SlideShare a Scribd company logo
1 of 8
Andrew ATM200-002
Teletilt Actuator, AISG 1.1…
_______________________________________
How to Buy
Call: 1-877-878-9134 for this product Email: sales@launch3.net Click to send an RFQ:
http://www.launch3telecom.com/andrew/atm200002.html
Part number: ATM200-002 Datasheets: https://www.launch3telecom.com/shared_
media/datasheet/Antennas_with_Factory_I
nstalled_Teletilt__Actuators.pdf
Manufacturer: Andrew Weight: N/A
Title: Teletilt Actuator, AISG
1.1…
Category: N/A
Description: Teletilt Actuator, AISG 1.1
default protocol
Connects to the base
station antenna for
remote electrical tilt
Factory s...
Genre: Wireless
Heci: N/A
Part Page URL:
About Us
Launch 3 Telecom is your one stop shop for all your Telecom and Data/Networking
Hardware needs and genuine Andrew replacement parts. We have loyally served our
customers since 2003. Our product expertise, quality customer service, competitive pricing
-on items like this Andrew ATM200-002 -- are a few of the reasons why more telecom
professionals buy from Launch 3 Telecom every day.
_______________________________________
Payment and Processing
We accept Visa, Mastercard, American Express and Paypal payments for this Andrew
ATM200-002. We can also accept Purchase Orders for Net Terms upon approval. Launch 3
Telecom does have a Government Cage Code so if this is for a Government purchase please
tells us! You may also call us at 877-878-9134 or email us at sales@launch3.net for our
credit card form. Please call us today to purchase this Andrew ATM200-002 item while
inventory and sale last.
Same Day Shipping, Order Confirmation and Order
Tracking
Once your order is placed for the Andrew ATM200-002, you may select from several
shipping methods, including UPS, Federal Express, DHL, USPS, 3 day, 2 day, overnight and
international methods. Orders received and approved before 3PM EST will generally ship
the same business day. You will receive an order confirmation email for your Andrew
ATM200-002 along with the tracking number as soon as it is available. The tracking number
will allow you to track your shipment in real time. We pack the Andrew ATM200-002 in
anti-static bubble wrap to ensure safe delivery. We will combine multiple items in one
shipment whenever possible to save on shipping time and costs. Because we have several
distribution points and vendor locations, sometimes orders will be divided into multiple
shipments, but never at extra cost to you.
_______________________________________
Warranty
Every item you purchase from us includes a warranty and our hassle-free return policy. We
stand by our product and your satisfaction is our goal. If you ever have questions or
concerns about your Andrew ATM200-002 order, simply contact our Customer Service
Department at 877-878-9134, Monday - Friday, 9 AM - 5 PM EST. Friendly customer service
reps are available to assist you with your order.
Services from Launch 3 Telecom
Launch 3 Telecom can also repair the Andrew
ATM200-002, provides maintenance contracts,
De-installation, Telecom Consignment and
Recycling. Please contact Launch 3 Telecom to
learn more about these services! Launch 3
Telecom specializes in installation of all
telecom related systems. Our team is equipped
to handle all telecom equipment including
cellular, Fixed Wireless, WiMAX, Central Office,
and more. No project is too small or too big,
and each is handled by a dedicated telecom
professional.
De-Installation - Our Network Installation
Experts will properly de-install your equipment,
package it, and ship it to our warehouse for
storage.
Testing - Our team of technicians will inspect
each piece of equipment thoroughly. If a piece
of equipment needs repair, we’ll provide the
resources and technology to guarantee each
piece is ready to be sold.
Asset Recovery - We can store your equipment
in one of our expansive warehouses located
around the country until your equipment is
sold so you can save on storage costs and avoid
cluttering your equipment floor.
Repair Services - Launch 3 Telecom is your one-
stop solution to your entire Telecom
Equipment & System repair. Our team of
dedicated professionals will get your system
back up and running quickly and efficiently. We
repair cell sites, central office switching,
combiners, data networking, transmission,
power supplies, microwave, radios, IP Cameras,
Sonet /SHD, power, power amps, CDMA, GSM,
TDMA, and PBX Keyphone.
Third Party Logistics - If you are currently
operating a direct route or if you are interested
in setting one up, Launch 3 Telecom would like
to discuss the opportunity of sending you
traffic. Contact us today to speak to a Call
Termination Specialist for more details at
voip@launch3telecom.com
Installation Instructions Antennas with Factory Installed Teletilt® Actuators Bulletin 639509 • Revision J • January 2010 Page 1 of 3 Andrew
Institute offers installation training. GENERAL INFORMATION • Instructions covered in this bulletin are specific for proper handling of the
factory installed AISG actuators on the antenna during installation, as well as their connectivity to the RET (Remote Electrical Tilt) system. •
Each actuator has been fitted and pre-tested in the factory to operate within the electrical tilt range of the antenna. It is recommended that
each actuator be connected to the controller prior to installation on the tower (WHILE ON THE GROUND) and checked to ensure that each
device moves accurately on command without restriction. Note that each actuator that is factory installed to an antenna is pre-configured
with the antenna model number, antenna type, and antenna serial number. The following configurations will need to be updated by the user
at the time of installation: • Installation date • Station ID • Mechanical tilt • Sector • Bearing • Technology • Height • Installer ID • Freq band
• Location To ensure that the actuator has been properly deployed, various set-tilt commands should be carried out at this stage. • Using the
ATC200-LITE-USB Portable Controller, run each actuator between min and max tilt several times. The motion of the actuator should be
unrestricted between its minimum and maximum downtilt positions. Compare the visual reading of downtilts through the viewing window in
the clear bushing on the antenna with the readings shown on the computer. Actuators are factory set to 2° downtilt. INSTALLATION
INSTRUCTIONS Actuator 1. Remove the antenna from the shipping box. Protective Shroud 2. Leave the protective shroud around the
actuator (Figure 1). Do not use the actuator or shroud as a lifting device for an antenna. Doing so is likely to damage the actuator and the
coupling attachment on the antenna. 3. Test actuators ON THE GROUND with a portable controller before the antenna is installed on the
tower. Figure 1. Actuators with Protective Shrouds. WARRANTY NOTICE Proper installation procedures must be followed when installing and
operating RET equipment. Failure to assure installations are done properly by trained installation personnel and to follow procedures
discussed in this bulletin may cause warranty for such products to be void. Andrew requires pretesting actuators on the ground prior to
installation, using the Andrew portable controller and the latest version of the controller software (available online at
www.commscope.com/andrew under Products→Antennas→Teletilt® RET System). This will verify proper actuator functionality and also
ensure that the latest available actuator firmware release is installed on the actuator. Failure to conduct pre-test and pre-installation
procedures defined by Andrew will void warranty. Unauthorized removal of a protective shroud to replace actuators voids the Andrew
warranty. SAFETY NOTICE The installation, maintenance, or removal of an antenna requires qualified, experienced personnel. Andrew
installation instructions are written for such installation personnel. Antenna systems should be inspected once a year by qualified personnel
to verify proper installation, maintenance, and condition of equipment. Andrew disclaims any liability or responsibility for the results of
improper or unsafe installation practices. It is recommended that transmit power be turned off when the field installation is performed.
Follow all applicable safety precautions as shown on this page. Do not install near power lines. Power lines, telephone lines, and guy wires
look the same. Assume any wire or line can electrocute you. Do not install on a wet or windy day or when lightning or thunder is in the area.
Do not use metal ladder. Wear shoes with rubber soles and heels. Wear protective clothing including a long-sleeved shirt and rubber gloves.
_x000C_Antennas with Factory Installed Teletilt® Actuators Andrew Solutions Bulletin 639509 • Revision J • January 2010 • Page 2 of 3
(Continued from page 1) Unauthorized removal of a protective shroud to replace actuators voids the Andrew warranty. 4. 5. After the
actuator has been tested and determined to operate satisfactorily, attach the mounting brackets to the back of the antenna (refer to the
installation bulletin supplied with the mounting kit). The connectors on the RET control cables are gender specific and are keyed to provide a
matching fit with the ports on the actuator and the other RET equipment. Refer to Figure 2 for an example of how to properly attach the RET
control cable connectors to the actuators for
daisy-chaining. Refer to Figures 3 through 6 for location of ports on various components used in a RET system. While threading the connectors
onto the RET equipment, turn the connector clockwise until hand tight ONLY. CAUTION: RET connections are weather resistant and must not
be weatherproofed. Male Input Port Connect female end of RET control cable to the male input port on the actuator. 6. 7. Secure the RET
control cable (that runs down toward the base station) to the tower structure, using cable ties, hangers, or similar fasteners, such as Andrew
40417 cable ties or 68MCLICK hangers. These main cables should be secured at 2 m intervals and at 1 m from either end. The cables feeding to
the actuators should be secured every 0.5 m, to avoid excessive wind vibration. See Bulletin 639581 for details about using Teletilt RET control
cables. It is recommended that the control cable be grounded at the tower base, top, and at 60 m intervals. Use Andrew ATGK-CABLE
grounding kit for tower base and at the top of the tower. ATGK-CABLE grounding kit is recommended for cable runs over 60 m (see Bulletin
639596). If the controller is installed permanently at a site, the ATLP200-001 lightning protection unit is recommended (see Bulletin 639098).
Female Output Port Connect male end of RET control cable to the female output port on the actuator. Male Input Port Connect female end
of RET control cable to the male input port on the actuator. Note: The male end of this control cable leads either out to another antenna or
down toward the controller. Figure 2. Daisy-Chaining the AISG RET Control Cable. _x000C_Antennas with Factory Installed Teletilt® Actuators
Andrew Solutions Bulletin 639509 • Revision J • January 2010 • Page 3 of 3 (Continued from page 2) Refer to the installation and operation
bulletins provided with the controller for proper setup and use of RET system components. 8. It is recommended that each actuator be re-
checked at this point, to ensure that each device moves accurately on command without restriction. Please register online at
www.commscope.com to receive e-mail announcements of downloadable software upgrades bundled with the latest antenna files. ATJB200-
A01-004 Shown Female Output Ports Female Output SMB Ports Male Input Port Figure 3. ATJB Series Junction Box RET Ports. or Female
Output AISG Port Figure 5. ATC300-1000 Controller RET Ports. Male Input Port Female Output Port (with protective cover) Figure 4. ATLP200-
001 Lightning Protection Unit RET Ports. Female Input Port Figure 6. ATC200-LITE-USB Controller RET Port. Andrew Solutions Customer
Support Center North America: +1-800-255-1479, Option 1 International: +1-779-435-6500, Option 1 www.commscope.com/andrew Visit our
Web site at aw.commscope.com or contact your local Andrew Solutions representative for more information. © 2010 CommScope, Inc. All
rights reserved. Andrew Solutions is a trademark of CommScope. All trademarks identified by ® or ™ are registered trademarks or
trademarks, respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement any
specifications or warranties relating to Andrew Solutions products or services. _x000C_

More Related Content

What's hot

Andrew APG-BDFDM-090
Andrew APG-BDFDM-090Andrew APG-BDFDM-090
Andrew APG-BDFDM-090savomir
 
Andrew ACU-A20-N
Andrew ACU-A20-NAndrew ACU-A20-N
Andrew ACU-A20-Nsavomir
 
Andrew AL5DF-PSA
Andrew AL5DF-PSAAndrew AL5DF-PSA
Andrew AL5DF-PSAsavomir
 
Andrew AL7DF-PSA
Andrew AL7DF-PSAAndrew AL7DF-PSA
Andrew AL7DF-PSAsavomir
 
Andrew AL6DF-PSA
Andrew AL6DF-PSAAndrew AL6DF-PSA
Andrew AL6DF-PSAsavomir
 
Andrew AL7NF-PSA
Andrew AL7NF-PSAAndrew AL7NF-PSA
Andrew AL7NF-PSAsavomir
 
Andrew SFX-ADMR
Andrew SFX-ADMRAndrew SFX-ADMR
Andrew SFX-ADMRsavomir
 
Andrew 540EZDF
Andrew 540EZDFAndrew 540EZDF
Andrew 540EZDFsavomir
 
Andrew 540EZDF
Andrew 540EZDFAndrew 540EZDF
Andrew 540EZDFsavomir
 
Andrew E15V85P14
Andrew E15V85P14Andrew E15V85P14
Andrew E15V85P14savomir
 
Andrew AL7DM-PSA
Andrew AL7DM-PSAAndrew AL7DM-PSA
Andrew AL7DM-PSAsavomir
 
Argus 020-584-20
Argus 020-584-20Argus 020-584-20
Argus 020-584-20savomir
 
Andrew 78EZDF
Andrew 78EZDFAndrew 78EZDF
Andrew 78EZDFsavomir
 
Andrew L4TNF-PSA
Andrew L4TNF-PSAAndrew L4TNF-PSA
Andrew L4TNF-PSAsavomir
 
Andrew L4TDF-PSA
Andrew L4TDF-PSAAndrew L4TDF-PSA
Andrew L4TDF-PSAsavomir
 
Andrew 114EZDF
Andrew 114EZDFAndrew 114EZDF
Andrew 114EZDFsavomir
 
Andrew ABT-DFDM-ADBA
Andrew ABT-DFDM-ADBAAndrew ABT-DFDM-ADBA
Andrew ABT-DFDM-ADBAsavomir
 
Commscope-Andrew ATSBT-TOP-FF
Commscope-Andrew ATSBT-TOP-FFCommscope-Andrew ATSBT-TOP-FF
Commscope-Andrew ATSBT-TOP-FFsavomir
 
Andrew APG-BNFNM-090
Andrew APG-BNFNM-090Andrew APG-BNFNM-090
Andrew APG-BNFNM-090savomir
 
Andrew SBNH-1D8585B
Andrew SBNH-1D8585BAndrew SBNH-1D8585B
Andrew SBNH-1D8585Bsavomir
 

What's hot (20)

Andrew APG-BDFDM-090
Andrew APG-BDFDM-090Andrew APG-BDFDM-090
Andrew APG-BDFDM-090
 
Andrew ACU-A20-N
Andrew ACU-A20-NAndrew ACU-A20-N
Andrew ACU-A20-N
 
Andrew AL5DF-PSA
Andrew AL5DF-PSAAndrew AL5DF-PSA
Andrew AL5DF-PSA
 
Andrew AL7DF-PSA
Andrew AL7DF-PSAAndrew AL7DF-PSA
Andrew AL7DF-PSA
 
Andrew AL6DF-PSA
Andrew AL6DF-PSAAndrew AL6DF-PSA
Andrew AL6DF-PSA
 
Andrew AL7NF-PSA
Andrew AL7NF-PSAAndrew AL7NF-PSA
Andrew AL7NF-PSA
 
Andrew SFX-ADMR
Andrew SFX-ADMRAndrew SFX-ADMR
Andrew SFX-ADMR
 
Andrew 540EZDF
Andrew 540EZDFAndrew 540EZDF
Andrew 540EZDF
 
Andrew 540EZDF
Andrew 540EZDFAndrew 540EZDF
Andrew 540EZDF
 
Andrew E15V85P14
Andrew E15V85P14Andrew E15V85P14
Andrew E15V85P14
 
Andrew AL7DM-PSA
Andrew AL7DM-PSAAndrew AL7DM-PSA
Andrew AL7DM-PSA
 
Argus 020-584-20
Argus 020-584-20Argus 020-584-20
Argus 020-584-20
 
Andrew 78EZDF
Andrew 78EZDFAndrew 78EZDF
Andrew 78EZDF
 
Andrew L4TNF-PSA
Andrew L4TNF-PSAAndrew L4TNF-PSA
Andrew L4TNF-PSA
 
Andrew L4TDF-PSA
Andrew L4TDF-PSAAndrew L4TDF-PSA
Andrew L4TDF-PSA
 
Andrew 114EZDF
Andrew 114EZDFAndrew 114EZDF
Andrew 114EZDF
 
Andrew ABT-DFDM-ADBA
Andrew ABT-DFDM-ADBAAndrew ABT-DFDM-ADBA
Andrew ABT-DFDM-ADBA
 
Commscope-Andrew ATSBT-TOP-FF
Commscope-Andrew ATSBT-TOP-FFCommscope-Andrew ATSBT-TOP-FF
Commscope-Andrew ATSBT-TOP-FF
 
Andrew APG-BNFNM-090
Andrew APG-BNFNM-090Andrew APG-BNFNM-090
Andrew APG-BNFNM-090
 
Andrew SBNH-1D8585B
Andrew SBNH-1D8585BAndrew SBNH-1D8585B
Andrew SBNH-1D8585B
 

Viewers also liked

Andrew F4A-DMDM-15-PX
Andrew F4A-DMDM-15-PXAndrew F4A-DMDM-15-PX
Andrew F4A-DMDM-15-PXsavomir
 
Meca 802-2-1.500V
Meca 802-2-1.500VMeca 802-2-1.500V
Meca 802-2-1.500Vsavomir
 
Andrew 252128
Andrew 252128Andrew 252128
Andrew 252128savomir
 
Andrew SG78-12B2U
Andrew SG78-12B2UAndrew SG78-12B2U
Andrew SG78-12B2Usavomir
 
Sat-Pak SP42-18MMNFP
Sat-Pak SP42-18MMNFPSat-Pak SP42-18MMNFP
Sat-Pak SP42-18MMNFPsavomir
 
Andrew WB-LB12-3
Andrew WB-LB12-3Andrew WB-LB12-3
Andrew WB-LB12-3savomir
 

Viewers also liked (6)

Andrew F4A-DMDM-15-PX
Andrew F4A-DMDM-15-PXAndrew F4A-DMDM-15-PX
Andrew F4A-DMDM-15-PX
 
Meca 802-2-1.500V
Meca 802-2-1.500VMeca 802-2-1.500V
Meca 802-2-1.500V
 
Andrew 252128
Andrew 252128Andrew 252128
Andrew 252128
 
Andrew SG78-12B2U
Andrew SG78-12B2UAndrew SG78-12B2U
Andrew SG78-12B2U
 
Sat-Pak SP42-18MMNFP
Sat-Pak SP42-18MMNFPSat-Pak SP42-18MMNFP
Sat-Pak SP42-18MMNFP
 
Andrew WB-LB12-3
Andrew WB-LB12-3Andrew WB-LB12-3
Andrew WB-LB12-3
 

Similar to Andrew ATM200-002

Powerwave 8220.10
Powerwave 8220.10Powerwave 8220.10
Powerwave 8220.10savomir
 
Powerwave 8212.40
Powerwave 8212.40Powerwave 8212.40
Powerwave 8212.40savomir
 
Andrew 158EZDM
Andrew 158EZDMAndrew 158EZDM
Andrew 158EZDMsavomir
 
Andrew AL7E158-PS
Andrew AL7E158-PSAndrew AL7E158-PS
Andrew AL7E158-PSsavomir
 
Andrew AWE-7812
Andrew AWE-7812Andrew AWE-7812
Andrew AWE-7812savomir
 
Commscope-Andrew 540EZNM
Commscope-Andrew 540EZNMCommscope-Andrew 540EZNM
Commscope-Andrew 540EZNMsavomir
 
Powerwave 8110.10
Powerwave 8110.10Powerwave 8110.10
Powerwave 8110.10savomir
 
Powerwave 8510.40
Powerwave 8510.40Powerwave 8510.40
Powerwave 8510.40savomir
 
Andrew ATS-A01-002
Andrew ATS-A01-002Andrew ATS-A01-002
Andrew ATS-A01-002savomir
 
Andrew ATS-A01-002
Andrew ATS-A01-002Andrew ATS-A01-002
Andrew ATS-A01-002savomir
 
Kathrein 860 10149
Kathrein 860 10149Kathrein 860 10149
Kathrein 860 10149savomir
 
Powerwave 8230.40
Powerwave 8230.40Powerwave 8230.40
Powerwave 8230.40savomir
 
Kathrein 860 10148
Kathrein 860 10148Kathrein 860 10148
Kathrein 860 10148savomir
 
Andrew C-8-CPUSE-N-AI6
Andrew C-8-CPUSE-N-AI6Andrew C-8-CPUSE-N-AI6
Andrew C-8-CPUSE-N-AI6savomir
 
Andrew CELLMAX-D-CPUSE
Andrew CELLMAX-D-CPUSEAndrew CELLMAX-D-CPUSE
Andrew CELLMAX-D-CPUSEsavomir
 
Andrew ATSBT-BOTTOM-MF
Andrew ATSBT-BOTTOM-MFAndrew ATSBT-BOTTOM-MF
Andrew ATSBT-BOTTOM-MFsavomir
 
Andrew A7TDF-PS
Andrew A7TDF-PSAndrew A7TDF-PS
Andrew A7TDF-PSsavomir
 
Andrew 78EZNM
Andrew 78EZNMAndrew 78EZNM
Andrew 78EZNMsavomir
 
Andrew 400PNR-C
Andrew 400PNR-CAndrew 400PNR-C
Andrew 400PNR-Csavomir
 
Andrew ATSBT-TOP-MF-4G
Andrew ATSBT-TOP-MF-4GAndrew ATSBT-TOP-MF-4G
Andrew ATSBT-TOP-MF-4Gsavomir
 

Similar to Andrew ATM200-002 (20)

Powerwave 8220.10
Powerwave 8220.10Powerwave 8220.10
Powerwave 8220.10
 
Powerwave 8212.40
Powerwave 8212.40Powerwave 8212.40
Powerwave 8212.40
 
Andrew 158EZDM
Andrew 158EZDMAndrew 158EZDM
Andrew 158EZDM
 
Andrew AL7E158-PS
Andrew AL7E158-PSAndrew AL7E158-PS
Andrew AL7E158-PS
 
Andrew AWE-7812
Andrew AWE-7812Andrew AWE-7812
Andrew AWE-7812
 
Commscope-Andrew 540EZNM
Commscope-Andrew 540EZNMCommscope-Andrew 540EZNM
Commscope-Andrew 540EZNM
 
Powerwave 8110.10
Powerwave 8110.10Powerwave 8110.10
Powerwave 8110.10
 
Powerwave 8510.40
Powerwave 8510.40Powerwave 8510.40
Powerwave 8510.40
 
Andrew ATS-A01-002
Andrew ATS-A01-002Andrew ATS-A01-002
Andrew ATS-A01-002
 
Andrew ATS-A01-002
Andrew ATS-A01-002Andrew ATS-A01-002
Andrew ATS-A01-002
 
Kathrein 860 10149
Kathrein 860 10149Kathrein 860 10149
Kathrein 860 10149
 
Powerwave 8230.40
Powerwave 8230.40Powerwave 8230.40
Powerwave 8230.40
 
Kathrein 860 10148
Kathrein 860 10148Kathrein 860 10148
Kathrein 860 10148
 
Andrew C-8-CPUSE-N-AI6
Andrew C-8-CPUSE-N-AI6Andrew C-8-CPUSE-N-AI6
Andrew C-8-CPUSE-N-AI6
 
Andrew CELLMAX-D-CPUSE
Andrew CELLMAX-D-CPUSEAndrew CELLMAX-D-CPUSE
Andrew CELLMAX-D-CPUSE
 
Andrew ATSBT-BOTTOM-MF
Andrew ATSBT-BOTTOM-MFAndrew ATSBT-BOTTOM-MF
Andrew ATSBT-BOTTOM-MF
 
Andrew A7TDF-PS
Andrew A7TDF-PSAndrew A7TDF-PS
Andrew A7TDF-PS
 
Andrew 78EZNM
Andrew 78EZNMAndrew 78EZNM
Andrew 78EZNM
 
Andrew 400PNR-C
Andrew 400PNR-CAndrew 400PNR-C
Andrew 400PNR-C
 
Andrew ATSBT-TOP-MF-4G
Andrew ATSBT-TOP-MF-4GAndrew ATSBT-TOP-MF-4G
Andrew ATSBT-TOP-MF-4G
 

Andrew ATM200-002

  • 1.
  • 2. Andrew ATM200-002 Teletilt Actuator, AISG 1.1… _______________________________________ How to Buy Call: 1-877-878-9134 for this product Email: sales@launch3.net Click to send an RFQ: http://www.launch3telecom.com/andrew/atm200002.html
  • 3. Part number: ATM200-002 Datasheets: https://www.launch3telecom.com/shared_ media/datasheet/Antennas_with_Factory_I nstalled_Teletilt__Actuators.pdf Manufacturer: Andrew Weight: N/A Title: Teletilt Actuator, AISG 1.1… Category: N/A Description: Teletilt Actuator, AISG 1.1 default protocol Connects to the base station antenna for remote electrical tilt Factory s... Genre: Wireless Heci: N/A Part Page URL:
  • 4. About Us Launch 3 Telecom is your one stop shop for all your Telecom and Data/Networking Hardware needs and genuine Andrew replacement parts. We have loyally served our customers since 2003. Our product expertise, quality customer service, competitive pricing -on items like this Andrew ATM200-002 -- are a few of the reasons why more telecom professionals buy from Launch 3 Telecom every day. _______________________________________ Payment and Processing We accept Visa, Mastercard, American Express and Paypal payments for this Andrew ATM200-002. We can also accept Purchase Orders for Net Terms upon approval. Launch 3 Telecom does have a Government Cage Code so if this is for a Government purchase please tells us! You may also call us at 877-878-9134 or email us at sales@launch3.net for our credit card form. Please call us today to purchase this Andrew ATM200-002 item while inventory and sale last.
  • 5. Same Day Shipping, Order Confirmation and Order Tracking Once your order is placed for the Andrew ATM200-002, you may select from several shipping methods, including UPS, Federal Express, DHL, USPS, 3 day, 2 day, overnight and international methods. Orders received and approved before 3PM EST will generally ship the same business day. You will receive an order confirmation email for your Andrew ATM200-002 along with the tracking number as soon as it is available. The tracking number will allow you to track your shipment in real time. We pack the Andrew ATM200-002 in anti-static bubble wrap to ensure safe delivery. We will combine multiple items in one shipment whenever possible to save on shipping time and costs. Because we have several distribution points and vendor locations, sometimes orders will be divided into multiple shipments, but never at extra cost to you. _______________________________________ Warranty Every item you purchase from us includes a warranty and our hassle-free return policy. We stand by our product and your satisfaction is our goal. If you ever have questions or concerns about your Andrew ATM200-002 order, simply contact our Customer Service Department at 877-878-9134, Monday - Friday, 9 AM - 5 PM EST. Friendly customer service reps are available to assist you with your order.
  • 6. Services from Launch 3 Telecom Launch 3 Telecom can also repair the Andrew ATM200-002, provides maintenance contracts, De-installation, Telecom Consignment and Recycling. Please contact Launch 3 Telecom to learn more about these services! Launch 3 Telecom specializes in installation of all telecom related systems. Our team is equipped to handle all telecom equipment including cellular, Fixed Wireless, WiMAX, Central Office, and more. No project is too small or too big, and each is handled by a dedicated telecom professional. De-Installation - Our Network Installation Experts will properly de-install your equipment, package it, and ship it to our warehouse for storage. Testing - Our team of technicians will inspect each piece of equipment thoroughly. If a piece of equipment needs repair, we’ll provide the resources and technology to guarantee each piece is ready to be sold. Asset Recovery - We can store your equipment in one of our expansive warehouses located around the country until your equipment is sold so you can save on storage costs and avoid cluttering your equipment floor. Repair Services - Launch 3 Telecom is your one- stop solution to your entire Telecom Equipment & System repair. Our team of dedicated professionals will get your system back up and running quickly and efficiently. We repair cell sites, central office switching, combiners, data networking, transmission, power supplies, microwave, radios, IP Cameras, Sonet /SHD, power, power amps, CDMA, GSM, TDMA, and PBX Keyphone. Third Party Logistics - If you are currently operating a direct route or if you are interested in setting one up, Launch 3 Telecom would like to discuss the opportunity of sending you traffic. Contact us today to speak to a Call Termination Specialist for more details at voip@launch3telecom.com
  • 7. Installation Instructions Antennas with Factory Installed Teletilt® Actuators Bulletin 639509 • Revision J • January 2010 Page 1 of 3 Andrew Institute offers installation training. GENERAL INFORMATION • Instructions covered in this bulletin are specific for proper handling of the factory installed AISG actuators on the antenna during installation, as well as their connectivity to the RET (Remote Electrical Tilt) system. • Each actuator has been fitted and pre-tested in the factory to operate within the electrical tilt range of the antenna. It is recommended that each actuator be connected to the controller prior to installation on the tower (WHILE ON THE GROUND) and checked to ensure that each device moves accurately on command without restriction. Note that each actuator that is factory installed to an antenna is pre-configured with the antenna model number, antenna type, and antenna serial number. The following configurations will need to be updated by the user at the time of installation: • Installation date • Station ID • Mechanical tilt • Sector • Bearing • Technology • Height • Installer ID • Freq band • Location To ensure that the actuator has been properly deployed, various set-tilt commands should be carried out at this stage. • Using the ATC200-LITE-USB Portable Controller, run each actuator between min and max tilt several times. The motion of the actuator should be unrestricted between its minimum and maximum downtilt positions. Compare the visual reading of downtilts through the viewing window in the clear bushing on the antenna with the readings shown on the computer. Actuators are factory set to 2° downtilt. INSTALLATION INSTRUCTIONS Actuator 1. Remove the antenna from the shipping box. Protective Shroud 2. Leave the protective shroud around the actuator (Figure 1). Do not use the actuator or shroud as a lifting device for an antenna. Doing so is likely to damage the actuator and the coupling attachment on the antenna. 3. Test actuators ON THE GROUND with a portable controller before the antenna is installed on the tower. Figure 1. Actuators with Protective Shrouds. WARRANTY NOTICE Proper installation procedures must be followed when installing and operating RET equipment. Failure to assure installations are done properly by trained installation personnel and to follow procedures discussed in this bulletin may cause warranty for such products to be void. Andrew requires pretesting actuators on the ground prior to installation, using the Andrew portable controller and the latest version of the controller software (available online at www.commscope.com/andrew under Products→Antennas→Teletilt® RET System). This will verify proper actuator functionality and also ensure that the latest available actuator firmware release is installed on the actuator. Failure to conduct pre-test and pre-installation procedures defined by Andrew will void warranty. Unauthorized removal of a protective shroud to replace actuators voids the Andrew warranty. SAFETY NOTICE The installation, maintenance, or removal of an antenna requires qualified, experienced personnel. Andrew installation instructions are written for such installation personnel. Antenna systems should be inspected once a year by qualified personnel to verify proper installation, maintenance, and condition of equipment. Andrew disclaims any liability or responsibility for the results of improper or unsafe installation practices. It is recommended that transmit power be turned off when the field installation is performed. Follow all applicable safety precautions as shown on this page. Do not install near power lines. Power lines, telephone lines, and guy wires look the same. Assume any wire or line can electrocute you. Do not install on a wet or windy day or when lightning or thunder is in the area. Do not use metal ladder. Wear shoes with rubber soles and heels. Wear protective clothing including a long-sleeved shirt and rubber gloves. _x000C_Antennas with Factory Installed Teletilt® Actuators Andrew Solutions Bulletin 639509 • Revision J • January 2010 • Page 2 of 3 (Continued from page 1) Unauthorized removal of a protective shroud to replace actuators voids the Andrew warranty. 4. 5. After the actuator has been tested and determined to operate satisfactorily, attach the mounting brackets to the back of the antenna (refer to the installation bulletin supplied with the mounting kit). The connectors on the RET control cables are gender specific and are keyed to provide a matching fit with the ports on the actuator and the other RET equipment. Refer to Figure 2 for an example of how to properly attach the RET control cable connectors to the actuators for
  • 8. daisy-chaining. Refer to Figures 3 through 6 for location of ports on various components used in a RET system. While threading the connectors onto the RET equipment, turn the connector clockwise until hand tight ONLY. CAUTION: RET connections are weather resistant and must not be weatherproofed. Male Input Port Connect female end of RET control cable to the male input port on the actuator. 6. 7. Secure the RET control cable (that runs down toward the base station) to the tower structure, using cable ties, hangers, or similar fasteners, such as Andrew 40417 cable ties or 68MCLICK hangers. These main cables should be secured at 2 m intervals and at 1 m from either end. The cables feeding to the actuators should be secured every 0.5 m, to avoid excessive wind vibration. See Bulletin 639581 for details about using Teletilt RET control cables. It is recommended that the control cable be grounded at the tower base, top, and at 60 m intervals. Use Andrew ATGK-CABLE grounding kit for tower base and at the top of the tower. ATGK-CABLE grounding kit is recommended for cable runs over 60 m (see Bulletin 639596). If the controller is installed permanently at a site, the ATLP200-001 lightning protection unit is recommended (see Bulletin 639098). Female Output Port Connect male end of RET control cable to the female output port on the actuator. Male Input Port Connect female end of RET control cable to the male input port on the actuator. Note: The male end of this control cable leads either out to another antenna or down toward the controller. Figure 2. Daisy-Chaining the AISG RET Control Cable. _x000C_Antennas with Factory Installed Teletilt® Actuators Andrew Solutions Bulletin 639509 • Revision J • January 2010 • Page 3 of 3 (Continued from page 2) Refer to the installation and operation bulletins provided with the controller for proper setup and use of RET system components. 8. It is recommended that each actuator be re- checked at this point, to ensure that each device moves accurately on command without restriction. Please register online at www.commscope.com to receive e-mail announcements of downloadable software upgrades bundled with the latest antenna files. ATJB200- A01-004 Shown Female Output Ports Female Output SMB Ports Male Input Port Figure 3. ATJB Series Junction Box RET Ports. or Female Output AISG Port Figure 5. ATC300-1000 Controller RET Ports. Male Input Port Female Output Port (with protective cover) Figure 4. ATLP200- 001 Lightning Protection Unit RET Ports. Female Input Port Figure 6. ATC200-LITE-USB Controller RET Port. Andrew Solutions Customer Support Center North America: +1-800-255-1479, Option 1 International: +1-779-435-6500, Option 1 www.commscope.com/andrew Visit our Web site at aw.commscope.com or contact your local Andrew Solutions representative for more information. © 2010 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope. All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to Andrew Solutions products or services. _x000C_