SlideShare a Scribd company logo
1 of 3
Version:25.09.2016
Remote Telemetry
Leachate Well
Pneumatic Pump Controller
Version:25.09.2016
 Remote monitoring and control of leachate wells
 Pneumatic or electric pumps controlled to maintain compliance levels
 Recorded parameters include:
Leachate Level, Temperature, Alarms, Battery
 Leachate level can be adjusted remotely from any internet enabled
device i.e. PC, Tablet or Smartphone
 Pump failures, High Leachate levels and other alarm situations reported
immediately via SMS and email
 Reports, charts and data viewed and downloaded via secure customised
web portal
 Complies with the Environment Agency’s Policy of ‘Continuous
Monitoring’
 Improved pneumatic pump reliability achieved by interrupting air supply
to control levels
 Stalled pumps can usually be started remotely without the need to visit
site
 24/7 operation with NO mains supply
 Choice of Solar Panel or Pneumatic Generator to recharge internal
battery
 ATEX level sensor included.
 Options include
 Leachate volume recorded by counting pump cycles or measuring flow
 Pump air pressure monitored and recorded with alarm output
Type
Customer Benefits
Ordering Information
Version:25.09.2016
Controller PC
Power
Solar SP
Pneumatic Generator PC
Pump to be controlled
Pneumatic P
Electric E
Sensor cable length
Length in metres XX
Flow measurement
Pump cycles C
Actual flow Ltrs (flow sensor) F
Example
Controller PC SP P 75 F
Controller code - PC-SP-75-F
The above example specifies a pump controller that is Solar powered, with Pneumatic Pump
Control, ATEX level sensor with 75m cable and added leachate flow logging.
For more information or site trial contact,
Landfill Solutions Ltd
18 Market Place
Bingham
Nottinghamshire. NG13 8AP
Landfill solutions Cambridge Office
Tel 01223237781
colin@landfillsolutions.co.uk

More Related Content

Similar to Datasheet-Pump Controller v0 2 (2)

Calidad de Agua - booklet
Calidad de Agua - bookletCalidad de Agua - booklet
Calidad de Agua - bookletllaccchosac
 
Lectures-CLL361.pdf
Lectures-CLL361.pdfLectures-CLL361.pdf
Lectures-CLL361.pdfssuser4355cc
 
portable_flow_measurement-pr-en PES Scotland NIVUS
portable_flow_measurement-pr-en PES Scotland NIVUSportable_flow_measurement-pr-en PES Scotland NIVUS
portable_flow_measurement-pr-en PES Scotland NIVUSDavid White
 
Converter station water-cooled pump vibration monitoring and condition assess...
Converter station water-cooled pump vibration monitoring and condition assess...Converter station water-cooled pump vibration monitoring and condition assess...
Converter station water-cooled pump vibration monitoring and condition assess...IJRES Journal
 
Pump Control Solutions_follow up.pptx
Pump Control Solutions_follow up.pptxPump Control Solutions_follow up.pptx
Pump Control Solutions_follow up.pptxSergiuGheorghe2
 
Bmssystem basic-141229052438-conversion-gate02
Bmssystem basic-141229052438-conversion-gate02Bmssystem basic-141229052438-conversion-gate02
Bmssystem basic-141229052438-conversion-gate02manjunatha appaiah
 
Measuring Compressed Air Flow
Measuring Compressed Air FlowMeasuring Compressed Air Flow
Measuring Compressed Air FlowFlow-Tech, Inc.
 
Portable flow meter for measurement of compressed air, gases, and heat quanti...
Portable flow meter for measurement of compressed air, gases, and heat quanti...Portable flow meter for measurement of compressed air, gases, and heat quanti...
Portable flow meter for measurement of compressed air, gases, and heat quanti...Classic Controls, Inc.
 
HVAC, Heating Ventilation Air Conditioning BMS
HVAC, Heating Ventilation Air Conditioning BMSHVAC, Heating Ventilation Air Conditioning BMS
HVAC, Heating Ventilation Air Conditioning BMSMohammad Azam Khan
 
Halderman ch075 lecture
Halderman ch075 lectureHalderman ch075 lecture
Halderman ch075 lecturemcfalltj
 
Irrigation controller-system3
Irrigation controller-system3Irrigation controller-system3
Irrigation controller-system3chandan kumar
 
Photovoltaic Training Course - Module 3.1 - Control and telecom systems
Photovoltaic Training Course - Module 3.1 - Control and telecom systemsPhotovoltaic Training Course - Module 3.1 - Control and telecom systems
Photovoltaic Training Course - Module 3.1 - Control and telecom systemsLeonardo ENERGY
 
Implementation of sequential design based water level monitoring and controll...
Implementation of sequential design based water level monitoring and controll...Implementation of sequential design based water level monitoring and controll...
Implementation of sequential design based water level monitoring and controll...IJECEIAES
 

Similar to Datasheet-Pump Controller v0 2 (2) (20)

Process control lab manual
Process control lab manualProcess control lab manual
Process control lab manual
 
ABC of BMS.pdf
ABC of BMS.pdfABC of BMS.pdf
ABC of BMS.pdf
 
Calidad de Agua - booklet
Calidad de Agua - bookletCalidad de Agua - booklet
Calidad de Agua - booklet
 
DAQ System For Filter.pptx
DAQ System For Filter.pptxDAQ System For Filter.pptx
DAQ System For Filter.pptx
 
Control system
Control systemControl system
Control system
 
ENERGY PRESENTION
ENERGY PRESENTION ENERGY PRESENTION
ENERGY PRESENTION
 
Lectures-CLL361.pdf
Lectures-CLL361.pdfLectures-CLL361.pdf
Lectures-CLL361.pdf
 
portable_flow_measurement-pr-en PES Scotland NIVUS
portable_flow_measurement-pr-en PES Scotland NIVUSportable_flow_measurement-pr-en PES Scotland NIVUS
portable_flow_measurement-pr-en PES Scotland NIVUS
 
Converter station water-cooled pump vibration monitoring and condition assess...
Converter station water-cooled pump vibration monitoring and condition assess...Converter station water-cooled pump vibration monitoring and condition assess...
Converter station water-cooled pump vibration monitoring and condition assess...
 
Pump Control Solutions_follow up.pptx
Pump Control Solutions_follow up.pptxPump Control Solutions_follow up.pptx
Pump Control Solutions_follow up.pptx
 
Bms system basic
Bms system  basicBms system  basic
Bms system basic
 
Bmssystem basic-141229052438-conversion-gate02
Bmssystem basic-141229052438-conversion-gate02Bmssystem basic-141229052438-conversion-gate02
Bmssystem basic-141229052438-conversion-gate02
 
Measuring Compressed Air Flow
Measuring Compressed Air FlowMeasuring Compressed Air Flow
Measuring Compressed Air Flow
 
Portable flow meter for measurement of compressed air, gases, and heat quanti...
Portable flow meter for measurement of compressed air, gases, and heat quanti...Portable flow meter for measurement of compressed air, gases, and heat quanti...
Portable flow meter for measurement of compressed air, gases, and heat quanti...
 
HVAC, Heating Ventilation Air Conditioning BMS
HVAC, Heating Ventilation Air Conditioning BMSHVAC, Heating Ventilation Air Conditioning BMS
HVAC, Heating Ventilation Air Conditioning BMS
 
Halderman ch075 lecture
Halderman ch075 lectureHalderman ch075 lecture
Halderman ch075 lecture
 
Irrigation controller-system3
Irrigation controller-system3Irrigation controller-system3
Irrigation controller-system3
 
Photovoltaic Training Course - Module 3.1 - Control and telecom systems
Photovoltaic Training Course - Module 3.1 - Control and telecom systemsPhotovoltaic Training Course - Module 3.1 - Control and telecom systems
Photovoltaic Training Course - Module 3.1 - Control and telecom systems
 
UM PROJECT
UM PROJECTUM PROJECT
UM PROJECT
 
Implementation of sequential design based water level monitoring and controll...
Implementation of sequential design based water level monitoring and controll...Implementation of sequential design based water level monitoring and controll...
Implementation of sequential design based water level monitoring and controll...
 

Datasheet-Pump Controller v0 2 (2)

  • 2. Version:25.09.2016  Remote monitoring and control of leachate wells  Pneumatic or electric pumps controlled to maintain compliance levels  Recorded parameters include: Leachate Level, Temperature, Alarms, Battery  Leachate level can be adjusted remotely from any internet enabled device i.e. PC, Tablet or Smartphone  Pump failures, High Leachate levels and other alarm situations reported immediately via SMS and email  Reports, charts and data viewed and downloaded via secure customised web portal  Complies with the Environment Agency’s Policy of ‘Continuous Monitoring’  Improved pneumatic pump reliability achieved by interrupting air supply to control levels  Stalled pumps can usually be started remotely without the need to visit site  24/7 operation with NO mains supply  Choice of Solar Panel or Pneumatic Generator to recharge internal battery  ATEX level sensor included.  Options include  Leachate volume recorded by counting pump cycles or measuring flow  Pump air pressure monitored and recorded with alarm output Type Customer Benefits Ordering Information
  • 3. Version:25.09.2016 Controller PC Power Solar SP Pneumatic Generator PC Pump to be controlled Pneumatic P Electric E Sensor cable length Length in metres XX Flow measurement Pump cycles C Actual flow Ltrs (flow sensor) F Example Controller PC SP P 75 F Controller code - PC-SP-75-F The above example specifies a pump controller that is Solar powered, with Pneumatic Pump Control, ATEX level sensor with 75m cable and added leachate flow logging. For more information or site trial contact, Landfill Solutions Ltd 18 Market Place Bingham Nottinghamshire. NG13 8AP Landfill solutions Cambridge Office Tel 01223237781 colin@landfillsolutions.co.uk