Sensor Characteristics (Typical Values)
General-purpose sensor
-60
120
100
80
60
40
20
-40 -20 0 20 40 60
deg
82311B Incident angle dependence
(780nm)
P polarization
S polarization
Circular polarization
P polarization
S polarization
Circular polarization
0
50
40
30
20
10
0
10 20 30 40 50 60
deg
82311B Reflectance (780nm)
1
2
0
-2
-4
-6
-8
-10
10 100
Incident Power [mW]
82311B/82321B Power linearity
(780nm)
Beamφ0.1
Beamφ0.7
Beamφ3
Linearuty(%)
Reflectance(%)
380
140
120
100
80
60
40
20
0
580 780 980
wavelength [nm]
82311B/82321B Wavelength sensitivity
Sensitivity(%)
Sensitivity(%)
-60
120
100
80
60
40
20
-40 -20 0 20 40 60
deg
82312B/82322B Incident angle dependence
(405nm)
P polarization
S polarization
Circular polarization
P polarization
S polarization
Circular polarization
0
50
40
30
20
10
0
10 20 30 40 50 60
deg
82312B/82322B Reflectance
(405nm)
1
2
0
-2
-4
-6
-8
-10
10 100
Incident Power [mW]
82312B/82322B Power linearity
(405nm)
Beamφ0.1
Beamφ0.7
Linearuty(%)
Reflectance(%)
400
101
100
99
98
97
95
0
405 410 415 420
wavelength [nm]
82312B/82322B Wavelength sensitivity
Sensitivity(%)
Sensitivity(%)
-60
120
100
80
60
40
20
-40 -20 0 20 40 60
deg
82313B/82323B Incident angle dependence
(780nm)
P polarization
S polarization
Circular polarization
0
50
40
30
20
10
0
10 20 30 40 50 60
deg
82313B/82323B Reflectance
(780nm)
P polarization
S polarization
Circular polarization
1
2
0
-2
-4
-6
-8
-10
10 100 1000
Incident Power [mW]
82313B/82323B Power linearity Beamφ0.1
Beamφ0.7
Linearuty(%)
Reflectance(%)
380
140
120
100
80
60
40
20
0
580 780 980 1180
wavelength [nm]
82313B/82323B Wavelength sensitivity
Sensitivity(%)
Sensitivity(%)
Blue-violet sensor
High-power sensor
Sensor Characteristics (Typical Values)
Three-wavelength sensor
0
120
100
80
60
40
20
10 20 30 40 50 60
deg
82314B/82314BW/32324B
Incident angle dependence (405nm)
0
30
40
50
20
10
0
10 20 30 40 50 60
deg
82314B/82314BW/32324B
Reflectance (405nm)
400
105
104
103
102
101
100
99
98
97
96
95
405 410 420
415
82314B/82314BW/32324B
Wavelength sensitivity (405nm)
Reflectance(%)
wavelength [nm]
Sensitivity(%)
Sensitivity(%)
390
140
120
100
80
60
40
20
0
490 590 890
690 790
82314B/82314BW/32324B
Wavelength sensitivity (all levels)
wavelength [nm]
Sensitivity(%)
P polarization
S polarization
Circular polarization
P polarization
S polarization
Circular polarization
Dimensional Drawing
10
18
180
11
18
180
99
∗
5
受光素子面までの距離0.5mm
3.2
保護硝子面までの距離0.8mm
受光素子面までの距離1.8mm
3.2
Distance to the cover glass surface: 0.8mm
Distance to the light receiving element surface: 1.8mm
(8.5)
10
18
180
99
72.5
82311B
82312B/82313B
82314B
∗: Fixing screw hole
M3 (5mm max.)
∗:Fixing screw hole
M3 (5mm max.)
∗:Fixing screw hole
M3 (6mm max.)
3.7
Distance to the cover glass surface: 0.1mm
Distance to the light receiving element surface: 1.4mm
Distance to the light
receiving element surface: 2.15mm
Distance to the cover
glass surface: 0.65mm
M33×1.5
φ 38
φ14
17.55
197
35.1
∗
∗
82314BW 82324B
(8.5)
76
1500
72.5
40
35
28
5
11
18
180
82313B
82312B
82314B
5
Distance to the light receiving
element surface: 0.5mm
11
18
3.7
Distance to the cover glass surface: 0.1mm
Distance to the light receiving element surface: 1.4mm
11
18
3.7
Distance to the cover glass
surface: 0.3mm
Distance to the light receiving
element surface: 1.4mm
11
18
82312B/3B
82314B
8230
Optical Power Meter
Perfect for use in R&D and production lines of next-
generation optical discs and for evaluation of blue-
violet and high-power lasers
l	 A wide selection of optical sensors for different use
l	Three-wavelength optical sensors covering 405/650/780nm
l	Blue-violet optical sensors for 405nm laser measurement
l	High-power optical sensors for high-power laser measurement
l	Low-price general-purpose optical sensors
l		Both thin type and cylindrical type available
l	 Optical power calibration wavelengths: 405/650/780nm
l	 5½-digit display and 0.001dB resolution
l	 USB interface
http://www.adcmt-e.com
82311B
82321B
82312B
82322B
82313B
82323B
82314B
82324B
82314BW
405
nm
405
nm
650
nm
650
nm
780
nm
780
nm
2 3 4
200mW with high accuracy. These sensors have high linearity up to
200mW approximately even at beam spot of 0.1mm diameter.
200mW
● Low-priced and easy-to-use general-purpose
sensors
The 82311B and the 82321B are low-price general-purpose sen-
sors that can be used in a wide wavelength range from 390nm to
1100nm.
The calibration wavelength is 780nm and the correction value is
stored in the sensors. Sensitivity correction of other wavelengths
is also available by using the options.
● Both thin types and cylindrical types
Two shapes of sensors can be selected for each purpose. Thin
types of sensors are convenient for measuring optical power in
a limited space with a pickup installed, and cylindrical types of
sensors are used for measuring the output power from a fiber with
an optical bench.
● Blue-violet sensors to measure lasers of Blu-ray
Disc
To measure blue-violet lasers precisely, the 82312B and 82322B
blue-violet sensors have realized a maximally flat wavelength sen-
sitivity characteristic. This saves time in performing sensitivity
correction at each measurement and always offers high-accuracy
measurement results.
405nm (Blu-ray)
● Three-wavelength sensors to measure lasers
with different wavelengths
The 82314B, 82324B and 82314BW sensors are capable of mea-
suring all lasers of 405nm wavelength for Blu-ray Disc, 650 nm
wavelength for DVD and 780nm wavelength for CD. In the range
from 400 to 420nm wavelengths in particular, sensitivity cor-
rection is unnecessary because of the flat wavelength sensitivity
characteristic. In other wavelength ranges, the wavelength sensi-
tivity values stored in the sensor help easy operation.
405nm 650nm 780nm
● High-power sensors to measure high-power la-
sers for write
The power output of a laser disc for write such as CD-RW exceeds
100mW at the peak even with a pickup installed. The 82313B and
the 82323B are high-power sensors capable of measuring up to
Specifications
All accuracies are guaranteed for one year at a temperature of +23 ± 5°C and a relative humidity of 70% or less.
Sensor Specifications (Sold Separately)
*1: Relative sensitivity to the center is within the ±10% range.	 *2: Can be added by using options.	 *3: For the 82311B or 82321B, Option+20 is specified.
*4: The warranty does not include cut cables and/or damaged or degraded elements caused by connecting and disconnecting the sensor section.	
■ Nine Types of Optical Sensors to Meet Various Applications
The 8230 is an optical power meter optimal for building up automated
production lines of Blu-ray Disc, DVD, CD and other optical pickups.
It is equipped with a USB interface as standard, which allows easy
establishment of automated systems at a low price without adding any
external unit.
In addition, the latest USB driver is available from our website to make
your operation easier.
■ Ideal for Making Automated Systems
• Please read through the operation manual carefully before using the products.
• All specifications are subject to change without notice.
Instrument Specifications
Display resolution: 0.1pW (display in W), 0.001dB (display in dBm)
Accuracy: The following is added to the accuracy of
each sensor.
(Within 24 hours after offset zero execu-
tion, unit: W)
20nW range ±(0.55% + 2000 digits)
200nW range ±(0.15% + 200 digits)
2μW to 200mW range ±(0% + 70 digits)
Display: LCD with three-level backlight
Wavelength display: 4 digits
Power display: 5½ digits (Unit: mW, μW, nW, dBm, dBr)
Bar graph display
Range switching: 8 ranges; auto, manual and remote
Sampling rate: 5 readings/sec or more
Wavelength sensitivity
correction:
Automatic correction of sensor wavelength
sensitivity by wavelength setting (in 1nm step)
Offset zero: Sensor offset stored in the memory for
automatic correction
Relative value display function: Ratio (display in W), dBr (display in dBm)
Analog output: Analog output according to the input signal *5
Output voltage: 0 to 2V, output resistance: 10Ω or less
Output connector: 2P mini-jack (3.5mm dia.)
USB interface: USB 2.0 Full-Speed compliant (connector
mini B/female)
Auto power off: Powers off approximately 30 minutes
after any key operation or remote opera-
tion is not performed. (Function can be
set ON or OFF.)
Backup function: Stores four setting conditions.
Smoothing function: Moving average from 2 to 100 times
Max value hold function: Holds the maximum measured value.
Calibration wavelength
selection function:
Available only with calibration wave-
length option(s) installed
Wavelength preset function *6
: Registers four wavelengths of which
sensitivity is corrected.
Other functions: CF calculation (sets one correction coefficient for
measured values.)
Display digit selection, key lock, and battery check
General Specifications
Operating environment: Ambient temperature: 0ºC to +40ºC
Relative humidity:80% or less, no condensation
Storage environment: Ambient temperature: -20ºC to +70ºC
Relative humidity:80% or less, no condensation
Warm-up time: 30 minutes or more (until the specified
accuracy is reached.)
Power supply
Battery drive: AA battery × 4 *7
Service life: 60 hours (with 1mW or less power, with
back light OFF, using the alkaline battery,
and at +23ºC±5ºC)
DC input: 9V 100mA or less
AC adapter: 100-240VAC
Line frequency: 50/60Hz
Power consumption: 100-120V: 5VA or less, 220-240V: 10VA or less
(when the supplied AC adapter is used.)
Dimensions: Approx. 80 (W) × 180 (H) × 40 (D) mm
Mass: 300g or less (excluding AA batteries)
Supplied Accessories
AC adapter (100-240VAC):		 A146001
Optional Accessories
USB cable	
(1m USB A/male-mini B/male):	 A112010
Analog output cable (1m):	 A01225
FC adapter (for 82321B/82322B/82323B/82324B):	 A08012
Power cable (UL/CSA):	 CC014001
Power cable (EN):	 CC014002
Power cable (CCC):	 CC014003
Wavelength Sensitivity Correction Option and Calibration Wavelength Option
Wavelength sensitivity correction option:
The wavelength sensitivity of each sensor is measured and corrected when
calibrating. (The 82311B/82321B of the standard specification is corrected
by using the typical value.)
Calibration wavelength option:
The calibration is performed at wavelengths other than the standard
specification. (Multiple wavelengths can be specified.)
*7: Use alkaline batteries only. Batteries are not included.
*5: The full-scale value varies depending on the sensor model, wavelength setting, cor-
rection value (CF), and range setting.
*6: This function is available when the software revision is B00 or later.
Optical power meter software revisions and applicable optical sensors
In addition to the optical sensors described in this brochure, discontinued
products 82311, 82312, 82313, 82314A, 82314W, 82321, 82322,
82323 and 82324A can be used.
The following table shows software revisions required for optical sensor operations.
Optical sensor Software revision
82311B D01 or later
82312B D01 or later
82313B D01 or later
82314B D01 or later
82314BW D01 or later
82321B D01 or later
82322B D01 or later
82323B D01 or later
82324B D01 or later
Optical sensor Software revision
82311 A00 or later
82312 A00 or later
82313 A00 or later
82314A B01 or later
82314W B01 or later
82321 A00 or later
82322 A00 or later
82323 A00 or later
82324A B01 or later
Thin-type sensor Cylindrical-type sensor
Option 82311B 82312B 82313B
Wavelength sensitivity correction OPT82311B+20 Standard specification Standard specification
Calibration
wavelength
405nm OPT82311B+21 Standard specification OPT82313B+21
650nm OPT82311B+22 − Standard specification
780nm Standard specification − OPT82313B+23
Option 82321B 82322B 82323B
Wavelength sensitivity correction OPT82321B+20 Standard specification Standard specification
Calibration
wavelength
405nm OPT82321B+21 Standard specification OPT82323B+21
650nm OPT82321B+22 − Standard specification
780nm Standard specification − OPT82323B+23
Option 82314B 82314BW 82324B
Wavelength sensitivity correction Standard specification Standard specification Standard specification
Calibration
wavelength
405nm Standard specification Standard specification Standard specification
650nm OPT82314B+22 OPT82314BW+22 OPT82324B+22
780nm OPT82314B+23 OPT82314BW+23 OPT82324B+23
Option Standard Opt.94 Opt.95 Opt.96
Applicable standard JIS CCC UL/CSA EN
Rated 125V/7A 250V/2.5A 125V/3A 250V/2.5A
If the software revision of your optical power meter is other than the above, the applicable
software to be installed can be downloaded from our website. For more information, please visit
our website.
USB interface
Analog output
DC input (9V)
Data acquisition and control with PC
Key lock function
Linear (W) and log (dBm) display function
5½ wide dynamic range display
Battery indicator
Wavelength sensitivity
correction function
Absolute value (dBr)
(Ratio) display function
Bar graph display
Setting wavelength display
Smoothing function
Backlight
1nm step setting
Three levels of
luminance
adjustment
Model 82311B (General-purpose) 82312B (Blue-violet) 82313B (High-power)
Wavelength range 390 to 1100nm 390 to 450nm 390 to 1100nm
Power range
Display in dBm -60 to +17dBm -50 to +20dBm −50 to +23dBm
Display in W 1nW to 50mW 10nW to 100mW 10nW to 200mW
Beam spot 3mm dia. or more 1mm dia. or more 0.1mm dia. or more
Light receiving element Si Photodiode
Light receiving area Approx. 9.5mm × 9.5mm Approx. 10mm × 10mm Approx. 8.5mm dia.
Effective light receiving area *1
Approx. 8.5mm x 8.5mm Approx. 6mm dia.
Calibration wavelength *2
780nm 405nm 650nm
Measurement accuracy (at 1mW input)
±2.5% (at calibration wavelength)
(±3.5%)*3
(400 to 1000nm) ±3.5% (390 to 450nm) ±3.5% (400 to 1000nm)
Wavelength sensitivity correction range 390 to 1100nm 390 to 450nm 390 to 1100nm
Shape Thin type
Separation from a sensor section *4
Impossible Possible Possible
Dimensions (width) × (height) × (thickness of
the light receiving section) mm
18×180×3.2 18×180×3.7 18×180×5
Model 82321B (General-purpose) 82322B (Blue-violet) 82323B (High-power)
Wavelength range 390 to 1100nm 390 to 450nm 390 to 1100nm
Power range
Display in dBm -60 to +17dBm -50 to +20dBm −50 to +23dBm
Display in W 1nW to 50mW 10nW to 100mW 10nW to 200mW
Beam spot 3mm dia. or more 1mm dia. or more 0.1mm dia. or more
Light receiving element Si Photodiode
Light receiving area Approx. 8.5mm dia.
Effective light receiving area *1
Approx. 6.5mm dia. Approx. 6mm dia.
Calibration wavelength *2
780nm 405nm 650nm
Measurement accuracy (at 1mW input)
±2.5% (at calibration wavelength)
(±3.5%)*3
(400 to 1000nm) ±3.5% (390 to 450nm) ±3.5% (400 to 1000nm)
Wavelength sensitivity correction range 390 to 1100nm 390 to 450nm 390 to 1100nm
Shape Cylindrical type
Dimensions (width) × (height) mm 38×40
Model 82314B/82314BW (Three-wavelength)
Wavelength range 390 to 900nm
Wavelength 405nm 650nm 780nm
Power range
Display in dBm −50 to +20dBm
Display in W 10nW to 100mW
Beam spot 1mm dia. or more / 2mm dia. or more 3mm dia. or more
Light receiving element Si Photodiode
Light receiving area Approx. 10mm × 10mm / Approx. 18mm × 18mm
Effective light receiving area *1
Approx. 9.5mm × 9.5mm / Approx. 15.5mm × 15.5mm
Calibration wavelength *2
Standard
OPT82314B+22/
OPT82314BW+22
OPT82314B+23/OPT82314BW+23
Measurement accuracy (at 1mW input)
±2.5% (at calibration wavelength)
±3.5% (390 to 900nm)
Wavelength sensitivity correction range 390 to 900nm
Shape Thin type
Separation from a sensor section*4
Possible
Dimensions (width) × (height) × (thickness of
the light receiving section) mm
18×180×3.7/35.1×197×3.7
Model 82324B (Three-wavelength)
Wavelength range 390 to 900nm
Wavelength 405nm 650nm 780nm
Power range
Display in dBm −50 to +20dBm
Display in W 10nW to 100mW
Beam spot 1mm dia. or more 3mm dia. or more
Light receiving element Si Photodiode
Light receiving area Approx. 8.5mm dia.
Effective light receiving area *1
Approx. 6.5mm dia.
Calibration wavelength *2
Standard OPT82324B+22 OPT82324B+23
Measurement accuracy (at 1mW input)
±2.5% (at calibration wavelength)
±3.5%(390 to 900nm)
Wavelength sensitivity correction range 390 to 900nm
Shape Cylindrical type
Dimensions (width) × (height) mm 38×40
2 3 4
200mW with high accuracy. These sensors have high linearity up to
200mW approximately even at beam spot of 0.1mm diameter.
200mW
● Low-priced and easy-to-use general-purpose
sensors
The 82311B and the 82321B are low-price general-purpose sen-
sors that can be used in a wide wavelength range from 390nm to
1100nm.
The calibration wavelength is 780nm and the correction value is
stored in the sensors. Sensitivity correction of other wavelengths
is also available by using the options.
● Both thin types and cylindrical types
Two shapes of sensors can be selected for each purpose. Thin
types of sensors are convenient for measuring optical power in
a limited space with a pickup installed, and cylindrical types of
sensors are used for measuring the output power from a fiber with
an optical bench.
● Blue-violet sensors to measure lasers of Blu-ray
Disc
To measure blue-violet lasers precisely, the 82312B and 82322B
blue-violet sensors have realized a maximally flat wavelength sen-
sitivity characteristic. This saves time in performing sensitivity
correction at each measurement and always offers high-accuracy
measurement results.
405nm (Blu-ray)
● Three-wavelength sensors to measure lasers
with different wavelengths
The 82314B, 82324B and 82314BW sensors are capable of mea-
suring all lasers of 405nm wavelength for Blu-ray Disc, 650 nm
wavelength for DVD and 780nm wavelength for CD. In the range
from 400 to 420nm wavelengths in particular, sensitivity cor-
rection is unnecessary because of the flat wavelength sensitivity
characteristic. In other wavelength ranges, the wavelength sensi-
tivity values stored in the sensor help easy operation.
405nm 650nm 780nm
● High-power sensors to measure high-power la-
sers for write
The power output of a laser disc for write such as CD-RW exceeds
100mW at the peak even with a pickup installed. The 82313B and
the 82323B are high-power sensors capable of measuring up to
Specifications
All accuracies are guaranteed for one year at a temperature of +23 ± 5°C and a relative humidity of 70% or less.
Sensor Specifications (Sold Separately)
*1: Relative sensitivity to the center is within the ±10% range.	 *2: Can be added by using options.	 *3: For the 82311B or 82321B, Option+20 is specified.
*4: The warranty does not include cut cables and/or damaged or degraded elements caused by connecting and disconnecting the sensor section.	
■ Nine Types of Optical Sensors to Meet Various Applications
The 8230 is an optical power meter optimal for building up automated
production lines of Blu-ray Disc, DVD, CD and other optical pickups.
It is equipped with a USB interface as standard, which allows easy
establishment of automated systems at a low price without adding any
external unit.
In addition, the latest USB driver is available from our website to make
your operation easier.
■ Ideal for Making Automated Systems
• Please read through the operation manual carefully before using the products.
• All specifications are subject to change without notice.
Instrument Specifications
Display resolution: 0.1pW (display in W), 0.001dB (display in dBm)
Accuracy: The following is added to the accuracy of
each sensor.
(Within 24 hours after offset zero execu-
tion, unit: W)
20nW range ±(0.55% + 2000 digits)
200nW range ±(0.15% + 200 digits)
2μW to 200mW range ±(0% + 70 digits)
Display: LCD with three-level backlight
Wavelength display: 4 digits
Power display: 5½ digits (Unit: mW, μW, nW, dBm, dBr)
Bar graph display
Range switching: 8 ranges; auto, manual and remote
Sampling rate: 5 readings/sec or more
Wavelength sensitivity
correction:
Automatic correction of sensor wavelength
sensitivity by wavelength setting (in 1nm step)
Offset zero: Sensor offset stored in the memory for
automatic correction
Relative value display function: Ratio (display in W), dBr (display in dBm)
Analog output: Analog output according to the input signal *5
Output voltage: 0 to 2V, output resistance: 10Ω or less
Output connector: 2P mini-jack (3.5mm dia.)
USB interface: USB 2.0 Full-Speed compliant (connector
mini B/female)
Auto power off: Powers off approximately 30 minutes
after any key operation or remote opera-
tion is not performed. (Function can be
set ON or OFF.)
Backup function: Stores four setting conditions.
Smoothing function: Moving average from 2 to 100 times
Max value hold function: Holds the maximum measured value.
Calibration wavelength
selection function:
Available only with calibration wave-
length option(s) installed
Wavelength preset function *6
: Registers four wavelengths of which
sensitivity is corrected.
Other functions: CF calculation (sets one correction coefficient for
measured values.)
Display digit selection, key lock, and battery check
General Specifications
Operating environment: Ambient temperature: 0ºC to +40ºC
Relative humidity:80% or less, no condensation
Storage environment: Ambient temperature: -20ºC to +70ºC
Relative humidity:80% or less, no condensation
Warm-up time: 30 minutes or more (until the specified
accuracy is reached.)
Power supply
Battery drive: AA battery × 4 *7
Service life: 60 hours (with 1mW or less power, with
back light OFF, using the alkaline battery,
and at +23ºC±5ºC)
DC input: 9V 100mA or less
AC adapter: 100-240VAC
Line frequency: 50/60Hz
Power consumption: 100-120V: 5VA or less, 220-240V: 10VA or less
(when the supplied AC adapter is used.)
Dimensions: Approx. 80 (W) × 180 (H) × 40 (D) mm
Mass: 300g or less (excluding AA batteries)
Supplied Accessories
AC adapter (100-240VAC):		 A146001
Optional Accessories
USB cable	
(1m USB A/male-mini B/male):	 A112010
Analog output cable (1m):	 A01225
FC adapter (for 82321B/82322B/82323B/82324B):	 A08012
Power cable (UL/CSA):	 CC014001
Power cable (EN):	 CC014002
Power cable (CCC):	 CC014003
Wavelength Sensitivity Correction Option and Calibration Wavelength Option
Wavelength sensitivity correction option:
The wavelength sensitivity of each sensor is measured and corrected when
calibrating. (The 82311B/82321B of the standard specification is corrected
by using the typical value.)
Calibration wavelength option:
The calibration is performed at wavelengths other than the standard
specification. (Multiple wavelengths can be specified.)
*7: Use alkaline batteries only. Batteries are not included.
*5: The full-scale value varies depending on the sensor model, wavelength setting, cor-
rection value (CF), and range setting.
*6: This function is available when the software revision is B00 or later.
Optical power meter software revisions and applicable optical sensors
In addition to the optical sensors described in this brochure, discontinued
products 82311, 82312, 82313, 82314A, 82314W, 82321, 82322,
82323 and 82324A can be used.
The following table shows software revisions required for optical sensor operations.
Optical sensor Software revision
82311B D01 or later
82312B D01 or later
82313B D01 or later
82314B D01 or later
82314BW D01 or later
82321B D01 or later
82322B D01 or later
82323B D01 or later
82324B D01 or later
Optical sensor Software revision
82311 A00 or later
82312 A00 or later
82313 A00 or later
82314A B01 or later
82314W B01 or later
82321 A00 or later
82322 A00 or later
82323 A00 or later
82324A B01 or later
Thin-type sensor Cylindrical-type sensor
Option 82311B 82312B 82313B
Wavelength sensitivity correction OPT82311B+20 Standard specification Standard specification
Calibration
wavelength
405nm OPT82311B+21 Standard specification OPT82313B+21
650nm OPT82311B+22 − Standard specification
780nm Standard specification − OPT82313B+23
Option 82321B 82322B 82323B
Wavelength sensitivity correction OPT82321B+20 Standard specification Standard specification
Calibration
wavelength
405nm OPT82321B+21 Standard specification OPT82323B+21
650nm OPT82321B+22 − Standard specification
780nm Standard specification − OPT82323B+23
Option 82314B 82314BW 82324B
Wavelength sensitivity correction Standard specification Standard specification Standard specification
Calibration
wavelength
405nm Standard specification Standard specification Standard specification
650nm OPT82314B+22 OPT82314BW+22 OPT82324B+22
780nm OPT82314B+23 OPT82314BW+23 OPT82324B+23
Option Standard Opt.94 Opt.95 Opt.96
Applicable standard JIS CCC UL/CSA EN
Rated 125V/7A 250V/2.5A 125V/3A 250V/2.5A
If the software revision of your optical power meter is other than the above, the applicable
software to be installed can be downloaded from our website. For more information, please visit
our website.
USB interface
Analog output
DC input (9V)
Data acquisition and control with PC
Key lock function
Linear (W) and log (dBm) display function
5½ wide dynamic range display
Battery indicator
Wavelength sensitivity
correction function
Absolute value (dBr)
(Ratio) display function
Bar graph display
Setting wavelength display
Smoothing function
Backlight
1nm step setting
Three levels of
luminance
adjustment
Model 82311B (General-purpose) 82312B (Blue-violet) 82313B (High-power)
Wavelength range 390 to 1100nm 390 to 450nm 390 to 1100nm
Power range
Display in dBm -60 to +17dBm -50 to +20dBm −50 to +23dBm
Display in W 1nW to 50mW 10nW to 100mW 10nW to 200mW
Beam spot 3mm dia. or more 1mm dia. or more 0.1mm dia. or more
Light receiving element Si Photodiode
Light receiving area Approx. 9.5mm × 9.5mm Approx. 10mm × 10mm Approx. 8.5mm dia.
Effective light receiving area *1
Approx. 8.5mm x 8.5mm Approx. 6mm dia.
Calibration wavelength *2
780nm 405nm 650nm
Measurement accuracy (at 1mW input)
±2.5% (at calibration wavelength)
(±3.5%)*3
(400 to 1000nm) ±3.5% (390 to 450nm) ±3.5% (400 to 1000nm)
Wavelength sensitivity correction range 390 to 1100nm 390 to 450nm 390 to 1100nm
Shape Thin type
Separation from a sensor section *4
Impossible Possible Possible
Dimensions (width) × (height) × (thickness of
the light receiving section) mm
18×180×3.2 18×180×3.7 18×180×5
Model 82321B (General-purpose) 82322B (Blue-violet) 82323B (High-power)
Wavelength range 390 to 1100nm 390 to 450nm 390 to 1100nm
Power range
Display in dBm -60 to +17dBm -50 to +20dBm −50 to +23dBm
Display in W 1nW to 50mW 10nW to 100mW 10nW to 200mW
Beam spot 3mm dia. or more 1mm dia. or more 0.1mm dia. or more
Light receiving element Si Photodiode
Light receiving area Approx. 8.5mm dia.
Effective light receiving area *1
Approx. 6.5mm dia. Approx. 6mm dia.
Calibration wavelength *2
780nm 405nm 650nm
Measurement accuracy (at 1mW input)
±2.5% (at calibration wavelength)
(±3.5%)*3
(400 to 1000nm) ±3.5% (390 to 450nm) ±3.5% (400 to 1000nm)
Wavelength sensitivity correction range 390 to 1100nm 390 to 450nm 390 to 1100nm
Shape Cylindrical type
Dimensions (width) × (height) mm 38×40
Model 82314B/82314BW (Three-wavelength)
Wavelength range 390 to 900nm
Wavelength 405nm 650nm 780nm
Power range
Display in dBm −50 to +20dBm
Display in W 10nW to 100mW
Beam spot 1mm dia. or more / 2mm dia. or more 3mm dia. or more
Light receiving element Si Photodiode
Light receiving area Approx. 10mm × 10mm / Approx. 18mm × 18mm
Effective light receiving area *1
Approx. 9.5mm × 9.5mm / Approx. 15.5mm × 15.5mm
Calibration wavelength *2
Standard
OPT82314B+22/
OPT82314BW+22
OPT82314B+23/OPT82314BW+23
Measurement accuracy (at 1mW input)
±2.5% (at calibration wavelength)
±3.5% (390 to 900nm)
Wavelength sensitivity correction range 390 to 900nm
Shape Thin type
Separation from a sensor section*4
Possible
Dimensions (width) × (height) × (thickness of
the light receiving section) mm
18×180×3.7/35.1×197×3.7
Model 82324B (Three-wavelength)
Wavelength range 390 to 900nm
Wavelength 405nm 650nm 780nm
Power range
Display in dBm −50 to +20dBm
Display in W 10nW to 100mW
Beam spot 1mm dia. or more 3mm dia. or more
Light receiving element Si Photodiode
Light receiving area Approx. 8.5mm dia.
Effective light receiving area *1
Approx. 6.5mm dia.
Calibration wavelength *2
Standard OPT82324B+22 OPT82324B+23
Measurement accuracy (at 1mW input)
±2.5% (at calibration wavelength)
±3.5%(390 to 900nm)
Wavelength sensitivity correction range 390 to 900nm
Shape Cylindrical type
Dimensions (width) × (height) mm 38×40
2 3 4
200mW with high accuracy. These sensors have high linearity up to
200mW approximately even at beam spot of 0.1mm diameter.
200mW
● Low-priced and easy-to-use general-purpose
sensors
The 82311B and the 82321B are low-price general-purpose sen-
sors that can be used in a wide wavelength range from 390nm to
1100nm.
The calibration wavelength is 780nm and the correction value is
stored in the sensors. Sensitivity correction of other wavelengths
is also available by using the options.
● Both thin types and cylindrical types
Two shapes of sensors can be selected for each purpose. Thin
types of sensors are convenient for measuring optical power in
a limited space with a pickup installed, and cylindrical types of
sensors are used for measuring the output power from a fiber with
an optical bench.
● Blue-violet sensors to measure lasers of Blu-ray
Disc
To measure blue-violet lasers precisely, the 82312B and 82322B
blue-violet sensors have realized a maximally flat wavelength sen-
sitivity characteristic. This saves time in performing sensitivity
correction at each measurement and always offers high-accuracy
measurement results.
405nm (Blu-ray)
● Three-wavelength sensors to measure lasers
with different wavelengths
The 82314B, 82324B and 82314BW sensors are capable of mea-
suring all lasers of 405nm wavelength for Blu-ray Disc, 650 nm
wavelength for DVD and 780nm wavelength for CD. In the range
from 400 to 420nm wavelengths in particular, sensitivity cor-
rection is unnecessary because of the flat wavelength sensitivity
characteristic. In other wavelength ranges, the wavelength sensi-
tivity values stored in the sensor help easy operation.
405nm 650nm 780nm
● High-power sensors to measure high-power la-
sers for write
The power output of a laser disc for write such as CD-RW exceeds
100mW at the peak even with a pickup installed. The 82313B and
the 82323B are high-power sensors capable of measuring up to
Specifications
All accuracies are guaranteed for one year at a temperature of +23 ± 5°C and a relative humidity of 70% or less.
Sensor Specifications (Sold Separately)
*1: Relative sensitivity to the center is within the ±10% range.	 *2: Can be added by using options.	 *3: For the 82311B or 82321B, Option+20 is specified.
*4: The warranty does not include cut cables and/or damaged or degraded elements caused by connecting and disconnecting the sensor section.	
■ Nine Types of Optical Sensors to Meet Various Applications
The 8230 is an optical power meter optimal for building up automated
production lines of Blu-ray Disc, DVD, CD and other optical pickups.
It is equipped with a USB interface as standard, which allows easy
establishment of automated systems at a low price without adding any
external unit.
In addition, the latest USB driver is available from our website to make
your operation easier.
■ Ideal for Making Automated Systems
• Please read through the operation manual carefully before using the products.
• All specifications are subject to change without notice.
Instrument Specifications
Display resolution: 0.1pW (display in W), 0.001dB (display in dBm)
Accuracy: The following is added to the accuracy of
each sensor.
(Within 24 hours after offset zero execu-
tion, unit: W)
20nW range ±(0.55% + 2000 digits)
200nW range ±(0.15% + 200 digits)
2μW to 200mW range ±(0% + 70 digits)
Display: LCD with three-level backlight
Wavelength display: 4 digits
Power display: 5½ digits (Unit: mW, μW, nW, dBm, dBr)
Bar graph display
Range switching: 8 ranges; auto, manual and remote
Sampling rate: 5 readings/sec or more
Wavelength sensitivity
correction:
Automatic correction of sensor wavelength
sensitivity by wavelength setting (in 1nm step)
Offset zero: Sensor offset stored in the memory for
automatic correction
Relative value display function: Ratio (display in W), dBr (display in dBm)
Analog output: Analog output according to the input signal *5
Output voltage: 0 to 2V, output resistance: 10Ω or less
Output connector: 2P mini-jack (3.5mm dia.)
USB interface: USB 2.0 Full-Speed compliant (connector
mini B/female)
Auto power off: Powers off approximately 30 minutes
after any key operation or remote opera-
tion is not performed. (Function can be
set ON or OFF.)
Backup function: Stores four setting conditions.
Smoothing function: Moving average from 2 to 100 times
Max value hold function: Holds the maximum measured value.
Calibration wavelength
selection function:
Available only with calibration wave-
length option(s) installed
Wavelength preset function *6
: Registers four wavelengths of which
sensitivity is corrected.
Other functions: CF calculation (sets one correction coefficient for
measured values.)
Display digit selection, key lock, and battery check
General Specifications
Operating environment: Ambient temperature: 0ºC to +40ºC
Relative humidity:80% or less, no condensation
Storage environment: Ambient temperature: -20ºC to +70ºC
Relative humidity:80% or less, no condensation
Warm-up time: 30 minutes or more (until the specified
accuracy is reached.)
Power supply
Battery drive: AA battery × 4 *7
Service life: 60 hours (with 1mW or less power, with
back light OFF, using the alkaline battery,
and at +23ºC±5ºC)
DC input: 9V 100mA or less
AC adapter: 100-240VAC
Line frequency: 50/60Hz
Power consumption: 100-120V: 5VA or less, 220-240V: 10VA or less
(when the supplied AC adapter is used.)
Dimensions: Approx. 80 (W) × 180 (H) × 40 (D) mm
Mass: 300g or less (excluding AA batteries)
Supplied Accessories
AC adapter (100-240VAC):		 A146001
Optional Accessories
USB cable	
(1m USB A/male-mini B/male):	 A112010
Analog output cable (1m):	 A01225
FC adapter (for 82321B/82322B/82323B/82324B):	 A08012
Power cable (UL/CSA):	 CC014001
Power cable (EN):	 CC014002
Power cable (CCC):	 CC014003
Wavelength Sensitivity Correction Option and Calibration Wavelength Option
Wavelength sensitivity correction option:
The wavelength sensitivity of each sensor is measured and corrected when
calibrating. (The 82311B/82321B of the standard specification is corrected
by using the typical value.)
Calibration wavelength option:
The calibration is performed at wavelengths other than the standard
specification. (Multiple wavelengths can be specified.)
*7: Use alkaline batteries only. Batteries are not included.
*5: The full-scale value varies depending on the sensor model, wavelength setting, cor-
rection value (CF), and range setting.
*6: This function is available when the software revision is B00 or later.
Optical power meter software revisions and applicable optical sensors
In addition to the optical sensors described in this brochure, discontinued
products 82311, 82312, 82313, 82314A, 82314W, 82321, 82322,
82323 and 82324A can be used.
The following table shows software revisions required for optical sensor operations.
Optical sensor Software revision
82311B D01 or later
82312B D01 or later
82313B D01 or later
82314B D01 or later
82314BW D01 or later
82321B D01 or later
82322B D01 or later
82323B D01 or later
82324B D01 or later
Optical sensor Software revision
82311 A00 or later
82312 A00 or later
82313 A00 or later
82314A B01 or later
82314W B01 or later
82321 A00 or later
82322 A00 or later
82323 A00 or later
82324A B01 or later
Thin-type sensor Cylindrical-type sensor
Option 82311B 82312B 82313B
Wavelength sensitivity correction OPT82311B+20 Standard specification Standard specification
Calibration
wavelength
405nm OPT82311B+21 Standard specification OPT82313B+21
650nm OPT82311B+22 − Standard specification
780nm Standard specification − OPT82313B+23
Option 82321B 82322B 82323B
Wavelength sensitivity correction OPT82321B+20 Standard specification Standard specification
Calibration
wavelength
405nm OPT82321B+21 Standard specification OPT82323B+21
650nm OPT82321B+22 − Standard specification
780nm Standard specification − OPT82323B+23
Option 82314B 82314BW 82324B
Wavelength sensitivity correction Standard specification Standard specification Standard specification
Calibration
wavelength
405nm Standard specification Standard specification Standard specification
650nm OPT82314B+22 OPT82314BW+22 OPT82324B+22
780nm OPT82314B+23 OPT82314BW+23 OPT82324B+23
Option Standard Opt.94 Opt.95 Opt.96
Applicable standard JIS CCC UL/CSA EN
Rated 125V/7A 250V/2.5A 125V/3A 250V/2.5A
If the software revision of your optical power meter is other than the above, the applicable
software to be installed can be downloaded from our website. For more information, please visit
our website.
USB interface
Analog output
DC input (9V)
Data acquisition and control with PC
Key lock function
Linear (W) and log (dBm) display function
5½ wide dynamic range display
Battery indicator
Wavelength sensitivity
correction function
Absolute value (dBr)
(Ratio) display function
Bar graph display
Setting wavelength display
Smoothing function
Backlight
1nm step setting
Three levels of
luminance
adjustment
Model 82311B (General-purpose) 82312B (Blue-violet) 82313B (High-power)
Wavelength range 390 to 1100nm 390 to 450nm 390 to 1100nm
Power range
Display in dBm -60 to +17dBm -50 to +20dBm −50 to +23dBm
Display in W 1nW to 50mW 10nW to 100mW 10nW to 200mW
Beam spot 3mm dia. or more 1mm dia. or more 0.1mm dia. or more
Light receiving element Si Photodiode
Light receiving area Approx. 9.5mm × 9.5mm Approx. 10mm × 10mm Approx. 8.5mm dia.
Effective light receiving area *1
Approx. 8.5mm x 8.5mm Approx. 6mm dia.
Calibration wavelength *2
780nm 405nm 650nm
Measurement accuracy (at 1mW input)
±2.5% (at calibration wavelength)
(±3.5%)*3
(400 to 1000nm) ±3.5% (390 to 450nm) ±3.5% (400 to 1000nm)
Wavelength sensitivity correction range 390 to 1100nm 390 to 450nm 390 to 1100nm
Shape Thin type
Separation from a sensor section *4
Impossible Possible Possible
Dimensions (width) × (height) × (thickness of
the light receiving section) mm
18×180×3.2 18×180×3.7 18×180×5
Model 82321B (General-purpose) 82322B (Blue-violet) 82323B (High-power)
Wavelength range 390 to 1100nm 390 to 450nm 390 to 1100nm
Power range
Display in dBm -60 to +17dBm -50 to +20dBm −50 to +23dBm
Display in W 1nW to 50mW 10nW to 100mW 10nW to 200mW
Beam spot 3mm dia. or more 1mm dia. or more 0.1mm dia. or more
Light receiving element Si Photodiode
Light receiving area Approx. 8.5mm dia.
Effective light receiving area *1
Approx. 6.5mm dia. Approx. 6mm dia.
Calibration wavelength *2
780nm 405nm 650nm
Measurement accuracy (at 1mW input)
±2.5% (at calibration wavelength)
(±3.5%)*3
(400 to 1000nm) ±3.5% (390 to 450nm) ±3.5% (400 to 1000nm)
Wavelength sensitivity correction range 390 to 1100nm 390 to 450nm 390 to 1100nm
Shape Cylindrical type
Dimensions (width) × (height) mm 38×40
Model 82314B/82314BW (Three-wavelength)
Wavelength range 390 to 900nm
Wavelength 405nm 650nm 780nm
Power range
Display in dBm −50 to +20dBm
Display in W 10nW to 100mW
Beam spot 1mm dia. or more / 2mm dia. or more 3mm dia. or more
Light receiving element Si Photodiode
Light receiving area Approx. 10mm × 10mm / Approx. 18mm × 18mm
Effective light receiving area *1
Approx. 9.5mm × 9.5mm / Approx. 15.5mm × 15.5mm
Calibration wavelength *2
Standard
OPT82314B+22/
OPT82314BW+22
OPT82314B+23/OPT82314BW+23
Measurement accuracy (at 1mW input)
±2.5% (at calibration wavelength)
±3.5% (390 to 900nm)
Wavelength sensitivity correction range 390 to 900nm
Shape Thin type
Separation from a sensor section*4
Possible
Dimensions (width) × (height) × (thickness of
the light receiving section) mm
18×180×3.7/35.1×197×3.7
Model 82324B (Three-wavelength)
Wavelength range 390 to 900nm
Wavelength 405nm 650nm 780nm
Power range
Display in dBm −50 to +20dBm
Display in W 10nW to 100mW
Beam spot 1mm dia. or more 3mm dia. or more
Light receiving element Si Photodiode
Light receiving area Approx. 8.5mm dia.
Effective light receiving area *1
Approx. 6.5mm dia.
Calibration wavelength *2
Standard OPT82324B+22 OPT82324B+23
Measurement accuracy (at 1mW input)
±2.5% (at calibration wavelength)
±3.5%(390 to 900nm)
Wavelength sensitivity correction range 390 to 900nm
Shape Cylindrical type
Dimensions (width) × (height) mm 38×40
Head Office
Shoei Bldg, 3-6-12, Kyobashi, Chuou-ku,
Tokyo 104-0031, Japan
Phone: +81-3-6272-4433 Fax: +81-3-6272-4437
Higashimatsuyama Office (R&D Center)
77-1, Miyako Namegawa-machi, Hiki-gun,
Saitama 355-0812, Japan
Phone: +81-493-56-4433 Fax: +81-493-57-1092
E-mail : kcc@adcmt.com URL : http://www.adcmt-e.com
© 2011 ADC CORPORATION Printed in Japan 8230A-NP2E Oct. '11 AO
5
Sensor Characteristics (Typical Values)
General-purpose sensor
-60
120
100
80
60
40
20
-40 -20 0 20 40 60
deg
82311B Incident angle dependence
(780nm)
P polarization
S polarization
Circular polarization
P polarization
S polarization
Circular polarization
0
50
40
30
20
10
0
10 20 30 40 50 60
deg
82311B Reflectance (780nm)
1
2
0
-2
-4
-6
-8
-10
10 100
Incident Power [mW]
82311B/82321B Power linearity
(780nm)
Beamφ0.1
Beamφ0.7
Beamφ3
Linearuty(%)
Reflectance(%)
380
140
120
100
80
60
40
20
0
580 780 980
wavelength [nm]
82311B/82321B Wavelength sensitivity
Sensitivity(%)
Sensitivity(%)
-60
120
100
80
60
40
20
-40 -20 0 20 40 60
deg
82312B/82322B Incident angle dependence
(405nm)
P polarization
S polarization
Circular polarization
P polarization
S polarization
Circular polarization
0
50
40
30
20
10
0
10 20 30 40 50 60
deg
82312B/82322B Reflectance
(405nm)
1
2
0
-2
-4
-6
-8
-10
10 100
Incident Power [mW]
82312B/82322B Power linearity
(405nm)
Beamφ0.1
Beamφ0.7
Linearuty(%)
Reflectance(%)
400
101
100
99
98
97
95
0
405 410 415 420
wavelength [nm]
82312B/82322B Wavelength sensitivity
Sensitivity(%)
Sensitivity(%)
-60
120
100
80
60
40
20
-40 -20 0 20 40 60
deg
82313B/82323B Incident angle dependence
(780nm)
P polarization
S polarization
Circular polarization
0
50
40
30
20
10
0
10 20 30 40 50 60
deg
82313B/82323B Reflectance
(780nm)
P polarization
S polarization
Circular polarization
1
2
0
-2
-4
-6
-8
-10
10 100 1000
Incident Power [mW]
82313B/82323B Power linearity Beamφ0.1
Beamφ0.7
Linearuty(%)
Reflectance(%)
380
140
120
100
80
60
40
20
0
580 780 980 1180
wavelength [nm]
82313B/82323B Wavelength sensitivity
Sensitivity(%)
Sensitivity(%)
Blue-violet sensor
High-power sensor
Sensor Characteristics (Typical Values)
Three-wavelength sensor
0
120
100
80
60
40
20
10 20 30 40 50 60
deg
82314B/82314BW/32324B
Incident angle dependence (405nm)
0
30
40
50
20
10
0
10 20 30 40 50 60
deg
82314B/82314BW/32324B
Reflectance (405nm)
400
105
104
103
102
101
100
99
98
97
96
95
405 410 420
415
82314B/82314BW/32324B
Wavelength sensitivity (405nm)
Reflectance(%)
wavelength [nm]
Sensitivity(%)
Sensitivity(%)
390
140
120
100
80
60
40
20
0
490 590 890
690 790
82314B/82314BW/32324B
Wavelength sensitivity (all levels)
wavelength [nm]
Sensitivity(%)
P polarization
S polarization
Circular polarization
P polarization
S polarization
Circular polarization
Dimensional Drawing
10
18
180
11
18
180
99
∗
5
受光素子面までの距離0.5mm
3.2
保護硝子面までの距離0.8mm
受光素子面までの距離1.8mm
3.2
Distance to the cover glass surface: 0.8mm
Distance to the light receiving element surface: 1.8mm
(8.5)
10
18
180
99
72.5
82311B
82312B/82313B
82314B
∗: Fixing screw hole
M3 (5mm max.)
∗:Fixing screw hole
M3 (5mm max.)
∗:Fixing screw hole
M3 (6mm max.)
3.7
Distance to the cover glass surface: 0.1mm
Distance to the light receiving element surface: 1.4mm
Distance to the light
receiving element surface: 2.15mm
Distance to the cover
glass surface: 0.65mm
M33×1.5
φ 38
φ14
17.55
197
35.1
∗
∗
82314BW 82324B
(8.5)
76
1500
72.5
40
35
28
5
11
18
180
82313B
82312B
82314B
5
Distance to the light receiving
element surface: 0.5mm
11
18
3.7
Distance to the cover glass surface: 0.1mm
Distance to the light receiving element surface: 1.4mm
11
18
3.7
Distance to the cover glass
surface: 0.3mm
Distance to the light receiving
element surface: 1.4mm
11
18
82312B/3B
82314B
8230
Optical Power Meter
Perfect for use in R&D and production lines of next-
generation optical discs and for evaluation of blue-
violet and high-power lasers
l	 A wide selection of optical sensors for different use
l	Three-wavelength optical sensors covering 405/650/780nm
l	Blue-violet optical sensors for 405nm laser measurement
l	High-power optical sensors for high-power laser measurement
l	Low-price general-purpose optical sensors
l		Both thin type and cylindrical type available
l	 Optical power calibration wavelengths: 405/650/780nm
l	 5½-digit display and 0.001dB resolution
l	 USB interface
http://www.adcmt-e.com
82311B
82321B
82312B
82322B
82313B
82323B
82314B
82324B
82314BW
405
nm
405
nm
650
nm
650
nm
780
nm
780
nm
Head Office
Shoei Bldg, 3-6-12, Kyobashi, Chuou-ku,
Tokyo 104-0031, Japan
Phone: +81-3-6272-4433 Fax: +81-3-6272-4437
Higashimatsuyama Office (R&D Center)
77-1, Miyako Namegawa-machi, Hiki-gun,
Saitama 355-0812, Japan
Phone: +81-493-56-4433 Fax: +81-493-57-1092
E-mail : kcc@adcmt.com URL : http://www.adcmt-e.com
© 2011 ADC CORPORATION Printed in Japan 8230A-NP2E Oct. '11 AO
5
Sensor Characteristics (Typical Values)
General-purpose sensor
-60
120
100
80
60
40
20
-40 -20 0 20 40 60
deg
82311B Incident angle dependence
(780nm)
P polarization
S polarization
Circular polarization
P polarization
S polarization
Circular polarization
0
50
40
30
20
10
0
10 20 30 40 50 60
deg
82311B Reflectance (780nm)
1
2
0
-2
-4
-6
-8
-10
10 100
Incident Power [mW]
82311B/82321B Power linearity
(780nm)
Beamφ0.1
Beamφ0.7
Beamφ3
Linearuty(%)
Reflectance(%)
380
140
120
100
80
60
40
20
0
580 780 980
wavelength [nm]
82311B/82321B Wavelength sensitivity
Sensitivity(%)
Sensitivity(%)
-60
120
100
80
60
40
20
-40 -20 0 20 40 60
deg
82312B/82322B Incident angle dependence
(405nm)
P polarization
S polarization
Circular polarization
P polarization
S polarization
Circular polarization
0
50
40
30
20
10
0
10 20 30 40 50 60
deg
82312B/82322B Reflectance
(405nm)
1
2
0
-2
-4
-6
-8
-10
10 100
Incident Power [mW]
82312B/82322B Power linearity
(405nm)
Beamφ0.1
Beamφ0.7
Linearuty(%)
Reflectance(%)
400
101
100
99
98
97
95
0
405 410 415 420
wavelength [nm]
82312B/82322B Wavelength sensitivity
Sensitivity(%)
Sensitivity(%)
-60
120
100
80
60
40
20
-40 -20 0 20 40 60
deg
82313B/82323B Incident angle dependence
(780nm)
P polarization
S polarization
Circular polarization
0
50
40
30
20
10
0
10 20 30 40 50 60
deg
82313B/82323B Reflectance
(780nm)
P polarization
S polarization
Circular polarization
1
2
0
-2
-4
-6
-8
-10
10 100 1000
Incident Power [mW]
82313B/82323B Power linearity Beamφ0.1
Beamφ0.7
Linearuty(%)
Reflectance(%)
380
140
120
100
80
60
40
20
0
580 780 980 1180
wavelength [nm]
82313B/82323B Wavelength sensitivity
Sensitivity(%)
Sensitivity(%)
Blue-violet sensor
High-power sensor
Sensor Characteristics (Typical Values)
Three-wavelength sensor
0
120
100
80
60
40
20
10 20 30 40 50 60
deg
82314B/82314BW/32324B
Incident angle dependence (405nm)
0
30
40
50
20
10
0
10 20 30 40 50 60
deg
82314B/82314BW/32324B
Reflectance (405nm)
400
105
104
103
102
101
100
99
98
97
96
95
405 410 420
415
82314B/82314BW/32324B
Wavelength sensitivity (405nm)
Reflectance(%)
wavelength [nm]
Sensitivity(%)
Sensitivity(%)
390
140
120
100
80
60
40
20
0
490 590 890
690 790
82314B/82314BW/32324B
Wavelength sensitivity (all levels)
wavelength [nm]
Sensitivity(%)
P polarization
S polarization
Circular polarization
P polarization
S polarization
Circular polarization
Dimensional Drawing
10
18
180
11
18
180
99
∗
5
受光素子面までの距離0.5mm
3.2
保護硝子面までの距離0.8mm
受光素子面までの距離1.8mm
3.2
Distance to the cover glass surface: 0.8mm
Distance to the light receiving element surface: 1.8mm
(8.5)
10
18
180
99
72.5
82311B
82312B/82313B
82314B
∗: Fixing screw hole
M3 (5mm max.)
∗:Fixing screw hole
M3 (5mm max.)
∗:Fixing screw hole
M3 (6mm max.)
3.7
Distance to the cover glass surface: 0.1mm
Distance to the light receiving element surface: 1.4mm
Distance to the light
receiving element surface: 2.15mm
Distance to the cover
glass surface: 0.65mm
M33×1.5
φ 38
φ14
17.55
197
35.1
∗
∗
82314BW 82324B
(8.5)
76
1500
72.5
40
35
28
5
11
18
180
82313B
82312B
82314B
5
Distance to the light receiving
element surface: 0.5mm
11
18
3.7
Distance to the cover glass surface: 0.1mm
Distance to the light receiving element surface: 1.4mm
11
18
3.7
Distance to the cover glass
surface: 0.3mm
Distance to the light receiving
element surface: 1.4mm
11
18
82312B/3B
82314B
8230
Optical Power Meter
Perfect for use in R&D and production lines of next-
generation optical discs and for evaluation of blue-
violet and high-power lasers
l	 A wide selection of optical sensors for different use
l	Three-wavelength optical sensors covering 405/650/780nm
l	Blue-violet optical sensors for 405nm laser measurement
l	High-power optical sensors for high-power laser measurement
l	Low-price general-purpose optical sensors
l		Both thin type and cylindrical type available
l	 Optical power calibration wavelengths: 405/650/780nm
l	 5½-digit display and 0.001dB resolution
l	 USB interface
http://www.adcmt-e.com
82311B
82321B
82312B
82322B
82313B
82323B
82314B
82324B
82314BW
405
nm
405
nm
650
nm
650
nm
780
nm
780
nm
https://www.n-denkei.com/singapore/inquiry/

More Related Content

Similar to Adcmt 8230 e-optical_power_meter_denkei

jual total station sokkia cx
jual total station sokkia cxjual total station sokkia cx
jual total station sokkia cxRegi Bungsu
 
Jual Total Ststion Sokkia CX 101 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 101   Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 101   Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 101 Murah Call. Somantri 087778355373ALAMSURVEY
 
Jual Total Ststion Sokkia CX 103 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 103  Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 103  Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 103 Murah Call. Somantri 087778355373ALAMSURVEY
 
Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163alam survey
 
Jual Total Ststion Sokkia CX 102 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 102   Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 102   Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 102 Murah Call. Somantri 087778355373ALAMSURVEY
 
Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373ALAMSURVEY
 
Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163alam survey
 
medigatemed.com-Ophthalmology Equipment.pdf
medigatemed.com-Ophthalmology Equipment.pdfmedigatemed.com-Ophthalmology Equipment.pdf
medigatemed.com-Ophthalmology Equipment.pdfjacob walls
 
Micro e systems_mercury1000_datasheet
Micro e systems_mercury1000_datasheetMicro e systems_mercury1000_datasheet
Micro e systems_mercury1000_datasheetElectromate
 
MARGA SETIA JUAL TOTAL STATION SOKKIA CX-105C INFO 082217294199
MARGA SETIA JUAL TOTAL STATION SOKKIA CX-105C INFO 082217294199MARGA SETIA JUAL TOTAL STATION SOKKIA CX-105C INFO 082217294199
MARGA SETIA JUAL TOTAL STATION SOKKIA CX-105C INFO 082217294199asfirman
 
sokkia_cx_series_brochure
sokkia_cx_series_brochuresokkia_cx_series_brochure
sokkia_cx_series_brochureHemlata Garg
 
Jasa Kalibrasi, Rental dan Jual Total Station Sokkia IM-52 Call/ wa 082119953499
Jasa Kalibrasi, Rental dan Jual Total Station Sokkia IM-52 Call/ wa 082119953499Jasa Kalibrasi, Rental dan Jual Total Station Sokkia IM-52 Call/ wa 082119953499
Jasa Kalibrasi, Rental dan Jual Total Station Sokkia IM-52 Call/ wa 082119953499Budi anto
 
Brosur Total Station Topcon gm 50 gm-52 gm-55
Brosur Total Station Topcon gm 50 gm-52 gm-55Brosur Total Station Topcon gm 50 gm-52 gm-55
Brosur Total Station Topcon gm 50 gm-52 gm-55Rega Surveyor
 
SALE##TOTAL STATION TOPCON ES105/ES103 HUB 087876262648
SALE##TOTAL STATION TOPCON ES105/ES103 HUB 087876262648SALE##TOTAL STATION TOPCON ES105/ES103 HUB 087876262648
SALE##TOTAL STATION TOPCON ES105/ES103 HUB 087876262648andy jaya
 
topcon Es 105 pdf
topcon Es 105 pdftopcon Es 105 pdf
topcon Es 105 pdfandy jaya
 
Micro e systems_mercury1500p_datasheet
Micro e systems_mercury1500p_datasheetMicro e systems_mercury1500p_datasheet
Micro e systems_mercury1500p_datasheetElectromate
 

Similar to Adcmt 8230 e-optical_power_meter_denkei (20)

jual total station sokkia cx
jual total station sokkia cxjual total station sokkia cx
jual total station sokkia cx
 
Jual Total Ststion Sokkia CX 101 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 101   Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 101   Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 101 Murah Call. Somantri 087778355373
 
Jual Total Ststion Sokkia CX 103 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 103  Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 103  Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 103 Murah Call. Somantri 087778355373
 
Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163
 
Jual Total Ststion Sokkia CX 102 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 102   Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 102   Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 102 Murah Call. Somantri 087778355373
 
Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373
 
Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163
 
Cx brochure
Cx brochureCx brochure
Cx brochure
 
Es e 105
Es e 105Es e 105
Es e 105
 
medigatemed.com-Ophthalmology Equipment.pdf
medigatemed.com-Ophthalmology Equipment.pdfmedigatemed.com-Ophthalmology Equipment.pdf
medigatemed.com-Ophthalmology Equipment.pdf
 
Micro e systems_mercury1000_datasheet
Micro e systems_mercury1000_datasheetMicro e systems_mercury1000_datasheet
Micro e systems_mercury1000_datasheet
 
MARGA SETIA JUAL TOTAL STATION SOKKIA CX-105C INFO 082217294199
MARGA SETIA JUAL TOTAL STATION SOKKIA CX-105C INFO 082217294199MARGA SETIA JUAL TOTAL STATION SOKKIA CX-105C INFO 082217294199
MARGA SETIA JUAL TOTAL STATION SOKKIA CX-105C INFO 082217294199
 
sokkia_cx_series_brochure
sokkia_cx_series_brochuresokkia_cx_series_brochure
sokkia_cx_series_brochure
 
Jasa Kalibrasi, Rental dan Jual Total Station Sokkia IM-52 Call/ wa 082119953499
Jasa Kalibrasi, Rental dan Jual Total Station Sokkia IM-52 Call/ wa 082119953499Jasa Kalibrasi, Rental dan Jual Total Station Sokkia IM-52 Call/ wa 082119953499
Jasa Kalibrasi, Rental dan Jual Total Station Sokkia IM-52 Call/ wa 082119953499
 
Brosur Total Station Topcon gm 50 gm-52 gm-55
Brosur Total Station Topcon gm 50 gm-52 gm-55Brosur Total Station Topcon gm 50 gm-52 gm-55
Brosur Total Station Topcon gm 50 gm-52 gm-55
 
cEs e 105
cEs e 105cEs e 105
cEs e 105
 
SALE##TOTAL STATION TOPCON ES105/ES103 HUB 087876262648
SALE##TOTAL STATION TOPCON ES105/ES103 HUB 087876262648SALE##TOTAL STATION TOPCON ES105/ES103 HUB 087876262648
SALE##TOTAL STATION TOPCON ES105/ES103 HUB 087876262648
 
Es e 105
Es e 105Es e 105
Es e 105
 
topcon Es 105 pdf
topcon Es 105 pdftopcon Es 105 pdf
topcon Es 105 pdf
 
Micro e systems_mercury1500p_datasheet
Micro e systems_mercury1500p_datasheetMicro e systems_mercury1500p_datasheet
Micro e systems_mercury1500p_datasheet
 

More from NIHON DENKEI SINGAPORE

Quantum Computer - Low noise signal processing solution
Quantum Computer - Low noise signal processing solutionQuantum Computer - Low noise signal processing solution
Quantum Computer - Low noise signal processing solutionNIHON DENKEI SINGAPORE
 
MTI Japan Magnetic Field Measurement Instruments
MTI Japan Magnetic Field Measurement InstrumentsMTI Japan Magnetic Field Measurement Instruments
MTI Japan Magnetic Field Measurement InstrumentsNIHON DENKEI SINGAPORE
 
catalog-en-20190708_safety_training_machine.pdf
catalog-en-20190708_safety_training_machine.pdfcatalog-en-20190708_safety_training_machine.pdf
catalog-en-20190708_safety_training_machine.pdfNIHON DENKEI SINGAPORE
 
Ono sokki ds3000 Data Station DS-3000 series Sound and Vibration Real-time...
Ono sokki ds3000  Data Station  DS-3000 series  Sound and Vibration Real-time...Ono sokki ds3000  Data Station  DS-3000 series  Sound and Vibration Real-time...
Ono sokki ds3000 Data Station DS-3000 series Sound and Vibration Real-time...NIHON DENKEI SINGAPORE
 
HIOKI Current Series sensors probes_e1-1_zb
HIOKI Current  Series sensors probes_e1-1_zbHIOKI Current  Series sensors probes_e1-1_zb
HIOKI Current Series sensors probes_e1-1_zbNIHON DENKEI SINGAPORE
 
Hioki Field measuring instruments 2022 catalogue
Hioki Field measuring instruments 2022 catalogueHioki Field measuring instruments 2022 catalogue
Hioki Field measuring instruments 2022 catalogueNIHON DENKEI SINGAPORE
 
Hioki Electrical measuring instruments 2022 catalogue
Hioki Electrical measuring instruments 2022 catalogueHioki Electrical measuring instruments 2022 catalogue
Hioki Electrical measuring instruments 2022 catalogueNIHON DENKEI SINGAPORE
 
KG Electronic load DC power supply Ripple and Noise meter
KG Electronic load DC power supply Ripple and Noise meterKG Electronic load DC power supply Ripple and Noise meter
KG Electronic load DC power supply Ripple and Noise meterNIHON DENKEI SINGAPORE
 
ONO SOKKI Elevator Speedometer EC-2100
ONO SOKKI Elevator Speedometer  EC-2100ONO SOKKI Elevator Speedometer  EC-2100
ONO SOKKI Elevator Speedometer EC-2100NIHON DENKEI SINGAPORE
 
KIKUSUI PBZ Series Intelligent Bi-Polar Power Supplies
KIKUSUI PBZ Series Intelligent Bi-Polar Power Supplies KIKUSUI PBZ Series Intelligent Bi-Polar Power Supplies
KIKUSUI PBZ Series Intelligent Bi-Polar Power Supplies NIHON DENKEI SINGAPORE
 
Rion product for_the_automotive_industry
Rion product for_the_automotive_industry Rion product for_the_automotive_industry
Rion product for_the_automotive_industry NIHON DENKEI SINGAPORE
 
ADCMT DC Voltage Current Source/Monitor Catalog 6253 DENKEI
ADCMT DC Voltage Current Source/Monitor  Catalog 6253  DENKEIADCMT DC Voltage Current Source/Monitor  Catalog 6253  DENKEI
ADCMT DC Voltage Current Source/Monitor Catalog 6253 DENKEINIHON DENKEI SINGAPORE
 
RIGOL Programmable linear DC power supply DP800 Series
RIGOL  Programmable linear DC power supply DP800 SeriesRIGOL  Programmable linear DC power supply DP800 Series
RIGOL Programmable linear DC power supply DP800 SeriesNIHON DENKEI SINGAPORE
 
Aikoh General Catalogue in Japanese catj201907
Aikoh General Catalogue in Japanese  catj201907Aikoh General Catalogue in Japanese  catj201907
Aikoh General Catalogue in Japanese catj201907NIHON DENKEI SINGAPORE
 

More from NIHON DENKEI SINGAPORE (20)

Quantum Computer - Low noise signal processing solution
Quantum Computer - Low noise signal processing solutionQuantum Computer - Low noise signal processing solution
Quantum Computer - Low noise signal processing solution
 
MTI Japan Magnetic Field Measurement Instruments
MTI Japan Magnetic Field Measurement InstrumentsMTI Japan Magnetic Field Measurement Instruments
MTI Japan Magnetic Field Measurement Instruments
 
catalog-en-20190708_safety_training_machine.pdf
catalog-en-20190708_safety_training_machine.pdfcatalog-en-20190708_safety_training_machine.pdf
catalog-en-20190708_safety_training_machine.pdf
 
Ono sokki ds3000 Data Station DS-3000 series Sound and Vibration Real-time...
Ono sokki ds3000  Data Station  DS-3000 series  Sound and Vibration Real-time...Ono sokki ds3000  Data Station  DS-3000 series  Sound and Vibration Real-time...
Ono sokki ds3000 Data Station DS-3000 series Sound and Vibration Real-time...
 
Hioki data logger selection
Hioki data logger selectionHioki data logger selection
Hioki data logger selection
 
HIOKI Current Series sensors probes_e1-1_zb
HIOKI Current  Series sensors probes_e1-1_zbHIOKI Current  Series sensors probes_e1-1_zb
HIOKI Current Series sensors probes_e1-1_zb
 
Hioki Field measuring instruments 2022 catalogue
Hioki Field measuring instruments 2022 catalogueHioki Field measuring instruments 2022 catalogue
Hioki Field measuring instruments 2022 catalogue
 
Hioki Electrical measuring instruments 2022 catalogue
Hioki Electrical measuring instruments 2022 catalogueHioki Electrical measuring instruments 2022 catalogue
Hioki Electrical measuring instruments 2022 catalogue
 
9322 Hioki Differential Probe
9322 Hioki Differential Probe9322 Hioki Differential Probe
9322 Hioki Differential Probe
 
KG Electronic load DC power supply Ripple and Noise meter
KG Electronic load DC power supply Ripple and Noise meterKG Electronic load DC power supply Ripple and Noise meter
KG Electronic load DC power supply Ripple and Noise meter
 
HIOKI Power Analyzer Pw8001
HIOKI Power Analyzer  Pw8001 HIOKI Power Analyzer  Pw8001
HIOKI Power Analyzer Pw8001
 
ONO SOKKI Elevator Speedometer EC-2100
ONO SOKKI Elevator Speedometer  EC-2100ONO SOKKI Elevator Speedometer  EC-2100
ONO SOKKI Elevator Speedometer EC-2100
 
KIKUSUI PBZ Series Intelligent Bi-Polar Power Supplies
KIKUSUI PBZ Series Intelligent Bi-Polar Power Supplies KIKUSUI PBZ Series Intelligent Bi-Polar Power Supplies
KIKUSUI PBZ Series Intelligent Bi-Polar Power Supplies
 
Rion product for_the_automotive_industry
Rion product for_the_automotive_industry Rion product for_the_automotive_industry
Rion product for_the_automotive_industry
 
HIOKI BYPASS DIODE TESTER FT4310
HIOKI BYPASS DIODE TESTER FT4310HIOKI BYPASS DIODE TESTER FT4310
HIOKI BYPASS DIODE TESTER FT4310
 
TEAC Load cell catalog (JAPAN)
TEAC Load cell catalog  (JAPAN) TEAC Load cell catalog  (JAPAN)
TEAC Load cell catalog (JAPAN)
 
ADCMT DC Voltage Current Source/Monitor Catalog 6253 DENKEI
ADCMT DC Voltage Current Source/Monitor  Catalog 6253  DENKEIADCMT DC Voltage Current Source/Monitor  Catalog 6253  DENKEI
ADCMT DC Voltage Current Source/Monitor Catalog 6253 DENKEI
 
RIGOL Programmable linear DC power supply DP800 Series
RIGOL  Programmable linear DC power supply DP800 SeriesRIGOL  Programmable linear DC power supply DP800 Series
RIGOL Programmable linear DC power supply DP800 Series
 
Rz catalogue cn AIKOH 推拉力计
Rz catalogue cn AIKOH 推拉力计Rz catalogue cn AIKOH 推拉力计
Rz catalogue cn AIKOH 推拉力计
 
Aikoh General Catalogue in Japanese catj201907
Aikoh General Catalogue in Japanese  catj201907Aikoh General Catalogue in Japanese  catj201907
Aikoh General Catalogue in Japanese catj201907
 

Recently uploaded

"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii SoldatenkoFwdays
 
Unleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubUnleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubKalema Edgar
 
AI as an Interface for Commercial Buildings
AI as an Interface for Commercial BuildingsAI as an Interface for Commercial Buildings
AI as an Interface for Commercial BuildingsMemoori
 
Install Stable Diffusion in windows machine
Install Stable Diffusion in windows machineInstall Stable Diffusion in windows machine
Install Stable Diffusion in windows machinePadma Pradeep
 
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks..."LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...Fwdays
 
Unraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfUnraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfAlex Barbosa Coqueiro
 
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024BookNet Canada
 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsMark Billinghurst
 
Artificial intelligence in cctv survelliance.pptx
Artificial intelligence in cctv survelliance.pptxArtificial intelligence in cctv survelliance.pptx
Artificial intelligence in cctv survelliance.pptxhariprasad279825
 
Connect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationConnect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationSlibray Presentation
 
Beyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry InnovationBeyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry InnovationSafe Software
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfAddepto
 
Dev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebDev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebUiPathCommunity
 
WordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your BrandWordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your Brandgvaughan
 
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 3652toLead Limited
 
Powerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time ClashPowerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time Clashcharlottematthew16
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitecturePixlogix Infotech
 
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...shyamraj55
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Patryk Bandurski
 

Recently uploaded (20)

"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko
 
Unleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding ClubUnleash Your Potential - Namagunga Girls Coding Club
Unleash Your Potential - Namagunga Girls Coding Club
 
Hot Sexy call girls in Panjabi Bagh 🔝 9953056974 🔝 Delhi escort Service
Hot Sexy call girls in Panjabi Bagh 🔝 9953056974 🔝 Delhi escort ServiceHot Sexy call girls in Panjabi Bagh 🔝 9953056974 🔝 Delhi escort Service
Hot Sexy call girls in Panjabi Bagh 🔝 9953056974 🔝 Delhi escort Service
 
AI as an Interface for Commercial Buildings
AI as an Interface for Commercial BuildingsAI as an Interface for Commercial Buildings
AI as an Interface for Commercial Buildings
 
Install Stable Diffusion in windows machine
Install Stable Diffusion in windows machineInstall Stable Diffusion in windows machine
Install Stable Diffusion in windows machine
 
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks..."LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
 
Unraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfUnraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdf
 
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR Systems
 
Artificial intelligence in cctv survelliance.pptx
Artificial intelligence in cctv survelliance.pptxArtificial intelligence in cctv survelliance.pptx
Artificial intelligence in cctv survelliance.pptx
 
Connect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationConnect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck Presentation
 
Beyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry InnovationBeyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdf
 
Dev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebDev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio Web
 
WordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your BrandWordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your Brand
 
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
 
Powerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time ClashPowerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time Clash
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC Architecture
 
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
 

Adcmt 8230 e-optical_power_meter_denkei

  • 1. Head Office Shoei Bldg, 3-6-12, Kyobashi, Chuou-ku, Tokyo 104-0031, Japan Phone: +81-3-6272-4433 Fax: +81-3-6272-4437 Higashimatsuyama Office (R&D Center) 77-1, Miyako Namegawa-machi, Hiki-gun, Saitama 355-0812, Japan Phone: +81-493-56-4433 Fax: +81-493-57-1092 E-mail : kcc@adcmt.com URL : http://www.adcmt-e.com © 2011 ADC CORPORATION Printed in Japan 8230A-NP2E Oct. '11 AO 5 Sensor Characteristics (Typical Values) General-purpose sensor -60 120 100 80 60 40 20 -40 -20 0 20 40 60 deg 82311B Incident angle dependence (780nm) P polarization S polarization Circular polarization P polarization S polarization Circular polarization 0 50 40 30 20 10 0 10 20 30 40 50 60 deg 82311B Reflectance (780nm) 1 2 0 -2 -4 -6 -8 -10 10 100 Incident Power [mW] 82311B/82321B Power linearity (780nm) Beamφ0.1 Beamφ0.7 Beamφ3 Linearuty(%) Reflectance(%) 380 140 120 100 80 60 40 20 0 580 780 980 wavelength [nm] 82311B/82321B Wavelength sensitivity Sensitivity(%) Sensitivity(%) -60 120 100 80 60 40 20 -40 -20 0 20 40 60 deg 82312B/82322B Incident angle dependence (405nm) P polarization S polarization Circular polarization P polarization S polarization Circular polarization 0 50 40 30 20 10 0 10 20 30 40 50 60 deg 82312B/82322B Reflectance (405nm) 1 2 0 -2 -4 -6 -8 -10 10 100 Incident Power [mW] 82312B/82322B Power linearity (405nm) Beamφ0.1 Beamφ0.7 Linearuty(%) Reflectance(%) 400 101 100 99 98 97 95 0 405 410 415 420 wavelength [nm] 82312B/82322B Wavelength sensitivity Sensitivity(%) Sensitivity(%) -60 120 100 80 60 40 20 -40 -20 0 20 40 60 deg 82313B/82323B Incident angle dependence (780nm) P polarization S polarization Circular polarization 0 50 40 30 20 10 0 10 20 30 40 50 60 deg 82313B/82323B Reflectance (780nm) P polarization S polarization Circular polarization 1 2 0 -2 -4 -6 -8 -10 10 100 1000 Incident Power [mW] 82313B/82323B Power linearity Beamφ0.1 Beamφ0.7 Linearuty(%) Reflectance(%) 380 140 120 100 80 60 40 20 0 580 780 980 1180 wavelength [nm] 82313B/82323B Wavelength sensitivity Sensitivity(%) Sensitivity(%) Blue-violet sensor High-power sensor Sensor Characteristics (Typical Values) Three-wavelength sensor 0 120 100 80 60 40 20 10 20 30 40 50 60 deg 82314B/82314BW/32324B Incident angle dependence (405nm) 0 30 40 50 20 10 0 10 20 30 40 50 60 deg 82314B/82314BW/32324B Reflectance (405nm) 400 105 104 103 102 101 100 99 98 97 96 95 405 410 420 415 82314B/82314BW/32324B Wavelength sensitivity (405nm) Reflectance(%) wavelength [nm] Sensitivity(%) Sensitivity(%) 390 140 120 100 80 60 40 20 0 490 590 890 690 790 82314B/82314BW/32324B Wavelength sensitivity (all levels) wavelength [nm] Sensitivity(%) P polarization S polarization Circular polarization P polarization S polarization Circular polarization Dimensional Drawing 10 18 180 11 18 180 99 ∗ 5 受光素子面までの距離0.5mm 3.2 保護硝子面までの距離0.8mm 受光素子面までの距離1.8mm 3.2 Distance to the cover glass surface: 0.8mm Distance to the light receiving element surface: 1.8mm (8.5) 10 18 180 99 72.5 82311B 82312B/82313B 82314B ∗: Fixing screw hole M3 (5mm max.) ∗:Fixing screw hole M3 (5mm max.) ∗:Fixing screw hole M3 (6mm max.) 3.7 Distance to the cover glass surface: 0.1mm Distance to the light receiving element surface: 1.4mm Distance to the light receiving element surface: 2.15mm Distance to the cover glass surface: 0.65mm M33×1.5 φ 38 φ14 17.55 197 35.1 ∗ ∗ 82314BW 82324B (8.5) 76 1500 72.5 40 35 28 5 11 18 180 82313B 82312B 82314B 5 Distance to the light receiving element surface: 0.5mm 11 18 3.7 Distance to the cover glass surface: 0.1mm Distance to the light receiving element surface: 1.4mm 11 18 3.7 Distance to the cover glass surface: 0.3mm Distance to the light receiving element surface: 1.4mm 11 18 82312B/3B 82314B 8230 Optical Power Meter Perfect for use in R&D and production lines of next- generation optical discs and for evaluation of blue- violet and high-power lasers l A wide selection of optical sensors for different use l Three-wavelength optical sensors covering 405/650/780nm l Blue-violet optical sensors for 405nm laser measurement l High-power optical sensors for high-power laser measurement l Low-price general-purpose optical sensors l Both thin type and cylindrical type available l Optical power calibration wavelengths: 405/650/780nm l 5½-digit display and 0.001dB resolution l USB interface http://www.adcmt-e.com 82311B 82321B 82312B 82322B 82313B 82323B 82314B 82324B 82314BW 405 nm 405 nm 650 nm 650 nm 780 nm 780 nm
  • 2. 2 3 4 200mW with high accuracy. These sensors have high linearity up to 200mW approximately even at beam spot of 0.1mm diameter. 200mW ● Low-priced and easy-to-use general-purpose sensors The 82311B and the 82321B are low-price general-purpose sen- sors that can be used in a wide wavelength range from 390nm to 1100nm. The calibration wavelength is 780nm and the correction value is stored in the sensors. Sensitivity correction of other wavelengths is also available by using the options. ● Both thin types and cylindrical types Two shapes of sensors can be selected for each purpose. Thin types of sensors are convenient for measuring optical power in a limited space with a pickup installed, and cylindrical types of sensors are used for measuring the output power from a fiber with an optical bench. ● Blue-violet sensors to measure lasers of Blu-ray Disc To measure blue-violet lasers precisely, the 82312B and 82322B blue-violet sensors have realized a maximally flat wavelength sen- sitivity characteristic. This saves time in performing sensitivity correction at each measurement and always offers high-accuracy measurement results. 405nm (Blu-ray) ● Three-wavelength sensors to measure lasers with different wavelengths The 82314B, 82324B and 82314BW sensors are capable of mea- suring all lasers of 405nm wavelength for Blu-ray Disc, 650 nm wavelength for DVD and 780nm wavelength for CD. In the range from 400 to 420nm wavelengths in particular, sensitivity cor- rection is unnecessary because of the flat wavelength sensitivity characteristic. In other wavelength ranges, the wavelength sensi- tivity values stored in the sensor help easy operation. 405nm 650nm 780nm ● High-power sensors to measure high-power la- sers for write The power output of a laser disc for write such as CD-RW exceeds 100mW at the peak even with a pickup installed. The 82313B and the 82323B are high-power sensors capable of measuring up to Specifications All accuracies are guaranteed for one year at a temperature of +23 ± 5°C and a relative humidity of 70% or less. Sensor Specifications (Sold Separately) *1: Relative sensitivity to the center is within the ±10% range. *2: Can be added by using options. *3: For the 82311B or 82321B, Option+20 is specified. *4: The warranty does not include cut cables and/or damaged or degraded elements caused by connecting and disconnecting the sensor section. ■ Nine Types of Optical Sensors to Meet Various Applications The 8230 is an optical power meter optimal for building up automated production lines of Blu-ray Disc, DVD, CD and other optical pickups. It is equipped with a USB interface as standard, which allows easy establishment of automated systems at a low price without adding any external unit. In addition, the latest USB driver is available from our website to make your operation easier. ■ Ideal for Making Automated Systems • Please read through the operation manual carefully before using the products. • All specifications are subject to change without notice. Instrument Specifications Display resolution: 0.1pW (display in W), 0.001dB (display in dBm) Accuracy: The following is added to the accuracy of each sensor. (Within 24 hours after offset zero execu- tion, unit: W) 20nW range ±(0.55% + 2000 digits) 200nW range ±(0.15% + 200 digits) 2μW to 200mW range ±(0% + 70 digits) Display: LCD with three-level backlight Wavelength display: 4 digits Power display: 5½ digits (Unit: mW, μW, nW, dBm, dBr) Bar graph display Range switching: 8 ranges; auto, manual and remote Sampling rate: 5 readings/sec or more Wavelength sensitivity correction: Automatic correction of sensor wavelength sensitivity by wavelength setting (in 1nm step) Offset zero: Sensor offset stored in the memory for automatic correction Relative value display function: Ratio (display in W), dBr (display in dBm) Analog output: Analog output according to the input signal *5 Output voltage: 0 to 2V, output resistance: 10Ω or less Output connector: 2P mini-jack (3.5mm dia.) USB interface: USB 2.0 Full-Speed compliant (connector mini B/female) Auto power off: Powers off approximately 30 minutes after any key operation or remote opera- tion is not performed. (Function can be set ON or OFF.) Backup function: Stores four setting conditions. Smoothing function: Moving average from 2 to 100 times Max value hold function: Holds the maximum measured value. Calibration wavelength selection function: Available only with calibration wave- length option(s) installed Wavelength preset function *6 : Registers four wavelengths of which sensitivity is corrected. Other functions: CF calculation (sets one correction coefficient for measured values.) Display digit selection, key lock, and battery check General Specifications Operating environment: Ambient temperature: 0ºC to +40ºC Relative humidity:80% or less, no condensation Storage environment: Ambient temperature: -20ºC to +70ºC Relative humidity:80% or less, no condensation Warm-up time: 30 minutes or more (until the specified accuracy is reached.) Power supply Battery drive: AA battery × 4 *7 Service life: 60 hours (with 1mW or less power, with back light OFF, using the alkaline battery, and at +23ºC±5ºC) DC input: 9V 100mA or less AC adapter: 100-240VAC Line frequency: 50/60Hz Power consumption: 100-120V: 5VA or less, 220-240V: 10VA or less (when the supplied AC adapter is used.) Dimensions: Approx. 80 (W) × 180 (H) × 40 (D) mm Mass: 300g or less (excluding AA batteries) Supplied Accessories AC adapter (100-240VAC): A146001 Optional Accessories USB cable (1m USB A/male-mini B/male): A112010 Analog output cable (1m): A01225 FC adapter (for 82321B/82322B/82323B/82324B): A08012 Power cable (UL/CSA): CC014001 Power cable (EN): CC014002 Power cable (CCC): CC014003 Wavelength Sensitivity Correction Option and Calibration Wavelength Option Wavelength sensitivity correction option: The wavelength sensitivity of each sensor is measured and corrected when calibrating. (The 82311B/82321B of the standard specification is corrected by using the typical value.) Calibration wavelength option: The calibration is performed at wavelengths other than the standard specification. (Multiple wavelengths can be specified.) *7: Use alkaline batteries only. Batteries are not included. *5: The full-scale value varies depending on the sensor model, wavelength setting, cor- rection value (CF), and range setting. *6: This function is available when the software revision is B00 or later. Optical power meter software revisions and applicable optical sensors In addition to the optical sensors described in this brochure, discontinued products 82311, 82312, 82313, 82314A, 82314W, 82321, 82322, 82323 and 82324A can be used. The following table shows software revisions required for optical sensor operations. Optical sensor Software revision 82311B D01 or later 82312B D01 or later 82313B D01 or later 82314B D01 or later 82314BW D01 or later 82321B D01 or later 82322B D01 or later 82323B D01 or later 82324B D01 or later Optical sensor Software revision 82311 A00 or later 82312 A00 or later 82313 A00 or later 82314A B01 or later 82314W B01 or later 82321 A00 or later 82322 A00 or later 82323 A00 or later 82324A B01 or later Thin-type sensor Cylindrical-type sensor Option 82311B 82312B 82313B Wavelength sensitivity correction OPT82311B+20 Standard specification Standard specification Calibration wavelength 405nm OPT82311B+21 Standard specification OPT82313B+21 650nm OPT82311B+22 − Standard specification 780nm Standard specification − OPT82313B+23 Option 82321B 82322B 82323B Wavelength sensitivity correction OPT82321B+20 Standard specification Standard specification Calibration wavelength 405nm OPT82321B+21 Standard specification OPT82323B+21 650nm OPT82321B+22 − Standard specification 780nm Standard specification − OPT82323B+23 Option 82314B 82314BW 82324B Wavelength sensitivity correction Standard specification Standard specification Standard specification Calibration wavelength 405nm Standard specification Standard specification Standard specification 650nm OPT82314B+22 OPT82314BW+22 OPT82324B+22 780nm OPT82314B+23 OPT82314BW+23 OPT82324B+23 Option Standard Opt.94 Opt.95 Opt.96 Applicable standard JIS CCC UL/CSA EN Rated 125V/7A 250V/2.5A 125V/3A 250V/2.5A If the software revision of your optical power meter is other than the above, the applicable software to be installed can be downloaded from our website. For more information, please visit our website. USB interface Analog output DC input (9V) Data acquisition and control with PC Key lock function Linear (W) and log (dBm) display function 5½ wide dynamic range display Battery indicator Wavelength sensitivity correction function Absolute value (dBr) (Ratio) display function Bar graph display Setting wavelength display Smoothing function Backlight 1nm step setting Three levels of luminance adjustment Model 82311B (General-purpose) 82312B (Blue-violet) 82313B (High-power) Wavelength range 390 to 1100nm 390 to 450nm 390 to 1100nm Power range Display in dBm -60 to +17dBm -50 to +20dBm −50 to +23dBm Display in W 1nW to 50mW 10nW to 100mW 10nW to 200mW Beam spot 3mm dia. or more 1mm dia. or more 0.1mm dia. or more Light receiving element Si Photodiode Light receiving area Approx. 9.5mm × 9.5mm Approx. 10mm × 10mm Approx. 8.5mm dia. Effective light receiving area *1 Approx. 8.5mm x 8.5mm Approx. 6mm dia. Calibration wavelength *2 780nm 405nm 650nm Measurement accuracy (at 1mW input) ±2.5% (at calibration wavelength) (±3.5%)*3 (400 to 1000nm) ±3.5% (390 to 450nm) ±3.5% (400 to 1000nm) Wavelength sensitivity correction range 390 to 1100nm 390 to 450nm 390 to 1100nm Shape Thin type Separation from a sensor section *4 Impossible Possible Possible Dimensions (width) × (height) × (thickness of the light receiving section) mm 18×180×3.2 18×180×3.7 18×180×5 Model 82321B (General-purpose) 82322B (Blue-violet) 82323B (High-power) Wavelength range 390 to 1100nm 390 to 450nm 390 to 1100nm Power range Display in dBm -60 to +17dBm -50 to +20dBm −50 to +23dBm Display in W 1nW to 50mW 10nW to 100mW 10nW to 200mW Beam spot 3mm dia. or more 1mm dia. or more 0.1mm dia. or more Light receiving element Si Photodiode Light receiving area Approx. 8.5mm dia. Effective light receiving area *1 Approx. 6.5mm dia. Approx. 6mm dia. Calibration wavelength *2 780nm 405nm 650nm Measurement accuracy (at 1mW input) ±2.5% (at calibration wavelength) (±3.5%)*3 (400 to 1000nm) ±3.5% (390 to 450nm) ±3.5% (400 to 1000nm) Wavelength sensitivity correction range 390 to 1100nm 390 to 450nm 390 to 1100nm Shape Cylindrical type Dimensions (width) × (height) mm 38×40 Model 82314B/82314BW (Three-wavelength) Wavelength range 390 to 900nm Wavelength 405nm 650nm 780nm Power range Display in dBm −50 to +20dBm Display in W 10nW to 100mW Beam spot 1mm dia. or more / 2mm dia. or more 3mm dia. or more Light receiving element Si Photodiode Light receiving area Approx. 10mm × 10mm / Approx. 18mm × 18mm Effective light receiving area *1 Approx. 9.5mm × 9.5mm / Approx. 15.5mm × 15.5mm Calibration wavelength *2 Standard OPT82314B+22/ OPT82314BW+22 OPT82314B+23/OPT82314BW+23 Measurement accuracy (at 1mW input) ±2.5% (at calibration wavelength) ±3.5% (390 to 900nm) Wavelength sensitivity correction range 390 to 900nm Shape Thin type Separation from a sensor section*4 Possible Dimensions (width) × (height) × (thickness of the light receiving section) mm 18×180×3.7/35.1×197×3.7 Model 82324B (Three-wavelength) Wavelength range 390 to 900nm Wavelength 405nm 650nm 780nm Power range Display in dBm −50 to +20dBm Display in W 10nW to 100mW Beam spot 1mm dia. or more 3mm dia. or more Light receiving element Si Photodiode Light receiving area Approx. 8.5mm dia. Effective light receiving area *1 Approx. 6.5mm dia. Calibration wavelength *2 Standard OPT82324B+22 OPT82324B+23 Measurement accuracy (at 1mW input) ±2.5% (at calibration wavelength) ±3.5%(390 to 900nm) Wavelength sensitivity correction range 390 to 900nm Shape Cylindrical type Dimensions (width) × (height) mm 38×40
  • 3. 2 3 4 200mW with high accuracy. These sensors have high linearity up to 200mW approximately even at beam spot of 0.1mm diameter. 200mW ● Low-priced and easy-to-use general-purpose sensors The 82311B and the 82321B are low-price general-purpose sen- sors that can be used in a wide wavelength range from 390nm to 1100nm. The calibration wavelength is 780nm and the correction value is stored in the sensors. Sensitivity correction of other wavelengths is also available by using the options. ● Both thin types and cylindrical types Two shapes of sensors can be selected for each purpose. Thin types of sensors are convenient for measuring optical power in a limited space with a pickup installed, and cylindrical types of sensors are used for measuring the output power from a fiber with an optical bench. ● Blue-violet sensors to measure lasers of Blu-ray Disc To measure blue-violet lasers precisely, the 82312B and 82322B blue-violet sensors have realized a maximally flat wavelength sen- sitivity characteristic. This saves time in performing sensitivity correction at each measurement and always offers high-accuracy measurement results. 405nm (Blu-ray) ● Three-wavelength sensors to measure lasers with different wavelengths The 82314B, 82324B and 82314BW sensors are capable of mea- suring all lasers of 405nm wavelength for Blu-ray Disc, 650 nm wavelength for DVD and 780nm wavelength for CD. In the range from 400 to 420nm wavelengths in particular, sensitivity cor- rection is unnecessary because of the flat wavelength sensitivity characteristic. In other wavelength ranges, the wavelength sensi- tivity values stored in the sensor help easy operation. 405nm 650nm 780nm ● High-power sensors to measure high-power la- sers for write The power output of a laser disc for write such as CD-RW exceeds 100mW at the peak even with a pickup installed. The 82313B and the 82323B are high-power sensors capable of measuring up to Specifications All accuracies are guaranteed for one year at a temperature of +23 ± 5°C and a relative humidity of 70% or less. Sensor Specifications (Sold Separately) *1: Relative sensitivity to the center is within the ±10% range. *2: Can be added by using options. *3: For the 82311B or 82321B, Option+20 is specified. *4: The warranty does not include cut cables and/or damaged or degraded elements caused by connecting and disconnecting the sensor section. ■ Nine Types of Optical Sensors to Meet Various Applications The 8230 is an optical power meter optimal for building up automated production lines of Blu-ray Disc, DVD, CD and other optical pickups. It is equipped with a USB interface as standard, which allows easy establishment of automated systems at a low price without adding any external unit. In addition, the latest USB driver is available from our website to make your operation easier. ■ Ideal for Making Automated Systems • Please read through the operation manual carefully before using the products. • All specifications are subject to change without notice. Instrument Specifications Display resolution: 0.1pW (display in W), 0.001dB (display in dBm) Accuracy: The following is added to the accuracy of each sensor. (Within 24 hours after offset zero execu- tion, unit: W) 20nW range ±(0.55% + 2000 digits) 200nW range ±(0.15% + 200 digits) 2μW to 200mW range ±(0% + 70 digits) Display: LCD with three-level backlight Wavelength display: 4 digits Power display: 5½ digits (Unit: mW, μW, nW, dBm, dBr) Bar graph display Range switching: 8 ranges; auto, manual and remote Sampling rate: 5 readings/sec or more Wavelength sensitivity correction: Automatic correction of sensor wavelength sensitivity by wavelength setting (in 1nm step) Offset zero: Sensor offset stored in the memory for automatic correction Relative value display function: Ratio (display in W), dBr (display in dBm) Analog output: Analog output according to the input signal *5 Output voltage: 0 to 2V, output resistance: 10Ω or less Output connector: 2P mini-jack (3.5mm dia.) USB interface: USB 2.0 Full-Speed compliant (connector mini B/female) Auto power off: Powers off approximately 30 minutes after any key operation or remote opera- tion is not performed. (Function can be set ON or OFF.) Backup function: Stores four setting conditions. Smoothing function: Moving average from 2 to 100 times Max value hold function: Holds the maximum measured value. Calibration wavelength selection function: Available only with calibration wave- length option(s) installed Wavelength preset function *6 : Registers four wavelengths of which sensitivity is corrected. Other functions: CF calculation (sets one correction coefficient for measured values.) Display digit selection, key lock, and battery check General Specifications Operating environment: Ambient temperature: 0ºC to +40ºC Relative humidity:80% or less, no condensation Storage environment: Ambient temperature: -20ºC to +70ºC Relative humidity:80% or less, no condensation Warm-up time: 30 minutes or more (until the specified accuracy is reached.) Power supply Battery drive: AA battery × 4 *7 Service life: 60 hours (with 1mW or less power, with back light OFF, using the alkaline battery, and at +23ºC±5ºC) DC input: 9V 100mA or less AC adapter: 100-240VAC Line frequency: 50/60Hz Power consumption: 100-120V: 5VA or less, 220-240V: 10VA or less (when the supplied AC adapter is used.) Dimensions: Approx. 80 (W) × 180 (H) × 40 (D) mm Mass: 300g or less (excluding AA batteries) Supplied Accessories AC adapter (100-240VAC): A146001 Optional Accessories USB cable (1m USB A/male-mini B/male): A112010 Analog output cable (1m): A01225 FC adapter (for 82321B/82322B/82323B/82324B): A08012 Power cable (UL/CSA): CC014001 Power cable (EN): CC014002 Power cable (CCC): CC014003 Wavelength Sensitivity Correction Option and Calibration Wavelength Option Wavelength sensitivity correction option: The wavelength sensitivity of each sensor is measured and corrected when calibrating. (The 82311B/82321B of the standard specification is corrected by using the typical value.) Calibration wavelength option: The calibration is performed at wavelengths other than the standard specification. (Multiple wavelengths can be specified.) *7: Use alkaline batteries only. Batteries are not included. *5: The full-scale value varies depending on the sensor model, wavelength setting, cor- rection value (CF), and range setting. *6: This function is available when the software revision is B00 or later. Optical power meter software revisions and applicable optical sensors In addition to the optical sensors described in this brochure, discontinued products 82311, 82312, 82313, 82314A, 82314W, 82321, 82322, 82323 and 82324A can be used. The following table shows software revisions required for optical sensor operations. Optical sensor Software revision 82311B D01 or later 82312B D01 or later 82313B D01 or later 82314B D01 or later 82314BW D01 or later 82321B D01 or later 82322B D01 or later 82323B D01 or later 82324B D01 or later Optical sensor Software revision 82311 A00 or later 82312 A00 or later 82313 A00 or later 82314A B01 or later 82314W B01 or later 82321 A00 or later 82322 A00 or later 82323 A00 or later 82324A B01 or later Thin-type sensor Cylindrical-type sensor Option 82311B 82312B 82313B Wavelength sensitivity correction OPT82311B+20 Standard specification Standard specification Calibration wavelength 405nm OPT82311B+21 Standard specification OPT82313B+21 650nm OPT82311B+22 − Standard specification 780nm Standard specification − OPT82313B+23 Option 82321B 82322B 82323B Wavelength sensitivity correction OPT82321B+20 Standard specification Standard specification Calibration wavelength 405nm OPT82321B+21 Standard specification OPT82323B+21 650nm OPT82321B+22 − Standard specification 780nm Standard specification − OPT82323B+23 Option 82314B 82314BW 82324B Wavelength sensitivity correction Standard specification Standard specification Standard specification Calibration wavelength 405nm Standard specification Standard specification Standard specification 650nm OPT82314B+22 OPT82314BW+22 OPT82324B+22 780nm OPT82314B+23 OPT82314BW+23 OPT82324B+23 Option Standard Opt.94 Opt.95 Opt.96 Applicable standard JIS CCC UL/CSA EN Rated 125V/7A 250V/2.5A 125V/3A 250V/2.5A If the software revision of your optical power meter is other than the above, the applicable software to be installed can be downloaded from our website. For more information, please visit our website. USB interface Analog output DC input (9V) Data acquisition and control with PC Key lock function Linear (W) and log (dBm) display function 5½ wide dynamic range display Battery indicator Wavelength sensitivity correction function Absolute value (dBr) (Ratio) display function Bar graph display Setting wavelength display Smoothing function Backlight 1nm step setting Three levels of luminance adjustment Model 82311B (General-purpose) 82312B (Blue-violet) 82313B (High-power) Wavelength range 390 to 1100nm 390 to 450nm 390 to 1100nm Power range Display in dBm -60 to +17dBm -50 to +20dBm −50 to +23dBm Display in W 1nW to 50mW 10nW to 100mW 10nW to 200mW Beam spot 3mm dia. or more 1mm dia. or more 0.1mm dia. or more Light receiving element Si Photodiode Light receiving area Approx. 9.5mm × 9.5mm Approx. 10mm × 10mm Approx. 8.5mm dia. Effective light receiving area *1 Approx. 8.5mm x 8.5mm Approx. 6mm dia. Calibration wavelength *2 780nm 405nm 650nm Measurement accuracy (at 1mW input) ±2.5% (at calibration wavelength) (±3.5%)*3 (400 to 1000nm) ±3.5% (390 to 450nm) ±3.5% (400 to 1000nm) Wavelength sensitivity correction range 390 to 1100nm 390 to 450nm 390 to 1100nm Shape Thin type Separation from a sensor section *4 Impossible Possible Possible Dimensions (width) × (height) × (thickness of the light receiving section) mm 18×180×3.2 18×180×3.7 18×180×5 Model 82321B (General-purpose) 82322B (Blue-violet) 82323B (High-power) Wavelength range 390 to 1100nm 390 to 450nm 390 to 1100nm Power range Display in dBm -60 to +17dBm -50 to +20dBm −50 to +23dBm Display in W 1nW to 50mW 10nW to 100mW 10nW to 200mW Beam spot 3mm dia. or more 1mm dia. or more 0.1mm dia. or more Light receiving element Si Photodiode Light receiving area Approx. 8.5mm dia. Effective light receiving area *1 Approx. 6.5mm dia. Approx. 6mm dia. Calibration wavelength *2 780nm 405nm 650nm Measurement accuracy (at 1mW input) ±2.5% (at calibration wavelength) (±3.5%)*3 (400 to 1000nm) ±3.5% (390 to 450nm) ±3.5% (400 to 1000nm) Wavelength sensitivity correction range 390 to 1100nm 390 to 450nm 390 to 1100nm Shape Cylindrical type Dimensions (width) × (height) mm 38×40 Model 82314B/82314BW (Three-wavelength) Wavelength range 390 to 900nm Wavelength 405nm 650nm 780nm Power range Display in dBm −50 to +20dBm Display in W 10nW to 100mW Beam spot 1mm dia. or more / 2mm dia. or more 3mm dia. or more Light receiving element Si Photodiode Light receiving area Approx. 10mm × 10mm / Approx. 18mm × 18mm Effective light receiving area *1 Approx. 9.5mm × 9.5mm / Approx. 15.5mm × 15.5mm Calibration wavelength *2 Standard OPT82314B+22/ OPT82314BW+22 OPT82314B+23/OPT82314BW+23 Measurement accuracy (at 1mW input) ±2.5% (at calibration wavelength) ±3.5% (390 to 900nm) Wavelength sensitivity correction range 390 to 900nm Shape Thin type Separation from a sensor section*4 Possible Dimensions (width) × (height) × (thickness of the light receiving section) mm 18×180×3.7/35.1×197×3.7 Model 82324B (Three-wavelength) Wavelength range 390 to 900nm Wavelength 405nm 650nm 780nm Power range Display in dBm −50 to +20dBm Display in W 10nW to 100mW Beam spot 1mm dia. or more 3mm dia. or more Light receiving element Si Photodiode Light receiving area Approx. 8.5mm dia. Effective light receiving area *1 Approx. 6.5mm dia. Calibration wavelength *2 Standard OPT82324B+22 OPT82324B+23 Measurement accuracy (at 1mW input) ±2.5% (at calibration wavelength) ±3.5%(390 to 900nm) Wavelength sensitivity correction range 390 to 900nm Shape Cylindrical type Dimensions (width) × (height) mm 38×40
  • 4. 2 3 4 200mW with high accuracy. These sensors have high linearity up to 200mW approximately even at beam spot of 0.1mm diameter. 200mW ● Low-priced and easy-to-use general-purpose sensors The 82311B and the 82321B are low-price general-purpose sen- sors that can be used in a wide wavelength range from 390nm to 1100nm. The calibration wavelength is 780nm and the correction value is stored in the sensors. Sensitivity correction of other wavelengths is also available by using the options. ● Both thin types and cylindrical types Two shapes of sensors can be selected for each purpose. Thin types of sensors are convenient for measuring optical power in a limited space with a pickup installed, and cylindrical types of sensors are used for measuring the output power from a fiber with an optical bench. ● Blue-violet sensors to measure lasers of Blu-ray Disc To measure blue-violet lasers precisely, the 82312B and 82322B blue-violet sensors have realized a maximally flat wavelength sen- sitivity characteristic. This saves time in performing sensitivity correction at each measurement and always offers high-accuracy measurement results. 405nm (Blu-ray) ● Three-wavelength sensors to measure lasers with different wavelengths The 82314B, 82324B and 82314BW sensors are capable of mea- suring all lasers of 405nm wavelength for Blu-ray Disc, 650 nm wavelength for DVD and 780nm wavelength for CD. In the range from 400 to 420nm wavelengths in particular, sensitivity cor- rection is unnecessary because of the flat wavelength sensitivity characteristic. In other wavelength ranges, the wavelength sensi- tivity values stored in the sensor help easy operation. 405nm 650nm 780nm ● High-power sensors to measure high-power la- sers for write The power output of a laser disc for write such as CD-RW exceeds 100mW at the peak even with a pickup installed. The 82313B and the 82323B are high-power sensors capable of measuring up to Specifications All accuracies are guaranteed for one year at a temperature of +23 ± 5°C and a relative humidity of 70% or less. Sensor Specifications (Sold Separately) *1: Relative sensitivity to the center is within the ±10% range. *2: Can be added by using options. *3: For the 82311B or 82321B, Option+20 is specified. *4: The warranty does not include cut cables and/or damaged or degraded elements caused by connecting and disconnecting the sensor section. ■ Nine Types of Optical Sensors to Meet Various Applications The 8230 is an optical power meter optimal for building up automated production lines of Blu-ray Disc, DVD, CD and other optical pickups. It is equipped with a USB interface as standard, which allows easy establishment of automated systems at a low price without adding any external unit. In addition, the latest USB driver is available from our website to make your operation easier. ■ Ideal for Making Automated Systems • Please read through the operation manual carefully before using the products. • All specifications are subject to change without notice. Instrument Specifications Display resolution: 0.1pW (display in W), 0.001dB (display in dBm) Accuracy: The following is added to the accuracy of each sensor. (Within 24 hours after offset zero execu- tion, unit: W) 20nW range ±(0.55% + 2000 digits) 200nW range ±(0.15% + 200 digits) 2μW to 200mW range ±(0% + 70 digits) Display: LCD with three-level backlight Wavelength display: 4 digits Power display: 5½ digits (Unit: mW, μW, nW, dBm, dBr) Bar graph display Range switching: 8 ranges; auto, manual and remote Sampling rate: 5 readings/sec or more Wavelength sensitivity correction: Automatic correction of sensor wavelength sensitivity by wavelength setting (in 1nm step) Offset zero: Sensor offset stored in the memory for automatic correction Relative value display function: Ratio (display in W), dBr (display in dBm) Analog output: Analog output according to the input signal *5 Output voltage: 0 to 2V, output resistance: 10Ω or less Output connector: 2P mini-jack (3.5mm dia.) USB interface: USB 2.0 Full-Speed compliant (connector mini B/female) Auto power off: Powers off approximately 30 minutes after any key operation or remote opera- tion is not performed. (Function can be set ON or OFF.) Backup function: Stores four setting conditions. Smoothing function: Moving average from 2 to 100 times Max value hold function: Holds the maximum measured value. Calibration wavelength selection function: Available only with calibration wave- length option(s) installed Wavelength preset function *6 : Registers four wavelengths of which sensitivity is corrected. Other functions: CF calculation (sets one correction coefficient for measured values.) Display digit selection, key lock, and battery check General Specifications Operating environment: Ambient temperature: 0ºC to +40ºC Relative humidity:80% or less, no condensation Storage environment: Ambient temperature: -20ºC to +70ºC Relative humidity:80% or less, no condensation Warm-up time: 30 minutes or more (until the specified accuracy is reached.) Power supply Battery drive: AA battery × 4 *7 Service life: 60 hours (with 1mW or less power, with back light OFF, using the alkaline battery, and at +23ºC±5ºC) DC input: 9V 100mA or less AC adapter: 100-240VAC Line frequency: 50/60Hz Power consumption: 100-120V: 5VA or less, 220-240V: 10VA or less (when the supplied AC adapter is used.) Dimensions: Approx. 80 (W) × 180 (H) × 40 (D) mm Mass: 300g or less (excluding AA batteries) Supplied Accessories AC adapter (100-240VAC): A146001 Optional Accessories USB cable (1m USB A/male-mini B/male): A112010 Analog output cable (1m): A01225 FC adapter (for 82321B/82322B/82323B/82324B): A08012 Power cable (UL/CSA): CC014001 Power cable (EN): CC014002 Power cable (CCC): CC014003 Wavelength Sensitivity Correction Option and Calibration Wavelength Option Wavelength sensitivity correction option: The wavelength sensitivity of each sensor is measured and corrected when calibrating. (The 82311B/82321B of the standard specification is corrected by using the typical value.) Calibration wavelength option: The calibration is performed at wavelengths other than the standard specification. (Multiple wavelengths can be specified.) *7: Use alkaline batteries only. Batteries are not included. *5: The full-scale value varies depending on the sensor model, wavelength setting, cor- rection value (CF), and range setting. *6: This function is available when the software revision is B00 or later. Optical power meter software revisions and applicable optical sensors In addition to the optical sensors described in this brochure, discontinued products 82311, 82312, 82313, 82314A, 82314W, 82321, 82322, 82323 and 82324A can be used. The following table shows software revisions required for optical sensor operations. Optical sensor Software revision 82311B D01 or later 82312B D01 or later 82313B D01 or later 82314B D01 or later 82314BW D01 or later 82321B D01 or later 82322B D01 or later 82323B D01 or later 82324B D01 or later Optical sensor Software revision 82311 A00 or later 82312 A00 or later 82313 A00 or later 82314A B01 or later 82314W B01 or later 82321 A00 or later 82322 A00 or later 82323 A00 or later 82324A B01 or later Thin-type sensor Cylindrical-type sensor Option 82311B 82312B 82313B Wavelength sensitivity correction OPT82311B+20 Standard specification Standard specification Calibration wavelength 405nm OPT82311B+21 Standard specification OPT82313B+21 650nm OPT82311B+22 − Standard specification 780nm Standard specification − OPT82313B+23 Option 82321B 82322B 82323B Wavelength sensitivity correction OPT82321B+20 Standard specification Standard specification Calibration wavelength 405nm OPT82321B+21 Standard specification OPT82323B+21 650nm OPT82321B+22 − Standard specification 780nm Standard specification − OPT82323B+23 Option 82314B 82314BW 82324B Wavelength sensitivity correction Standard specification Standard specification Standard specification Calibration wavelength 405nm Standard specification Standard specification Standard specification 650nm OPT82314B+22 OPT82314BW+22 OPT82324B+22 780nm OPT82314B+23 OPT82314BW+23 OPT82324B+23 Option Standard Opt.94 Opt.95 Opt.96 Applicable standard JIS CCC UL/CSA EN Rated 125V/7A 250V/2.5A 125V/3A 250V/2.5A If the software revision of your optical power meter is other than the above, the applicable software to be installed can be downloaded from our website. For more information, please visit our website. USB interface Analog output DC input (9V) Data acquisition and control with PC Key lock function Linear (W) and log (dBm) display function 5½ wide dynamic range display Battery indicator Wavelength sensitivity correction function Absolute value (dBr) (Ratio) display function Bar graph display Setting wavelength display Smoothing function Backlight 1nm step setting Three levels of luminance adjustment Model 82311B (General-purpose) 82312B (Blue-violet) 82313B (High-power) Wavelength range 390 to 1100nm 390 to 450nm 390 to 1100nm Power range Display in dBm -60 to +17dBm -50 to +20dBm −50 to +23dBm Display in W 1nW to 50mW 10nW to 100mW 10nW to 200mW Beam spot 3mm dia. or more 1mm dia. or more 0.1mm dia. or more Light receiving element Si Photodiode Light receiving area Approx. 9.5mm × 9.5mm Approx. 10mm × 10mm Approx. 8.5mm dia. Effective light receiving area *1 Approx. 8.5mm x 8.5mm Approx. 6mm dia. Calibration wavelength *2 780nm 405nm 650nm Measurement accuracy (at 1mW input) ±2.5% (at calibration wavelength) (±3.5%)*3 (400 to 1000nm) ±3.5% (390 to 450nm) ±3.5% (400 to 1000nm) Wavelength sensitivity correction range 390 to 1100nm 390 to 450nm 390 to 1100nm Shape Thin type Separation from a sensor section *4 Impossible Possible Possible Dimensions (width) × (height) × (thickness of the light receiving section) mm 18×180×3.2 18×180×3.7 18×180×5 Model 82321B (General-purpose) 82322B (Blue-violet) 82323B (High-power) Wavelength range 390 to 1100nm 390 to 450nm 390 to 1100nm Power range Display in dBm -60 to +17dBm -50 to +20dBm −50 to +23dBm Display in W 1nW to 50mW 10nW to 100mW 10nW to 200mW Beam spot 3mm dia. or more 1mm dia. or more 0.1mm dia. or more Light receiving element Si Photodiode Light receiving area Approx. 8.5mm dia. Effective light receiving area *1 Approx. 6.5mm dia. Approx. 6mm dia. Calibration wavelength *2 780nm 405nm 650nm Measurement accuracy (at 1mW input) ±2.5% (at calibration wavelength) (±3.5%)*3 (400 to 1000nm) ±3.5% (390 to 450nm) ±3.5% (400 to 1000nm) Wavelength sensitivity correction range 390 to 1100nm 390 to 450nm 390 to 1100nm Shape Cylindrical type Dimensions (width) × (height) mm 38×40 Model 82314B/82314BW (Three-wavelength) Wavelength range 390 to 900nm Wavelength 405nm 650nm 780nm Power range Display in dBm −50 to +20dBm Display in W 10nW to 100mW Beam spot 1mm dia. or more / 2mm dia. or more 3mm dia. or more Light receiving element Si Photodiode Light receiving area Approx. 10mm × 10mm / Approx. 18mm × 18mm Effective light receiving area *1 Approx. 9.5mm × 9.5mm / Approx. 15.5mm × 15.5mm Calibration wavelength *2 Standard OPT82314B+22/ OPT82314BW+22 OPT82314B+23/OPT82314BW+23 Measurement accuracy (at 1mW input) ±2.5% (at calibration wavelength) ±3.5% (390 to 900nm) Wavelength sensitivity correction range 390 to 900nm Shape Thin type Separation from a sensor section*4 Possible Dimensions (width) × (height) × (thickness of the light receiving section) mm 18×180×3.7/35.1×197×3.7 Model 82324B (Three-wavelength) Wavelength range 390 to 900nm Wavelength 405nm 650nm 780nm Power range Display in dBm −50 to +20dBm Display in W 10nW to 100mW Beam spot 1mm dia. or more 3mm dia. or more Light receiving element Si Photodiode Light receiving area Approx. 8.5mm dia. Effective light receiving area *1 Approx. 6.5mm dia. Calibration wavelength *2 Standard OPT82324B+22 OPT82324B+23 Measurement accuracy (at 1mW input) ±2.5% (at calibration wavelength) ±3.5%(390 to 900nm) Wavelength sensitivity correction range 390 to 900nm Shape Cylindrical type Dimensions (width) × (height) mm 38×40
  • 5. Head Office Shoei Bldg, 3-6-12, Kyobashi, Chuou-ku, Tokyo 104-0031, Japan Phone: +81-3-6272-4433 Fax: +81-3-6272-4437 Higashimatsuyama Office (R&D Center) 77-1, Miyako Namegawa-machi, Hiki-gun, Saitama 355-0812, Japan Phone: +81-493-56-4433 Fax: +81-493-57-1092 E-mail : kcc@adcmt.com URL : http://www.adcmt-e.com © 2011 ADC CORPORATION Printed in Japan 8230A-NP2E Oct. '11 AO 5 Sensor Characteristics (Typical Values) General-purpose sensor -60 120 100 80 60 40 20 -40 -20 0 20 40 60 deg 82311B Incident angle dependence (780nm) P polarization S polarization Circular polarization P polarization S polarization Circular polarization 0 50 40 30 20 10 0 10 20 30 40 50 60 deg 82311B Reflectance (780nm) 1 2 0 -2 -4 -6 -8 -10 10 100 Incident Power [mW] 82311B/82321B Power linearity (780nm) Beamφ0.1 Beamφ0.7 Beamφ3 Linearuty(%) Reflectance(%) 380 140 120 100 80 60 40 20 0 580 780 980 wavelength [nm] 82311B/82321B Wavelength sensitivity Sensitivity(%) Sensitivity(%) -60 120 100 80 60 40 20 -40 -20 0 20 40 60 deg 82312B/82322B Incident angle dependence (405nm) P polarization S polarization Circular polarization P polarization S polarization Circular polarization 0 50 40 30 20 10 0 10 20 30 40 50 60 deg 82312B/82322B Reflectance (405nm) 1 2 0 -2 -4 -6 -8 -10 10 100 Incident Power [mW] 82312B/82322B Power linearity (405nm) Beamφ0.1 Beamφ0.7 Linearuty(%) Reflectance(%) 400 101 100 99 98 97 95 0 405 410 415 420 wavelength [nm] 82312B/82322B Wavelength sensitivity Sensitivity(%) Sensitivity(%) -60 120 100 80 60 40 20 -40 -20 0 20 40 60 deg 82313B/82323B Incident angle dependence (780nm) P polarization S polarization Circular polarization 0 50 40 30 20 10 0 10 20 30 40 50 60 deg 82313B/82323B Reflectance (780nm) P polarization S polarization Circular polarization 1 2 0 -2 -4 -6 -8 -10 10 100 1000 Incident Power [mW] 82313B/82323B Power linearity Beamφ0.1 Beamφ0.7 Linearuty(%) Reflectance(%) 380 140 120 100 80 60 40 20 0 580 780 980 1180 wavelength [nm] 82313B/82323B Wavelength sensitivity Sensitivity(%) Sensitivity(%) Blue-violet sensor High-power sensor Sensor Characteristics (Typical Values) Three-wavelength sensor 0 120 100 80 60 40 20 10 20 30 40 50 60 deg 82314B/82314BW/32324B Incident angle dependence (405nm) 0 30 40 50 20 10 0 10 20 30 40 50 60 deg 82314B/82314BW/32324B Reflectance (405nm) 400 105 104 103 102 101 100 99 98 97 96 95 405 410 420 415 82314B/82314BW/32324B Wavelength sensitivity (405nm) Reflectance(%) wavelength [nm] Sensitivity(%) Sensitivity(%) 390 140 120 100 80 60 40 20 0 490 590 890 690 790 82314B/82314BW/32324B Wavelength sensitivity (all levels) wavelength [nm] Sensitivity(%) P polarization S polarization Circular polarization P polarization S polarization Circular polarization Dimensional Drawing 10 18 180 11 18 180 99 ∗ 5 受光素子面までの距離0.5mm 3.2 保護硝子面までの距離0.8mm 受光素子面までの距離1.8mm 3.2 Distance to the cover glass surface: 0.8mm Distance to the light receiving element surface: 1.8mm (8.5) 10 18 180 99 72.5 82311B 82312B/82313B 82314B ∗: Fixing screw hole M3 (5mm max.) ∗:Fixing screw hole M3 (5mm max.) ∗:Fixing screw hole M3 (6mm max.) 3.7 Distance to the cover glass surface: 0.1mm Distance to the light receiving element surface: 1.4mm Distance to the light receiving element surface: 2.15mm Distance to the cover glass surface: 0.65mm M33×1.5 φ 38 φ14 17.55 197 35.1 ∗ ∗ 82314BW 82324B (8.5) 76 1500 72.5 40 35 28 5 11 18 180 82313B 82312B 82314B 5 Distance to the light receiving element surface: 0.5mm 11 18 3.7 Distance to the cover glass surface: 0.1mm Distance to the light receiving element surface: 1.4mm 11 18 3.7 Distance to the cover glass surface: 0.3mm Distance to the light receiving element surface: 1.4mm 11 18 82312B/3B 82314B 8230 Optical Power Meter Perfect for use in R&D and production lines of next- generation optical discs and for evaluation of blue- violet and high-power lasers l A wide selection of optical sensors for different use l Three-wavelength optical sensors covering 405/650/780nm l Blue-violet optical sensors for 405nm laser measurement l High-power optical sensors for high-power laser measurement l Low-price general-purpose optical sensors l Both thin type and cylindrical type available l Optical power calibration wavelengths: 405/650/780nm l 5½-digit display and 0.001dB resolution l USB interface http://www.adcmt-e.com 82311B 82321B 82312B 82322B 82313B 82323B 82314B 82324B 82314BW 405 nm 405 nm 650 nm 650 nm 780 nm 780 nm
  • 6. Head Office Shoei Bldg, 3-6-12, Kyobashi, Chuou-ku, Tokyo 104-0031, Japan Phone: +81-3-6272-4433 Fax: +81-3-6272-4437 Higashimatsuyama Office (R&D Center) 77-1, Miyako Namegawa-machi, Hiki-gun, Saitama 355-0812, Japan Phone: +81-493-56-4433 Fax: +81-493-57-1092 E-mail : kcc@adcmt.com URL : http://www.adcmt-e.com © 2011 ADC CORPORATION Printed in Japan 8230A-NP2E Oct. '11 AO 5 Sensor Characteristics (Typical Values) General-purpose sensor -60 120 100 80 60 40 20 -40 -20 0 20 40 60 deg 82311B Incident angle dependence (780nm) P polarization S polarization Circular polarization P polarization S polarization Circular polarization 0 50 40 30 20 10 0 10 20 30 40 50 60 deg 82311B Reflectance (780nm) 1 2 0 -2 -4 -6 -8 -10 10 100 Incident Power [mW] 82311B/82321B Power linearity (780nm) Beamφ0.1 Beamφ0.7 Beamφ3 Linearuty(%) Reflectance(%) 380 140 120 100 80 60 40 20 0 580 780 980 wavelength [nm] 82311B/82321B Wavelength sensitivity Sensitivity(%) Sensitivity(%) -60 120 100 80 60 40 20 -40 -20 0 20 40 60 deg 82312B/82322B Incident angle dependence (405nm) P polarization S polarization Circular polarization P polarization S polarization Circular polarization 0 50 40 30 20 10 0 10 20 30 40 50 60 deg 82312B/82322B Reflectance (405nm) 1 2 0 -2 -4 -6 -8 -10 10 100 Incident Power [mW] 82312B/82322B Power linearity (405nm) Beamφ0.1 Beamφ0.7 Linearuty(%) Reflectance(%) 400 101 100 99 98 97 95 0 405 410 415 420 wavelength [nm] 82312B/82322B Wavelength sensitivity Sensitivity(%) Sensitivity(%) -60 120 100 80 60 40 20 -40 -20 0 20 40 60 deg 82313B/82323B Incident angle dependence (780nm) P polarization S polarization Circular polarization 0 50 40 30 20 10 0 10 20 30 40 50 60 deg 82313B/82323B Reflectance (780nm) P polarization S polarization Circular polarization 1 2 0 -2 -4 -6 -8 -10 10 100 1000 Incident Power [mW] 82313B/82323B Power linearity Beamφ0.1 Beamφ0.7 Linearuty(%) Reflectance(%) 380 140 120 100 80 60 40 20 0 580 780 980 1180 wavelength [nm] 82313B/82323B Wavelength sensitivity Sensitivity(%) Sensitivity(%) Blue-violet sensor High-power sensor Sensor Characteristics (Typical Values) Three-wavelength sensor 0 120 100 80 60 40 20 10 20 30 40 50 60 deg 82314B/82314BW/32324B Incident angle dependence (405nm) 0 30 40 50 20 10 0 10 20 30 40 50 60 deg 82314B/82314BW/32324B Reflectance (405nm) 400 105 104 103 102 101 100 99 98 97 96 95 405 410 420 415 82314B/82314BW/32324B Wavelength sensitivity (405nm) Reflectance(%) wavelength [nm] Sensitivity(%) Sensitivity(%) 390 140 120 100 80 60 40 20 0 490 590 890 690 790 82314B/82314BW/32324B Wavelength sensitivity (all levels) wavelength [nm] Sensitivity(%) P polarization S polarization Circular polarization P polarization S polarization Circular polarization Dimensional Drawing 10 18 180 11 18 180 99 ∗ 5 受光素子面までの距離0.5mm 3.2 保護硝子面までの距離0.8mm 受光素子面までの距離1.8mm 3.2 Distance to the cover glass surface: 0.8mm Distance to the light receiving element surface: 1.8mm (8.5) 10 18 180 99 72.5 82311B 82312B/82313B 82314B ∗: Fixing screw hole M3 (5mm max.) ∗:Fixing screw hole M3 (5mm max.) ∗:Fixing screw hole M3 (6mm max.) 3.7 Distance to the cover glass surface: 0.1mm Distance to the light receiving element surface: 1.4mm Distance to the light receiving element surface: 2.15mm Distance to the cover glass surface: 0.65mm M33×1.5 φ 38 φ14 17.55 197 35.1 ∗ ∗ 82314BW 82324B (8.5) 76 1500 72.5 40 35 28 5 11 18 180 82313B 82312B 82314B 5 Distance to the light receiving element surface: 0.5mm 11 18 3.7 Distance to the cover glass surface: 0.1mm Distance to the light receiving element surface: 1.4mm 11 18 3.7 Distance to the cover glass surface: 0.3mm Distance to the light receiving element surface: 1.4mm 11 18 82312B/3B 82314B 8230 Optical Power Meter Perfect for use in R&D and production lines of next- generation optical discs and for evaluation of blue- violet and high-power lasers l A wide selection of optical sensors for different use l Three-wavelength optical sensors covering 405/650/780nm l Blue-violet optical sensors for 405nm laser measurement l High-power optical sensors for high-power laser measurement l Low-price general-purpose optical sensors l Both thin type and cylindrical type available l Optical power calibration wavelengths: 405/650/780nm l 5½-digit display and 0.001dB resolution l USB interface http://www.adcmt-e.com 82311B 82321B 82312B 82322B 82313B 82323B 82314B 82324B 82314BW 405 nm 405 nm 650 nm 650 nm 780 nm 780 nm https://www.n-denkei.com/singapore/inquiry/