1. Enviro Technology Services plc
Continuous Emissions
Monitoring Systems
Proven by installations throughout the world, ET can
offer continuous emissions monitoring equipment
suitable for almost every industrial emission and
process control monitoring application.
Monitoring parameters include: SO2, NO2, NO, HCl, HF, NH3, Hg, CL2, CO, CO2,
H2O, H2S, O2, TOC (THC), O3, benzene, toluene, xylene, styrene, formaldehyde,
VOCs, contaminant gases, dust, temperature, pressure and velocity.
With almost two decades’ experience in the field, we not only supply equipment
but also can offer a comprehensive, project management, turnkey service that will
co-ordinate system design, commissioning, arrangement of utilities, back-up power
systems, signals exporting, training, service contracts and maintenance.
APPLICATIONS
• Internationally approved equipment – US EPA, TÜV, MCERTS • Waste incineration
• Multi-Gas, Multi-Path Non-Extractive Monitoring Systems • Cement
• Non-contact, cross-duct systems – High reliability, no sample system • Power plant
• Single Component Analysers (NO SO O CO CO )
x 2 2 2
• Glass
• LD 500 Laser Diode Gas Analyser (HF H O HCl NH CO CO H S O CH )
2 3 2 2 2 4
• Aluminium
• Cross-Duct Laser Particulate Monitoring Equipment • Oil and gas
• Choice of ET service contracts
www.et.co.uk
2. Continuous Emissions Monitoring Systems
Cross-Duct LD 500 Laser Diode
DOAS Systems Gas Analyser
Topping the EnviroTechnology range of CEM This latest generation tuneable diode laser system,
monitoring equipment are the ET Differential developed from 15 years’ experience of optical
Optical Absorption Spectroscopy (DOAS) systems. and DOAS cross-duct monitoring, provides an
extremely cost-effective method for single and
ET provide single (or multiple path) cross-duct,
multiple, cross-duct, stack applications.
non-contact systems, unaffected by gases, high
temperatures or particles and able to monitor a The LD 500 is the central unit in a gas
range of user-specified compounds in real time. monitoring system. Up to four laser diode heads
They also offer the speed of response necessary may be housed in the analyser – each module
for process control. measuring a different gas.
Utilising IR/UV DOAS or Laser technology, A choice of Laser Modules is available for
depending on the application, DOAS systems are different applications, e.g. H2S for sewerage
able to measure multiple gases on up to six works and oil refineries, HF for aluminium
monitoring paths offering flexibility and smelters, HCl for waste incinerators, NH3 for
performance that no other manufacturer can match. DeNOX applications, CO/CO2/H2S for process
monitoring, O2/temperature for furnace control
Specific analysers and analyser combinations are
and CH4 for petrochemical plants.
available for a wide range of applications. These
include: power plants, waste incineration,
sulphuric acid production, fertiliser production,
aluminium smelting, the cement industry and
the chemical industry.
Modular construction allows the minimum basic
system – a lightpath and a multi-gas analyser –
to be extended at a later date to meet changing Laser diode gas analyser
and more complex tasks.
• MCERTS Approved
• TÜV Approved Emitter Receiver
Power
cable
Power supply
DOAS
cross-duct
receiver
Schematic UV
showing common (NO, NO2, SO2, NH3)
configuration
Fibre optic cables
IR
(CO, CO2, HCL, HF)
Air-condition cabinet
CEMS including AR 650 and
enclosure AR 600/620 analysers
with DOAS
analysers
3. Dust, Flow and ET Compact
Other Equipment Gas Analysers
ET can provide a wide range of dust, flow and The cost-effective ET Compact
other process monitors/sensors from Europe's Analyser systems have been
leading manufacturers. specifically designed for CEM
and process control
Dust monitors include the latest MCERTS
applications. The user-friendly
approved cross-duct, in-situ and probe based
analysers are easily installed
monitors and for the measurement of flow we can
and the only requirements for
supply cross-duct ultrasonic technology as well as
start-up are compressed air
differential pressure/anubar type instruments.
and power.
Sensors and analysers for the measurement of O2,
H2O, temperature and pressure can also be supplied NOx Stack Gas Analyser
and integrated into our “turn-key” CEM systems. This well-proven chemiluminescent analyser,
integrated with a dilution, extractive probe,
provides a NOX monitoring solution, specifically
Project Management designed for use with clean gas systems and
and Turn-key process control of DENOX systems. With options
available to include the measurement of NO2, O2,
Capabilities SO2 and CO, the analyser may also be used in
many other kinds of applications.
Although it has been said many times, there is no
CEM or process control project too big or too small
for ET. With a dedicated Project Management
Team and highly experienced and knowledgeable
application specialists and engineers, ET can fully
manage any CEM project from initial consultation
to commissioning and handover. Using the latest
CAD and resource management software and
systems, ET can provide a full “turn-key” project O2000
management function including system design,
application support, site visits, liaison with third Oxygen
parties, installation, commissioning and training
services, and much more. Once given the
Analyser
go-ahead, ET can provide a professional project
A rugged, highly reliable
management and installation service that will ensure
zirconia oxide analyser
the CEM system is supplied and installed well within
featuring in-situ O2
the agreed timeframe and with the absolute
monitoring and MCERTS
minimum of client involvement and inconvenience.
approval. Suitable for
temperatures up to 500°C
with a high temperature
option (1800°C).
ET Project
Management
& Installation
Team
4. Continuous Emissions Monitoring Systems
API High Range Stack Testing
Analysers Equipment
The industrial-grade, portable,
Single Component or OEM Applications
combustion efficiency and
Model 100AH SO2 Analyser environmental analyser
A rugged yet sensitive fluorescent analyser with determines the efficiency of furnaces,
easy operator interface, high measurement boilers and other industrial combustion
ranges, high NO2 and water interference equipment helping plant operators
rejection and minimal quenching by CO2 and reduce fuel costs whilst determining
O2 needed for extractive source measurements. and monitoring pollution levels.
The versatile 0-10 to 0-5000 ppm ranges are
user-selectable from the front panel and special
multi-tasking software allows field changes as
Isokinetic Testing
well as auto ranging and dual range operation. Equipment
Model 200AH NO/NO2/NOx Analyser A wide range of manual and automatic isokinetic
Using the field-proven chemiluminescent testing equipment from the USA and Europe’s
technique for monitoring high levels of oxides of leading manufacturers.
nitrogen, the user-selectable ranges of 5-5000
ppm, in 1 ppm increments, make the Model
200AH ideal for a wide range of applications
including CEM, stack testing and process control.
Selectable measurement modes provides NO
only, NOx only or NO/NOx switching, whilst auto
ranging and remote range control allows the
analyser to be set up to exact needs.
CEMS Reference Installations
• ESB Ireland - 13 x CEM systems
• Hanson Building Products - 8 x CEM systems
• United Utilities - 2 x CEM systems
• Thames Water - 6 x CEM systems
• Knauf Insulation - 2 x CEM systems
• Quinn Glass - 1 x CEM system
• Hundreds of systems in use all over Europe
Monitoring
for Life
EnviroTechnology Services plc
Advanced Environmental Systems - Sales, Hire and Services
Kingfisher Business Park, London Road, Stroud, Gloucestershire, GL5 2BY
Tel: +44 (0)1453 733200 Fax: +44 (0)1453 733201 Email: info@et.co.uk