SlideShare a Scribd company logo
1 of 7
Argus 020-584-20
SM03 24VDC Distribution Center
_______________________________________
How to Buy
Call: 1-877-878-9134 for this product Email: sales@launch3.net Click to send an RFQ:
http://www.launch3telecom.com/argus/02058420.html
Part number: 020-584-20 Datasheets: https://www.launch3telecom.com/shared_
media/datasheet/020-584-20.pdf
Manufacturer: Argus Weight: N/A
Title: SM03 24VDC Distribution
Center
Category: N/A
Description: AM Plug-in type breakers
(16) Load breaker
positions (front access)
Standard rear access gnd
bar
Optional Front Access g...
Genre: N/A
Heci: N/A
Part Page URL:
About Us
Launch 3 Telecom is your one stop shop for all your Telecom and Data/Networking
Hardware needs and genuine Argus replacement parts. We have loyally served our
customers since 2003. Our product expertise, quality customer service, competitive pricing
-on items like this Argus 020-584-20 -- are a few of the reasons why more telecom
professionals buy from Launch 3 Telecom every day.
_______________________________________
Payment and Processing
We accept Visa, Mastercard, American Express and Paypal payments for this Argus 020-
584-20. We can also accept Purchase Orders for Net Terms upon approval. Launch 3
Telecom does have a Government Cage Code so if this is for a Government purchase please
tells us! You may also call us at 877-878-9134 or email us at sales@launch3.net for our
credit card form. Please call us today to purchase this Argus 020-584-20 item while
inventory and sale last.
Same Day Shipping, Order Confirmation and Order
Tracking
Once your order is placed for the Argus 020-584-20, you may select from several shipping
methods, including UPS, Federal Express, DHL, USPS, 3 day, 2 day, overnight and
international methods. Orders received and approved before 3PM EST will generally ship
the same business day. You will receive an order confirmation email for your Argus 020-
584-20 along with the tracking number as soon as it is available. The tracking number will
allow you to track your shipment in real time. We pack the Argus 020-584-20 in anti-static
bubble wrap to ensure safe delivery. We will combine multiple items in one shipment
whenever possible to save on shipping time and costs. Because we have several
distribution points and vendor locations, sometimes orders will be divided into multiple
shipments, but never at extra cost to you.
_______________________________________
Warranty
Every item you purchase from us includes a warranty and our hassle-free return policy. We
stand by our product and your satisfaction is our goal. If you ever have questions or
concerns about your Argus 020-584-20 order, simply contact our Customer Service
Department at 877-878-9134, Monday - Friday, 9 AM - 5 PM EST. Friendly customer service
reps are available to assist you with your order.
Services from Launch 3 Telecom
Launch 3 Telecom can also repair the Argus
020-584-20, provides maintenance contracts,
De-installation, Telecom Consignment and
Recycling. Please contact Launch 3 Telecom to
learn more about these services! Launch 3
Telecom specializes in installation of all
telecom related systems. Our team is equipped
to handle all telecom equipment including
cellular, Fixed Wireless, WiMAX, Central Office,
and more. No project is too small or too big,
and each is handled by a dedicated telecom
professional.
De-Installation - Our Network Installation
Experts will properly de-install your equipment,
package it, and ship it to our warehouse for
storage.
Testing - Our team of technicians will inspect
each piece of equipment thoroughly. If a piece
of equipment needs repair, we’ll provide the
resources and technology to guarantee each
piece is ready to be sold.
Asset Recovery - We can store your equipment
in one of our expansive warehouses located
around the country until your equipment is
sold so you can save on storage costs and avoid
cluttering your equipment floor.
Repair Services - Launch 3 Telecom is your one-
stop solution to your entire Telecom
Equipment & System repair. Our team of
dedicated professionals will get your system
back up and running quickly and efficiently. We
repair cell sites, central office switching,
combiners, data networking, transmission,
power supplies, microwave, radios, IP Cameras,
Sonet /SHD, power, power amps, CDMA, GSM,
TDMA, and PBX Keyphone.
Third Party Logistics - If you are currently
operating a direct route or if you are interested
in setting one up, Launch 3 Telecom would like
to discuss the opportunity of sending you
traffic. Contact us today to speak to a Call
Termination Specialist for more details at
voip@launch3telecom.com
Power ® Front Access Distribution Center >_x0007_ he DCP01 400A Distribution Center is an integrated distribution and system controller
package designed T for mid-sized power applications. >_x0007_ he compact unit installs in four rack units of space. The front access design
ensures quick, easy T installation and setup. >All DC cable connections are connected via two-hole termination lugs. >Up to 16 plug-in
breakers can be installed at up to 100A per position. >Optional LVD’s and shunts may also be installed. >_x0007_ he DCP01 incorporates the
field-proven Cordex system controller as part of the standard package. T This includes, but is not limited to, the following alarms and
controls: high/low voltage alarm, fuse/breaker alarm, load in/out, temperature compensation, auto equalize, and advanced battery
monitoring. >_x0007_ he front panel also incorporates rocker-type switches for optional battery disconnect and/or load T disconnect. ® title:
020-584-20 Front Access Distribution Center Document: 020-584-20.vsd DRW: Revision: A Member of The Alpha Group™ date: Jan 19, 2009
sheet: _x000C_>DC Power Solutions Front Access Distribution Center Product Number:....................020-584-20
Description:.............................DCP01 400 Amp Distribution Center Weight:....................................15.9kg Size
mm:......................................175H x 427W x 381D in:.........................................6.9H x 16.8W x 15D Weight:....................................35lbs
Finishing Detail:......................_x0007_ elded Steel, Powder Coat “Hybrid Gray”:Protech HS312 A355 . W Capacity:. ..............................._x0007_
00A, 16 breaker positions. (System may be configured with 8 breaker positions and 8 . 4 front access ground connections.)
Multiple shunt and LVD combinations. _x0007_ Local rectifier control and monitoring via onboard CXC. Certification:.
..........................N/A . Standards:..............................N/A . Drawing References:..............020-584-20; Bill of Materials 020-
584-04: Assembly 020-584-05: Schematic 020-584-06; Outline 020-584-B2; User Manual List Options:
Additional: 0,55; 400 Amp, 16 Position UDC 1; 24VDC, Negative Ground 2; 48VDC 19; 19” Center Mount 23; 23” Center Mount 25; 23” Flush
Mount 71; 24VDC Load Disconnect 72; 48VDC Load Disconnect 78; Cordex CXC 80,1; 24VDC Battery Disconnect 80,2; 48VDC Battery Disconnect
82; Jumper, No 48VDC Load Disconnect 83; 600A battery shunt (used with L71/72 and no L80) 84; 600A Load Shunt (used with L80 and no
L71/72) 85; 600A shunt (used with L71/72 and L80) 86; 8 breaker positions with front access ground bar) 100; 5A Breaker 101; 10A Breaker
102; 20A Breaker 103; 30A Breaker 104; 40A Breaker 105; 50A Breaker 106; 60A Breaker 107; 70A Breaker 108; 80A Breaker 109; 90A Breaker
110; 100A Breaker 111; 15A Breaker 112; 25A Breaker ® Ground Bar:. .................._x0007_ round: 4x ⅜"-16 tapped holes . G on 1” centers
Load returns:.................._x0007_ "-20 tapped holes on ⅝" centers ¼ (1 per breaker) Load Connections:........._x0007_ "-20 tapped holes on ⅝"
centers ¼ (1 per breaker) Rectifier Termination:. ...._x0007_ x ⅜"-16 tapped holes on . 2 1" centers Battery Termination:......._x0007_ x ⅜"-16
tapped holes on 2 1" centers Breaker Option:.............._x0007_ M-type mid-trip plug-in breaker, A 5∕16" bullet-style terminals; no alarm
jumper wires are required. Selectors:......................._x0007_ attery disconnect and load . B disconnect Alarm:.............................Form C relay
contacts via CXC title: 020-584-20 Front Access Distribution Center Document: 020-584-20.vsd DRW: Revision: A Member of The Alpha
Group™ date: Jan 19, 2009 sheet: _x000C_

More Related Content

What's hot (20)

Argus 012-012-20
Argus 012-012-20Argus 012-012-20
Argus 012-012-20
 
Andrew L7TDF-PS
Andrew L7TDF-PSAndrew L7TDF-PS
Andrew L7TDF-PS
 
Andrew ATM200-002
Andrew ATM200-002Andrew ATM200-002
Andrew ATM200-002
 
Andrew L4TNF-PSA
Andrew L4TNF-PSAAndrew L4TNF-PSA
Andrew L4TNF-PSA
 
Andrew ACU-A20-N
Andrew ACU-A20-NAndrew ACU-A20-N
Andrew ACU-A20-N
 
Andrew 158EZNF
Andrew 158EZNFAndrew 158EZNF
Andrew 158EZNF
 
Andrew APTDC-BDFDM-DB
Andrew APTDC-BDFDM-DBAndrew APTDC-BDFDM-DB
Andrew APTDC-BDFDM-DB
 
Commscope-Andrew 2UNPX203.6R2
Commscope-Andrew 2UNPX203.6R2Commscope-Andrew 2UNPX203.6R2
Commscope-Andrew 2UNPX203.6R2
 
Mini-Circuits BW-S15W2
Mini-Circuits BW-S15W2Mini-Circuits BW-S15W2
Mini-Circuits BW-S15W2
 
Commscope-Andrew SBHH-1D6516DS
Commscope-Andrew SBHH-1D6516DSCommscope-Andrew SBHH-1D6516DS
Commscope-Andrew SBHH-1D6516DS
 
Andrew L5PNF-RPC
Andrew L5PNF-RPCAndrew L5PNF-RPC
Andrew L5PNF-RPC
 
Andrew L6PNF-RPC
Andrew L6PNF-RPCAndrew L6PNF-RPC
Andrew L6PNF-RPC
 
Kathrein 860 10149
Kathrein 860 10149Kathrein 860 10149
Kathrein 860 10149
 
Andrew 78EZDF
Andrew 78EZDFAndrew 78EZDF
Andrew 78EZDF
 
Kathrein 860-10025
Kathrein 860-10025Kathrein 860-10025
Kathrein 860-10025
 
Andrew ATS-B01-003
Andrew ATS-B01-003Andrew ATS-B01-003
Andrew ATS-B01-003
 
Computer Sale in Bangalore
Computer Sale in BangaloreComputer Sale in Bangalore
Computer Sale in Bangalore
 
Kathrein 860 10148
Kathrein 860 10148Kathrein 860 10148
Kathrein 860 10148
 
Andrew DBXLH-6565A-R2M
Andrew DBXLH-6565A-R2MAndrew DBXLH-6565A-R2M
Andrew DBXLH-6565A-R2M
 
Commscope-Andrew CTSDG-06513-XDM
Commscope-Andrew CTSDG-06513-XDMCommscope-Andrew CTSDG-06513-XDM
Commscope-Andrew CTSDG-06513-XDM
 

Viewers also liked (18)

Rosenberger TH534-EUS23
Rosenberger TH534-EUS23Rosenberger TH534-EUS23
Rosenberger TH534-EUS23
 
Erico 65PLUSF20
Erico 65PLUSF20Erico 65PLUSF20
Erico 65PLUSF20
 
Fujitsu FC9616FAC2
Fujitsu FC9616FAC2Fujitsu FC9616FAC2
Fujitsu FC9616FAC2
 
EnerSys CS71362.03
EnerSys CS71362.03EnerSys CS71362.03
EnerSys CS71362.03
 
Ericsson TSR432151/1000
Ericsson TSR432151/1000Ericsson TSR432151/1000
Ericsson TSR432151/1000
 
Andrew EPD3603-DCS6
Andrew EPD3603-DCS6Andrew EPD3603-DCS6
Andrew EPD3603-DCS6
 
I-Line 294557
I-Line 294557I-Line 294557
I-Line 294557
 
ADC ADCCMFSB23-5
ADC ADCCMFSB23-5ADC ADCCMFSB23-5
ADC ADCCMFSB23-5
 
Panduit PSL-SCBD-SS
Panduit PSL-SCBD-SSPanduit PSL-SCBD-SS
Panduit PSL-SCBD-SS
 
Andrew BFC-112-50
Andrew BFC-112-50Andrew BFC-112-50
Andrew BFC-112-50
 
Burndy YA6CL2TC38
Burndy YA6CL2TC38Burndy YA6CL2TC38
Burndy YA6CL2TC38
 
Huber+Suhner 84016540
Huber+Suhner 84016540Huber+Suhner 84016540
Huber+Suhner 84016540
 
Wireless Solutions WS-BH114
Wireless Solutions WS-BH114Wireless Solutions WS-BH114
Wireless Solutions WS-BH114
 
Launch 3 L3-UB-4352
Launch 3 L3-UB-4352Launch 3 L3-UB-4352
Launch 3 L3-UB-4352
 
Ericsson SXK 109 9212/1
Ericsson SXK 109 9212/1Ericsson SXK 109 9212/1
Ericsson SXK 109 9212/1
 
Ericsson NTM2013898/3
Ericsson NTM2013898/3Ericsson NTM2013898/3
Ericsson NTM2013898/3
 
Times Microwave EZ-600-716MH
Times Microwave EZ-600-716MHTimes Microwave EZ-600-716MH
Times Microwave EZ-600-716MH
 
TTC 80-49480-01
TTC 80-49480-01TTC 80-49480-01
TTC 80-49480-01
 

Similar to Argus 020-584-20 (20)

Powerwave 8230.40
Powerwave 8230.40Powerwave 8230.40
Powerwave 8230.40
 
Powerwave 8212.40
Powerwave 8212.40Powerwave 8212.40
Powerwave 8212.40
 
Powerwave 7070.30
Powerwave 7070.30Powerwave 7070.30
Powerwave 7070.30
 
Powerwave OS-1921-H0-XXX
Powerwave OS-1921-H0-XXXPowerwave OS-1921-H0-XXX
Powerwave OS-1921-H0-XXX
 
Powerwave 8220.10
Powerwave 8220.10Powerwave 8220.10
Powerwave 8220.10
 
Powerwave 7072.30
Powerwave 7072.30Powerwave 7072.30
Powerwave 7072.30
 
Powerwave 7070.10
Powerwave 7070.10Powerwave 7070.10
Powerwave 7070.10
 
Argus 030-594-20
Argus 030-594-20Argus 030-594-20
Argus 030-594-20
 
123eWireless 123-1DMDM-18-PA
123eWireless 123-1DMDM-18-PA123eWireless 123-1DMDM-18-PA
123eWireless 123-1DMDM-18-PA
 
Argus 010-539-20
Argus 010-539-20Argus 010-539-20
Argus 010-539-20
 
Andrew ATC300-1000
Andrew ATC300-1000Andrew ATC300-1000
Andrew ATC300-1000
 
Powerwave OS-1821-H0-XXX
Powerwave OS-1821-H0-XXXPowerwave OS-1821-H0-XXX
Powerwave OS-1821-H0-XXX
 
Andrew C240-DMQR-20
Andrew C240-DMQR-20Andrew C240-DMQR-20
Andrew C240-DMQR-20
 
Powerwave 8110.40
Powerwave 8110.40Powerwave 8110.40
Powerwave 8110.40
 
Andrew C240-QMRQMR-35
Andrew C240-QMRQMR-35Andrew C240-QMRQMR-35
Andrew C240-QMRQMR-35
 
Andrew C240-SRQMR-35
Andrew C240-SRQMR-35Andrew C240-SRQMR-35
Andrew C240-SRQMR-35
 
Powerwave P65-15-XXCH-N
Powerwave P65-15-XXCH-NPowerwave P65-15-XXCH-N
Powerwave P65-15-XXCH-N
 
Andrew APG-BDFDM-090
Andrew APG-BDFDM-090Andrew APG-BDFDM-090
Andrew APG-BDFDM-090
 
Andrew C240-SRQMR-1
Andrew C240-SRQMR-1Andrew C240-SRQMR-1
Andrew C240-SRQMR-1
 
ADC FL2-C2J0024PW-2A00
ADC FL2-C2J0024PW-2A00ADC FL2-C2J0024PW-2A00
ADC FL2-C2J0024PW-2A00
 

Argus 020-584-20

  • 1.
  • 2. Argus 020-584-20 SM03 24VDC Distribution Center _______________________________________ How to Buy Call: 1-877-878-9134 for this product Email: sales@launch3.net Click to send an RFQ: http://www.launch3telecom.com/argus/02058420.html
  • 3. Part number: 020-584-20 Datasheets: https://www.launch3telecom.com/shared_ media/datasheet/020-584-20.pdf Manufacturer: Argus Weight: N/A Title: SM03 24VDC Distribution Center Category: N/A Description: AM Plug-in type breakers (16) Load breaker positions (front access) Standard rear access gnd bar Optional Front Access g... Genre: N/A Heci: N/A Part Page URL:
  • 4. About Us Launch 3 Telecom is your one stop shop for all your Telecom and Data/Networking Hardware needs and genuine Argus replacement parts. We have loyally served our customers since 2003. Our product expertise, quality customer service, competitive pricing -on items like this Argus 020-584-20 -- are a few of the reasons why more telecom professionals buy from Launch 3 Telecom every day. _______________________________________ Payment and Processing We accept Visa, Mastercard, American Express and Paypal payments for this Argus 020- 584-20. We can also accept Purchase Orders for Net Terms upon approval. Launch 3 Telecom does have a Government Cage Code so if this is for a Government purchase please tells us! You may also call us at 877-878-9134 or email us at sales@launch3.net for our credit card form. Please call us today to purchase this Argus 020-584-20 item while inventory and sale last.
  • 5. Same Day Shipping, Order Confirmation and Order Tracking Once your order is placed for the Argus 020-584-20, you may select from several shipping methods, including UPS, Federal Express, DHL, USPS, 3 day, 2 day, overnight and international methods. Orders received and approved before 3PM EST will generally ship the same business day. You will receive an order confirmation email for your Argus 020- 584-20 along with the tracking number as soon as it is available. The tracking number will allow you to track your shipment in real time. We pack the Argus 020-584-20 in anti-static bubble wrap to ensure safe delivery. We will combine multiple items in one shipment whenever possible to save on shipping time and costs. Because we have several distribution points and vendor locations, sometimes orders will be divided into multiple shipments, but never at extra cost to you. _______________________________________ Warranty Every item you purchase from us includes a warranty and our hassle-free return policy. We stand by our product and your satisfaction is our goal. If you ever have questions or concerns about your Argus 020-584-20 order, simply contact our Customer Service Department at 877-878-9134, Monday - Friday, 9 AM - 5 PM EST. Friendly customer service reps are available to assist you with your order.
  • 6. Services from Launch 3 Telecom Launch 3 Telecom can also repair the Argus 020-584-20, provides maintenance contracts, De-installation, Telecom Consignment and Recycling. Please contact Launch 3 Telecom to learn more about these services! Launch 3 Telecom specializes in installation of all telecom related systems. Our team is equipped to handle all telecom equipment including cellular, Fixed Wireless, WiMAX, Central Office, and more. No project is too small or too big, and each is handled by a dedicated telecom professional. De-Installation - Our Network Installation Experts will properly de-install your equipment, package it, and ship it to our warehouse for storage. Testing - Our team of technicians will inspect each piece of equipment thoroughly. If a piece of equipment needs repair, we’ll provide the resources and technology to guarantee each piece is ready to be sold. Asset Recovery - We can store your equipment in one of our expansive warehouses located around the country until your equipment is sold so you can save on storage costs and avoid cluttering your equipment floor. Repair Services - Launch 3 Telecom is your one- stop solution to your entire Telecom Equipment & System repair. Our team of dedicated professionals will get your system back up and running quickly and efficiently. We repair cell sites, central office switching, combiners, data networking, transmission, power supplies, microwave, radios, IP Cameras, Sonet /SHD, power, power amps, CDMA, GSM, TDMA, and PBX Keyphone. Third Party Logistics - If you are currently operating a direct route or if you are interested in setting one up, Launch 3 Telecom would like to discuss the opportunity of sending you traffic. Contact us today to speak to a Call Termination Specialist for more details at voip@launch3telecom.com
  • 7. Power ® Front Access Distribution Center >_x0007_ he DCP01 400A Distribution Center is an integrated distribution and system controller package designed T for mid-sized power applications. >_x0007_ he compact unit installs in four rack units of space. The front access design ensures quick, easy T installation and setup. >All DC cable connections are connected via two-hole termination lugs. >Up to 16 plug-in breakers can be installed at up to 100A per position. >Optional LVD’s and shunts may also be installed. >_x0007_ he DCP01 incorporates the field-proven Cordex system controller as part of the standard package. T This includes, but is not limited to, the following alarms and controls: high/low voltage alarm, fuse/breaker alarm, load in/out, temperature compensation, auto equalize, and advanced battery monitoring. >_x0007_ he front panel also incorporates rocker-type switches for optional battery disconnect and/or load T disconnect. ® title: 020-584-20 Front Access Distribution Center Document: 020-584-20.vsd DRW: Revision: A Member of The Alpha Group™ date: Jan 19, 2009 sheet: _x000C_>DC Power Solutions Front Access Distribution Center Product Number:....................020-584-20 Description:.............................DCP01 400 Amp Distribution Center Weight:....................................15.9kg Size mm:......................................175H x 427W x 381D in:.........................................6.9H x 16.8W x 15D Weight:....................................35lbs Finishing Detail:......................_x0007_ elded Steel, Powder Coat “Hybrid Gray”:Protech HS312 A355 . W Capacity:. ..............................._x0007_ 00A, 16 breaker positions. (System may be configured with 8 breaker positions and 8 . 4 front access ground connections.) Multiple shunt and LVD combinations. _x0007_ Local rectifier control and monitoring via onboard CXC. Certification:. ..........................N/A . Standards:..............................N/A . Drawing References:..............020-584-20; Bill of Materials 020- 584-04: Assembly 020-584-05: Schematic 020-584-06; Outline 020-584-B2; User Manual List Options: Additional: 0,55; 400 Amp, 16 Position UDC 1; 24VDC, Negative Ground 2; 48VDC 19; 19” Center Mount 23; 23” Center Mount 25; 23” Flush Mount 71; 24VDC Load Disconnect 72; 48VDC Load Disconnect 78; Cordex CXC 80,1; 24VDC Battery Disconnect 80,2; 48VDC Battery Disconnect 82; Jumper, No 48VDC Load Disconnect 83; 600A battery shunt (used with L71/72 and no L80) 84; 600A Load Shunt (used with L80 and no L71/72) 85; 600A shunt (used with L71/72 and L80) 86; 8 breaker positions with front access ground bar) 100; 5A Breaker 101; 10A Breaker 102; 20A Breaker 103; 30A Breaker 104; 40A Breaker 105; 50A Breaker 106; 60A Breaker 107; 70A Breaker 108; 80A Breaker 109; 90A Breaker 110; 100A Breaker 111; 15A Breaker 112; 25A Breaker ® Ground Bar:. .................._x0007_ round: 4x ⅜"-16 tapped holes . G on 1” centers Load returns:.................._x0007_ "-20 tapped holes on ⅝" centers ¼ (1 per breaker) Load Connections:........._x0007_ "-20 tapped holes on ⅝" centers ¼ (1 per breaker) Rectifier Termination:. ...._x0007_ x ⅜"-16 tapped holes on . 2 1" centers Battery Termination:......._x0007_ x ⅜"-16 tapped holes on 2 1" centers Breaker Option:.............._x0007_ M-type mid-trip plug-in breaker, A 5∕16" bullet-style terminals; no alarm jumper wires are required. Selectors:......................._x0007_ attery disconnect and load . B disconnect Alarm:.............................Form C relay contacts via CXC title: 020-584-20 Front Access Distribution Center Document: 020-584-20.vsd DRW: Revision: A Member of The Alpha Group™ date: Jan 19, 2009 sheet: _x000C_