NO.59-1501-3

                                                               INSTALLATION INSTRUCTIONS
                     High Mount
                     Outdoor Detector                                                     N219
                     HX-40/40AM/
                     40DAM
                                                            CONTENTS
                                                          1 INSTALLATION PRECAUTIONS ............2
        HX-40    2 PIRs standard model                      1-1 BEFORE INSTALLATION ................2
        HX-40AM  HX-40 with anti-masking                    1-2 PARTS IDENTIFICATION ................3
        HX-40DAM HX-40AM with micro-wave                    1-3 KNOCKOUTS ..................................4
      • 3.0 m high mount detection area (12.0 m)            1-4 DETECTION AREA..........................5
                                                            1-5 DETERMINATION OF PIR
      • Unique pyro element                                     DETECTION LENGTH ....................5
                                                          2 INSTALLATION.......................................6
      • Intelligent AND logic
                                                            2-1 MOUNTING WITH BRACKET .........6
      • Dual signal processing logic                        2-2 ADJUSTING THE VERTICAL
                                                                ANGLE.............................................8
      • Vegetation sway analysis logic                      2-3 MOUNTING WITHOUT
                                                                BRACKET ........................................9
      • Ideal detection area setting                        2-4 WIRING .........................................10
                                                            2-5 WALL TAMPER (OPTION) ............ 11
      • Digital anti-masking (AM/DAM model only)
                                                          3 WALK TEST..........................................12
      • Microwave range selector (DAM model only)         4 SETTING ..............................................13
                                                          5 AREA ADJUSTMENT ...........................16
                                                          6 LED INDICATION .................................17
                                                          7 SPECIFICATIONS ................................18
                                                            7-1 SPECIFICATIONS .........................18
                                                            7-2 DIMENSIONS ................................19




                                                    -1-



HX-40DAM_EN.indd 1                                                                                      2010/06/24 14:11:55
1     INSTALLATION PRECAUTIONS

            1-1      BEFORE INSTALLATION
                               Failure to follow the instructions provided with this indication and improper
                  Warning      handling may cause death or serious injury.
                               Failure to follow the instructions provided with this indication and improper
                  Caution      handling may cause injury and/or property damage.
           The check    mark indicates recommendation.
           The nix   sign indicates prohibition.
                        Warning                            Warning                         Caution




            Do not repair or modify
            product                            Keep product away from water Mount the unit securely

            Mounting height                    Keep the detector parallel to the ground.




                              2.5 m – 3.0 m
                              (8'2" – 9'10")                     Parallel                  Tilt




            Consider the direction a person is approaching from, as well as the detection area.




            Install the detector in a place where it is free from false alarm factors. For example:
             • Sunlight and reflection        • Heat source                     • Objects moving in the wind




                                                        -2-



HX-40DAM_EN.indd 2                                                                                   2010/06/24 14:11:57
HX-40
                                                                                                                    HX-40AM
             -Precautions for installing two or more sensors                                                       HX-40DAM

             Do not install two or more HX-40DAM’s units side-by-side or face-to-face. Instead, install them
             back-to-back. If mounting on the same wall, be sure they are at least 1.0 m (3'3") apart from
             each other.




               1.0 m (3'3") or more          Less than 1.0 m (3'3")


              1-2        PARTS IDENTIFICATION
              Bracket base            Base
                                                                                                    Screw (3 × 10 mm)


                                                             Terminals      Main unit




                                                                                                                                Hood
                                                                                   PIR sensor
                                                                                   (Do not touch)

                 Bracket                                                           Anti-masking infrared LED
                                                                                   (HX-40AM/DAM only)
             Shaft cover

                     Lock screw* (M4 × 35 mm)

                           Screw (4 × 20 mm)

                                                         Microwave unit
                                                         (HX-40DAM only)
                                                         (Do not touch)                                                 Lens
                                                                     LED indicator
                                                                                                                        Cover

                                                                                                                        Lock screw



                                                                                   Area masking seal




             Screw kit
             For joint              For wall mounting   For hood
             Screw (4 × 20 mm)      Screw (4 × 20 mm)   Screw (3 × 10 mm)



             *Lock screw attached on bracket base




                                                              -3-



HX-40DAM_EN.indd 3                                                                                                      2010/06/24 14:11:58
1-3      KNOCKOUTS

               Main unit                                              Bracket

                                                                         Wiring Hole




              Wiring
              knockout                                                                             (Off-the-shelf) magnet switch
                                                                                                   installation position




                                                                                                                    Wiring Hole




                                             Wiring sponge pad


                                                                                                                   Do not touch
                                                                     For wall               For switch      Up-Down
                                                                     fastening              box fastening   lock screw
           For bracket        For wall fastening/bracket fastening
                                                                                 Adjustment screw      For main unit fastening
           Up-Down lock screw (installation pitch 83.5 mm (3.29"))




                                                              -4-



HX-40DAM_EN.indd 4                                                                                                    2010/06/24 14:11:58
1-4                 DETECTION AREA
                     Side view                                                                           Top view
                     (Mounting height: 3.0 m (9'10"))
                                                                                                   0'                    10'       20'       30'        40'
                                                                                                                                                        40'
                             0'                    10'     20'       30'     40' (ft.)                                                                   (ft.)
                                                                                         (ft.) (m)                  2          4   6     8         10   12
                                                         12.0 m
             (ft.)                                                                              8                                                        (m)
                                                                                MW
              10'
                                                                                PIR      20'   6
                     3.0 m




                                                                                                                                                                           40°
               5'




                                                                                                                                                                         30°
               0'                                                                              4




                                                                                                                                                                  20°
                                                                                         10'
                                                                                               2
                     (Mounting height: 2.5 m (8'2"))




                                                                                                                                                         10°




                                                                                                                                                                                  85°
                             0'                    10'     20'       30'     40' (ft.)    0'   0

                                                         12.0 m                                2
             (ft.)
              10'                                                              MW        10'                                                                                PIR
                                                                               PIR             4
                     2.5 m




               5'

               0'                                                                        20'   6
                                                                                                                                                                                  MW
                     • Vertical angle: 1 click (2.5°) upward
                                                                                                8
                       (Refer to “caution” in 2-2).                                      (ft.) (m)




              1-5                 DETERMINATION OF PIR DETECTION LENGTH
             To adjust the detection length, apply the masking seals to the back of the lens according to
             the required detection length. Three types of masking seals are provided. Combine them
             according to the detection length required.




                                                                 Apply masking seal directly on the back side of the lens.




                                                          9.0 m (29'6")                                                 5.5 m (18'1")                                     4.0 m (13'1")
                                   3.0 m (9'10")




                                                                                                    3.0 m (9'10")




                                                                                                                                                         3.0 m (9'10")




               1                                                                   1                                                         1
                                                                                                                                             3
                                                                                   2                                                         2




             For microwave detection setting please refer to “4 SETTING”.




                                                                                       -5-



HX-40DAM_EN.indd 5                                                                                                                                                           2010/06/24 14:11:59
2     INSTALLATION
           Use the bracket for normal installation. The unit may be mounted directly on the wall, without
           the bracket, only if the following three conditions are not;
           • The mounting height 3.0 m (9'10").
           • Horizontal direction adjustment is unnecessary.
           • The ground is level.


            2-1       MOUNTING WITH BRACKET
           Using the bracket makes it possible to adjust the unit horizontally by ±90°.
           In cases where the ground is uneven and/or not parallel with the base of the unit, it is possible
           to adjust the unit vertically by ±20°.



                                                                              Caution>>
                                                                              Do not change the detection
                                                                              length with bracket.
                                                                              Use the masking seal to
                                                                              adjust the detection length.
                     90°                      90°
                                                             20°
                                                             20°




                  Remove the Up-Down lock screw.                   Push the shaft cover clip straightforwardly with
             1                                               2     your thumb. In case the clip is stuck, use a
                                                                   suitable tool. e.g. back side of a screw driver.
                                                                                    Shaft cover
                                                                                    Shaft cover clip




                  Loosen the adjustment screw two turns.           Tilt the bracket about 45° and pass
             3                                               4     through the wire.


                                                              In
                           Adjustment screw                                                                  Out

              Caution>>
              Do not loosen the
              screw too much.
              It may disassemble.


                                                     -6-



HX-40DAM_EN.indd 6                                                                                        2010/06/24 14:11:59
Determine the horizontal direction (left or            Open the wiring knockout.
              5      right) of the detector before installing the
                                                                      6
                     bracket on the wall.
                     To the right                     To the left




                                                                                                  Wiring knockout




                     Open the Up-Down lock screw knockout                   Tighten screws 1 and 2, adjust the bracket
              7      for connecting the bracket.
                                                                     8      angle (refer to 2-2), then tighten screw 3.
                                                                            Perform an area check. If re-adjustment is
                                                                            required, loosen screw 3 and change the
                                                                            bracket angle.
                                                                            After the adjustment is complete, tighten
                                                                            screw 3 again.




                                                                       In

                               Knockout with 4 × 20
                               tapping screw (screwkit)
                                                                     Wiring
                                                                     hole Wiring
                                                                            sponge pad                          14 × 20 screw
                                                                                                          Out
                                                                                                            34 × 35 Up-Down
                                                                                                              lock screw
                                                                                                            24 × 20 screw

                     Tighten the adjustment screw clockwise.
              9                                                      10 Wireandthe terminal and install the main
                                                                        unit
                                                                             to
                                                                                lens on the base.


                  Adjustment
                  screw




                     Install the shaft cover into place.
             11

                                                               -7-



HX-40DAM_EN.indd 7                                                                                              2010/06/24 14:12:00
2-2      ADJUSTING THE VERTICAL ANGLE
           For best performance, install detector parallel to the ground.
           Decide the detection length. If you choose 9.0 m/5.5 m/4.0 m, mask the unnecessary lens with
           masking seals. Refer to the 1-5 for the details.
                                                                                         12.0 m (40')




            Perform the walk test to check


                                                 3.0 m (9'10")
            if detector is parallel to the
            ground.

                                                                 * This is the case to have 12 m detection length.


             If the detection length is
             shorter than the designated
             one (refer to page 5), change                                       If the detection length is
             the detector angle upward.                                          equal to the designated
                                                                                 one, adjustments have
             If the detection length is                                          been completed.
             longer than the designated
             one (refer to page 5), change
             the detector angle downward.




              Caution>>
              If the base of the unit is already parallel to the ground,
              • Do not change the detection length by tilting the unit up or down. Detection length should
                 be adjusted with masking seal. Refer to 1-5 and 2-1 for the details.

                                                                                            0°
                Example (the ground is level)                                                    2 clicks (5°)
                                                                                                 4 clicks (10°)
                0° is the right setting for 3.0 m
                (9'10") height installation.
                Adjust 1 click (2.5° upward) for 2.5 m
                (8'2") height installation.




                                                                 -8-



HX-40DAM_EN.indd 8                                                                                                   2010/06/24 14:12:01
2-3       MOUNTING WITHOUT BRACKET
                     Open the wiring knockout with suitable           Pull the wire through the base knockout.
              1      tool e.g. screwdriver.
                                                               2




                                                                 In

                                                                                                          Out


                                                              Wiring sponge pad



                     Fasten the base to the wall.                     Install main unit after wiring to the
              3                                                4      terminal.




                                                        -9-



HX-40DAM_EN.indd 9                                                                                      2010/06/24 14:12:01
2-4       WIRING
           Power wires should not exceed the following lengths.
                                          HX-40                 HX-40AM                                                        HX-40DAM
             WIRE GAUGE
                                    12 V        14 V        12 V        14 V                                                 12 V      14 V
                                   160 m       360 m       140 m       310 m                                                120 m     250 m
            AWG22 (0.33 mm ) 2
                                   (520')     (1,180')     (460')     (1,020')                                              (390')    (820')
                                   260 m       560 m       230 m       490 m                                                180 m     390 m
            AWG20 (0.52 mm ) 2
                                   (850')     (1,840')     (750')     (1,610')                                              (590')   (1,280')
                                   410 m       900 m       360 m       780 m                                                290 m     630 m
            AWG18 (0.83 mm2)
                                  (1,350')    (2,950')    (1,180')    (2,560')                                              (950')   (2,070')




                                                                                                                                                                                                                          POWER INPUT (+) (9.5 - 18VDC)
                                                                                                                                                                                          POWER INPUT (-) (9.5 - 18VDC)
                                                                                                                                               ALARM OUTPUT (COM)
                                                                                                                         ALARM OUTPUT (N.O.)


                                                                                                                                                                    ALARM OUTPUT (N.C.)
                                                                                   TROUBLE OUTPUT


                                                                                                     SPARE (Non short)
                                                    TAMPER OUTPUT


                                                                     AUX INPUT
                                                    (N.C.) *1




                                                                                   (N.C.)
                                                                     (N.C.)




                                     HX-40AM
                                     HX-40DAM




                                                  TAMPER              AUX        TROUBLE                                 N.O. COM N.C. –     +
                                                                                            SP                     SP
                                                                    INPUT         OUTPUT                                     ALARM     POWER
                                                    (N.C.)           (N.C.)      T.O.(N.C.)                                           9.5-18VDC

                                     HX-40




                                                  TAMPER              AUX                                                N.O. COM N.C. –     +
                                                                                                    SP             SP
                                                                    INPUT                                                    ALARM     POWER
                                                    (N.C.)           (N.C.)                                                           9.5-18VDC

                                    *1: TAMPER terminals to be connected to a 24 hour supervisory loop.




                                                  - 10 -



HX-40DAM_EN.indd 10                                                                                                                                                                                           2010/06/24 14:12:01
2-5         WALL TAMPER (OPTION)
             Universal magnet switch may be mounted as a wall tamper.
             Installation space for universal magnet switch is provided on the back of the main unit and the
             bracket.
             Maximum size of an applicable universal magnet switch: D 9 mm (0.35'') × W 40 mm (1.57'') × H 9
             mm (0.35'').
             Universal magnet switch on the market assist is not included.
                    Main unit                                                                Bracket
                                                                                                      Wiring Hole




                                                                                                                   Magnet switch
                                                                                                                   (Bracket side)
                                                                                         Magnet switch (Wall side) installation position
                                                 Magnet switch (Wall side)               installation position
                                                 installation position

                                       Magnet switch (Base side) installation position


             -Installation
                  Install the universal magnet switch (wall                          Open the wiring knockout with suitable
              1   side) to the wall. To determine the install
                                                                                2    tool e.g. screwdriver.
                  position, use the “Install position template”
                  provided on the inside cover of the product
                  package.




                  Install the other portion of the universal magnet switch to the back of the main unit or the
              3   bracket. Pull the wiring through the knockouts.
                                When not using the bracket


                                                   1   Fix

                      2    In




                    4     Wiring sponge pad
                                                                     Out   3


                                                                    - 11 -



HX-40DAM_EN.indd 11                                                                                                                2010/06/24 14:12:02
When using the bracket


                                1   Fix                            In
                                                                   4
            In
            2
                                 Tilt the bracket about 45° and
                                 pass through the wire.


                                                                   6
            In                                               3     Wiring                                    5
                                                             Out                                                 Out
                                                                   sponge pad



            Magnet
            switch

                   Install the bracket and the main unit to                 Connect the universal magnet switch wiring
            4      the wall surface.
                                                                        5   to the tamper terminal of the main unit.


      3     WALK TEST
                   Set the DIP switch 1 (LED ON/OFF) to                     Check that the detector detects an
            1      “ON”.
                                                                        2   object in the intended detection area.
                                                                            The installation has been successful if
                                                                            the LED lights for two seconds after a
                                                                            person walks into the detection area.




                                                                                    Detected
                                                                                                    Not detected

                 Note>>
                 The switch is set “ON” by factory
                 default.
                                                                        Note>>
                                                                        For the walk test, move more than 1.0 m
                                                                        (3'3") away from the detector.

                   If the LED indication is not required at all
             3     times, set the DIP switch 1 (LED ON/
                   OFF) to “OFF”.




                                                              - 12 -



HX-40DAM_EN.indd 12                                                                                           2010/06/24 14:12:02
4     SETTING
                                                                       Do not touch




             DIP switch                                                                                       MW range
              1.   LED ON/OFF                                                                                 selector
              2.   PIR IMMUNITY
              3.   AUX INPUT
                                                                                                              MW sensitivity
              4.   TROUBLE OUTPUT
                                                                                                              adjustment
              5.   MICROWAVE IMMUNITY
              6.   (Reserved)

                                                                                                         HI
                                                                                                        STD   Anti masking
                                                                                                        OFF
                                                                                                              sensitibity
                                                                                                              selector
                                                                        Do not touch
                                PIR sensitivity selector


                                                                                                                HX-40
                                                                                                               HX-40AM
             -LED ON/OFF                                                               DIP switch   1         HX-40DAM

                                                           POSITION                           FUNCTION
                                                              ON
                                                                              The LED lights when someone is
                                                            (Factory
                                                                              detected.
                                                            default)
                                                                              The LED does not light even if
                                                             OFF
                                                                              someone is detected.

                          OFF        ON
                                                                                                                HX-40
                                                                                                               HX-40AM
             -PIR IMMUNITY                                                             DIP switch   2         HX-40DAM

                                                           POSITION                           FUNCTION
                                                              STD
                                                            (Factory          PIR IMMUNITY logic is not activated.
                                                            default)
                                                                              PIR IMMUNITY logic is activated. Use
                                                           IMMUNITY           this under harsh environment (e.g.
                                                                              small animal).
                          STD        IMMUNITY




                                                           - 13 -



HX-40DAM_EN.indd 13                                                                                             2010/06/24 14:12:03
HX-40
                                                                                                HX-40AM
           -AUX INPUT                                                     DIP switch   3       HX-40DAM

           By connecting a satellite unit (another warning sensor), you can extend the detection area
           and correct false alarms. As a satellite unit, you can use any general no-voltage contact
           output (NC) warning sensor, including the following.
           <Infrared (AIR) sensors, thermal line (PIR) sensors, universal magnet switches, etc.>
                              POSITION                               FUNCTION

                                 AND          When both the main unit and the satellite detect someone, the
                               (Factory       alarm is output.
                               default)       Set to this when not connecting a satellite unit.

                                              When either the main unit or the satellite detects someone,
                                 OR
                                              the alarm is output.
            AND       OR      Notes>>
                              • The alarm does not output unless both the main unit and the satellite
                                detect someone within 60 sec.
                              • If the OR mode is selected without a satellite unit connected, the alarm
                                is generated continuously.
                                                                                                 HX-40
                                                                                                HX-40AM
           -TROUBLE OUTPUT                                                DIP switch   4       HX-40DAM

           Trouble output is used for anti-masking signal.
           When an object is placed close to the lens surface, for a period of more than 180 sec., the IR
           Anti-Masking circuit is activated and generates a trouble signal.

                              POSITION                               FUNCTION
                                 ON
                                              Anti-masking signal is output from TROUBLE OUTPUT
                               (Factory
                                              terminal.
                               default)
                                              Anti-masking signal is output from both TROUBLE and
                                 OFF
                                              ALARM OUTPUT terminal.

                              Note>>
            OFF       ON      Use this when not wiring a detected trouble input terminal on the control
                              panel.
                                                                                                 HX-40
                                                                                                HX-40AM
           -MICROWAVE IMMUNITY                                            DIP switch   5       HX-40DAM

                              POSITION                               FUNCTION
                                 STD
                               (Factory       MICRO WAVE IMMUNITY logic is not activated.
                               default)
                                              MICRO WAVE IMMUNITY logic is activated. Use this
                             IMMUNITY
                                              under harsh environment (e.g. vegetation sway).

            STD       IMMUNITY




                                                   - 14 -



HX-40DAM_EN.indd 14                                                                                 2010/06/24 14:12:03
RANGE SELECTOR/         HX-40
                                                                        SENSITIVITY          HX-40AM
             -MW RANGE SELECTOR/MW SENSITIVITY ADJUSTMENT               ADJUSTMENT          HX-40DAM

                                            DETECTION AREA           MW RANGE      MW SENSITIVITY
                PIR AREA SETTING
                                              (SIDE VIEW)            SELECTOR       ADJUSTMENT



                                                                      LONG               MID
              12.0 m                                                                    M
               (40')                    0
                                                                      SHORT

                                                               PIR
                                                                          LONG
                                                                                        L      H
                                                               MW
                      Factory default



                         1                                            SHORT             HIGH
               9.0 m                                                                    M
                                                                       SHORT
              (29'6'')                  0


                                                         PIR
                                                                                        L      H
                                                         MW               LONG




                         1                                            SHORT              MID
               5.5 m                                                                    M
              (18'1'')   2                                            SHORT
                                        0
                                                   PIR
                                                   MW
                                                                          LONG
                                                                                        L      H




                         1
                                                                      SHORT             LOW
               4.0 m     3                                                              M
              (13'1'')   2              0
                                                                      SHORT
                                                 PIR
                                                 MW
                                                                                        L      H
                                                                          LONG




                                                  - 15 -



HX-40DAM_EN.indd 15                                                                           2010/06/24 14:12:03
HX-40
                                                                                                              PIR
                                                                                                                                            HX-40AM
           -PIR SENSITIVITY                                                                      SENSITIVITY SELECTOR                      HX-40DAM

                                                                 POSITION                                           FUNCTION
                                        HIGH
                                                                     HIGH                        High sensitivity
                                                                   MIDDLE
                                      MIDDLE                                                     Middle sensitivity
                                                               (Factory default)

                                        LOW                          LOW                         Low sensitivity
                                                                                                                                             HX-40
                                                                                                      ANTI-MASKING
                                                                                                                                            HX-40AM
           -ANTI-MASKING SENSITIVITY                                                             SENSITIVITY SELECTOR                      HX-40DAM

                                                                 POSITION                                           FUNCTION
                                                                     HIGH                        High sensitivity
                                        HIGH                         STD
                                                                                                 Standard sensitivity
                                                               (Factory default)
                                        STD                          OFF                         Disabled

                                        OFF                    Caution>>
                                                               When closing the cover, do not leave any object within
                                                               1 meter from the unit.


      5     AREA ADJUSTMENT
           -DETECTION LENGTH ADJUSTMENT
           To limit the detection length, apply the appropriate masking seal. Note that there are three
           different types of seal.
                                           9.0 m (29'6")                                    5.5 m (18'1")                                         4.0 m (13'1")
                                                                                                                                  3.0 m (9'10")
                      3.0 m (9'10")




                                                                            3.0 m (9'10")




            1                                                    1                                                   1
                                                                                                                     3
                                                                 2                                                   2




           -AREA MASKING
                                                                                                                  Pasting on example for
                                                                                             1                    masking No. 5 and No. 6

                                                                                                  2

                                                                                                      3
                      1
                      2               Area masking seal
                      3                                                                                   4
                      4
                      5                                    0                                                  5              56
                      6
                      7
                      8                                                                                       6
                      9
                                                                                                      7

                                                                                                  8

                                                                                             9


                                                                 - 16 -



HX-40DAM_EN.indd 16                                                                                                                                  2010/06/24 14:12:04
6     LED INDICATION

                                      Red


                                              Yellow               Blink      Light      OFF
                                              (HX-40DAM only)
                                  Green
                                  (HX-40DAM only)
             -HX-40/40AM
              DETECTOR CONDITION                             LED INDICATOR (RED ONLY)

                        Warm-up
                                                                Blinks for approx. 60 sec.

                         Alarm
                                                                     Lights for 2 sec.
                           Anti-Masking
                             booting
                          (Anti-Masking
                             start up)      Blinks 2 times and goes off for 5 sec. and then repeats for 180 sec.
             Trouble
             output
                        Masking detection
                                                  Blinks 3 times and goes off for 3 sec. and then repeats.
             -HX-40DAM
              DETECTOR CONDITION                                    LED INDICATOR

                        Warm-up
                                                                Blinks for approx. 60 sec.

                         Alarm
                                                                   Red lights for 2 sec.

                      PIR detection
                                                                  Green lights for 2 sec.

                      MW detection
                                                                  Yellow lights for 2 sec.
                           Anti-Masking
                             booting
                          (Anti-Masking
                                               Green and Red blink 2 times simultaneously and go off for
                             start up)
             Trouble                                5 sec. This sequence is repeated for 180 sec.
             output

                        Masking detection
                                               Green and Red blink 3 times simultaneously and go off for
                                                          3 sec. This sequence is repeated.
                                                       - 17 -



HX-40DAM_EN.indd 17                                                                                   2010/06/24 14:12:04
7     SPECIFICATIONS

            7-1       SPECIFICATIONS
             Model                                 HX-40                          HX-40AM                         HX-40DAM
             Detection method                                  Passive infrared                          Passive infrared & Microwave

             PIR Coverage                                             12.0 m (40') 85° wide / 94 zones
             PIR distance limit                                    4.0 m, 5.5 m, 9.0 m (13'1", 18'1", 29'6")
             Detectable speed                                         0.3 m/s – 1.5 m/s (1'/s – 4'11"/s)
             Sensitivity                                                   2.0°C (3.6°F) at 0.6 m/s
             Power input                                                          9.5 – 18 V DC
                                                35 mA (max.)                      40 mA (max.)                    50 mA (max.)
             Current draw                                                                                          at 12 V DC
                                                 at 12 V DC                        at 12 V DC
             Alarm period                                                          2.0 ±1 sec.
             Warm-up period                                             Approx. 60 sec. (LED blinks)
             Alarm output                                               Form C 28 V DC 0.2 A (max.)
             Tamper output                             N.C. 28 V DC, 0.1 A (max.) N.C. open when cover removed.
             Trouble output                            –                                     N.C. 28 V DC, 0.1 A (max.)
             Aux input                                                   N.C. 28 V DC, 0.1 A (max.)
                                                                                                           Red:
                                                                                                           Warm-up, Alarm, Trouble
                                                                           Red: Warm-up,
                                               Red: Warm-up,                                               Green:
             LED indicator                                                       Alarm,
                                                    Alarm                                                  Warm-up, PIR detect, Trouble
                                                                                 Trouble
                                                                                                           Yellow:
                                                                                                           Warm-up, MW detect
             RF interference                                                  No alarm 10 V/m
             Operating temperature                                       -20 – +60°C (-4 – +140°F)
             Environment humidity                                                   95% max.
             Weatherproof                                                             IP55
             Mounting                                                                 Wall
             Mounting height                                              2.5 – 3.0 m (8'2" – 9'10")
             Bracket adjust angle                                      Vertical: ±20° Horizontal: ±95°
             Weight                                            600 g (21.2 oz.)                                  700 g (24.7 oz.)
             Accessories                        Bracket, Hood, Area masking seal, Screw (3 × 10 mm) × 2, Screw (4 × 20 mm) × 4
           *Specifications and designs are subject to change without prior notice.




                                                           - 18 -



HX-40DAM_EN.indd 18                                                                                                             2010/06/24 14:12:05
7-2     DIMENSIONS
               Using bracket and hood                              Without bracket and hood




                            266 (10.47)   99 (3.90)
                                                                       148 (5.83)             92 (3.62)




                                                                                                          197.5 (7.78)
                                                      205 (8.07)



                                          Unit: mm (inch)                                 Unit: mm (inch)




                                           - 19 -



HX-40DAM_EN.indd 19                                                                                2010/06/24 14:12:05
NOTE
            The following statement will be provided with the equipment as required by Article 6.3 of the
            R&TTE Directive, 1999/5/EC.
            The Optex HX series are in conformity with all essential requirements of the R&TTE Directive
            (1999/5/EC). This equipment has been assessed to the following standards:
            EN 300 440-1: 2009
            EN 50130-4: 2004 including amendment 2: 2003
            EN 60950-1: 2006+A11: 2009

            This product is marked with            which signifies conformity with Class II product
            requirements specified in the R&TTE Directive.
            The following table indicates the areas of intended use of the equipment and any known
            restrictions. For countries not included in this list, please consult the responsible Spectrum
            Management Agency.


             Country of intended use Restrictions Country of intended use Restrictions

               Austria                9.900GHz      Luxembourg                10.525GHz
               Belgium               10.525GHz      The Netherlands           10.525GHz
               Denmark               10.525GHz      Spain                     10.525GHz
               Finland                9.900GHz      Sweden                    10.525GHz
               France                10.587GHz      United Kingdom            10.587GHz
               Greece                10.525GHz      Other non-EU: Iceland     10.525GHz
               Ireland               10.587GHz      Norway                    10.525GHz
               Italy                 10.525GHz      Switzerland               10.525GHz
            FCC ID : DC9 OPMW              IC : 4012A-OPMW
            This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
            conditions:
            (1) This device may not cause harmful interference, and (2) this device must accept any
            interference received, including interference that may cause undesired operation.

            The HX-40 series is only a part of a complete system, therefore we cannot accept complete
            responsibility for any damages or other consequences resulting from an intrusion.




     OPTEX CO., LTD. (JAPAN) OPTEX INCORPORATED (USA)                             OPTEX SECURITY Sp. z o. o. (POLAND)
                                         TEL:+1-909-993-5770                      TEL:+48-22-598-06-55
     (ISO 9001 Certified)
                                         Tech:(800)966-7839                       URL:http://www.optex.com.pl/
     (ISO 14001 Certified)               URL:http://www.optexamerica.com/
     5-8-12 Ogoto Otsu
     Shiga 520-0101                      OPTEX (EUROPE) LTD. (UK)                 OPTEX KOREA CO., LTD. (KOREA)
     JAPAN                               TEL:+44-1628-631000                      TEL:+82-2-719-5971
                                         URL:http://www.optexeurope.com/          URL:http://www.optexkorea.com/
     TEL:+81-77-579-8670
     FAX:+81-77-579-8190
     URL:http://www.optex.co.jp/e/       OPTEX SECURITY SAS (FRANCE) OPTEX (DONGGUAN) CO., LTD.
                                         TEL:+33-437-55-50-50        SHENZHEN OFFICE (CHINA)
                                         URL:http://www.optex-security.com/       TEL:+86-755-33302950
                                                                                  URL:http://www.optexchina.com/




                                                           - 20 -



HX-40DAM_EN.indd 20                                                                                                2010/06/24 14:12:05

More Related Content

What's hot

Roland Edirol LVS-800
Roland Edirol LVS-800Roland Edirol LVS-800
Roland Edirol LVS-800AV ProfShop
 
Manual do piano digital Fenix TG8810 (PORTUGUÊS)
Manual do piano digital Fenix TG8810 (PORTUGUÊS)Manual do piano digital Fenix TG8810 (PORTUGUÊS)
Manual do piano digital Fenix TG8810 (PORTUGUÊS)Habro Group
 
Sennheiser EW-100-ENG-G3
Sennheiser EW-100-ENG-G3Sennheiser EW-100-ENG-G3
Sennheiser EW-100-ENG-G3AV ProfShop
 
Avtron Encoders Catalog
Avtron Encoders CatalogAvtron Encoders Catalog
Avtron Encoders CatalogJim Milbaugh
 
Manual do piano digital Fenix SP-20 (PORTUGUÊS)
Manual do piano digital Fenix SP-20 (PORTUGUÊS)Manual do piano digital Fenix SP-20 (PORTUGUÊS)
Manual do piano digital Fenix SP-20 (PORTUGUÊS)Habro Group
 
Dienhathe.com acb-3 wl
Dienhathe.com acb-3 wlDienhathe.com acb-3 wl
Dienhathe.com acb-3 wlDien Ha The
 
Abx micros 60 manual
Abx micros 60 manualAbx micros 60 manual
Abx micros 60 manualyam39
 

What's hot (9)

Roland LVS-800
Roland LVS-800Roland LVS-800
Roland LVS-800
 
Roland Edirol LVS-800
Roland Edirol LVS-800Roland Edirol LVS-800
Roland Edirol LVS-800
 
Manual do piano digital Fenix TG8810 (PORTUGUÊS)
Manual do piano digital Fenix TG8810 (PORTUGUÊS)Manual do piano digital Fenix TG8810 (PORTUGUÊS)
Manual do piano digital Fenix TG8810 (PORTUGUÊS)
 
Sennheiser EW-100-ENG-G3
Sennheiser EW-100-ENG-G3Sennheiser EW-100-ENG-G3
Sennheiser EW-100-ENG-G3
 
Avtron Encoders Catalog
Avtron Encoders CatalogAvtron Encoders Catalog
Avtron Encoders Catalog
 
Manual do piano digital Fenix SP-20 (PORTUGUÊS)
Manual do piano digital Fenix SP-20 (PORTUGUÊS)Manual do piano digital Fenix SP-20 (PORTUGUÊS)
Manual do piano digital Fenix SP-20 (PORTUGUÊS)
 
Adw535
Adw535 Adw535
Adw535
 
Dienhathe.com acb-3 wl
Dienhathe.com acb-3 wlDienhathe.com acb-3 wl
Dienhathe.com acb-3 wl
 
Abx micros 60 manual
Abx micros 60 manualAbx micros 60 manual
Abx micros 60 manual
 

Viewers also liked (20)

Imz ns100 brochure-final3-09
Imz ns100 brochure-final3-09Imz ns100 brochure-final3-09
Imz ns100 brochure-final3-09
 
Hvd 890 p1
Hvd 890 p1Hvd 890 p1
Hvd 890 p1
 
Hd 16 dvr-c-ds
Hd 16 dvr-c-dsHd 16 dvr-c-ds
Hd 16 dvr-c-ds
 
Lhm 060600
Lhm 060600Lhm 060600
Lhm 060600
 
Marketing plan-Harnest Label Industries,BD
Marketing plan-Harnest Label Industries,BDMarketing plan-Harnest Label Industries,BD
Marketing plan-Harnest Label Industries,BD
 
Cartaz Pb
Cartaz PbCartaz Pb
Cartaz Pb
 
Msute Andry Bonilla
Msute Andry BonillaMsute Andry Bonilla
Msute Andry Bonilla
 
Iclass 205x
Iclass 205xIclass 205x
Iclass 205x
 
MSUTE_Erika_Avendaño
MSUTE_Erika_AvendañoMSUTE_Erika_Avendaño
MSUTE_Erika_Avendaño
 
03 15 09 Course Schedule And Content Communication Keys For Couples
03 15 09 Course Schedule And Content Communication Keys For Couples03 15 09 Course Schedule And Content Communication Keys For Couples
03 15 09 Course Schedule And Content Communication Keys For Couples
 
Vm3240 va
Vm3240 vaVm3240 va
Vm3240 va
 
569632
569632569632
569632
 
Ms9050 ude
Ms9050 udeMs9050 ude
Ms9050 ude
 
120168 en2
120168 en2120168 en2
120168 en2
 
ORS Poster
ORS PosterORS Poster
ORS Poster
 
Ttest
TtestTtest
Ttest
 
Dh ca-dw171 e
Dh ca-dw171 eDh ca-dw171 e
Dh ca-dw171 e
 
DH: Desafios do Retalho para 2009
DH: Desafios do Retalho para 2009DH: Desafios do Retalho para 2009
DH: Desafios do Retalho para 2009
 
Lbc 395001
Lbc 395001Lbc 395001
Lbc 395001
 
Invent a tool - rubric
Invent a tool - rubricInvent a tool - rubric
Invent a tool - rubric
 

Similar to Hx 40 40-am_40dam_manual_en.pdf

Instruction Manual | EOTech Vudu X 2-12x40 | Optics Trade
Instruction Manual | EOTech Vudu X 2-12x40 | Optics TradeInstruction Manual | EOTech Vudu X 2-12x40 | Optics Trade
Instruction Manual | EOTech Vudu X 2-12x40 | Optics TradeOptics-Trade
 
Honeywell 5898-data-sheet
Honeywell 5898-data-sheetHoneywell 5898-data-sheet
Honeywell 5898-data-sheetAlarm Grid
 
total station spectra Focus 30, 2" robotic,
total station spectra Focus 30, 2" robotic, total station spectra Focus 30, 2" robotic,
total station spectra Focus 30, 2" robotic, irfan buana88
 
Brosur focus 35
Brosur focus 35Brosur focus 35
Brosur focus 35Budi anto
 
lsm9506mdinuefufbusfbffffffffggghhhhh.pdf
lsm9506mdinuefufbusfbffffffffggghhhhh.pdflsm9506mdinuefufbusfbffffffffggghhhhh.pdf
lsm9506mdinuefufbusfbffffffffggghhhhh.pdfRidwanAli30
 
EB-230 Data Sheet V1 2
EB-230 Data Sheet V1 2EB-230 Data Sheet V1 2
EB-230 Data Sheet V1 2esthershiang88
 
1832 1932 1942 operator's manual s 2 3-09 radar furuno
1832 1932 1942 operator's manual s  2 3-09 radar furuno1832 1932 1942 operator's manual s  2 3-09 radar furuno
1832 1932 1942 operator's manual s 2 3-09 radar furunoRicardo Mendes
 
Manual - 0ffe6f4b e71c-4912-bc17-a3133bd5c075
Manual - 0ffe6f4b e71c-4912-bc17-a3133bd5c075Manual - 0ffe6f4b e71c-4912-bc17-a3133bd5c075
Manual - 0ffe6f4b e71c-4912-bc17-a3133bd5c075Anil Takalikar
 
Modicon TM3 - Safety Modules, Hardware Guide.pdf
Modicon TM3 - Safety Modules, Hardware Guide.pdfModicon TM3 - Safety Modules, Hardware Guide.pdf
Modicon TM3 - Safety Modules, Hardware Guide.pdfAnooMehmood
 
John deere js series 21 inch walk-behind mower service repair manual
John deere js series 21 inch walk-behind mower service repair manualJohn deere js series 21 inch walk-behind mower service repair manual
John deere js series 21 inch walk-behind mower service repair manualfhsjekkdkem
 
John deere js series 21 inch walk-behind mower service repair manual
John deere js series 21 inch walk-behind mower service repair manualJohn deere js series 21 inch walk-behind mower service repair manual
John deere js series 21 inch walk-behind mower service repair manualfjskedsxmmem
 
John deere js series 21 inch walk-behind mower service repair manual
John deere js series 21 inch walk-behind mower service repair manualJohn deere js series 21 inch walk-behind mower service repair manual
John deere js series 21 inch walk-behind mower service repair manualdidkkskddm
 

Similar to Hx 40 40-am_40dam_manual_en.pdf (20)

Instruction Manual | EOTech Vudu X 2-12x40 | Optics Trade
Instruction Manual | EOTech Vudu X 2-12x40 | Optics TradeInstruction Manual | EOTech Vudu X 2-12x40 | Optics Trade
Instruction Manual | EOTech Vudu X 2-12x40 | Optics Trade
 
Honeywell 5898-data-sheet
Honeywell 5898-data-sheetHoneywell 5898-data-sheet
Honeywell 5898-data-sheet
 
total station spectra Focus 30, 2" robotic,
total station spectra Focus 30, 2" robotic, total station spectra Focus 30, 2" robotic,
total station spectra Focus 30, 2" robotic,
 
3-Axis Orientation Motion MMAC7660FC
3-Axis Orientation Motion MMAC7660FC3-Axis Orientation Motion MMAC7660FC
3-Axis Orientation Motion MMAC7660FC
 
1912792.pdf
1912792.pdf1912792.pdf
1912792.pdf
 
M 1623 om-eng_ 35100_h
M 1623 om-eng_ 35100_hM 1623 om-eng_ 35100_h
M 1623 om-eng_ 35100_h
 
M 1623 om-eng_35100_h
M 1623 om-eng_35100_hM 1623 om-eng_35100_h
M 1623 om-eng_35100_h
 
Brosur focus 35
Brosur focus 35Brosur focus 35
Brosur focus 35
 
Sl1200 mk5
Sl1200 mk5Sl1200 mk5
Sl1200 mk5
 
lsm9506mdinuefufbusfbffffffffggghhhhh.pdf
lsm9506mdinuefufbusfbffffffffggghhhhh.pdflsm9506mdinuefufbusfbffffffffggghhhhh.pdf
lsm9506mdinuefufbusfbffffffffggghhhhh.pdf
 
F199
F199F199
F199
 
EB-230 Data Sheet V1 2
EB-230 Data Sheet V1 2EB-230 Data Sheet V1 2
EB-230 Data Sheet V1 2
 
Equipo de sonido lg lm u5050 u4050 a
Equipo de sonido lg lm u5050 u4050 aEquipo de sonido lg lm u5050 u4050 a
Equipo de sonido lg lm u5050 u4050 a
 
Equipo de sonido lg lm u5050 u4050 a
Equipo de sonido lg lm u5050 u4050 aEquipo de sonido lg lm u5050 u4050 a
Equipo de sonido lg lm u5050 u4050 a
 
1832 1932 1942 operator's manual s 2 3-09 radar furuno
1832 1932 1942 operator's manual s  2 3-09 radar furuno1832 1932 1942 operator's manual s  2 3-09 radar furuno
1832 1932 1942 operator's manual s 2 3-09 radar furuno
 
Manual - 0ffe6f4b e71c-4912-bc17-a3133bd5c075
Manual - 0ffe6f4b e71c-4912-bc17-a3133bd5c075Manual - 0ffe6f4b e71c-4912-bc17-a3133bd5c075
Manual - 0ffe6f4b e71c-4912-bc17-a3133bd5c075
 
Modicon TM3 - Safety Modules, Hardware Guide.pdf
Modicon TM3 - Safety Modules, Hardware Guide.pdfModicon TM3 - Safety Modules, Hardware Guide.pdf
Modicon TM3 - Safety Modules, Hardware Guide.pdf
 
John deere js series 21 inch walk-behind mower service repair manual
John deere js series 21 inch walk-behind mower service repair manualJohn deere js series 21 inch walk-behind mower service repair manual
John deere js series 21 inch walk-behind mower service repair manual
 
John deere js series 21 inch walk-behind mower service repair manual
John deere js series 21 inch walk-behind mower service repair manualJohn deere js series 21 inch walk-behind mower service repair manual
John deere js series 21 inch walk-behind mower service repair manual
 
John deere js series 21 inch walk-behind mower service repair manual
John deere js series 21 inch walk-behind mower service repair manualJohn deere js series 21 inch walk-behind mower service repair manual
John deere js series 21 inch walk-behind mower service repair manual
 

More from sanzen enterprises (20)

Odyssey 3
Odyssey 3Odyssey 3
Odyssey 3
 
Vm3240va ce cb1e
Vm3240va ce cb1eVm3240va ce cb1e
Vm3240va ce cb1e
 
Vm 3240 e
Vm 3240 eVm 3240 e
Vm 3240 e
 
Sv200ma mi1e
Sv200ma mi1eSv200ma mi1e
Sv200ma mi1e
 
Sc610 cs1e
Sc610 cs1eSc610 cs1e
Sc610 cs1e
 
Sc610 cs1e
Sc610 cs1eSc610 cs1e
Sc610 cs1e
 
Cs154 cs1e
Cs154 cs1eCs154 cs1e
Cs154 cs1e
 
Bs678 cs1e tei rev1
Bs678 cs1e tei rev1Bs678 cs1e tei rev1
Bs678 cs1e tei rev1
 
Bs633a data sheet
Bs633a data sheetBs633a data sheet
Bs633a data sheet
 
Data sheet en_us_1902186891
Data sheet en_us_1902186891Data sheet en_us_1902186891
Data sheet en_us_1902186891
 
Data sheet en_us_1902186891
Data sheet en_us_1902186891Data sheet en_us_1902186891
Data sheet en_us_1902186891
 
Data sheet en_us_1911721995
Data sheet en_us_1911721995Data sheet en_us_1911721995
Data sheet en_us_1911721995
 
La1 uw24 x column loudspeakers
La1 uw24 x column loudspeakersLa1 uw24 x column loudspeakers
La1 uw24 x column loudspeakers
 
Bgt 4139 ts
Bgt 4139 tsBgt 4139 ts
Bgt 4139 ts
 
Bgt 5504 a
Bgt 5504 aBgt 5504 a
Bgt 5504 a
 
Bgt 5140 a
Bgt 5140 aBgt 5140 a
Bgt 5140 a
 
Bgt 9120 ts
Bgt 9120 tsBgt 9120 ts
Bgt 9120 ts
 
Bgt 9119 as
Bgt 9119 asBgt 9119 as
Bgt 9119 as
 
Bgt 720 tos
Bgt 720 tosBgt 720 tos
Bgt 720 tos
 
Bgt 5221 as
Bgt 5221 asBgt 5221 as
Bgt 5221 as
 

Hx 40 40-am_40dam_manual_en.pdf

  • 1. NO.59-1501-3 INSTALLATION INSTRUCTIONS High Mount Outdoor Detector N219 HX-40/40AM/ 40DAM CONTENTS 1 INSTALLATION PRECAUTIONS ............2 HX-40 2 PIRs standard model 1-1 BEFORE INSTALLATION ................2 HX-40AM HX-40 with anti-masking 1-2 PARTS IDENTIFICATION ................3 HX-40DAM HX-40AM with micro-wave 1-3 KNOCKOUTS ..................................4 • 3.0 m high mount detection area (12.0 m) 1-4 DETECTION AREA..........................5 1-5 DETERMINATION OF PIR • Unique pyro element DETECTION LENGTH ....................5 2 INSTALLATION.......................................6 • Intelligent AND logic 2-1 MOUNTING WITH BRACKET .........6 • Dual signal processing logic 2-2 ADJUSTING THE VERTICAL ANGLE.............................................8 • Vegetation sway analysis logic 2-3 MOUNTING WITHOUT BRACKET ........................................9 • Ideal detection area setting 2-4 WIRING .........................................10 2-5 WALL TAMPER (OPTION) ............ 11 • Digital anti-masking (AM/DAM model only) 3 WALK TEST..........................................12 • Microwave range selector (DAM model only) 4 SETTING ..............................................13 5 AREA ADJUSTMENT ...........................16 6 LED INDICATION .................................17 7 SPECIFICATIONS ................................18 7-1 SPECIFICATIONS .........................18 7-2 DIMENSIONS ................................19 -1- HX-40DAM_EN.indd 1 2010/06/24 14:11:55
  • 2. 1 INSTALLATION PRECAUTIONS 1-1 BEFORE INSTALLATION Failure to follow the instructions provided with this indication and improper Warning handling may cause death or serious injury. Failure to follow the instructions provided with this indication and improper Caution handling may cause injury and/or property damage. The check mark indicates recommendation. The nix sign indicates prohibition. Warning Warning Caution Do not repair or modify product Keep product away from water Mount the unit securely Mounting height Keep the detector parallel to the ground. 2.5 m – 3.0 m (8'2" – 9'10") Parallel Tilt Consider the direction a person is approaching from, as well as the detection area. Install the detector in a place where it is free from false alarm factors. For example: • Sunlight and reflection • Heat source • Objects moving in the wind -2- HX-40DAM_EN.indd 2 2010/06/24 14:11:57
  • 3. HX-40 HX-40AM -Precautions for installing two or more sensors HX-40DAM Do not install two or more HX-40DAM’s units side-by-side or face-to-face. Instead, install them back-to-back. If mounting on the same wall, be sure they are at least 1.0 m (3'3") apart from each other. 1.0 m (3'3") or more Less than 1.0 m (3'3") 1-2 PARTS IDENTIFICATION Bracket base Base Screw (3 × 10 mm) Terminals Main unit Hood PIR sensor (Do not touch) Bracket Anti-masking infrared LED (HX-40AM/DAM only) Shaft cover Lock screw* (M4 × 35 mm) Screw (4 × 20 mm) Microwave unit (HX-40DAM only) (Do not touch) Lens LED indicator Cover Lock screw Area masking seal Screw kit For joint For wall mounting For hood Screw (4 × 20 mm) Screw (4 × 20 mm) Screw (3 × 10 mm) *Lock screw attached on bracket base -3- HX-40DAM_EN.indd 3 2010/06/24 14:11:58
  • 4. 1-3 KNOCKOUTS Main unit Bracket Wiring Hole Wiring knockout (Off-the-shelf) magnet switch installation position Wiring Hole Wiring sponge pad Do not touch For wall For switch Up-Down fastening box fastening lock screw For bracket For wall fastening/bracket fastening Adjustment screw For main unit fastening Up-Down lock screw (installation pitch 83.5 mm (3.29")) -4- HX-40DAM_EN.indd 4 2010/06/24 14:11:58
  • 5. 1-4 DETECTION AREA Side view Top view (Mounting height: 3.0 m (9'10")) 0' 10' 20' 30' 40' 40' 0' 10' 20' 30' 40' (ft.) (ft.) (ft.) (m) 2 4 6 8 10 12 12.0 m (ft.) 8 (m) MW 10' PIR 20' 6 3.0 m 40° 5' 30° 0' 4 20° 10' 2 (Mounting height: 2.5 m (8'2")) 10° 85° 0' 10' 20' 30' 40' (ft.) 0' 0 12.0 m 2 (ft.) 10' MW 10' PIR PIR 4 2.5 m 5' 0' 20' 6 MW • Vertical angle: 1 click (2.5°) upward 8 (Refer to “caution” in 2-2). (ft.) (m) 1-5 DETERMINATION OF PIR DETECTION LENGTH To adjust the detection length, apply the masking seals to the back of the lens according to the required detection length. Three types of masking seals are provided. Combine them according to the detection length required. Apply masking seal directly on the back side of the lens. 9.0 m (29'6") 5.5 m (18'1") 4.0 m (13'1") 3.0 m (9'10") 3.0 m (9'10") 3.0 m (9'10") 1 1 1 3 2 2 For microwave detection setting please refer to “4 SETTING”. -5- HX-40DAM_EN.indd 5 2010/06/24 14:11:59
  • 6. 2 INSTALLATION Use the bracket for normal installation. The unit may be mounted directly on the wall, without the bracket, only if the following three conditions are not; • The mounting height 3.0 m (9'10"). • Horizontal direction adjustment is unnecessary. • The ground is level. 2-1 MOUNTING WITH BRACKET Using the bracket makes it possible to adjust the unit horizontally by ±90°. In cases where the ground is uneven and/or not parallel with the base of the unit, it is possible to adjust the unit vertically by ±20°. Caution>> Do not change the detection length with bracket. Use the masking seal to adjust the detection length. 90° 90° 20° 20° Remove the Up-Down lock screw. Push the shaft cover clip straightforwardly with 1 2 your thumb. In case the clip is stuck, use a suitable tool. e.g. back side of a screw driver. Shaft cover Shaft cover clip Loosen the adjustment screw two turns. Tilt the bracket about 45° and pass 3 4 through the wire. In Adjustment screw Out Caution>> Do not loosen the screw too much. It may disassemble. -6- HX-40DAM_EN.indd 6 2010/06/24 14:11:59
  • 7. Determine the horizontal direction (left or Open the wiring knockout. 5 right) of the detector before installing the 6 bracket on the wall. To the right To the left Wiring knockout Open the Up-Down lock screw knockout Tighten screws 1 and 2, adjust the bracket 7 for connecting the bracket. 8 angle (refer to 2-2), then tighten screw 3. Perform an area check. If re-adjustment is required, loosen screw 3 and change the bracket angle. After the adjustment is complete, tighten screw 3 again. In Knockout with 4 × 20 tapping screw (screwkit) Wiring hole Wiring sponge pad 14 × 20 screw Out 34 × 35 Up-Down lock screw 24 × 20 screw Tighten the adjustment screw clockwise. 9 10 Wireandthe terminal and install the main unit to lens on the base. Adjustment screw Install the shaft cover into place. 11 -7- HX-40DAM_EN.indd 7 2010/06/24 14:12:00
  • 8. 2-2 ADJUSTING THE VERTICAL ANGLE For best performance, install detector parallel to the ground. Decide the detection length. If you choose 9.0 m/5.5 m/4.0 m, mask the unnecessary lens with masking seals. Refer to the 1-5 for the details. 12.0 m (40') Perform the walk test to check 3.0 m (9'10") if detector is parallel to the ground. * This is the case to have 12 m detection length. If the detection length is shorter than the designated one (refer to page 5), change If the detection length is the detector angle upward. equal to the designated one, adjustments have If the detection length is been completed. longer than the designated one (refer to page 5), change the detector angle downward. Caution>> If the base of the unit is already parallel to the ground, • Do not change the detection length by tilting the unit up or down. Detection length should be adjusted with masking seal. Refer to 1-5 and 2-1 for the details. 0° Example (the ground is level) 2 clicks (5°) 4 clicks (10°) 0° is the right setting for 3.0 m (9'10") height installation. Adjust 1 click (2.5° upward) for 2.5 m (8'2") height installation. -8- HX-40DAM_EN.indd 8 2010/06/24 14:12:01
  • 9. 2-3 MOUNTING WITHOUT BRACKET Open the wiring knockout with suitable Pull the wire through the base knockout. 1 tool e.g. screwdriver. 2 In Out Wiring sponge pad Fasten the base to the wall. Install main unit after wiring to the 3 4 terminal. -9- HX-40DAM_EN.indd 9 2010/06/24 14:12:01
  • 10. 2-4 WIRING Power wires should not exceed the following lengths. HX-40 HX-40AM HX-40DAM WIRE GAUGE 12 V 14 V 12 V 14 V 12 V 14 V 160 m 360 m 140 m 310 m 120 m 250 m AWG22 (0.33 mm ) 2 (520') (1,180') (460') (1,020') (390') (820') 260 m 560 m 230 m 490 m 180 m 390 m AWG20 (0.52 mm ) 2 (850') (1,840') (750') (1,610') (590') (1,280') 410 m 900 m 360 m 780 m 290 m 630 m AWG18 (0.83 mm2) (1,350') (2,950') (1,180') (2,560') (950') (2,070') POWER INPUT (+) (9.5 - 18VDC) POWER INPUT (-) (9.5 - 18VDC) ALARM OUTPUT (COM) ALARM OUTPUT (N.O.) ALARM OUTPUT (N.C.) TROUBLE OUTPUT SPARE (Non short) TAMPER OUTPUT AUX INPUT (N.C.) *1 (N.C.) (N.C.) HX-40AM HX-40DAM TAMPER AUX TROUBLE N.O. COM N.C. – + SP SP INPUT OUTPUT ALARM POWER (N.C.) (N.C.) T.O.(N.C.) 9.5-18VDC HX-40 TAMPER AUX N.O. COM N.C. – + SP SP INPUT ALARM POWER (N.C.) (N.C.) 9.5-18VDC *1: TAMPER terminals to be connected to a 24 hour supervisory loop. - 10 - HX-40DAM_EN.indd 10 2010/06/24 14:12:01
  • 11. 2-5 WALL TAMPER (OPTION) Universal magnet switch may be mounted as a wall tamper. Installation space for universal magnet switch is provided on the back of the main unit and the bracket. Maximum size of an applicable universal magnet switch: D 9 mm (0.35'') × W 40 mm (1.57'') × H 9 mm (0.35''). Universal magnet switch on the market assist is not included. Main unit Bracket Wiring Hole Magnet switch (Bracket side) Magnet switch (Wall side) installation position Magnet switch (Wall side) installation position installation position Magnet switch (Base side) installation position -Installation Install the universal magnet switch (wall Open the wiring knockout with suitable 1 side) to the wall. To determine the install 2 tool e.g. screwdriver. position, use the “Install position template” provided on the inside cover of the product package. Install the other portion of the universal magnet switch to the back of the main unit or the 3 bracket. Pull the wiring through the knockouts. When not using the bracket 1 Fix 2 In 4 Wiring sponge pad Out 3 - 11 - HX-40DAM_EN.indd 11 2010/06/24 14:12:02
  • 12. When using the bracket 1 Fix In 4 In 2 Tilt the bracket about 45° and pass through the wire. 6 In 3 Wiring 5 Out Out sponge pad Magnet switch Install the bracket and the main unit to Connect the universal magnet switch wiring 4 the wall surface. 5 to the tamper terminal of the main unit. 3 WALK TEST Set the DIP switch 1 (LED ON/OFF) to Check that the detector detects an 1 “ON”. 2 object in the intended detection area. The installation has been successful if the LED lights for two seconds after a person walks into the detection area. Detected Not detected Note>> The switch is set “ON” by factory default. Note>> For the walk test, move more than 1.0 m (3'3") away from the detector. If the LED indication is not required at all 3 times, set the DIP switch 1 (LED ON/ OFF) to “OFF”. - 12 - HX-40DAM_EN.indd 12 2010/06/24 14:12:02
  • 13. 4 SETTING Do not touch DIP switch MW range 1. LED ON/OFF selector 2. PIR IMMUNITY 3. AUX INPUT MW sensitivity 4. TROUBLE OUTPUT adjustment 5. MICROWAVE IMMUNITY 6. (Reserved) HI STD Anti masking OFF sensitibity selector Do not touch PIR sensitivity selector HX-40 HX-40AM -LED ON/OFF DIP switch 1 HX-40DAM POSITION FUNCTION ON The LED lights when someone is (Factory detected. default) The LED does not light even if OFF someone is detected. OFF ON HX-40 HX-40AM -PIR IMMUNITY DIP switch 2 HX-40DAM POSITION FUNCTION STD (Factory PIR IMMUNITY logic is not activated. default) PIR IMMUNITY logic is activated. Use IMMUNITY this under harsh environment (e.g. small animal). STD IMMUNITY - 13 - HX-40DAM_EN.indd 13 2010/06/24 14:12:03
  • 14. HX-40 HX-40AM -AUX INPUT DIP switch 3 HX-40DAM By connecting a satellite unit (another warning sensor), you can extend the detection area and correct false alarms. As a satellite unit, you can use any general no-voltage contact output (NC) warning sensor, including the following. <Infrared (AIR) sensors, thermal line (PIR) sensors, universal magnet switches, etc.> POSITION FUNCTION AND When both the main unit and the satellite detect someone, the (Factory alarm is output. default) Set to this when not connecting a satellite unit. When either the main unit or the satellite detects someone, OR the alarm is output. AND OR Notes>> • The alarm does not output unless both the main unit and the satellite detect someone within 60 sec. • If the OR mode is selected without a satellite unit connected, the alarm is generated continuously. HX-40 HX-40AM -TROUBLE OUTPUT DIP switch 4 HX-40DAM Trouble output is used for anti-masking signal. When an object is placed close to the lens surface, for a period of more than 180 sec., the IR Anti-Masking circuit is activated and generates a trouble signal. POSITION FUNCTION ON Anti-masking signal is output from TROUBLE OUTPUT (Factory terminal. default) Anti-masking signal is output from both TROUBLE and OFF ALARM OUTPUT terminal. Note>> OFF ON Use this when not wiring a detected trouble input terminal on the control panel. HX-40 HX-40AM -MICROWAVE IMMUNITY DIP switch 5 HX-40DAM POSITION FUNCTION STD (Factory MICRO WAVE IMMUNITY logic is not activated. default) MICRO WAVE IMMUNITY logic is activated. Use this IMMUNITY under harsh environment (e.g. vegetation sway). STD IMMUNITY - 14 - HX-40DAM_EN.indd 14 2010/06/24 14:12:03
  • 15. RANGE SELECTOR/ HX-40 SENSITIVITY HX-40AM -MW RANGE SELECTOR/MW SENSITIVITY ADJUSTMENT ADJUSTMENT HX-40DAM DETECTION AREA MW RANGE MW SENSITIVITY PIR AREA SETTING (SIDE VIEW) SELECTOR ADJUSTMENT LONG MID 12.0 m M (40') 0 SHORT PIR LONG L H MW Factory default 1 SHORT HIGH 9.0 m M SHORT (29'6'') 0 PIR L H MW LONG 1 SHORT MID 5.5 m M (18'1'') 2 SHORT 0 PIR MW LONG L H 1 SHORT LOW 4.0 m 3 M (13'1'') 2 0 SHORT PIR MW L H LONG - 15 - HX-40DAM_EN.indd 15 2010/06/24 14:12:03
  • 16. HX-40 PIR HX-40AM -PIR SENSITIVITY SENSITIVITY SELECTOR HX-40DAM POSITION FUNCTION HIGH HIGH High sensitivity MIDDLE MIDDLE Middle sensitivity (Factory default) LOW LOW Low sensitivity HX-40 ANTI-MASKING HX-40AM -ANTI-MASKING SENSITIVITY SENSITIVITY SELECTOR HX-40DAM POSITION FUNCTION HIGH High sensitivity HIGH STD Standard sensitivity (Factory default) STD OFF Disabled OFF Caution>> When closing the cover, do not leave any object within 1 meter from the unit. 5 AREA ADJUSTMENT -DETECTION LENGTH ADJUSTMENT To limit the detection length, apply the appropriate masking seal. Note that there are three different types of seal. 9.0 m (29'6") 5.5 m (18'1") 4.0 m (13'1") 3.0 m (9'10") 3.0 m (9'10") 3.0 m (9'10") 1 1 1 3 2 2 -AREA MASKING Pasting on example for 1 masking No. 5 and No. 6 2 3 1 2 Area masking seal 3 4 4 5 0 5 56 6 7 8 6 9 7 8 9 - 16 - HX-40DAM_EN.indd 16 2010/06/24 14:12:04
  • 17. 6 LED INDICATION Red Yellow Blink Light OFF (HX-40DAM only) Green (HX-40DAM only) -HX-40/40AM DETECTOR CONDITION LED INDICATOR (RED ONLY) Warm-up Blinks for approx. 60 sec. Alarm Lights for 2 sec. Anti-Masking booting (Anti-Masking start up) Blinks 2 times and goes off for 5 sec. and then repeats for 180 sec. Trouble output Masking detection Blinks 3 times and goes off for 3 sec. and then repeats. -HX-40DAM DETECTOR CONDITION LED INDICATOR Warm-up Blinks for approx. 60 sec. Alarm Red lights for 2 sec. PIR detection Green lights for 2 sec. MW detection Yellow lights for 2 sec. Anti-Masking booting (Anti-Masking Green and Red blink 2 times simultaneously and go off for start up) Trouble 5 sec. This sequence is repeated for 180 sec. output Masking detection Green and Red blink 3 times simultaneously and go off for 3 sec. This sequence is repeated. - 17 - HX-40DAM_EN.indd 17 2010/06/24 14:12:04
  • 18. 7 SPECIFICATIONS 7-1 SPECIFICATIONS Model HX-40 HX-40AM HX-40DAM Detection method Passive infrared Passive infrared & Microwave PIR Coverage 12.0 m (40') 85° wide / 94 zones PIR distance limit 4.0 m, 5.5 m, 9.0 m (13'1", 18'1", 29'6") Detectable speed 0.3 m/s – 1.5 m/s (1'/s – 4'11"/s) Sensitivity 2.0°C (3.6°F) at 0.6 m/s Power input 9.5 – 18 V DC 35 mA (max.) 40 mA (max.) 50 mA (max.) Current draw at 12 V DC at 12 V DC at 12 V DC Alarm period 2.0 ±1 sec. Warm-up period Approx. 60 sec. (LED blinks) Alarm output Form C 28 V DC 0.2 A (max.) Tamper output N.C. 28 V DC, 0.1 A (max.) N.C. open when cover removed. Trouble output – N.C. 28 V DC, 0.1 A (max.) Aux input N.C. 28 V DC, 0.1 A (max.) Red: Warm-up, Alarm, Trouble Red: Warm-up, Red: Warm-up, Green: LED indicator Alarm, Alarm Warm-up, PIR detect, Trouble Trouble Yellow: Warm-up, MW detect RF interference No alarm 10 V/m Operating temperature -20 – +60°C (-4 – +140°F) Environment humidity 95% max. Weatherproof IP55 Mounting Wall Mounting height 2.5 – 3.0 m (8'2" – 9'10") Bracket adjust angle Vertical: ±20° Horizontal: ±95° Weight 600 g (21.2 oz.) 700 g (24.7 oz.) Accessories Bracket, Hood, Area masking seal, Screw (3 × 10 mm) × 2, Screw (4 × 20 mm) × 4 *Specifications and designs are subject to change without prior notice. - 18 - HX-40DAM_EN.indd 18 2010/06/24 14:12:05
  • 19. 7-2 DIMENSIONS Using bracket and hood Without bracket and hood 266 (10.47) 99 (3.90) 148 (5.83) 92 (3.62) 197.5 (7.78) 205 (8.07) Unit: mm (inch) Unit: mm (inch) - 19 - HX-40DAM_EN.indd 19 2010/06/24 14:12:05
  • 20. NOTE The following statement will be provided with the equipment as required by Article 6.3 of the R&TTE Directive, 1999/5/EC. The Optex HX series are in conformity with all essential requirements of the R&TTE Directive (1999/5/EC). This equipment has been assessed to the following standards: EN 300 440-1: 2009 EN 50130-4: 2004 including amendment 2: 2003 EN 60950-1: 2006+A11: 2009 This product is marked with which signifies conformity with Class II product requirements specified in the R&TTE Directive. The following table indicates the areas of intended use of the equipment and any known restrictions. For countries not included in this list, please consult the responsible Spectrum Management Agency. Country of intended use Restrictions Country of intended use Restrictions Austria 9.900GHz Luxembourg 10.525GHz Belgium 10.525GHz The Netherlands 10.525GHz Denmark 10.525GHz Spain 10.525GHz Finland 9.900GHz Sweden 10.525GHz France 10.587GHz United Kingdom 10.587GHz Greece 10.525GHz Other non-EU: Iceland 10.525GHz Ireland 10.587GHz Norway 10.525GHz Italy 10.525GHz Switzerland 10.525GHz FCC ID : DC9 OPMW IC : 4012A-OPMW This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The HX-40 series is only a part of a complete system, therefore we cannot accept complete responsibility for any damages or other consequences resulting from an intrusion. OPTEX CO., LTD. (JAPAN) OPTEX INCORPORATED (USA) OPTEX SECURITY Sp. z o. o. (POLAND) TEL:+1-909-993-5770 TEL:+48-22-598-06-55 (ISO 9001 Certified) Tech:(800)966-7839 URL:http://www.optex.com.pl/ (ISO 14001 Certified) URL:http://www.optexamerica.com/ 5-8-12 Ogoto Otsu Shiga 520-0101 OPTEX (EUROPE) LTD. (UK) OPTEX KOREA CO., LTD. (KOREA) JAPAN TEL:+44-1628-631000 TEL:+82-2-719-5971 URL:http://www.optexeurope.com/ URL:http://www.optexkorea.com/ TEL:+81-77-579-8670 FAX:+81-77-579-8190 URL:http://www.optex.co.jp/e/ OPTEX SECURITY SAS (FRANCE) OPTEX (DONGGUAN) CO., LTD. TEL:+33-437-55-50-50 SHENZHEN OFFICE (CHINA) URL:http://www.optex-security.com/ TEL:+86-755-33302950 URL:http://www.optexchina.com/ - 20 - HX-40DAM_EN.indd 20 2010/06/24 14:12:05