Purpose
The compass is an optional supplement to the ADCP to reference the ADCP readings to East-
West and North-South direction. It is to be installed externally, e.g. in a mast, away from
ferromagnetic material.
Conditions & Requirements
• The flux-gate compass shall be of such a design that it operates reliably and accurately
under the prevailing flow and environmental conditions.
• The compass shall be easy to operate and maintain.
• The compass shall be supplied with the accessories as needed for effective use.
• All external materials of the compass shall be non-corrosive.
• An operator’s manual, related to the type and model of the compass, shall be part of the
delivery.
• The electrical connections shall be of a reliable and sturdy construction.
• The compass and accessories shall be supplied in a sturdy transport case.
• The North -direction of the compass sensor shall be parallel with the longitudinal axis of the
boat.
• The installation of the sensor at the bow shall be such that the sensor can easily be
removed and re-installed with the same alignment.
• The compass shall have calibration functions. The calibration shall compensate for local
magnetic conditions and for the magnetic effects of the boat, including engine, generator
on the compass reading.
• The data shall be delivered by serial (RS232) connection either directly to the data
acquisition PC or to a ‘deck-box’ (depending on ADCP type and make).
• The compass data format shall comply with NMEA-0183 specification.
Specifications
The purchaser may execute his judicious discretion in the choice of configuration and
options.
type flux-gate compass
accuracy 0.5°
repeatability 0.2°
resolution 0.1°
tilt angle 15°
power supply 12 VDC or 24 VDC
output data format NMEA-0183 compliant
serial port RS 232
output update frequency 1 Hz
enclosure compliant to IP65
operating temperature 0 to 60°C
operating humidity 100 %
Accessories
• manual
10.023 COMPASS
As per HP-I
Approval Date: 20 May 1998 Version: 1
Equipment Specification: COMPASS Version 1 10.023-2/2
Purpose
The compass is an optional supplement to the ADCP to reference the ADCP readings to East-
West and North-South direction. It is to be installed externally, e.g. in a mast, away from
ferromagnetic material.
Conditions & Requirements
• The flux-gate compass shall be of such a design that it operates reliably and accurately
under the prevailing flow and environmental conditions.
• The compass shall be easy to operate and maintain.
• The compass shall be supplied with the accessories as needed for effective use.
• All external materials of the compass shall be non-corrosive.
• An operator’s manual, related to the type and model of the compass, shall be part of the
delivery.
• The electrical connections shall be of a reliable and sturdy construction.
• The compass and accessories shall be supplied in a sturdy transport case.
• The North -direction of the compass sensor shall be parallel with the longitudinal axis of the
boat.
• The installation of the sensor at the bow shall be such that the sensor can easily be
removed and re-installed with the same alignment.
• The compass shall have calibration functions. The calibration shall compensate for local
magnetic conditions and for the magnetic effects of the boat, including engine, generator
on the compass reading.
• The data shall be delivered by serial (RS232) connection either directly to the data
acquisition PC or to a ‘deck-box’ (depending on ADCP type and make).
• The compass data format shall comply with NMEA-0183 specification.
Specifications
The purchaser may execute his judicious discretion in the choice of configuration and
options.
type flux-gate compass
accuracy 0.5°
repeatability 0.2°
resolution 0.1°
tilt angle 15°
power supply 12 VDC or 24 VDC
output data format NMEA-0183 compliant
serial port RS 232
output update frequency 1 Hz
enclosure compliant to IP65
operating temperature 0 to 60°C
operating humidity 100 %
Accessories
• manual

More Related Content

What's hot

Related RE work (LT, 11kV & 33kV)
Related RE work (LT, 11kV & 33kV)Related RE work (LT, 11kV & 33kV)
Related RE work (LT, 11kV & 33kV)SAJAL KUMAR BAG
 
Nidec asi wind farm applications
Nidec asi wind farm applicationsNidec asi wind farm applications
Nidec asi wind farm applicationsNidec Corporation
 
Nidec asi variable frequency drives
Nidec asi variable frequency drivesNidec asi variable frequency drives
Nidec asi variable frequency drivesNidec Corporation
 
Cableway guidance note 2 draft specification
Cableway guidance note 2   draft specificationCableway guidance note 2   draft specification
Cableway guidance note 2 draft specificationhydrologyproject0
 
Utkarsh India Limited is the leading transmission line towers manufacturer in...
Utkarsh India Limited is the leading transmission line towers manufacturer in...Utkarsh India Limited is the leading transmission line towers manufacturer in...
Utkarsh India Limited is the leading transmission line towers manufacturer in...utkarshindialimited
 
Construction manual for sub stations
Construction manual for sub stationsConstruction manual for sub stations
Construction manual for sub stationsAmit Kumar
 
Nidec asi electric power solutions for pipeline applications
Nidec asi electric power solutions for pipeline applicationsNidec asi electric power solutions for pipeline applications
Nidec asi electric power solutions for pipeline applicationsNidec Corporation
 
Traction distribution
Traction distribution Traction distribution
Traction distribution Amit Kumar
 
Nidec asi service infrared termography
Nidec asi service infrared termographyNidec asi service infrared termography
Nidec asi service infrared termographyNidec Corporation
 
MV MetalClad Switchgear
MV MetalClad SwitchgearMV MetalClad Switchgear
MV MetalClad Switchgearmichaeljmack
 
Underground cabling installation
Underground cabling installationUnderground cabling installation
Underground cabling installationAmit Kumar
 
High Density Signal Conditioners From Acromag
High Density Signal Conditioners From AcromagHigh Density Signal Conditioners From Acromag
High Density Signal Conditioners From AcromagM.S. Jacobs & Associates
 
ATS, Grounding Issues & Installation Considerations
ATS, Grounding Issues & Installation ConsiderationsATS, Grounding Issues & Installation Considerations
ATS, Grounding Issues & Installation Considerationsmichaeljmack
 
Internship Report 512 -ABW
Internship Report 512 -ABWInternship Report 512 -ABW
Internship Report 512 -ABWAJEET PANDEY
 
Nidec asi electric motors & generators
Nidec asi electric motors & generatorsNidec asi electric motors & generators
Nidec asi electric motors & generatorsNidec Corporation
 

What's hot (20)

Nidec asi silcovert tn
Nidec asi silcovert tnNidec asi silcovert tn
Nidec asi silcovert tn
 
Related RE work (LT, 11kV & 33kV)
Related RE work (LT, 11kV & 33kV)Related RE work (LT, 11kV & 33kV)
Related RE work (LT, 11kV & 33kV)
 
Nidec asi wind farm applications
Nidec asi wind farm applicationsNidec asi wind farm applications
Nidec asi wind farm applications
 
Nidec asi variable frequency drives
Nidec asi variable frequency drivesNidec asi variable frequency drives
Nidec asi variable frequency drives
 
Cableway guidance note 2 draft specification
Cableway guidance note 2   draft specificationCableway guidance note 2   draft specification
Cableway guidance note 2 draft specification
 
Nidec asi silcovert gn
Nidec asi silcovert gnNidec asi silcovert gn
Nidec asi silcovert gn
 
Utkarsh India Limited is the leading transmission line towers manufacturer in...
Utkarsh India Limited is the leading transmission line towers manufacturer in...Utkarsh India Limited is the leading transmission line towers manufacturer in...
Utkarsh India Limited is the leading transmission line towers manufacturer in...
 
Design checklist instrumentation_17.01.15 (1)
Design checklist instrumentation_17.01.15 (1)Design checklist instrumentation_17.01.15 (1)
Design checklist instrumentation_17.01.15 (1)
 
Construction manual for sub stations
Construction manual for sub stationsConstruction manual for sub stations
Construction manual for sub stations
 
Nidec asi electric power solutions for pipeline applications
Nidec asi electric power solutions for pipeline applicationsNidec asi electric power solutions for pipeline applications
Nidec asi electric power solutions for pipeline applications
 
Transformers
TransformersTransformers
Transformers
 
Traction distribution
Traction distribution Traction distribution
Traction distribution
 
Nidec asi service infrared termography
Nidec asi service infrared termographyNidec asi service infrared termography
Nidec asi service infrared termography
 
MV MetalClad Switchgear
MV MetalClad SwitchgearMV MetalClad Switchgear
MV MetalClad Switchgear
 
Underground cabling installation
Underground cabling installationUnderground cabling installation
Underground cabling installation
 
vizag steel plant
vizag steel plantvizag steel plant
vizag steel plant
 
High Density Signal Conditioners From Acromag
High Density Signal Conditioners From AcromagHigh Density Signal Conditioners From Acromag
High Density Signal Conditioners From Acromag
 
ATS, Grounding Issues & Installation Considerations
ATS, Grounding Issues & Installation ConsiderationsATS, Grounding Issues & Installation Considerations
ATS, Grounding Issues & Installation Considerations
 
Internship Report 512 -ABW
Internship Report 512 -ABWInternship Report 512 -ABW
Internship Report 512 -ABW
 
Nidec asi electric motors & generators
Nidec asi electric motors & generatorsNidec asi electric motors & generators
Nidec asi electric motors & generators
 

Similar to Compass

Similar to Compass (20)

Current meter, electromagnetic
Current meter, electromagneticCurrent meter, electromagnetic
Current meter, electromagnetic
 
Acoustic doppler current profiler
Acoustic doppler current profilerAcoustic doppler current profiler
Acoustic doppler current profiler
 
Dwlr, float type with shaft encoder (sw)
Dwlr, float type with shaft encoder (sw)Dwlr, float type with shaft encoder (sw)
Dwlr, float type with shaft encoder (sw)
 
3 vt 1..5
3 vt 1..53 vt 1..5
3 vt 1..5
 
3 vt 1..5
3 vt 1..53 vt 1..5
3 vt 1..5
 
Current meter, propeller type
Current meter, propeller typeCurrent meter, propeller type
Current meter, propeller type
 
SSDACPart B Installation.pdf
SSDACPart B Installation.pdfSSDACPart B Installation.pdf
SSDACPart B Installation.pdf
 
Ct2000 es manual_english_version_1[1].0
Ct2000 es manual_english_version_1[1].0Ct2000 es manual_english_version_1[1].0
Ct2000 es manual_english_version_1[1].0
 
CNC WIRE-CUT.ppt
CNC WIRE-CUT.pptCNC WIRE-CUT.ppt
CNC WIRE-CUT.ppt
 
Current meter, pygmy type
Current meter, pygmy typeCurrent meter, pygmy type
Current meter, pygmy type
 
Encoder
EncoderEncoder
Encoder
 
Designing Solar PV Systems ( Utility Scale)
Designing Solar PV Systems ( Utility Scale)Designing Solar PV Systems ( Utility Scale)
Designing Solar PV Systems ( Utility Scale)
 
Slideshare presentation
Slideshare presentationSlideshare presentation
Slideshare presentation
 
ad590 datasheet
ad590 datasheetad590 datasheet
ad590 datasheet
 
Encoder basics
Encoder basicsEncoder basics
Encoder basics
 
Acb mitsu
Acb mitsuAcb mitsu
Acb mitsu
 
Cptg011 en (web)
Cptg011 en (web)Cptg011 en (web)
Cptg011 en (web)
 
Lect2 up380 (100329)
Lect2 up380 (100329)Lect2 up380 (100329)
Lect2 up380 (100329)
 
Micro e systems_ldk_datasheet
Micro e systems_ldk_datasheetMicro e systems_ldk_datasheet
Micro e systems_ldk_datasheet
 
SKM ArcCalc Arc Flash Hazard Calculator (NFPA 70E & IEEE 1584)
SKM ArcCalc Arc Flash Hazard Calculator (NFPA 70E & IEEE 1584)SKM ArcCalc Arc Flash Hazard Calculator (NFPA 70E & IEEE 1584)
SKM ArcCalc Arc Flash Hazard Calculator (NFPA 70E & IEEE 1584)
 

More from hydrologyproject0

More from hydrologyproject0 (20)

Specification purewater
Specification purewaterSpecification purewater
Specification purewater
 
Water purifier ion exchange resin column
Water purifier ion exchange resin columnWater purifier ion exchange resin column
Water purifier ion exchange resin column
 
Water purifier, double distillation unit
Water purifier, double distillation unitWater purifier, double distillation unit
Water purifier, double distillation unit
 
Water purifier, distillation unit (automatic)
Water purifier, distillation unit (automatic)Water purifier, distillation unit (automatic)
Water purifier, distillation unit (automatic)
 
Water geyser (heater)
Water geyser (heater)Water geyser (heater)
Water geyser (heater)
 
Water bath, general purpose
Water bath, general purposeWater bath, general purpose
Water bath, general purpose
 
Water bath, bacteriological
Water bath, bacteriologicalWater bath, bacteriological
Water bath, bacteriological
 
Wash bottle
Wash bottleWash bottle
Wash bottle
 
Volumetric flask
Volumetric flaskVolumetric flask
Volumetric flask
 
Visual accumulation tube
Visual accumulation tubeVisual accumulation tube
Visual accumulation tube
 
Vacuum pump
Vacuum pumpVacuum pump
Vacuum pump
 
Turbidity meter (nephelometer)
Turbidity meter (nephelometer)Turbidity meter (nephelometer)
Turbidity meter (nephelometer)
 
Tool kit
Tool kitTool kit
Tool kit
 
Toc analyser, microprocessor controlled
Toc analyser, microprocessor controlledToc analyser, microprocessor controlled
Toc analyser, microprocessor controlled
 
Tissue grinder
Tissue grinderTissue grinder
Tissue grinder
 
Thermometers, set of
Thermometers, set ofThermometers, set of
Thermometers, set of
 
Test tubes
Test tubesTest tubes
Test tubes
 
Test sieves with shaker
Test sieves with shakerTest sieves with shaker
Test sieves with shaker
 
Stirrer, magnetic (with hot plate)
Stirrer, magnetic (with hot plate)Stirrer, magnetic (with hot plate)
Stirrer, magnetic (with hot plate)
 
Sterliser, autoclave
Sterliser, autoclaveSterliser, autoclave
Sterliser, autoclave
 

Compass

  • 1. 10.023 COMPASS Approval Date: 20 May 1998 Reviewed on : 23 October 2007 Version: 1 Equipment Specification: COMPASS Version 1 10.023-1/2 Purpose The compass is an optional supplement to the ADCP to reference the ADCP readings to East- West and North-South direction. It is to be installed externally, e.g. in a mast, away from ferromagnetic material. Conditions & Requirements • The flux-gate compass shall be of such a design that it operates reliably and accurately under the prevailing flow and environmental conditions. • The compass shall be easy to operate and maintain. • The compass shall be supplied with the accessories as needed for effective use. • All external materials of the compass shall be non-corrosive. • An operator’s manual, related to the type and model of the compass, shall be part of the delivery. • The electrical connections shall be of a reliable and sturdy construction. • The compass and accessories shall be supplied in a sturdy transport case. • The North -direction of the compass sensor shall be parallel with the longitudinal axis of the boat. • The installation of the sensor at the bow shall be such that the sensor can easily be removed and re-installed with the same alignment. • The compass shall have calibration functions. The calibration shall compensate for local magnetic conditions and for the magnetic effects of the boat, including engine, generator on the compass reading. • The data shall be delivered by serial (RS232) connection either directly to the data acquisition PC or to a ‘deck-box’ (depending on ADCP type and make). • The compass data format shall comply with NMEA-0183 specification. Specifications The purchaser may execute his judicious discretion in the choice of configuration and options. type flux-gate compass accuracy 0.5° repeatability 0.2° resolution 0.1° tilt angle 15° power supply 12 VDC or 24 VDC output data format NMEA-0183 compliant serial port RS 232 output update frequency 1 Hz enclosure compliant to IP65 operating temperature 0 to 60°C operating humidity 100 % Accessories • manual
  • 2. 10.023 COMPASS As per HP-I Approval Date: 20 May 1998 Version: 1 Equipment Specification: COMPASS Version 1 10.023-2/2 Purpose The compass is an optional supplement to the ADCP to reference the ADCP readings to East- West and North-South direction. It is to be installed externally, e.g. in a mast, away from ferromagnetic material. Conditions & Requirements • The flux-gate compass shall be of such a design that it operates reliably and accurately under the prevailing flow and environmental conditions. • The compass shall be easy to operate and maintain. • The compass shall be supplied with the accessories as needed for effective use. • All external materials of the compass shall be non-corrosive. • An operator’s manual, related to the type and model of the compass, shall be part of the delivery. • The electrical connections shall be of a reliable and sturdy construction. • The compass and accessories shall be supplied in a sturdy transport case. • The North -direction of the compass sensor shall be parallel with the longitudinal axis of the boat. • The installation of the sensor at the bow shall be such that the sensor can easily be removed and re-installed with the same alignment. • The compass shall have calibration functions. The calibration shall compensate for local magnetic conditions and for the magnetic effects of the boat, including engine, generator on the compass reading. • The data shall be delivered by serial (RS232) connection either directly to the data acquisition PC or to a ‘deck-box’ (depending on ADCP type and make). • The compass data format shall comply with NMEA-0183 specification. Specifications The purchaser may execute his judicious discretion in the choice of configuration and options. type flux-gate compass accuracy 0.5° repeatability 0.2° resolution 0.1° tilt angle 15° power supply 12 VDC or 24 VDC output data format NMEA-0183 compliant serial port RS 232 output update frequency 1 Hz enclosure compliant to IP65 operating temperature 0 to 60°C operating humidity 100 % Accessories • manual