1. Sheet List
Sheet Current
Number Sheet Name Revision
P 00 Cover sheet
P 01 Location and Site plan
P 02 Ground floor Plan
P 03 Level 1-3 Plans
P 04 Levels 4-7
P 05 Level 8, Roof
P 06 Elevations
P 07 Sections
P 08 Area analysis
P 09 Perspective renderings
P 10 Perspective renderings
SUMMARY
Accommodation
PROPOSED OFFICE DEVELOPMENT
Office accommodation of approximately 15600sqm with floor plates varying from 400 to
35 WALTERS DRIVE, OSBORNE PARK
1500sqm per floor within 2 buildings of 8 and 9 storeys. Parking is provided for 310 cars and
100 bicycles plus dedicated moped/motorcycle places. A cafe is located on the ground floor
and roof terraces on the top floors.
External Finishes :
Ground floor : Bitumen and concrete to vehiclular areas with exposed aggregate and selected
stone to pedestrian pathways. Walls to be painted concrete and selected stone to feature
walls. Frameless and semi framed glazing to lobbies, street front offices and entries. Metallic
powdercoated finishes to free standing columns and canopies.
Upper floors : Full height semi framed glazing to all office areas. Vertical and horizontal
powdercoated aluminium blades set approx. 600mm clear of the wall line to allow for
maintenance access and venting of heated air away from the facade. Blades are set at
various angles for maximum sun protection. Glazing to be tinted thermal resistant.
Roof : Colorbond roofing and cladding to plant room.
Internal Finishes :
Common and Public areas : Good quality stone/granite/marble to floors of lobbies and some
feature walls. Ceramic tile to floor and walls of washrooms. Paint to walls and ceilings
generally.
Office areas: Floor, wall and ceiling finishes to tenant requirement. Bare shell approach with
background services to prevent waste due to tenant variations.
Services :
Aim to provide 4.5 to 5 NABERS energy rating
Air conditioning : HVAC services to be high efficiency variable refrigerant volume (VRV)
systems with heat exchange capability.
Electrical : Sub metering to allow for monitoring and contraol of energy usage, High efficiency
fittings and dimming according to daylight conditions. Potential for photovoltaics to run some
common sevices
Hydraulics : 5 star water saving fittings, treatment and recycling of waste water, fire
services test water capture and possibly stormwater capture and storage(noted high water
table)
Lifts: To incorporate energy regeneration and monitoring of energy use.
BIM : Building information management systems to monitor and control energy usage
Development Application
Revision Schedule Proposed Office Development Cover sheet
Oldfield Knott Architects Pty Ltd No. Date Description
Lot 9,35- 37 Walters Road Project Number
Osborne Park
Date
07001
NOV 2010
The Royal Australian
567 Hay Street, Daglish, WA. 6008 Design/drawn by das P 00
Institute of Architects Phone (08)9381 6788 . Fax (08) 9381 4619 PO Box 849, Subiaco, WA 6904 for Skippers Transport and Quinco Properties P/L Checked by Scale 1:1
C:UsersachachadDesktop07001 DA options110624.rvt 8/07/2011 4:09:11 PM