Vetrivel Bangaraju has over 8 years of experience as a multi-NDT technician. He holds qualifications in UT, RT, MT, PT and has worked for various companies in Qatar, Saudi Arabia, and India performing inspections and testing on vessels, heat exchangers, pipelines, and more. His experience includes shutdown work, interpreting test results, mapping corrosion, and he is qualified to Level II standards.
1. VETRIVEL BANGARAJU
Email : vetrivelndt@gmail.com contact # :+91-9943253540
+97433554735 , +91- 8098911312
CURRICULUM VITAE
NAME :B.VETRIVEL
D.O.B :01/04/1983
DISCIPLINE :UT, RT, MT, PT
NATIONALITY :INDIAN
EXPERIENCE :8 YEARS
ACADEMIC QUALIFICATIONS:
• ITI-ELECTORNICS MECHANICS
PROFESSIONAL QUALIFICATION:
PCN LEVEL – II (UT 3.1 & 3.2)
PCN CERTIFICATE NUMBER : 322347
NDT - ASNT Level II
• UT - Ultrasonic Testing
• RT - Radiography Testing
• DPT - Dye Penetrant Testing
• MT - Magnetic Particle Testing
SEMINARS / TRAINING:
• Saudi Aramco Radiation Safety Certificate No : 1772 (RPP)
• H2S Breathing Apparatus Training attended at Venture Gulf – Qatar.
• Safety Induction – Qatar Petroleum – NGL Gas operations.
• Authorised Permit To Work Level 1 Holder (Qatar Petroleum-Gas Operations)
2. SUMMARY OF EXPERIENCE AND SKILLS:
Organization :M/s Applus Velosi Certification LLC, Qatar
CLIENT : QATAR PETROLEUM –GAS OPERATIONS(NGL)
Duration : Feb 2014 to Till Date
Designation :Multi NDT Technician
Job Details:
Ultrasonic testing, DPT & MPI carried out on vessels, Heat Exchangers and Pipelines.
Interpretation & Reporting of Ultrasonic Testing, Liquid Penetrant Testing,
Magnetic Particle Testing.
Performed corrosion & Erosion survey and mapping on, thickness survey on all
Pipelines.
Performed Longitudinal & Shear waves Scanning
Performed Hardness Testing, pipelines, equipments & weld joints.
Organization :M/s Pemco Inspection Company,Qatar
CLIENT : QATAR PETROLEUM –GAS OPERATIONS(NGL)
Duration : Jun 2013 to Dec 2013
Designation :Multi NDT Technician
Job Details:
Ultrasonic testing, DPT & MPI carried out on vessels, Heat Exchangers and Pipelines.
Interpretation & Reporting of Ultrasonic Testing, Liquid Penetrant Testing,
Magnetic Particle Testing.
Performed corrosion & Erosion survey and mapping on, thickness survey on all
Pipelines.
Performed Longitudinal & Shear waves Scanning
Performed Hardness Testing, pipelines, equipments & weld joints.
SHUTDOWN EXPIRIENCE IN GULF
Organization :M/s Applus Velosi Certification LLC, Qatar
CLIENT : QATAR PETROLEUM –GAS OPERATIONS(NGL)
Duration : Apr 2015-NGL 3 Turn Around
Designation :Multi NDT Tecnician
Organization :M/s Applus Velosi Certification LLC, Qatar
CLIENT : QATAR PETROLEUM –GAS OPERATIONS(NGL)
Duration : Mar 2014-Apr 2014-NGL 1 Turn Around
Designation :Multi NDT Tecnician
3. COMPANY : Akila Inspection Company,Qatar .
CLIENT : SHELL PEARL GTL (RASLAFAN)(Shut down)
Duration : Mar 2013-May 2013
Designation :Multi NDT Tecnician
COMPANY : NDT&CCS-SaudiArabia .
CLIENT : PETROKEMYA(Petro Chemical Plant)-KSA
Duration : Jan 2010
Designation :Multi NDT Tecnician
COMPANY : NDT&CCS-SaudiArabia .
CLIENT : AR-RAZI(METHONAL PLANT)-KSA
Duration : Jan 2011
Designation :Multi NDT Tecnician
Job Details:
Ultrasonic testing, DPT & MPI carried out on Reactors cooling oil systems lines.
Performed corrosion & Erosion survey and mapping on, thickness survey on all
Pipelines.
COMPANY : NDT & CCS – SAUDI ARABIA.
POSITION : NDT MULTI TECHNICIAN (RT, UT, MT, PT)
DURATION : FEB 2009 –JAN 2013
CLIENT : SAUDI ARAMCO,
: Khursaniyah Gas Plant, K.S.A. (under CCC)
: Manifa Gas Facilities at Khursaniyah Gas Plant, K.S.A. (GSA)
: KGF Gas plant Khursaniyah, K.S.A .HYNDAI
: Saudi Aramco Total Oil Refining and Petro Chemical
Project, K.S.A. (under DAELIM, TECHNIP)Jubail & Dammam in
Various projects on call basis
: Petrochemya (petrochemical plant in jubail K.S.A)(Shut down)
4. : Sedgam gas plant in Hafuf KSA
: SWCC Water plant in jubail KSA
Job Details:
Performed, Radiography testing Tubes ,Pipes&Pipe Lines
Performed UT Thickness Gauge on Steam lines, jacketed lines Gas line etc.
Performed UT Thickness Gauge in Drums, Tanks ,Vessels Thermal reactor
To visually inspect the job through Liquid Penetrate Testing & Magnetic Particle Testing and
interpret the result.
Carry out MT Wet Method Yoke type for valve bodies and Welds of T joint fillet Joints.
WORKING EXPERIENCE IN INDIA ( 4 Years )
Name of the Company : GB Engineering Pvt. Ltd., Trichy
Position : NDT Supervisor in Quality Control Department
Duration : From Sep-2005 to Jan-2009
Job Responsibilities
Performed, Ultrasonic Testing &UT Thickness Survey on Pipe lines, Vessels etc.
Performed UT Thickness Gauge on Steam line, jacketed lines Gas line etc.
Performed UT Thickness Gauge in Drums, Tanks ,Vessels Thermal reactor
Performed, Radiography testing Tubes ,Pipes& Pipe Lines
To visually inspect the job through Liquid Penetrate Testing & Magnetic Particle Testing and
interpret the result.
Carry out MT Wet Method Yoke type for valve bodies and Welds of T joint fillet Joints.
Fluorescent method carried out on Station based Testing of Castings and Forgings
Performed, Hardness testing Tubes, Pipes & shell
WORKED IN INDIA (Third party inspection)
Bharat Heavy Electrical Ltd., Trichy
TNPL Ltd., Karur.
GB Engineering Works (P) Ltd, Trichy..
5. Equipment’s handled
Ultrasonic flaw detector’s : Modsonic Einstein-ll
Sonatest D10+
Usm 35X(Flaw Detector)
Usm-Go
DM5E/DM4E(Thickness Gauge-D Meter)
MPI Equipment’s : Electro magnetic Yoke
Radiographic Equipment’s : Delta, Roli , Techups .
Passport Details
Passport Number : G 9930341
Date of Issue : 07/08/2008
Date of Expiry : 06/08/2018
Place of Issue : Tiruchirappalli
Personal Details
Name : B.Vetrivel.
Father’s Name : T.Bangaraju
Sex : Male
Date of Birth : 01/04/1983
Educational Qualification : Higher Secondary
Nationality : Indian
Marital Status : Married.
Languages Known : English, Hindi, Tamil, Telugu
Address for Communication : omandur
Kuppureddi patty (Po),
Krishnarayapuram (TK)
Karur (DT) Pin.639105
Tamil Nadu, South India
Driving licence (india) :LMV in India valid upto :2033
Saudi driving licence :valid upto :2019
Qatar driving licence :Valid.
DECLARATION
I hereby declare that all the above information’s are true to the best of my knowledge and belief.