BUILDING SCIENCE 2 ARC3413
PROJECT 1
LIGHTING AND ACOUSTIC PERFORMANCE
EVALUATION AND DESIGN
GREYSKYMORNING CAFE
TEAM MEMBERS
BRYAN LUM ZI YANG 0314959
KAN JIA WEI ADRIAN 0319384
HONG SANG WON 0314661
JOSHUA LEE YEE KAI 0315820
KEN WONG CHUN THIM 0315334
KENNETH CHANG WEI JIAN 0318252
TUTOR
MR AZIM SULAIMAN
2
DECLARATION OF SUBMISSION
This is to certify that:
1) The Report comprises our original work towards the course work on Building
Science 2 (ARC3413),
2) Due acknowledgements have been made in the text to all other material used.
Signed by:
STUDENT NAME
BRYAN LUM ZI YANG
KAN JIA WEI ADRIAN
HONG SANG WON
JOSHUA LEE YEE KAI
KEN WONG CHUN THIM
KENNETH CHANG WEI JIAN
3
ACKNOWLEDGEMENT
We would like to express our sincere thanks and gratification to our tutor, Mr Azim
Sulaiman for guiding us throughout the entire working and study process and going
out of his way to ensure that the group stays on the right track throughout the progress
of the project. We would also like to extend our thanks to the manager and staff on
duty at Greyskymorning Cafe on our multiple for their willingness to help and
cooperate with the advancement of our assignment, providing invaluable information
and also taking the extra step of guiding us around the building to explain and show
all of the systems. Finally, we give thanks to each and every one of our very own group
members whom participated flawlessly and were quick and efficient in conducting and
executing their respective parts of the project with contributed to a successful
completion of the project.
4
LIST OF FIGURES, PLATES, ILLUSTRATIONS
Figure1.01 Exterior View of GreyskymorningCafé.
Figure1.02 Exterior Panorama View.
Figure1.03 Interior Entrance Panorama View.
Figure1.04 Interior Cashier Counter Panorama View.
Figure1.05 Interior Back Panorama View.
Figure2.01 Lux Meter.
Figure2.02 Lux Meter General SpecificationTable
Figure2.03 Lux Meter Electrical SpecificationTable.
Figure2.04 Sound Level Meter.
Figure2.05 Sound Meter General SpecificationTable.
Figure2.06 Measuring Tape.
Figure2.07 DSLR Camera.
Figure2.08 Bryan measuring the dimensions of building.
Figure2.09 Joshua converting raw data into hard data onsite.
Figure2.10 Adrian obtaining the lighting and acoustic data.
Figure2.11 Sang Won Conducting Preliminary Investigations and Sketches.
5
Figure3.01 The External South Facing Side of Duke University School of Nursing.
Figure3.02 Site Plan of the University Marked On The Map.
Figure3.03 Exterior of the Café Duson in 2010.
Figure3.04 Site Boundary Highlighted on A Site Plan of the Café Duson.
Figure3.05 Squares Showing Lights Whilst Triangles Indicate Lights That Are Not Shown
Figure3.06 Lights Being Pointed Through the Use of An Elevation Drawing.
Figure3.07 Courtyard Luminaire Schedule.
Figure3.08 Ground Floor Plan with Gridline of GreyskymorningCafe.
Figure3.09 Zoning Spaces of GreyskymorningCafe.
Figure3.10 Non-peak Lux Reading at 1.5m According to Gridline.
Figure3.11 Peak Lux Reading at 1.5m According to Gridline.
Figure3.12 Non-peak Lux Reading at 1.0m According to Gridline.
Figure3.13 Peak Lux Reading at 1.0m According to Gridline.
Figure3.14 Lux Reading at 1.5m. (Standing)
Figure3.15 Lux Reading at 1.0m. (Sitting)
Figure3.16 Non-peak Hour (11.30AM) Zone Dining Space.
Figure3.17 Image of Zone A Dining Space.
Figure3.18 Daylight (11.30AM) Calculation for Zone A.
Figure3.19 Daylight (11.30AM) Factor Calculation for Zone A.
Figure3.20 Daylight Factors and DistributionTable.
Figure3.21 Non-Peak Hour (11.30AM) Zone Kitchen Space.
Figure3.22 Panorama Image of Zone B Kitchen Space.
Figure3.23 Daylight (11.30AM) Calculation for Zone B.
Figure3.24 Daylight (11.30AM) Factor Calculation for Zone B.
6
Figure3.25 Daylight Factors and DistributionTable.
Figure3.26 Non-Peak Hour (11.30AM) Zone Service Area.
Figure3.27 Image of Zone C Service Area.
Figure3.28 Daylight (11.30AM) Calculation for Zone C.
Figure3.29 Daylight (11.30AM) Factor Calculation for Zone C.
Figure3.30 Daylight Factors and DistributionTable.
Figure3.31 Plan and Light Analysis Diagram obtained via Revit.
Figure3.32 Plan and Light Analysis Diagram obtained via Revit.
Figure3.33 Plan and Light Analysis Diagram obtained via Revit.
Figure3.34 Plan and Light Analysis Diagram obtained via Revit.
Figure3.35 Plan and Light Analysis Diagram obtained via Revit.
Figure3.36 Plan and Light Analysis Diagram obtained via Revit.
Figure3.37 Plan and Light Analysis Diagram obtained via Revit.
Figure3.38 Plan and Light Analysis Diagram obtained via Revit.
Figure3.39 Dining Area Facing the West Sun.
Figure3.40 Kitchen Space Facing the West Sun.
Figure3.41 Service Area Facing the Morning Sun.
Figure3.42 Natural Skylight Illuminates The Interior Spaces.
Figure3.43 Kitchen Area Illuminated with Warm Spotlights.
Figure3.44Dining Spaces Illuminated with Warm Spotlights.
Figure3.45Warm Mood Created by Artificial Lightings.
Figure4.01 Sky City and the Auckland Skyline.
Figure4.02 Site of Sky City in Auckland.
Figure4.03 Hotel Layout.
Figure4.04 Lightweight Drywall.
7
Figure4.05 Perforated Acoustic Ceiling Tiles.
Figure4.06 Pre-Renovation Measured Noise Levels.
Figure4.07 Commissioning Measured Noise Levels.
Figure4.08 Gridlines WhichAre Used to Collect Acoustic Data.
Figure4.09 Non-Peak Acoustic Reading.
Figure4.10 Non-Peak Acoustic Reading.
Figure4.11 Peak Acoustic Reading.
Figure4.12 Peak Acoustic Reading.
Figure4.13 Non-Peak Sum Intensity and Sound Intensity Levels
Figure4.14 Non-Peak Sum Intensity and Sound Intensity Levels
Figure4.15 Noise Criteria for Acoustic Environment in Building Interiors.
Figure4.16 Sound Decibel Table.
Figure4.17 Plan with Indications for SRI Calculations.
Figure4.18 Plan with Indications of The Measured Outdoor Acoustic Levels.
8
TABLE OF CONTENTS
SUBJECT PAGE
Cover Page
Declaration of Submission
Acknowledgement
List of Figures, Plates, Illustrations
Table of Contents
Abstract
1.0 INTRODUCTION
1.1 Aim and Objectives
1.2 Site Introduction
2.0 METHODOLOGY
2.1 Equipment and Specifications
2.1.1 Lux Meter
2.1.2 Sound Level Meter
2.1.3 Measuring Tape
2.1.4 Camera
2.2 Data Collection Method
2.2.1 Site Study
2.2.2 Procedure
3.0 LIGHTING
3.1 Precedent Studies
3.1.1 Introduction
3.1.2 Methodology
9
3.1.3 Analysis
3.2 Case Study
3.2.1 Site and Zoning
3.2.2 Data Tabulation and Analysis
3.2.3 Material Specification
3.2.4 Artificial Lighting Fixtures and Specifications
3.2.5 Daylight Factor Analysis
3.2.6 Artificial Light Analysis
3.2.7 Daylight and Lighting Diagrams
3.2.8 Lighting Analysis
4.0 ACOUSTICS
4.1 Precedent Studies
4.1.1 Introduction
4.1.2 Objectives and Issues
4.1.3 Existing Construction
4.1.4 Pre-Renovation Measurements
4.1.5 Design Standard
4.1.6 Final Treatment
4.1.7 Commissioning Measurements
4.1.8 Discussion and Conclusion
4.2 Case Study
4.2.1 Site and Zoning
4.2.2 Data Tabulation and Analysis
4.2.3 Material Specification
4.2.4 Fixtures and Specifications
4.2.5 Sound Reduction Index Calculation
10
4.2.6 Reverberation Time
4.2.7 Acoustic Analysis and Evaluation
5.0 CONCLUSION
APPENDIX
REFERENCES
11
ABSTRACT
This research report aims to look into the lighting and acoustic properties of a chosen
commercial building, Greyskymorning Café in SS13 Subang Jaya. The services and
parts of the building include: the cashier counter, the kitchen, the seating location, the
porch, and the back area connecting to the service area as well as the adjacent shoplot
to the toilets. Throughout the findings and analysis of lighting and acoustics, the
functions and any information of the systems will be studied extensively in conjunction
with the building to further understand the importance of the system in a building’s
properties operation. Findings and conclusions that are made as a result of this study
will be made through our understanding of these said services. Not least forth these
services will be adjudged to and by the Malaysian Standard 1525 (MS1525) and
requirements as well as other relevant rules and regulations stipulated by relevant
authorities and organisations.
12
1.0 INTRODUCTION
1.1 AIM AND OBJECTIVES
The aim of the assignment is to gain a better understanding in the lighting and acoustic
systems as well as their properties in a given space or building. Furthermore, from the
experience gained from this study the aim would be to compile and record the data
and provide critical analysis in the form of a written report.
The objectives of this assignment include and procurement of a complete written
report with data gained through documentation from the site visits on the building. The
criteria of the analysis of the space in relation to the lighting and acoustic and how
these properties work together is also to be made an objective. At the end of the
assignment students should have a better understanding on lighting and acoustics, as
well as all its relevant associates that come with it, including better understanding of
calculations of light and acoustic (Lumen and PSALI), as well as how different
materials and building layout all correspond with lighting and acoustic performance
13
1.2 SITE INTRODUCTION
Figure 1.01 Exterior View of GreyskymorningCafé. (Wong,2016)
Greyskymorning Café, the site chosen for this case study is an infill building that is sandwiched in
between a church, City Harvest Church, and a restaurant, Food Industrie. The café also serves as an
access point and circulation between these areas, as well as to more points of the building on the
second floor, as well as a saloon that is only accessible via entering Greskymorning. All these
commercial and service buildings form an entire structure formally known as EX8, with its own
compound dictated by a fence as well as parking lots in and around the structure. EX8 is located in
SS13 Subang Jaya where it is predominantly surrounded by factories and manufacturing plants.
However, within the vicinity also lies an International School, and a football stadium.
The entire building, including Greyskymorning is covered in black paint and uses glass and windows
exponentially to take advantage of the large amounts of sunlight that Malaysia gets everyday. Natural
lighting is used extensively as a result, and the building is cooled with a mixture of air conditioning
systems and natural ventilation. The building also uses a heavy amount of steel and bricks that is left
as it is to provide a more modern feel and look, a movement which is getting more and more popular in
this region.
Greyskymorning Café has many doors and exits with links to and around other portions of EX8, and the
café was chosen as our site of our study as our initial analysis revealed that due to the heavy reliance
on natural lighting and interesting use of materials the data gained would provide very different results
from analysis from different parts of the day. The site is also located in a factory heavy location which
we feel would provide different acoustic performance results on different parts of the day as well.
14
Figure 1.02 Exterior Panorama View. (Hong,2016)
Figure 1.03 Interior Entrance Panorama View. (Hong,2016)
Figure 1.04 Interior Cashier Counter Panorama View. (Hong,2016)
Figure 1.05 Interior Back Panorama View. (Hong,2016)
15
2.0 METHODOLOGY
2.1 EQUIPMENT AND SPECIFICATIONS
2.1.1 LUX METER
Figure 2.01 Lux Meter. (http://www.bsktech.com/lutron.html)
The lux meter is a digital light meter manufactured by Lutron Electronic Enterprise Co.
Ltd and functions to measure the luminous flux unit and illuminance level. This device
is highly accurate, using photo diodes and multi-colour correction filter with spectrums
that meet the C.I.E’s international code of standards. This lux meter is used as our
source for lighting data collected on site and is sourced from the University. The
specifications of the device are listed below.
16
GENERAL SPECIFICATION
Display 13mm (0.5”) LCD
Range 0 – 50 000 Lux. 3 Presets
Zero Adjustment Internal Adjustment
Over-Input Indication of “1” on LCD
Sampling Time 0.4 Seconds
Sensor Structure Photo Diode and Color Correction Filter
Operating Temperature 0 – 50Celcius (32 – 122 Fahrenheit)
Operating Humidity Maximum Capacity at 80% R.H.
Power Supply DC 9V Battery, 006P, MN1604 (PP3) or equivalent
Power Consumption Approximately DC 2 mA
Dimensions Main Body:
108x73x23 mm
Sensor Probe:
82x55x7 mm
Weight 160g (WithBattery)
Miscellaneous 1) Instruction Manual
2) Leather CarryingCase
Figure 2.02 Lux Meter General SpecificationTable.
ELECTRICAL SPECIFICATION (23±5)
RANGE RESOLUTION ACCURACY
2 000 LUX 1 LUX ± ( 5 % + 2 d )
20 000 LUX 10 LUX ± ( 5 % + 2 d )
50 000 LUX 100 LUX ± ( 5 % + 2 d )
*Accuracy of sensor is tested by standard parallel tungsten lamp light of 2856K temperature.
Figure 2.03 Lux Meter Electrical SpecificationTable.
17
2.1.2 SOUND LEVEL METER
Figure 2.04 Sound Level Meter. (http://www.bsktech.com/lutron.html)
The sound level meter is a digital sound meter manufactured by Lutron Electronic
Enterprise Co. Ltd and functions to measure the acoustic levels and decibel levels.
This device is highly accurate and picks up any minute sound if pointed at the source
in the correct manner. This sound meter is used as our source for acoustic data
collected on site and is sourced from the University. The specifications of the device
are listed below.
18
GENERAL SPECIFICATION
Function dB ( A & C Frequency Weighting ), Time Weighting ( Fast, Slow ),
Hold, Memory ( Max. & Min. ), Peak Hold, AC Output RS232
Output.
Meter Default Function Range Set to Auto Range.
Frequency Weighting Set to A Weighting.
Time Weighting Set to Fast.
Measurement Range 30 – 130 dB
Resolution 0.1 dB
Range Selector Auto Range: 30 – 130 dB.
Manual Range: 3 Ranges, 30 – 80 dB, 50 – 100 dB,
80 – 130 dB, 50 dB On Each
Step with Over & Under
Range Indicating.
Frequency 31.5 – 8 000 Hz
Microphone Type Electric Condenser Microphone
Microphone Size 12.7 mm DIA ( 0.5 inch )
Frequency
Weighting Network
Characteristics of A & C
* A Weighting
The Characteristics Is Simulated As “Human Ear Listening”
Response. If Making the Environmental Sound Level
Measurement, Always Select to A Weighting.
Time Weighting
(Fast and Slow)
Fast – t=200 ms, Slow – t=500 ms
* FAST Range Is the Simulated Human Ear Response Time.
* SLOW Range Is Easier to Get the Average
Calibrator B & K ( Bruel & kjaer ), MULTIFUNCTION ACOUSTIC CALIBRATOR
4226
Output Signal *AC Output: AC 0.5 Vrms Corresponding to Each Range Step. Out
Put Impedance - 600 ohm
*RS232 Output
Output Terminal Terminal 1: RS232 Computer Interface Terminal, Photo Couple
Isolated.
Terminal 2: AC Output Terminal
Terminal Socket Size: 3.5mm dia. Phone Socket.
Calibration VR Built in External Calibration VR, Easy to Calibrate on 94 dB Level by
Screw Driver
Figure 2.05 Sound Meter General SpecificationTable.
19
2.1.3 MEASURING TAPE
Figure 2.06 Measuring Tape.
(https://www.amazon.com/Stanley-33-716-16-Foot-4-Inch-FatMax/dp/B00009OYGJ)
The measuring tape is used to measure a variety of items and specifications in and
around the building and site during the study period, including measurement of the
dimensions of the building, walls and stairs. It is also used to measure height,
especially the height of light and acoustic sources. Finally the tape is also used to
ensure the constant height that the acoustic and light reading are taken from are
constant and consistent.
2.1.4 CAMERA
Figure 2.07 DSLR Camera.
(https://www.bhphotovideo.com/c/buy/SLR-Digital-Cameras/ci/6222/N/4288586280)
20
The DSLR camera is used as the primary equipment to record and capture pictures of
the building, lighting and acoustic conditions, and the appliances that are deemed
necessary to the study. Multiple cameras belonging to fellow members were used. In
some instances cameras from mobile phones were used when DSLR cameras were
not readily available.
2.2 DATA COLLETION METHOD
2.2.1 SITE STUDY
Figure 2.08 Bryan measuring the dimensions of building. (Wong,2016)
The site visit consisted of several trips to the site over the course of the 9 week period
in which we were given to complete the assignment. This was done to compensate
the insufficient time to conduct a full study and to accommodate for class scheduling
as well as the fact that data from different parts of the day were needed hence several
trips on different times of the day were justified. The first trips consisted of preliminary
investigations, followed by measurements and data gathering in the subsequent trips
to the site. The team was split into teams, namely the data team, photography team
and measurement team to ensure efficient work productivity.
21
Figure 2.09 Joshua converting raw data into hard data onsite. (Wong,2016)
The preliminary investigations as well as the photo taking were quite straight forward.
Sketches were drawn, and photos of the entire building, inside and out, as well as all
the lighting, acoustic and appliance components were taken. From then the
measurement team sought to measure the dimensions of the site, obtaining a floor
plan as a result and plotted the plan with a gridline of 1.5m spacing for the purpose of
data gathering.
Figure 2.10 Adrian obtaining the lighting and acoustic data. (Wong,2016)
22
Once the gridline has been established, the data team took on the task of obtaining
the data for both the lighting and acoustics from a height of 1m and 1.5m from the
floor. In addition to obtaining data indoors, the data for outdoor areas immediately
surrounding the building were also gathered, albeit in less quantities. Only the ground
floor of the building was used for the study and the building was categorised into
different zones for further analysis.
2.2.2 PROCEDURE
Figure 2.11 Sang Won Conducting Preliminary Investigations and Sketches. (Kan,2016)
Below is the procedure list of the entire study process:
1. Preliminary investigation and photo survey, indication of light types and sources.
2. Measurement and production of floor plans, gridlines.
3. Data gathering for light and acoustic using proper equipment at heights of 1m and
1.5m
4. Analysis of data and production of report.
23
3.0 LIGHTING
3.1 PRECEDENT STUDY
3.1.1 INTRODUCTION
Figure 3.01 The External South Facing Side of Duke University School of Nursing.
Figure 3.02 Site Plan of the University MarkedOn The Map.
24
Located in Durham, North Carolina, along Trent Drive, sits Duke University School of
Nursing. Established in 1931 on January 2nd, it is currently ranked as 6th among the
best nursing schools in the U.S. as of 2016. However, for our particular precedent
studies, we are looking more in depth into the Cafe Duson located in the courtyard
which is located in the East facing side of the university.
Figure 3.03 Exterior of the Café Duson in 2010.
The main reason that this building and site was chosen as our focus for lighting
precedents was due to the similar layout as well as similarity of the facade of the
overall cafe with the floor to ceiling height glass curtain walls. This provides us a
platform in which we could get a good initial understanding on the properties and
materials that we would face in our study later on.
25
3.1.2 METHODOLODY
Figure 3.04 Site Boundary Highlighted on A Site Plan of the Café Duson.
26
Figure 3.05 Squares Showing Lights Whilst Triangles Indicate Lights That Are Not Shown On The
Plan.
The research started by looking at the exterior of the courtyard and how did the lighting
coming from the outside would eventually affect the lighting located inside the Cafe
Duson. The boundary line was set up and the materiality of the overall courtyard was
identified. Three types of surfaces were identified and their reflectance was also noted,
which were the following:
1. Natural Cleft Bluestone Walkway and Courtyard at 15% reflectance
2. Duke Stone Retaining Walls at 20% reflectance
27
3. Gray Painted Aluminum Mullions at 25% reflectance
Following that, other existing conditions of the exterior were identified and noted down
as well, including glazing, specifications of the existing site lighting as well as any of
the other existing lighting features as well.
Figure 3.06 Lights Being Pointed Through the Use of An Elevation Drawing.
Specifications and glazing values of the two identified types of glass are noted as
below:
1. 1” Insulated Glass Curtain Wall System of Café DUSON with U-Value of 0.57,
Transmittance of 0.55 and Shading Coefficient of 0.45
2. 1” Insulated Glass – Laminated (door glass) with U-Value of 0.57,
Transmittance of 0.55 and Shading Coefficient of 0.45
28
The specifications for the two types of lighting fixtures noted down below:
Figure 3.07 Courtyard Luminaire Schedule.
3.1.3 ANALYSIS
Through the research gathered as well as observations conducted on site, the exterior
does not seem to directly affect the interior as the spacing of the light as well as the
strength do not seem to contribute or affect the ambient luminosity of the interior of the
cafe. The surrounding landscape also provides sufficient shading that can help solve
any glares issues that may occur with the massive glass curtain walls that make up
the facade of the Cafe Duson.
29
3.2 CASE STUDY
3.2.1 SITE AND ZONING
Figure 3.08 Ground Floor Plan with Gridline of GreyskymorningCafe.
Figure 3.09 Zoning Spaces of GreyskymorningCafe.
30
3.2.2 DATA TABULATION AND ANALYSIS
*The lightings were recorded and measured at 1.0m and 1.5m respectively.
LIGHTING DATA
UNIT: LUX (lx)
HEIGHT: 1.5M (STANDING)
Figure 3.10 Non-peak Lux Reading at 1.5m According to Gridline.
1.5METER (LUX)
PEAK HOURS 6.00PM - 6.15PM
GRID A B C D E F G H I J K
1 47 17 13 11 3 3 2 2 0.7
2 39 23 16 9 3 3 3 2 0.9
3 18 22 11 7 5 5 4 1 3 3 14
4 41 17 9 2 5 5 1 1 0.9 0.8 3
5 64 63 63
6 64 34 64
7 64 38 64
Figure 3.11 Peak Lux Reading at 1.5m According to Gridline.
LEGEND
A DINING RED
B KITCHEN YELLOW
C SERVICE BLUE
1.5METER (LUX)
NON PEAK HOURS 11.30AM - 12.00PM
GRID A B C D E F G H I J K
1 255 85 60 62 33 21 12 15 7
2 252 148 93 32 15 12 10 12 11
3 192 144 83 55 43 45 44 31 15 12 34
4 75 61 53 33 10 15 11 12 8 11 16
5 195 193 55
6 230 225 33
7 221 218 45
31
LIGHTING DATA
UNIT: LUX (lx)
HEIGHT: 1.0M (SITTING)
Figure 3.12 Non-peak Lux Reading at 1.0m According to Gridline.
1.0METER (LUX)
PEAK HOURS 6.00PM - 6.15PM
GRID A B C D E F G H I J K
1 42 15 10 10 3 3 2 1 0.3
2 58 23 12 11 2 2 1 1 0.5
3 21 24 15 11 4 4 3 3 4 3 15
4 51 20 11 15 4 4 2 2 1 1 4
5 23 22 22
6 32 32 32
7 36 36 36
Figure 3.13 Peak Lux Reading at 1.0m According to Gridline.
LEGEND
A DINING RED
B KITCHEN YELLOW
C SERVICE BLUE
1.0METER (LUX)
NON PEAK HOURS 11.30AM - 12.00PM
GRID A B C D E F G H I J K
1 283 122 35 37 17 17 15 12 6
2 272 194 90 38 16 15 5 6 8
3 288 149 76 67 34 29 41 28 14 12 37
4 155 82 45 30 18 26 8 8 13 17 37
5 270 162 42
6 272 161 64
7 273 275 40
32
GRID NON PEAK HOURS 11.30AM - 12.00PM PEAK HOURS 6.00PM-6.15PM
A1 255 47
A2 252 39
A3 192 18
A4 75 41
A5 195 64
A6 230 64
A7 221 64
B1 85 17
B2 148 23
B3 144 22
B4 61 17
B5 193 63
B6 225 34
B7 218 38
C1 60 13
C2 93 16
C3 83 11
C4 53 9
C5 55 63
C6 33 64
C7 45 64
D1 62 11
D2 32 9
D3 55 7
D4 33 2
E1 33 3
E2 15 3
E3 43 5
E4 10 5
F1 21 3
F2 12 3
F3 45 5
F4 15 5
33
GRID NON PEAK HOURS 11.30AM - 12.00PM PEAK HOURS 6.00PM-6.15PM
G1 12 2
G2 10 3
G3 44 4
G4 11 1
H1 15 2
H2 12 2
H3 31 1
H4 12 1
I1 7 0.7
I2 11 0.9
I3 15 3
I4 8 0.9
J3 12 3
J4 11 0.8
K3 34 14
K4 16 3
Figure 3.14 Lux Reading at 1.5m. (Standing)
LEGEND
A DINING RED
B KITCHEN YELLOW
C SERVICE BLUE
34
GRID NON PEAK HOURS 11.30AM - 12.00PM PEAK HOURS 6.00PM-6.15PM
A1 283 42
A2 272 58
A3 288 21
A4 155 51
A5 270 23
A6 272 32
A7 273 36
B1 122 15
B2 194 23
B3 149 24
B4 82 20
B5 162 22
B6 161 32
B7 275 36
C1 35 10
C2 90 12
C3 76 15
C4 45 11
C5 42 22
C6 64 32
C7 40 36
D1 37 10
D2 38 11
D3 67 11
D4 30 15
E1 17 3
E2 16 2
E3 34 4
E4 18 4
F1 17 3
F2 15 2
F3 29 4
F4 26 4
35
GRID NON PEAK HOURS 11.30AM - 12.00PM PEAK HOURS 6.00PM-6.15PM
G1 15 2
G2 5 1
G3 41 3
G4 8 2
H1 12 1
H2 6 1
H3 28 3
H4 8 2
I1 6 0.3
I2 8 0.5
I3 14 4
I4 13 1
J3 12 3
J4 17 1
K3 37 15
K4 37 4
Figure 3.15 Lux Reading at 1.0m. (Sitting)
LEGEND
A DINING RED
B KITCHEN YELLOW
C SERVICE BLUE
36
INTERPRETATION AND ANALYSIS
Observation 1
The data collected at the height of 1.5m are mostly higher than the data collected at
the height of 1m from the floor.
Discussion and Analysis 1
The data collected at the height of 1.5m are closer to the artificial lighting. Because
the surrounding walls of the café are mostly made out of glass material, daylighting
from the curtain walls also affects the interior. Also, due to the building being an infill
building, the adjacent buildings may have shades that affects the reading at the 1.5m
height, causing it to be lower in some cases.
Observation 2
The light data collected during the non-peak hour of 11.30am is significantly higher in
grid A and B, moderately high in grid C and D and lower in the vicinity of grid I.
Discussion and Analysis 2
The higher lux reading data collected at Grid A and B are due to the lights coming in
from the adjacent curtain walls of the entrance. Between grid A2 and A3 is the
entrance door, the light coming in from the entrance door affects the data significantly
till grid B2 and B3. Grid C and D being the middle part of the building has a moderately
high reading due to the light coming in from the entrance door between Grid A2 and
A3. The data collected in grid E4, F4, G4, H4 and I4 are relatively low as the building
is an infill building. Although the walls are of a curtain wall, the lux reading is low as
the adjacent space is a dimly lit restaurant. The readings in grid I1 is low as the walls
are constructed of concrete material.
37
Observation 3
The data collected during the peak hour of 6.00pm shows a lower lux reading due to
the sun setting around that time. All of Grid A can be seen showing a higher lux reading
when compared to the other Grid readings.
Discussion and Analysis 3
The higher lux reading collected at Grid A is due to the surrounding curtain walls and
it being near the entrance door. Grid A is also adjacent facing west, which is the
evening sun.
38
3.2.3 MATERIAL SPECIFICATION
ZONE A (DINING)
Component Material Colour Surface
Finish
Reflective
Value (%)
Surface
Area
(m²)
Reflec
tive
Index
Ceiling Metal deck Black Matte 20 68.0 1.519
Wall Brick wall Brown Matte 15 10.94 1.519
Painted Wall Black Matte 15 9.05 1.519
39
Curtain Glass wall Transparent Glossy 6 107.5 1.517
Floor Concrete Grey Matte 15 79.8 4.500
Door Metal Frame with glass panel Black
/transparent
Matte/
Glossy
20/6 2.5 1.517
40
Stairs Steel Black Matte 20 19.8 1.519
Frosted Glass Translucent Matte 8 19.5 1.517
41
Furniture Timber Chair Brown Glossy 10 0.8x24
= 19.2
1.46
Timber Stool Dark
Brown
Matte 12 0.7x8
= 5.6
1.328
Timber table painted Brown Matte 12 0.36 x
10
= 3.6
1.328
42
Leather sofa Black Matte 12 2.4 1.519
Reclaimed timber table Brown Matte 12 1.1 1.328
Reclaimed palette coffee table Brown Matte 12 0.9 1.328
43
ZONE B (KITCHEN)
Componen
t
Material Colour Surface
Finish
Reflecti
ve Value
(%)
Surfac
e
Area
(m²)
Reflecti
ve
Index
Ceiling Concrete Grey Matte 15 22.5 4.500
Wall Brick wall Brown Matte 15 29.2 1.519
Floor Concrete Grey Matte 15 17.1 4.5
44
Window Clear Glass Transparent Glossy 6 23.7 1.517
Furniture Timber Stool Dark
Brown
Matte 12 0.7x4
= 2.8
1.328
Reclaimed timber table Brown Matte 12 1.1 1.328
45
ZONE C (SERVICE)
Componen
t
Material Colour Surface
Finish
Reflecti
ve Value
(%)
Surfac
e
Area
(m²)
Reflecti
ve
Index
Ceiling Metal deck Black Matte 20 6.65 1.519
Wall Brick wall Brown Matte 15 1.72 1.519
Curtain Glass wall Transparent Glossy 6 31.3 1.517
46
Floor Concrete Grey Matte 15 8.4 4.5
47
3.2.4 ARTIFICIAL LIGHTING FIXTURES AND SPECIFICATIONS
Product Model Dowsing& Reynolds Vintage light bulb- squirrel
cage filament (oldfashioned Edison) E27 screw
Ratedluminous flux 610 lm
Colour renderingIndex -
Power 40 watts
Beam Angle -
Functionand Zone Placement CeilingLamp
Dimmable -
Colour Temperature 2200 Kelvin
48
Product Model LED bulb GU10
Ratedluminous flux 400lm
Colour renderingIndex 90
Power 6W
Beam Angle 36 degree
Functionand Zone Placement Spotlight beside entrance
Dimmable Yes
Colour Temperature 2700K
49
Product Model Osram 36W Warm White Lumilux Fluorescent
Tube
Ratedluminous flux 1350lm
Colour renderingIndex -
Power 18 Watt
Beam Angle -
Functionand Zone Placement Display light
Dimmable Yes
Colour Temperature 3000 Kelvin
50
Product Model OSRAMLumilux T8 Cool White
Ratedluminous flux 1350lm
Colour renderingIndex -
Power 36 Watt
Beam Angle -
Functionand Zone Placement Display light
Dimmable Yes
Colour Temperature 4000 Kelvin
51
3.2.5 DAYLIGHT FACTOR ANALYSIS
ZONE A (DINING)
Figure 3.16 Non-peak Hour (11.30AM) Zone Dining Space.
Figure 3.17 Image of Zone A Dining Space. (Lee,2016)
52
Daylight (11.30AM)
1.5m 157.25
1.0m 206.5
Average Flux 181.88
Figure 3.18 Daylight (11.30AM) Calculation for Zone A.
Zone Type Daylight Average Lux reading Daylight Factor, DF Performance based
level in based on collected on MS 1525
Malaysia E0 (Lx) data, Ex (Lx)
A Dining 12000 181.88 Fair
Figure 3.19 Daylight (11.30AM) Factor Calculation for Zone A.
Below is the daylight factors and distribution table obtained from the MS1525:
Figure 3.20 Daylight Factors and DistributionTable.
Based on MS1525, Zone A which is the dining area achieved an average lighting with
a daylight factor of 1.52%. With a daylight factor of 1.52% it can be considered dark,
however it is also a relaxing ambience for chilling and hanging out. Although the
surrounding walls are mostly curtain walls, light doesn’t really illuminate the interior
spaces. This is due to the surrounding buildings being dimly lit as well, therefore not
much lights are being transferred into the café dining spaces.
Zone DF (%) Distribution
Very bright > 6 Very large with thermal and glare problems
Bright 3 - 6 Good
Average 1 - 3 Fair
Dark 0 - 1 Poor
DF =
181.88
12000
x 100%
= 1.52%
DF =
𝐸𝑥
𝐸𝑜
x 100%
53
ZONE B (KITCHEN)
Figure 3.21 Non-Peak Hour (11.30AM) Zone Kitchen Space.
Figure 3.22 Panorama Image of Zone B Kitchen Space. (Hong,2016)
54
Daylight (11.30AM)
1.5m 123
1.0m 193.4
Average Flux 158.2
Figure 3.23 Daylight (11.30AM) Calculation for Zone B.
Figure 3.24 Daylight (11.30AM) Factor Calculation for Zone B.
Below is the daylight factors and distribution table obtained from the MS1525:
Figure 3.25 Daylight Factors and DistributionTable.
Based on MS1525, Zone B which is the kitchen space achieved an average lighting
with a daylight factor of 1.31%. The Kitchen space is located in front near the entrances
surrounded by curtain walls. The surrounding curtain walls help to illuminate the
spaces. However, it still resulted in an average lighting distribution. This is due to the
external overhang that helped to shelter the interior from the afternoon sun. The
façade is filled with overhangs that sheltered the ground floor from direct sun, providing
shade even for the outdoor sitting area.Thus, influencing the incoming light into the
kitchen space.
Zone Type Daylight
Average Lux
reading Daylight Factor, DF
Performance
based
level in based on collected on MS 1525
Malaysia E0 (Lx) data, Ex (Lx)
B Kitchen 12000 158.2 Fair
Zone DF (%) Distribution
Very bright > 6 Very large with thermal and glare problems
Bright 3 - 6 Good
Average 1 - 3 Fair
Dark 0 - 1 Poor
DF =
158.2
12000
x 100%
= 1.31%
DF =
𝐸𝑥
𝐸𝑜
x 100%
55
ZONE C (SERVICE AREA)
Figure 3.26 Non-Peak Hour (11.30AM) Zone Service Area.
Figure 3.27 Image of Zone C Service Area. (Wong,2016)
56
Figure 3.28 Daylight (11.30AM) Calculation for Zone C.
Zone Type Daylight
Average Lux
reading Daylight Factor, DF
Performance
based
level in based on collected on MS 1525
Malaysia E0 (Lx) data, Ex (Lx)
C Service 12000 16.53 Poor
Figure 3.29 Daylight (11.30AM) Factor Calculation for Zone C.
Below is the daylight factors and distribution table obtained from the MS1525,
Figure 3.30 Daylight Factors and DistributionTable.
Based on MS1525, Zone C which is the Service Area achieved a daylight factor of
0.14%. It is considerably dark in the area with poor lighting distribution according to
MS1525. Being the service area, it does not require too much lighting as hardly anyone
goes there. The space is also not designed for any uses except to access outdoor
where the maintenance of air conditions are done. Although surrounded by curtain
walls, hardly any harsh lights penetrate the space. This is due to the surrounding tall
buildings outdoor that shields the spaces from direct sunlight.
Daylight (11.30AM)
1.5m 13.05
1.0m 20
Average Flux 16.53
Zone DF (%) Distribution
Very bright > 6 Very large with thermal and glare problems
Bright 3 - 6 Good
Average 1 - 3 Fair
Dark 0 - 1 Poor
DF =
𝐸𝑥
𝐸𝑜
x 100%
DF =
16.53
12000
x 100%
= 0.14%
57
3.2.6 ARTIFICIAL LIGHT ANALYSIS
ZONE A (DINING)
Dimension of room (L X
W)(m)
13.41m x
4.62m
Total Floor Area, A (m²) 62m²
Type of Lighting Fixture LED bulb GU10
Dowsing & Reynolds
Vintage light bulb
Number of Fixture, N 19 4
Lumen of Lighting Fixture, F (lm) 400 610
Height of Luminaire (m) 4.05 2.4
Height of work level (m) 0.8 0.8
Mounting height (m) 3.45 1.4
Reflection
Factors
Ceiling-
Concrete:3
Wall- Brick wall + Black Painted
Wall: 2.0
Floor- Concrete
Flooring: 3
Room Index, RI
(K)
Utilisation Factor, UF 0.4 0.57
Maintenance Factor, MF 0.8 0.8
Illuminance Level - E (Lux)
Number of lamps
required– N
*MS1525 Recommended Dining
Illumination Level – 200
Lux
RI =
13.41 x 4.62
(13.41 + 4.62) x 3.45
= 1.00
RI =
13.41 x 4.62
(13.41 + 4.62) x 1.4
= 2.45
RI =
L x W
(L + W) x H
E =
19 (400 x 0.4 x 0.8)
62
= 39.22
E =
N x F x UF x MF
A
N =
(200 − 39.22) x 62
( 610 x 0.57 x 0.8)
= 35.83 ⋍ 36
N =
E x A
( F x UF x MF)
Analysis: The dining area of the café is under-lit and it requires another 32 Dowsing & Reynolds Vintage
light bulb to meet the requirements of MS1525. However, the cafe is surrounded by curtain walls which
allows light to brighten the interior during the day. Furthermore, the café only operates until 7pm,
therefore there is no need to worry for lighting issues during the night.
58
ZONE B (KITCHEN)
Dimension of room (L X W)(m) 4.88m x 4.89m
Total Floor Area, A (m²) 24m²
Type of Lighting Fixture LED bulb GU10
Number of Fixture, N 12
Lumen of Lighting Fixture, F (lm) 400
Height of Luminaire (m) 4.05
Height of work level (m) 0.8
Mounting height (m) 3.45
Reflection Factors Ceiling- Concrete : 3
Wall- Brick wall + Black Painted Wall : 2.0
Floor- Concrete Flooring : 3
Room Index, RI (K)
Utilisation Factor, UF 0.4
Maintenance Factor, MF 0.8
Number of lamps required – N
*MS1525 Recommended
Kitchen Illumination Level –
150 Lux
RI =
L x W
(L + W) x H
RI =
4.88 x 4.89
(4.88 + 4.89) x 3.45
= 0.71
N =
E x A
( F x UF x MF)
N =
150 x 24
( 400 x 0.4 x 0.8)
= 28.13 ⋍ 28
Analysis: The Counter/Kitchen area of the café is clearly under-lit. It would need another 16 bulbs to
meet the criteria of MS1525 Recommended Illumination level. By changing the bulbs to a higher lumen
can also be an alternative solution.
59
ZONE C (SERVICE)
Dimension of room (L X W)(m) 3.60m x1.67m
Total Floor Area, A (m²) 6m²
Type of Lighting Fixture Dowsing & Reynolds Vintage light bulb
Number of Fixture, N 1
Lumen of Lighting Fixture, F (lm) 610
Height of Luminaire (m) 2.4
Height of work level (m) 0.8
Mounting height (m) 1.4
Reflection Factors Ceiling: Concrete : 3
Wall: Brick wall + Black Painted Wall : 2.0
Floor: Concrete Flooring : 3
Room Index, RI (K)
Utilisation Factor, UF 0.57
Maintenance Factor, MF 0.8
Number of lamps required – N
*MS1525 Recommended
Service Platform Illumination
Level - 50 Lux
RI =
L x W
(L + W) x H
RI =
3.60 x 1.67
(3.60 + 1.67) x 1.4
= 0.81
N =
E x A
( F x UF x MF)
N =
50 x 6
( 610 x 0.57 x 0.8)
= 1.08 ⋍ 1
Analysis: The service area of the café is sufficiently lit as its illumination level meet the MS1525
Recommended illumination level of 50 Lux with the installed artificial lightings.
60
3.2.7 DAYLIGHT AND LIGHTING DIAGRAMS
REVIT SIMULATION, DAYLIGHT ANALYSIS
FLOOR PLAN
Figure 3.31 Plan and Light Analysis Diagram obtained via Revit.
The calculations and data recorded reveal that Zones B and C as well as a small
portion of Zone A receive the most daylight. This is due to the area being next to the
glass walls. Most of Zone A is located away from the glass walls hence less intensity.
61
DAYLIGHT ANALYSIS
ZONE A (DINING)
Figure 3.32 Plan and Light Analysis Diagram obtained via Revit.
Zone A is very well lit even though the intensity of the daylight reduces by quite a far
amount in the middle of the zone. The glass walls surrounding the zone allow for ample
daylight to enter the zone without the use of much artificial lighting needed, saving
costs.
62
DAYLIGHT ANALYSIS
ZONE B (KITCHEN)
Figure 3.33 Plan and Light Analysis Diagram obtained via Revit.
Zone B receives the most natural light among all the zones as it is nearest to the glass
walls. Furthermore, the zone is flanked by sides that allow for daylight to pass through
as well. This well-lit area means that throughout the day no artificial lighting is needed
to provide better illumination.
63
DAYLIGHT ANALYSIS
ZONE C (SERVICE)
Figure 3.34 Plan and Light Analysis Diagram obtained via Revit.
Zone C is situated at the rear of the building and also receives a substancial amount
of natural light as it is surrounded on 3 sides by glass walls. Little to no artificial lighting
is needed in this zone as well, except in the case of during evenings.
64
ARTIFICIAL LIGHTING ANALYSIS
FLOOR PLAN
Figure 3.35 Plan and Light Analysis Diagram obtained via Revit.
Based on our analysis the area with the highest concentration of artificial lighting is
located in Zone A, with the zone providing ready illumination being the dining area
for customers.
65
ARTIFICIAL LIGHTING ANALYSIS
ZONE A (DINING)
Figure 3.36 Plan and Light Analysis Diagram obtained via Revit.
Zone A is most commonly exposed to artificial lighting by the fact that it is the location
of space usage by the customers and hence extra lighting is needed when possible.
The lighting fixtures are located on the walls and ceilings.
66
ARTIFICIAL LIGHTING ANALYSIS
ZONE B (KITCHEN)
Figure 3.37 Plan and Light Analysis Diagram obtained via Revit.
Zone B receives the least amount of artificial lighting assistance due to the fact that
most of the time it isn’t needed as a result of exceptional use of natural lighting.
However, ceiling lights are installed in the event that artificial lighting is needed. Most
of the time, these lights are left off.
67
ARTIFICIAL LIGHTING ANALYSIS
ZONE C (SERVICE)
Figure 3.38 Plan and Light Analysis Diagram obtained via Revit.
Zone C also receives little to no artificial light assistance, with only a few lights in place
in the event that it is needed. Usually the natural daylight is sufficient to light the area.
68
3.2.8 LIGHTING ANALYSIS
Figure 3.39 Dining Area Facing the West Sun. (Wong,2016)
Having the front façade facing west, the evening sun lights up the interior spaces
during the evening. In the picture shown above, the entrance is seen allowing light into
the premise. With the curtain wall installation, lights illuminate the spaces allowing for
a natural light experience. Thus, also reducing the need and reliance on artificial
lighting throughout the day.
Figure 3.40 Kitchen Space Facing the West Sun. (Wong,2016)
69
The Kitchen space are also illuminated by natural light mostly. During the evening, the
west sun illuminates the interior spaces through the curtain wall. Thus, it fully optimizes
the daylighting of the evening sun in the space.
Figure 3.41 Service Area Facing the Morning Sun. (Wong,2016)
The back of the café has a service area which leads to the outdoor space for
maintenance of the air conditioner. Surrounded by curtain wall, natural light illuminates
the surrounding area, thus also reducing the reliance on artificial lightings. It can be
observed that the service area only requires a single light bulb to achieve sufficient
daylighting. Although it is considered a poor lighting distribution, however according to
MS1525, a service area is sufficiently lit to 50 Lux.
70
Figure 3.42 Natural Skylight Illuminates The Interior Spaces. (Wong,2016)
The front part of the dining spaces is also lit by natural skylight in the café. Thus,
allowing natural light from the roof top to illuminate all the way to the ground floor. With
the openings, it allows for the reduction and reliance on artificial lightings in the space.
Figure 3.43 Kitchen Area Illuminated with Warm Spotlights. (Hong,2016)
Even with all the natural lightings and transparencies, artificial lightings are also
installed to light up the interior spaces and aids the café in illuminating during the
morning or evening.
71
Although artificial lightings can provide certain aesthetic and mood to the spaces, it also
serves in a very practical manner. For instance, the kitchen area has several spotlights which
helps illuminates the menu items. It also helps the baristas to prepare the drinks in dimly lit
situations. The kitchen which also acts as a counter, needs to be brightly lit up to allow
customers to better view the menu and so on. Surrounded in conjunction with curtain walls,
the kitchen/counter area is brightlylit up by natural and artificial lightings to serve for both a
practical and aestheticmanner.
Figure 3.44 Dining Spaces Illuminated with Warm Spotlights. (Hong,2016)
The middle area ofthe café which houses the diningspaces are also lit up byartificial lightings
throughout most of the day. Although surrounded by curtain walls and having several
openings nearbylike the stairs,it is still not enough to provide a fair daylightingdistribution.
Though with artificial lights,it can achieve the desired daylightingresults with a warm mood
as a bonus.
Figure 3.45 Warm Mood Created by Artificial Lightings. (Wong,2016)
72
To provide a better level of illumination,the interior finishes plays a huge role. For instance,
the slightly tinted glass of the curtain walls decreases the glaring issues when sunlight
penetrates the interior spaces of the building. Thus, helping the user feel more comfortable
gazing outside. Moreover, the natural skylight from the rooftop decreases the usage of
artificial lightings to achieve the sufficient daylight illumination of the interior spaces. With
the inclusion of minimal artificial lightings, the interior spaces can be illuminated to desired
levels and yet still achieve the mood and aestheticthat was aimed for.Thus,creatinga warm,
natural and cozy feelingto the users.
73
4.0 ACOUSTICS
4.1 PRECEDENT STUDY
4.1.1 INTRODUCTION
Figure 4.01 Sky City and the Auckland Skyline. (http://vizts.com/901-2/)
Figure 4.02 Site of Sky City in Auckland. (Google Maps)
74
In this precedent study, the Sky City Casino and Conference Centre in Auckland was
undergoing a renovation, an existing conference room is to be converted into a bar/
nightclub. The Marshall Day Acoustics were engaged in order to design a sound
insulation device to mitigate the noise transmission from the bar to the hotel suites
which are located on level 4, one floor above the bar’s new location which is on level
3. Complaints were made previously from the hotel as noise can be heard from the
conference room when amplified music was being played. After performing noise
reduction measurements before and after the renovation, it was considered that the
concrete slab between the hotel rooms and conference space was the primary
medium for sound transmission and so design solutions will be focus on the medium.
4.1.2 OBJECTIVES AND ISSUES
Since that the concrete slab was the cause of the noise transmission between the two
floors, an acoustic ceiling is design in order to mitigate and minimize the noise
transmission that affects the concrete slab. This had to be achieved with a buildable
and affordable solution that could accommodate the services and architectural issues
that are existing. The existing structure of the building was remaining and as such
there is no leeway for structural changes. The immediate obvious solution is to achieve
a high degree of transmission loss at low frequencies from the planned acoustic ceiling
as any mid-high frequency components of the music would be attenuated through the
structure itself and hence it was merely a low frequency problem at 63 Hz - 125 Hz.
4.1.3 EXISTING CONSTRUCTION
Figure 4.03 Hotel Layout.
75
All of the hotel suites are located one floor above the converted conference space and
they all share the same floor slab. The shared ceiling floor is 120 Hibond which gives
an average concrete thickness of 90 mm. The ceilings in the conference room was a
perforated acoustic ceiling and the walls on both the hotel levels and the conference
room were made of lightweight drywall construction.
Figure 4.04 Lightweight Drywall.
Figure 4.05 Perforated Acoustic Ceiling Tiles.
76
4.1.4 PRE-RENOVATION MEASUREMENTS
Measurements were carried out in the conference room before renovation to
determine the sound insulation provided by the existing structure.
Audio equipment were used to generate the high noise levels required. Independently,
pink noise and a dance music sample were amplified to a reverberant level of L𝑒𝑞 95-
97 dBA in the conference room. Pink noise and dance music samples were used to
measure the level of noise received in the five hotel suites on Level 4.
Reverberant levels of the pink noise generated in the conference room were :
● L𝑒𝑞 105 dB @ 63 Hz
● L𝑒𝑞101 dB @ 125 Hz
In suite 5, the pink noise was barely audible above the ambient noise levels. In Fact
the bass beat of the dance music was barely detectable hence measurements in this
room were discarded.
All measurements here were slightly affected by the traffic from the surrounding
neighbourhood and nearby construction noise. The table below summarizes the
results obtained.
Figure 4.06 Pre-Renovation Measured Noise Levels.
77
4.1.5 DESIGN STANDARD
Sound received from dance music and live bands normally consist of a rhythmic low
frequency tone. When this noise is clearly identifiable from above the ambient noise
levels in a bedroom than it is likely to be a nuisance to the occupants. As such, the
ambient noise levels in the hotel suites were used as a benchmark for a design
criterion. It is clear that it would not be practically possible to achieve acceptable noises
in all the hotel suites from the previous measurement. Hence, the objective is to
mitigate as much of the noise as practically possible.
4.1.6 FINAL TREATMENT
An acoustic ceiling is to be incorporated into the architectural ceiling and would be
suspended 2 meters below the bottom of the slab in order to avoid the structural
steelwork with the construction as follow:
● 120 mm Hibond slab;
● 2000 mm air gap accommodating structural steelwork and services;
● 3 layers of R1.8, 75 mm Pink Batts insulation
● Ceiling consisting of 1 layer 21 mm plywood and 2 layers 13 mm Gib Noiseline
suspended on spring hangers
4.1.7 COMMISSIONING MEASUREMENTS
Sound insulation performance of the acoustic ceiling was measured in the same way
as the pre-renovation measurements once the refitting is complete. The table below
summarizes the results:
78
Figure 4.07 CommissioningMeasured Noise Levels.
A comparison with the before and after measurements gives an indication that an
improved sound insulation has been achieved with the acoustic ceiling.
Low frequency noise level in the hotel room has a moderate increase from the noise
cause by the bar. However, there was no change to the A-weighted noise levels in the
rooms. Dance music was played at high levels in the bar and a moderately low level
of low frequency was detectable in the hotel suites.
4.1.8 DISCUSSION AND CONCLUSION
The sound insulation performance resulting from the measurement has an
improvement from the previous measurement due to the installation of the acoustic
ceiling but it was not as great as predicted theoretically. This shortcoming of
performance was already expected and most likely cause by the nature of the field
conditions, possible material variations in the building products and also some flanking
transmission through other paths.
The level of noise generated by the bar need to be limited to approximately 95 dB at
63 Hz and 92 dB at 125 Hz in order to control the transmission of low frequency noise
and this in turn would limit the number of complaints received. As a conclusion, the
bar/night club has now been undergoing operation successfully for several months
since the installation. As predicted, they were occasional complaints made by the
guest staying at the hotel in rooms above which are most affectedby the bar. However,
the overall result is such that the acoustic ceiling design is considered to be successful
in being a sound insulation.
79
4.2 CASE STUDY
4.2.1 SITE AND ZONING
NOISE IDENTIFICATION
TYPE OF EXTERNAL SOUND SOURCE DESCRIPTION
The macro site is surrounded by main roads
which are heavily used by cars throughout the
day (highlighted red). However, due to the
location of the site noise factor from these main
roads are almost unnoticeable. As for the micro
site, the surrounding roads of the site is used
heavily by many types of vehicles including
lorries and trucks, and produce a high level of
noise. However, the noise is reduced as the site
is enclosed in an area, and the building
surrounded by other adjacent buildings
dampening outdoor noise and keeping noise
pollution to a minimum.
The neighboring buildings, although vary in
activities do not serve any real noise intrusion to
the building, as the operational hours do not
coincidewith many of the activities. For instance,
church activities on one side is normally
conducted before or after the café operation
hours and the restaurant is always constantly low
on noise volume.
One area in which that the café receives external
noise is located at the back, where the air
condition condensers are located. Fully
functional during opening hours, they constantly
blare out bland humming tone at up to 54dB
which is most obvious at the back of the café.
Towards the front the sound is eliminated from
the brick wall.
80
SITE ZONING
Figure 4.08 Gridlines WhichAre Used to Collect Acoustic Data.
The gridline, established together with the lighting data collection grid, is also used to
gather acoustic measurements in and around the building, with a 1.5m spacing in
between each grid point, forming a total of 49 grid points.
81
4.2.2 DATA TABULATION AND ANALYSIS
*The acoustics were recorded and measured at 1.5m.
ACOUSTIC DATA
UNIT: DECIBEL (dB)
HEIGHT: 1.5M (STANDING)
Figure 4.09 Non-Peak Acoustic Reading.
Figure 4.10 Non-Peak Acoustic Reading.
Non Peak Hour 11.30AM - 12.00PM
GRID A B C D E F G H I J K
1 60.3 61.3 62.9 61.5 61.4 62.3 61.3 62.8 64.3
2 60.4 60.7 60.2 66.7 61.3 61.7 61.8 62.7 63.9
3 61.1 62 68.3 62 68.4 62.7 63.2 63.3 63.4 67.8 71.2
4 60.6 70.4 72 63.2 64.2 66.6 65.3 65.4 66.2 68.2 69.2
5 58 58.3 60.4
6 60 59 63.5
7 60 59.4 58.6
Non Peak Hour 11.30AM -
12.00PM
GRI
D A B C D E F G H I J K
1
1.07E
-06
1.35E
-06
1.95E
-06
1.41E
-06
1.38E
-06
1.69E
-06
1.34E
-06
1.90E
-06
2.69E
-06
2
1.10E
-06
1.17E
-06
1.05E
-06
4.67E
-06
1.34E
-06
1.47E
-06
1.51E
-06
1.86E
-06
2.45E
-06
3
1.29E
-06
1.58E
-06
6.76E
-06
1.58E
-06
6.91E
-06
1.86E
-06
2.08E
-06
2.13E
-06
2.18E
-06
6.02E
-06
1.31E
-06
4
1.15E
-06
1.10E
-06
1.58E
-05
2.08E
-06
2.63E
-06
4.57E
-06
3.38E
-06
3.46E
-06
4.16E
-06
6.60E
-06
8.31E
-06
5
6.30E
-07
6.76E
-07
1.10E
-06
6
1.00E
-06
7.94E
-07
2.24E
-06
7
1.00E
-06
8.71E
-07
7.24E
-07
82
Figure 4.11 Peak Acoustic Reading.
Figure 4.12 Peak Acoustic Reading.
Peak Hour 5pm-5.15pm
GRID A B C D E F G H I J K
1 65 63 67 69 69 68 67 67 65
2 65 64 66 71 71 67 64 66 64
3 66 68 65 66 66 65 69 66 65 69 75
4 68 70 67 71 70 68 67 68 67 74 78
5 70 71 77
6 72 73 76
7 64 65 75
Peak Hour 5pm-
5.15pm
GRI
D A B C D E F G H I J K
1
3.16E
-06
1.99E
-06
5.01E
-06
7.94E
-06
7.94E
-06
6.30E
-06
5.01E
-06
5.01E
-06
3.16E
-06
2
3.16E
-06
2.51E
-06
3.98E
-06
1.25E
-05
1.25E
-05
5.01E
-06
2.51E
-06
3.98E
-06
2.51E
-06
3
3.98E
-06
6.30E
-06
3.16E
-06
3.98E
-06
3.98E
-06
3.16E
-06
7.94E
-06
3.98E
-06
3.16E
-06
7.94E
-06
3.16E
-05
4
6.30E
-06
1.00E
-05
5.01E
-06
1.25E
-05
1.00E
-05
6.30E
-06
5.01E
-06
6.30E
-06
5.01E
-06
2.51E
-05
6.30E
-05
5
1.00E
-05
1.25E
-05
5.01E
-05
6
1.58E
-05
1.99E
-05
3.98E
-05
7
2.51E
-06
3.16E
-06
3.16E
-05
83
Figure 4.13 Non-Peak Sum Intensity and Sound Intensity Levels (BELOW)
Sum of Intensity for each zone, I
Non Peak Hour 11.30AM - 12.00PM
GRID A B C D E F G H I J K
1
2 9.62E-05
3 2.22E-05
4
5
6 9.03E-06
7
Sound Intensity level (SIL) per zone
Non Peak Hour 11.30AM - 12.00PM
GRID A B C D E F G H I J K
1
2 79.83
3 73.46
4
5
6 69.56
7
84
Figure 4.14 Peak Sum Intensity and Sound Intensity Levels (BELOW)
Sum of Intensity for each zone, I
Peak Hour 5pm-5.15pm
GRID A B C D E F G H I J K
1
2 2.00E-04
3 1.28E-04
4
5
6 1.86E-04
7
SIL Peak Hour 5pm-5.15pm
GRID A B C D E F G H I J K
1
2 83.01
3 81.07
4
5
6 82.7
7
85
INTERPRETATION AND ANALYSIS
Observation 1
There is a peak of 70.4dB in grid B4.
Discussion and Analysis 1
Grid B4 is situated near the barista counter where the making of coffee and the
machinery sound are produced.
Observation 2
There is a significant rise in decibels in grid k3 and k4.
Discussion and Analysis 2
There is a backdoor adjacent between grid k3 and k4. Outside the perimeter are the
placement of the outdoor condensers which are required to operate the air conditioner
of the café and the nearby restaurant. The rise in decibels in grid k3 and k4 are due to
the sound coming from the outdoor spaces.
Observation 3
During the non-peak hour (11.30am), Grid B4 and C4 can be seen having a
significantly higher decibel when compared to the rest.
Discussion and Analysis 3
The reason it has a higher decibel reading could be due to the placement of the cake
display cabinet/fridge. Another reason could be during the time of measurement, the
Ice blender located in the kitchen area is being used.
86
Observation 4
During the peak hour (6.00pm), a rise of decibels in the collected data is observed.
Discussion and Analysis 4
The data collected shows a rise in decibels during the peak hour. Working adults and
university students hang out in the café after classes and work. There were more
people in the café at the time, chatting, talking and discussing on things. Thus, the
higher reading. Moreover, during the peak hour, music was even played in the
background. No music was playing in the background during the non-peak hour visit.
Observation 5
During the peak hour (6.00pm), a rise of decibels in Grid B5, B6, C5, C6 and C7 are
collected and measured.
Discussion and Analysis 5
The higher decibels in Grid B5, B6, C5, C6 and C7 are due to the coffee machines,
grinders and etc. working to meet the demand of the customers during the peak hour
of 6pm.
87
4.2.3 MATERIAL SPECIFICATION
ZONE A (DINING)
Component Material Colour Surface
Finish
Absorpti
on
Coefficie
nt
(500 Hz)
Abso
rptio
n
Coeff
icient
(200
0 Hz)
Surfa
ce
Area
(m²)
Ceiling Metal deck Black Matte 0.7 0.86 68.0
Wall Brick wall Brown Matte 0.02 0.02 10.94
Painted Wall Black Matte 0.02 0.02 9.05
88
Curtain Glass wall Transparent Glossy 0.04 0.03 107.5
Floor Concrete Grey Matte 0.05 0.05 79.8
Door Metal Frame with glass panel Black
/transparent
Matte/
Glossy
0.04 0.03 2.5
89
Stairs Steel Black Matte 0.7 0.86 19.8
Frosted Glass Translucent Matte 0.04 0.03 19.5
90
Furniture Timber Chair Brown Glossy 0.22 0.38 0.8x24
= 19.2
Timber Stool Dark
Brown
Matte 0.22 0.38 0.7x8
= 5.6
Timber table painted Brown Matte 0.22 0.38 0.36 x 10
= 3.6
91
Leather sofa Black Matte 0.28 0.28 2.4
Reclaimed timber table Brown Matte 0.22 0.38 1.1
Reclaimed palette coffee table Brown Matte 0.22 0.38 0.9
92
ZONE B (KITCHEN)
Ceiling Concrete Grey Matte 0.05 0.05 22.5
Wall Brick wall Brown Matte 0.02 0.02 29.2
Floor Concrete Grey Matte 0.05 0.05 17.1
93
Window Clear Glass Transparent Glossy 0.04 0.03 23.7
Furniture Timber Stool Dark
Brown
Matte 0.22 0.38 2.8
Reclaimed timber table Brown Matte 0.22 0.38 1.1
94
ZONE C (SERVICE)
Ceiling Metal deck Black Matte 0.7 0.86 6.65
Wall Brick wall Brown Matte 0.02 0.02 1.72
Curtain Glass wall Transparent Glossy 0.04 0.03 31.3
95
Floor Concrete Grey Matte 0.05 0.05 8.4
96
4.2.4 FIXTURES AND SPECIFICATIONS
Type of Sound Source Product
Model
Units and zone
Placement
Wattage Voltage Noise
Level
Acson Wall
Mounted Split
G series R22
Model
1 unit at Zone B 880 220 52dB
York Floor
Ceiling
Convertible
Deluxe R410A
1 unit at Zone C 1130 220 55dB
JAMAJKA
1.3W
1 unit at Zone A 1300 220 52dB
Xs-160yx Glass
Top Deep
Freezers Mini
Ice Cream
Display
Freezer
1 unit at Zone A - 220 50dB
Berjaya
Counter
Chiller
CC2100-S
1 unit at Zone B 618 220 50dB
97
KDK Ceiling
Fan
KY14X8MC
-3 units at Zone
A
-1 unit at Zone B
760 230 45dB
Phillips Rice
Cooker
HD3027
1 unit at Zone B 650 220 49dB
Anfim
Caimano
Coffee
Grinder
1 unit at Zone B 450 220 80dB
Sharp
Countertop
Microwave
Oven 0.9 CU.
FT. 900W
1 unit at Zone B 900 120 58dB
98
Keesvanderwe
stern Mirage
1 unit at Zone B 3600 220 85dB
APPLIANCES INTENSITY CALCULATION
Source Noise Level (dB) Intensity, I
Acson Wall Mounted Split G
series R22 Model
52 1.5849E-07
York Floor Ceiling Convertible
Deluxe R410A
55 3.1623E-07
JAMAJKA 1.3W 52 1.5849E-07
Xs-160yx Glass Top Deep
Freezers Mini Ice Cream
Display Freezer
50 0.0000001
Berjaya Counter Chiller
CC2100-S
50 0.0000001
KDK Ceiling Fan KY14X8MC 45 3.1623E-08
Phillips Rice Cooker HD3027 49 7.9433E-08
Anfim Caimano Coffee Grinder 80 8.71E-07
Sharp Countertop Microwave
Oven 0.9 CU. FT. 900W
58 0.0004
Keesvanderwestern Mirage 85 3.1623E-04
99
Combined Appliances at Zone A
Source Quantity Intensity Total Intensity
KDK Ceiling Fan
KY14X8MC
3 3.1623E-08 9.4869E-08
Xs-160yx Glass Top
Deep Freezers Mini Ice
Cream Display Freezer
1 0.0000001 0.0000001
JAMAJKA 1.3W 1 1.5849E-07 1.5849E-07
Grand Total Intensity 3.5336E-07
100
Combined Appliances at Zone B
Source Quantity Intensity Total Intensity
Acson Wall Mounted
Split G series R22
Model
1 1.5849E-07 1.5849E-07
Berjaya Counter
Chiller CC2100-S
1 0.0000001 0.0000001
Phillips Rice Cooker
HD3027
1 7.9433E-08 7.9433E-08
Anfim Caimano Coffee
Grinder
1 8.71E-07 8.71E-07
Sharp Countertop
Microwave Oven 0.9
CU. FT. 900W
1 0.0004 0.0004
Keesvanderwestern
Mirage
1 3.1623E-04 3.1623E-04
Grand Total Intensity 7.1745E-04
101
Combined Appliances at Zone C
Source Quantity Intensity Total Intensity
York Floor Ceiling
Convertible Deluxe
R410A
1 3.1623E-07 3.1623E-07
Grand Total Intensity 3.1623E-07
102
APPLIANCES SIL CALCULATION
Sound Intensity Level (SIL) by Zone
Zone Intensity, I Sound Intensity, SIL
A 3.5336E-07 55.48
B 7.1745E-04 88.56
C 3.1623E-07 55
Sound Intensity Level (SIL) of entire space
Zone Intensity, I
A 3.5336E-07
B 7.1745E-04
C 3.1623E-07
Entire Space 7.1813E-04
𝑆𝐼𝐿 = 10 𝐿𝑜𝑔 (
𝐼
1𝑥10−12
)
𝑆𝐼𝐿 = 10 𝐿𝑜𝑔 (
7.1813𝑥10−4
1𝑥10−12 )
𝑆𝐼𝐿 = 88.56𝑑
Hence, the total SIL of the space is 88.56 dB
103
ANALYSIS
Figure 4.15 Noise Criteriafor Acoustic Environment in Building Interiors.
Figure 4.16 Sound Decibel Table.
104
According to Academic Resource Centre of Illinois Institute of Technology, restaurants
or cafes have a noise criteria ranging from 48-52 dB. Greyskymorning cafe has a total
Sound Intensity of 88.56 dB, which almost doubles the amount of acceptable sound
intensity in the build environment probably due to the machinery being used in the
cafe. As a comparison, Noise that exceeds 80dB is considered as too loud for normal
conversation to be held and would be a nuisance to users.
105
4.2.5 SOUND REDUCTION INDEX (SRI) CALCULATION
CEILING
Component Material Colour
Surface
Finish
Surface
Area(m2
)
SRI
Transmission
Coefficient, T
ST
Ceiling Metal
deck
Black Matte 74.7 50 0.00001 0.000747
Concrete Grey Matte 22.5 43 0.00005 0.001125
TotalSurface Area 97.2 TotalST 0.001872
T =
1
𝑎𝑛𝑡𝑖𝑙𝑜𝑔 (
𝑆𝑅𝐼
10
)
Tav =
𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛
𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎
=
0.001872
97.2
= 0.00002
SRI = 10 Log10
1
𝑇𝑎𝑣
= 10 Log10
1
0.00002
= 47 dB
106
FLOOR
Component Material Colour
Surface
Finish
Surface
Area(m2
)
SRI
Transmission
Coefficient, T
ST
Floor Concrete Black Matte 105.3 50 0.00001 0.001053
TotalSurface Area 105.3 TotalST 0.001053
T =
1
𝑎𝑛𝑡𝑖𝑙𝑜𝑔 (
𝑆𝑅𝐼
10
)
Tav =
𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛
𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎
=
0.001053
105.3
= 0.00001
SRI = 10 Log10
1
𝑇𝑎𝑣
= 10 Log10
1
0.00001
= 50 dB
107
Figure 4.17 Plan with Indications for SRI Calculations.
108
WALL A
Component Material Colour
Surface
Finish
Surface
Area
(m2
)
SRI
Transmission
Coefficient, T
ST
Wall Curtain
Glass Wall
Transparent Glossy 19.2 37 0.0002 0.00384
Door Metal
Frame w/
Glass
Panel
Black/
Transparent
Matte/
Glossy
2.8 37 0.0002 0.00056
TotalSurface Area 22 TotalST 0.0044
T =
1
𝑎𝑛𝑡𝑖𝑙𝑜𝑔 (
𝑆𝑅𝐼
10
)
Tav =
𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛
𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎
=
0.0044
22
= 0.0002
SRI = 10 Log10
1
𝑇𝑎𝑣
= 10 Log10
1
0.0002
= 37 dB
109
WALL B
Component Material Colour
Surface
Finish
Surface
Area
(m2
)
SRI
Transmission
Coefficient, T
ST
Wall Curtain
Glass Wall
Transparent Glossy 52.2 37 0.0002 0.01044
Concrete Grey Matte 3.4 43 0.00005 0.0002
Door Metal
Frame w/
Glass
Panel
Black/
Transparent
Matte/
Glossy
2.8 37 0.0002 0.00056
Column Concrete Grey Matte 4.8 43 0.00005 0.00024
TotalSurface Area 63.2 TotalST 0.01144
T =
1
𝑎𝑛𝑡𝑖𝑙𝑜𝑔 (
𝑆𝑅𝐼
10
)
Tav =
𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛
𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎
=
0.01144
63.2
= 0.00018
SRI = 10 Log10
1
𝑇𝑎𝑣
= 10 Log10
1
0.00018
= 37 dB
110
WALL C
Component Material Colour
Surface
Finish
Surface
Area
(m2
)
SRI
Transmission
Coefficient, T
ST
Wall Brick Wall Brown Matte 11.57 45 0.00003 0.00035
Window Clear
Glass
Transparent Glossy 3 37 0.0002 0.0006
TotalSurface Area 14.57 TotalST 0.00095
T =
1
𝑎𝑛𝑡𝑖𝑙𝑜𝑔 (
𝑆𝑅𝐼
10
)
Tav =
𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛
𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎
=
0.00095
14.57
= 0.00007
SRI = 10 Log10
1
𝑇𝑎𝑣
= 10 Log10
1
0.00007
= 42 dB
111
WALL D
Component Material Colour
Surface
Finish
Surface
Area
(m2
)
SRI
Transmission
Coefficient, T
ST
Wall Brick Wall Brown Matte 5.1 45 0.00003 0.00015
Window Clear
Glass
Transparent Glossy 10.5 37 0.0002 0.0021
TotalSurface Area 15.6 TotalST 0.00225
T =
1
𝑎𝑛𝑡𝑖𝑙𝑜𝑔 (
𝑆𝑅𝐼
10
)
Tav =
𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛
𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎
=
0.00225
15.6
= 0.00014
SRI = 10 Log10
1
𝑇𝑎𝑣
= 10 Log10
1
0.00014
= 39 dB
112
WALL E
Component Material Colour
Surface
Finish
Surface
Area
(m2
)
SRI
Transmission
Coefficient, T
ST
Wall Brick Wall Brown Matte 1.8 45 0.00003 0.00005
Window Clear
Glass
Transparent Glossy 3 37 0.0002 0.0006
Door Metal
Frame w/
Glass
Panel
Black/
Transparent
Matte/
Glossy
2.8 37 0.0002 0.00056
TotalSurface Area 7.6 TotalST 0.00121
T =
1
𝑎𝑛𝑡𝑖𝑙𝑜𝑔 (
𝑆𝑅𝐼
10
)
Tav =
𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛
𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎
=
0.00121
7.6
= 0.000159
SRI = 10 Log10
1
𝑇𝑎𝑣
= 10 Log10
1
0.000159
= 38 dB
113
WALL F
Component Material Colour
Surface
Finish
Surface
Area
(m2
)
SRI
Transmission
Coefficient, T
ST
Wall Glass
Curtain
Wall
Transparent Glossy 43.9 37 0.0002 0.00878
Brick Wall Brown Matte 3.9 45 0.00003 0.00012
Column Concrete Grey Matte 2 43 0.00005 0.0001
TotalSurface Area 49.8 TotalST 0.009
T =
1
𝑎𝑛𝑡𝑖𝑙𝑜𝑔 (
𝑆𝑅𝐼
10
)
Tav =
𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛
𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎
=
0.009
49.8
= 0.00018
SRI = 10 Log10
1
𝑇𝑎𝑣
= 10 Log10
1
0.00018
= 37 dB
114
WALL G
Component Material Colour
Surface
Finish
Surface
Area(m2
)
SRI
Transmission
Coefficient, T
ST
Wall Brick Wall Brown Matte 17.9 45 0.00003 0.000537
TotalSurface Area 17.9 TotalST 0.000537
T =
1
𝑎𝑛𝑡𝑖𝑙𝑜𝑔 (
𝑆𝑅𝐼
10
)
Tav =
𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛
𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎
=
0.000537
17.9
= 0.00003
SRI = 10 Log10
1
𝑇𝑎𝑣
= 10 Log10
1
0.00003
= 45 dB
115
WALL H
Component Material Colour
Surface
Finish
Surface
Area
(m2
)
SRI
Transmission
Coefficient, T
ST
Wall Glass
Curtain
Wall
Transparent Glossy 7 37 0.0002 0.0014
Brick Wall Brown Matte 10.1 45 0.00003 0.0003
Door Metal
Frame w/
Glass
Panel
Black/
Transparent
Matte/
Glossy
2.8 37 0.0002 0.00056
TotalSurface Area 19.9 TotalST 0.00226
T =
1
𝑎𝑛𝑡𝑖𝑙𝑜𝑔 (
𝑆𝑅𝐼
10
)
Tav =
𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛
𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎
=
0.00226
19.9
= 0.000114
SRI = 10 Log10
1
𝑇𝑎𝑣
= 10 Log10
1
0.000114
= 39 dB
116
WALL I
Component Material Colour
Surface
Finish
Surface
Area(m2
)
SRI
Transmission
Coefficient, T
ST
Wall Glass
Curtain
Wall
Transparent Glossy 15.4 37 0.0002 0.003
Brick Wall Brown Matte 2.2 45 0.00003 0.000066
TotalSurface Area 17.6 TotalST 0.003066
T =
1
𝑎𝑛𝑡𝑖𝑙𝑜𝑔 (
𝑆𝑅𝐼
10
)
Tav =
𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛
𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎
=
0.003066
17.6
= 0.000174
SRI = 10 Log10
1
𝑇𝑎𝑣
= 10 Log10
1
0.000174
= 38 dB
117
SOUND TRANSMISSION BETWEEN INTERIOR AND EXTERIOR
Due to the nature of our site, certain areas were inaccessible. Therefore, we only
managed to obtain the Exterior sound levels of certain outdoor spaces.
Using the formula:
Exterior sound levels – SRI of the respective surface = Sound Transmission of
respective surface
Through this formula, we are able to obtain the Sound Transmission of the given
surfaces so that we may identify its percentage in which it transmits.
Figure 4.18 Plan with Indications of The Measured Outdoor Acoustic Levels.
118
Wall A
Exterior sound levels – SRI of the respective surface = Sound Transmission of respective surface
54 dB – 37 dB = 17 dB
17𝑑𝐵
54𝑑𝐵
x 100% = 31%
Wall E
73 dB – 38 dB = 35 dB
35𝑑𝐵
73𝑑𝐵
x 100% = 48%
Wall F
62 dB – 37 dB = 25 dB
25𝑑𝐵
62𝑑𝐵
x 100% = 40%
Average of Percentages
31+48+40
3
= 39.7%
ANALYSIS
Without the remaining measurements for the other surfaces, it’s quite hard to draw a
proper conclusion. However, due to the similarity in the types of spaces outside as
well as the materiality of the which create a very uniform Sound Reduction Index
throughout the overall building, it is safe to assume that the average of the percentages
would be roughly the same. Overall the buildings surface allows more than 50 percent
of the exterior sound found on the site. This is most likely due to the large amounts of
glass found throughout the site.
119
4.2.6 REVERBERATION TIME
1
120
2
121
4.2.7 ACOUSTIC ANALYSIS AND EVALUATION
The recommended Noise Criteria for a café, referring to AS/NZS 2107:2000, is in the
region of 45-50dBA. The recommended reverberation time for a café should also be
in the proximity of 0.4-0.6s, as stated by AS/NZS 2107:2000. However, during our
testing and analysis the sound levels consistently breach the 70-80 dBA readings. To
put that into perspective, the human ear works optimally at the 48-72 dBA range.
Acoustic comfort in a building or space is very important for the users to feel
comfortable and be able to work and play efficiently in that space. Acoustic levels also
play a very important role in the balance and effect on the psychological and
physiological well-being of the user.
Thankfully, the building does not suffer from major acoustical disturbances from the
exterior as the road networks and isolation of the site work in favour to dampen
acoustic levels. The café does, however, receive some noise at the back portion in via
the noise generated by the air conditioning systems. In the interiors of the café, the
main acoustical noises are generated from the usage of Coffee Machines as well as
Kitchen Appliances that are all important to serve customers. The café tackles these
situations by placing the kitchen in a corner, away from the users and sound direction
and not placing any seats or usage space within close proximity of the back portion of
the café.
The material usage, namely steel, bricks and wood also help in reducing the acoustical
levels, with acoustic absorption characteristics that ensure acoustic acceptability of
space. The café may improve its acoustic absorption characteristics further by using
more soft materials which aid in absorbing sound.
122
5.0 CONCLUSION
After conducting a detailed analysis on the site and gaining a newfound understanding
on lighting and acoustic properties and functions, many conclusions may be made.
Starting with the lighting design, our observations as well as calculations came to the
conclusion that the building is able to receive sufficient amounts of light via natural
lighting with little extra aid from artificial lights throughout all zones studied as
stipulated by MS 1525. Although it may be recommended that the café adopt some
shading properties in the form of shading devices as at times during our analysis we
have come to find that the building, especially the areas close to the walls may receive
too much light and heat, causing discomfort to the users.
As for the acoustic properties, the building is exceptional in that it takes advantage of
it’s infill nature to reduce acoustic disturbance from the outdoors. The relative isolation
of the café and entire building itself also contributes heavily to the reduction or
prevention of major acoustic hazards from penetrating anywhere close to the café.
Internally the café suffers from slight acoustic hazards especially in and around the
kitchen area and the back part of the café. As the noise origins are unavoidable it can
be recommended that the café implement the usage of more soft materials such as
pillows or carpets around the café to improve noise absorption as well as maybe even
purchasing and using sound masking speakers that not only serve to absorb noise,
but also play any form of music that may aid to the acoustical comfort of the customers.
An example of such a product is the XOUNT 360, widely used and available in the
market.
Overall, this is a project that has brought us, all the members, new and improved
knowledge about lighting and acoustics that are related to a building. Through this
project we are also able to improve our bond from working together which will help
propel us to improve ourselves as well. Finally the lessons learnt from this assignment
would be crucial and important to the application and design of subsequent
assignments relating to architecture that any of us may partake in the future.
123
APPENDIX
124
125
126
127
128
129
130
131
132
133
REFERENCES
1) "Best Nursing Schools In The US | Collegeatlas.Org". Collegeatlas.org. N.p.,2016. Web. 6 Nov. 2016.
2) "Room Acoustic Measurements 101 - Acoustic Frontiers". Acousticfrontiers.com. N.p., 2016. Web.
7 Nov. 2016.
3) "Audio & Acoustic Measurement Instruments". Nti-audio.com. N.p., 2016. Web. 7 Nov. 2016.
4) "LUTRON ELECTRONIC ENTERPRISE CO., LTD.". Lutron.com.tw. N.p., 2016. Web. 7 Nov. 2016.
5) "Measuring Light Levels | Sustainability Workshop". Sustainabilityworkshop.autodesk.com. N.p.,
2016. Web. 7 Nov. 2016.
6) "Daylight Saving Time Dates For Malaysia – Kuala Lumpur Between 2010 And 2019".
Timeanddate.com. N.p., 2016. Web. 7 Nov. 2016.
7) "Definitions Of Lux, Lumens & Watts For Lighting | GREEN BUSINESS LIGHT".
Greenbusinesslight.com. N.p., 2016. Web. 7 Nov. 2016.
8) "Daylight Factor | Daylighting Pattern Guide". Patternguide.advancedbuildings.net. N.p., 2016.
Web. 7 Nov. 2016.
9) "Sound Absorption". Acoustical Surfaces. N.p., 2016. Web. 7 Nov. 2016.
10) "Sound Absorption Materials | Soundproof Cow". Soundproof Cow. N.p., 2016. Web. 7 Nov. 2016.
11) "Soundproofing Vs Sound Absorbing - What's The Difference? - Acoustical Surfaces". Acoustical
Surfaces. N.p., 2016. Web. 7 Nov. 2016.
12) "The Daylight Factor - Designing Buildings Wiki". Designingbuildings.co.uk. N.p.,2016. Web. 7 Nov.
2016.

More Related Content

What's hot

Building Science 1 (Project 1)
Building Science 1 (Project 1)Building Science 1 (Project 1)
Building Science 1 (Project 1)Soh Shing
 
Building Science Report
Building Science ReportBuilding Science Report
Building Science ReportLiew Hong Zhi
 
Light report compiled
Light report compiledLight report compiled
Light report compiledPreston Liew
 
Report of Geographer Cafe (Methods of Documentation and Measured Drawings)
Report of Geographer Cafe (Methods of Documentation and Measured Drawings)Report of Geographer Cafe (Methods of Documentation and Measured Drawings)
Report of Geographer Cafe (Methods of Documentation and Measured Drawings)AlexSiv03
 

What's hot (8)

Building Science 1 (Project 1)
Building Science 1 (Project 1)Building Science 1 (Project 1)
Building Science 1 (Project 1)
 
Final report
Final reportFinal report
Final report
 
Sound final
Sound finalSound final
Sound final
 
Building Science Report
Building Science ReportBuilding Science Report
Building Science Report
 
Light report compiled
Light report compiledLight report compiled
Light report compiled
 
Bscience
BscienceBscience
Bscience
 
Report
ReportReport
Report
 
Report of Geographer Cafe (Methods of Documentation and Measured Drawings)
Report of Geographer Cafe (Methods of Documentation and Measured Drawings)Report of Geographer Cafe (Methods of Documentation and Measured Drawings)
Report of Geographer Cafe (Methods of Documentation and Measured Drawings)
 

Similar to Building science 2 arc3413uyiyuiy 2

Building Science II
Building Science IIBuilding Science II
Building Science IIIvy Yee
 
FINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdf
FINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdfFINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdf
FINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdfOctonio Octonio
 
Lighting and Acoustic Performance - Absolute Coffee
Lighting and Acoustic Performance - Absolute CoffeeLighting and Acoustic Performance - Absolute Coffee
Lighting and Acoustic Performance - Absolute CoffeeOctonio Octonio
 
Building Science II
Building Science IIBuilding Science II
Building Science IIjernjack
 
Final bscience report compilation
Final bscience report compilationFinal bscience report compilation
Final bscience report compilationkerneng
 
Building Science 2
Building Science 2Building Science 2
Building Science 2Gertrude Lee
 
B.science report 1.2
B.science report 1.2B.science report 1.2
B.science report 1.2Elaine Bong
 
Building Science Project 1 : Lighting & Acoustic Performance Evaluation & Design
Building Science Project 1 : Lighting & Acoustic Performance Evaluation & DesignBuilding Science Project 1 : Lighting & Acoustic Performance Evaluation & Design
Building Science Project 1 : Lighting & Acoustic Performance Evaluation & DesignAdibah Awang
 
Building Science II: Lighting Report
Building Science II: Lighting ReportBuilding Science II: Lighting Report
Building Science II: Lighting ReportEe Dong Chen
 
Architectural conservation arc3413 king street penang
Architectural conservation arc3413 king street penangArchitectural conservation arc3413 king street penang
Architectural conservation arc3413 king street penangGary Yeow
 
Building Science II Report
Building Science II ReportBuilding Science II Report
Building Science II ReportVansC
 
Acoustic Analysis Project 1
Acoustic Analysis Project 1Acoustic Analysis Project 1
Acoustic Analysis Project 1J-Sern Phua
 
Auditorium: A Case Study on Acoustic Design Report
Auditorium: A Case Study on Acoustic Design ReportAuditorium: A Case Study on Acoustic Design Report
Auditorium: A Case Study on Acoustic Design Reportjisunfoo
 
bstructureproject2-150706142716-lva1-app6892.pdf
bstructureproject2-150706142716-lva1-app6892.pdfbstructureproject2-150706142716-lva1-app6892.pdf
bstructureproject2-150706142716-lva1-app6892.pdfJ.j. Hayashi
 
Building Structures Report
Building Structures ReportBuilding Structures Report
Building Structures ReportJoanne Yunn Tze
 

Similar to Building science 2 arc3413uyiyuiy 2 (20)

Building Science II
Building Science IIBuilding Science II
Building Science II
 
FINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdf
FINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdfFINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdf
FINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdf
 
Lighting and Acoustic Performance - Absolute Coffee
Lighting and Acoustic Performance - Absolute CoffeeLighting and Acoustic Performance - Absolute Coffee
Lighting and Acoustic Performance - Absolute Coffee
 
Building Science II
Building Science IIBuilding Science II
Building Science II
 
Final bscience report compilation
Final bscience report compilationFinal bscience report compilation
Final bscience report compilation
 
Final bscience report compilation
Final bscience report compilationFinal bscience report compilation
Final bscience report compilation
 
Finaleeee bscience 2
Finaleeee bscience 2Finaleeee bscience 2
Finaleeee bscience 2
 
Building Science 2
Building Science 2Building Science 2
Building Science 2
 
B.science report 1.2
B.science report 1.2B.science report 1.2
B.science report 1.2
 
Building Science Project 1 : Lighting & Acoustic Performance Evaluation & Design
Building Science Project 1 : Lighting & Acoustic Performance Evaluation & DesignBuilding Science Project 1 : Lighting & Acoustic Performance Evaluation & Design
Building Science Project 1 : Lighting & Acoustic Performance Evaluation & Design
 
Final bsc
Final bscFinal bsc
Final bsc
 
Building Science II: Lighting Report
Building Science II: Lighting ReportBuilding Science II: Lighting Report
Building Science II: Lighting Report
 
Final l
Final lFinal l
Final l
 
Architectural conservation arc3413 king street penang
Architectural conservation arc3413 king street penangArchitectural conservation arc3413 king street penang
Architectural conservation arc3413 king street penang
 
Building Science II Report
Building Science II ReportBuilding Science II Report
Building Science II Report
 
Acoustic Analysis Project 1
Acoustic Analysis Project 1Acoustic Analysis Project 1
Acoustic Analysis Project 1
 
ACOUSTIC
ACOUSTICACOUSTIC
ACOUSTIC
 
Auditorium: A Case Study on Acoustic Design Report
Auditorium: A Case Study on Acoustic Design ReportAuditorium: A Case Study on Acoustic Design Report
Auditorium: A Case Study on Acoustic Design Report
 
bstructureproject2-150706142716-lva1-app6892.pdf
bstructureproject2-150706142716-lva1-app6892.pdfbstructureproject2-150706142716-lva1-app6892.pdf
bstructureproject2-150706142716-lva1-app6892.pdf
 
Building Structures Report
Building Structures ReportBuilding Structures Report
Building Structures Report
 

More from Ken Wong

Project 2: DOCUMENTATION OF A MEDIUM-SIZED PROJECT
Project 2: DOCUMENTATION OF A MEDIUM-SIZED PROJECTProject 2: DOCUMENTATION OF A MEDIUM-SIZED PROJECT
Project 2: DOCUMENTATION OF A MEDIUM-SIZED PROJECTKen Wong
 
Project 2 btech
Project 2 btechProject 2 btech
Project 2 btechKen Wong
 
6th avenue NYC vs Petaling street KL
6th avenue NYC vs Petaling street KL6th avenue NYC vs Petaling street KL
6th avenue NYC vs Petaling street KLKen Wong
 
bscience integration A4 report
bscience integration A4 reportbscience integration A4 report
bscience integration A4 reportKen Wong
 
Dead load of structure
Dead load of structureDead load of structure
Dead load of structureKen Wong
 
Fettucine Truss Bridge report
Fettucine Truss Bridge reportFettucine Truss Bridge report
Fettucine Truss Bridge reportKen Wong
 
In adaptation report
In adaptation reportIn adaptation report
In adaptation reportKen Wong
 
ACTIC case study
ACTIC case studyACTIC case study
ACTIC case studyKen Wong
 
ACTIC presentation
ACTIC presentationACTIC presentation
ACTIC presentationKen Wong
 
Measured drawings report
Measured drawings reportMeasured drawings report
Measured drawings reportKen Wong
 
Project 3 WIP
Project 3 WIPProject 3 WIP
Project 3 WIPKen Wong
 
Interior Renderings WIP
Interior Renderings WIPInterior Renderings WIP
Interior Renderings WIPKen Wong
 
Exterior renderings WIP
Exterior renderings WIPExterior renderings WIP
Exterior renderings WIPKen Wong
 
Project 1 WIP
Project 1 WIPProject 1 WIP
Project 1 WIPKen Wong
 
Bcon revised
Bcon revisedBcon revised
Bcon revisedKen Wong
 
Walter gropius and frank lloyd wright
Walter gropius and frank lloyd wrightWalter gropius and frank lloyd wright
Walter gropius and frank lloyd wrightKen Wong
 
Port dickson site analysis
Port dickson site analysisPort dickson site analysis
Port dickson site analysisKen Wong
 

More from Ken Wong (20)

Project 2: DOCUMENTATION OF A MEDIUM-SIZED PROJECT
Project 2: DOCUMENTATION OF A MEDIUM-SIZED PROJECTProject 2: DOCUMENTATION OF A MEDIUM-SIZED PROJECT
Project 2: DOCUMENTATION OF A MEDIUM-SIZED PROJECT
 
Project 2 btech
Project 2 btechProject 2 btech
Project 2 btech
 
Syp+comp
Syp+compSyp+comp
Syp+comp
 
6th avenue NYC vs Petaling street KL
6th avenue NYC vs Petaling street KL6th avenue NYC vs Petaling street KL
6th avenue NYC vs Petaling street KL
 
bscience integration A4 report
bscience integration A4 reportbscience integration A4 report
bscience integration A4 report
 
Dead load of structure
Dead load of structureDead load of structure
Dead load of structure
 
Fettucine Truss Bridge report
Fettucine Truss Bridge reportFettucine Truss Bridge report
Fettucine Truss Bridge report
 
In adaptation report
In adaptation reportIn adaptation report
In adaptation report
 
ACTIC case study
ACTIC case studyACTIC case study
ACTIC case study
 
ACTIC presentation
ACTIC presentationACTIC presentation
ACTIC presentation
 
Drawings
Drawings Drawings
Drawings
 
Measured drawings report
Measured drawings reportMeasured drawings report
Measured drawings report
 
Photobook
PhotobookPhotobook
Photobook
 
Project 3 WIP
Project 3 WIPProject 3 WIP
Project 3 WIP
 
Interior Renderings WIP
Interior Renderings WIPInterior Renderings WIP
Interior Renderings WIP
 
Exterior renderings WIP
Exterior renderings WIPExterior renderings WIP
Exterior renderings WIP
 
Project 1 WIP
Project 1 WIPProject 1 WIP
Project 1 WIP
 
Bcon revised
Bcon revisedBcon revised
Bcon revised
 
Walter gropius and frank lloyd wright
Walter gropius and frank lloyd wrightWalter gropius and frank lloyd wright
Walter gropius and frank lloyd wright
 
Port dickson site analysis
Port dickson site analysisPort dickson site analysis
Port dickson site analysis
 

Recently uploaded

Lucknow 💋 Virgin Call Girls Lucknow | Book 8923113531 Extreme Naughty Call Gi...
Lucknow 💋 Virgin Call Girls Lucknow | Book 8923113531 Extreme Naughty Call Gi...Lucknow 💋 Virgin Call Girls Lucknow | Book 8923113531 Extreme Naughty Call Gi...
Lucknow 💋 Virgin Call Girls Lucknow | Book 8923113531 Extreme Naughty Call Gi...anilsa9823
 
Downtown Call Girls O5O91O128O Pakistani Call Girls in Downtown
Downtown Call Girls O5O91O128O Pakistani Call Girls in DowntownDowntown Call Girls O5O91O128O Pakistani Call Girls in Downtown
Downtown Call Girls O5O91O128O Pakistani Call Girls in Downtowndajasot375
 
FULL ENJOY - 9953040155 Call Girls in Noida | Delhi
FULL ENJOY - 9953040155 Call Girls in Noida | DelhiFULL ENJOY - 9953040155 Call Girls in Noida | Delhi
FULL ENJOY - 9953040155 Call Girls in Noida | DelhiMalviyaNagarCallGirl
 
Call Girl Service in Karachi +923081633338 Karachi Call Girls
Call Girl Service in Karachi +923081633338 Karachi Call GirlsCall Girl Service in Karachi +923081633338 Karachi Call Girls
Call Girl Service in Karachi +923081633338 Karachi Call GirlsAyesha Khan
 
The First Date by Daniel Johnson (Inspired By True Events)
The First Date by Daniel Johnson (Inspired By True Events)The First Date by Daniel Johnson (Inspired By True Events)
The First Date by Daniel Johnson (Inspired By True Events)thephillipta
 
Bridge Fight Board by Daniel Johnson dtjohnsonart.com
Bridge Fight Board by Daniel Johnson dtjohnsonart.comBridge Fight Board by Daniel Johnson dtjohnsonart.com
Bridge Fight Board by Daniel Johnson dtjohnsonart.comthephillipta
 
Islamabad Escorts # 03080115551 # Escorts in Islamabad || Call Girls in Islam...
Islamabad Escorts # 03080115551 # Escorts in Islamabad || Call Girls in Islam...Islamabad Escorts # 03080115551 # Escorts in Islamabad || Call Girls in Islam...
Islamabad Escorts # 03080115551 # Escorts in Islamabad || Call Girls in Islam...wdefrd
 
FULL ENJOY - 9953040155 Call Girls in Laxmi Nagar | Delhi
FULL ENJOY - 9953040155 Call Girls in Laxmi Nagar | DelhiFULL ENJOY - 9953040155 Call Girls in Laxmi Nagar | Delhi
FULL ENJOY - 9953040155 Call Girls in Laxmi Nagar | DelhiMalviyaNagarCallGirl
 
SHIVNA SAHITYIKI APRIL JUNE 2024 Magazine
SHIVNA SAHITYIKI APRIL JUNE 2024 MagazineSHIVNA SAHITYIKI APRIL JUNE 2024 Magazine
SHIVNA SAHITYIKI APRIL JUNE 2024 MagazineShivna Prakashan
 
Olivia Cox. intertextual references.pptx
Olivia Cox. intertextual references.pptxOlivia Cox. intertextual references.pptx
Olivia Cox. intertextual references.pptxLauraFagan6
 
FULL ENJOY - 9953040155 Call Girls in Old Rajendra Nagar | Delhi
FULL ENJOY - 9953040155 Call Girls in Old Rajendra Nagar | DelhiFULL ENJOY - 9953040155 Call Girls in Old Rajendra Nagar | Delhi
FULL ENJOY - 9953040155 Call Girls in Old Rajendra Nagar | DelhiMalviyaNagarCallGirl
 
Delhi Room Call Girls : ☎ 8527673949, Low rate Call girl service
Delhi Room Call Girls : ☎ 8527673949, Low rate Call girl serviceDelhi Room Call Girls : ☎ 8527673949, Low rate Call girl service
Delhi Room Call Girls : ☎ 8527673949, Low rate Call girl serviceashishs7044
 
FULL ENJOY - 9953040155 Call Girls in Moti Nagar | Delhi
FULL ENJOY - 9953040155 Call Girls in Moti Nagar | DelhiFULL ENJOY - 9953040155 Call Girls in Moti Nagar | Delhi
FULL ENJOY - 9953040155 Call Girls in Moti Nagar | DelhiMalviyaNagarCallGirl
 
Patrakarpuram ) Cheap Call Girls In Lucknow (Adult Only) 🧈 8923113531 𓀓 Esco...
Patrakarpuram ) Cheap Call Girls In Lucknow  (Adult Only) 🧈 8923113531 𓀓 Esco...Patrakarpuram ) Cheap Call Girls In Lucknow  (Adult Only) 🧈 8923113531 𓀓 Esco...
Patrakarpuram ) Cheap Call Girls In Lucknow (Adult Only) 🧈 8923113531 𓀓 Esco...akbard9823
 
Aminabad @ Book Call Girls in Lucknow - 450+ Call Girl Cash Payment 🍵 8923113...
Aminabad @ Book Call Girls in Lucknow - 450+ Call Girl Cash Payment 🍵 8923113...Aminabad @ Book Call Girls in Lucknow - 450+ Call Girl Cash Payment 🍵 8923113...
Aminabad @ Book Call Girls in Lucknow - 450+ Call Girl Cash Payment 🍵 8923113...akbard9823
 
Roadrunner Lodge, Motel/Residence, Tucumcari NM
Roadrunner Lodge, Motel/Residence, Tucumcari NMRoadrunner Lodge, Motel/Residence, Tucumcari NM
Roadrunner Lodge, Motel/Residence, Tucumcari NMroute66connected
 
San Jon Motel, Motel/Residence, San Jon NM
San Jon Motel, Motel/Residence, San Jon NMSan Jon Motel, Motel/Residence, San Jon NM
San Jon Motel, Motel/Residence, San Jon NMroute66connected
 
Hazratganj / Call Girl in Lucknow - Phone 🫗 8923113531 ☛ Escorts Service at 6...
Hazratganj / Call Girl in Lucknow - Phone 🫗 8923113531 ☛ Escorts Service at 6...Hazratganj / Call Girl in Lucknow - Phone 🫗 8923113531 ☛ Escorts Service at 6...
Hazratganj / Call Girl in Lucknow - Phone 🫗 8923113531 ☛ Escorts Service at 6...akbard9823
 
Akola Call Girls #9907093804 Contact Number Escorts Service Akola
Akola Call Girls #9907093804 Contact Number Escorts Service AkolaAkola Call Girls #9907093804 Contact Number Escorts Service Akola
Akola Call Girls #9907093804 Contact Number Escorts Service Akolasrsj9000
 

Recently uploaded (20)

Lucknow 💋 Virgin Call Girls Lucknow | Book 8923113531 Extreme Naughty Call Gi...
Lucknow 💋 Virgin Call Girls Lucknow | Book 8923113531 Extreme Naughty Call Gi...Lucknow 💋 Virgin Call Girls Lucknow | Book 8923113531 Extreme Naughty Call Gi...
Lucknow 💋 Virgin Call Girls Lucknow | Book 8923113531 Extreme Naughty Call Gi...
 
Downtown Call Girls O5O91O128O Pakistani Call Girls in Downtown
Downtown Call Girls O5O91O128O Pakistani Call Girls in DowntownDowntown Call Girls O5O91O128O Pakistani Call Girls in Downtown
Downtown Call Girls O5O91O128O Pakistani Call Girls in Downtown
 
FULL ENJOY - 9953040155 Call Girls in Noida | Delhi
FULL ENJOY - 9953040155 Call Girls in Noida | DelhiFULL ENJOY - 9953040155 Call Girls in Noida | Delhi
FULL ENJOY - 9953040155 Call Girls in Noida | Delhi
 
Call Girl Service in Karachi +923081633338 Karachi Call Girls
Call Girl Service in Karachi +923081633338 Karachi Call GirlsCall Girl Service in Karachi +923081633338 Karachi Call Girls
Call Girl Service in Karachi +923081633338 Karachi Call Girls
 
The First Date by Daniel Johnson (Inspired By True Events)
The First Date by Daniel Johnson (Inspired By True Events)The First Date by Daniel Johnson (Inspired By True Events)
The First Date by Daniel Johnson (Inspired By True Events)
 
Bridge Fight Board by Daniel Johnson dtjohnsonart.com
Bridge Fight Board by Daniel Johnson dtjohnsonart.comBridge Fight Board by Daniel Johnson dtjohnsonart.com
Bridge Fight Board by Daniel Johnson dtjohnsonart.com
 
Islamabad Escorts # 03080115551 # Escorts in Islamabad || Call Girls in Islam...
Islamabad Escorts # 03080115551 # Escorts in Islamabad || Call Girls in Islam...Islamabad Escorts # 03080115551 # Escorts in Islamabad || Call Girls in Islam...
Islamabad Escorts # 03080115551 # Escorts in Islamabad || Call Girls in Islam...
 
Bur Dubai Call Girls # 971504361175 # Call Girls In Bur Dubai || (UAE)
Bur Dubai Call Girls # 971504361175 # Call Girls In Bur Dubai || (UAE)Bur Dubai Call Girls # 971504361175 # Call Girls In Bur Dubai || (UAE)
Bur Dubai Call Girls # 971504361175 # Call Girls In Bur Dubai || (UAE)
 
FULL ENJOY - 9953040155 Call Girls in Laxmi Nagar | Delhi
FULL ENJOY - 9953040155 Call Girls in Laxmi Nagar | DelhiFULL ENJOY - 9953040155 Call Girls in Laxmi Nagar | Delhi
FULL ENJOY - 9953040155 Call Girls in Laxmi Nagar | Delhi
 
SHIVNA SAHITYIKI APRIL JUNE 2024 Magazine
SHIVNA SAHITYIKI APRIL JUNE 2024 MagazineSHIVNA SAHITYIKI APRIL JUNE 2024 Magazine
SHIVNA SAHITYIKI APRIL JUNE 2024 Magazine
 
Olivia Cox. intertextual references.pptx
Olivia Cox. intertextual references.pptxOlivia Cox. intertextual references.pptx
Olivia Cox. intertextual references.pptx
 
FULL ENJOY - 9953040155 Call Girls in Old Rajendra Nagar | Delhi
FULL ENJOY - 9953040155 Call Girls in Old Rajendra Nagar | DelhiFULL ENJOY - 9953040155 Call Girls in Old Rajendra Nagar | Delhi
FULL ENJOY - 9953040155 Call Girls in Old Rajendra Nagar | Delhi
 
Delhi Room Call Girls : ☎ 8527673949, Low rate Call girl service
Delhi Room Call Girls : ☎ 8527673949, Low rate Call girl serviceDelhi Room Call Girls : ☎ 8527673949, Low rate Call girl service
Delhi Room Call Girls : ☎ 8527673949, Low rate Call girl service
 
FULL ENJOY - 9953040155 Call Girls in Moti Nagar | Delhi
FULL ENJOY - 9953040155 Call Girls in Moti Nagar | DelhiFULL ENJOY - 9953040155 Call Girls in Moti Nagar | Delhi
FULL ENJOY - 9953040155 Call Girls in Moti Nagar | Delhi
 
Patrakarpuram ) Cheap Call Girls In Lucknow (Adult Only) 🧈 8923113531 𓀓 Esco...
Patrakarpuram ) Cheap Call Girls In Lucknow  (Adult Only) 🧈 8923113531 𓀓 Esco...Patrakarpuram ) Cheap Call Girls In Lucknow  (Adult Only) 🧈 8923113531 𓀓 Esco...
Patrakarpuram ) Cheap Call Girls In Lucknow (Adult Only) 🧈 8923113531 𓀓 Esco...
 
Aminabad @ Book Call Girls in Lucknow - 450+ Call Girl Cash Payment 🍵 8923113...
Aminabad @ Book Call Girls in Lucknow - 450+ Call Girl Cash Payment 🍵 8923113...Aminabad @ Book Call Girls in Lucknow - 450+ Call Girl Cash Payment 🍵 8923113...
Aminabad @ Book Call Girls in Lucknow - 450+ Call Girl Cash Payment 🍵 8923113...
 
Roadrunner Lodge, Motel/Residence, Tucumcari NM
Roadrunner Lodge, Motel/Residence, Tucumcari NMRoadrunner Lodge, Motel/Residence, Tucumcari NM
Roadrunner Lodge, Motel/Residence, Tucumcari NM
 
San Jon Motel, Motel/Residence, San Jon NM
San Jon Motel, Motel/Residence, San Jon NMSan Jon Motel, Motel/Residence, San Jon NM
San Jon Motel, Motel/Residence, San Jon NM
 
Hazratganj / Call Girl in Lucknow - Phone 🫗 8923113531 ☛ Escorts Service at 6...
Hazratganj / Call Girl in Lucknow - Phone 🫗 8923113531 ☛ Escorts Service at 6...Hazratganj / Call Girl in Lucknow - Phone 🫗 8923113531 ☛ Escorts Service at 6...
Hazratganj / Call Girl in Lucknow - Phone 🫗 8923113531 ☛ Escorts Service at 6...
 
Akola Call Girls #9907093804 Contact Number Escorts Service Akola
Akola Call Girls #9907093804 Contact Number Escorts Service AkolaAkola Call Girls #9907093804 Contact Number Escorts Service Akola
Akola Call Girls #9907093804 Contact Number Escorts Service Akola
 

Building science 2 arc3413uyiyuiy 2

  • 1. 1 BUILDING SCIENCE 2 ARC3413 PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE EVALUATION AND DESIGN GREYSKYMORNING CAFE TEAM MEMBERS BRYAN LUM ZI YANG 0314959 KAN JIA WEI ADRIAN 0319384 HONG SANG WON 0314661 JOSHUA LEE YEE KAI 0315820 KEN WONG CHUN THIM 0315334 KENNETH CHANG WEI JIAN 0318252 TUTOR MR AZIM SULAIMAN
  • 2. 2 DECLARATION OF SUBMISSION This is to certify that: 1) The Report comprises our original work towards the course work on Building Science 2 (ARC3413), 2) Due acknowledgements have been made in the text to all other material used. Signed by: STUDENT NAME BRYAN LUM ZI YANG KAN JIA WEI ADRIAN HONG SANG WON JOSHUA LEE YEE KAI KEN WONG CHUN THIM KENNETH CHANG WEI JIAN
  • 3. 3 ACKNOWLEDGEMENT We would like to express our sincere thanks and gratification to our tutor, Mr Azim Sulaiman for guiding us throughout the entire working and study process and going out of his way to ensure that the group stays on the right track throughout the progress of the project. We would also like to extend our thanks to the manager and staff on duty at Greyskymorning Cafe on our multiple for their willingness to help and cooperate with the advancement of our assignment, providing invaluable information and also taking the extra step of guiding us around the building to explain and show all of the systems. Finally, we give thanks to each and every one of our very own group members whom participated flawlessly and were quick and efficient in conducting and executing their respective parts of the project with contributed to a successful completion of the project.
  • 4. 4 LIST OF FIGURES, PLATES, ILLUSTRATIONS Figure1.01 Exterior View of GreyskymorningCafé. Figure1.02 Exterior Panorama View. Figure1.03 Interior Entrance Panorama View. Figure1.04 Interior Cashier Counter Panorama View. Figure1.05 Interior Back Panorama View. Figure2.01 Lux Meter. Figure2.02 Lux Meter General SpecificationTable Figure2.03 Lux Meter Electrical SpecificationTable. Figure2.04 Sound Level Meter. Figure2.05 Sound Meter General SpecificationTable. Figure2.06 Measuring Tape. Figure2.07 DSLR Camera. Figure2.08 Bryan measuring the dimensions of building. Figure2.09 Joshua converting raw data into hard data onsite. Figure2.10 Adrian obtaining the lighting and acoustic data. Figure2.11 Sang Won Conducting Preliminary Investigations and Sketches.
  • 5. 5 Figure3.01 The External South Facing Side of Duke University School of Nursing. Figure3.02 Site Plan of the University Marked On The Map. Figure3.03 Exterior of the Café Duson in 2010. Figure3.04 Site Boundary Highlighted on A Site Plan of the Café Duson. Figure3.05 Squares Showing Lights Whilst Triangles Indicate Lights That Are Not Shown Figure3.06 Lights Being Pointed Through the Use of An Elevation Drawing. Figure3.07 Courtyard Luminaire Schedule. Figure3.08 Ground Floor Plan with Gridline of GreyskymorningCafe. Figure3.09 Zoning Spaces of GreyskymorningCafe. Figure3.10 Non-peak Lux Reading at 1.5m According to Gridline. Figure3.11 Peak Lux Reading at 1.5m According to Gridline. Figure3.12 Non-peak Lux Reading at 1.0m According to Gridline. Figure3.13 Peak Lux Reading at 1.0m According to Gridline. Figure3.14 Lux Reading at 1.5m. (Standing) Figure3.15 Lux Reading at 1.0m. (Sitting) Figure3.16 Non-peak Hour (11.30AM) Zone Dining Space. Figure3.17 Image of Zone A Dining Space. Figure3.18 Daylight (11.30AM) Calculation for Zone A. Figure3.19 Daylight (11.30AM) Factor Calculation for Zone A. Figure3.20 Daylight Factors and DistributionTable. Figure3.21 Non-Peak Hour (11.30AM) Zone Kitchen Space. Figure3.22 Panorama Image of Zone B Kitchen Space. Figure3.23 Daylight (11.30AM) Calculation for Zone B. Figure3.24 Daylight (11.30AM) Factor Calculation for Zone B.
  • 6. 6 Figure3.25 Daylight Factors and DistributionTable. Figure3.26 Non-Peak Hour (11.30AM) Zone Service Area. Figure3.27 Image of Zone C Service Area. Figure3.28 Daylight (11.30AM) Calculation for Zone C. Figure3.29 Daylight (11.30AM) Factor Calculation for Zone C. Figure3.30 Daylight Factors and DistributionTable. Figure3.31 Plan and Light Analysis Diagram obtained via Revit. Figure3.32 Plan and Light Analysis Diagram obtained via Revit. Figure3.33 Plan and Light Analysis Diagram obtained via Revit. Figure3.34 Plan and Light Analysis Diagram obtained via Revit. Figure3.35 Plan and Light Analysis Diagram obtained via Revit. Figure3.36 Plan and Light Analysis Diagram obtained via Revit. Figure3.37 Plan and Light Analysis Diagram obtained via Revit. Figure3.38 Plan and Light Analysis Diagram obtained via Revit. Figure3.39 Dining Area Facing the West Sun. Figure3.40 Kitchen Space Facing the West Sun. Figure3.41 Service Area Facing the Morning Sun. Figure3.42 Natural Skylight Illuminates The Interior Spaces. Figure3.43 Kitchen Area Illuminated with Warm Spotlights. Figure3.44Dining Spaces Illuminated with Warm Spotlights. Figure3.45Warm Mood Created by Artificial Lightings. Figure4.01 Sky City and the Auckland Skyline. Figure4.02 Site of Sky City in Auckland. Figure4.03 Hotel Layout. Figure4.04 Lightweight Drywall.
  • 7. 7 Figure4.05 Perforated Acoustic Ceiling Tiles. Figure4.06 Pre-Renovation Measured Noise Levels. Figure4.07 Commissioning Measured Noise Levels. Figure4.08 Gridlines WhichAre Used to Collect Acoustic Data. Figure4.09 Non-Peak Acoustic Reading. Figure4.10 Non-Peak Acoustic Reading. Figure4.11 Peak Acoustic Reading. Figure4.12 Peak Acoustic Reading. Figure4.13 Non-Peak Sum Intensity and Sound Intensity Levels Figure4.14 Non-Peak Sum Intensity and Sound Intensity Levels Figure4.15 Noise Criteria for Acoustic Environment in Building Interiors. Figure4.16 Sound Decibel Table. Figure4.17 Plan with Indications for SRI Calculations. Figure4.18 Plan with Indications of The Measured Outdoor Acoustic Levels.
  • 8. 8 TABLE OF CONTENTS SUBJECT PAGE Cover Page Declaration of Submission Acknowledgement List of Figures, Plates, Illustrations Table of Contents Abstract 1.0 INTRODUCTION 1.1 Aim and Objectives 1.2 Site Introduction 2.0 METHODOLOGY 2.1 Equipment and Specifications 2.1.1 Lux Meter 2.1.2 Sound Level Meter 2.1.3 Measuring Tape 2.1.4 Camera 2.2 Data Collection Method 2.2.1 Site Study 2.2.2 Procedure 3.0 LIGHTING 3.1 Precedent Studies 3.1.1 Introduction 3.1.2 Methodology
  • 9. 9 3.1.3 Analysis 3.2 Case Study 3.2.1 Site and Zoning 3.2.2 Data Tabulation and Analysis 3.2.3 Material Specification 3.2.4 Artificial Lighting Fixtures and Specifications 3.2.5 Daylight Factor Analysis 3.2.6 Artificial Light Analysis 3.2.7 Daylight and Lighting Diagrams 3.2.8 Lighting Analysis 4.0 ACOUSTICS 4.1 Precedent Studies 4.1.1 Introduction 4.1.2 Objectives and Issues 4.1.3 Existing Construction 4.1.4 Pre-Renovation Measurements 4.1.5 Design Standard 4.1.6 Final Treatment 4.1.7 Commissioning Measurements 4.1.8 Discussion and Conclusion 4.2 Case Study 4.2.1 Site and Zoning 4.2.2 Data Tabulation and Analysis 4.2.3 Material Specification 4.2.4 Fixtures and Specifications 4.2.5 Sound Reduction Index Calculation
  • 10. 10 4.2.6 Reverberation Time 4.2.7 Acoustic Analysis and Evaluation 5.0 CONCLUSION APPENDIX REFERENCES
  • 11. 11 ABSTRACT This research report aims to look into the lighting and acoustic properties of a chosen commercial building, Greyskymorning Café in SS13 Subang Jaya. The services and parts of the building include: the cashier counter, the kitchen, the seating location, the porch, and the back area connecting to the service area as well as the adjacent shoplot to the toilets. Throughout the findings and analysis of lighting and acoustics, the functions and any information of the systems will be studied extensively in conjunction with the building to further understand the importance of the system in a building’s properties operation. Findings and conclusions that are made as a result of this study will be made through our understanding of these said services. Not least forth these services will be adjudged to and by the Malaysian Standard 1525 (MS1525) and requirements as well as other relevant rules and regulations stipulated by relevant authorities and organisations.
  • 12. 12 1.0 INTRODUCTION 1.1 AIM AND OBJECTIVES The aim of the assignment is to gain a better understanding in the lighting and acoustic systems as well as their properties in a given space or building. Furthermore, from the experience gained from this study the aim would be to compile and record the data and provide critical analysis in the form of a written report. The objectives of this assignment include and procurement of a complete written report with data gained through documentation from the site visits on the building. The criteria of the analysis of the space in relation to the lighting and acoustic and how these properties work together is also to be made an objective. At the end of the assignment students should have a better understanding on lighting and acoustics, as well as all its relevant associates that come with it, including better understanding of calculations of light and acoustic (Lumen and PSALI), as well as how different materials and building layout all correspond with lighting and acoustic performance
  • 13. 13 1.2 SITE INTRODUCTION Figure 1.01 Exterior View of GreyskymorningCafé. (Wong,2016) Greyskymorning Café, the site chosen for this case study is an infill building that is sandwiched in between a church, City Harvest Church, and a restaurant, Food Industrie. The café also serves as an access point and circulation between these areas, as well as to more points of the building on the second floor, as well as a saloon that is only accessible via entering Greskymorning. All these commercial and service buildings form an entire structure formally known as EX8, with its own compound dictated by a fence as well as parking lots in and around the structure. EX8 is located in SS13 Subang Jaya where it is predominantly surrounded by factories and manufacturing plants. However, within the vicinity also lies an International School, and a football stadium. The entire building, including Greyskymorning is covered in black paint and uses glass and windows exponentially to take advantage of the large amounts of sunlight that Malaysia gets everyday. Natural lighting is used extensively as a result, and the building is cooled with a mixture of air conditioning systems and natural ventilation. The building also uses a heavy amount of steel and bricks that is left as it is to provide a more modern feel and look, a movement which is getting more and more popular in this region. Greyskymorning Café has many doors and exits with links to and around other portions of EX8, and the café was chosen as our site of our study as our initial analysis revealed that due to the heavy reliance on natural lighting and interesting use of materials the data gained would provide very different results from analysis from different parts of the day. The site is also located in a factory heavy location which we feel would provide different acoustic performance results on different parts of the day as well.
  • 14. 14 Figure 1.02 Exterior Panorama View. (Hong,2016) Figure 1.03 Interior Entrance Panorama View. (Hong,2016) Figure 1.04 Interior Cashier Counter Panorama View. (Hong,2016) Figure 1.05 Interior Back Panorama View. (Hong,2016)
  • 15. 15 2.0 METHODOLOGY 2.1 EQUIPMENT AND SPECIFICATIONS 2.1.1 LUX METER Figure 2.01 Lux Meter. (http://www.bsktech.com/lutron.html) The lux meter is a digital light meter manufactured by Lutron Electronic Enterprise Co. Ltd and functions to measure the luminous flux unit and illuminance level. This device is highly accurate, using photo diodes and multi-colour correction filter with spectrums that meet the C.I.E’s international code of standards. This lux meter is used as our source for lighting data collected on site and is sourced from the University. The specifications of the device are listed below.
  • 16. 16 GENERAL SPECIFICATION Display 13mm (0.5”) LCD Range 0 – 50 000 Lux. 3 Presets Zero Adjustment Internal Adjustment Over-Input Indication of “1” on LCD Sampling Time 0.4 Seconds Sensor Structure Photo Diode and Color Correction Filter Operating Temperature 0 – 50Celcius (32 – 122 Fahrenheit) Operating Humidity Maximum Capacity at 80% R.H. Power Supply DC 9V Battery, 006P, MN1604 (PP3) or equivalent Power Consumption Approximately DC 2 mA Dimensions Main Body: 108x73x23 mm Sensor Probe: 82x55x7 mm Weight 160g (WithBattery) Miscellaneous 1) Instruction Manual 2) Leather CarryingCase Figure 2.02 Lux Meter General SpecificationTable. ELECTRICAL SPECIFICATION (23±5) RANGE RESOLUTION ACCURACY 2 000 LUX 1 LUX ± ( 5 % + 2 d ) 20 000 LUX 10 LUX ± ( 5 % + 2 d ) 50 000 LUX 100 LUX ± ( 5 % + 2 d ) *Accuracy of sensor is tested by standard parallel tungsten lamp light of 2856K temperature. Figure 2.03 Lux Meter Electrical SpecificationTable.
  • 17. 17 2.1.2 SOUND LEVEL METER Figure 2.04 Sound Level Meter. (http://www.bsktech.com/lutron.html) The sound level meter is a digital sound meter manufactured by Lutron Electronic Enterprise Co. Ltd and functions to measure the acoustic levels and decibel levels. This device is highly accurate and picks up any minute sound if pointed at the source in the correct manner. This sound meter is used as our source for acoustic data collected on site and is sourced from the University. The specifications of the device are listed below.
  • 18. 18 GENERAL SPECIFICATION Function dB ( A & C Frequency Weighting ), Time Weighting ( Fast, Slow ), Hold, Memory ( Max. & Min. ), Peak Hold, AC Output RS232 Output. Meter Default Function Range Set to Auto Range. Frequency Weighting Set to A Weighting. Time Weighting Set to Fast. Measurement Range 30 – 130 dB Resolution 0.1 dB Range Selector Auto Range: 30 – 130 dB. Manual Range: 3 Ranges, 30 – 80 dB, 50 – 100 dB, 80 – 130 dB, 50 dB On Each Step with Over & Under Range Indicating. Frequency 31.5 – 8 000 Hz Microphone Type Electric Condenser Microphone Microphone Size 12.7 mm DIA ( 0.5 inch ) Frequency Weighting Network Characteristics of A & C * A Weighting The Characteristics Is Simulated As “Human Ear Listening” Response. If Making the Environmental Sound Level Measurement, Always Select to A Weighting. Time Weighting (Fast and Slow) Fast – t=200 ms, Slow – t=500 ms * FAST Range Is the Simulated Human Ear Response Time. * SLOW Range Is Easier to Get the Average Calibrator B & K ( Bruel & kjaer ), MULTIFUNCTION ACOUSTIC CALIBRATOR 4226 Output Signal *AC Output: AC 0.5 Vrms Corresponding to Each Range Step. Out Put Impedance - 600 ohm *RS232 Output Output Terminal Terminal 1: RS232 Computer Interface Terminal, Photo Couple Isolated. Terminal 2: AC Output Terminal Terminal Socket Size: 3.5mm dia. Phone Socket. Calibration VR Built in External Calibration VR, Easy to Calibrate on 94 dB Level by Screw Driver Figure 2.05 Sound Meter General SpecificationTable.
  • 19. 19 2.1.3 MEASURING TAPE Figure 2.06 Measuring Tape. (https://www.amazon.com/Stanley-33-716-16-Foot-4-Inch-FatMax/dp/B00009OYGJ) The measuring tape is used to measure a variety of items and specifications in and around the building and site during the study period, including measurement of the dimensions of the building, walls and stairs. It is also used to measure height, especially the height of light and acoustic sources. Finally the tape is also used to ensure the constant height that the acoustic and light reading are taken from are constant and consistent. 2.1.4 CAMERA Figure 2.07 DSLR Camera. (https://www.bhphotovideo.com/c/buy/SLR-Digital-Cameras/ci/6222/N/4288586280)
  • 20. 20 The DSLR camera is used as the primary equipment to record and capture pictures of the building, lighting and acoustic conditions, and the appliances that are deemed necessary to the study. Multiple cameras belonging to fellow members were used. In some instances cameras from mobile phones were used when DSLR cameras were not readily available. 2.2 DATA COLLETION METHOD 2.2.1 SITE STUDY Figure 2.08 Bryan measuring the dimensions of building. (Wong,2016) The site visit consisted of several trips to the site over the course of the 9 week period in which we were given to complete the assignment. This was done to compensate the insufficient time to conduct a full study and to accommodate for class scheduling as well as the fact that data from different parts of the day were needed hence several trips on different times of the day were justified. The first trips consisted of preliminary investigations, followed by measurements and data gathering in the subsequent trips to the site. The team was split into teams, namely the data team, photography team and measurement team to ensure efficient work productivity.
  • 21. 21 Figure 2.09 Joshua converting raw data into hard data onsite. (Wong,2016) The preliminary investigations as well as the photo taking were quite straight forward. Sketches were drawn, and photos of the entire building, inside and out, as well as all the lighting, acoustic and appliance components were taken. From then the measurement team sought to measure the dimensions of the site, obtaining a floor plan as a result and plotted the plan with a gridline of 1.5m spacing for the purpose of data gathering. Figure 2.10 Adrian obtaining the lighting and acoustic data. (Wong,2016)
  • 22. 22 Once the gridline has been established, the data team took on the task of obtaining the data for both the lighting and acoustics from a height of 1m and 1.5m from the floor. In addition to obtaining data indoors, the data for outdoor areas immediately surrounding the building were also gathered, albeit in less quantities. Only the ground floor of the building was used for the study and the building was categorised into different zones for further analysis. 2.2.2 PROCEDURE Figure 2.11 Sang Won Conducting Preliminary Investigations and Sketches. (Kan,2016) Below is the procedure list of the entire study process: 1. Preliminary investigation and photo survey, indication of light types and sources. 2. Measurement and production of floor plans, gridlines. 3. Data gathering for light and acoustic using proper equipment at heights of 1m and 1.5m 4. Analysis of data and production of report.
  • 23. 23 3.0 LIGHTING 3.1 PRECEDENT STUDY 3.1.1 INTRODUCTION Figure 3.01 The External South Facing Side of Duke University School of Nursing. Figure 3.02 Site Plan of the University MarkedOn The Map.
  • 24. 24 Located in Durham, North Carolina, along Trent Drive, sits Duke University School of Nursing. Established in 1931 on January 2nd, it is currently ranked as 6th among the best nursing schools in the U.S. as of 2016. However, for our particular precedent studies, we are looking more in depth into the Cafe Duson located in the courtyard which is located in the East facing side of the university. Figure 3.03 Exterior of the Café Duson in 2010. The main reason that this building and site was chosen as our focus for lighting precedents was due to the similar layout as well as similarity of the facade of the overall cafe with the floor to ceiling height glass curtain walls. This provides us a platform in which we could get a good initial understanding on the properties and materials that we would face in our study later on.
  • 25. 25 3.1.2 METHODOLODY Figure 3.04 Site Boundary Highlighted on A Site Plan of the Café Duson.
  • 26. 26 Figure 3.05 Squares Showing Lights Whilst Triangles Indicate Lights That Are Not Shown On The Plan. The research started by looking at the exterior of the courtyard and how did the lighting coming from the outside would eventually affect the lighting located inside the Cafe Duson. The boundary line was set up and the materiality of the overall courtyard was identified. Three types of surfaces were identified and their reflectance was also noted, which were the following: 1. Natural Cleft Bluestone Walkway and Courtyard at 15% reflectance 2. Duke Stone Retaining Walls at 20% reflectance
  • 27. 27 3. Gray Painted Aluminum Mullions at 25% reflectance Following that, other existing conditions of the exterior were identified and noted down as well, including glazing, specifications of the existing site lighting as well as any of the other existing lighting features as well. Figure 3.06 Lights Being Pointed Through the Use of An Elevation Drawing. Specifications and glazing values of the two identified types of glass are noted as below: 1. 1” Insulated Glass Curtain Wall System of Café DUSON with U-Value of 0.57, Transmittance of 0.55 and Shading Coefficient of 0.45 2. 1” Insulated Glass – Laminated (door glass) with U-Value of 0.57, Transmittance of 0.55 and Shading Coefficient of 0.45
  • 28. 28 The specifications for the two types of lighting fixtures noted down below: Figure 3.07 Courtyard Luminaire Schedule. 3.1.3 ANALYSIS Through the research gathered as well as observations conducted on site, the exterior does not seem to directly affect the interior as the spacing of the light as well as the strength do not seem to contribute or affect the ambient luminosity of the interior of the cafe. The surrounding landscape also provides sufficient shading that can help solve any glares issues that may occur with the massive glass curtain walls that make up the facade of the Cafe Duson.
  • 29. 29 3.2 CASE STUDY 3.2.1 SITE AND ZONING Figure 3.08 Ground Floor Plan with Gridline of GreyskymorningCafe. Figure 3.09 Zoning Spaces of GreyskymorningCafe.
  • 30. 30 3.2.2 DATA TABULATION AND ANALYSIS *The lightings were recorded and measured at 1.0m and 1.5m respectively. LIGHTING DATA UNIT: LUX (lx) HEIGHT: 1.5M (STANDING) Figure 3.10 Non-peak Lux Reading at 1.5m According to Gridline. 1.5METER (LUX) PEAK HOURS 6.00PM - 6.15PM GRID A B C D E F G H I J K 1 47 17 13 11 3 3 2 2 0.7 2 39 23 16 9 3 3 3 2 0.9 3 18 22 11 7 5 5 4 1 3 3 14 4 41 17 9 2 5 5 1 1 0.9 0.8 3 5 64 63 63 6 64 34 64 7 64 38 64 Figure 3.11 Peak Lux Reading at 1.5m According to Gridline. LEGEND A DINING RED B KITCHEN YELLOW C SERVICE BLUE 1.5METER (LUX) NON PEAK HOURS 11.30AM - 12.00PM GRID A B C D E F G H I J K 1 255 85 60 62 33 21 12 15 7 2 252 148 93 32 15 12 10 12 11 3 192 144 83 55 43 45 44 31 15 12 34 4 75 61 53 33 10 15 11 12 8 11 16 5 195 193 55 6 230 225 33 7 221 218 45
  • 31. 31 LIGHTING DATA UNIT: LUX (lx) HEIGHT: 1.0M (SITTING) Figure 3.12 Non-peak Lux Reading at 1.0m According to Gridline. 1.0METER (LUX) PEAK HOURS 6.00PM - 6.15PM GRID A B C D E F G H I J K 1 42 15 10 10 3 3 2 1 0.3 2 58 23 12 11 2 2 1 1 0.5 3 21 24 15 11 4 4 3 3 4 3 15 4 51 20 11 15 4 4 2 2 1 1 4 5 23 22 22 6 32 32 32 7 36 36 36 Figure 3.13 Peak Lux Reading at 1.0m According to Gridline. LEGEND A DINING RED B KITCHEN YELLOW C SERVICE BLUE 1.0METER (LUX) NON PEAK HOURS 11.30AM - 12.00PM GRID A B C D E F G H I J K 1 283 122 35 37 17 17 15 12 6 2 272 194 90 38 16 15 5 6 8 3 288 149 76 67 34 29 41 28 14 12 37 4 155 82 45 30 18 26 8 8 13 17 37 5 270 162 42 6 272 161 64 7 273 275 40
  • 32. 32 GRID NON PEAK HOURS 11.30AM - 12.00PM PEAK HOURS 6.00PM-6.15PM A1 255 47 A2 252 39 A3 192 18 A4 75 41 A5 195 64 A6 230 64 A7 221 64 B1 85 17 B2 148 23 B3 144 22 B4 61 17 B5 193 63 B6 225 34 B7 218 38 C1 60 13 C2 93 16 C3 83 11 C4 53 9 C5 55 63 C6 33 64 C7 45 64 D1 62 11 D2 32 9 D3 55 7 D4 33 2 E1 33 3 E2 15 3 E3 43 5 E4 10 5 F1 21 3 F2 12 3 F3 45 5 F4 15 5
  • 33. 33 GRID NON PEAK HOURS 11.30AM - 12.00PM PEAK HOURS 6.00PM-6.15PM G1 12 2 G2 10 3 G3 44 4 G4 11 1 H1 15 2 H2 12 2 H3 31 1 H4 12 1 I1 7 0.7 I2 11 0.9 I3 15 3 I4 8 0.9 J3 12 3 J4 11 0.8 K3 34 14 K4 16 3 Figure 3.14 Lux Reading at 1.5m. (Standing) LEGEND A DINING RED B KITCHEN YELLOW C SERVICE BLUE
  • 34. 34 GRID NON PEAK HOURS 11.30AM - 12.00PM PEAK HOURS 6.00PM-6.15PM A1 283 42 A2 272 58 A3 288 21 A4 155 51 A5 270 23 A6 272 32 A7 273 36 B1 122 15 B2 194 23 B3 149 24 B4 82 20 B5 162 22 B6 161 32 B7 275 36 C1 35 10 C2 90 12 C3 76 15 C4 45 11 C5 42 22 C6 64 32 C7 40 36 D1 37 10 D2 38 11 D3 67 11 D4 30 15 E1 17 3 E2 16 2 E3 34 4 E4 18 4 F1 17 3 F2 15 2 F3 29 4 F4 26 4
  • 35. 35 GRID NON PEAK HOURS 11.30AM - 12.00PM PEAK HOURS 6.00PM-6.15PM G1 15 2 G2 5 1 G3 41 3 G4 8 2 H1 12 1 H2 6 1 H3 28 3 H4 8 2 I1 6 0.3 I2 8 0.5 I3 14 4 I4 13 1 J3 12 3 J4 17 1 K3 37 15 K4 37 4 Figure 3.15 Lux Reading at 1.0m. (Sitting) LEGEND A DINING RED B KITCHEN YELLOW C SERVICE BLUE
  • 36. 36 INTERPRETATION AND ANALYSIS Observation 1 The data collected at the height of 1.5m are mostly higher than the data collected at the height of 1m from the floor. Discussion and Analysis 1 The data collected at the height of 1.5m are closer to the artificial lighting. Because the surrounding walls of the café are mostly made out of glass material, daylighting from the curtain walls also affects the interior. Also, due to the building being an infill building, the adjacent buildings may have shades that affects the reading at the 1.5m height, causing it to be lower in some cases. Observation 2 The light data collected during the non-peak hour of 11.30am is significantly higher in grid A and B, moderately high in grid C and D and lower in the vicinity of grid I. Discussion and Analysis 2 The higher lux reading data collected at Grid A and B are due to the lights coming in from the adjacent curtain walls of the entrance. Between grid A2 and A3 is the entrance door, the light coming in from the entrance door affects the data significantly till grid B2 and B3. Grid C and D being the middle part of the building has a moderately high reading due to the light coming in from the entrance door between Grid A2 and A3. The data collected in grid E4, F4, G4, H4 and I4 are relatively low as the building is an infill building. Although the walls are of a curtain wall, the lux reading is low as the adjacent space is a dimly lit restaurant. The readings in grid I1 is low as the walls are constructed of concrete material.
  • 37. 37 Observation 3 The data collected during the peak hour of 6.00pm shows a lower lux reading due to the sun setting around that time. All of Grid A can be seen showing a higher lux reading when compared to the other Grid readings. Discussion and Analysis 3 The higher lux reading collected at Grid A is due to the surrounding curtain walls and it being near the entrance door. Grid A is also adjacent facing west, which is the evening sun.
  • 38. 38 3.2.3 MATERIAL SPECIFICATION ZONE A (DINING) Component Material Colour Surface Finish Reflective Value (%) Surface Area (m²) Reflec tive Index Ceiling Metal deck Black Matte 20 68.0 1.519 Wall Brick wall Brown Matte 15 10.94 1.519 Painted Wall Black Matte 15 9.05 1.519
  • 39. 39 Curtain Glass wall Transparent Glossy 6 107.5 1.517 Floor Concrete Grey Matte 15 79.8 4.500 Door Metal Frame with glass panel Black /transparent Matte/ Glossy 20/6 2.5 1.517
  • 40. 40 Stairs Steel Black Matte 20 19.8 1.519 Frosted Glass Translucent Matte 8 19.5 1.517
  • 41. 41 Furniture Timber Chair Brown Glossy 10 0.8x24 = 19.2 1.46 Timber Stool Dark Brown Matte 12 0.7x8 = 5.6 1.328 Timber table painted Brown Matte 12 0.36 x 10 = 3.6 1.328
  • 42. 42 Leather sofa Black Matte 12 2.4 1.519 Reclaimed timber table Brown Matte 12 1.1 1.328 Reclaimed palette coffee table Brown Matte 12 0.9 1.328
  • 43. 43 ZONE B (KITCHEN) Componen t Material Colour Surface Finish Reflecti ve Value (%) Surfac e Area (m²) Reflecti ve Index Ceiling Concrete Grey Matte 15 22.5 4.500 Wall Brick wall Brown Matte 15 29.2 1.519 Floor Concrete Grey Matte 15 17.1 4.5
  • 44. 44 Window Clear Glass Transparent Glossy 6 23.7 1.517 Furniture Timber Stool Dark Brown Matte 12 0.7x4 = 2.8 1.328 Reclaimed timber table Brown Matte 12 1.1 1.328
  • 45. 45 ZONE C (SERVICE) Componen t Material Colour Surface Finish Reflecti ve Value (%) Surfac e Area (m²) Reflecti ve Index Ceiling Metal deck Black Matte 20 6.65 1.519 Wall Brick wall Brown Matte 15 1.72 1.519 Curtain Glass wall Transparent Glossy 6 31.3 1.517
  • 46. 46 Floor Concrete Grey Matte 15 8.4 4.5
  • 47. 47 3.2.4 ARTIFICIAL LIGHTING FIXTURES AND SPECIFICATIONS Product Model Dowsing& Reynolds Vintage light bulb- squirrel cage filament (oldfashioned Edison) E27 screw Ratedluminous flux 610 lm Colour renderingIndex - Power 40 watts Beam Angle - Functionand Zone Placement CeilingLamp Dimmable - Colour Temperature 2200 Kelvin
  • 48. 48 Product Model LED bulb GU10 Ratedluminous flux 400lm Colour renderingIndex 90 Power 6W Beam Angle 36 degree Functionand Zone Placement Spotlight beside entrance Dimmable Yes Colour Temperature 2700K
  • 49. 49 Product Model Osram 36W Warm White Lumilux Fluorescent Tube Ratedluminous flux 1350lm Colour renderingIndex - Power 18 Watt Beam Angle - Functionand Zone Placement Display light Dimmable Yes Colour Temperature 3000 Kelvin
  • 50. 50 Product Model OSRAMLumilux T8 Cool White Ratedluminous flux 1350lm Colour renderingIndex - Power 36 Watt Beam Angle - Functionand Zone Placement Display light Dimmable Yes Colour Temperature 4000 Kelvin
  • 51. 51 3.2.5 DAYLIGHT FACTOR ANALYSIS ZONE A (DINING) Figure 3.16 Non-peak Hour (11.30AM) Zone Dining Space. Figure 3.17 Image of Zone A Dining Space. (Lee,2016)
  • 52. 52 Daylight (11.30AM) 1.5m 157.25 1.0m 206.5 Average Flux 181.88 Figure 3.18 Daylight (11.30AM) Calculation for Zone A. Zone Type Daylight Average Lux reading Daylight Factor, DF Performance based level in based on collected on MS 1525 Malaysia E0 (Lx) data, Ex (Lx) A Dining 12000 181.88 Fair Figure 3.19 Daylight (11.30AM) Factor Calculation for Zone A. Below is the daylight factors and distribution table obtained from the MS1525: Figure 3.20 Daylight Factors and DistributionTable. Based on MS1525, Zone A which is the dining area achieved an average lighting with a daylight factor of 1.52%. With a daylight factor of 1.52% it can be considered dark, however it is also a relaxing ambience for chilling and hanging out. Although the surrounding walls are mostly curtain walls, light doesn’t really illuminate the interior spaces. This is due to the surrounding buildings being dimly lit as well, therefore not much lights are being transferred into the café dining spaces. Zone DF (%) Distribution Very bright > 6 Very large with thermal and glare problems Bright 3 - 6 Good Average 1 - 3 Fair Dark 0 - 1 Poor DF = 181.88 12000 x 100% = 1.52% DF = 𝐸𝑥 𝐸𝑜 x 100%
  • 53. 53 ZONE B (KITCHEN) Figure 3.21 Non-Peak Hour (11.30AM) Zone Kitchen Space. Figure 3.22 Panorama Image of Zone B Kitchen Space. (Hong,2016)
  • 54. 54 Daylight (11.30AM) 1.5m 123 1.0m 193.4 Average Flux 158.2 Figure 3.23 Daylight (11.30AM) Calculation for Zone B. Figure 3.24 Daylight (11.30AM) Factor Calculation for Zone B. Below is the daylight factors and distribution table obtained from the MS1525: Figure 3.25 Daylight Factors and DistributionTable. Based on MS1525, Zone B which is the kitchen space achieved an average lighting with a daylight factor of 1.31%. The Kitchen space is located in front near the entrances surrounded by curtain walls. The surrounding curtain walls help to illuminate the spaces. However, it still resulted in an average lighting distribution. This is due to the external overhang that helped to shelter the interior from the afternoon sun. The façade is filled with overhangs that sheltered the ground floor from direct sun, providing shade even for the outdoor sitting area.Thus, influencing the incoming light into the kitchen space. Zone Type Daylight Average Lux reading Daylight Factor, DF Performance based level in based on collected on MS 1525 Malaysia E0 (Lx) data, Ex (Lx) B Kitchen 12000 158.2 Fair Zone DF (%) Distribution Very bright > 6 Very large with thermal and glare problems Bright 3 - 6 Good Average 1 - 3 Fair Dark 0 - 1 Poor DF = 158.2 12000 x 100% = 1.31% DF = 𝐸𝑥 𝐸𝑜 x 100%
  • 55. 55 ZONE C (SERVICE AREA) Figure 3.26 Non-Peak Hour (11.30AM) Zone Service Area. Figure 3.27 Image of Zone C Service Area. (Wong,2016)
  • 56. 56 Figure 3.28 Daylight (11.30AM) Calculation for Zone C. Zone Type Daylight Average Lux reading Daylight Factor, DF Performance based level in based on collected on MS 1525 Malaysia E0 (Lx) data, Ex (Lx) C Service 12000 16.53 Poor Figure 3.29 Daylight (11.30AM) Factor Calculation for Zone C. Below is the daylight factors and distribution table obtained from the MS1525, Figure 3.30 Daylight Factors and DistributionTable. Based on MS1525, Zone C which is the Service Area achieved a daylight factor of 0.14%. It is considerably dark in the area with poor lighting distribution according to MS1525. Being the service area, it does not require too much lighting as hardly anyone goes there. The space is also not designed for any uses except to access outdoor where the maintenance of air conditions are done. Although surrounded by curtain walls, hardly any harsh lights penetrate the space. This is due to the surrounding tall buildings outdoor that shields the spaces from direct sunlight. Daylight (11.30AM) 1.5m 13.05 1.0m 20 Average Flux 16.53 Zone DF (%) Distribution Very bright > 6 Very large with thermal and glare problems Bright 3 - 6 Good Average 1 - 3 Fair Dark 0 - 1 Poor DF = 𝐸𝑥 𝐸𝑜 x 100% DF = 16.53 12000 x 100% = 0.14%
  • 57. 57 3.2.6 ARTIFICIAL LIGHT ANALYSIS ZONE A (DINING) Dimension of room (L X W)(m) 13.41m x 4.62m Total Floor Area, A (m²) 62m² Type of Lighting Fixture LED bulb GU10 Dowsing & Reynolds Vintage light bulb Number of Fixture, N 19 4 Lumen of Lighting Fixture, F (lm) 400 610 Height of Luminaire (m) 4.05 2.4 Height of work level (m) 0.8 0.8 Mounting height (m) 3.45 1.4 Reflection Factors Ceiling- Concrete:3 Wall- Brick wall + Black Painted Wall: 2.0 Floor- Concrete Flooring: 3 Room Index, RI (K) Utilisation Factor, UF 0.4 0.57 Maintenance Factor, MF 0.8 0.8 Illuminance Level - E (Lux) Number of lamps required– N *MS1525 Recommended Dining Illumination Level – 200 Lux RI = 13.41 x 4.62 (13.41 + 4.62) x 3.45 = 1.00 RI = 13.41 x 4.62 (13.41 + 4.62) x 1.4 = 2.45 RI = L x W (L + W) x H E = 19 (400 x 0.4 x 0.8) 62 = 39.22 E = N x F x UF x MF A N = (200 − 39.22) x 62 ( 610 x 0.57 x 0.8) = 35.83 ⋍ 36 N = E x A ( F x UF x MF) Analysis: The dining area of the café is under-lit and it requires another 32 Dowsing & Reynolds Vintage light bulb to meet the requirements of MS1525. However, the cafe is surrounded by curtain walls which allows light to brighten the interior during the day. Furthermore, the café only operates until 7pm, therefore there is no need to worry for lighting issues during the night.
  • 58. 58 ZONE B (KITCHEN) Dimension of room (L X W)(m) 4.88m x 4.89m Total Floor Area, A (m²) 24m² Type of Lighting Fixture LED bulb GU10 Number of Fixture, N 12 Lumen of Lighting Fixture, F (lm) 400 Height of Luminaire (m) 4.05 Height of work level (m) 0.8 Mounting height (m) 3.45 Reflection Factors Ceiling- Concrete : 3 Wall- Brick wall + Black Painted Wall : 2.0 Floor- Concrete Flooring : 3 Room Index, RI (K) Utilisation Factor, UF 0.4 Maintenance Factor, MF 0.8 Number of lamps required – N *MS1525 Recommended Kitchen Illumination Level – 150 Lux RI = L x W (L + W) x H RI = 4.88 x 4.89 (4.88 + 4.89) x 3.45 = 0.71 N = E x A ( F x UF x MF) N = 150 x 24 ( 400 x 0.4 x 0.8) = 28.13 ⋍ 28 Analysis: The Counter/Kitchen area of the café is clearly under-lit. It would need another 16 bulbs to meet the criteria of MS1525 Recommended Illumination level. By changing the bulbs to a higher lumen can also be an alternative solution.
  • 59. 59 ZONE C (SERVICE) Dimension of room (L X W)(m) 3.60m x1.67m Total Floor Area, A (m²) 6m² Type of Lighting Fixture Dowsing & Reynolds Vintage light bulb Number of Fixture, N 1 Lumen of Lighting Fixture, F (lm) 610 Height of Luminaire (m) 2.4 Height of work level (m) 0.8 Mounting height (m) 1.4 Reflection Factors Ceiling: Concrete : 3 Wall: Brick wall + Black Painted Wall : 2.0 Floor: Concrete Flooring : 3 Room Index, RI (K) Utilisation Factor, UF 0.57 Maintenance Factor, MF 0.8 Number of lamps required – N *MS1525 Recommended Service Platform Illumination Level - 50 Lux RI = L x W (L + W) x H RI = 3.60 x 1.67 (3.60 + 1.67) x 1.4 = 0.81 N = E x A ( F x UF x MF) N = 50 x 6 ( 610 x 0.57 x 0.8) = 1.08 ⋍ 1 Analysis: The service area of the café is sufficiently lit as its illumination level meet the MS1525 Recommended illumination level of 50 Lux with the installed artificial lightings.
  • 60. 60 3.2.7 DAYLIGHT AND LIGHTING DIAGRAMS REVIT SIMULATION, DAYLIGHT ANALYSIS FLOOR PLAN Figure 3.31 Plan and Light Analysis Diagram obtained via Revit. The calculations and data recorded reveal that Zones B and C as well as a small portion of Zone A receive the most daylight. This is due to the area being next to the glass walls. Most of Zone A is located away from the glass walls hence less intensity.
  • 61. 61 DAYLIGHT ANALYSIS ZONE A (DINING) Figure 3.32 Plan and Light Analysis Diagram obtained via Revit. Zone A is very well lit even though the intensity of the daylight reduces by quite a far amount in the middle of the zone. The glass walls surrounding the zone allow for ample daylight to enter the zone without the use of much artificial lighting needed, saving costs.
  • 62. 62 DAYLIGHT ANALYSIS ZONE B (KITCHEN) Figure 3.33 Plan and Light Analysis Diagram obtained via Revit. Zone B receives the most natural light among all the zones as it is nearest to the glass walls. Furthermore, the zone is flanked by sides that allow for daylight to pass through as well. This well-lit area means that throughout the day no artificial lighting is needed to provide better illumination.
  • 63. 63 DAYLIGHT ANALYSIS ZONE C (SERVICE) Figure 3.34 Plan and Light Analysis Diagram obtained via Revit. Zone C is situated at the rear of the building and also receives a substancial amount of natural light as it is surrounded on 3 sides by glass walls. Little to no artificial lighting is needed in this zone as well, except in the case of during evenings.
  • 64. 64 ARTIFICIAL LIGHTING ANALYSIS FLOOR PLAN Figure 3.35 Plan and Light Analysis Diagram obtained via Revit. Based on our analysis the area with the highest concentration of artificial lighting is located in Zone A, with the zone providing ready illumination being the dining area for customers.
  • 65. 65 ARTIFICIAL LIGHTING ANALYSIS ZONE A (DINING) Figure 3.36 Plan and Light Analysis Diagram obtained via Revit. Zone A is most commonly exposed to artificial lighting by the fact that it is the location of space usage by the customers and hence extra lighting is needed when possible. The lighting fixtures are located on the walls and ceilings.
  • 66. 66 ARTIFICIAL LIGHTING ANALYSIS ZONE B (KITCHEN) Figure 3.37 Plan and Light Analysis Diagram obtained via Revit. Zone B receives the least amount of artificial lighting assistance due to the fact that most of the time it isn’t needed as a result of exceptional use of natural lighting. However, ceiling lights are installed in the event that artificial lighting is needed. Most of the time, these lights are left off.
  • 67. 67 ARTIFICIAL LIGHTING ANALYSIS ZONE C (SERVICE) Figure 3.38 Plan and Light Analysis Diagram obtained via Revit. Zone C also receives little to no artificial light assistance, with only a few lights in place in the event that it is needed. Usually the natural daylight is sufficient to light the area.
  • 68. 68 3.2.8 LIGHTING ANALYSIS Figure 3.39 Dining Area Facing the West Sun. (Wong,2016) Having the front façade facing west, the evening sun lights up the interior spaces during the evening. In the picture shown above, the entrance is seen allowing light into the premise. With the curtain wall installation, lights illuminate the spaces allowing for a natural light experience. Thus, also reducing the need and reliance on artificial lighting throughout the day. Figure 3.40 Kitchen Space Facing the West Sun. (Wong,2016)
  • 69. 69 The Kitchen space are also illuminated by natural light mostly. During the evening, the west sun illuminates the interior spaces through the curtain wall. Thus, it fully optimizes the daylighting of the evening sun in the space. Figure 3.41 Service Area Facing the Morning Sun. (Wong,2016) The back of the café has a service area which leads to the outdoor space for maintenance of the air conditioner. Surrounded by curtain wall, natural light illuminates the surrounding area, thus also reducing the reliance on artificial lightings. It can be observed that the service area only requires a single light bulb to achieve sufficient daylighting. Although it is considered a poor lighting distribution, however according to MS1525, a service area is sufficiently lit to 50 Lux.
  • 70. 70 Figure 3.42 Natural Skylight Illuminates The Interior Spaces. (Wong,2016) The front part of the dining spaces is also lit by natural skylight in the café. Thus, allowing natural light from the roof top to illuminate all the way to the ground floor. With the openings, it allows for the reduction and reliance on artificial lightings in the space. Figure 3.43 Kitchen Area Illuminated with Warm Spotlights. (Hong,2016) Even with all the natural lightings and transparencies, artificial lightings are also installed to light up the interior spaces and aids the café in illuminating during the morning or evening.
  • 71. 71 Although artificial lightings can provide certain aesthetic and mood to the spaces, it also serves in a very practical manner. For instance, the kitchen area has several spotlights which helps illuminates the menu items. It also helps the baristas to prepare the drinks in dimly lit situations. The kitchen which also acts as a counter, needs to be brightly lit up to allow customers to better view the menu and so on. Surrounded in conjunction with curtain walls, the kitchen/counter area is brightlylit up by natural and artificial lightings to serve for both a practical and aestheticmanner. Figure 3.44 Dining Spaces Illuminated with Warm Spotlights. (Hong,2016) The middle area ofthe café which houses the diningspaces are also lit up byartificial lightings throughout most of the day. Although surrounded by curtain walls and having several openings nearbylike the stairs,it is still not enough to provide a fair daylightingdistribution. Though with artificial lights,it can achieve the desired daylightingresults with a warm mood as a bonus. Figure 3.45 Warm Mood Created by Artificial Lightings. (Wong,2016)
  • 72. 72 To provide a better level of illumination,the interior finishes plays a huge role. For instance, the slightly tinted glass of the curtain walls decreases the glaring issues when sunlight penetrates the interior spaces of the building. Thus, helping the user feel more comfortable gazing outside. Moreover, the natural skylight from the rooftop decreases the usage of artificial lightings to achieve the sufficient daylight illumination of the interior spaces. With the inclusion of minimal artificial lightings, the interior spaces can be illuminated to desired levels and yet still achieve the mood and aestheticthat was aimed for.Thus,creatinga warm, natural and cozy feelingto the users.
  • 73. 73 4.0 ACOUSTICS 4.1 PRECEDENT STUDY 4.1.1 INTRODUCTION Figure 4.01 Sky City and the Auckland Skyline. (http://vizts.com/901-2/) Figure 4.02 Site of Sky City in Auckland. (Google Maps)
  • 74. 74 In this precedent study, the Sky City Casino and Conference Centre in Auckland was undergoing a renovation, an existing conference room is to be converted into a bar/ nightclub. The Marshall Day Acoustics were engaged in order to design a sound insulation device to mitigate the noise transmission from the bar to the hotel suites which are located on level 4, one floor above the bar’s new location which is on level 3. Complaints were made previously from the hotel as noise can be heard from the conference room when amplified music was being played. After performing noise reduction measurements before and after the renovation, it was considered that the concrete slab between the hotel rooms and conference space was the primary medium for sound transmission and so design solutions will be focus on the medium. 4.1.2 OBJECTIVES AND ISSUES Since that the concrete slab was the cause of the noise transmission between the two floors, an acoustic ceiling is design in order to mitigate and minimize the noise transmission that affects the concrete slab. This had to be achieved with a buildable and affordable solution that could accommodate the services and architectural issues that are existing. The existing structure of the building was remaining and as such there is no leeway for structural changes. The immediate obvious solution is to achieve a high degree of transmission loss at low frequencies from the planned acoustic ceiling as any mid-high frequency components of the music would be attenuated through the structure itself and hence it was merely a low frequency problem at 63 Hz - 125 Hz. 4.1.3 EXISTING CONSTRUCTION Figure 4.03 Hotel Layout.
  • 75. 75 All of the hotel suites are located one floor above the converted conference space and they all share the same floor slab. The shared ceiling floor is 120 Hibond which gives an average concrete thickness of 90 mm. The ceilings in the conference room was a perforated acoustic ceiling and the walls on both the hotel levels and the conference room were made of lightweight drywall construction. Figure 4.04 Lightweight Drywall. Figure 4.05 Perforated Acoustic Ceiling Tiles.
  • 76. 76 4.1.4 PRE-RENOVATION MEASUREMENTS Measurements were carried out in the conference room before renovation to determine the sound insulation provided by the existing structure. Audio equipment were used to generate the high noise levels required. Independently, pink noise and a dance music sample were amplified to a reverberant level of L𝑒𝑞 95- 97 dBA in the conference room. Pink noise and dance music samples were used to measure the level of noise received in the five hotel suites on Level 4. Reverberant levels of the pink noise generated in the conference room were : ● L𝑒𝑞 105 dB @ 63 Hz ● L𝑒𝑞101 dB @ 125 Hz In suite 5, the pink noise was barely audible above the ambient noise levels. In Fact the bass beat of the dance music was barely detectable hence measurements in this room were discarded. All measurements here were slightly affected by the traffic from the surrounding neighbourhood and nearby construction noise. The table below summarizes the results obtained. Figure 4.06 Pre-Renovation Measured Noise Levels.
  • 77. 77 4.1.5 DESIGN STANDARD Sound received from dance music and live bands normally consist of a rhythmic low frequency tone. When this noise is clearly identifiable from above the ambient noise levels in a bedroom than it is likely to be a nuisance to the occupants. As such, the ambient noise levels in the hotel suites were used as a benchmark for a design criterion. It is clear that it would not be practically possible to achieve acceptable noises in all the hotel suites from the previous measurement. Hence, the objective is to mitigate as much of the noise as practically possible. 4.1.6 FINAL TREATMENT An acoustic ceiling is to be incorporated into the architectural ceiling and would be suspended 2 meters below the bottom of the slab in order to avoid the structural steelwork with the construction as follow: ● 120 mm Hibond slab; ● 2000 mm air gap accommodating structural steelwork and services; ● 3 layers of R1.8, 75 mm Pink Batts insulation ● Ceiling consisting of 1 layer 21 mm plywood and 2 layers 13 mm Gib Noiseline suspended on spring hangers 4.1.7 COMMISSIONING MEASUREMENTS Sound insulation performance of the acoustic ceiling was measured in the same way as the pre-renovation measurements once the refitting is complete. The table below summarizes the results:
  • 78. 78 Figure 4.07 CommissioningMeasured Noise Levels. A comparison with the before and after measurements gives an indication that an improved sound insulation has been achieved with the acoustic ceiling. Low frequency noise level in the hotel room has a moderate increase from the noise cause by the bar. However, there was no change to the A-weighted noise levels in the rooms. Dance music was played at high levels in the bar and a moderately low level of low frequency was detectable in the hotel suites. 4.1.8 DISCUSSION AND CONCLUSION The sound insulation performance resulting from the measurement has an improvement from the previous measurement due to the installation of the acoustic ceiling but it was not as great as predicted theoretically. This shortcoming of performance was already expected and most likely cause by the nature of the field conditions, possible material variations in the building products and also some flanking transmission through other paths. The level of noise generated by the bar need to be limited to approximately 95 dB at 63 Hz and 92 dB at 125 Hz in order to control the transmission of low frequency noise and this in turn would limit the number of complaints received. As a conclusion, the bar/night club has now been undergoing operation successfully for several months since the installation. As predicted, they were occasional complaints made by the guest staying at the hotel in rooms above which are most affectedby the bar. However, the overall result is such that the acoustic ceiling design is considered to be successful in being a sound insulation.
  • 79. 79 4.2 CASE STUDY 4.2.1 SITE AND ZONING NOISE IDENTIFICATION TYPE OF EXTERNAL SOUND SOURCE DESCRIPTION The macro site is surrounded by main roads which are heavily used by cars throughout the day (highlighted red). However, due to the location of the site noise factor from these main roads are almost unnoticeable. As for the micro site, the surrounding roads of the site is used heavily by many types of vehicles including lorries and trucks, and produce a high level of noise. However, the noise is reduced as the site is enclosed in an area, and the building surrounded by other adjacent buildings dampening outdoor noise and keeping noise pollution to a minimum. The neighboring buildings, although vary in activities do not serve any real noise intrusion to the building, as the operational hours do not coincidewith many of the activities. For instance, church activities on one side is normally conducted before or after the café operation hours and the restaurant is always constantly low on noise volume. One area in which that the café receives external noise is located at the back, where the air condition condensers are located. Fully functional during opening hours, they constantly blare out bland humming tone at up to 54dB which is most obvious at the back of the café. Towards the front the sound is eliminated from the brick wall.
  • 80. 80 SITE ZONING Figure 4.08 Gridlines WhichAre Used to Collect Acoustic Data. The gridline, established together with the lighting data collection grid, is also used to gather acoustic measurements in and around the building, with a 1.5m spacing in between each grid point, forming a total of 49 grid points.
  • 81. 81 4.2.2 DATA TABULATION AND ANALYSIS *The acoustics were recorded and measured at 1.5m. ACOUSTIC DATA UNIT: DECIBEL (dB) HEIGHT: 1.5M (STANDING) Figure 4.09 Non-Peak Acoustic Reading. Figure 4.10 Non-Peak Acoustic Reading. Non Peak Hour 11.30AM - 12.00PM GRID A B C D E F G H I J K 1 60.3 61.3 62.9 61.5 61.4 62.3 61.3 62.8 64.3 2 60.4 60.7 60.2 66.7 61.3 61.7 61.8 62.7 63.9 3 61.1 62 68.3 62 68.4 62.7 63.2 63.3 63.4 67.8 71.2 4 60.6 70.4 72 63.2 64.2 66.6 65.3 65.4 66.2 68.2 69.2 5 58 58.3 60.4 6 60 59 63.5 7 60 59.4 58.6 Non Peak Hour 11.30AM - 12.00PM GRI D A B C D E F G H I J K 1 1.07E -06 1.35E -06 1.95E -06 1.41E -06 1.38E -06 1.69E -06 1.34E -06 1.90E -06 2.69E -06 2 1.10E -06 1.17E -06 1.05E -06 4.67E -06 1.34E -06 1.47E -06 1.51E -06 1.86E -06 2.45E -06 3 1.29E -06 1.58E -06 6.76E -06 1.58E -06 6.91E -06 1.86E -06 2.08E -06 2.13E -06 2.18E -06 6.02E -06 1.31E -06 4 1.15E -06 1.10E -06 1.58E -05 2.08E -06 2.63E -06 4.57E -06 3.38E -06 3.46E -06 4.16E -06 6.60E -06 8.31E -06 5 6.30E -07 6.76E -07 1.10E -06 6 1.00E -06 7.94E -07 2.24E -06 7 1.00E -06 8.71E -07 7.24E -07
  • 82. 82 Figure 4.11 Peak Acoustic Reading. Figure 4.12 Peak Acoustic Reading. Peak Hour 5pm-5.15pm GRID A B C D E F G H I J K 1 65 63 67 69 69 68 67 67 65 2 65 64 66 71 71 67 64 66 64 3 66 68 65 66 66 65 69 66 65 69 75 4 68 70 67 71 70 68 67 68 67 74 78 5 70 71 77 6 72 73 76 7 64 65 75 Peak Hour 5pm- 5.15pm GRI D A B C D E F G H I J K 1 3.16E -06 1.99E -06 5.01E -06 7.94E -06 7.94E -06 6.30E -06 5.01E -06 5.01E -06 3.16E -06 2 3.16E -06 2.51E -06 3.98E -06 1.25E -05 1.25E -05 5.01E -06 2.51E -06 3.98E -06 2.51E -06 3 3.98E -06 6.30E -06 3.16E -06 3.98E -06 3.98E -06 3.16E -06 7.94E -06 3.98E -06 3.16E -06 7.94E -06 3.16E -05 4 6.30E -06 1.00E -05 5.01E -06 1.25E -05 1.00E -05 6.30E -06 5.01E -06 6.30E -06 5.01E -06 2.51E -05 6.30E -05 5 1.00E -05 1.25E -05 5.01E -05 6 1.58E -05 1.99E -05 3.98E -05 7 2.51E -06 3.16E -06 3.16E -05
  • 83. 83 Figure 4.13 Non-Peak Sum Intensity and Sound Intensity Levels (BELOW) Sum of Intensity for each zone, I Non Peak Hour 11.30AM - 12.00PM GRID A B C D E F G H I J K 1 2 9.62E-05 3 2.22E-05 4 5 6 9.03E-06 7 Sound Intensity level (SIL) per zone Non Peak Hour 11.30AM - 12.00PM GRID A B C D E F G H I J K 1 2 79.83 3 73.46 4 5 6 69.56 7
  • 84. 84 Figure 4.14 Peak Sum Intensity and Sound Intensity Levels (BELOW) Sum of Intensity for each zone, I Peak Hour 5pm-5.15pm GRID A B C D E F G H I J K 1 2 2.00E-04 3 1.28E-04 4 5 6 1.86E-04 7 SIL Peak Hour 5pm-5.15pm GRID A B C D E F G H I J K 1 2 83.01 3 81.07 4 5 6 82.7 7
  • 85. 85 INTERPRETATION AND ANALYSIS Observation 1 There is a peak of 70.4dB in grid B4. Discussion and Analysis 1 Grid B4 is situated near the barista counter where the making of coffee and the machinery sound are produced. Observation 2 There is a significant rise in decibels in grid k3 and k4. Discussion and Analysis 2 There is a backdoor adjacent between grid k3 and k4. Outside the perimeter are the placement of the outdoor condensers which are required to operate the air conditioner of the café and the nearby restaurant. The rise in decibels in grid k3 and k4 are due to the sound coming from the outdoor spaces. Observation 3 During the non-peak hour (11.30am), Grid B4 and C4 can be seen having a significantly higher decibel when compared to the rest. Discussion and Analysis 3 The reason it has a higher decibel reading could be due to the placement of the cake display cabinet/fridge. Another reason could be during the time of measurement, the Ice blender located in the kitchen area is being used.
  • 86. 86 Observation 4 During the peak hour (6.00pm), a rise of decibels in the collected data is observed. Discussion and Analysis 4 The data collected shows a rise in decibels during the peak hour. Working adults and university students hang out in the café after classes and work. There were more people in the café at the time, chatting, talking and discussing on things. Thus, the higher reading. Moreover, during the peak hour, music was even played in the background. No music was playing in the background during the non-peak hour visit. Observation 5 During the peak hour (6.00pm), a rise of decibels in Grid B5, B6, C5, C6 and C7 are collected and measured. Discussion and Analysis 5 The higher decibels in Grid B5, B6, C5, C6 and C7 are due to the coffee machines, grinders and etc. working to meet the demand of the customers during the peak hour of 6pm.
  • 87. 87 4.2.3 MATERIAL SPECIFICATION ZONE A (DINING) Component Material Colour Surface Finish Absorpti on Coefficie nt (500 Hz) Abso rptio n Coeff icient (200 0 Hz) Surfa ce Area (m²) Ceiling Metal deck Black Matte 0.7 0.86 68.0 Wall Brick wall Brown Matte 0.02 0.02 10.94 Painted Wall Black Matte 0.02 0.02 9.05
  • 88. 88 Curtain Glass wall Transparent Glossy 0.04 0.03 107.5 Floor Concrete Grey Matte 0.05 0.05 79.8 Door Metal Frame with glass panel Black /transparent Matte/ Glossy 0.04 0.03 2.5
  • 89. 89 Stairs Steel Black Matte 0.7 0.86 19.8 Frosted Glass Translucent Matte 0.04 0.03 19.5
  • 90. 90 Furniture Timber Chair Brown Glossy 0.22 0.38 0.8x24 = 19.2 Timber Stool Dark Brown Matte 0.22 0.38 0.7x8 = 5.6 Timber table painted Brown Matte 0.22 0.38 0.36 x 10 = 3.6
  • 91. 91 Leather sofa Black Matte 0.28 0.28 2.4 Reclaimed timber table Brown Matte 0.22 0.38 1.1 Reclaimed palette coffee table Brown Matte 0.22 0.38 0.9
  • 92. 92 ZONE B (KITCHEN) Ceiling Concrete Grey Matte 0.05 0.05 22.5 Wall Brick wall Brown Matte 0.02 0.02 29.2 Floor Concrete Grey Matte 0.05 0.05 17.1
  • 93. 93 Window Clear Glass Transparent Glossy 0.04 0.03 23.7 Furniture Timber Stool Dark Brown Matte 0.22 0.38 2.8 Reclaimed timber table Brown Matte 0.22 0.38 1.1
  • 94. 94 ZONE C (SERVICE) Ceiling Metal deck Black Matte 0.7 0.86 6.65 Wall Brick wall Brown Matte 0.02 0.02 1.72 Curtain Glass wall Transparent Glossy 0.04 0.03 31.3
  • 95. 95 Floor Concrete Grey Matte 0.05 0.05 8.4
  • 96. 96 4.2.4 FIXTURES AND SPECIFICATIONS Type of Sound Source Product Model Units and zone Placement Wattage Voltage Noise Level Acson Wall Mounted Split G series R22 Model 1 unit at Zone B 880 220 52dB York Floor Ceiling Convertible Deluxe R410A 1 unit at Zone C 1130 220 55dB JAMAJKA 1.3W 1 unit at Zone A 1300 220 52dB Xs-160yx Glass Top Deep Freezers Mini Ice Cream Display Freezer 1 unit at Zone A - 220 50dB Berjaya Counter Chiller CC2100-S 1 unit at Zone B 618 220 50dB
  • 97. 97 KDK Ceiling Fan KY14X8MC -3 units at Zone A -1 unit at Zone B 760 230 45dB Phillips Rice Cooker HD3027 1 unit at Zone B 650 220 49dB Anfim Caimano Coffee Grinder 1 unit at Zone B 450 220 80dB Sharp Countertop Microwave Oven 0.9 CU. FT. 900W 1 unit at Zone B 900 120 58dB
  • 98. 98 Keesvanderwe stern Mirage 1 unit at Zone B 3600 220 85dB APPLIANCES INTENSITY CALCULATION Source Noise Level (dB) Intensity, I Acson Wall Mounted Split G series R22 Model 52 1.5849E-07 York Floor Ceiling Convertible Deluxe R410A 55 3.1623E-07 JAMAJKA 1.3W 52 1.5849E-07 Xs-160yx Glass Top Deep Freezers Mini Ice Cream Display Freezer 50 0.0000001 Berjaya Counter Chiller CC2100-S 50 0.0000001 KDK Ceiling Fan KY14X8MC 45 3.1623E-08 Phillips Rice Cooker HD3027 49 7.9433E-08 Anfim Caimano Coffee Grinder 80 8.71E-07 Sharp Countertop Microwave Oven 0.9 CU. FT. 900W 58 0.0004 Keesvanderwestern Mirage 85 3.1623E-04
  • 99. 99 Combined Appliances at Zone A Source Quantity Intensity Total Intensity KDK Ceiling Fan KY14X8MC 3 3.1623E-08 9.4869E-08 Xs-160yx Glass Top Deep Freezers Mini Ice Cream Display Freezer 1 0.0000001 0.0000001 JAMAJKA 1.3W 1 1.5849E-07 1.5849E-07 Grand Total Intensity 3.5336E-07
  • 100. 100 Combined Appliances at Zone B Source Quantity Intensity Total Intensity Acson Wall Mounted Split G series R22 Model 1 1.5849E-07 1.5849E-07 Berjaya Counter Chiller CC2100-S 1 0.0000001 0.0000001 Phillips Rice Cooker HD3027 1 7.9433E-08 7.9433E-08 Anfim Caimano Coffee Grinder 1 8.71E-07 8.71E-07 Sharp Countertop Microwave Oven 0.9 CU. FT. 900W 1 0.0004 0.0004 Keesvanderwestern Mirage 1 3.1623E-04 3.1623E-04 Grand Total Intensity 7.1745E-04
  • 101. 101 Combined Appliances at Zone C Source Quantity Intensity Total Intensity York Floor Ceiling Convertible Deluxe R410A 1 3.1623E-07 3.1623E-07 Grand Total Intensity 3.1623E-07
  • 102. 102 APPLIANCES SIL CALCULATION Sound Intensity Level (SIL) by Zone Zone Intensity, I Sound Intensity, SIL A 3.5336E-07 55.48 B 7.1745E-04 88.56 C 3.1623E-07 55 Sound Intensity Level (SIL) of entire space Zone Intensity, I A 3.5336E-07 B 7.1745E-04 C 3.1623E-07 Entire Space 7.1813E-04 𝑆𝐼𝐿 = 10 𝐿𝑜𝑔 ( 𝐼 1𝑥10−12 ) 𝑆𝐼𝐿 = 10 𝐿𝑜𝑔 ( 7.1813𝑥10−4 1𝑥10−12 ) 𝑆𝐼𝐿 = 88.56𝑑 Hence, the total SIL of the space is 88.56 dB
  • 103. 103 ANALYSIS Figure 4.15 Noise Criteriafor Acoustic Environment in Building Interiors. Figure 4.16 Sound Decibel Table.
  • 104. 104 According to Academic Resource Centre of Illinois Institute of Technology, restaurants or cafes have a noise criteria ranging from 48-52 dB. Greyskymorning cafe has a total Sound Intensity of 88.56 dB, which almost doubles the amount of acceptable sound intensity in the build environment probably due to the machinery being used in the cafe. As a comparison, Noise that exceeds 80dB is considered as too loud for normal conversation to be held and would be a nuisance to users.
  • 105. 105 4.2.5 SOUND REDUCTION INDEX (SRI) CALCULATION CEILING Component Material Colour Surface Finish Surface Area(m2 ) SRI Transmission Coefficient, T ST Ceiling Metal deck Black Matte 74.7 50 0.00001 0.000747 Concrete Grey Matte 22.5 43 0.00005 0.001125 TotalSurface Area 97.2 TotalST 0.001872 T = 1 𝑎𝑛𝑡𝑖𝑙𝑜𝑔 ( 𝑆𝑅𝐼 10 ) Tav = 𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛 𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎 = 0.001872 97.2 = 0.00002 SRI = 10 Log10 1 𝑇𝑎𝑣 = 10 Log10 1 0.00002 = 47 dB
  • 106. 106 FLOOR Component Material Colour Surface Finish Surface Area(m2 ) SRI Transmission Coefficient, T ST Floor Concrete Black Matte 105.3 50 0.00001 0.001053 TotalSurface Area 105.3 TotalST 0.001053 T = 1 𝑎𝑛𝑡𝑖𝑙𝑜𝑔 ( 𝑆𝑅𝐼 10 ) Tav = 𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛 𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎 = 0.001053 105.3 = 0.00001 SRI = 10 Log10 1 𝑇𝑎𝑣 = 10 Log10 1 0.00001 = 50 dB
  • 107. 107 Figure 4.17 Plan with Indications for SRI Calculations.
  • 108. 108 WALL A Component Material Colour Surface Finish Surface Area (m2 ) SRI Transmission Coefficient, T ST Wall Curtain Glass Wall Transparent Glossy 19.2 37 0.0002 0.00384 Door Metal Frame w/ Glass Panel Black/ Transparent Matte/ Glossy 2.8 37 0.0002 0.00056 TotalSurface Area 22 TotalST 0.0044 T = 1 𝑎𝑛𝑡𝑖𝑙𝑜𝑔 ( 𝑆𝑅𝐼 10 ) Tav = 𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛 𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎 = 0.0044 22 = 0.0002 SRI = 10 Log10 1 𝑇𝑎𝑣 = 10 Log10 1 0.0002 = 37 dB
  • 109. 109 WALL B Component Material Colour Surface Finish Surface Area (m2 ) SRI Transmission Coefficient, T ST Wall Curtain Glass Wall Transparent Glossy 52.2 37 0.0002 0.01044 Concrete Grey Matte 3.4 43 0.00005 0.0002 Door Metal Frame w/ Glass Panel Black/ Transparent Matte/ Glossy 2.8 37 0.0002 0.00056 Column Concrete Grey Matte 4.8 43 0.00005 0.00024 TotalSurface Area 63.2 TotalST 0.01144 T = 1 𝑎𝑛𝑡𝑖𝑙𝑜𝑔 ( 𝑆𝑅𝐼 10 ) Tav = 𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛 𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎 = 0.01144 63.2 = 0.00018 SRI = 10 Log10 1 𝑇𝑎𝑣 = 10 Log10 1 0.00018 = 37 dB
  • 110. 110 WALL C Component Material Colour Surface Finish Surface Area (m2 ) SRI Transmission Coefficient, T ST Wall Brick Wall Brown Matte 11.57 45 0.00003 0.00035 Window Clear Glass Transparent Glossy 3 37 0.0002 0.0006 TotalSurface Area 14.57 TotalST 0.00095 T = 1 𝑎𝑛𝑡𝑖𝑙𝑜𝑔 ( 𝑆𝑅𝐼 10 ) Tav = 𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛 𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎 = 0.00095 14.57 = 0.00007 SRI = 10 Log10 1 𝑇𝑎𝑣 = 10 Log10 1 0.00007 = 42 dB
  • 111. 111 WALL D Component Material Colour Surface Finish Surface Area (m2 ) SRI Transmission Coefficient, T ST Wall Brick Wall Brown Matte 5.1 45 0.00003 0.00015 Window Clear Glass Transparent Glossy 10.5 37 0.0002 0.0021 TotalSurface Area 15.6 TotalST 0.00225 T = 1 𝑎𝑛𝑡𝑖𝑙𝑜𝑔 ( 𝑆𝑅𝐼 10 ) Tav = 𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛 𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎 = 0.00225 15.6 = 0.00014 SRI = 10 Log10 1 𝑇𝑎𝑣 = 10 Log10 1 0.00014 = 39 dB
  • 112. 112 WALL E Component Material Colour Surface Finish Surface Area (m2 ) SRI Transmission Coefficient, T ST Wall Brick Wall Brown Matte 1.8 45 0.00003 0.00005 Window Clear Glass Transparent Glossy 3 37 0.0002 0.0006 Door Metal Frame w/ Glass Panel Black/ Transparent Matte/ Glossy 2.8 37 0.0002 0.00056 TotalSurface Area 7.6 TotalST 0.00121 T = 1 𝑎𝑛𝑡𝑖𝑙𝑜𝑔 ( 𝑆𝑅𝐼 10 ) Tav = 𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛 𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎 = 0.00121 7.6 = 0.000159 SRI = 10 Log10 1 𝑇𝑎𝑣 = 10 Log10 1 0.000159 = 38 dB
  • 113. 113 WALL F Component Material Colour Surface Finish Surface Area (m2 ) SRI Transmission Coefficient, T ST Wall Glass Curtain Wall Transparent Glossy 43.9 37 0.0002 0.00878 Brick Wall Brown Matte 3.9 45 0.00003 0.00012 Column Concrete Grey Matte 2 43 0.00005 0.0001 TotalSurface Area 49.8 TotalST 0.009 T = 1 𝑎𝑛𝑡𝑖𝑙𝑜𝑔 ( 𝑆𝑅𝐼 10 ) Tav = 𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛 𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎 = 0.009 49.8 = 0.00018 SRI = 10 Log10 1 𝑇𝑎𝑣 = 10 Log10 1 0.00018 = 37 dB
  • 114. 114 WALL G Component Material Colour Surface Finish Surface Area(m2 ) SRI Transmission Coefficient, T ST Wall Brick Wall Brown Matte 17.9 45 0.00003 0.000537 TotalSurface Area 17.9 TotalST 0.000537 T = 1 𝑎𝑛𝑡𝑖𝑙𝑜𝑔 ( 𝑆𝑅𝐼 10 ) Tav = 𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛 𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎 = 0.000537 17.9 = 0.00003 SRI = 10 Log10 1 𝑇𝑎𝑣 = 10 Log10 1 0.00003 = 45 dB
  • 115. 115 WALL H Component Material Colour Surface Finish Surface Area (m2 ) SRI Transmission Coefficient, T ST Wall Glass Curtain Wall Transparent Glossy 7 37 0.0002 0.0014 Brick Wall Brown Matte 10.1 45 0.00003 0.0003 Door Metal Frame w/ Glass Panel Black/ Transparent Matte/ Glossy 2.8 37 0.0002 0.00056 TotalSurface Area 19.9 TotalST 0.00226 T = 1 𝑎𝑛𝑡𝑖𝑙𝑜𝑔 ( 𝑆𝑅𝐼 10 ) Tav = 𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛 𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎 = 0.00226 19.9 = 0.000114 SRI = 10 Log10 1 𝑇𝑎𝑣 = 10 Log10 1 0.000114 = 39 dB
  • 116. 116 WALL I Component Material Colour Surface Finish Surface Area(m2 ) SRI Transmission Coefficient, T ST Wall Glass Curtain Wall Transparent Glossy 15.4 37 0.0002 0.003 Brick Wall Brown Matte 2.2 45 0.00003 0.000066 TotalSurface Area 17.6 TotalST 0.003066 T = 1 𝑎𝑛𝑡𝑖𝑙𝑜𝑔 ( 𝑆𝑅𝐼 10 ) Tav = 𝑆1 𝑇1+𝑆2 𝑇2+𝑆 𝑛 𝑇𝑛 𝑇𝑜𝑡𝑎𝑙 𝑆𝑢𝑟𝑓𝑎𝑐𝑒 𝐴𝑟𝑒𝑎 = 0.003066 17.6 = 0.000174 SRI = 10 Log10 1 𝑇𝑎𝑣 = 10 Log10 1 0.000174 = 38 dB
  • 117. 117 SOUND TRANSMISSION BETWEEN INTERIOR AND EXTERIOR Due to the nature of our site, certain areas were inaccessible. Therefore, we only managed to obtain the Exterior sound levels of certain outdoor spaces. Using the formula: Exterior sound levels – SRI of the respective surface = Sound Transmission of respective surface Through this formula, we are able to obtain the Sound Transmission of the given surfaces so that we may identify its percentage in which it transmits. Figure 4.18 Plan with Indications of The Measured Outdoor Acoustic Levels.
  • 118. 118 Wall A Exterior sound levels – SRI of the respective surface = Sound Transmission of respective surface 54 dB – 37 dB = 17 dB 17𝑑𝐵 54𝑑𝐵 x 100% = 31% Wall E 73 dB – 38 dB = 35 dB 35𝑑𝐵 73𝑑𝐵 x 100% = 48% Wall F 62 dB – 37 dB = 25 dB 25𝑑𝐵 62𝑑𝐵 x 100% = 40% Average of Percentages 31+48+40 3 = 39.7% ANALYSIS Without the remaining measurements for the other surfaces, it’s quite hard to draw a proper conclusion. However, due to the similarity in the types of spaces outside as well as the materiality of the which create a very uniform Sound Reduction Index throughout the overall building, it is safe to assume that the average of the percentages would be roughly the same. Overall the buildings surface allows more than 50 percent of the exterior sound found on the site. This is most likely due to the large amounts of glass found throughout the site.
  • 120. 120 2
  • 121. 121 4.2.7 ACOUSTIC ANALYSIS AND EVALUATION The recommended Noise Criteria for a café, referring to AS/NZS 2107:2000, is in the region of 45-50dBA. The recommended reverberation time for a café should also be in the proximity of 0.4-0.6s, as stated by AS/NZS 2107:2000. However, during our testing and analysis the sound levels consistently breach the 70-80 dBA readings. To put that into perspective, the human ear works optimally at the 48-72 dBA range. Acoustic comfort in a building or space is very important for the users to feel comfortable and be able to work and play efficiently in that space. Acoustic levels also play a very important role in the balance and effect on the psychological and physiological well-being of the user. Thankfully, the building does not suffer from major acoustical disturbances from the exterior as the road networks and isolation of the site work in favour to dampen acoustic levels. The café does, however, receive some noise at the back portion in via the noise generated by the air conditioning systems. In the interiors of the café, the main acoustical noises are generated from the usage of Coffee Machines as well as Kitchen Appliances that are all important to serve customers. The café tackles these situations by placing the kitchen in a corner, away from the users and sound direction and not placing any seats or usage space within close proximity of the back portion of the café. The material usage, namely steel, bricks and wood also help in reducing the acoustical levels, with acoustic absorption characteristics that ensure acoustic acceptability of space. The café may improve its acoustic absorption characteristics further by using more soft materials which aid in absorbing sound.
  • 122. 122 5.0 CONCLUSION After conducting a detailed analysis on the site and gaining a newfound understanding on lighting and acoustic properties and functions, many conclusions may be made. Starting with the lighting design, our observations as well as calculations came to the conclusion that the building is able to receive sufficient amounts of light via natural lighting with little extra aid from artificial lights throughout all zones studied as stipulated by MS 1525. Although it may be recommended that the café adopt some shading properties in the form of shading devices as at times during our analysis we have come to find that the building, especially the areas close to the walls may receive too much light and heat, causing discomfort to the users. As for the acoustic properties, the building is exceptional in that it takes advantage of it’s infill nature to reduce acoustic disturbance from the outdoors. The relative isolation of the café and entire building itself also contributes heavily to the reduction or prevention of major acoustic hazards from penetrating anywhere close to the café. Internally the café suffers from slight acoustic hazards especially in and around the kitchen area and the back part of the café. As the noise origins are unavoidable it can be recommended that the café implement the usage of more soft materials such as pillows or carpets around the café to improve noise absorption as well as maybe even purchasing and using sound masking speakers that not only serve to absorb noise, but also play any form of music that may aid to the acoustical comfort of the customers. An example of such a product is the XOUNT 360, widely used and available in the market. Overall, this is a project that has brought us, all the members, new and improved knowledge about lighting and acoustics that are related to a building. Through this project we are also able to improve our bond from working together which will help propel us to improve ourselves as well. Finally the lessons learnt from this assignment would be crucial and important to the application and design of subsequent assignments relating to architecture that any of us may partake in the future.
  • 124. 124
  • 125. 125
  • 126. 126
  • 127. 127
  • 128. 128
  • 129. 129
  • 130. 130
  • 131. 131
  • 132. 132
  • 133. 133 REFERENCES 1) "Best Nursing Schools In The US | Collegeatlas.Org". Collegeatlas.org. N.p.,2016. Web. 6 Nov. 2016. 2) "Room Acoustic Measurements 101 - Acoustic Frontiers". Acousticfrontiers.com. N.p., 2016. Web. 7 Nov. 2016. 3) "Audio & Acoustic Measurement Instruments". Nti-audio.com. N.p., 2016. Web. 7 Nov. 2016. 4) "LUTRON ELECTRONIC ENTERPRISE CO., LTD.". Lutron.com.tw. N.p., 2016. Web. 7 Nov. 2016. 5) "Measuring Light Levels | Sustainability Workshop". Sustainabilityworkshop.autodesk.com. N.p., 2016. Web. 7 Nov. 2016. 6) "Daylight Saving Time Dates For Malaysia – Kuala Lumpur Between 2010 And 2019". Timeanddate.com. N.p., 2016. Web. 7 Nov. 2016. 7) "Definitions Of Lux, Lumens & Watts For Lighting | GREEN BUSINESS LIGHT". Greenbusinesslight.com. N.p., 2016. Web. 7 Nov. 2016. 8) "Daylight Factor | Daylighting Pattern Guide". Patternguide.advancedbuildings.net. N.p., 2016. Web. 7 Nov. 2016. 9) "Sound Absorption". Acoustical Surfaces. N.p., 2016. Web. 7 Nov. 2016. 10) "Sound Absorption Materials | Soundproof Cow". Soundproof Cow. N.p., 2016. Web. 7 Nov. 2016. 11) "Soundproofing Vs Sound Absorbing - What's The Difference? - Acoustical Surfaces". Acoustical Surfaces. N.p., 2016. Web. 7 Nov. 2016. 12) "The Daylight Factor - Designing Buildings Wiki". Designingbuildings.co.uk. N.p.,2016. Web. 7 Nov. 2016.