1. New Summary Interlaboratory and Summary Instrument Group Reports
The new Summary Interlaboratory Groups reports and Summary Instrument Group reports allow group
coordinators to easily identify registrations exhibiting poor performance in one report.
COAGULATION Performance Summary: %Deviation Cycle: 6 Sample: 6 16/06/2014
Summary Interlaboratory Group Report Group: Randox
1
PT as an INR
%Deviation Summary Allowable %Deviation = 16.3%
Participant Name Registration Name 9 10 11 12 1 2 3 4 5 6 RM%DEV Lab. Ref.
Randox Laboratories Lab A 11.6 10.7 7.9 2.8 -0.3 -2.1 -2.3 -2.4 7.4 -8.1 2.5 12338/A
Randox Laboratories Lab A Inst 2 -7.8 -7.2 -15.3 -2.4 -8.1 -0.3 -9.2 -3.8 -1.0 6.0 -4.9 12338/J
Randox Laboratories Lab A BFT II R -4.6 -10.5 -6.1 -14.0 16.2 16.0 14.8 -5.5 12338/M
Randox Laboratories Lab A Sysmex CA500 -1.1C -0.5 2.8 4.6 7.5 -3.1 5.3 1.8 4.2 5.8 12338/O
Randox Laboratories Lab B Inst 1 5.9 -11.6 -7.5 22.0 -4.8 14.0 -10.8 -1.3 237024/E
Randox Laboratories Lab B Inst 2 -8.2 -5.9 -3.2 -3.3 -2.1 -4.2 -4.5 -3.4 5.6 4.2 -2.5 237024/F
Randox Laboratories Lab B Inst 3 -1.9 -5.4 3.0 0.8 -1.2 2.2 8.0 7.2 0.4 -7.2 0.6 237024/H
Randox Laboratories Lab B Sysmex CA 560 16.7 -5.7 -0.4 1.6 -0.3 -1.2 3.0 -0.6 -1.3 Too Few 237024/T
2
3
PT in seconds
%Deviation Summary Allowable %Deviation = 16.3%
Participant Name Registration Name 9 10 11 12 1 2 3 4 5 6 RM%DEV Lab. Ref.
Randox Laboratories Lab A 5.5 2.3 3.3 0.3 -0.3 -2.9 -1.6 -2.4 7.6 -5.1 0.7 12338/A
Randox Laboratories Lab A Inst 2 4.4 -2.5 -5.4 2.4 -5.0 5.1 -4.2 -0.7 2.1 4.5 0.1 12338/J
Randox Laboratories Lab A BFT II -20.9 12.6 3.2 6.5 -1.0 18.4 24.5 24.3 3.2 12338/M
Randox Laboratories Lab A Sysmex CA500 2.5 -0.8 0.3 0.9 6.0 -2.1 4.9 1.7 2.9 1.6 12338/O
Randox Laboratories Lab B Inst 1 5.6 -12.2 -7.8 22.9 -3.5 18.7 -6.9 -0.1 237024/E
Randox Laboratories Lab B Inst 2 -1.0 -2.1 2.1 -0.6 -0.3 0.0 -2.1 1.2 3.4 1.5 0.2 237024/F
Randox Laboratories Lab B Inst 3 -2.3 -5.4 3.7 -1.5 -3.1 0.0 6.6 6.7 0.9 -7.5 -0.2 237024/H
Randox Laboratories Lab B Sysmex CA 560 0.8 -5.4 1.5 0.9 2.1 -0.3 4.9 3.8 4.8 Too Few 237024/T
Group: Randox
COAGULATION Performance Summary: %Deviation Cycle: 6 Sample: 6 16/06/2014
Summary Interlaboratory Group Report
1
Report Title
States whether it is a Summary Interlaboratory Group or Summary Instrument Group Report, Group
Name, Programme and the current cycle number, sample number and return date for the current sample.
2. States the parameter, Allowable %Deviation (usually the RIQAS TDPA) and provides details such as the
participants name, registration identifier name and lab reference number. For each registration, the statistics
show %Deviation (from the Mean of Comparison) over the last ten samples and the Running Mean
%Deviation. Results highlighted in red are those that fall outside the Allowable %Deviation, making it easy
to identify if performance issues are random or long-term.
PT as an INR
%Deviation Summary Allowable %Deviation = 16.3%
Participant Name Registration Name 9 10 11 12 1 2 3 4 5 6 RM%DEV Lab. Ref.
Randox Laboratories Lab A 11.6 10.7 7.9 2.8 -0.3 -2.1 -2.3 -2.4 7.4 -8.1 2.5 12338/A
Randox Laboratories Lab A Inst 2 -7.8 -7.2 -15.3 -2.4 -8.1 -0.3 -9.2 -3.8 -1.0 6.0 -4.9 12338/J
Randox Laboratories Lab A BFT II R -4.6 -10.5 -6.1 -14.0 16.2 16.0 14.8 -5.5 12338/M
Randox Laboratories Lab A Sysmex CA500 -1.1C -0.5 2.8 4.6 7.5 -3.1 5.3 1.8 4.2 5.8 12338/O
Randox Laboratories Lab B Inst 1 5.9 -11.6 -7.5 22.0 -4.8 14.0 -10.8 -1.3 237024/E
Randox Laboratories Lab B Inst 2 -8.2 -5.9 -3.2 -3.3 -2.1 -4.2 -4.5 -3.4 5.6 4.2 -2.5 237024/F
Randox Laboratories Lab B Inst 3 -1.9 -5.4 3.0 0.8 -1.2 2.2 8.0 7.2 0.4 -7.2 0.6 237024/H
Randox Laboratories Lab B Sysmex CA 560 16.7 -5.7 -0.4 1.6 -0.3 -1.2 3.0 -0.6 -1.3 Too Few 237024/T
2
Report Table
Lab. Ref.
12338/A
12338/J
12338/M
12338/O
237024/E
237024/F
237024/H
237024/T
3
Report Chart
A line chart of the %Deviation table,
with a coloured line representing each
of the registrations, allows easy visual
identification of poor performers. The
area outside Allowable %Deviation is
denoted on the chart with a shaded
red area.
Each table and chart within the report represents up to fifteen registrations. For groups were there are
more than fifteen the registrations are divided over multiple tables and charts with a maximum of fifteen
in each.
The old format of Instrument and Interlaboratory reports are still available and participants currently
registered for group reports, will automatically receive the new report electronically. If a hard copy of
the new report is required, please contact mail@riqas.com with your Lab Reference number or Group
Name and the number of hard copies required.We would encourage participants to receive these reports
electronically as hard copies of the report are only available in black and white.
Directors: Dr S P FitzGerald CBE FREng Bsc PhD DSc (Hons) FIAE Man, R P Kelly BSc FCA.
Information correct at time of print. Randox Laboratories Limited is a subsidiary of Randox Holdings Limited a company registered within Northern Ireland with company number N.I. 614690. VAT Registered Number: GB 151 6827 08. Product availability may vary from country to country. Please contact
your local Randox representative for information. Products may be for Research Use Only and not for use in diagnostic procedures in the USA.
Randox Laboratories Limited, 55 Diamond Road, Crumlin, County Antrim, BT29 4QY, United Kingdom
+44 (0) 28 9445 4399 +44 (0) 28 9445 4398 mail@riqas.com riqas.com