SHORT RANGE PHOTOELECTRIC DETECTOR


                                                                                                                                                                                                                                                               AX-70 / 130 / 200TN
   SPECIFICATIONS

  Model                                                  AX-70TN                             AX-130TN               AX-200TN                        AX-100TF                         AX-200TF

  Detection method                                                                                  Infrared beam interruption detection                                                                                                                                               (STANDARD MODEL)


                                                                                                                                                                                                                                                                  AX-100 / 200TF
  Maximum detection range                               20m (70ft.)                   40m (130ft.)                 60m (200ft.)                    30m (100ft.)                    60m (200ft.)
  Maximum arrival range                                200m (700ft.)            400m (1300ft.)                   600m (2000ft.)                  300m (1000ft.)                  600m (2000ft.)
  Interruption period                                                                         Selectable between 50, 100, 250, and 500m sec.
                                                                                                                                                                                                                                                                                       (ENHANCED MODEL)
  Selectable beam frequency                                                                                                                                          4 channel
  Power supply                                                                                                   10.5 - 28V DC
  Current consumption (transmitter + receiver)         38mA (max.)                  41mA (max.)                   45mA (max.)                     44mA (max.)                      48mA (max.)
  Alarm period                                                                                                2sec. (±1) nominal
  Alarm output                                                           N.C. 28V DC, 0.2A (max.)                                                   N.C./N.O. 28V DC, 0.2A (max.)
  D.Q. output                                                                                                                                           N.C. 28V DC, 0.2A (max.)
  Tamper switch                                                                         Opens when cover is removed at 28V DC, 0.2A max.
                                                                                         -35°C to +60°C (-31°F to +140°F)
  Operating temperature
                                                                    Use the optional heating unit (HU-3) in conditions of -25°C (-13°F) or below.
  Operating humidity                                                                                                95% max.
  Alignment angle                                                                                       ± 90° Horizontal, ± 5° Vertical
  Mounting                                                                                                 Wall and pole mounting
  Weight (transmitter + receiver)                                               650g (22.9oz.)                                                                   700g (24.7oz.)
  Housing protection (EN 00529)                                                                                         IP65
*Specifications and design are subject to change without prior notice.
 NOTE: These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or
 other consequences resulting from an intrusion. These products conform to the EMC Directive 89/336 ECC.



   DIMENSIONS                                                                                           OPTIONS

                                                                                                                                                  ■ HU-3 : Heating Unit
                                                                                                                                                        Heating unit for severe low
                                                                                                                                                        temperature conditions
                                                                                                                                                        24V DC/AC, 420mA max.
                                                                                36 (1.4)




                                                                                                                                                        1 set (2 units)




                                                                                                                                                  ■ BC-3 : Back Cover
                                                                                                                                                        Can be used to cover
                                                                                                                                                        mounting pole.
                                                                                83.5 (3.3)
    170 (6.7)




                                                                                                                                                        1 set (2 units)




                                                                                                                                                  ■ PSC-3 : Pole Side Cover
                                                                                                                                                        Cover for installing
                                                                                                                                                        2 units to 1 pole.
                65 (2.6)         69.5 (2.7)                                                                                                             1 set (2 units)




                                                  Dimensions : mm (inches)




                                                                                                           OPTEX CO., LTD.
                                                                                                           (ISO 9001 Certified by LRQA / ISO14001 Certified by JET)
                                                                                                                                                                                                            The Best Short Range Photoelectric Detector
                                                                                                           5-8-12 Ogoto, Otsu, Shiga, 520-0101 Japan
                                                                                                           TEL +81(0)77 579 8670 FAX +81(0)77 579 8190           http://www.optex.co.jp/e                   AX-TN/TF series is a compact photoelectric detector with "the IP65 high durability", and
                                                                                                           OPTEX INCORPORATED (USA)                              http://www.optexamerica.com
                                                                                                           OPTEX (EUROPE) LTD. (UK)                              http://www.optexeurope.com                 "stable detection performance".
                                                                                                           OPTEX SECURITY SAS (FRANCE)                           http://www.optex-security.com
                                                                                                           OPTEX KOREA CO., LTD. (KOREA)                         http://www.optexkorea.com                  These features reduce false alarms drastically caused by outdoor severe environmental changes and
                                                                                                           OPTEX SECURITY Sp. z o.o. (POLAND)
                                                                                                           OPTEX(DONGGUAN) CO., LTD.                             http://www.optexchina.com                  provide a wide range of applications.
                                                                                                           Shenzhen office(CHINA)
                                                                                                           “Take Care of the Environment” This catalogue uses recycled paper      No. 75107-01-14931-0703
SHORT RANGE PHOTOELECTRIC DETECTOR

                                                                                                                                                                                                                                                             AX-70 / 130 / 200TN (STANDARD MODEL)
The best short range photoelectric                                                                                                                                                                                                                           AX-100 / 200TF (ENHANCED MODEL)

                                                                                                                     □ IP65 structure with high sealing rubber packing                                        □ Anti-frost hood cover

detector from OPTEX                                                                                                     Rubber packing is used for all
                                                                                                                        conceivable points where water or
                                                                                                                        dust may penetrate, such as wiring
                                                                                                                        holes, wire ports and the outer
                                                                                                                                                                                                                 A hood is installed to prevent frost forming on lower beams. It also makes
                                                                                                                                                                                                                 the maintenance easy because the surface of the cover is flat.

                                                                                                                                                                                                              □ Lightning protection
                                                                                                                        chassis. Prevention from dust, bugs                                                      An improved Electro-Magnetic Interference surge absorber and high
                                                                                                                        and water delivers performance with                                                      surge resistive relay has been installed to protect from lightning surges
                                                                                                                        higher reliability against false alarms                                                  and maintain stable operation.
                                                                                                                        and breakdowns.
                                                                                                                                                                                                    Rubber       Lightning Protection Level
                                                                                                                                                                                                    packing
                                                                                                                        IP65
                                                                                                                                                                                                                                                               Will remain stable against over
                                                                                                                                 Waterproof.                                                        Wiring              Conventional                           14kV of lightning surge.
                                                                                                                                 Protected against water jets from                                  hole                Detector
                                                                                                                                 any direction

                                                                                                                                 Dust-tight.
                                                                                                                                                                                                                        AX Series
                                                                                                                                 No ingress of dust.
                                                                                                                                                                                                                       0 2             4        6        8           10         12          14
                                                                                                                                 International Protection Code.                                                                            Lightning Surge Voltage Level                  (kV)
                                                                                                                                 It shows the degrees of protection
                                                                                                                                 provided by enclosures.
                                                                                                                                                                                                              □ Easy angle adjustment
                                                                                                                                                                                                                 It allows the installer to finely adjust the beam easily.
                                                                                                                        5 degrees of water conditions were                                                       [ Horizontally ±90° with hand ]
                                                                                                                        used to evaluate the protection                                                          [ Vertically ±5° with screwdriver ]
                                                                                                                        against water
                                                                                                                        Tests were conducted using a water                                                    □ High grade spherical lens
                                                                                                                        jet stream that applied 12.5                                                             The high grade spherical lens creates more sharply defined & precise
                                                                                                                        liters/min of water at a distance of
                                                                                                                                                                                                                 infrared beams compared to ordinary fresnel lenses.
                                                                                                                        approximately 3 meters for roughly 3
                                                                                                                        minutes. This test was directly
                                                                                                                        applied to the chassis of the AX-TN                                                   □ A.G.C. (Automatic Gain Control) Circuit
                                                                                                                        and TF series.                                                                           A.G.C. circuit continually monitors for gradual changes in the signal's strength
                                                                                                                                                                                                                 caused by changing weather conditions. It adjusts the sensitivity accordingly
                                                                                                                                                                                                                 to maintain the proper signal level for the current environmental conditions.
                                                                                                                        The tests resulted with the AX-TN/TF
                                                                                                                        unit undamaged due to the highly                                                      □ 99% beam blocking stability
                                                                                                                        durable IP65 rated structure. It aids
                                                                                                                        in the prevention of water damage to                                                     Enables stable operation with as much as 99% loss of beam energy
                                                                                                                        the unit while keeping the detector                                                      caused by heavy rain, dust storms, fog or snow.
                                                                                                                        operating accurately in outdoor
                                                                                                                        environments.                                                                         □ Adjustable beam interruption period
                                                                                                                                                                                                                 The beam interruption time can be adjusted to fit any application. For
                                                                                                                                                                                                                 example, when protecting a wall or fence, a longer interruption time will
                                                                                                                                                                                                                 catch intruders.



                                                                                                                     AX-100/200TF only
                                                                                                                        □ Selectable beam frequencies                                                         □ 4 step alarm indicator LED for fast & accurate optical alignment
                                                                                                                            The selectable beam frequencies can be used to avoid unwanted                        The alignment condition
                                                                                                                            crosstalk that can occur when using multiple photobeams for long                     is visually displayed on                          LED is "ON"
                                                                                                                            distance or beam stacking applications.                                              the LED. It shows the                             Before alignment.
                                                                                                                                                                                                                 alignment condition by
                                                                                                                            1. Long distance stacking
                                                                                                                                                                                                                 using 4 different process
                                                                                                                                TRANSMITTER       RECEIVER RECEIVER   TRANSMITTER   TRANSMITTER   RECEIVER       to achieve accurate and
                                                                                                                                                                                                                                                        LED is "Fast Flickering"
                                                                                                                                                                                                                 easy alignment before
                                                                                                                                     Ch1          Ch1           Ch1     Ch1              Ch3      Ch3
                                                                                                                                                                                                                 fine tuning.                                 Under the beam alignment.
                                                                                                                                                                                                                                                              LED indication changes by
                                                                                                                                                                                                                                                                beam receiving level.
                                                                                                                            2. Two beam long distance
                                                                                                                                TRANSMITTER       RECEIVER RECEIVER   TRANSMITTER   TRANSMITTER   RECEIVER
                                                                                                                                                                                                                                                        LED is "Slow Flickering"
                                                                                                                                     Ch1          Ch1           Ch1     Ch1              Ch2      Ch2
                                                                                                                                                                                                                                                             Beam energy fromtransmitter is
                                                                                                                                                                                                                                                                  reaching receiver.
                                                                                                                                     Ch3          Ch3           Ch3     Ch3              Ch4      Ch4


                                                                                                                                TRANSMITTER       RECEIVER RECEIVER   TRANSMITTER   TRANSMITTER   RECEIVER
OPTEX succeeded to strengthen the basic performance and ability of photoelectric detector to reduce false alarms                                                                                                                                                  LED is "OFF"

under severe outdoor environments.                                                                                      □ D.Q. Circuit
                                                                                                                                                                                                                                                                  Ready for fine tuning

                                                                                                                            D.Q. circuit (environmental disqualification) sends a trouble signal when

The rubber packing for wiring hole prevents rain, dust, and tiny insects from getting into the unit and the widely          the beam strength is below and acceptable level due to heavy fog, rain,
                                                                                                                            snow or other changes in the installation site. The trouble signal output
                                                                                                                                                                                                                                                               Fine Adjustment
                                                                                                                                                                                                                                                                with voltmeter
designed optical pitch maximizes the detection principle of twin beam.                                                      continues as long as the beam strength is below an acceptable level.

More Related Content

What's hot

What's hot (18)

Cat c82 e
Cat c82 eCat c82 e
Cat c82 e
 
Beam1224
Beam1224Beam1224
Beam1224
 
Tcrt1000
Tcrt1000Tcrt1000
Tcrt1000
 
Ut580 eng
Ut580 engUt580 eng
Ut580 eng
 
Testo 922 datasheet 2012
Testo 922 datasheet 2012Testo 922 datasheet 2012
Testo 922 datasheet 2012
 
GP Batetry GP40AAAM Datenblatt Datasheed
GP Batetry GP40AAAM Datenblatt DatasheedGP Batetry GP40AAAM Datenblatt Datasheed
GP Batetry GP40AAAM Datenblatt Datasheed
 
GPT-3000LN / GPT-3000N
GPT-3000LN / GPT-3000NGPT-3000LN / GPT-3000N
GPT-3000LN / GPT-3000N
 
Gps india product profile
Gps india product profileGps india product profile
Gps india product profile
 
Raycmltv
RaycmltvRaycmltv
Raycmltv
 
Km lux-99-100 k-200k
Km lux-99-100 k-200kKm lux-99-100 k-200k
Km lux-99-100 k-200k
 
Tk2050
Tk2050Tk2050
Tk2050
 
Photoelectric detectors xs
Photoelectric detectors xsPhotoelectric detectors xs
Photoelectric detectors xs
 
Vibration rates
Vibration ratesVibration rates
Vibration rates
 
Datasheet of IDH10SG60C
Datasheet of IDH10SG60CDatasheet of IDH10SG60C
Datasheet of IDH10SG60C
 
Power transmission _distribution_line_trainer_tl_04_26
Power transmission _distribution_line_trainer_tl_04_26Power transmission _distribution_line_trainer_tl_04_26
Power transmission _distribution_line_trainer_tl_04_26
 
Presentasi RCMEAE 2012 & Sokendai Asian Winter School 2012
Presentasi RCMEAE 2012 & Sokendai Asian Winter School 2012Presentasi RCMEAE 2012 & Sokendai Asian Winter School 2012
Presentasi RCMEAE 2012 & Sokendai Asian Winter School 2012
 
ATG Electronics iBright E48i LED Tube Light
ATG Electronics iBright E48i LED Tube LightATG Electronics iBright E48i LED Tube Light
ATG Electronics iBright E48i LED Tube Light
 
Cctv Camera
Cctv CameraCctv Camera
Cctv Camera
 

Similar to Ax 70 tn-130tn_200tn

Similar to Ax 70 tn-130tn_200tn (20)

Ultrasonic Level Transmitter
Ultrasonic Level TransmitterUltrasonic Level Transmitter
Ultrasonic Level Transmitter
 
9730 datasheet
9730 datasheet9730 datasheet
9730 datasheet
 
Takex PB-50HF-KH Instruction Manual
Takex PB-50HF-KH Instruction ManualTakex PB-50HF-KH Instruction Manual
Takex PB-50HF-KH Instruction Manual
 
Takex PB-100HF-KH Instruction Manual
Takex PB-100HF-KH Instruction ManualTakex PB-100HF-KH Instruction Manual
Takex PB-100HF-KH Instruction Manual
 
Takex PB-200HF-KH Instruction Manual
Takex PB-200HF-KH Instruction ManualTakex PB-200HF-KH Instruction Manual
Takex PB-200HF-KH Instruction Manual
 
Ultrasonic Level Transmitter
Ultrasonic Level TransmitterUltrasonic Level Transmitter
Ultrasonic Level Transmitter
 
Ax100 tf
Ax100 tfAx100 tf
Ax100 tf
 
Ax200 tf
Ax200 tfAx200 tf
Ax200 tf
 
Catv1 Fuente Serie Gmx (Stand By)
Catv1  Fuente Serie Gmx (Stand By)Catv1  Fuente Serie Gmx (Stand By)
Catv1 Fuente Serie Gmx (Stand By)
 
Iwatsu curve tracer-catalog-denkei
Iwatsu curve tracer-catalog-denkeiIwatsu curve tracer-catalog-denkei
Iwatsu curve tracer-catalog-denkei
 
Brymen BM157 BM357 User's Manual
Brymen BM157 BM357 User's ManualBrymen BM157 BM357 User's Manual
Brymen BM157 BM357 User's Manual
 
Mirage dual
Mirage dualMirage dual
Mirage dual
 
Digital AC Leakage Clamp Meters KEW 2434
Digital AC Leakage Clamp Meters KEW 2434Digital AC Leakage Clamp Meters KEW 2434
Digital AC Leakage Clamp Meters KEW 2434
 
Wago jumpflex catalog
Wago jumpflex catalogWago jumpflex catalog
Wago jumpflex catalog
 
Mean well d-30 dual out
Mean well   d-30 dual outMean well   d-30 dual out
Mean well d-30 dual out
 
emi/emc
emi/emcemi/emc
emi/emc
 
Noiseken ins220 Impulse Noise Simulator denkei
Noiseken ins220 Impulse Noise Simulator denkeiNoiseken ins220 Impulse Noise Simulator denkei
Noiseken ins220 Impulse Noise Simulator denkei
 
Noiseken ins220 Impulse Noise Simulator denkei
Noiseken ins220 Impulse Noise Simulator denkeiNoiseken ins220 Impulse Noise Simulator denkei
Noiseken ins220 Impulse Noise Simulator denkei
 
Honeywell aurora-install-guide
Honeywell aurora-install-guideHoneywell aurora-install-guide
Honeywell aurora-install-guide
 
3281 - 3282
3281 - 32823281 - 3282
3281 - 3282
 

More from sanzen enterprises (20)

Odyssey 3
Odyssey 3Odyssey 3
Odyssey 3
 
Vm3240va ce cb1e
Vm3240va ce cb1eVm3240va ce cb1e
Vm3240va ce cb1e
 
Vm 3240 e
Vm 3240 eVm 3240 e
Vm 3240 e
 
Sv200ma mi1e
Sv200ma mi1eSv200ma mi1e
Sv200ma mi1e
 
Sc610 cs1e
Sc610 cs1eSc610 cs1e
Sc610 cs1e
 
Sc610 cs1e
Sc610 cs1eSc610 cs1e
Sc610 cs1e
 
Cs154 cs1e
Cs154 cs1eCs154 cs1e
Cs154 cs1e
 
Bs678 cs1e tei rev1
Bs678 cs1e tei rev1Bs678 cs1e tei rev1
Bs678 cs1e tei rev1
 
Bs633a data sheet
Bs633a data sheetBs633a data sheet
Bs633a data sheet
 
Data sheet en_us_1902186891
Data sheet en_us_1902186891Data sheet en_us_1902186891
Data sheet en_us_1902186891
 
Data sheet en_us_1902186891
Data sheet en_us_1902186891Data sheet en_us_1902186891
Data sheet en_us_1902186891
 
Data sheet en_us_1911721995
Data sheet en_us_1911721995Data sheet en_us_1911721995
Data sheet en_us_1911721995
 
La1 uw24 x column loudspeakers
La1 uw24 x column loudspeakersLa1 uw24 x column loudspeakers
La1 uw24 x column loudspeakers
 
Bgt 4139 ts
Bgt 4139 tsBgt 4139 ts
Bgt 4139 ts
 
Bgt 5504 a
Bgt 5504 aBgt 5504 a
Bgt 5504 a
 
Bgt 5140 a
Bgt 5140 aBgt 5140 a
Bgt 5140 a
 
Bgt 9120 ts
Bgt 9120 tsBgt 9120 ts
Bgt 9120 ts
 
Bgt 9119 as
Bgt 9119 asBgt 9119 as
Bgt 9119 as
 
Bgt 720 tos
Bgt 720 tosBgt 720 tos
Bgt 720 tos
 
Bgt 5221 as
Bgt 5221 asBgt 5221 as
Bgt 5221 as
 

Ax 70 tn-130tn_200tn

  • 1. SHORT RANGE PHOTOELECTRIC DETECTOR AX-70 / 130 / 200TN SPECIFICATIONS Model AX-70TN AX-130TN AX-200TN AX-100TF AX-200TF Detection method Infrared beam interruption detection (STANDARD MODEL) AX-100 / 200TF Maximum detection range 20m (70ft.) 40m (130ft.) 60m (200ft.) 30m (100ft.) 60m (200ft.) Maximum arrival range 200m (700ft.) 400m (1300ft.) 600m (2000ft.) 300m (1000ft.) 600m (2000ft.) Interruption period Selectable between 50, 100, 250, and 500m sec. (ENHANCED MODEL) Selectable beam frequency 4 channel Power supply 10.5 - 28V DC Current consumption (transmitter + receiver) 38mA (max.) 41mA (max.) 45mA (max.) 44mA (max.) 48mA (max.) Alarm period 2sec. (±1) nominal Alarm output N.C. 28V DC, 0.2A (max.) N.C./N.O. 28V DC, 0.2A (max.) D.Q. output N.C. 28V DC, 0.2A (max.) Tamper switch Opens when cover is removed at 28V DC, 0.2A max. -35°C to +60°C (-31°F to +140°F) Operating temperature Use the optional heating unit (HU-3) in conditions of -25°C (-13°F) or below. Operating humidity 95% max. Alignment angle ± 90° Horizontal, ± 5° Vertical Mounting Wall and pole mounting Weight (transmitter + receiver) 650g (22.9oz.) 700g (24.7oz.) Housing protection (EN 00529) IP65 *Specifications and design are subject to change without prior notice. NOTE: These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion. These products conform to the EMC Directive 89/336 ECC. DIMENSIONS OPTIONS ■ HU-3 : Heating Unit Heating unit for severe low temperature conditions 24V DC/AC, 420mA max. 36 (1.4) 1 set (2 units) ■ BC-3 : Back Cover Can be used to cover mounting pole. 83.5 (3.3) 170 (6.7) 1 set (2 units) ■ PSC-3 : Pole Side Cover Cover for installing 2 units to 1 pole. 65 (2.6) 69.5 (2.7) 1 set (2 units) Dimensions : mm (inches) OPTEX CO., LTD. (ISO 9001 Certified by LRQA / ISO14001 Certified by JET) The Best Short Range Photoelectric Detector 5-8-12 Ogoto, Otsu, Shiga, 520-0101 Japan TEL +81(0)77 579 8670 FAX +81(0)77 579 8190 http://www.optex.co.jp/e AX-TN/TF series is a compact photoelectric detector with "the IP65 high durability", and OPTEX INCORPORATED (USA) http://www.optexamerica.com OPTEX (EUROPE) LTD. (UK) http://www.optexeurope.com "stable detection performance". OPTEX SECURITY SAS (FRANCE) http://www.optex-security.com OPTEX KOREA CO., LTD. (KOREA) http://www.optexkorea.com These features reduce false alarms drastically caused by outdoor severe environmental changes and OPTEX SECURITY Sp. z o.o. (POLAND) OPTEX(DONGGUAN) CO., LTD. http://www.optexchina.com provide a wide range of applications. Shenzhen office(CHINA) “Take Care of the Environment” This catalogue uses recycled paper No. 75107-01-14931-0703
  • 2. SHORT RANGE PHOTOELECTRIC DETECTOR AX-70 / 130 / 200TN (STANDARD MODEL) The best short range photoelectric AX-100 / 200TF (ENHANCED MODEL) □ IP65 structure with high sealing rubber packing □ Anti-frost hood cover detector from OPTEX Rubber packing is used for all conceivable points where water or dust may penetrate, such as wiring holes, wire ports and the outer A hood is installed to prevent frost forming on lower beams. It also makes the maintenance easy because the surface of the cover is flat. □ Lightning protection chassis. Prevention from dust, bugs An improved Electro-Magnetic Interference surge absorber and high and water delivers performance with surge resistive relay has been installed to protect from lightning surges higher reliability against false alarms and maintain stable operation. and breakdowns. Rubber Lightning Protection Level packing IP65 Will remain stable against over Waterproof. Wiring Conventional 14kV of lightning surge. Protected against water jets from hole Detector any direction Dust-tight. AX Series No ingress of dust. 0 2 4 6 8 10 12 14 International Protection Code. Lightning Surge Voltage Level (kV) It shows the degrees of protection provided by enclosures. □ Easy angle adjustment It allows the installer to finely adjust the beam easily. 5 degrees of water conditions were [ Horizontally ±90° with hand ] used to evaluate the protection [ Vertically ±5° with screwdriver ] against water Tests were conducted using a water □ High grade spherical lens jet stream that applied 12.5 The high grade spherical lens creates more sharply defined & precise liters/min of water at a distance of infrared beams compared to ordinary fresnel lenses. approximately 3 meters for roughly 3 minutes. This test was directly applied to the chassis of the AX-TN □ A.G.C. (Automatic Gain Control) Circuit and TF series. A.G.C. circuit continually monitors for gradual changes in the signal's strength caused by changing weather conditions. It adjusts the sensitivity accordingly to maintain the proper signal level for the current environmental conditions. The tests resulted with the AX-TN/TF unit undamaged due to the highly □ 99% beam blocking stability durable IP65 rated structure. It aids in the prevention of water damage to Enables stable operation with as much as 99% loss of beam energy the unit while keeping the detector caused by heavy rain, dust storms, fog or snow. operating accurately in outdoor environments. □ Adjustable beam interruption period The beam interruption time can be adjusted to fit any application. For example, when protecting a wall or fence, a longer interruption time will catch intruders. AX-100/200TF only □ Selectable beam frequencies □ 4 step alarm indicator LED for fast & accurate optical alignment The selectable beam frequencies can be used to avoid unwanted The alignment condition crosstalk that can occur when using multiple photobeams for long is visually displayed on LED is "ON" distance or beam stacking applications. the LED. It shows the Before alignment. alignment condition by 1. Long distance stacking using 4 different process TRANSMITTER RECEIVER RECEIVER TRANSMITTER TRANSMITTER RECEIVER to achieve accurate and LED is "Fast Flickering" easy alignment before Ch1 Ch1 Ch1 Ch1 Ch3 Ch3 fine tuning. Under the beam alignment. LED indication changes by beam receiving level. 2. Two beam long distance TRANSMITTER RECEIVER RECEIVER TRANSMITTER TRANSMITTER RECEIVER LED is "Slow Flickering" Ch1 Ch1 Ch1 Ch1 Ch2 Ch2 Beam energy fromtransmitter is reaching receiver. Ch3 Ch3 Ch3 Ch3 Ch4 Ch4 TRANSMITTER RECEIVER RECEIVER TRANSMITTER TRANSMITTER RECEIVER OPTEX succeeded to strengthen the basic performance and ability of photoelectric detector to reduce false alarms LED is "OFF" under severe outdoor environments. □ D.Q. Circuit Ready for fine tuning D.Q. circuit (environmental disqualification) sends a trouble signal when The rubber packing for wiring hole prevents rain, dust, and tiny insects from getting into the unit and the widely the beam strength is below and acceptable level due to heavy fog, rain, snow or other changes in the installation site. The trouble signal output Fine Adjustment with voltmeter designed optical pitch maximizes the detection principle of twin beam. continues as long as the beam strength is below an acceptable level.