (From 0 - 999 ppm the resolution is 1 ppm. From 1000 to 9990 ppm, the
resolution is 10 ppm, indicated by a blinking 'x10' image.)
* Factory Calibrated: our meters are calibrated with a 342 ppm NaCl solution. Meters can be recalibrated
with a mini-screwdriver.
* Comes equipped with Mur-lok® Quick-Connect T-fittings.
* Installs quickly and easily.
SPECIFICATIONS
Range: 0-9990 ppm
Accuracy: ±2%
Conversion Factor: NaCl (avg. 0.5)
Cable Length: 24.5" (including sensor)
Fittings: 1/4" standard, also available with 3/8" or 1/2"
Power source: 2 x 1.5V button cell batteries (included)
Battery life: approx. 1000 hours of continuous use
Size: 7.6 x 2 x 4.7 cm (3 x .8 x 1.9 in.)
Code: 060019
Dual TDS Sensor Probes for the DM-1
* Stainless steel sensors
* Probe: 1/4"
* Cable: 24.5"
* Connector: 8-pin
* Thermometer pins: Yes
* Each sensor of the pair has a blue or red wrap and labeled "IN" or "OUT"
13 October 2017 33/39
34. * Pressure Rating: 16bar @ +23°C
Code: 060020
DM-2 Commercial/residential in-Line Dual TDS Monitor
Install on industrial systems such as car washes, window washing, manufacturing, and food processing.
FEATURES
* Highly efficient and accurate due to its advanced microprocessor technology.
* Displays TDS levels of the Feed Water and Product Water with in & out electrode probes.
* Auto-Off function conserves battery power. The unit shuts off automatically after 20 seconds.
* Dual Range - Measures from 0-999 ppm, with a resolution of 1 ppm. From 1000 to 9990 ppm, the
resolution is in 10 ppm increments, indicated by a blinking 'x10' image.
* Factory Calibrated: our meters are calibrated with a 342 ppm NaCl solution. Meters can be recalibrated
with a mini-screwdriver.
* Comes equipped with 1/4 inch Mur-lok® Quick-Connect T-fittings. Also available with 3/8" or 1/2" fittings.
* Installs quickly and easily.
Differences from the DM-1:
* Designed for commercial/industrial applications.
* Stronger, water-resistant casing.
* Calibration can be done individually or simultaneously on each line.
* Improved design, including an extra large, easy-to-read LCD display.
* Longer, waterproof, shielded cables.
* Variable mounting bracket.
SPECIFICATIONS
Range: 0-9990 ppm
Accuracy: ±2%
Conversion Factor: NaCl (avg. 0.5)
Cable Length: 46" (including sensor)
Calibration: Factory calibrated to NaCl 342 ppm. Re-calibration can be done separately for each line, or
simultaneously for both.
Power source: 2 x AA batteries (included)
Battery life: Approx. 12-18 months
Size: 11.6 x 6.8 x1.8 cm (4.6 x 2.6 x .7in.)
13 October 2017 34/39
35. Code: 060021
Dual TDS Sensor Probes for the DM-2
* Stainless steel sensors
* Probe: 1/4"
* Cable: 45" (114,3 cm.)
* Connector: dual 4+4-pin
* Thermometer pins: Yes
* Each sensor of the pair has a blue or red wrap and labeled "IN" or "OUT"
* Pressure Rating: 16bar @ +23°C
Code: 060054
PM1 OEM In-Line TDS purity monitor
An ideal monitor/alert for water coolers and other enclosed water purification systems. Alerts a user when
the filtration system requires service.
FEATURES
* OEM single line internal TDS monitor that is ideal for enclosed water purification systems.
* Includes a light and optional alarm that alerts the user service is required when the TDS level reaches the
pre-programmed set-point.
* User-defined set points (any even number between 2 and 200).
SPECIFICATIONS
* Range: 0-200 ppm (mg/L) * Accuracy: +/- 2% * Calibration: Factory calibrated * Alert: Warning light,
optional alarm * Light color: Either red or yellow * Light function: Either flashes or is steady * Alarm: Beeps
for 20 seconds, then goes silent * Power Source: AC 110V / 220V ±2% * Cable Length: 62.86 cm (24.75") *
Fittings: 1/4" standard, also available with 3/8" or 1/2" * Max. Water Pressure: 200 PSIG (at 23°C with a
1/4" fitting) * Circuit Board Dimensions: 8.9 x 6.9 x 3.8 cm (3.5 x 2.7 x 1.5 in.) * Weight: 266.5 g (9.4 oz.)
13 October 2017 35/39
36. Code: 060058
Electrolysis system for reverse osmosis test
Variants
Code Description
060058-01 Electrolysis demostration briefcase 24 VDC.
060058-02 Electrolysis replacement precipitator
060058-03 Aluminium electrode replacement for 060058-02
060058-04 Iron electrode replacement for 060058-02
060058-05 Electrolysis replacement ballast
060058-06 Empty electrolysis briefcase with foam
The produced electrolysis process, as well as its viewing, increases intensity and reaction rate depending
on the quantity of dissolved salts, among other factors. Water increases its electricity proportionally to the
quantity of dissolved salts it contains.
Contents of the briefcase:
* Electrolysis precipitator * 2 aluminium electrodes * 2 iron electrodes * Transformer *
Code: 060065
PM-2 external In-Line TDS Purity Monitor 220V.,110V.
Variants
Code Description
060065-01 PM-2 external In-Line TDS Purity Monitor 220V.
060065-02 PM-2 external In-Line TDS Purity Monitor 110V.
An ideal monitor/alert for water coolers and other enclosed water purification systems. Alerts a user when
the filtration system requires service.
FEATURES
* External single line internal TDS monitor that is ideal for most water purification systems.
* Includes a light and optional alarm that alerts the user service is required when the TDS level reaches the
pre-programmed set-point.
* User-defined set points (any even number between 2 and 200).
SPECIFICATIONS
* Range: 0-200 ppm (mg/L) * Accuracy: +/- 2% * Calibration: Factory calibrated * Alert: Warning light,
13 October 2017 36/39
37. optional alarm * Light color: Either red or yellow * Light function: Either flashes or is steady * Alarm: Beeps
for 20 seconds, then goes silent * Power Source: AC 110V / 220V ±2% * Cable Length: 62.86 cm (24.75") *
Fittings: 1/4" standard, also available with 3/8" or 1/2" * Max. Water Pressure: 200 PSIG (at 23°C with a
1/4" fitting) * Dimensions: 12.9 x 7.3 x 6 cm (5 x 2.9 x 2.4 in.) * Weight: 340 g (12 oz.)
Code: 060067
DM-2EC Commercial/residential in-Line Dual Conductivity
Monitor (5)
Inline ELECTRICAL CONDUCTIVITY monitor that can be installed on industrial water filtration systems
such as car washes, window washing, manufacturing, and food processing.
FEATURES
* Highly efficient and accurate due to its advanced microprocessor technology.
* Displays EC levels of the Feed Water and Product Water with in & out electrode probes.
* Auto-Off function conserves battery power. The unit shuts off automatically after 3 minutes.
* Dual Range - Measures from 0-999 µS, with a resolution of 1 ppm. From 1000 to 9990 µS, the resolution
is in 10 µS increments, indicated by a blinking 'x10' image.
* Factory Calibrated: calibrated to 1413 µS. The DM-2EC features digital calibration.
* Diagnostic error messaging
* Shielded sensor cables
* Comes equipped with 1/4 inch Mur-lok® Quick-Connect T-fittings. Also available with 3/8" or 1/2" fittings.
* Installs quickly and easily.
Differences from the DM-1:
* Measures EC (Electrical Conductivity) in µS (micro-Siemens).
* Designed for commercial/industrial applications.
* Stronger, water-resistant casing.
* Digital calibration can be done individually on each line.
* Improved design, including an extra large, easy-to-read LCD display.
* Longer, waterproof, shielded cables.
* Variable mounting bracket.
SPECIFICATIONS
* Range: 0-9990 µS
* Accuracy: ±2%
* Cable Length: 46" (including sensor), shielded cables
* Sensor: Dual, 1/4" diameter for quick-connect fittings (model SP-3, included)
* Digital Calibration: Digitally factory calibrated to 1413 µS. Re-calibration can be done separately for each
line.
* Power source: 2 x AA batteries (included)
* Battery life: Approx. 2 years
* Size: 11.6x6.8x1.8cm (4.6x2.6x.7in.)
13 October 2017 37/39
38. Shut-Off valves
Code: 060031
Shut-off valve 4 ways (6 screws) 1/4''
Code: 060032
Shut-off valve white 1/4''
Code: 060033
Shut-Off Valve ( White ) with Quick Connector 1/4''
Variants
Code Description
060033-02 Shut-Off Valve ( White ) with Quick Connector 1/4''
13 October 2017 38/39