SlideShare a Scribd company logo
1 of 48
Download to read offline
LiebertHPS--PD--272965--20.11.2009
Liebert HPS
High Performance Split Air Conditioner for Mobile Network Access Nodes
Precision Cooling for
Business--Critical Continuity
PRODUCT DOCUMENTATION
HPSE
HPSC
SE_W
Liebert HPS
Liebert HPS---PD---272965---20.11.2009
Introduction
Liebert HPS is the high performance split air conditioner family designed to assure proper environmental conditions inside
technological environments, especially BTS and Node B for Mobile Networks.
It’s composed of the HPSE indoor ceiling mounted module coupled with the HPSC outdoor module.
It’s efficient thanks to the effectiveness air distribution reached through the displacement cooling concept; it’s energy and
space saving thanks to the high efficiency components and the compactness of the innovative free cooling version; it’s ex-
tremely flexible thanks to the possibility of selecting among several versions: Liebert HPS can be configured depending on
the main application drivers (noise level, allowed environmental conditions range etc.) and the desired option (free cooling,
emergency free cooling, heating etc.).
The Liebert HPS family is also available in the HPSW version, made of the SE_W indoor wall mounted moudule coupled with
the HPSC outdoor module.
HPSE ceiling mounted module
coupled with HPSC outdoor unit: the
innovative ceiling mounted installa-
tion and efficiency of displacement
coolingconceptcoupledwiththereli-
ability and quietness of HPSC out-
door unit.
SE_W wall mounted module
coupled with HPSC outdoor unit: the
traditional wall mounted installation
coupled with the reliability and quiet-
ness of HPSC outdoor unit.
Index of Contents
0 -- 0Liebert HPS---PD---272965---20.11.2009
Contents 1 Features and Benefits
2
Model Description and
Selection
3 Mechanical Specifications
4 Control
5 Options
6 Test and Reference Norms
7 Technical Data
8 Dimensional Drawings
9 Installation
The product conforms to European Union
directives 2006/42/EC; 2004/108/EC;
2006/95/EC and 97/23/EC.
Units are supplied complete with a test
certificate and conformity declaration and
control component list.
Liebert HPS units are CE marked as they
comply with the European directives
concerning mechanical, electrical and
electromagnetic safety.
The Quality Management
System of Emerson Network
Power S.r.l. High Performance
Air Conditioning has been
approved by Lloyd's Register
Quality Assurance to the
quality management system
standard ISO 9001:2008.
1 Features and Benefits
1 -- 1Liebert HPS---PD---272965---20.11.2009
Distribute the air in the best way
The HPSE, ceiling mounted indoor unit is thought to send the cold air straightly down, close to
the racks suction area and intakes the hot air out coming from the heat sources, into the cabinet
sides (frontal and lateral).
In this way the mixing effect between conditioner cold air and electronic equipment hot air is
denied resulting in a double beneficial effect: the rack is fed by cold air where it is needed and
the air conditioner treats only the hot air maximizing its efficiency.
Proper temperature inside the racks, high efficiency of the cooling equipment , hot spot absence
in the site: distributing the air in a smart way is very effective.
Save energy and space
The use of the optional freecooling gives the possibility to stop the compressor and use the ex-
ternal fresh air to cool the site: the annual energy absorption, requested to cool the site, goes
sensibly down. The 0---100% fine modulation allows to keep constantly the desired set point in-
side the site.
Noadding module is requested when using the HPSE ceiling mounted indoorunit: theinnovative
rotary freecooling system keeps unchanged the requested space to install the unit.
Use the additional freecooling module to have the wall mounted (SE_W) solution.
Maximize site reliability
Remote nodes need to exchange data continuously, always working at proper environmental
conditions.
Therefore the air conditioner reliability is not an option: it’s a must.
The most modern design and components such as scroll compressor and plug---type fans, heat
exchanger surfaces and airflows generously designed allow the unit to work 24h/day, 365 days.
Maximize the unit reliability selecting the emergency cooling option: in case of main supply fault
the air conditioner is supplied by alternative energy sources like 48 VDC batteries or independent
AC generator.
Start---up quickly and easily the site
Liebert HPS is ceiling mounted (HPSE) or wall mounted (SE_W): 2 rows with screws have to be
used to easily fix the unit to the site ceiling or wall. No internal wiring of the air conditioner is re-
quested thanks to the availability of the fast plug electrical connectors (special on request).
The auto test software checks automatically all the main components operations, speeding up
the site start up procedure.
Choose the cooling unit suitable to your application
Liebert HPS assures optimal air distribution, efficiency, energy saving, reliability, compactness
whatever is its configuration. More stringent requirements in terms of noise level emission and
maximum external working temperature, can be satisfied selecting HPSC advanced version: 45
dB(A) at 3m f.f and 50˚C with internal conditions of 27˚C, 35% R.H. at 1.5m from site floor.
Long piping installations are not anymore a limit: using the “L” condenser version, high perform-
ances are assured also when distance between outdoor and indoor unit is prohibitive.
Respect the environment: ODP, TEWI and . . . noise level
Now days green refrigerants are a standard (low Ozone Depletion Potential)! More than this, the
most effective way to respect the environment is to reduce the energy absorption with a high effi-
ciency refrigerant cycle.
Liebert HPS reach a high EER (Energy Efficiency Ratio) value thanks to the use of large surface
heat exchangers; this effect is maximized by the U---Shape coil used in the evaporating side. The
relevant Total Equivalent Warming Impact (TEWI) value is reduced.
Finally the importance of a low noise level: a different way, not less important, torespect the envir-
onment.
S Optimalracksfeedings
S Highcoolingefficiency
S Minimizetheenergy
consumptionwiththe
mostcompactsolution
S Reliablecomponents
S Emergencyfree
(cooling)system
S Fastplugelectrical
connectors
S Automatictest
start---upsoftware
S HPSCAdvanced
S Lownoiselevel
S Extremeenvironmental
conditions
S Longpiping
S Greenrefrigerants
S Highefficiency
refrigerationcycle
S Lownoiselevel
2 Model Description and Selection
2 -- 1Liebert HPS---PD---272965---20.11.2009
3 654 10987
Cooling Capacity “kW”
(Nominal Cooling Capacity)
1 2
Model Nomenclature / Digit Numbers
_ _ _ _ _ _ _
H P S E 0 6
Split Evaporator Section
(Indoor Unit)
High Performance Unit
CEILING MOUNTED INDOOR UNIT
HPSE 06 --- 14
BASE UNIT EVAPORATOR SECTION
Split air cooled indoor unit
Digits 1, 2, 3, 4, 5, 6
D RAL7035 “bright grey” cabinet
Digit 7 --- Emergency cooling (EFC)
0 = No emergency cooling
1 = Emergency cooling through 48Vdc fan (*)
2 = Kit for connection to external inverter (*)
(*) Option possible only if digit 9 = 1, 2, 3, or 4.
Digit 8 --- Main power supply and electric heating (*)
0 = 230V / 1Ph / 50Hz (no electric heating) --- HPS 06
400V / 3Ph / 50Hz (no electric heating) --- HPS 08---14
1 = 230V / 1Ph / 50Hz (with electric heating) --- HPS 06
400V / 3Ph / 50Hz (with electric heating) --- HPS 08---14
(*) Power supply must be the same as per digit 5 of HPSC unit.
Digit 9 --- Fresh air freecooling (FC)
0 = No freecooling
1 = FC circular holes --- modulating damper
2 = FC rectangular holes --- modulating damper
3 = FC circular holes --- fast return damper
4 = FC rectangular holes --- fast return damper
Digit 10 ---Microprocessor control
1 = Control (no display)
Plug for display available on indoor unit
2 = Control + remote display
Remote wallmount display
3 = Connectivity (*) control (no display)
Available plugs: LAN, remote display and graphic display
4 = Connectivity (*) control + remote display
Available plugs: LAN, remote display and graphic display
5 = Connectivity (*)control+ graphicdisplay and language SetL1
Available plugs: LAN, remote display and graphic display
6 = Connectivity (*)control+ graphicdisplay and language SetL2
Available plugs: LAN, remote display and graphic display
(*) To create LAN choose the Connectivity control and select the optional LAN
cable.
Language set L1: GB, F, I, D, E, P, NL, S.
Language set L2: GB, PL, CZ , H, RUS, TK.
Digit 11 ---Air filter
0 = G3
1 = G4
2 = G3 (indoor air) + clogged filter pressure switch (indoor air)
3 = G4 (indoor air) + clogged filter pressure switch (indoor air)
Digit 12 ---Packing
0 = Cardboard and pallet
C = Cardboard and wooden crate
S = Seaworthy
Digit 13 ---Free
0 = Free option always
Digit 14 ---Evaporator coil
0 = Standard aluminium evaporator fins
1 = Epoxy coated evaporator fins
Digit 15 ---Free
0 = Free option always
Digit 16 ---Free
0 = Free option always
Digit 17 ---Special requirements
0 = None
X = Special
Model Description and Selection
2 -- 2Liebert HPS---PD---272965---20.11.2009
Model Nomenclature / Digit Numbers
4 109871 2
S E 0 6 W
Cooling Capacity “kW”
(Nominal Cooling Capacity)
Wall Mounted Unit
3 5
WALL MOUNTED INDOOR UNIT
Split Evaporator Section
(Indoor Unit)
6 _ _ _ _ _ _ _
SE 06 --- 14W
BASE UNIT EVAPORATOR SECTION
Split air cooled indoor unit
Digits 1, 2, 3, 4
D RAL7035 “bright grey” cabinet
D Air flow sensor
Digit 5
W =Wall mounted
Digit 6 --- Free
0 = Free option always
Digit 7 --- Emergency cooling (EFC)
0 = No emergency cooling
A = Emergency cooling through 48Vdc fan (*)
2 = Kit for connection to external inverter (*)
B = Emergency cooling through 24Vdc fan (*)
(*) Option possible only if digit 9 = 1, 2, 3, or 4.
Digit 8 --- Main power supply and electric heating (*)
0 = 230V / 1Ph / 50Hz (no electric heating) --- HPSW 06
400V / 3Ph / 50Hz (no electric heating) --- HPSW 08---14
1 = 230V / 1Ph / 50Hz (with electric heating) --- HPSW 06
400V / 3Ph / 50Hz (with electric heating) --- HPSW 08---14
(*) Power supply must be the same as per digit 5 of HPSC unit.
Digit 9 --- Fresh air freecooling (FC)
0 = No freecooling
1 = FC circular holes --- modulating damper
2 = FC rectangular holes --- modulating damper
3 = FC circular holes --- spring return damper
4 = FC rectangular holes --- spring return damper
Digit 10 ---Microprocessor control
A = Control + remote display
Remote wallmount display
B = Control + remote display + connection cables for stand---by
Remote wallmount display inclusive of connectors cable
C = Control + graphic display and language Set L1 (*)
D = Control + graphic display and language Set L2 (*)
(*) Language set L1: GB, F, I, D, E, P, NL, S.
Language set L2: GB, PL, CZ , H, RUS, TK.
Digit 11 ---Air filter
0 = G3
1 = G4
2 = G3 + clogged filter pressure switch
3 = G4 + clogged filter pressure switch
Digit 12 ---Packing
0 = Pallet + heavy cardboard
C = Cardboard and wooden crate
S = Seaworthy
Digit 13 ---Refrigerant
1 = R407C
Digit 14 ---Evaporator coil
0 = Standard aluminium evaporator fins
1 = Epoxy coated evaporator fins
Digit 15 ---Free
0 = Free option always
Digit 16 ---Free
0 = Free option always
Digit 17 ---Special requirements
0 = None
X = Special
Model Description and Selection
2 -- 3Liebert HPS---PD---272965---20.11.2009
Model Nomenclature / Digit Numbers
64 109871 2
H P S C 0 6
Cooling Capacity “kW”
(Nominal Cooling Capacity)
Split Condenser Section
(Outdoor Unit)
High Performance Unit
3 5
OUTDOOR UNIT
HPSC 06 --- 14
BASE UNIT CONDENSER SECTION
Split air cooled outdoor unit
Digits 1, 2, 3, 4, 5, 6
D Scroll compressor
D R407C --- 230V / 1Ph / 50Hz (6kW)
D R407C --- 400V / 3Ph / 50Hz (8---14kW)
D RAL7035 ”bright grey” cabinet
Digit 7 --- Configuration
0 = Base (no sight glass filter, ON---OFF fan speed control)
A = Advanced
D Sight glass filter, modulating fan speed control, lower
noise, higher external temperature
L = Long piping application
Digit 8 --- Condenser coil
0 = Standard aluminium fins
1 = Epoxy coated condenser fins
2 = Standard aluminium fins with protection grilles
3 = Epoxy coated condenser fins with protection grilles
Digit 9 --- Packing
0 = Pallet + heavy cardboard
C = Cardboard and wooden crate
S = Seaworthy
Digit 10 ---Special requirements
0 = None
X = Special
3 Mechanical Specifications
3 -- 1Liebert HPS---PD---272965---20.11.2009
Refrigerant circuit
The compressor, located in the moto---condensing section, is hermetic, scroll type, complete with
internal protection against overheating. It is housed in a compartment separated from the air flow,
protected by an insulated panel, accessible from the front side for complete maintenance.
A crankcase heater maintains a minimum refrigerant temperature to allow reliable start---up and
operation even in very cold climate. Depending on the configuration a capillary or a thermostatic
expansion valve, filter dryer and sight glass, low pressure and high pressure switches and two
access valves complete the refrigerant circuit.
Evaporating section
The evaporator section consists of a coil with copper
tubes and aluminium fins, with a large face area in or-
der to increase the SHR (Sensible Heat Ratio) and op-
timize the EER (Energy Efficiency Ratio).
The U---shape coil in the ceiling mounted unit, in-
creases the heat exchange efficiency.
A galvanized steel condensate drain tray
(10/10mm thick) is provided.
Depending on unit version, evaporating fan(s), all dir-
ect driven, can be axial (HPSE ceiling mounted, cool-
ing only), centrifugal (SE_W only cooling) or centrifu-
gal backward curved (HPSE ceiling or SE_W wall
mounted, Freecooling and Emergency Freecooling).
Fans are statically and dynamically balanced with
self---lubricated bearings, equipped with an airflow
sensor as standard to provide an alarm in case of low
airflow.
Condensing section
A wide surface condensing coil is provided. It is de-
signed in copper tubes with aluminium fins and sized
to allow operations at least up to up to 45˚C outdoor air temperature.
The ”Advanced” version extends the external high temperature limit to 50˚C in order to satisfy
extreme environmental working conditions. The units are equipped with 6---pole axial fan. The
electrical motor is directly coupled on the motor shaft, with internal thermal protection and IP54.
The innovative design of the impeller allows the maximum efficiency with the minimum noise.
In Liebert HPS standard, the condenser fan is activated togeth-
er with the compressor; a simple and valid solution where the re-
quired noise level is not extremely low (50 dB(A) at 2m f.f), where
the temperate climate doesn’t required to work in extremely low
environment conditions (10˚C), where using the freecooling you
can save your energy and go down to ---30˚C.
In the ”Advanced” Liebert HPS, the condensing fan speed is
smoothly regulated by a modulating control; it is the ideal solu-
tion if the freecooling is not allowed and the air conditioner is re-
quired to work in mechanical mode down to ---30˚C; it’s a must
where extremely low noise level is required. Keeping the Advan-
ced performances, the long piping version extends the allowed
distance between the evaporating and condensing unit (see Fig.
22, Fig. 23, Fig. 24 and Fig. 25).
Filtering section
The filter section is placed vertically, before the evaporating coil and provides filtration of the in-
ternal ambient and the fresh air to obtain the required degree of air cleanliness in the room. The
filter can be removed from the bottom of the unit (indoor side) simply opening the relevant panel
and unlocking the support brackets. The standard filter class is G3, according to Eurovent EU4/5
standard. A metallic pre---filter, enclosed in the freecooling air intake grill (accessory), protect the
fresh air filter.
S Scrollcompressor
S Crankcaseheater
S Filterdryerandsight
glass
S Highefficiencyfans
andheatexchangers
S Upto45_Cexternal
temperatureand
50dB(A)
S HPSCadvanced:
upto50_Cand
48.5dB(A)
S HPSClongpiping:
upto50mdistance
betweenevaporating
andcondensingunit
S Ambient:G3
S Freshair:pre---filter
HPSE
(CEILING)
SE_W
(WALL)
HPSC
Mechanical Specifications
3 -- 2Liebert HPS---PD---272965---20.11.2009
Cabinet
Liebert HPS frame consists of riveted steel panels, treated with powder coating colour as stand-
ard (RAL7035). The evaporating unit can be placed ceiling mounted (HPSE) or wall mounted
(SE_W). In the HPSE, air inlet is located in the 3 side panels and the air supply is done from the
bottom section, through an integrated grille.
In the SE_W, air inlet is located at unit frontal bottom side and air supply is from unit top.
The motor---condensing unit (HPSC) is designed to be installed outdoor and resist to worst
weather conditions.
The thermo---acoustic insulation of the panels is 10 mm thick, mineral wool type, density 70 kg/-
m3.
The motor---condensing unit takes the external air from the rear and discharge it on the front sec-
tion. A frontal metal safety grid prevents contact with the fan.
The insulation of the panels is made by a self---extinguishing material, specified as class V1 in re-
lation to its fire proof properties.
Electrical panel
The electrical panel of the indoor unit is housed in easily accessible panel: it includes the circuit
breaker for the AC power line, the circuit breaker for the optional DC power line and the electronic
board. An external main switch is available on the unit side as standard.
Thanks to the fast plug connectors (special on request), no internal wiring is needed: AC power
line, DC power line, power supply for the condenser, general warning and alarm, display connec-
tion, optional LAN connection are available on the side of the evaporating unit. The electrical
board is built in accordance with EN 60204---1 recommendations.
A single phase transformer supplies with 24 VAC the electronic control and the secondary circuit
with maximum safety; in Liebert HPS with optional 48 VDC emergency freecooling system, the
control is directly fed by the 48 VDC supply source.
Automatic restart is provided after a power failure.
The outdoor HPSC condenser unit receives main power supply fromthe indoorunit, togetherwith
the control signals collected in a dedicated weather---proof terminal block.
Operational limits
HPS
HPS 06
06
Advanced
Long piping
08
08 to 14
Advanced
Long piping
Power supply voltage 230Vac ±10% / 1Ph / 50Hz 400Vac ±10% / 3Ph / 50Hz
Outdoor
working conditions
from
10 ˚C
(mechanical mode)
---30 ˚C
10 ˚C
(mechanical mode)
---30 ˚C
---30 ˚C
(freecooling mode)
---30 ˚C
(freecooling mode)
to 47 ˚C 51 ˚C 45 ˚C 50 ˚C
Indoor
working conditions
(*)
from 24 ˚C, 30% R.H. and 24 ˚C, 80% R.H.
to 35 ˚C, 40% R.H.
34 ˚C,
40% R.H. 30 ˚C, 40% R.H.
Storage conditions
---40 ˚C, 5% R.H.
55 ˚C, 90% R.H.
(*) Conditions referred to indoor unit (HPSE) air intake section.
S Nointernalwiring
withthefastplug
connectors
accessories
S Evaporatingside:
ceilingmounted
S Condensingside:
worstweather
conditionsresistance
Mechanical Specifications
3 -- 3Liebert HPS---PD---272965---20.11.2009
HPSW
HPSW 06 08 10 13 14
Power supply voltage
230V ±10% /
1Ph / 50Hz 400V ±10% / 3Ph + N + PE / 50Hz
Outdoor
working conditions
from ---30 ˚C
to 52 ˚C 49.5 ˚C 50.5 ˚C 49 ˚C
Indoor
working conditions (*)
from
22 ˚C, 30% R.H.,
80% R.H. 20 ˚C, 30% R.H., 80% R.H.
to 30 ˚C, 40% R.H.
Storage conditions
---40 ˚C, 5% R.H.
55 ˚C, 90% R.H.
(*) --- The min. indoor temperature is referred to 30% of indoor relative humidity and to the min. outdoo temperat-
ure; for higher relative humidity and/or outdoor temperatures, the min. indoor temperature is higher than the
table data.
The max. indoor temperature is referred to outdoor temperature of 35˚C; for higher indoor relative humidities
and/or outdoor temperatures, the max indoor temperature is lower than the table data.
Mechanical Specifications
3 -- 4Liebert HPS---PD---272965---20.11.2009
Fig. 1 --- HPSE ceiling mounted --- Operating diagram (without freecooling)
ITEM DESCRIPTION
1 Evaporating coil
2 Fan
Fig. 2 --- HPSE ceiling mounted --- Operating diagram (with freecooling)
ITEM DESCRIPTION
1 Fresh air filter
2 Evaporating coil
3 Fan
4 Fan nozzle
5 Freecooling damper
TOP VIEW
(WITHOUT PANEL)
CROSS
SECTION
Return air
Treated air
Return
air
1 2
Return
air
Return air
Freecooling air
TOP VIEW
(WITHOUT PANEL)
CROSS
SECTION
Treated air
Freecooling
air
12 3 45
Mechanical Specifications
3 -- 5Liebert HPS---PD---272965---20.11.2009
Fig. 3 --- SE_W wall mounted --- Operating diagram
8
5
SIDE
AIR
RETURN
AIR
CONDITIONED
OUTSIDE
AIR
SIDE
AIR
CONDITIONED
AIR
RETURN
With
freecooling option
Without
freecooling option
6
4
3
2
1
7
2
7
5
3
8
4
ITEM DESCRIPTION
1 Freecooling damper
2 Air filter
3 Evaporator coil
4 Evaporator unit fan
5 Air discharge duct
6 Damper motor
7 Air suction grille
8 Electrical panel evaporating unit
4 Control
4 -- 1Liebert HPS---PD---272965---20.11.2009
Main features
The main board is housed in the electrical panel
of the HPSE and can be connected to the
remote display, to be installed in the
container/room (connection cable is included in
the remote display option).
D The user interface (option) is the 3---digit
back---lit display showing parameter values
and relevant symbols/codes in a tree menu.
It features navigation push buttons and
status leds.
D General warning and general alarm signals
are available: both of them activate a visual indicator in the optional display.
D Input for remote On---Off and volt---free contacts for simple remote monitoring of general
warning and alarms are available.
D The self ---test function automatically activates/deactivates the main components (evaporator
fan, compressor, freecooling damper, heaters, alarms) without changing the pre---set
parameters, to easily start---up and commission the unit.
No skilled personnel are requested (*).
D All settings are protected through a 3---Level password system (*).
D Automatic restart is provided after a power failure.
(*) The Remote display is required to activate the function.
Technical data
D Power supply: 24 Vac / 24 Vdc / 48 Vdc. . . . . . . . . . . . . . . . . .
D E2prom: 64 Kbit. . . . . . . . . . . . . . . . . . . . . . .
D Eprom/Flash memory: 2 or 4 Mbit. . . . . . . . . . .
D RAM memory space: 256 Kbit. . . . . . . . . . . .
D Analogue Input: 1 x Analogue 0---10V. . . . . . . . . . . . . . . .
2 x Analogue 0---5V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D Digital Input: 3 x PTC input. . . . . . . . . . . . . . . . . . .
5 x Flexible Digital multi input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D Analogue Output: 2 x Analogue 0---10V. . . . . . . . . . . . . . .
D Digital output: 3 x relay high power output. . . . . . . . . . . . . . . . . .
2 x relay 24Vac/48Vdc output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 x relay low power output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 x open collector 12Vdc output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D Time and date function buffered by LI---battery
D Hirobus LAN connectors (optional): 3 RJ45 sockets (to and from LAN connected units,
remote display)
D Hironet connectors: 1 RJ9 socket for RS485 (direct connection to. . . . . . . . . . . . .
proprietary supervision)
D Hiromatic E display (optional)
D SMM mobile phones communications via SMS (optional)
5 Options
5 -- 1Liebert HPS---PD---272965---20.11.2009
Emergency cooling
The unit is optionally equipped with an emergency cooling system that allows to ventilate or to
cool through external fresh air the site in case of main electrical supply fault.
For this purpose the evaporating fan section, the control, and the free cooling damper are sup-
plied in 48 VDC power supply (from rectifier in normal mode, from batteries in emergency mode).
This option guarantees the air circulation inside the site and if the control recognizes the proper
external temperature to run the freecooling mode, the damper will open to fresh the site and get
the required set point. The emergency cooling system is also available in 230 VAC.
The compressor and the condenser fan are supplied by standard AC power.
Heating
The heating option include electric heaters (1.5 kW on model 06, 3.0 kW on models 08---10, 4.5
kW on model 12 and 6.0 kW on model 14), located in the air discharge plenum, one stage and
ON---OFF regulation.
A safety thermostat, with manual reset, prevents from reaching dangerous temperatures.
Freecooling
The freecooling system consists of a damper controlled and moved from a AC servomotor
(48VDC supplied in the emergency version).
The system allows a 0---100% modulating freecooling in order to respect the desired set point.
The exhaust air is discharged outdoor through an overpressure damper mounted on the wall and
available as accessory. The control allows the unit torun in freecooling mode when the difference
between the indoor and outdoor air temperature reaches the required value to get the nominal
cooling capacity. In emergency situation, the freecooling is allowed at a lower difference between
the indoor and outdoor air temperature, in order to use the external fresh air as much as possible.
In the HPSE ceiling mounted version, the innovative rotary system allows the air conditioner to
be equipped with the freecooling system without any adding module, maintaining the standard
unit dimensions.
Connectivity
The possibility to create a LAN is available selecting the “Connectivity” control version and con-
necting two or more units through the Hirobus cable (optional). Functions provided include
stand---by (in case of failure or overload of the unit in operation, the second one starts automatic-
ally), automatic rotation and cascade (sharing of the total load among several units).
Special filtration
Optional high---level filtration can be reached.
A clogged filter system can be supplied to advise when the indoor air filter is dirty.
Package
Standard packing consists of a wooden pallet and cardboard box. Polythene foam protects the
units’ painted surfaces. On request, a cardboard box with an additional wooden crate or wooden
case for sea transport can be supplied.
Corrosive environments protection
The condenser coil and/or evaporator coils are available with aluminium fins coated by epoxy
film, to protect from aggressive environmental conditions.
Long piping installation
Select the “L” condenser option to allow long piping installations between outdoor and indoor
units: up to50 m of equivalent length with up to20 m of height level difference, being the condens-
ing unit below or above the evaporating one, doesn’t matter.
The “L” condenser version includes also all features provided within condenser “Advanced” ver-
sion (”A”).
S Uninterruptible
ventilation
S Freecoolingevenin
emergencyconditions
S ON---OFFcontrol
S Safetythermostat
S Compactsystem
S 0---100% modulation
S G4filter
S Cloggedfilter
S Cardboardbox
S Woodencrate
S LANmanagement
S Epoxycoatedcoils
S Up to 50m equivalent
length
6 Test and Reference Norms
6 -- 1Liebert HPS---PD---272965---20.11.2009
Safety
Liebert HPS units are designed, manufactured and tested according to the European Union dir-
ectives:
D 2006/42/EC;
D 2004/108/EC;
D 2006/95/EC;
D 97/23/EC.
Electrical Board
Design and manufacturing is compliant with EN 60204---1.
Electro---Magnetic compatibility (EMC)
Liebert HPS complies with the following EMC standards:
D EN 50081---1, Emission (“Generic emission standard, Part 1: Residential, commercial and
light industry, Jan 1992”)
D EN 50082---2, Immunity (“Generic immunity standard, Part 2: Industrial environment,
Mar 1995”).
Mark
Each unit is supplied complete with individual test certificate and a declara-
tion of conformity to the European Union directives. The units are marked
“CE”.
Quality
The Quality Management System of Emerson Network Power S.r.l.
High Performance Air Conditioning has been approved by Lloyd’s Re-
gister Quality Assurance to the quality management system standard ISO
9001:2008.
7 Technical Data
7 -- 1Liebert HPS---PD---272965---20.11.2009
Tab. 1 --- HPSE + HPSC (No freecooling version)
MODEL: HPS 06 08
Air supply --- Downflow
Main power supply --- 230V±10%/1Ph/50Hz 400V±10%/3Ph+N+PE/50Hz
PERFORMANCE
Total cooling capacity (1)
Sensible cooling capacity (1)
Compressor --- AC power input (1)
Compressor --- AC operative current (OA) (1)
Compressor --- AC max current (FLA)
Compressor --- AC starting current (LRA)
Condenser fan --- AC power input (1)
Condenser fan --- AC max. power input
Condenser fan --- AC operative current (OA) (1)
Condenser fan --- AC max. current (FLA)
Condenser fan --- AC start---up current
Evaporator fan --- AC power input (1)
Evaporator fan --- AC operative current (OA) (1)
Evaporator fan --- AC max. current (FLA) (2)
Evaporator fan --- AC start---up current
Evaporator air flow
Condenser max. air flow
Outdoor Sound Pressure Level (3)
Indoor Sound Pressure Level (3)
Max. ambient temperature (4)
kW
kW
kW
A
A
A
kW
kW
A
A
A
kW
A
A
A
m3/h
m3/h
dB(A)
dB(A)
_C
6.4
6.4
1.58
7.6
11.4
47.0
0.08
0.08
0.6
1.4
1.6
0.18
0.8
1.0
1.3
1510
2170
50
58
47
8.2
8.2
2.18
3.9
5.1
32.0
0.10
0.10
0.7
1.4
1.6
0.35
1.5
2.0
2.7
2440
1920
50
62.5
45
REFRIGERATION CIRCUITS
Compressor --- type / quantity
Refrigerant
Expansion device
Evaporator coil --- tubes / fins material
Condenser coil --- tubes / fins material
---
---
---
---
---
Scroll / 1
R407C
Capillary
Copper / Aluminium
Copper / Aluminium
AIR FILTRATION
Main air filter --- quantity / type
Efficiency (CEN---EU)
---
---
3 / Panel filters
G3
Filters dimensiond (DX side) mm 597 / 267 / 10
EVAPORATOR FAN
Quantity / Type / Poles --- 1 / Axial / 4
Driven / Motor protection --- Direct / IP44 Direct / IP54
CONDENSER FAN
Quantity / Type / Poles --- 1 / Axial / 6
Driven / Motor protection --- Direct / IP54
Control system --- Single speed
ELECTRIC HEATING
Type / Steps --- Wires / 1
Heating capacity kW 1.5 3.0
Heating --- max. current A 6.5
CABINET
Frame --- Galvanised steel
Painting --- Polyester --- RAL7035
OVERALL DIMENSIONS
Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390
Width / Height / Depth (HPSE indoor unit) mm 800 / 310 / 800
Weight (HPSC outdoor unit) kg 80 82
Weight (HPSE indoor unit) kg 50 53
Notes:
(1) – Indoor reference conditions: 30˚C / 35% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply.
(2) – Values referred to nominal speed (factory set).
(3) --- Measured with max. outdoor temperature at 2 m from the unit, in free field conditions.
(4) --- Maximum outdoor temperature referred to 30˚C / 35% R.H. air intake.
Technical Data
7 -- 2Liebert HPS---PD---272965---20.11.2009
Tab. 2 --- HPSE + HPSC (Freecooling and AC emergency freecooling versions)
MODEL: HPS 06 08
Air supply --- Downflow
Main power supply --- 230V±10% / 1Ph / 50Hz 400V±10%/3Ph+N+PE/50Hz
Emergency power supply --- 230V±10% / 1Ph / 50Hz
PERFORMANCE
Total cooling capacity (1)
Sensible cooling capacity (1)
Compressor --- AC power input (1)
Compressor --- AC operative current (OA) (1)
Compressor --- AC max current (FLA)
Compressor --- AC starting current (LRA)
Condenser fan --- AC power input (1)
Condenser fan --- AC max. power input
Condenser fan --- AC operative current (OA) (1)
Condenser fan --- AC max. current (FLA)
Condenser fan --- AC start---up current
Evaporator fan --- AC power input (1)
Evaporator fan --- AC operative current (OA) (1)
Evaporator fan --- AC max. current (FLA) (2)
Evaporator fan --- AC start---up current
Evaporator air flow
Freecooling air flow
Condenser max. air flow
Outdoor Sound Pressure Level (3)
Indoor Sound Pressure Level (3)
Max. ambient temperature (4)
kW
kW
kW
A
A
A
kW
kW
A
A
A
kW
A
A
A
m3/h
m3/h
m3/h
dB(A)
dB(A)
_C
5.9
5.9
1.57
7.3
11.4
47.0
0.08
0.08
0.6
1.4
1.6
0.14
0.6
0.6
1.2
1390
820
2170
50
59
48
8.3
8.3
2.18
3.9
5.1
32.0
0.10
0.10
0.7
1.4
1.6
0.39
2.8
2.4
5.3
2020
2040
1920
50
62.5
45
REFRIGERATION CIRCUITS
Compressor --- type / quantity
Refrigerant
Expansion device
Evaporator coil --- tubes / fins material
Condenser coil --- tubes / fins material
---
---
---
---
---
Scroll / 1
R407C
Capillary
Copper / Aluminium
Copper / Aluminium
AIR FILTRATION
Main air filter --- quantity / type
Efficiency (CEN---EU)
---
---
3 / Panel filters for DX side --- 1 / Plated panel filter for FC side
G3
Filters dimensiond (DX side) mm 597 / 267 / 10 697 / 332 / 10
Filters dimensiond (FC side) mm 580 / 300 / 50 680 / 365 / 50
EVAPORATOR FAN
Quantity / Type / Poles --- 1 / Plug / 4
Driven / Motor protection --- Direct / IP44 Direct / IP54
CONDENSER FAN
Quantity / Type / Poles --- 1 / Axial / 6
Driven / Motor protection --- Direct / IP54
Control system --- Single speed
ELECTRIC HEATING
Type / Steps --- Wires / 1
Heating capacity kW 1.5 3.0
Heating --- max. current A 6.5
CABINET
Frame --- Galvanised steel
Painting --- Polyester --- RAL7035
OVERALL DIMENSIONS
Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390
Width / Height / Depth (HPSE indoor unit) mm 800 / 310 / 800 900 / 375 / 900
Weight (HPSC outdoor unit) kg 80 82
Weight (HPSE indoor unit) kg 55 63
Notes:
(1) – Indoor reference conditions: 30˚C / 35% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply.
(2) – Values referred to nominal speed (factory set).
(3) --- Measured with max. outdoor temperature at 2 m from the unit, in free field conditions.
(4) --- Maximum outdoor temperature referred to 30˚C / 35% R.H. air intake.
Technical Data
7 -- 3Liebert HPS---PD---272965---20.11.2009
Tab. 3 --- HPSE + HPSC (Freecooling and DC emergency freecooling versions)
MODEL: HPS 06 08
Air supply --- Downflow
Main power supply --- 230V±10% / 1Ph / 50Hz 4000V±10%/3Ph+N+PE/5Hz
Emergency power supply --- 48 VDC
PERFORMANCE
Total cooling capacity (1)
Sensible cooling capacity (1)
Compressor --- AC power input (1)
Compressor --- AC operative current (OA) (1)
Compressor --- AC max current (FLA)
Compressor --- AC starting current (LRA)
Condenser fan --- AC power input (1)
Condenser fan --- AC max. power input
Condenser fan --- AC operative current (OA) (1)
Condenser fan --- AC max. current (FLA)
Condenser fan --- AC start---up current
Evaporator fan --- DC power input (1)
Evaporator fan --- DC operative current (OA) (1)
Evaporator fan --- DC max. current (FLA) (2)
Evaporator fan --- DC start---up current
Evaporator air flow
Freecooling air flow
Condenser max. air flow
Outdoor Sound Pressure Level (3)
Indoor Sound Pressure Level (3)
Max. ambient temperature (4)
kW
kW
kW
A
A
A
kW
kW
A
A
A
kW
A
A
A
m3/h
m3/h
m3/h
dB(A)
dB(A)
_C
5.9
5.9
1.57
7.3
11.4
47.0
0.08
0.08
0.6
1.4
1.6
0.10
2.6
2.6
0.1
1350
820
2170
50
57
48
8.2
8.2
2.17
3.9
5.1
32.0
0.10
0.10
0.7
1.4
1.6
0.28
5.8
9.6
0.1
1910
2040
1920
50
62
45
REFRIGERATION CIRCUITS
Compressor --- type / quantity
Refrigerant
Expansion device
Evaporator coil --- tubes / fins material
Condenser coil --- tubes / fins material
---
---
---
---
---
Scroll / 1
R407C
Capillary
Copper / Aluminium
Copper / Aluminium
AIR FILTRATION
Main air filter --- quantity / type
Efficiency (CEN---EU)
---
---
3 / Panel filters for DX side --- 1 / Plated panel filter for FC side
G3
Filters dimensiond (DX side) mm 597 / 267 / 10 697 / 332 / 10
Filters dimensiond (FC side) mm 580 / 300 / 50 680 / 365 / 50
EVAPORATOR FAN
Quantity / Type / Poles --- 1 / Plug / ---
Driven / Motor protection --- Direct / IP42 Direct / IP20
CONDENSER FAN
Quantity / Type / Poles --- 1 / Axial / 6
Driven / Motor protection --- Direct / IP54
Control system --- Single speed
ELECTRIC HEATING
Type / Steps --- Wires / 1
Heating capacity kW 1.5 3.0
Heating --- max. current A 6.5
CABINET
Frame --- Galvanised steel
Painting --- Polyester --- RAL7035
OVERALL DIMENSIONS
Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390
Width / Height / Depth (HPSE indoor unit) mm 800 / 310 / 800 900 / 375 / 900
Weight (HPSC outdoor unit) kg 80 82
Weight (HPSE indoor unit) kg 55 63
Notes:
(1) – Indoor reference conditions: 30˚C / 35% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply.
(2) – Values referred to nominal speed (factory set).
(3) --- Measured with max. outdoor temperature at 2 m from the unit, in free field conditions.
(4) --- Maximum outdoor temperature referred to 30˚C / 35% R.H. air intake.
Technical Data
7 -- 4Liebert HPS---PD---272965---20.11.2009
Tab. 4 --- HPSE + HPSC Advanced/Long piping (No freecooling version)
MODEL: HPS ADVANCED/LONG PIPING 06 08 10 12 14
Air supply --- Downflow
Main power supply ---
230V±10% /
1Ph / 50Hz 400V±10% / 3Ph+N+PE / 50Hz
PERFORMANCE
Total cooling capacity (1)
Sensible cooling capacity (1)
Compressor --- AC power input (1)
Compressor --- AC operative current (OA) (1)
Compressor --- AC max current (FLA)
Compressor --- AC starting current (LRA)
Condenser fan --- AC power input (1)
Condenser fan --- AC max. power input
Condenser fan --- AC operative current (OA) (1)
Condenser fan --- AC max. current (FLA)
Condenser fan --- AC start---up current
Evaporator fan --- AC power input (1)
Evaporator fan --- AC operative current (OA) (1)
Evaporator fan --- AC max. current (FLA) (2)
Evaporator fan --- AC start---up current
Evaporator air flow
Condenser max. air flow
Outdoor Sound Pressure Level (3)
Indoor Sound Pressure Level (3)
Max. ambient temperature (4)
kW
kW
kW
A
A
A
kW
kW
A
A
A
kW
A
A
A
m3/h
m3/h
dB(A)
dB(A)
_C
6.4
6.4
1.73
8.0
11.4
47.0
0.07
0.24
0.6
1.4
1.6
0.18
0.8
1.0
1.3
1510
2970
48.5
58
51
8.1
8.1
2.23
4.0
5.1
32.0
0.10
0.24
0.7
1.4
1.6
0.35
1.5
2.0
2.7
2440
2970
48.5
62.5
50
10.0
10.0
3.06
5.5
7.0
46.0
0.22
0.48
1.5
2.8
3.3
0.35
1.5
2.0
2.7
2440
6300
52.5
62.5
50
12.5
12.5
3.75
6.6
10.0
50.0
0.22
0.48
1.5
2.8
3.3
0.34
2.0
2.0
2.7
2770
5675
53.5
64
50
14.6
14.6
4.68
8.6
10.2
63.0
0.28
0.48
1.7
2.8
3.3
0.34
2.0
2.0
2.7
2750
5675
55.0
64
50
REFRIGERATION CIRCUITS
Compressor --- type / quantity
Refrigerant
Expansion device
Evaporator coil --- tubes / fins material
Condenser coil --- tubes / fins material
---
---
---
---
---
Scroll / 1
R407C
Thermostatic expansion valve
Copper / Aluminium
Copper / Aluminium
AIR FILTRATION
Main air filter --- quantity / type
Efficiency (CEN---EU)
---
---
3 / Panel filters
G3
Filters dimensiond (DX side) mm 597 / 267 / 10 697 / 332 / 10
EVAPORATOR FAN
Quantity / Type / Poles --- 1 / Axial / 4
Driven / Motor protection --- Direct / IP44 Direct / IP54
CONDENSER FAN
Quantity / Type / Poles --- 1 / Axial / 6 2 / Axial / 6
Driven / Motor protection --- Direct / IP54
Control system --- Variable speed
ELECTRIC HEATING
Type / Steps --- Wires / 1
Heating capacity kW 1.5 3.0 3.0 4.5 6.0
Heating --- max. current A 6.5 13.0
CABINET
Frame --- Galvanised steel
Painting --- Polyester --- RAL7035
OVERALL DIMENSIONS
Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 920 / 1190 / 390
Width / Height / Depth (HPSE indoor unit) mm 800 / 310 / 800 900 / 375 / 900
Weight (HPSC outdoor unit) kg 80 82 97 103 111
Weight (HPSE indoor unit) kg 50 53 58
Notes:
(1) – Indoor reference conditions: 30˚C / 35% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply.
(2) – Values referred to nominal speed (factory set).
(3) --- Measured with outdoor temperature of 35˚C, at 2 m from the unit, in free field conditions.
(4) --- Maximum outdoor temperature referred to 30˚C / 35% R.H. air intake.
Technical Data
7 -- 5Liebert HPS---PD---272965---20.11.2009
Tab. 5 --- HPSE + HPSC Advanced/Long piping (Freecooling and AC emergency freecooling versions)
MODEL: HPS ADVANCED/LONG PIPING 06 08 10 12 14
Air supply --- Downflow
Main power supply ---
230V ±10%
/ 1Ph / 50Hz 400V±10% / 3Ph+N+PE / 50Hz
Emergency power supply --- 230V±10% / 1Ph / 50Hz
PERFORMANCE
Total cooling capacity (1)
Sensible cooling capacity (1)
Compressor --- AC power input (1)
Compressor --- AC operative current (OA) (1)
Compressor --- AC max current (FLA)
Compressor --- AC starting current (LRA)
Condenser fan --- AC power input (1)
Condenser fan --- AC max. power input
Condenser fan --- AC operative current (OA) (1)
Condenser fan --- AC max. current (FLA)
Condenser fan --- AC start---up current
Evaporator fan --- AC power input (1)
Evaporator fan --- AC operative current (OA) (1)
Evaporator fan --- AC max. current (FLA) (2)
Evaporator fan --- AC start---up current
Evaporator air flow
Freecooling air flow
Condenser max. air flow
Outdoor Sound Pressure Level (3)
Indoor Sound Pressure Level (3)
Max. ambient temperature (4)
kW
kW
kW
A
A
A
kW
kW
A
A
A
kW
A
A
A
m3/h
m3/h
m3/h
dB(A)
dB(A)
_C
5.9
5.9
1.74
8.1
11.4
47.0
0.07
0.24
0.6
1.4
1.6
0.14
0.6
0.7
1.2
1390
820
2970
48.5
59
52
8.3
8.3
2.22
4.0
5.1
32.0
0.10
0.24
0.7
1.4
1.6
0.39
2.8
2.4
5.3
2020
2040
2970
48.5
62.5
50
10.3
10.3
3.06
5.5
7.0
46.0
0.22
0.48
1.5
2.8
3.3
0.39
2.8
2.4
5.3
2020
2040
6300
52.5
62.5
50
12.0
12.0
3.75
6.6
10.0
50.0
0.22
0.48
1.5
2.8
3.3
0.45
2.9
2.4
5.3
2220
2040
5675
53.5
64.5
50
14.1
13.8
4.66
8.5
10.2
63.0
0.28
0.48
1.7
2.8
3.3
0.48
2.4
2.4
5.3
2410
2040
5675
55
66
50
REFRIGERATION CIRCUITS
Compressor --- type / quantity
Refrigerant
Expansion device
Evaporator coil --- tubes / fins material
Condenser coil --- tubes / fins material
---
---
---
---
---
Scroll / 1
R407C
Thermostatic expansion valve
Copper / Aluminium
Copper / Aluminium
AIR FILTRATION
Main air filter --- quantity / type
Efficiency (CEN---EU)
---
---
3 / Panel filters for DX side --- 1 / Plated panel filter for FC side
G3
Filters dimensiond (DX side) mm 597/267/10 697 / 332 / 10
Filters dimensiond (FC side) mm 580/300/50 680 / 365 / 50
EVAPORATOR FAN
Quantity / Type / Poles --- 1 / Plug / 4
Driven / Motor protection --- Direct / IP44 Direct / IP54
CONDENSER FAN
Quantity / Type / Poles --- 1 / Axial / 6 2 / Axial / 6
Driven / Motor protection --- Direct / IP54
Control system --- Variable speed
ELECTRIC HEATING
Type / Steps --- Wires / 1
Heating capacity kW 1.5 3.0 3.0 4.5 6.0
Heating --- max. current A 6.5 13.0
CABINET
Frame --- Galvanised steel
Painting --- Polyester --- RAL7035
OVERALL DIMENSIONS
Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 920 / 1190 / 390
Width / Height / Depth (HPSE indoor unit) mm 800/310/800 900 / 375 / 900
Weight (HPSC outdoor unit) kg 80 82 97 103 111
Weight (HPSE indoor unit) kg 55 63
Notes:
(1) – Indoor reference conditions: 30˚C / 35% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply.
(2) – Values referred to nominal speed (factory set).
(3) --- Measured with outdoor temperature of 35˚C, at 2 m from the unit, in free field conditions.
(4) --- Maximum outdoor temperature referred to 30˚C / 35% R.H. air intake.
Technical Data
7 -- 6Liebert HPS---PD---272965---20.11.2009
Tab. 6 --- HPSE + HPSC Advanced/Long piping (Freecooling and DC emergency freecooling versions)
MODEL: HPS ADVANCED/LONG PIPING 06 08 10 12 14
Air supply --- Downflow
Main power supply ---
230V ±10%
/ 1Ph / 50Hz 400V±10% / 3Ph+N+PE / 50Hz
Emergency power supply --- 48 VDC
PERFORMANCE
Total cooling capacity (1)
Sensible cooling capacity (1)
Compressor --- AC power input (1)
Compressor --- AC operative current (OA) (1)
Compressor --- AC max current (FLA)
Compressor --- AC starting current (LRA)
Condenser fan --- AC power input (1)
Condenser fan --- AC max. power input
Condenser fan --- AC operative current (OA) (1)
Condenser fan --- AC max. current (FLA)
Condenser fan --- AC start---up current
Evaporator fan --- DC power input (1)
Evaporator fan --- DC operative current (OA) (1)
Evaporator fan --- DC max. current (FLA) (2)
Evaporator fan --- DC start---up current
Evaporator air flow
Freecooling air flow
Condenser max. air flow
Outdoor Sound Pressure Level (3)
Indoor Sound Pressure Level (3)
Max. ambient temperature (4)
kW
kW
kW
A
A
A
kW
kW
A
A
A
kW
A
A
A
m3/h
m3/h
m3/h
dB(A)
dB(A)
_C
5.9
5.9
1.74
8.1
11.4
47.0
0.07
0.24
0.6
1.4
1.6
0.10
2.6
2.6
0.1
1350
820
2970
48.5
57
52
8.2
8.2
2.23
4.0
5.1
32.0
0.10
0.24
0.7
1.4
1.6
0.28
5.8
9.6
0.1
1910
2040
2970
48.5
62
50
10.2
10.2
3.06
5.5
7.0
46.0
0.22
0.48
1.5
2.8
3.3
0.28
5.8
9.6
0.1
1910
2040
6300
52.5
62
50
12.0
12.0
3.75
6.6
10.0
50.0
0.22
0.48
1.5
2.8
3.3
0.39
8.1
9.6
0.1
2240
2040
5675
53.5
67
50
14.0
13.7
4.66
8.5
10.2
63.0
0.28
0.48
1.7
2.8
3.3
0.45
9.5
9.6
0.1
2380
2040
5675
55
68.5
50
REFRIGERATION CIRCUITS
Compressor --- type / quantity
Refrigerant
Expansion device
Evaporator coil --- tubes / fins material
Condenser coil --- tubes / fins material
---
---
---
---
---
Scroll / 1
R407C
Thermostatic expansion valve
Copper / Aluminium
Copper / Aluminium
AIR FILTRATION
Main air filter --- quantity / type
Efficiency (CEN---EU)
---
---
3 / Panel filters for DX side --- 1 / Plated panel filter for FC side
G3
Filters dimensiond (DX side) mm 597/267/10 697 / 332 / 10
Filters dimensiond (FC side) mm 580/300/50 680 / 365 / 50
EVAPORATOR FAN
Quantity / Type / Poles --- 1 / Plug / ---
Driven / Motor protection --- Direct / IP42 Direct / IP20
CONDENSER FAN
Quantity / Type / Poles --- 1 / Axial / 6 2 / Axial / 6
Driven / Motor protection --- Direct / IP54
Control system --- Variable speed
ELECTRIC HEATING
Type / Steps --- Wires / 1
Heating capacity kW 1.5 3.0 3.0 4.5 6.0
Heating --- max. current A 6.5 13.0
CABINET
Frame --- Galvanised steel
Painting --- Polyester --- RAL7035
OVERALL DIMENSIONS
Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 920 / 1190 / 390
Width / Height / Depth (HPSE indoor unit) mm 800/310/800 900 / 375 / 900
Weight (HPSC outdoor unit) kg 80 82 97 103 111
Weight (HPSE indoor unit) kg 55 63
Notes:
(1) – Indoor reference conditions: 30˚C / 35% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply.
(2) – Values referred to nominal speed (factory set).
(3) --- Measured with outdoor temperature of 35˚C, at 2 m from the unit, in free field conditions.
(4) --- Maximum outdoor temperature referred to 30˚C / 35% R.H. air intake.
Technical Data
7 -- 7Liebert HPS---PD---272965---20.11.2009
Tab. 7 --- SE_W + HPSC (No freecooling version)
MODEL: HPSW 06 08 10 13 (*) 14
Air supply --- Upflow
Main power supply ---
230V±10% /
1Ph / 50Hz 400V ±10% / 3Ph+N+PE / 50Hz
PERFORMANCE
Total cooling capacity (1)
Sensible cooling capacity (1)
Compressor --- AC power input (1)
Compressor --- AC operative current (OA) (1)
Compressor --- AC max current (FLA)
Compressor --- AC starting current (LRA)
Condenser fan --- AC power input (1)
Condenser fan --- AC max. power input
Condenser fan --- AC operative current (OA) (1)
Condenser fan --- AC max. current (FLA)
Condenser fan --- AC start---up current
Evaporator fan --- AC power input (1)
Evaporator fan --- AC operative current (OA) (1)
Evaporator fan --- AC max. current (FLA) (2)
Evaporator fan --- AC start---up current
Evaporator air flow
Condenser max. air flow
Outdoor Sound Pressure Level (3)
Indoor Sound Pressure Level (3)
Max. ambient temperature (4)
kW
kW
kW
A
A
A
kW
kW
A
A
A
kW
A
A
A
m3/h
m3/h
dB(A)
dB(A)
_C
6.1
5.4
1.75
8.0
11.4
47.0
0.11
0.24
0.8
1.4
1.6
0.26
1.2
1.2
1.8
1510
2970
48.5
55
52
8.3
8.3
2.26
4.0
5.1
32.0
0.10
0.24
0.7
1.4
1.6
0.71
3.2
3.7
7.0
2670
2970
48.5
60
49.5
10.5
10.1
3.08
5.5
7.0
46.0
0.22
0.48
1.5
2.8
3.3
0.71
3.2
3.7
7.0
2670
6300
52.5
60
50.5
13.5
13.2
3.80
6.7
10.0
50.0
0.23
0.48
1.5
2.8
3.3
1.14
4.8
7.2
---
3950
5675
53.5
62
49
14.7
13.6
4.76
8.7
10.2
63.0
0.28
0.48
1.7
2.8
3.3
1.14
4.8
7.2
---
3950
5675
55.0
62
49
REFRIGERATION CIRCUITS
Compressor --- type / quantity
Refrigerant
Expansion device
Evaporator coil --- tubes / fins material
Condenser coil --- tubes / fins material
---
---
---
---
---
Scroll / 1
R407C
Thermostatic expansion valve
Copper / Aluminium
Copper / Aluminium
AIR FILTRATION
Main air filter --- quantity / type
Efficiency (CEN---EU)
---
---
1 / Pleated
G3
Filters dimension mm 740/230/48 946 / 300 / 60
EVAPORATOR FAN
Quantity / Type / Poles --- 2 coupled (single motor) / Centrifugal / 4
2 (2 motors)
/ Centrifugal
/ 4
Driven --- Direct
CONDENSER FAN
Quantity / Type / Poles --- 1 / Axial / 6 2 / Axial / 6
Driven / Motor protection --- Direct / IP54
Control system --- Variable speed
ELECTRIC HEATING
Type / Steps --- Tube / 1 Wires / 1
Heating capacity kW 3.0 6.0
Heating --- max. current A 6.5 8.7
CABINET
Frame --- Galvanised steel
Painting --- Polyester --- RAL7035
OVERALL DIMENSIONS
Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 920 / 1190 / 390
Width / Height / Depth (SE_W indoor unit) mm 800/310/800 1100 / 395 / 1095
Weight (HPSC outdoor unit) kg 80 82 97 103 111
Weight (SE_W indoor unit) kg 54 110 120
Notes:
(1) – Indoor reference conditions: 27˚C / 47% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply.
(2) – Values referred to nominal speed (factory set).
(3) --- Measured with outdoor temperature of 35˚C, at 2 m from the unit, in free field conditions.
(4) --- Maximum outdoor temperature referred to 27˚C / 47% R.H. air intake.
(*) --- HPSW 13 is composed by SE 13W + HPSC 12.
Technical Data
7 -- 8Liebert HPS---PD---272965---20.11.2009
Tab. 8 --- SE_W + HPSC (Freecooling and AC emergency freecooling versions)
MODEL: HPSW 06 08 10 13 (*) 14
Air supply --- Upflow
Main power supply ---
230V ±10%
/ 1Ph / 50Hz 400V ±10% / 3Ph+N+PE / 50Hz
Emergency power supply --- 230V ±10% / 1Ph / 50Hz
PERFORMANCE
Total cooling capacity (1)
Sensible cooling capacity (1)
Compressor --- AC power input (1)
Compressor --- AC operative current (OA) (1)
Compressor --- AC max current (FLA)
Compressor --- AC starting current (LRA)
Condenser fan --- AC power input (1)
Condenser fan --- AC max. power input
Condenser fan --- AC operative current (OA) (1)
Condenser fan --- AC max. current (FLA)
Condenser fan --- AC start---up current
Evaporator fan --- AC power input (1)
Evaporator fan --- AC operative current (OA) (1)
Evaporator fan --- AC max. current (FLA) (2)
Evaporator fan --- AC start---up current
Evaporator air flow
Freecooling air flow
Condenser max. air flow
Outdoor Sound Pressure Level (3)
Indoor Sound Pressure Level (3)
Max. ambient temperature (4)
kW
kW
kW
A
A
A
kW
kW
A
A
A
kW
A
A
A
m3/h
m3/h
m3/h
dB(A)
dB(A)
_C
6.1
5.4
1.75
8.0
11.4
47.0
0.11
0.24
0.8
1.4
1.6
0.26
1.2
1.2
1.8
1510
1400
2970
48.5
55
52
8.3
8.3
2.26
4.0
5.1
32.0
0.10
0.24
0.7
1.4
1.6
0.71
3.2
3.7
7.0
2670
2230
2970
48.5
60
49.5
10.5
10.1
3.08
5.5
7.0
46.0
0.22
0.48
1.5
2.8
3.3
0.71
3.2
3.7
7.0
2670
2230
6300
52.5
60
50.5
13.5
13.2
3.80
6.7
10.0
50.0
0.23
0.48
1.5
2.8
3.3
1.14
4.8
7.2
---
3950
3600
5675
53.5
62
49
14.7
13.6
4.76
8.7
10.2
63.0
0.28
0.48
1.7
2.8
3.3
1.14
4.8
7.2
---
3950
3600
5675
55.0
62
49
REFRIGERATION CIRCUITS
Compressor --- type / quantity
Refrigerant
Expansion device
Evaporator coil --- tubes / fins material
Condenser coil --- tubes / fins material
---
---
---
---
---
Scroll / 1
R407C
Thermostatic expansion valve
Copper / Aluminium
Copper / Aluminium
AIR FILTRATION
Main air filter --- quantity / type
Efficiency (CEN---EU)
---
---
1 / Pleated
G3
Filters dimension mm 740/230/48 946 / 300 / 60
EVAPORATOR FAN
Quantity / Type / Poles --- 2 coupled (single motor) / Centrifugal / 4
2 (2 motors)
/ Centrifugal
/ 2
Driven --- Direct
CONDENSER FAN
Quantity / Type / Poles --- 1 / Axial / 6 2 / Axial / 6
Driven / Motor protection --- Direct / IP54
Control system --- Variable speed
ELECTRIC HEATING
Type / Steps --- Tube / 1 Wires / 1
Heating capacity kW 3.0 6.0
Heating --- max. current A 13.1 8.7
CABINET
Frame --- Galvanised steel
Painting --- Polyester --- RAL7035
OVERALL DIMENSIONS
Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 920 / 1190 / 390
Width / Height / Depth (SE_W indoor unit) mm 800/310/1050 1100 / 395 / 1395
Weight (HPSC outdoor unit) kg 80 82 97 103 111
Weight (SE_W indoor unit) kg 62 122 132
Notes:
(1) – Indoor reference conditions: 27˚C / 47% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply.
(2) – Values referred to nominal speed (factory set).
(3) --- Measured with outdoor temperature of 35˚C, at 2 m from the unit, in free field conditions.
(4) --- Maximum outdoor temperature referred to 27˚C / 47% R.H. air intake.
(*) --- HPSW 13 is composed by SE 13W + HPSC 12.
Technical Data
7 -- 9Liebert HPS---PD---272965---20.11.2009
Tab. 9 --- SE_W + HPSC (Freecooling and DC emergency freecooling versions)
MODEL: HPSW 06 08 10 13 (*) 14
Air supply --- Upflow
Main power supply ---
230V ±10%
/ 1Ph / 50Hz 400V ±10% / 3Ph+N+PE / 50Hz
Emergency power supply --- 48 VDC
PERFORMANCE
Total cooling capacity (1)
Sensible cooling capacity (1)
Compressor --- AC power input (1)
Compressor --- AC operative current (OA) (1)
Compressor --- AC max current (FLA)
Compressor --- AC starting current (LRA)
Condenser fan --- AC power input (1)
Condenser fan --- AC max. power input
Condenser fan --- AC operative current (OA) (1)
Condenser fan --- AC max. current (FLA)
Condenser fan --- AC start---up current
Evaporator fan --- DC power input (1)
Evaporator fan --- DC operative current (OA) (1)
Evaporator fan --- DC max. current (FLA) (2)
Evaporator fan --- DC start---up current
Evaporator air flow
Freecooling air flow
Condenser max. air flow
Outdoor Sound Pressure Level (3)
Indoor Sound Pressure Level (3)
Max. ambient temperature (4)
kW
kW
kW
A
A
A
kW
kW
A
A
A
kW
A
A
A
m3/h
m3/h
m3/h
dB(A)
dB(A)
_C
6.1
5.4
1.75
8.1
11.4
47.0
0.11
0.24
0.8
1.4
1.6
0.14
3.0
6.0
0.1
1510
1400
2970
48.5
55
52
8.3
8.3
2.26
4.0
5.1
32.0
0.14
0.24
0.8
1.4
1.6
0.38
7.9
16.8
0.1
2670
2230
2970
48.5
60
49.5
10.5
10.1
3.08
5.5
7.0
46.0
0.22
0.48
1.5
2.8
3.3
0.38
7.9
16.8
0.1
2670
2230
6300
52.5
60
50.5
13.5
13.2
3.80
6.7
10.0
50.0
0.23
0.48
1.5
2.8
3.3
0.82
16.8
16.8
0.1
3950
3600
5675
53.5
62
49
14.7
13.6
4.76
8.7
10.2
63.0
0.28
0.48
1.7
2.8
3.3
0.82
16.8
16.8
0.1
3950
3600
5675
55.0
62
49
REFRIGERATION CIRCUITS
Compressor --- type / quantity
Refrigerant
Expansion device
Evaporator coil --- tubes / fins material
Condenser coil --- tubes / fins material
---
---
---
---
---
Scroll / 1
R407C
Thermostatic expansion valve
Copper / Aluminium
Copper / Aluminium
AIR FILTRATION
Main air filter --- quantity / type
Efficiency (CEN---EU)
---
---
1 / Pleated
G3
Filters dimension mm 740/230/48 946 / 300 / 60
EVAPORATOR FAN
Quantity / Type / Poles --- 2 / Plug / ---
Driven --- Direct
CONDENSER FAN
Quantity / Type / Poles --- 1 / Axial / 6 2 / Axial / 6
Driven / Motor protection --- Direct / IP54
Control system --- Variable speed
ELECTRIC HEATING
Type / Steps --- Tube / 1 Wires / 1
Heating capacity kW 3.0 6.0
Heating --- max. current A 13.1 8.7
CABINET
Frame --- Galvanised steel
Painting --- Polyester --- RAL7035
OVERALL DIMENSIONS
Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 920 / 1190 / 390
Width / Height / Depth SE_W indoor unit) mm 800/310/1050 1100 / 395 / 1395
Weight (HPSC outdoor unit) kg 80 82 97 103 111
Weight (SE_W indoor unit) kg 62 122 132
Notes:
(1) – Indoor reference conditions: 27˚C / 47% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply.
(2) – Values referred to nominal speed (factory set).
(3) --- Measured with outdoor temperature of 35˚C, at 2 m from the unit, in free field conditions.
(4) --- Maximum outdoor temperature referred to 27˚C / 47% R.H. air intake.
(*) --- HPSW 13 is composed by SE 13W + HPSC 12.
8DimensionalDrawings
8--1LiebertHPS---PD---272965---20.11.2009
Fig.4---EvaporatingunitHPSE06(versionwithfreecooling)
Condensatedrain
228150150150125
13,5 833 13,5
803
251,5300251,5
310
155 155
28.528.5803
310
FRONTVIEW(CIRCULARDUCTSVERSION)
TOPVIEW
LEFTSIDEVIEW
RIGHTSIDEVIEW
N.8slots9x12---
unitfixing
N.2collars
ø200H=35mm
Refrigerant
connection
Electrical
connection
803
70994
14.5
120,5562120,5
5919259
310
80328,528,5
FRONTVIEW(RECTANGULARDUCTVERSION)
Refrigerant
connection
Collar
190x560H=35mm
860
DimensionalDrawings
8--2LiebertHPS---PD---272965---20.11.2009
Fig.5---EvaporatingunitHPSE08--10--12--14(versionwithfreecooling)
Condensatedrain
226,5150150150
13,5 933 13,5
903
276,5350276,5
375
187,5
28.528.5903
375
TOPVIEW
LEFTSIDEVIEW
RIGHTSIDEVIEW
N.8slots9x12---
unitfixing
N.2collars
ø250H=35mm
Refrigerant
connection
Electrical
connection
903
81588
14.5
150,7601,6150,7
61,7251,661,7
375
90328,528,5
Refrigerant
connection
Collar
250x600H=35mm
960
187,5
226,5
FRONTVIEW(RECTANGULARDUCTVERSION)FRONTVIEW(CIRCULARDUCTSVERSION)
DimensionalDrawings
8--3LiebertHPS---PD---272965---20.11.2009
Fig.6---EvaporatingunitHPSE06--08--10(versionwithoutfreecooling)
28,580328,5
310
228150150150125
13,5 833 13,5
803
803
FRONTVIEW
TOPVIEWBOTTOMVIEW
310
803
860
LEFTSIDEVIEW
RIGHTSIDEVIEW
Condensatedrain
70994
14.5
Electrical
connection
N.8slots9x12---
unitfixing
Refrigerant
connection
DimensionalDrawings
8--4LiebertHPS---PD---272965---20.11.2009
Fig.7---EvaporatingunitHPSE12--14(versionwithoutfreecooling)
28,590328,5
375
226.5150150150226.5
13,5 933 13,5
903
903
FRONTVIEW
TOPVIEWBOTTOMVIEW
375
903
960
LEFTSIDEVIEW
RIGHTSIDEVIEW
Condensatedrain
80994
14.5
Electrical
connection
N.8slots9x12---
unitfixing
Refrigerant
connection
Dimensional Drawings
Liebert HPS---PD---272965---20.11.2009 8 -- 5
Fig. 8 --- Evaporating unit SE 06W (version with freecooling)
Condensate drain Condensate drain
N.6 HOLES 4 8
250800
3506035040
310
Circular ducts version
310
185125
N.2 COLLARS 4 200 HEIGHT 35 mm COLLAR 190 X 560 HEIGHT 35 mm
310
9019030
Rectangular duct version
83412 12
800 2929
1050
300 280220 560 15090
BOTTOM VIEW BOTTOM VIEW
REAR VIEW SIDE VIEW
TOP VIEW
Refrigerant outlet
Refrigerant inlet
Refrigerant outlet
Refrigerant inlet
Electrical connections
Dimensional Drawings
Liebert HPS---PD---272965---20.11.2009 8 -- 6
Fig. 9 --- Evaporating unit SE 06W (version without freecooling)
800
80029 29
83412 12
N.6 HOLES ø8
800
3506035040310
BOTTOM VIEW
REAR VIEW SIDE VIEW
TOP VIEW
Condensate drain
Refrigerant outlet
Refrigerant inlet
Electrical connections
Dimensional Drawings
Liebert HPS---PD---272965---20.11.2009 8 -- 7
Fig. 10 --- Evaporating unit SE 08--10--13--14W (version with freecooling)
Condensate drainCondensate drain
Refrigerant inlet Refrigerant inlet
2951100
3209032032050
395
395
220175220175
9550
N.2 COLLARS 4 250 HEIGHT 35 mm
N.8 HOLES 4 8
310 350 395
250
185 600 270
1395
30 1055 30
395
COLLAR 250 X 600 HEIGHT 35 mm
Circular ducts version Rectangular duct version
BOTTOM VIEW
REAR VIEW SIDE VIEW
TOP VIEW
BOTTOM VIEW
Electrical connections
Refrigerant outlet Refrigerant outlet
Dimensional Drawings
Liebert HPS---PD---272965---20.11.2009 8 -- 8
Fig. 11 --- Evaporating unit SE 08--10--13--14W (version without freecooling)
1100
BOTTOM VIEW
SIDE VIEW
TOP VIEW
Refrigerant inlet
Condensate drain
Refrigerant outlet
N.8 HOLES 4 8
Electrical connections
400
1052 3434
1100
3209032050320
1086 1717
400
REAR VIEW
DimensionalDrawings
8--9LiebertHPS---PD---272965---20.11.2009
Fig.12---CondensingunitHPSC06--08
A
132656132
390
354805 35
390
338
18 18
920
840
A
REARVIEWSIDEVIEW
FRONTVIEW
Refrigerant
outlet
Refrigerant
inlet
Refrigerant
outlet
Refrigerant
inlet
Electrical
connections
A---ASec.
DimensionalDrawings
8--10LiebertHPS---PD---272965---20.11.2009
Fig.13---CondensingunitHPSC10--12--14
1190
920390
338
2727
1155 35
656
390
35418 18
132132
A
A
REARVIEWSIDEVIEW
FRONTVIEW
A---ASec.
Refrigerant
outlet
Refrigerant
inlet
Refrigerant
outlet
Refrigerant
inlet
Electrical
connections
9 Installation
9 -- 1Liebert HPS---PD---272965---20.11.2009
Fig. 14 --- HPSE 06--08--10--12--14 evaporating unit ceiling installation (version without freecooling)
min.200
min. 300
803 (HPSE 06--08--10)
Service area
for electical
board
903 (HPSE 12--14)
310(HPSE06--08--10)
375(HPSE12--14)
Ceiling fixing points
Installation
9 -- 2Liebert HPS---PD---272965---20.11.2009
Fig. 15 --- HPSE 06--08--10--12--14 evaporating unit installation (version with freecooling)
HPSE A B C
06 min. 300 803 310
08---10---12---14 min. 320 903 375
ITEM DESCRIPTION
1 Electrical box accessibility
2 Support for filter
3 Air filter
4 Freecooling filter accessibility
5 Electrical box
1
2
3
4
3
3
5
min.200
min. 300
Service area
for electical
board
Servicearea
forFreecooling
filter
A
B
C
Installation
9 -- 3Liebert HPS---PD---272965---20.11.2009
Fig. 16 --- HPSE 06--08--10--12--14 evaporating unit ceiling installation (version with freecooling)
231
4
5
5
867
11
910
ITEM DESCRIPTION
COD.
HPSE 06
COD.
HPSE 08---10---12---14
1 Wall plate for circular duct 13503801 13536101
2 2 flexible ducts with fixing clamps, L = 0.5 m 270190 (ø 202mm) 270191 (ø 254mm)
3 Fixing clamps --- ---
4 Wall plate for rectangular duct 13501801 13536001
5 Circular / rectangular version --- ---
6 Wall hole 400 x 200mm 600 x 400mm
7 Overpressure damper 134948 134992
8 Grille for overpressure damper 270206 117832
9 Aluminium grille with metallic prefilter 270202 270219
10 Metallic prefilter (included in item 9) --- ---
11 Wall hole 550 x 210mm 590 x 230mm
Installation
9 -- 4Liebert HPS---PD---272965---20.11.2009
Fig. 17 --- SE 06--08--10--13--14W service area
CB D
A
B C DA
200 300 300 0
200 100 0 0
VERSION WITH FREECOOLING
VERSION WITHOUT FREECOOLING
E
700
700
E
B C
Fig. 18 --- SE 06--08--10--13--14W evaporating unit wall installation
1050(SE06W)
1550(SE06W)
min.500
1395(SE08---10---13---14W)
1895(SE08---10---13---14W)
AIRRETURN
AIR CONDITIONED
OUTSIDEAIR
800(SE06W)min.200
1000(SE06W)
1100(SE08---10---13---14W)
1300(SE08---10---13---14W)
AIR CONDITIONED
AIRRETURN
With freecooling option
Without freecooling option
Installation
9 -- 5Liebert HPS---PD---272965---20.11.2009
Fig. 19 --- SE 06--08--10--13--14W evaporating unit wall installation (version with freecooling)
1
2
9
8
10
7
6
4
3
5
11
10
8
9
ITEM DESCRIPTION
CODE
SE
06W
SE
08---10---13---14W
1 SE_W with FC option (optional rectangular hole) --- ---
2 SE_W with FC option (standard circular hole) --- ---
3 Overpressure damper 134948 134992
4 Grille for overpressure damper 270206 117832
5 Hole in the wall 400 x 200 mm 600 x 400 mm
6 2 FC flexible ducts L=0.5 m, with fixing clamps 270190 (∅ 202) 270191 (∅ 254)
7 Wall plate for FC circular duct 13503801 13536101
8 Aluminium grille with metallic prefilter 270202 270219
9 Metallic prefilter (included in (8) --- ---
10 Hole in the wall 550 x 210 mm 590 x 230 mm
11 Wall plate for FC rectangular duct 13501801 13536001
Installation
9 -- 6Liebert HPS---PD---272965---20.11.2009
Fig. 20 --- HPSC 06--08--10--12--14 condensing unit installation components
1
2
3
4
1
2
3
5
HPSC 06---08
HPSC 10---12---14
ITEM DESCRIPTION
1 Nut
2 Serrated lock washer
3 Washer
4 Anti---vibrating mount
5 Bracket
Installation
9 -- 7Liebert HPS---PD---272965---20.11.2009
Fig. 21 --- HPSC 06--08--10--12--14 service and working area
1
3
4
5
2
If H1 < 0.5 x H2 ⇒ L min. = 500 mm. . . . . . . . .
If 0.5 x H2 ≤ H1 ≤ H2 ⇒ L min. = 800 mm. . .
If H1 > H2 ⇒ Not allowable configuration. . . . . . . . . . . . . .
5
WALL IN FRONT
OF UNITS
WALL IN FRONT
OF UNITS
WALL BEHIND
UNITS
WALL BEHIND
UNITS
MULTI---ROWS
INSTALLATION
Installation
9 -- 8Liebert HPS---PD---272965---20.11.2009
Fig. 22 --- Liebert HPS (HPSE + HPSCxx0/A) suggested refrigerant connections
HPSE
(Internal Unit)
Gas pipeline
(Sloping 1%)
Liquid/gas pipeline
10 m max. horizontal equivalent length
Gas pipeline
(Sloping 1%)
Gas pipeline
(Sloping 1%)
HPSE
(Internal Unit)
HPSE
(Internal Unit)
7 m max. horizontal equivalent length
A
5mmax.vertical
distancebetween
twosyphons
3mmax.
verticaldistance
Syphons (obligatory)
NOTE:
Max. equivalent length for
refrigerant line A + B = 10 m
HPSC
(External Unit)
Gas pipeline
(Sloping 1%)
HPSC
(External Unit)
HPSC
(External Unit)
Gas pipeline
(Sloping 1%)
B
Liquid/gas pipeline
Liquid/gas pipeline
Installation
9 -- 9Liebert HPS---PD---272965---20.11.2009
Fig. 23 --- Liebert HPS (HPSE + HPSCxxL, Long piping) suggested refrigerant connections
5mmax.vertical
distancebetween
twosyphons
5mmax.vertical
distancebetween
twosyphons
HPSE
(Internal Unit)
Gas pipeline
(Sloping 1%)
50 m max. horizontal equivalent length
Gas pipeline
(Sloping 1%)
Gas pipeline
(Sloping 1%)
Gas pipeline
(Sloping 1%)
Gas pipeline
(Sloping 1%)
HPSE
(Internal Unit)
HPSE
(Internal Unit)
30 m max. horizontal equivalent length
30 m max. horizontal equivalent length
20mmax.
verticaldistance
20mmax.verticaldistance
Syphons (obligatory)
HPSC
(External Unit)
HPSC
(External Unit)
HPSC
(External Unit)
Liquid/gas pipeline
Liquid/gas pipeline
Liquid/gas pipeline
Installation
9 -- 10Liebert HPS---PD---272965---20.11.2009
Fig. 24 --- Liebert HPSW (SE_W + HPSCxxA) suggested refrigerant connections
5mmax.
vertical
distance
between
twosyphons
Gas pipeline
(Sloping 1%)
NOTE:
Max. equivalent length for
refrigerant line A + B = 10 m
Gas pipeline
(Sloping 1%)
10 m max. horizontal equivalent length
Gas pipeline
(Sloping 1%)
SE_W
(Internal Unit)
7 m max. horizontal equivalent length
A
Syphons
(obligatory)
HPSC
(External Unit)
Gas pipeline
(Sloping 1%)
HPSC
(External Unit)
Gas pipeline
(Sloping 1%)
SE_W
(Internal Unit)
B
SE_W
(Internal Unit)
3mmax.
verticaldistance
HPSC
(External Unit)
Liquid/gas pipeline
Liquid/gas pipeline
Liquid/gas pipeline
Installation
9 -- 11Liebert HPS---PD---272965---20.11.2009
Fig. 25 --- Liebert HPSW (SE_W + HPSCxxL, Long piping) suggested refrigerant connections
Gas pipeline
(Sloping 1%)
50 m max. horizontal equivalent length
Gas pipeline
(Sloping 1%)
Gas pipeline
(Sloping 1%)
SE_W
(Internal Unit)
30 m max. horizontal equivalent length
Syphons
(obligatory)
HPSC
(External Unit)
Gas pipeline
(Sloping 1%)
HPSC
(External Unit)
Gas pipeline
(Sloping 1%)
SE_W
(Internal Unit)
5mmax.
verticaldistance
between
twosyphons
5mmax.
vertical
distance
between
twosyphons
SE_W
(Internal Unit)
20mmax.
verticaldistance
HPSC
(External Unit)
20mmax.
verticaldistance
30 m max. horizontal equivalent length
Liquid/gas pipeline
Liquid/gas pipeline
Liquid/gas pipeline
PrintedinItalybyLiebertHIROSSS.pA.
IssuedbyT.D.Service
Since the Liebert HIROSS Company has a policy of continuous
product improvement, it reserves the right to change design and
specifications without previous notice.
Il Fabbricante dichiara che questo prodotto è conforme alle direttive Europee:
The Manufacturer hereby declares that this product conforms to the European Union directives:
Der Hersteller erklärt hiermit, dass dieses Produkt den Anforderungen der Europäischen Richtlinien gerecht wird:
Le Fabricant déclare que ce produit est conforme aux directives Européennes:
El Fabricante declara que este producto es conforme a las directivas Europeas:
O Fabricante declara que este produto está em conformidade com as directivas Europeias:
Tillverkare försäkrar härmed att denna produkt överensstämmer med Europeiska Uniones direktiv:
De Fabrikant verklaart dat dit produkt conform de Europese richtlijnen is:
Vaimistaja vakuuttaa täten, että tämä tuote täyättää seuraavien EU---direktiivien vaatimukset:
Produsent erklærer herved at dette produktet er i samsvar med EU---direktiver:
Fabrikant erklærer herved, at dette produkt opfylder kravene i EU direktiverne:
Ο Κατασ◶ευαστ δhλ νει τι τo πα◽ ν π◽oΪ ν ε ναι ◶ατασ◶ευασ νo α φwνα ε τι oδhγ ε τh Ε.Ε.:
2006/42/EC; 2004/108/EC; 2006/95/EC; 97/23/EC
While every precaution has been taken to ensure the accuracy
and completeness of this literature, Liebert Corporation assumes no
responsibility and accepts no liability for damages resulting from use of
this information or for any errors or omissions.
©2008 Liebert Corporation
All rights reserved throughout the world. Specifications subject to change
without notice.
Liebert and the Liebert logo are registered trademarks of Liebert
Corporation. All names referred to are trademarks
or registered trademarks of their respective owners.
Emerson Network Power, a business of Emerson (NYSE:EMR), is
the global leader in enabling Business-Critical Continuity™ from
grid to chip for telecommunication networks, data centers, health
care and industrial facilities. Emerson Network Power provides
innovative solutions and expertise in areas including AC and DC
power and precision cooling systems, embedded computing and
power, integrated racks and enclosures, power switching and
controls, monitoring, and connectivity. All solutions are supported
globally by local Emerson Network Power service technicians.
Liebert power, precision cooling and monitoring products and
services from Emerson Network Power improve the utilization
and management of data center and network technologies by
increasing IT system availability, flexibility and efficiency. For more
information, visit www.liebert.com, www.emersonnetworkpower.
com or www.eu.emersonnetworkpower.com
Locations
Emerson Network Power - Headquarters EMEA
Via Leonardo Da Vinci 16/18
Zona Industriale Tognana
35028 Piove di Sacco (PD) Italy
Tel: +39 049 9719 111
Fax: +39 049 5841 257
marketing.emea@emersonnetworkpower.com
Emerson Network Power - Service EMEA
Via Leonardo Da Vinci 16/18
Zona Industriale Tognana
35028 Piove di Sacco (PD) Italy
Tel: +39 049 9719 111
Fax: +39 049 9719045
service.emea@emersonnetworkpower.com
United States
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229
Tel: +1 614 8880246
Asia
7/F, Dah Sing Financial Centre
108 Gloucester Road,Wanchai
Hong Kong
Tel: +852 2572220
Fax: +852 28029250
Ensuring The High Availability
Of Mission-Critical Data And Applications.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Control
Precision Cooling
Rack & Integrated Cabinets
Services
Surge Protection
Emerson Network Power
The global leader in Business-Critical Continuity™.
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of EmersonElectric Co. ©2008 Emerson Electric Co.

More Related Content

Similar to Product manual hps

Lcp hybrid –_effi_cient_performance_with_heat_pipe_technology
Lcp hybrid –_effi_cient_performance_with_heat_pipe_technologyLcp hybrid –_effi_cient_performance_with_heat_pipe_technology
Lcp hybrid –_effi_cient_performance_with_heat_pipe_technologyEeu SC
 
H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...
H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...
H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...UniqueIndoorComfortLibertyville
 
Remko WKF inverter heat pump/ Bomba de calor inverter Remko WKF
Remko WKF inverter heat pump/ Bomba de calor inverter Remko WKFRemko WKF inverter heat pump/ Bomba de calor inverter Remko WKF
Remko WKF inverter heat pump/ Bomba de calor inverter Remko WKFDynamic444
 
P-Series Commercial Ductless and Ducted Cooling Systems Catalog Available fro...
P-Series Commercial Ductless and Ducted Cooling Systems Catalog Available fro...P-Series Commercial Ductless and Ducted Cooling Systems Catalog Available fro...
P-Series Commercial Ductless and Ducted Cooling Systems Catalog Available fro...UniqueIndoorComfortLibertyville
 
Innovations - Toshiba 17.02.14
Innovations - Toshiba 17.02.14Innovations - Toshiba 17.02.14
Innovations - Toshiba 17.02.14Overbury
 
PRESENTATION AIRWELL VRF 2014 GB
PRESENTATION  AIRWELL VRF 2014 GBPRESENTATION  AIRWELL VRF 2014 GB
PRESENTATION AIRWELL VRF 2014 GBArjang Ahmadi
 
Stulz mission energy
Stulz mission energyStulz mission energy
Stulz mission energyNick Turunov
 
Sb in rack-ver.1.0_en
Sb in rack-ver.1.0_enSb in rack-ver.1.0_en
Sb in rack-ver.1.0_enYury Naumov
 
Rittal top therm_chiller
Rittal top therm_chillerRittal top therm_chiller
Rittal top therm_chillerEeu SC
 
Mitsubishi 2011 price
Mitsubishi 2011 priceMitsubishi 2011 price
Mitsubishi 2011 pricedokundot
 
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161 Rittal - İklimlendirme ve Soğutma Ürünleri 144 161
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161 erdinc klima
 
Heatstar Technical Advice paper - 'New 2022 building regulations'
Heatstar Technical Advice paper - 'New 2022 building regulations'Heatstar Technical Advice paper - 'New 2022 building regulations'
Heatstar Technical Advice paper - 'New 2022 building regulations'Heatstar
 
Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)Beeteco
 

Similar to Product manual hps (20)

Lcp hybrid –_effi_cient_performance_with_heat_pipe_technology
Lcp hybrid –_effi_cient_performance_with_heat_pipe_technologyLcp hybrid –_effi_cient_performance_with_heat_pipe_technology
Lcp hybrid –_effi_cient_performance_with_heat_pipe_technology
 
H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...
H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...
H2i Residential Cooling and Heating System Carried By Unique Indoor Comfort L...
 
Remko WKF inverter heat pump/ Bomba de calor inverter Remko WKF
Remko WKF inverter heat pump/ Bomba de calor inverter Remko WKFRemko WKF inverter heat pump/ Bomba de calor inverter Remko WKF
Remko WKF inverter heat pump/ Bomba de calor inverter Remko WKF
 
P-Series Commercial Ductless and Ducted Cooling Systems Catalog Available fro...
P-Series Commercial Ductless and Ducted Cooling Systems Catalog Available fro...P-Series Commercial Ductless and Ducted Cooling Systems Catalog Available fro...
P-Series Commercial Ductless and Ducted Cooling Systems Catalog Available fro...
 
Innovations - Toshiba 17.02.14
Innovations - Toshiba 17.02.14Innovations - Toshiba 17.02.14
Innovations - Toshiba 17.02.14
 
PRESENTATION AIRWELL VRF 2014 GB
PRESENTATION  AIRWELL VRF 2014 GBPRESENTATION  AIRWELL VRF 2014 GB
PRESENTATION AIRWELL VRF 2014 GB
 
Toshiba
ToshibaToshiba
Toshiba
 
Data Center Cooling Study on Liquid Cooling
Data Center Cooling Study on Liquid CoolingData Center Cooling Study on Liquid Cooling
Data Center Cooling Study on Liquid Cooling
 
Stulz mission energy
Stulz mission energyStulz mission energy
Stulz mission energy
 
Sb in rack-ver.1.0_en
Sb in rack-ver.1.0_enSb in rack-ver.1.0_en
Sb in rack-ver.1.0_en
 
Catalog_Compactfans_US_en.pdf
Catalog_Compactfans_US_en.pdfCatalog_Compactfans_US_en.pdf
Catalog_Compactfans_US_en.pdf
 
Rittal top therm_chiller
Rittal top therm_chillerRittal top therm_chiller
Rittal top therm_chiller
 
Mitsubishi 2011 price
Mitsubishi 2011 priceMitsubishi 2011 price
Mitsubishi 2011 price
 
R y un50_00
R y un50_00R y un50_00
R y un50_00
 
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161 Rittal - İklimlendirme ve Soğutma Ürünleri 144 161
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161
 
Heatstar Technical Advice paper - 'New 2022 building regulations'
Heatstar Technical Advice paper - 'New 2022 building regulations'Heatstar Technical Advice paper - 'New 2022 building regulations'
Heatstar Technical Advice paper - 'New 2022 building regulations'
 
Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)
 
Carrier Inverter Ducted_tcm175-49778 (1).pdf
Carrier Inverter Ducted_tcm175-49778 (1).pdfCarrier Inverter Ducted_tcm175-49778 (1).pdf
Carrier Inverter Ducted_tcm175-49778 (1).pdf
 
P y un50_00
P y un50_00P y un50_00
P y un50_00
 
Module (1.3) types of ac units-hvac-apex
Module (1.3) types of ac units-hvac-apexModule (1.3) types of ac units-hvac-apex
Module (1.3) types of ac units-hvac-apex
 

Recently uploaded

如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一
如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一
如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一mjyguplun
 
Digamma / CertiCon Company Presentation
Digamma / CertiCon Company  PresentationDigamma / CertiCon Company  Presentation
Digamma / CertiCon Company PresentationMihajloManjak
 
Not Sure About VW EGR Valve Health Look For These Symptoms
Not Sure About VW EGR Valve Health Look For These SymptomsNot Sure About VW EGR Valve Health Look For These Symptoms
Not Sure About VW EGR Valve Health Look For These SymptomsFifth Gear Automotive
 
꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂
꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂
꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂Hot Call Girls In Sector 58 (Noida)
 
John Deere 300 3029 4039 4045 6059 6068 Engine Operation and Service Manual
John Deere 300 3029 4039 4045 6059 6068 Engine Operation and Service ManualJohn Deere 300 3029 4039 4045 6059 6068 Engine Operation and Service Manual
John Deere 300 3029 4039 4045 6059 6068 Engine Operation and Service ManualExcavator
 
(8264348440) 🔝 Call Girls In Shaheen Bagh 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Shaheen Bagh 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Shaheen Bagh 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Shaheen Bagh 🔝 Delhi NCRsoniya singh
 
UNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGER
UNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGERUNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGER
UNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGERDineshKumar4165
 
Call Girls Vastrapur 7397865700 Ridhima Hire Me Full Night
Call Girls Vastrapur 7397865700 Ridhima Hire Me Full NightCall Girls Vastrapur 7397865700 Ridhima Hire Me Full Night
Call Girls Vastrapur 7397865700 Ridhima Hire Me Full Nightssuser7cb4ff
 
如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一
如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一
如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一fjjwgk
 
FULL ENJOY - 9953040155 Call Girls in Sector 61 | Noida
FULL ENJOY - 9953040155 Call Girls in Sector 61 | NoidaFULL ENJOY - 9953040155 Call Girls in Sector 61 | Noida
FULL ENJOY - 9953040155 Call Girls in Sector 61 | NoidaMalviyaNagarCallGirl
 
如何办理(UQ毕业证书)昆士兰大学毕业证毕业证成绩单原版一比一
如何办理(UQ毕业证书)昆士兰大学毕业证毕业证成绩单原版一比一如何办理(UQ毕业证书)昆士兰大学毕业证毕业证成绩单原版一比一
如何办理(UQ毕业证书)昆士兰大学毕业证毕业证成绩单原版一比一hnfusn
 
What Causes DPF Failure In VW Golf Cars & How Can They Be Prevented
What Causes DPF Failure In VW Golf Cars & How Can They Be PreventedWhat Causes DPF Failure In VW Golf Cars & How Can They Be Prevented
What Causes DPF Failure In VW Golf Cars & How Can They Be PreventedAutobahn Automotive Service
 
如何办理(Flinders毕业证)查理斯特大学毕业证毕业证成绩单原版一比一
如何办理(Flinders毕业证)查理斯特大学毕业证毕业证成绩单原版一比一如何办理(Flinders毕业证)查理斯特大学毕业证毕业证成绩单原版一比一
如何办理(Flinders毕业证)查理斯特大学毕业证毕业证成绩单原版一比一ypfy7p5ld
 
2024 WRC Hyundai World Rally Team’s i20 N Rally1 Hybrid
2024 WRC Hyundai World Rally Team’s i20 N Rally1 Hybrid2024 WRC Hyundai World Rally Team’s i20 N Rally1 Hybrid
2024 WRC Hyundai World Rally Team’s i20 N Rally1 HybridHyundai Motor Group
 
GREEN VEHICLES the kids picture show 2024
GREEN VEHICLES the kids picture show 2024GREEN VEHICLES the kids picture show 2024
GREEN VEHICLES the kids picture show 2024AHOhOops1
 
定制多伦多大学毕业证(UofT毕业证)成绩单(学位证)原版一比一
定制多伦多大学毕业证(UofT毕业证)成绩单(学位证)原版一比一定制多伦多大学毕业证(UofT毕业证)成绩单(学位证)原版一比一
定制多伦多大学毕业证(UofT毕业证)成绩单(学位证)原版一比一meq5nzfnk
 
定制昆士兰大学毕业证(本硕)UQ学位证书原版一比一
定制昆士兰大学毕业证(本硕)UQ学位证书原版一比一定制昆士兰大学毕业证(本硕)UQ学位证书原版一比一
定制昆士兰大学毕业证(本硕)UQ学位证书原版一比一fjjhfuubb
 
定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一
定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一
定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一fhhkjh
 

Recently uploaded (20)

sauth delhi call girls in Connaught Place🔝 9953056974 🔝 escort Service
sauth delhi call girls in  Connaught Place🔝 9953056974 🔝 escort Servicesauth delhi call girls in  Connaught Place🔝 9953056974 🔝 escort Service
sauth delhi call girls in Connaught Place🔝 9953056974 🔝 escort Service
 
如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一
如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一
如何办理爱尔兰都柏林大学毕业证(UCD毕业证) 成绩单原版一比一
 
Digamma / CertiCon Company Presentation
Digamma / CertiCon Company  PresentationDigamma / CertiCon Company  Presentation
Digamma / CertiCon Company Presentation
 
Not Sure About VW EGR Valve Health Look For These Symptoms
Not Sure About VW EGR Valve Health Look For These SymptomsNot Sure About VW EGR Valve Health Look For These Symptoms
Not Sure About VW EGR Valve Health Look For These Symptoms
 
꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂
꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂
꧁༒☬ 7042364481 (Call Girl) In Dwarka Delhi Escort Service In Delhi Ncr☬༒꧂
 
John Deere 300 3029 4039 4045 6059 6068 Engine Operation and Service Manual
John Deere 300 3029 4039 4045 6059 6068 Engine Operation and Service ManualJohn Deere 300 3029 4039 4045 6059 6068 Engine Operation and Service Manual
John Deere 300 3029 4039 4045 6059 6068 Engine Operation and Service Manual
 
(8264348440) 🔝 Call Girls In Shaheen Bagh 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Shaheen Bagh 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Shaheen Bagh 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Shaheen Bagh 🔝 Delhi NCR
 
UNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGER
UNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGERUNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGER
UNIT-II-ENGINE AUXILIARY SYSTEMS &TURBOCHARGER
 
Hot Sexy call girls in Pira Garhi🔝 9953056974 🔝 escort Service
Hot Sexy call girls in Pira Garhi🔝 9953056974 🔝 escort ServiceHot Sexy call girls in Pira Garhi🔝 9953056974 🔝 escort Service
Hot Sexy call girls in Pira Garhi🔝 9953056974 🔝 escort Service
 
Call Girls Vastrapur 7397865700 Ridhima Hire Me Full Night
Call Girls Vastrapur 7397865700 Ridhima Hire Me Full NightCall Girls Vastrapur 7397865700 Ridhima Hire Me Full Night
Call Girls Vastrapur 7397865700 Ridhima Hire Me Full Night
 
如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一
如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一
如何办理(UC毕业证书)堪培拉大学毕业证毕业证成绩单原版一比一
 
FULL ENJOY - 9953040155 Call Girls in Sector 61 | Noida
FULL ENJOY - 9953040155 Call Girls in Sector 61 | NoidaFULL ENJOY - 9953040155 Call Girls in Sector 61 | Noida
FULL ENJOY - 9953040155 Call Girls in Sector 61 | Noida
 
如何办理(UQ毕业证书)昆士兰大学毕业证毕业证成绩单原版一比一
如何办理(UQ毕业证书)昆士兰大学毕业证毕业证成绩单原版一比一如何办理(UQ毕业证书)昆士兰大学毕业证毕业证成绩单原版一比一
如何办理(UQ毕业证书)昆士兰大学毕业证毕业证成绩单原版一比一
 
What Causes DPF Failure In VW Golf Cars & How Can They Be Prevented
What Causes DPF Failure In VW Golf Cars & How Can They Be PreventedWhat Causes DPF Failure In VW Golf Cars & How Can They Be Prevented
What Causes DPF Failure In VW Golf Cars & How Can They Be Prevented
 
如何办理(Flinders毕业证)查理斯特大学毕业证毕业证成绩单原版一比一
如何办理(Flinders毕业证)查理斯特大学毕业证毕业证成绩单原版一比一如何办理(Flinders毕业证)查理斯特大学毕业证毕业证成绩单原版一比一
如何办理(Flinders毕业证)查理斯特大学毕业证毕业证成绩单原版一比一
 
2024 WRC Hyundai World Rally Team’s i20 N Rally1 Hybrid
2024 WRC Hyundai World Rally Team’s i20 N Rally1 Hybrid2024 WRC Hyundai World Rally Team’s i20 N Rally1 Hybrid
2024 WRC Hyundai World Rally Team’s i20 N Rally1 Hybrid
 
GREEN VEHICLES the kids picture show 2024
GREEN VEHICLES the kids picture show 2024GREEN VEHICLES the kids picture show 2024
GREEN VEHICLES the kids picture show 2024
 
定制多伦多大学毕业证(UofT毕业证)成绩单(学位证)原版一比一
定制多伦多大学毕业证(UofT毕业证)成绩单(学位证)原版一比一定制多伦多大学毕业证(UofT毕业证)成绩单(学位证)原版一比一
定制多伦多大学毕业证(UofT毕业证)成绩单(学位证)原版一比一
 
定制昆士兰大学毕业证(本硕)UQ学位证书原版一比一
定制昆士兰大学毕业证(本硕)UQ学位证书原版一比一定制昆士兰大学毕业证(本硕)UQ学位证书原版一比一
定制昆士兰大学毕业证(本硕)UQ学位证书原版一比一
 
定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一
定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一
定制(Plymouth文凭证书)普利茅斯大学毕业证毕业证成绩单学历认证原版一比一
 

Product manual hps

  • 1. LiebertHPS--PD--272965--20.11.2009 Liebert HPS High Performance Split Air Conditioner for Mobile Network Access Nodes Precision Cooling for Business--Critical Continuity PRODUCT DOCUMENTATION HPSE HPSC SE_W
  • 2. Liebert HPS Liebert HPS---PD---272965---20.11.2009 Introduction Liebert HPS is the high performance split air conditioner family designed to assure proper environmental conditions inside technological environments, especially BTS and Node B for Mobile Networks. It’s composed of the HPSE indoor ceiling mounted module coupled with the HPSC outdoor module. It’s efficient thanks to the effectiveness air distribution reached through the displacement cooling concept; it’s energy and space saving thanks to the high efficiency components and the compactness of the innovative free cooling version; it’s ex- tremely flexible thanks to the possibility of selecting among several versions: Liebert HPS can be configured depending on the main application drivers (noise level, allowed environmental conditions range etc.) and the desired option (free cooling, emergency free cooling, heating etc.). The Liebert HPS family is also available in the HPSW version, made of the SE_W indoor wall mounted moudule coupled with the HPSC outdoor module. HPSE ceiling mounted module coupled with HPSC outdoor unit: the innovative ceiling mounted installa- tion and efficiency of displacement coolingconceptcoupledwiththereli- ability and quietness of HPSC out- door unit. SE_W wall mounted module coupled with HPSC outdoor unit: the traditional wall mounted installation coupled with the reliability and quiet- ness of HPSC outdoor unit.
  • 3. Index of Contents 0 -- 0Liebert HPS---PD---272965---20.11.2009 Contents 1 Features and Benefits 2 Model Description and Selection 3 Mechanical Specifications 4 Control 5 Options 6 Test and Reference Norms 7 Technical Data 8 Dimensional Drawings 9 Installation The product conforms to European Union directives 2006/42/EC; 2004/108/EC; 2006/95/EC and 97/23/EC. Units are supplied complete with a test certificate and conformity declaration and control component list. Liebert HPS units are CE marked as they comply with the European directives concerning mechanical, electrical and electromagnetic safety. The Quality Management System of Emerson Network Power S.r.l. High Performance Air Conditioning has been approved by Lloyd's Register Quality Assurance to the quality management system standard ISO 9001:2008.
  • 4. 1 Features and Benefits 1 -- 1Liebert HPS---PD---272965---20.11.2009 Distribute the air in the best way The HPSE, ceiling mounted indoor unit is thought to send the cold air straightly down, close to the racks suction area and intakes the hot air out coming from the heat sources, into the cabinet sides (frontal and lateral). In this way the mixing effect between conditioner cold air and electronic equipment hot air is denied resulting in a double beneficial effect: the rack is fed by cold air where it is needed and the air conditioner treats only the hot air maximizing its efficiency. Proper temperature inside the racks, high efficiency of the cooling equipment , hot spot absence in the site: distributing the air in a smart way is very effective. Save energy and space The use of the optional freecooling gives the possibility to stop the compressor and use the ex- ternal fresh air to cool the site: the annual energy absorption, requested to cool the site, goes sensibly down. The 0---100% fine modulation allows to keep constantly the desired set point in- side the site. Noadding module is requested when using the HPSE ceiling mounted indoorunit: theinnovative rotary freecooling system keeps unchanged the requested space to install the unit. Use the additional freecooling module to have the wall mounted (SE_W) solution. Maximize site reliability Remote nodes need to exchange data continuously, always working at proper environmental conditions. Therefore the air conditioner reliability is not an option: it’s a must. The most modern design and components such as scroll compressor and plug---type fans, heat exchanger surfaces and airflows generously designed allow the unit to work 24h/day, 365 days. Maximize the unit reliability selecting the emergency cooling option: in case of main supply fault the air conditioner is supplied by alternative energy sources like 48 VDC batteries or independent AC generator. Start---up quickly and easily the site Liebert HPS is ceiling mounted (HPSE) or wall mounted (SE_W): 2 rows with screws have to be used to easily fix the unit to the site ceiling or wall. No internal wiring of the air conditioner is re- quested thanks to the availability of the fast plug electrical connectors (special on request). The auto test software checks automatically all the main components operations, speeding up the site start up procedure. Choose the cooling unit suitable to your application Liebert HPS assures optimal air distribution, efficiency, energy saving, reliability, compactness whatever is its configuration. More stringent requirements in terms of noise level emission and maximum external working temperature, can be satisfied selecting HPSC advanced version: 45 dB(A) at 3m f.f and 50˚C with internal conditions of 27˚C, 35% R.H. at 1.5m from site floor. Long piping installations are not anymore a limit: using the “L” condenser version, high perform- ances are assured also when distance between outdoor and indoor unit is prohibitive. Respect the environment: ODP, TEWI and . . . noise level Now days green refrigerants are a standard (low Ozone Depletion Potential)! More than this, the most effective way to respect the environment is to reduce the energy absorption with a high effi- ciency refrigerant cycle. Liebert HPS reach a high EER (Energy Efficiency Ratio) value thanks to the use of large surface heat exchangers; this effect is maximized by the U---Shape coil used in the evaporating side. The relevant Total Equivalent Warming Impact (TEWI) value is reduced. Finally the importance of a low noise level: a different way, not less important, torespect the envir- onment. S Optimalracksfeedings S Highcoolingefficiency S Minimizetheenergy consumptionwiththe mostcompactsolution S Reliablecomponents S Emergencyfree (cooling)system S Fastplugelectrical connectors S Automatictest start---upsoftware S HPSCAdvanced S Lownoiselevel S Extremeenvironmental conditions S Longpiping S Greenrefrigerants S Highefficiency refrigerationcycle S Lownoiselevel
  • 5. 2 Model Description and Selection 2 -- 1Liebert HPS---PD---272965---20.11.2009 3 654 10987 Cooling Capacity “kW” (Nominal Cooling Capacity) 1 2 Model Nomenclature / Digit Numbers _ _ _ _ _ _ _ H P S E 0 6 Split Evaporator Section (Indoor Unit) High Performance Unit CEILING MOUNTED INDOOR UNIT HPSE 06 --- 14 BASE UNIT EVAPORATOR SECTION Split air cooled indoor unit Digits 1, 2, 3, 4, 5, 6 D RAL7035 “bright grey” cabinet Digit 7 --- Emergency cooling (EFC) 0 = No emergency cooling 1 = Emergency cooling through 48Vdc fan (*) 2 = Kit for connection to external inverter (*) (*) Option possible only if digit 9 = 1, 2, 3, or 4. Digit 8 --- Main power supply and electric heating (*) 0 = 230V / 1Ph / 50Hz (no electric heating) --- HPS 06 400V / 3Ph / 50Hz (no electric heating) --- HPS 08---14 1 = 230V / 1Ph / 50Hz (with electric heating) --- HPS 06 400V / 3Ph / 50Hz (with electric heating) --- HPS 08---14 (*) Power supply must be the same as per digit 5 of HPSC unit. Digit 9 --- Fresh air freecooling (FC) 0 = No freecooling 1 = FC circular holes --- modulating damper 2 = FC rectangular holes --- modulating damper 3 = FC circular holes --- fast return damper 4 = FC rectangular holes --- fast return damper Digit 10 ---Microprocessor control 1 = Control (no display) Plug for display available on indoor unit 2 = Control + remote display Remote wallmount display 3 = Connectivity (*) control (no display) Available plugs: LAN, remote display and graphic display 4 = Connectivity (*) control + remote display Available plugs: LAN, remote display and graphic display 5 = Connectivity (*)control+ graphicdisplay and language SetL1 Available plugs: LAN, remote display and graphic display 6 = Connectivity (*)control+ graphicdisplay and language SetL2 Available plugs: LAN, remote display and graphic display (*) To create LAN choose the Connectivity control and select the optional LAN cable. Language set L1: GB, F, I, D, E, P, NL, S. Language set L2: GB, PL, CZ , H, RUS, TK. Digit 11 ---Air filter 0 = G3 1 = G4 2 = G3 (indoor air) + clogged filter pressure switch (indoor air) 3 = G4 (indoor air) + clogged filter pressure switch (indoor air) Digit 12 ---Packing 0 = Cardboard and pallet C = Cardboard and wooden crate S = Seaworthy Digit 13 ---Free 0 = Free option always Digit 14 ---Evaporator coil 0 = Standard aluminium evaporator fins 1 = Epoxy coated evaporator fins Digit 15 ---Free 0 = Free option always Digit 16 ---Free 0 = Free option always Digit 17 ---Special requirements 0 = None X = Special
  • 6. Model Description and Selection 2 -- 2Liebert HPS---PD---272965---20.11.2009 Model Nomenclature / Digit Numbers 4 109871 2 S E 0 6 W Cooling Capacity “kW” (Nominal Cooling Capacity) Wall Mounted Unit 3 5 WALL MOUNTED INDOOR UNIT Split Evaporator Section (Indoor Unit) 6 _ _ _ _ _ _ _ SE 06 --- 14W BASE UNIT EVAPORATOR SECTION Split air cooled indoor unit Digits 1, 2, 3, 4 D RAL7035 “bright grey” cabinet D Air flow sensor Digit 5 W =Wall mounted Digit 6 --- Free 0 = Free option always Digit 7 --- Emergency cooling (EFC) 0 = No emergency cooling A = Emergency cooling through 48Vdc fan (*) 2 = Kit for connection to external inverter (*) B = Emergency cooling through 24Vdc fan (*) (*) Option possible only if digit 9 = 1, 2, 3, or 4. Digit 8 --- Main power supply and electric heating (*) 0 = 230V / 1Ph / 50Hz (no electric heating) --- HPSW 06 400V / 3Ph / 50Hz (no electric heating) --- HPSW 08---14 1 = 230V / 1Ph / 50Hz (with electric heating) --- HPSW 06 400V / 3Ph / 50Hz (with electric heating) --- HPSW 08---14 (*) Power supply must be the same as per digit 5 of HPSC unit. Digit 9 --- Fresh air freecooling (FC) 0 = No freecooling 1 = FC circular holes --- modulating damper 2 = FC rectangular holes --- modulating damper 3 = FC circular holes --- spring return damper 4 = FC rectangular holes --- spring return damper Digit 10 ---Microprocessor control A = Control + remote display Remote wallmount display B = Control + remote display + connection cables for stand---by Remote wallmount display inclusive of connectors cable C = Control + graphic display and language Set L1 (*) D = Control + graphic display and language Set L2 (*) (*) Language set L1: GB, F, I, D, E, P, NL, S. Language set L2: GB, PL, CZ , H, RUS, TK. Digit 11 ---Air filter 0 = G3 1 = G4 2 = G3 + clogged filter pressure switch 3 = G4 + clogged filter pressure switch Digit 12 ---Packing 0 = Pallet + heavy cardboard C = Cardboard and wooden crate S = Seaworthy Digit 13 ---Refrigerant 1 = R407C Digit 14 ---Evaporator coil 0 = Standard aluminium evaporator fins 1 = Epoxy coated evaporator fins Digit 15 ---Free 0 = Free option always Digit 16 ---Free 0 = Free option always Digit 17 ---Special requirements 0 = None X = Special
  • 7. Model Description and Selection 2 -- 3Liebert HPS---PD---272965---20.11.2009 Model Nomenclature / Digit Numbers 64 109871 2 H P S C 0 6 Cooling Capacity “kW” (Nominal Cooling Capacity) Split Condenser Section (Outdoor Unit) High Performance Unit 3 5 OUTDOOR UNIT HPSC 06 --- 14 BASE UNIT CONDENSER SECTION Split air cooled outdoor unit Digits 1, 2, 3, 4, 5, 6 D Scroll compressor D R407C --- 230V / 1Ph / 50Hz (6kW) D R407C --- 400V / 3Ph / 50Hz (8---14kW) D RAL7035 ”bright grey” cabinet Digit 7 --- Configuration 0 = Base (no sight glass filter, ON---OFF fan speed control) A = Advanced D Sight glass filter, modulating fan speed control, lower noise, higher external temperature L = Long piping application Digit 8 --- Condenser coil 0 = Standard aluminium fins 1 = Epoxy coated condenser fins 2 = Standard aluminium fins with protection grilles 3 = Epoxy coated condenser fins with protection grilles Digit 9 --- Packing 0 = Pallet + heavy cardboard C = Cardboard and wooden crate S = Seaworthy Digit 10 ---Special requirements 0 = None X = Special
  • 8. 3 Mechanical Specifications 3 -- 1Liebert HPS---PD---272965---20.11.2009 Refrigerant circuit The compressor, located in the moto---condensing section, is hermetic, scroll type, complete with internal protection against overheating. It is housed in a compartment separated from the air flow, protected by an insulated panel, accessible from the front side for complete maintenance. A crankcase heater maintains a minimum refrigerant temperature to allow reliable start---up and operation even in very cold climate. Depending on the configuration a capillary or a thermostatic expansion valve, filter dryer and sight glass, low pressure and high pressure switches and two access valves complete the refrigerant circuit. Evaporating section The evaporator section consists of a coil with copper tubes and aluminium fins, with a large face area in or- der to increase the SHR (Sensible Heat Ratio) and op- timize the EER (Energy Efficiency Ratio). The U---shape coil in the ceiling mounted unit, in- creases the heat exchange efficiency. A galvanized steel condensate drain tray (10/10mm thick) is provided. Depending on unit version, evaporating fan(s), all dir- ect driven, can be axial (HPSE ceiling mounted, cool- ing only), centrifugal (SE_W only cooling) or centrifu- gal backward curved (HPSE ceiling or SE_W wall mounted, Freecooling and Emergency Freecooling). Fans are statically and dynamically balanced with self---lubricated bearings, equipped with an airflow sensor as standard to provide an alarm in case of low airflow. Condensing section A wide surface condensing coil is provided. It is de- signed in copper tubes with aluminium fins and sized to allow operations at least up to up to 45˚C outdoor air temperature. The ”Advanced” version extends the external high temperature limit to 50˚C in order to satisfy extreme environmental working conditions. The units are equipped with 6---pole axial fan. The electrical motor is directly coupled on the motor shaft, with internal thermal protection and IP54. The innovative design of the impeller allows the maximum efficiency with the minimum noise. In Liebert HPS standard, the condenser fan is activated togeth- er with the compressor; a simple and valid solution where the re- quired noise level is not extremely low (50 dB(A) at 2m f.f), where the temperate climate doesn’t required to work in extremely low environment conditions (10˚C), where using the freecooling you can save your energy and go down to ---30˚C. In the ”Advanced” Liebert HPS, the condensing fan speed is smoothly regulated by a modulating control; it is the ideal solu- tion if the freecooling is not allowed and the air conditioner is re- quired to work in mechanical mode down to ---30˚C; it’s a must where extremely low noise level is required. Keeping the Advan- ced performances, the long piping version extends the allowed distance between the evaporating and condensing unit (see Fig. 22, Fig. 23, Fig. 24 and Fig. 25). Filtering section The filter section is placed vertically, before the evaporating coil and provides filtration of the in- ternal ambient and the fresh air to obtain the required degree of air cleanliness in the room. The filter can be removed from the bottom of the unit (indoor side) simply opening the relevant panel and unlocking the support brackets. The standard filter class is G3, according to Eurovent EU4/5 standard. A metallic pre---filter, enclosed in the freecooling air intake grill (accessory), protect the fresh air filter. S Scrollcompressor S Crankcaseheater S Filterdryerandsight glass S Highefficiencyfans andheatexchangers S Upto45_Cexternal temperatureand 50dB(A) S HPSCadvanced: upto50_Cand 48.5dB(A) S HPSClongpiping: upto50mdistance betweenevaporating andcondensingunit S Ambient:G3 S Freshair:pre---filter HPSE (CEILING) SE_W (WALL) HPSC
  • 9. Mechanical Specifications 3 -- 2Liebert HPS---PD---272965---20.11.2009 Cabinet Liebert HPS frame consists of riveted steel panels, treated with powder coating colour as stand- ard (RAL7035). The evaporating unit can be placed ceiling mounted (HPSE) or wall mounted (SE_W). In the HPSE, air inlet is located in the 3 side panels and the air supply is done from the bottom section, through an integrated grille. In the SE_W, air inlet is located at unit frontal bottom side and air supply is from unit top. The motor---condensing unit (HPSC) is designed to be installed outdoor and resist to worst weather conditions. The thermo---acoustic insulation of the panels is 10 mm thick, mineral wool type, density 70 kg/- m3. The motor---condensing unit takes the external air from the rear and discharge it on the front sec- tion. A frontal metal safety grid prevents contact with the fan. The insulation of the panels is made by a self---extinguishing material, specified as class V1 in re- lation to its fire proof properties. Electrical panel The electrical panel of the indoor unit is housed in easily accessible panel: it includes the circuit breaker for the AC power line, the circuit breaker for the optional DC power line and the electronic board. An external main switch is available on the unit side as standard. Thanks to the fast plug connectors (special on request), no internal wiring is needed: AC power line, DC power line, power supply for the condenser, general warning and alarm, display connec- tion, optional LAN connection are available on the side of the evaporating unit. The electrical board is built in accordance with EN 60204---1 recommendations. A single phase transformer supplies with 24 VAC the electronic control and the secondary circuit with maximum safety; in Liebert HPS with optional 48 VDC emergency freecooling system, the control is directly fed by the 48 VDC supply source. Automatic restart is provided after a power failure. The outdoor HPSC condenser unit receives main power supply fromthe indoorunit, togetherwith the control signals collected in a dedicated weather---proof terminal block. Operational limits HPS HPS 06 06 Advanced Long piping 08 08 to 14 Advanced Long piping Power supply voltage 230Vac ±10% / 1Ph / 50Hz 400Vac ±10% / 3Ph / 50Hz Outdoor working conditions from 10 ˚C (mechanical mode) ---30 ˚C 10 ˚C (mechanical mode) ---30 ˚C ---30 ˚C (freecooling mode) ---30 ˚C (freecooling mode) to 47 ˚C 51 ˚C 45 ˚C 50 ˚C Indoor working conditions (*) from 24 ˚C, 30% R.H. and 24 ˚C, 80% R.H. to 35 ˚C, 40% R.H. 34 ˚C, 40% R.H. 30 ˚C, 40% R.H. Storage conditions ---40 ˚C, 5% R.H. 55 ˚C, 90% R.H. (*) Conditions referred to indoor unit (HPSE) air intake section. S Nointernalwiring withthefastplug connectors accessories S Evaporatingside: ceilingmounted S Condensingside: worstweather conditionsresistance
  • 10. Mechanical Specifications 3 -- 3Liebert HPS---PD---272965---20.11.2009 HPSW HPSW 06 08 10 13 14 Power supply voltage 230V ±10% / 1Ph / 50Hz 400V ±10% / 3Ph + N + PE / 50Hz Outdoor working conditions from ---30 ˚C to 52 ˚C 49.5 ˚C 50.5 ˚C 49 ˚C Indoor working conditions (*) from 22 ˚C, 30% R.H., 80% R.H. 20 ˚C, 30% R.H., 80% R.H. to 30 ˚C, 40% R.H. Storage conditions ---40 ˚C, 5% R.H. 55 ˚C, 90% R.H. (*) --- The min. indoor temperature is referred to 30% of indoor relative humidity and to the min. outdoo temperat- ure; for higher relative humidity and/or outdoor temperatures, the min. indoor temperature is higher than the table data. The max. indoor temperature is referred to outdoor temperature of 35˚C; for higher indoor relative humidities and/or outdoor temperatures, the max indoor temperature is lower than the table data.
  • 11. Mechanical Specifications 3 -- 4Liebert HPS---PD---272965---20.11.2009 Fig. 1 --- HPSE ceiling mounted --- Operating diagram (without freecooling) ITEM DESCRIPTION 1 Evaporating coil 2 Fan Fig. 2 --- HPSE ceiling mounted --- Operating diagram (with freecooling) ITEM DESCRIPTION 1 Fresh air filter 2 Evaporating coil 3 Fan 4 Fan nozzle 5 Freecooling damper TOP VIEW (WITHOUT PANEL) CROSS SECTION Return air Treated air Return air 1 2 Return air Return air Freecooling air TOP VIEW (WITHOUT PANEL) CROSS SECTION Treated air Freecooling air 12 3 45
  • 12. Mechanical Specifications 3 -- 5Liebert HPS---PD---272965---20.11.2009 Fig. 3 --- SE_W wall mounted --- Operating diagram 8 5 SIDE AIR RETURN AIR CONDITIONED OUTSIDE AIR SIDE AIR CONDITIONED AIR RETURN With freecooling option Without freecooling option 6 4 3 2 1 7 2 7 5 3 8 4 ITEM DESCRIPTION 1 Freecooling damper 2 Air filter 3 Evaporator coil 4 Evaporator unit fan 5 Air discharge duct 6 Damper motor 7 Air suction grille 8 Electrical panel evaporating unit
  • 13. 4 Control 4 -- 1Liebert HPS---PD---272965---20.11.2009 Main features The main board is housed in the electrical panel of the HPSE and can be connected to the remote display, to be installed in the container/room (connection cable is included in the remote display option). D The user interface (option) is the 3---digit back---lit display showing parameter values and relevant symbols/codes in a tree menu. It features navigation push buttons and status leds. D General warning and general alarm signals are available: both of them activate a visual indicator in the optional display. D Input for remote On---Off and volt---free contacts for simple remote monitoring of general warning and alarms are available. D The self ---test function automatically activates/deactivates the main components (evaporator fan, compressor, freecooling damper, heaters, alarms) without changing the pre---set parameters, to easily start---up and commission the unit. No skilled personnel are requested (*). D All settings are protected through a 3---Level password system (*). D Automatic restart is provided after a power failure. (*) The Remote display is required to activate the function. Technical data D Power supply: 24 Vac / 24 Vdc / 48 Vdc. . . . . . . . . . . . . . . . . . D E2prom: 64 Kbit. . . . . . . . . . . . . . . . . . . . . . . D Eprom/Flash memory: 2 or 4 Mbit. . . . . . . . . . . D RAM memory space: 256 Kbit. . . . . . . . . . . . D Analogue Input: 1 x Analogue 0---10V. . . . . . . . . . . . . . . . 2 x Analogue 0---5V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Digital Input: 3 x PTC input. . . . . . . . . . . . . . . . . . . 5 x Flexible Digital multi input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Analogue Output: 2 x Analogue 0---10V. . . . . . . . . . . . . . . D Digital output: 3 x relay high power output. . . . . . . . . . . . . . . . . . 2 x relay 24Vac/48Vdc output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 x relay low power output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 x open collector 12Vdc output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Time and date function buffered by LI---battery D Hirobus LAN connectors (optional): 3 RJ45 sockets (to and from LAN connected units, remote display) D Hironet connectors: 1 RJ9 socket for RS485 (direct connection to. . . . . . . . . . . . . proprietary supervision) D Hiromatic E display (optional) D SMM mobile phones communications via SMS (optional)
  • 14. 5 Options 5 -- 1Liebert HPS---PD---272965---20.11.2009 Emergency cooling The unit is optionally equipped with an emergency cooling system that allows to ventilate or to cool through external fresh air the site in case of main electrical supply fault. For this purpose the evaporating fan section, the control, and the free cooling damper are sup- plied in 48 VDC power supply (from rectifier in normal mode, from batteries in emergency mode). This option guarantees the air circulation inside the site and if the control recognizes the proper external temperature to run the freecooling mode, the damper will open to fresh the site and get the required set point. The emergency cooling system is also available in 230 VAC. The compressor and the condenser fan are supplied by standard AC power. Heating The heating option include electric heaters (1.5 kW on model 06, 3.0 kW on models 08---10, 4.5 kW on model 12 and 6.0 kW on model 14), located in the air discharge plenum, one stage and ON---OFF regulation. A safety thermostat, with manual reset, prevents from reaching dangerous temperatures. Freecooling The freecooling system consists of a damper controlled and moved from a AC servomotor (48VDC supplied in the emergency version). The system allows a 0---100% modulating freecooling in order to respect the desired set point. The exhaust air is discharged outdoor through an overpressure damper mounted on the wall and available as accessory. The control allows the unit torun in freecooling mode when the difference between the indoor and outdoor air temperature reaches the required value to get the nominal cooling capacity. In emergency situation, the freecooling is allowed at a lower difference between the indoor and outdoor air temperature, in order to use the external fresh air as much as possible. In the HPSE ceiling mounted version, the innovative rotary system allows the air conditioner to be equipped with the freecooling system without any adding module, maintaining the standard unit dimensions. Connectivity The possibility to create a LAN is available selecting the “Connectivity” control version and con- necting two or more units through the Hirobus cable (optional). Functions provided include stand---by (in case of failure or overload of the unit in operation, the second one starts automatic- ally), automatic rotation and cascade (sharing of the total load among several units). Special filtration Optional high---level filtration can be reached. A clogged filter system can be supplied to advise when the indoor air filter is dirty. Package Standard packing consists of a wooden pallet and cardboard box. Polythene foam protects the units’ painted surfaces. On request, a cardboard box with an additional wooden crate or wooden case for sea transport can be supplied. Corrosive environments protection The condenser coil and/or evaporator coils are available with aluminium fins coated by epoxy film, to protect from aggressive environmental conditions. Long piping installation Select the “L” condenser option to allow long piping installations between outdoor and indoor units: up to50 m of equivalent length with up to20 m of height level difference, being the condens- ing unit below or above the evaporating one, doesn’t matter. The “L” condenser version includes also all features provided within condenser “Advanced” ver- sion (”A”). S Uninterruptible ventilation S Freecoolingevenin emergencyconditions S ON---OFFcontrol S Safetythermostat S Compactsystem S 0---100% modulation S G4filter S Cloggedfilter S Cardboardbox S Woodencrate S LANmanagement S Epoxycoatedcoils S Up to 50m equivalent length
  • 15. 6 Test and Reference Norms 6 -- 1Liebert HPS---PD---272965---20.11.2009 Safety Liebert HPS units are designed, manufactured and tested according to the European Union dir- ectives: D 2006/42/EC; D 2004/108/EC; D 2006/95/EC; D 97/23/EC. Electrical Board Design and manufacturing is compliant with EN 60204---1. Electro---Magnetic compatibility (EMC) Liebert HPS complies with the following EMC standards: D EN 50081---1, Emission (“Generic emission standard, Part 1: Residential, commercial and light industry, Jan 1992”) D EN 50082---2, Immunity (“Generic immunity standard, Part 2: Industrial environment, Mar 1995”). Mark Each unit is supplied complete with individual test certificate and a declara- tion of conformity to the European Union directives. The units are marked “CE”. Quality The Quality Management System of Emerson Network Power S.r.l. High Performance Air Conditioning has been approved by Lloyd’s Re- gister Quality Assurance to the quality management system standard ISO 9001:2008.
  • 16. 7 Technical Data 7 -- 1Liebert HPS---PD---272965---20.11.2009 Tab. 1 --- HPSE + HPSC (No freecooling version) MODEL: HPS 06 08 Air supply --- Downflow Main power supply --- 230V±10%/1Ph/50Hz 400V±10%/3Ph+N+PE/50Hz PERFORMANCE Total cooling capacity (1) Sensible cooling capacity (1) Compressor --- AC power input (1) Compressor --- AC operative current (OA) (1) Compressor --- AC max current (FLA) Compressor --- AC starting current (LRA) Condenser fan --- AC power input (1) Condenser fan --- AC max. power input Condenser fan --- AC operative current (OA) (1) Condenser fan --- AC max. current (FLA) Condenser fan --- AC start---up current Evaporator fan --- AC power input (1) Evaporator fan --- AC operative current (OA) (1) Evaporator fan --- AC max. current (FLA) (2) Evaporator fan --- AC start---up current Evaporator air flow Condenser max. air flow Outdoor Sound Pressure Level (3) Indoor Sound Pressure Level (3) Max. ambient temperature (4) kW kW kW A A A kW kW A A A kW A A A m3/h m3/h dB(A) dB(A) _C 6.4 6.4 1.58 7.6 11.4 47.0 0.08 0.08 0.6 1.4 1.6 0.18 0.8 1.0 1.3 1510 2170 50 58 47 8.2 8.2 2.18 3.9 5.1 32.0 0.10 0.10 0.7 1.4 1.6 0.35 1.5 2.0 2.7 2440 1920 50 62.5 45 REFRIGERATION CIRCUITS Compressor --- type / quantity Refrigerant Expansion device Evaporator coil --- tubes / fins material Condenser coil --- tubes / fins material --- --- --- --- --- Scroll / 1 R407C Capillary Copper / Aluminium Copper / Aluminium AIR FILTRATION Main air filter --- quantity / type Efficiency (CEN---EU) --- --- 3 / Panel filters G3 Filters dimensiond (DX side) mm 597 / 267 / 10 EVAPORATOR FAN Quantity / Type / Poles --- 1 / Axial / 4 Driven / Motor protection --- Direct / IP44 Direct / IP54 CONDENSER FAN Quantity / Type / Poles --- 1 / Axial / 6 Driven / Motor protection --- Direct / IP54 Control system --- Single speed ELECTRIC HEATING Type / Steps --- Wires / 1 Heating capacity kW 1.5 3.0 Heating --- max. current A 6.5 CABINET Frame --- Galvanised steel Painting --- Polyester --- RAL7035 OVERALL DIMENSIONS Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 Width / Height / Depth (HPSE indoor unit) mm 800 / 310 / 800 Weight (HPSC outdoor unit) kg 80 82 Weight (HPSE indoor unit) kg 50 53 Notes: (1) – Indoor reference conditions: 30˚C / 35% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply. (2) – Values referred to nominal speed (factory set). (3) --- Measured with max. outdoor temperature at 2 m from the unit, in free field conditions. (4) --- Maximum outdoor temperature referred to 30˚C / 35% R.H. air intake.
  • 17. Technical Data 7 -- 2Liebert HPS---PD---272965---20.11.2009 Tab. 2 --- HPSE + HPSC (Freecooling and AC emergency freecooling versions) MODEL: HPS 06 08 Air supply --- Downflow Main power supply --- 230V±10% / 1Ph / 50Hz 400V±10%/3Ph+N+PE/50Hz Emergency power supply --- 230V±10% / 1Ph / 50Hz PERFORMANCE Total cooling capacity (1) Sensible cooling capacity (1) Compressor --- AC power input (1) Compressor --- AC operative current (OA) (1) Compressor --- AC max current (FLA) Compressor --- AC starting current (LRA) Condenser fan --- AC power input (1) Condenser fan --- AC max. power input Condenser fan --- AC operative current (OA) (1) Condenser fan --- AC max. current (FLA) Condenser fan --- AC start---up current Evaporator fan --- AC power input (1) Evaporator fan --- AC operative current (OA) (1) Evaporator fan --- AC max. current (FLA) (2) Evaporator fan --- AC start---up current Evaporator air flow Freecooling air flow Condenser max. air flow Outdoor Sound Pressure Level (3) Indoor Sound Pressure Level (3) Max. ambient temperature (4) kW kW kW A A A kW kW A A A kW A A A m3/h m3/h m3/h dB(A) dB(A) _C 5.9 5.9 1.57 7.3 11.4 47.0 0.08 0.08 0.6 1.4 1.6 0.14 0.6 0.6 1.2 1390 820 2170 50 59 48 8.3 8.3 2.18 3.9 5.1 32.0 0.10 0.10 0.7 1.4 1.6 0.39 2.8 2.4 5.3 2020 2040 1920 50 62.5 45 REFRIGERATION CIRCUITS Compressor --- type / quantity Refrigerant Expansion device Evaporator coil --- tubes / fins material Condenser coil --- tubes / fins material --- --- --- --- --- Scroll / 1 R407C Capillary Copper / Aluminium Copper / Aluminium AIR FILTRATION Main air filter --- quantity / type Efficiency (CEN---EU) --- --- 3 / Panel filters for DX side --- 1 / Plated panel filter for FC side G3 Filters dimensiond (DX side) mm 597 / 267 / 10 697 / 332 / 10 Filters dimensiond (FC side) mm 580 / 300 / 50 680 / 365 / 50 EVAPORATOR FAN Quantity / Type / Poles --- 1 / Plug / 4 Driven / Motor protection --- Direct / IP44 Direct / IP54 CONDENSER FAN Quantity / Type / Poles --- 1 / Axial / 6 Driven / Motor protection --- Direct / IP54 Control system --- Single speed ELECTRIC HEATING Type / Steps --- Wires / 1 Heating capacity kW 1.5 3.0 Heating --- max. current A 6.5 CABINET Frame --- Galvanised steel Painting --- Polyester --- RAL7035 OVERALL DIMENSIONS Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 Width / Height / Depth (HPSE indoor unit) mm 800 / 310 / 800 900 / 375 / 900 Weight (HPSC outdoor unit) kg 80 82 Weight (HPSE indoor unit) kg 55 63 Notes: (1) – Indoor reference conditions: 30˚C / 35% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply. (2) – Values referred to nominal speed (factory set). (3) --- Measured with max. outdoor temperature at 2 m from the unit, in free field conditions. (4) --- Maximum outdoor temperature referred to 30˚C / 35% R.H. air intake.
  • 18. Technical Data 7 -- 3Liebert HPS---PD---272965---20.11.2009 Tab. 3 --- HPSE + HPSC (Freecooling and DC emergency freecooling versions) MODEL: HPS 06 08 Air supply --- Downflow Main power supply --- 230V±10% / 1Ph / 50Hz 4000V±10%/3Ph+N+PE/5Hz Emergency power supply --- 48 VDC PERFORMANCE Total cooling capacity (1) Sensible cooling capacity (1) Compressor --- AC power input (1) Compressor --- AC operative current (OA) (1) Compressor --- AC max current (FLA) Compressor --- AC starting current (LRA) Condenser fan --- AC power input (1) Condenser fan --- AC max. power input Condenser fan --- AC operative current (OA) (1) Condenser fan --- AC max. current (FLA) Condenser fan --- AC start---up current Evaporator fan --- DC power input (1) Evaporator fan --- DC operative current (OA) (1) Evaporator fan --- DC max. current (FLA) (2) Evaporator fan --- DC start---up current Evaporator air flow Freecooling air flow Condenser max. air flow Outdoor Sound Pressure Level (3) Indoor Sound Pressure Level (3) Max. ambient temperature (4) kW kW kW A A A kW kW A A A kW A A A m3/h m3/h m3/h dB(A) dB(A) _C 5.9 5.9 1.57 7.3 11.4 47.0 0.08 0.08 0.6 1.4 1.6 0.10 2.6 2.6 0.1 1350 820 2170 50 57 48 8.2 8.2 2.17 3.9 5.1 32.0 0.10 0.10 0.7 1.4 1.6 0.28 5.8 9.6 0.1 1910 2040 1920 50 62 45 REFRIGERATION CIRCUITS Compressor --- type / quantity Refrigerant Expansion device Evaporator coil --- tubes / fins material Condenser coil --- tubes / fins material --- --- --- --- --- Scroll / 1 R407C Capillary Copper / Aluminium Copper / Aluminium AIR FILTRATION Main air filter --- quantity / type Efficiency (CEN---EU) --- --- 3 / Panel filters for DX side --- 1 / Plated panel filter for FC side G3 Filters dimensiond (DX side) mm 597 / 267 / 10 697 / 332 / 10 Filters dimensiond (FC side) mm 580 / 300 / 50 680 / 365 / 50 EVAPORATOR FAN Quantity / Type / Poles --- 1 / Plug / --- Driven / Motor protection --- Direct / IP42 Direct / IP20 CONDENSER FAN Quantity / Type / Poles --- 1 / Axial / 6 Driven / Motor protection --- Direct / IP54 Control system --- Single speed ELECTRIC HEATING Type / Steps --- Wires / 1 Heating capacity kW 1.5 3.0 Heating --- max. current A 6.5 CABINET Frame --- Galvanised steel Painting --- Polyester --- RAL7035 OVERALL DIMENSIONS Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 Width / Height / Depth (HPSE indoor unit) mm 800 / 310 / 800 900 / 375 / 900 Weight (HPSC outdoor unit) kg 80 82 Weight (HPSE indoor unit) kg 55 63 Notes: (1) – Indoor reference conditions: 30˚C / 35% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply. (2) – Values referred to nominal speed (factory set). (3) --- Measured with max. outdoor temperature at 2 m from the unit, in free field conditions. (4) --- Maximum outdoor temperature referred to 30˚C / 35% R.H. air intake.
  • 19. Technical Data 7 -- 4Liebert HPS---PD---272965---20.11.2009 Tab. 4 --- HPSE + HPSC Advanced/Long piping (No freecooling version) MODEL: HPS ADVANCED/LONG PIPING 06 08 10 12 14 Air supply --- Downflow Main power supply --- 230V±10% / 1Ph / 50Hz 400V±10% / 3Ph+N+PE / 50Hz PERFORMANCE Total cooling capacity (1) Sensible cooling capacity (1) Compressor --- AC power input (1) Compressor --- AC operative current (OA) (1) Compressor --- AC max current (FLA) Compressor --- AC starting current (LRA) Condenser fan --- AC power input (1) Condenser fan --- AC max. power input Condenser fan --- AC operative current (OA) (1) Condenser fan --- AC max. current (FLA) Condenser fan --- AC start---up current Evaporator fan --- AC power input (1) Evaporator fan --- AC operative current (OA) (1) Evaporator fan --- AC max. current (FLA) (2) Evaporator fan --- AC start---up current Evaporator air flow Condenser max. air flow Outdoor Sound Pressure Level (3) Indoor Sound Pressure Level (3) Max. ambient temperature (4) kW kW kW A A A kW kW A A A kW A A A m3/h m3/h dB(A) dB(A) _C 6.4 6.4 1.73 8.0 11.4 47.0 0.07 0.24 0.6 1.4 1.6 0.18 0.8 1.0 1.3 1510 2970 48.5 58 51 8.1 8.1 2.23 4.0 5.1 32.0 0.10 0.24 0.7 1.4 1.6 0.35 1.5 2.0 2.7 2440 2970 48.5 62.5 50 10.0 10.0 3.06 5.5 7.0 46.0 0.22 0.48 1.5 2.8 3.3 0.35 1.5 2.0 2.7 2440 6300 52.5 62.5 50 12.5 12.5 3.75 6.6 10.0 50.0 0.22 0.48 1.5 2.8 3.3 0.34 2.0 2.0 2.7 2770 5675 53.5 64 50 14.6 14.6 4.68 8.6 10.2 63.0 0.28 0.48 1.7 2.8 3.3 0.34 2.0 2.0 2.7 2750 5675 55.0 64 50 REFRIGERATION CIRCUITS Compressor --- type / quantity Refrigerant Expansion device Evaporator coil --- tubes / fins material Condenser coil --- tubes / fins material --- --- --- --- --- Scroll / 1 R407C Thermostatic expansion valve Copper / Aluminium Copper / Aluminium AIR FILTRATION Main air filter --- quantity / type Efficiency (CEN---EU) --- --- 3 / Panel filters G3 Filters dimensiond (DX side) mm 597 / 267 / 10 697 / 332 / 10 EVAPORATOR FAN Quantity / Type / Poles --- 1 / Axial / 4 Driven / Motor protection --- Direct / IP44 Direct / IP54 CONDENSER FAN Quantity / Type / Poles --- 1 / Axial / 6 2 / Axial / 6 Driven / Motor protection --- Direct / IP54 Control system --- Variable speed ELECTRIC HEATING Type / Steps --- Wires / 1 Heating capacity kW 1.5 3.0 3.0 4.5 6.0 Heating --- max. current A 6.5 13.0 CABINET Frame --- Galvanised steel Painting --- Polyester --- RAL7035 OVERALL DIMENSIONS Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 920 / 1190 / 390 Width / Height / Depth (HPSE indoor unit) mm 800 / 310 / 800 900 / 375 / 900 Weight (HPSC outdoor unit) kg 80 82 97 103 111 Weight (HPSE indoor unit) kg 50 53 58 Notes: (1) – Indoor reference conditions: 30˚C / 35% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply. (2) – Values referred to nominal speed (factory set). (3) --- Measured with outdoor temperature of 35˚C, at 2 m from the unit, in free field conditions. (4) --- Maximum outdoor temperature referred to 30˚C / 35% R.H. air intake.
  • 20. Technical Data 7 -- 5Liebert HPS---PD---272965---20.11.2009 Tab. 5 --- HPSE + HPSC Advanced/Long piping (Freecooling and AC emergency freecooling versions) MODEL: HPS ADVANCED/LONG PIPING 06 08 10 12 14 Air supply --- Downflow Main power supply --- 230V ±10% / 1Ph / 50Hz 400V±10% / 3Ph+N+PE / 50Hz Emergency power supply --- 230V±10% / 1Ph / 50Hz PERFORMANCE Total cooling capacity (1) Sensible cooling capacity (1) Compressor --- AC power input (1) Compressor --- AC operative current (OA) (1) Compressor --- AC max current (FLA) Compressor --- AC starting current (LRA) Condenser fan --- AC power input (1) Condenser fan --- AC max. power input Condenser fan --- AC operative current (OA) (1) Condenser fan --- AC max. current (FLA) Condenser fan --- AC start---up current Evaporator fan --- AC power input (1) Evaporator fan --- AC operative current (OA) (1) Evaporator fan --- AC max. current (FLA) (2) Evaporator fan --- AC start---up current Evaporator air flow Freecooling air flow Condenser max. air flow Outdoor Sound Pressure Level (3) Indoor Sound Pressure Level (3) Max. ambient temperature (4) kW kW kW A A A kW kW A A A kW A A A m3/h m3/h m3/h dB(A) dB(A) _C 5.9 5.9 1.74 8.1 11.4 47.0 0.07 0.24 0.6 1.4 1.6 0.14 0.6 0.7 1.2 1390 820 2970 48.5 59 52 8.3 8.3 2.22 4.0 5.1 32.0 0.10 0.24 0.7 1.4 1.6 0.39 2.8 2.4 5.3 2020 2040 2970 48.5 62.5 50 10.3 10.3 3.06 5.5 7.0 46.0 0.22 0.48 1.5 2.8 3.3 0.39 2.8 2.4 5.3 2020 2040 6300 52.5 62.5 50 12.0 12.0 3.75 6.6 10.0 50.0 0.22 0.48 1.5 2.8 3.3 0.45 2.9 2.4 5.3 2220 2040 5675 53.5 64.5 50 14.1 13.8 4.66 8.5 10.2 63.0 0.28 0.48 1.7 2.8 3.3 0.48 2.4 2.4 5.3 2410 2040 5675 55 66 50 REFRIGERATION CIRCUITS Compressor --- type / quantity Refrigerant Expansion device Evaporator coil --- tubes / fins material Condenser coil --- tubes / fins material --- --- --- --- --- Scroll / 1 R407C Thermostatic expansion valve Copper / Aluminium Copper / Aluminium AIR FILTRATION Main air filter --- quantity / type Efficiency (CEN---EU) --- --- 3 / Panel filters for DX side --- 1 / Plated panel filter for FC side G3 Filters dimensiond (DX side) mm 597/267/10 697 / 332 / 10 Filters dimensiond (FC side) mm 580/300/50 680 / 365 / 50 EVAPORATOR FAN Quantity / Type / Poles --- 1 / Plug / 4 Driven / Motor protection --- Direct / IP44 Direct / IP54 CONDENSER FAN Quantity / Type / Poles --- 1 / Axial / 6 2 / Axial / 6 Driven / Motor protection --- Direct / IP54 Control system --- Variable speed ELECTRIC HEATING Type / Steps --- Wires / 1 Heating capacity kW 1.5 3.0 3.0 4.5 6.0 Heating --- max. current A 6.5 13.0 CABINET Frame --- Galvanised steel Painting --- Polyester --- RAL7035 OVERALL DIMENSIONS Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 920 / 1190 / 390 Width / Height / Depth (HPSE indoor unit) mm 800/310/800 900 / 375 / 900 Weight (HPSC outdoor unit) kg 80 82 97 103 111 Weight (HPSE indoor unit) kg 55 63 Notes: (1) – Indoor reference conditions: 30˚C / 35% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply. (2) – Values referred to nominal speed (factory set). (3) --- Measured with outdoor temperature of 35˚C, at 2 m from the unit, in free field conditions. (4) --- Maximum outdoor temperature referred to 30˚C / 35% R.H. air intake.
  • 21. Technical Data 7 -- 6Liebert HPS---PD---272965---20.11.2009 Tab. 6 --- HPSE + HPSC Advanced/Long piping (Freecooling and DC emergency freecooling versions) MODEL: HPS ADVANCED/LONG PIPING 06 08 10 12 14 Air supply --- Downflow Main power supply --- 230V ±10% / 1Ph / 50Hz 400V±10% / 3Ph+N+PE / 50Hz Emergency power supply --- 48 VDC PERFORMANCE Total cooling capacity (1) Sensible cooling capacity (1) Compressor --- AC power input (1) Compressor --- AC operative current (OA) (1) Compressor --- AC max current (FLA) Compressor --- AC starting current (LRA) Condenser fan --- AC power input (1) Condenser fan --- AC max. power input Condenser fan --- AC operative current (OA) (1) Condenser fan --- AC max. current (FLA) Condenser fan --- AC start---up current Evaporator fan --- DC power input (1) Evaporator fan --- DC operative current (OA) (1) Evaporator fan --- DC max. current (FLA) (2) Evaporator fan --- DC start---up current Evaporator air flow Freecooling air flow Condenser max. air flow Outdoor Sound Pressure Level (3) Indoor Sound Pressure Level (3) Max. ambient temperature (4) kW kW kW A A A kW kW A A A kW A A A m3/h m3/h m3/h dB(A) dB(A) _C 5.9 5.9 1.74 8.1 11.4 47.0 0.07 0.24 0.6 1.4 1.6 0.10 2.6 2.6 0.1 1350 820 2970 48.5 57 52 8.2 8.2 2.23 4.0 5.1 32.0 0.10 0.24 0.7 1.4 1.6 0.28 5.8 9.6 0.1 1910 2040 2970 48.5 62 50 10.2 10.2 3.06 5.5 7.0 46.0 0.22 0.48 1.5 2.8 3.3 0.28 5.8 9.6 0.1 1910 2040 6300 52.5 62 50 12.0 12.0 3.75 6.6 10.0 50.0 0.22 0.48 1.5 2.8 3.3 0.39 8.1 9.6 0.1 2240 2040 5675 53.5 67 50 14.0 13.7 4.66 8.5 10.2 63.0 0.28 0.48 1.7 2.8 3.3 0.45 9.5 9.6 0.1 2380 2040 5675 55 68.5 50 REFRIGERATION CIRCUITS Compressor --- type / quantity Refrigerant Expansion device Evaporator coil --- tubes / fins material Condenser coil --- tubes / fins material --- --- --- --- --- Scroll / 1 R407C Thermostatic expansion valve Copper / Aluminium Copper / Aluminium AIR FILTRATION Main air filter --- quantity / type Efficiency (CEN---EU) --- --- 3 / Panel filters for DX side --- 1 / Plated panel filter for FC side G3 Filters dimensiond (DX side) mm 597/267/10 697 / 332 / 10 Filters dimensiond (FC side) mm 580/300/50 680 / 365 / 50 EVAPORATOR FAN Quantity / Type / Poles --- 1 / Plug / --- Driven / Motor protection --- Direct / IP42 Direct / IP20 CONDENSER FAN Quantity / Type / Poles --- 1 / Axial / 6 2 / Axial / 6 Driven / Motor protection --- Direct / IP54 Control system --- Variable speed ELECTRIC HEATING Type / Steps --- Wires / 1 Heating capacity kW 1.5 3.0 3.0 4.5 6.0 Heating --- max. current A 6.5 13.0 CABINET Frame --- Galvanised steel Painting --- Polyester --- RAL7035 OVERALL DIMENSIONS Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 920 / 1190 / 390 Width / Height / Depth (HPSE indoor unit) mm 800/310/800 900 / 375 / 900 Weight (HPSC outdoor unit) kg 80 82 97 103 111 Weight (HPSE indoor unit) kg 55 63 Notes: (1) – Indoor reference conditions: 30˚C / 35% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply. (2) – Values referred to nominal speed (factory set). (3) --- Measured with outdoor temperature of 35˚C, at 2 m from the unit, in free field conditions. (4) --- Maximum outdoor temperature referred to 30˚C / 35% R.H. air intake.
  • 22. Technical Data 7 -- 7Liebert HPS---PD---272965---20.11.2009 Tab. 7 --- SE_W + HPSC (No freecooling version) MODEL: HPSW 06 08 10 13 (*) 14 Air supply --- Upflow Main power supply --- 230V±10% / 1Ph / 50Hz 400V ±10% / 3Ph+N+PE / 50Hz PERFORMANCE Total cooling capacity (1) Sensible cooling capacity (1) Compressor --- AC power input (1) Compressor --- AC operative current (OA) (1) Compressor --- AC max current (FLA) Compressor --- AC starting current (LRA) Condenser fan --- AC power input (1) Condenser fan --- AC max. power input Condenser fan --- AC operative current (OA) (1) Condenser fan --- AC max. current (FLA) Condenser fan --- AC start---up current Evaporator fan --- AC power input (1) Evaporator fan --- AC operative current (OA) (1) Evaporator fan --- AC max. current (FLA) (2) Evaporator fan --- AC start---up current Evaporator air flow Condenser max. air flow Outdoor Sound Pressure Level (3) Indoor Sound Pressure Level (3) Max. ambient temperature (4) kW kW kW A A A kW kW A A A kW A A A m3/h m3/h dB(A) dB(A) _C 6.1 5.4 1.75 8.0 11.4 47.0 0.11 0.24 0.8 1.4 1.6 0.26 1.2 1.2 1.8 1510 2970 48.5 55 52 8.3 8.3 2.26 4.0 5.1 32.0 0.10 0.24 0.7 1.4 1.6 0.71 3.2 3.7 7.0 2670 2970 48.5 60 49.5 10.5 10.1 3.08 5.5 7.0 46.0 0.22 0.48 1.5 2.8 3.3 0.71 3.2 3.7 7.0 2670 6300 52.5 60 50.5 13.5 13.2 3.80 6.7 10.0 50.0 0.23 0.48 1.5 2.8 3.3 1.14 4.8 7.2 --- 3950 5675 53.5 62 49 14.7 13.6 4.76 8.7 10.2 63.0 0.28 0.48 1.7 2.8 3.3 1.14 4.8 7.2 --- 3950 5675 55.0 62 49 REFRIGERATION CIRCUITS Compressor --- type / quantity Refrigerant Expansion device Evaporator coil --- tubes / fins material Condenser coil --- tubes / fins material --- --- --- --- --- Scroll / 1 R407C Thermostatic expansion valve Copper / Aluminium Copper / Aluminium AIR FILTRATION Main air filter --- quantity / type Efficiency (CEN---EU) --- --- 1 / Pleated G3 Filters dimension mm 740/230/48 946 / 300 / 60 EVAPORATOR FAN Quantity / Type / Poles --- 2 coupled (single motor) / Centrifugal / 4 2 (2 motors) / Centrifugal / 4 Driven --- Direct CONDENSER FAN Quantity / Type / Poles --- 1 / Axial / 6 2 / Axial / 6 Driven / Motor protection --- Direct / IP54 Control system --- Variable speed ELECTRIC HEATING Type / Steps --- Tube / 1 Wires / 1 Heating capacity kW 3.0 6.0 Heating --- max. current A 6.5 8.7 CABINET Frame --- Galvanised steel Painting --- Polyester --- RAL7035 OVERALL DIMENSIONS Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 920 / 1190 / 390 Width / Height / Depth (SE_W indoor unit) mm 800/310/800 1100 / 395 / 1095 Weight (HPSC outdoor unit) kg 80 82 97 103 111 Weight (SE_W indoor unit) kg 54 110 120 Notes: (1) – Indoor reference conditions: 27˚C / 47% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply. (2) – Values referred to nominal speed (factory set). (3) --- Measured with outdoor temperature of 35˚C, at 2 m from the unit, in free field conditions. (4) --- Maximum outdoor temperature referred to 27˚C / 47% R.H. air intake. (*) --- HPSW 13 is composed by SE 13W + HPSC 12.
  • 23. Technical Data 7 -- 8Liebert HPS---PD---272965---20.11.2009 Tab. 8 --- SE_W + HPSC (Freecooling and AC emergency freecooling versions) MODEL: HPSW 06 08 10 13 (*) 14 Air supply --- Upflow Main power supply --- 230V ±10% / 1Ph / 50Hz 400V ±10% / 3Ph+N+PE / 50Hz Emergency power supply --- 230V ±10% / 1Ph / 50Hz PERFORMANCE Total cooling capacity (1) Sensible cooling capacity (1) Compressor --- AC power input (1) Compressor --- AC operative current (OA) (1) Compressor --- AC max current (FLA) Compressor --- AC starting current (LRA) Condenser fan --- AC power input (1) Condenser fan --- AC max. power input Condenser fan --- AC operative current (OA) (1) Condenser fan --- AC max. current (FLA) Condenser fan --- AC start---up current Evaporator fan --- AC power input (1) Evaporator fan --- AC operative current (OA) (1) Evaporator fan --- AC max. current (FLA) (2) Evaporator fan --- AC start---up current Evaporator air flow Freecooling air flow Condenser max. air flow Outdoor Sound Pressure Level (3) Indoor Sound Pressure Level (3) Max. ambient temperature (4) kW kW kW A A A kW kW A A A kW A A A m3/h m3/h m3/h dB(A) dB(A) _C 6.1 5.4 1.75 8.0 11.4 47.0 0.11 0.24 0.8 1.4 1.6 0.26 1.2 1.2 1.8 1510 1400 2970 48.5 55 52 8.3 8.3 2.26 4.0 5.1 32.0 0.10 0.24 0.7 1.4 1.6 0.71 3.2 3.7 7.0 2670 2230 2970 48.5 60 49.5 10.5 10.1 3.08 5.5 7.0 46.0 0.22 0.48 1.5 2.8 3.3 0.71 3.2 3.7 7.0 2670 2230 6300 52.5 60 50.5 13.5 13.2 3.80 6.7 10.0 50.0 0.23 0.48 1.5 2.8 3.3 1.14 4.8 7.2 --- 3950 3600 5675 53.5 62 49 14.7 13.6 4.76 8.7 10.2 63.0 0.28 0.48 1.7 2.8 3.3 1.14 4.8 7.2 --- 3950 3600 5675 55.0 62 49 REFRIGERATION CIRCUITS Compressor --- type / quantity Refrigerant Expansion device Evaporator coil --- tubes / fins material Condenser coil --- tubes / fins material --- --- --- --- --- Scroll / 1 R407C Thermostatic expansion valve Copper / Aluminium Copper / Aluminium AIR FILTRATION Main air filter --- quantity / type Efficiency (CEN---EU) --- --- 1 / Pleated G3 Filters dimension mm 740/230/48 946 / 300 / 60 EVAPORATOR FAN Quantity / Type / Poles --- 2 coupled (single motor) / Centrifugal / 4 2 (2 motors) / Centrifugal / 2 Driven --- Direct CONDENSER FAN Quantity / Type / Poles --- 1 / Axial / 6 2 / Axial / 6 Driven / Motor protection --- Direct / IP54 Control system --- Variable speed ELECTRIC HEATING Type / Steps --- Tube / 1 Wires / 1 Heating capacity kW 3.0 6.0 Heating --- max. current A 13.1 8.7 CABINET Frame --- Galvanised steel Painting --- Polyester --- RAL7035 OVERALL DIMENSIONS Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 920 / 1190 / 390 Width / Height / Depth (SE_W indoor unit) mm 800/310/1050 1100 / 395 / 1395 Weight (HPSC outdoor unit) kg 80 82 97 103 111 Weight (SE_W indoor unit) kg 62 122 132 Notes: (1) – Indoor reference conditions: 27˚C / 47% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply. (2) – Values referred to nominal speed (factory set). (3) --- Measured with outdoor temperature of 35˚C, at 2 m from the unit, in free field conditions. (4) --- Maximum outdoor temperature referred to 27˚C / 47% R.H. air intake. (*) --- HPSW 13 is composed by SE 13W + HPSC 12.
  • 24. Technical Data 7 -- 9Liebert HPS---PD---272965---20.11.2009 Tab. 9 --- SE_W + HPSC (Freecooling and DC emergency freecooling versions) MODEL: HPSW 06 08 10 13 (*) 14 Air supply --- Upflow Main power supply --- 230V ±10% / 1Ph / 50Hz 400V ±10% / 3Ph+N+PE / 50Hz Emergency power supply --- 48 VDC PERFORMANCE Total cooling capacity (1) Sensible cooling capacity (1) Compressor --- AC power input (1) Compressor --- AC operative current (OA) (1) Compressor --- AC max current (FLA) Compressor --- AC starting current (LRA) Condenser fan --- AC power input (1) Condenser fan --- AC max. power input Condenser fan --- AC operative current (OA) (1) Condenser fan --- AC max. current (FLA) Condenser fan --- AC start---up current Evaporator fan --- DC power input (1) Evaporator fan --- DC operative current (OA) (1) Evaporator fan --- DC max. current (FLA) (2) Evaporator fan --- DC start---up current Evaporator air flow Freecooling air flow Condenser max. air flow Outdoor Sound Pressure Level (3) Indoor Sound Pressure Level (3) Max. ambient temperature (4) kW kW kW A A A kW kW A A A kW A A A m3/h m3/h m3/h dB(A) dB(A) _C 6.1 5.4 1.75 8.1 11.4 47.0 0.11 0.24 0.8 1.4 1.6 0.14 3.0 6.0 0.1 1510 1400 2970 48.5 55 52 8.3 8.3 2.26 4.0 5.1 32.0 0.14 0.24 0.8 1.4 1.6 0.38 7.9 16.8 0.1 2670 2230 2970 48.5 60 49.5 10.5 10.1 3.08 5.5 7.0 46.0 0.22 0.48 1.5 2.8 3.3 0.38 7.9 16.8 0.1 2670 2230 6300 52.5 60 50.5 13.5 13.2 3.80 6.7 10.0 50.0 0.23 0.48 1.5 2.8 3.3 0.82 16.8 16.8 0.1 3950 3600 5675 53.5 62 49 14.7 13.6 4.76 8.7 10.2 63.0 0.28 0.48 1.7 2.8 3.3 0.82 16.8 16.8 0.1 3950 3600 5675 55.0 62 49 REFRIGERATION CIRCUITS Compressor --- type / quantity Refrigerant Expansion device Evaporator coil --- tubes / fins material Condenser coil --- tubes / fins material --- --- --- --- --- Scroll / 1 R407C Thermostatic expansion valve Copper / Aluminium Copper / Aluminium AIR FILTRATION Main air filter --- quantity / type Efficiency (CEN---EU) --- --- 1 / Pleated G3 Filters dimension mm 740/230/48 946 / 300 / 60 EVAPORATOR FAN Quantity / Type / Poles --- 2 / Plug / --- Driven --- Direct CONDENSER FAN Quantity / Type / Poles --- 1 / Axial / 6 2 / Axial / 6 Driven / Motor protection --- Direct / IP54 Control system --- Variable speed ELECTRIC HEATING Type / Steps --- Tube / 1 Wires / 1 Heating capacity kW 3.0 6.0 Heating --- max. current A 13.1 8.7 CABINET Frame --- Galvanised steel Painting --- Polyester --- RAL7035 OVERALL DIMENSIONS Width / Height / Depth (HPSC outdoor unit) mm 920 / 840 / 390 920 / 1190 / 390 Width / Height / Depth SE_W indoor unit) mm 800/310/1050 1100 / 395 / 1395 Weight (HPSC outdoor unit) kg 80 82 97 103 111 Weight (SE_W indoor unit) kg 62 122 132 Notes: (1) – Indoor reference conditions: 27˚C / 47% R.H. air intake. Outdoor reference conditions: 35˚C. Nominal power supply. (2) – Values referred to nominal speed (factory set). (3) --- Measured with outdoor temperature of 35˚C, at 2 m from the unit, in free field conditions. (4) --- Maximum outdoor temperature referred to 27˚C / 47% R.H. air intake. (*) --- HPSW 13 is composed by SE 13W + HPSC 12.
  • 25. 8DimensionalDrawings 8--1LiebertHPS---PD---272965---20.11.2009 Fig.4---EvaporatingunitHPSE06(versionwithfreecooling) Condensatedrain 228150150150125 13,5 833 13,5 803 251,5300251,5 310 155 155 28.528.5803 310 FRONTVIEW(CIRCULARDUCTSVERSION) TOPVIEW LEFTSIDEVIEW RIGHTSIDEVIEW N.8slots9x12--- unitfixing N.2collars ø200H=35mm Refrigerant connection Electrical connection 803 70994 14.5 120,5562120,5 5919259 310 80328,528,5 FRONTVIEW(RECTANGULARDUCTVERSION) Refrigerant connection Collar 190x560H=35mm 860
  • 29. Dimensional Drawings Liebert HPS---PD---272965---20.11.2009 8 -- 5 Fig. 8 --- Evaporating unit SE 06W (version with freecooling) Condensate drain Condensate drain N.6 HOLES 4 8 250800 3506035040 310 Circular ducts version 310 185125 N.2 COLLARS 4 200 HEIGHT 35 mm COLLAR 190 X 560 HEIGHT 35 mm 310 9019030 Rectangular duct version 83412 12 800 2929 1050 300 280220 560 15090 BOTTOM VIEW BOTTOM VIEW REAR VIEW SIDE VIEW TOP VIEW Refrigerant outlet Refrigerant inlet Refrigerant outlet Refrigerant inlet Electrical connections
  • 30. Dimensional Drawings Liebert HPS---PD---272965---20.11.2009 8 -- 6 Fig. 9 --- Evaporating unit SE 06W (version without freecooling) 800 80029 29 83412 12 N.6 HOLES ø8 800 3506035040310 BOTTOM VIEW REAR VIEW SIDE VIEW TOP VIEW Condensate drain Refrigerant outlet Refrigerant inlet Electrical connections
  • 31. Dimensional Drawings Liebert HPS---PD---272965---20.11.2009 8 -- 7 Fig. 10 --- Evaporating unit SE 08--10--13--14W (version with freecooling) Condensate drainCondensate drain Refrigerant inlet Refrigerant inlet 2951100 3209032032050 395 395 220175220175 9550 N.2 COLLARS 4 250 HEIGHT 35 mm N.8 HOLES 4 8 310 350 395 250 185 600 270 1395 30 1055 30 395 COLLAR 250 X 600 HEIGHT 35 mm Circular ducts version Rectangular duct version BOTTOM VIEW REAR VIEW SIDE VIEW TOP VIEW BOTTOM VIEW Electrical connections Refrigerant outlet Refrigerant outlet
  • 32. Dimensional Drawings Liebert HPS---PD---272965---20.11.2009 8 -- 8 Fig. 11 --- Evaporating unit SE 08--10--13--14W (version without freecooling) 1100 BOTTOM VIEW SIDE VIEW TOP VIEW Refrigerant inlet Condensate drain Refrigerant outlet N.8 HOLES 4 8 Electrical connections 400 1052 3434 1100 3209032050320 1086 1717 400 REAR VIEW
  • 35. 9 Installation 9 -- 1Liebert HPS---PD---272965---20.11.2009 Fig. 14 --- HPSE 06--08--10--12--14 evaporating unit ceiling installation (version without freecooling) min.200 min. 300 803 (HPSE 06--08--10) Service area for electical board 903 (HPSE 12--14) 310(HPSE06--08--10) 375(HPSE12--14) Ceiling fixing points
  • 36. Installation 9 -- 2Liebert HPS---PD---272965---20.11.2009 Fig. 15 --- HPSE 06--08--10--12--14 evaporating unit installation (version with freecooling) HPSE A B C 06 min. 300 803 310 08---10---12---14 min. 320 903 375 ITEM DESCRIPTION 1 Electrical box accessibility 2 Support for filter 3 Air filter 4 Freecooling filter accessibility 5 Electrical box 1 2 3 4 3 3 5 min.200 min. 300 Service area for electical board Servicearea forFreecooling filter A B C
  • 37. Installation 9 -- 3Liebert HPS---PD---272965---20.11.2009 Fig. 16 --- HPSE 06--08--10--12--14 evaporating unit ceiling installation (version with freecooling) 231 4 5 5 867 11 910 ITEM DESCRIPTION COD. HPSE 06 COD. HPSE 08---10---12---14 1 Wall plate for circular duct 13503801 13536101 2 2 flexible ducts with fixing clamps, L = 0.5 m 270190 (ø 202mm) 270191 (ø 254mm) 3 Fixing clamps --- --- 4 Wall plate for rectangular duct 13501801 13536001 5 Circular / rectangular version --- --- 6 Wall hole 400 x 200mm 600 x 400mm 7 Overpressure damper 134948 134992 8 Grille for overpressure damper 270206 117832 9 Aluminium grille with metallic prefilter 270202 270219 10 Metallic prefilter (included in item 9) --- --- 11 Wall hole 550 x 210mm 590 x 230mm
  • 38. Installation 9 -- 4Liebert HPS---PD---272965---20.11.2009 Fig. 17 --- SE 06--08--10--13--14W service area CB D A B C DA 200 300 300 0 200 100 0 0 VERSION WITH FREECOOLING VERSION WITHOUT FREECOOLING E 700 700 E B C Fig. 18 --- SE 06--08--10--13--14W evaporating unit wall installation 1050(SE06W) 1550(SE06W) min.500 1395(SE08---10---13---14W) 1895(SE08---10---13---14W) AIRRETURN AIR CONDITIONED OUTSIDEAIR 800(SE06W)min.200 1000(SE06W) 1100(SE08---10---13---14W) 1300(SE08---10---13---14W) AIR CONDITIONED AIRRETURN With freecooling option Without freecooling option
  • 39. Installation 9 -- 5Liebert HPS---PD---272965---20.11.2009 Fig. 19 --- SE 06--08--10--13--14W evaporating unit wall installation (version with freecooling) 1 2 9 8 10 7 6 4 3 5 11 10 8 9 ITEM DESCRIPTION CODE SE 06W SE 08---10---13---14W 1 SE_W with FC option (optional rectangular hole) --- --- 2 SE_W with FC option (standard circular hole) --- --- 3 Overpressure damper 134948 134992 4 Grille for overpressure damper 270206 117832 5 Hole in the wall 400 x 200 mm 600 x 400 mm 6 2 FC flexible ducts L=0.5 m, with fixing clamps 270190 (∅ 202) 270191 (∅ 254) 7 Wall plate for FC circular duct 13503801 13536101 8 Aluminium grille with metallic prefilter 270202 270219 9 Metallic prefilter (included in (8) --- --- 10 Hole in the wall 550 x 210 mm 590 x 230 mm 11 Wall plate for FC rectangular duct 13501801 13536001
  • 40. Installation 9 -- 6Liebert HPS---PD---272965---20.11.2009 Fig. 20 --- HPSC 06--08--10--12--14 condensing unit installation components 1 2 3 4 1 2 3 5 HPSC 06---08 HPSC 10---12---14 ITEM DESCRIPTION 1 Nut 2 Serrated lock washer 3 Washer 4 Anti---vibrating mount 5 Bracket
  • 41. Installation 9 -- 7Liebert HPS---PD---272965---20.11.2009 Fig. 21 --- HPSC 06--08--10--12--14 service and working area 1 3 4 5 2 If H1 < 0.5 x H2 ⇒ L min. = 500 mm. . . . . . . . . If 0.5 x H2 ≤ H1 ≤ H2 ⇒ L min. = 800 mm. . . If H1 > H2 ⇒ Not allowable configuration. . . . . . . . . . . . . . 5 WALL IN FRONT OF UNITS WALL IN FRONT OF UNITS WALL BEHIND UNITS WALL BEHIND UNITS MULTI---ROWS INSTALLATION
  • 42. Installation 9 -- 8Liebert HPS---PD---272965---20.11.2009 Fig. 22 --- Liebert HPS (HPSE + HPSCxx0/A) suggested refrigerant connections HPSE (Internal Unit) Gas pipeline (Sloping 1%) Liquid/gas pipeline 10 m max. horizontal equivalent length Gas pipeline (Sloping 1%) Gas pipeline (Sloping 1%) HPSE (Internal Unit) HPSE (Internal Unit) 7 m max. horizontal equivalent length A 5mmax.vertical distancebetween twosyphons 3mmax. verticaldistance Syphons (obligatory) NOTE: Max. equivalent length for refrigerant line A + B = 10 m HPSC (External Unit) Gas pipeline (Sloping 1%) HPSC (External Unit) HPSC (External Unit) Gas pipeline (Sloping 1%) B Liquid/gas pipeline Liquid/gas pipeline
  • 43. Installation 9 -- 9Liebert HPS---PD---272965---20.11.2009 Fig. 23 --- Liebert HPS (HPSE + HPSCxxL, Long piping) suggested refrigerant connections 5mmax.vertical distancebetween twosyphons 5mmax.vertical distancebetween twosyphons HPSE (Internal Unit) Gas pipeline (Sloping 1%) 50 m max. horizontal equivalent length Gas pipeline (Sloping 1%) Gas pipeline (Sloping 1%) Gas pipeline (Sloping 1%) Gas pipeline (Sloping 1%) HPSE (Internal Unit) HPSE (Internal Unit) 30 m max. horizontal equivalent length 30 m max. horizontal equivalent length 20mmax. verticaldistance 20mmax.verticaldistance Syphons (obligatory) HPSC (External Unit) HPSC (External Unit) HPSC (External Unit) Liquid/gas pipeline Liquid/gas pipeline Liquid/gas pipeline
  • 44. Installation 9 -- 10Liebert HPS---PD---272965---20.11.2009 Fig. 24 --- Liebert HPSW (SE_W + HPSCxxA) suggested refrigerant connections 5mmax. vertical distance between twosyphons Gas pipeline (Sloping 1%) NOTE: Max. equivalent length for refrigerant line A + B = 10 m Gas pipeline (Sloping 1%) 10 m max. horizontal equivalent length Gas pipeline (Sloping 1%) SE_W (Internal Unit) 7 m max. horizontal equivalent length A Syphons (obligatory) HPSC (External Unit) Gas pipeline (Sloping 1%) HPSC (External Unit) Gas pipeline (Sloping 1%) SE_W (Internal Unit) B SE_W (Internal Unit) 3mmax. verticaldistance HPSC (External Unit) Liquid/gas pipeline Liquid/gas pipeline Liquid/gas pipeline
  • 45. Installation 9 -- 11Liebert HPS---PD---272965---20.11.2009 Fig. 25 --- Liebert HPSW (SE_W + HPSCxxL, Long piping) suggested refrigerant connections Gas pipeline (Sloping 1%) 50 m max. horizontal equivalent length Gas pipeline (Sloping 1%) Gas pipeline (Sloping 1%) SE_W (Internal Unit) 30 m max. horizontal equivalent length Syphons (obligatory) HPSC (External Unit) Gas pipeline (Sloping 1%) HPSC (External Unit) Gas pipeline (Sloping 1%) SE_W (Internal Unit) 5mmax. verticaldistance between twosyphons 5mmax. vertical distance between twosyphons SE_W (Internal Unit) 20mmax. verticaldistance HPSC (External Unit) 20mmax. verticaldistance 30 m max. horizontal equivalent length Liquid/gas pipeline Liquid/gas pipeline Liquid/gas pipeline
  • 46.
  • 47. PrintedinItalybyLiebertHIROSSS.pA. IssuedbyT.D.Service Since the Liebert HIROSS Company has a policy of continuous product improvement, it reserves the right to change design and specifications without previous notice. Il Fabbricante dichiara che questo prodotto è conforme alle direttive Europee: The Manufacturer hereby declares that this product conforms to the European Union directives: Der Hersteller erklärt hiermit, dass dieses Produkt den Anforderungen der Europäischen Richtlinien gerecht wird: Le Fabricant déclare que ce produit est conforme aux directives Européennes: El Fabricante declara que este producto es conforme a las directivas Europeas: O Fabricante declara que este produto está em conformidade com as directivas Europeias: Tillverkare försäkrar härmed att denna produkt överensstämmer med Europeiska Uniones direktiv: De Fabrikant verklaart dat dit produkt conform de Europese richtlijnen is: Vaimistaja vakuuttaa täten, että tämä tuote täyättää seuraavien EU---direktiivien vaatimukset: Produsent erklærer herved at dette produktet er i samsvar med EU---direktiver: Fabrikant erklærer herved, at dette produkt opfylder kravene i EU direktiverne: Ο Κατασ◶ευαστ δhλ νει τι τo πα◽ ν π◽oΪ ν ε ναι ◶ατασ◶ευασ νo α φwνα ε τι oδhγ ε τh Ε.Ε.: 2006/42/EC; 2004/108/EC; 2006/95/EC; 97/23/EC
  • 48. While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and accepts no liability for damages resulting from use of this information or for any errors or omissions. ©2008 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader in enabling Business-Critical Continuity™ from grid to chip for telecommunication networks, data centers, health care and industrial facilities. Emerson Network Power provides innovative solutions and expertise in areas including AC and DC power and precision cooling systems, embedded computing and power, integrated racks and enclosures, power switching and controls, monitoring, and connectivity. All solutions are supported globally by local Emerson Network Power service technicians. Liebert power, precision cooling and monitoring products and services from Emerson Network Power improve the utilization and management of data center and network technologies by increasing IT system availability, flexibility and efficiency. For more information, visit www.liebert.com, www.emersonnetworkpower. com or www.eu.emersonnetworkpower.com Locations Emerson Network Power - Headquarters EMEA Via Leonardo Da Vinci 16/18 Zona Industriale Tognana 35028 Piove di Sacco (PD) Italy Tel: +39 049 9719 111 Fax: +39 049 5841 257 marketing.emea@emersonnetworkpower.com Emerson Network Power - Service EMEA Via Leonardo Da Vinci 16/18 Zona Industriale Tognana 35028 Piove di Sacco (PD) Italy Tel: +39 049 9719 111 Fax: +39 049 9719045 service.emea@emersonnetworkpower.com United States 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Tel: +1 614 8880246 Asia 7/F, Dah Sing Financial Centre 108 Gloucester Road,Wanchai Hong Kong Tel: +852 2572220 Fax: +852 28029250 Ensuring The High Availability Of Mission-Critical Data And Applications. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Control Precision Cooling Rack & Integrated Cabinets Services Surge Protection Emerson Network Power The global leader in Business-Critical Continuity™. Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of EmersonElectric Co. ©2008 Emerson Electric Co.