SlideShare a Scribd company logo
1 of 24
Presenter & Main Author - Dr. Surendra Singh Solanki1 MD

      Co- Authors - M. Loganathan,2 R. Swathika,2
       1Radiation Oncologist, 2Medical Physicists,



   “BA” Smt. Lilaben Chimanlal Parikh Cancer Centre,
                 Navsari, Gujarat, India

             Date of presentation- 30Nov 2012-Kolkata
                    AROICON 2012- Kolkata                  1
Pen tablet
Mouse                2
Computer Science




RO
                                   TPS




        Human Computer Interface
                Mouse                    3
Eclipse Version 8.9

          Contouring



Targets
   &
Organ
At Risk




                 3D View
                                3D View
                                             4
Repetitive Stress Injury




                           5
Modifications in Mouse




                         6
Aim of the Study
 In the era of sophisticated treatment planning, all radiation
  oncologists have to spend much of their time with
  treatment planning systems to contour the targets and
  organ at risks.
 Most common used device for human computer interface is
  mouse (Mo).
 To replace mouse a new device is available in the market
  known as Pen Tablet (PT) from Wacom or i-ball.
 This study was done to find out the effectiveness of these
  devices on a TPS for volume and Time taken for
  contouring.
                                                                  7
Material and Methods
10 patients original CT scans in the Eclipse Treatment
 Planning System (version 8.9) at our centre were
 selected on which IMRT treatment was already
 delivered in this year.
All CT scans do have 3 mm inter-slice distance.
A total of five organs were contoured separately with
 both devices on each CT scan.
Organs were Eyes (left and right), Optic Nerves (left
 and right) and Brain Stem.

                                                          8
Material and Methods.
Time was calculated with stop watch for contouring all
 five organs in one CT scan by both devices.
Volumes of organs were measured on TPS and
 compared between both devices.
During contouring of Organ by right hand through
 Mouse, the middle figure was using the central scroll
 of mouse to move CT slices up and down and while
 contouring with pen Tablet by right hand, left hand
 was using mouse scroll button for up and down
 movements.

                                                          9
Contouring with Mouse




Tamplate for Mouse




                                       10
Contouring with Pen Tablet




Tamplate for Pen Tablet


                                         11
Contouring with both




                       12
Table 1.-Volumes
Volume       Contour by Mouse             Contour by Pen Tablet
              Opt Opt Eye_      Eye_        Opt Opt Eye_ Eye_
CT Scan BS N_Lt N_Rt Lt          Rt    BS N_Lt N_Rt Lt          Rt
   1    20.15 0.39 0.57 8.08    8.59 21.81 0.46 0.49 8.78 7.78
   2    31.26 0.59 0.84 10.67   10.27 30.47 0.88 1.10 10.59 9.60
   3    33.97 0.62 0.66 9.91    9.83 30.82 0.42 0.57 9.47 9.39
   4    26.31 0.43 0.48 9.43    9.73 21.89 0.60 0.35 9.72 9.63
   5    21.78 0.45 0.61 10.29   11.3 19.28 0.54 0.46 10.52 10.29
   6    20.07 0.36 0.51 9.55    8.82 20.43 0.48 0.39 9.20 9.00
   7    22.03 0.23 0.25 9.92    9.74 21.83 0.45 0.43 9.57 9.90
   8    21.41 0.40 0.31 8.64    8.72 20.68 0.54 0.45 8.19 8.61
   9    29.81 0.64 0.44 9.91    10.26 27.04 0.53 0.52 10.44 10.04
  10    18.14 0.53 0.48 9.11    9.28 18.67 0.41 0.53 9.17 9.43
Average 24.49 0.46 0.51 9.55    9.65 23.29 0.53 0.52 9.56 9.36
Table 2- Time taken.
 CT
             Total         Time             Time diff.
scan Time Mo       Time PT       Time diff.
             (sec)         (sec)              (Sec)
 no
  1   4m 23s  263 2m 32s 152 1m 51s            111
  2   4m 32s  272 2m 21s 141 2m 11s            131
  3   5m 52s  352 2m 52s 172       3m 0s       180
  4   4m 42s  282 2m 34s 154       2m 8s       128
  5   5m 54s  354 2m 51s 171       3m 3s       183
  6   4m 46s  286 2m 33s 153 2m 13s            133
  7   4m 53s  293 2m 15s 135 2m 38s            158
  8   4m 18s  258 2m 42s 162 1m 36s            96
  9   4m 49s  289 2m 37s 157 2m 12s            132
 10   4m 15s  255 2m 25s 145 1m 50s            110
Tot. 48m 24s 2904 25m 42s 1542 22m 42s        1362
Tab.3-No. of slices contoured
Volume          Contour by Mouse        Contour by Pen Tablet
                 Opt Opt Eye_ Eye_        Opt Opt Eye_ Eye_
CT Scan    BS    N_Lt N_Rt Lt    Rt  BS N_Lt N_Rt Lt          Rt
   1       15     3     3     9  9   16    2    3     10      9
   2       19     3     3     9  10 18     3    3     10      9
   3       18     3     3     9  9   18    3    3      9      9
   4       17     3 Total slice Contoured
                        3     9  9   16    3    3     10     10
   5       17     3     3    10  12 17     3    2     11     12
   6       16     3   slice by slice 842
                        3    10  10 16     3    3     10      9
   7       18     3     2    11  11 18     3    3     10     10
   8       17     3     2     9  9   17    3    3      9     10
   9       17     2     3    10  10 16     3    3     10     10
  10       15     2     3    10  10 15     2    3     10     11
Average   169     28 28      96  99 167 28 29         99     99
Results
The average volumes of Organs were as follows.
 Brainstem (Mo-24.29 cc: PT-23.29cc), Optic Nerve Left
 (Mo-0.46 cc: PT-0.53 cc), Optic Nerve Right (Mo-0.51
 cc: PT-0.53 cc), Eye Left (Mo-9.55 cc: PT-9.56 cc), Eye
 Right (Mo-9.65 cc: PT-9.36 cc).
Average time taken for contouring of all five organs by
 mouse in ten CT scans was 4 min 50 seconds (290 + 35
 seconds) while time taken by Pen Tablet was 2 min 25
 seconds (154 + 12 seconds).


                                                       16
Results
The total time spent by contouring of all CT scan by
 mouse was 48 min 24 seconds and by PT was 25 min
 42 seconds.
 Hence the total time gain for these small volumes was
 22 min 42 seconds.




                                                          17
Conclusion
The volumes of organs contoured by both devices are
 nearly similar.
 The smoothness in contouring is far superior in pen
 tablet as compared to mouse.
The time utilization is better with Pen tablet as shown
 by this study which is nearly half as compared to
 mouse.
Pen Tablet can be used in contouring for effectively
 utilizing the limited time available with radiation
 oncologist during treatment planning in any busy
 centre.
                                                           18
Practical Working of mouse Vs pen
                     tablet
Discussion of difference.
 Basic working- Ergonomics
 Mouse – point –line -point fashion
 Pen tablet –point-point constant working




                                             19
Take home message
    Pen tablet effectively uses limited time with more
     smoothness.




     2 Dimensional EBRT                             3D Conformal EBRT

2D Pic -Curtsey- Prof. Dr O. P Singh, GMC Bhopal.                       20
Future of Radiation Contouring




Curtsey -Dr Martin Fuss MD , Oregon Health & Science University , Portland, USA.
And Wacom Cintiq                                                               21
My Pen Tablet- from i-Ball.
                    My Pen tablet




> 300 patients are treated with help of contouring done by this pen tablet.

                                                                              22
 My Personal Experience


1. With mouse Contouring targets + OAR –Slice
                 by Slice- 4 to 6 hours.
 2. With pen tablet Contouring targets + OAR –
              Slice by Slice- 2 to 3 hours
3. With pen tablet Contouring Target + OAR- 2th
   or 3rd slice contouring and interpolation then=
               45 minutes to 1.5 hours.
                                               23
Treated > 600 patients in two years




Established since Jan 2011                                24

More Related Content

What's hot

Carcinoma anal canal
Carcinoma anal canalCarcinoma anal canal
Carcinoma anal canalMegha Prem
 
Role of Radiation Therapy for Lung Cancer
Role of Radiation Therapy for Lung CancerRole of Radiation Therapy for Lung Cancer
Role of Radiation Therapy for Lung Cancerspa718
 
NOV 2022 ONCOLOGY CARTOONS .pdf
NOV 2022 ONCOLOGY CARTOONS .pdfNOV 2022 ONCOLOGY CARTOONS .pdf
NOV 2022 ONCOLOGY CARTOONS .pdfKanhu Charan
 
Adaptive Radiotherapy at GenesisCare UK
Adaptive Radiotherapy at GenesisCare UKAdaptive Radiotherapy at GenesisCare UK
Adaptive Radiotherapy at GenesisCare UKGenesisCareUK
 
Bladder preservation for CA Urinary Bladder
Bladder preservation for CA Urinary BladderBladder preservation for CA Urinary Bladder
Bladder preservation for CA Urinary BladderAnil Gupta
 
Prostate cancer radiotherapy
Prostate cancer radiotherapyProstate cancer radiotherapy
Prostate cancer radiotherapymohamed alhefny
 
Role of SBRT in lung cancer
Role of SBRT in lung cancerRole of SBRT in lung cancer
Role of SBRT in lung cancerDrAyush Garg
 
TARGET DELINEATION OF SOFT TISSUE SARCOMA
TARGET DELINEATION OF SOFT TISSUE SARCOMATARGET DELINEATION OF SOFT TISSUE SARCOMA
TARGET DELINEATION OF SOFT TISSUE SARCOMAKanhu Charan
 
Nuclear medicine application in neuroendocrine tumors (net)
Nuclear medicine application in neuroendocrine tumors (net)Nuclear medicine application in neuroendocrine tumors (net)
Nuclear medicine application in neuroendocrine tumors (net)Ramin Sadeghi
 
Radiation for the Treatment of Bladder Cancer
Radiation for the Treatment of Bladder CancerRadiation for the Treatment of Bladder Cancer
Radiation for the Treatment of Bladder CancerRobert J Miller MD
 
Bladder preservation in mibc
Bladder preservation in mibcBladder preservation in mibc
Bladder preservation in mibcRitika Harjani
 
Triple negative breast cancer-new developments
Triple negative breast cancer-new developmentsTriple negative breast cancer-new developments
Triple negative breast cancer-new developmentsNikolaosDiamantopoul1
 
Bonescan 22-08-2014
Bonescan 22-08-2014Bonescan 22-08-2014
Bonescan 22-08-2014Amol Gulhane
 
Radiotherapy in hepatocellular carcinomas
Radiotherapy in hepatocellular carcinomasRadiotherapy in hepatocellular carcinomas
Radiotherapy in hepatocellular carcinomasPratap Tiwari
 

What's hot (20)

Carcinoma anal canal
Carcinoma anal canalCarcinoma anal canal
Carcinoma anal canal
 
Role of Radiation Therapy for Lung Cancer
Role of Radiation Therapy for Lung CancerRole of Radiation Therapy for Lung Cancer
Role of Radiation Therapy for Lung Cancer
 
NOV 2022 ONCOLOGY CARTOONS .pdf
NOV 2022 ONCOLOGY CARTOONS .pdfNOV 2022 ONCOLOGY CARTOONS .pdf
NOV 2022 ONCOLOGY CARTOONS .pdf
 
Adaptive Radiotherapy at GenesisCare UK
Adaptive Radiotherapy at GenesisCare UKAdaptive Radiotherapy at GenesisCare UK
Adaptive Radiotherapy at GenesisCare UK
 
Bladder preservation for CA Urinary Bladder
Bladder preservation for CA Urinary BladderBladder preservation for CA Urinary Bladder
Bladder preservation for CA Urinary Bladder
 
Pancreatic ca adjuvant badheeb
Pancreatic ca  adjuvant badheebPancreatic ca  adjuvant badheeb
Pancreatic ca adjuvant badheeb
 
Carcinoma of unknown primary
Carcinoma of unknown primaryCarcinoma of unknown primary
Carcinoma of unknown primary
 
Prostate cancer radiotherapy
Prostate cancer radiotherapyProstate cancer radiotherapy
Prostate cancer radiotherapy
 
Role of SBRT in lung cancer
Role of SBRT in lung cancerRole of SBRT in lung cancer
Role of SBRT in lung cancer
 
Stomach adjuvant rt
Stomach adjuvant rtStomach adjuvant rt
Stomach adjuvant rt
 
TARGET DELINEATION OF SOFT TISSUE SARCOMA
TARGET DELINEATION OF SOFT TISSUE SARCOMATARGET DELINEATION OF SOFT TISSUE SARCOMA
TARGET DELINEATION OF SOFT TISSUE SARCOMA
 
Nuclear medicine application in neuroendocrine tumors (net)
Nuclear medicine application in neuroendocrine tumors (net)Nuclear medicine application in neuroendocrine tumors (net)
Nuclear medicine application in neuroendocrine tumors (net)
 
Exactrac 6D imaging overview
Exactrac 6D imaging overviewExactrac 6D imaging overview
Exactrac 6D imaging overview
 
Cancer imaging
Cancer imagingCancer imaging
Cancer imaging
 
Radiation for the Treatment of Bladder Cancer
Radiation for the Treatment of Bladder CancerRadiation for the Treatment of Bladder Cancer
Radiation for the Treatment of Bladder Cancer
 
Bladder preservation in mibc
Bladder preservation in mibcBladder preservation in mibc
Bladder preservation in mibc
 
Triple negative breast cancer-new developments
Triple negative breast cancer-new developmentsTriple negative breast cancer-new developments
Triple negative breast cancer-new developments
 
Bonescan 22-08-2014
Bonescan 22-08-2014Bonescan 22-08-2014
Bonescan 22-08-2014
 
Radiotherapy in hepatocellular carcinomas
Radiotherapy in hepatocellular carcinomasRadiotherapy in hepatocellular carcinomas
Radiotherapy in hepatocellular carcinomas
 
Breast Cancer Radiation Therapy: RT Plan evaluation & Recent Advances - 4DCT ...
Breast Cancer Radiation Therapy: RT Plan evaluation & Recent Advances - 4DCT ...Breast Cancer Radiation Therapy: RT Plan evaluation & Recent Advances - 4DCT ...
Breast Cancer Radiation Therapy: RT Plan evaluation & Recent Advances - 4DCT ...
 

Similar to Pen tablet vs mouse for Contouring OAR and targets

Cancer Detection in 10 seconds by CANCER PEN
Cancer Detection in 10 seconds by CANCER PENCancer Detection in 10 seconds by CANCER PEN
Cancer Detection in 10 seconds by CANCER PENNalesh Jadhav
 
Nuclear Medicine - PET/CT
Nuclear Medicine - PET/CTNuclear Medicine - PET/CT
Nuclear Medicine - PET/CT@Saudi_nmc
 
[In Clinical Practice] Usiakimi Igbaseimokumo - Brain CT Scans in Clinical Pr...
[In Clinical Practice] Usiakimi Igbaseimokumo - Brain CT Scans in Clinical Pr...[In Clinical Practice] Usiakimi Igbaseimokumo - Brain CT Scans in Clinical Pr...
[In Clinical Practice] Usiakimi Igbaseimokumo - Brain CT Scans in Clinical Pr...LThNhQunh12
 
the top five ways medical physics has changed healthcare
the top five ways medical physics has changed healthcarethe top five ways medical physics has changed healthcare
the top five ways medical physics has changed healthcareSumaiaHered
 
Three-dimensional imaging techniques: A literature review By; Orhan Hakki Ka...
Three-dimensional imaging techniques: A literature review  By; Orhan Hakki Ka...Three-dimensional imaging techniques: A literature review  By; Orhan Hakki Ka...
Three-dimensional imaging techniques: A literature review By; Orhan Hakki Ka...Dr. Yahya Alogaibi
 
3D Visualisation System Report
3D Visualisation System Report3D Visualisation System Report
3D Visualisation System Reportmeducationdotnet
 
Early Detection of Cancerous Lung Nodules from Computed Tomography Images
Early Detection of Cancerous Lung Nodules from Computed Tomography ImagesEarly Detection of Cancerous Lung Nodules from Computed Tomography Images
Early Detection of Cancerous Lung Nodules from Computed Tomography ImagesCSCJournals
 
Analysis of the Difference between the Normal Vision and the Experiencing Cat...
Analysis of the Difference between the Normal Vision and the Experiencing Cat...Analysis of the Difference between the Normal Vision and the Experiencing Cat...
Analysis of the Difference between the Normal Vision and the Experiencing Cat...IJERA Editor
 
Science Project Skelatal Scan
Science Project Skelatal ScanScience Project Skelatal Scan
Science Project Skelatal Scanguesta8cada
 
Ben Turner - MRI workshop
Ben Turner -  MRI workshopBen Turner -  MRI workshop
Ben Turner - MRI workshopMS Trust
 
CBCT anatomical structures
CBCT anatomical structuresCBCT anatomical structures
CBCT anatomical structuressarahelgammal2
 
aguidefordelineationoflymphnodalclinicaltargetvolumeinradiationtherapy-100218...
aguidefordelineationoflymphnodalclinicaltargetvolumeinradiationtherapy-100218...aguidefordelineationoflymphnodalclinicaltargetvolumeinradiationtherapy-100218...
aguidefordelineationoflymphnodalclinicaltargetvolumeinradiationtherapy-100218...AsifaAndleeb
 
Reliability of Three-dimensional Photonic Scanner Anthropometry Performed by ...
Reliability of Three-dimensional Photonic Scanner Anthropometry Performed by ...Reliability of Three-dimensional Photonic Scanner Anthropometry Performed by ...
Reliability of Three-dimensional Photonic Scanner Anthropometry Performed by ...CSCJournals
 

Similar to Pen tablet vs mouse for Contouring OAR and targets (20)

Cancer Detection in 10 seconds by CANCER PEN
Cancer Detection in 10 seconds by CANCER PENCancer Detection in 10 seconds by CANCER PEN
Cancer Detection in 10 seconds by CANCER PEN
 
Korte-PachymetryACT13
Korte-PachymetryACT13Korte-PachymetryACT13
Korte-PachymetryACT13
 
Computed Tomography
Computed TomographyComputed Tomography
Computed Tomography
 
Nuclear Medicine - PET/CT
Nuclear Medicine - PET/CTNuclear Medicine - PET/CT
Nuclear Medicine - PET/CT
 
[In Clinical Practice] Usiakimi Igbaseimokumo - Brain CT Scans in Clinical Pr...
[In Clinical Practice] Usiakimi Igbaseimokumo - Brain CT Scans in Clinical Pr...[In Clinical Practice] Usiakimi Igbaseimokumo - Brain CT Scans in Clinical Pr...
[In Clinical Practice] Usiakimi Igbaseimokumo - Brain CT Scans in Clinical Pr...
 
3D Reconstruction of Peripheral Nerves Based on Calcium Chloride Enhanced Mic...
3D Reconstruction of Peripheral Nerves Based on Calcium Chloride Enhanced Mic...3D Reconstruction of Peripheral Nerves Based on Calcium Chloride Enhanced Mic...
3D Reconstruction of Peripheral Nerves Based on Calcium Chloride Enhanced Mic...
 
the top five ways medical physics has changed healthcare
the top five ways medical physics has changed healthcarethe top five ways medical physics has changed healthcare
the top five ways medical physics has changed healthcare
 
Three-dimensional imaging techniques: A literature review By; Orhan Hakki Ka...
Three-dimensional imaging techniques: A literature review  By; Orhan Hakki Ka...Three-dimensional imaging techniques: A literature review  By; Orhan Hakki Ka...
Three-dimensional imaging techniques: A literature review By; Orhan Hakki Ka...
 
Ct pns
Ct pnsCt pns
Ct pns
 
3D Visualisation System Report
3D Visualisation System Report3D Visualisation System Report
3D Visualisation System Report
 
Early Detection of Cancerous Lung Nodules from Computed Tomography Images
Early Detection of Cancerous Lung Nodules from Computed Tomography ImagesEarly Detection of Cancerous Lung Nodules from Computed Tomography Images
Early Detection of Cancerous Lung Nodules from Computed Tomography Images
 
Analysis of the Difference between the Normal Vision and the Experiencing Cat...
Analysis of the Difference between the Normal Vision and the Experiencing Cat...Analysis of the Difference between the Normal Vision and the Experiencing Cat...
Analysis of the Difference between the Normal Vision and the Experiencing Cat...
 
SCT course
SCT courseSCT course
SCT course
 
Science Project Skelatal Scan
Science Project Skelatal ScanScience Project Skelatal Scan
Science Project Skelatal Scan
 
Ben Turner - MRI workshop
Ben Turner -  MRI workshopBen Turner -  MRI workshop
Ben Turner - MRI workshop
 
CBCT anatomical structures
CBCT anatomical structuresCBCT anatomical structures
CBCT anatomical structures
 
OCT in Ophthalmology
OCT in OphthalmologyOCT in Ophthalmology
OCT in Ophthalmology
 
aguidefordelineationoflymphnodalclinicaltargetvolumeinradiationtherapy-100218...
aguidefordelineationoflymphnodalclinicaltargetvolumeinradiationtherapy-100218...aguidefordelineationoflymphnodalclinicaltargetvolumeinradiationtherapy-100218...
aguidefordelineationoflymphnodalclinicaltargetvolumeinradiationtherapy-100218...
 
Lymphnodes
LymphnodesLymphnodes
Lymphnodes
 
Reliability of Three-dimensional Photonic Scanner Anthropometry Performed by ...
Reliability of Three-dimensional Photonic Scanner Anthropometry Performed by ...Reliability of Three-dimensional Photonic Scanner Anthropometry Performed by ...
Reliability of Three-dimensional Photonic Scanner Anthropometry Performed by ...
 

Recently uploaded

Call Girls Ooty Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Ooty Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Ooty Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Ooty Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
💎VVIP Kolkata Call Girls Parganas🩱7001035870🩱Independent Girl ( Ac Rooms Avai...
💎VVIP Kolkata Call Girls Parganas🩱7001035870🩱Independent Girl ( Ac Rooms Avai...💎VVIP Kolkata Call Girls Parganas🩱7001035870🩱Independent Girl ( Ac Rooms Avai...
💎VVIP Kolkata Call Girls Parganas🩱7001035870🩱Independent Girl ( Ac Rooms Avai...Taniya Sharma
 
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...narwatsonia7
 
VIP Call Girls Tirunelveli Aaradhya 8250192130 Independent Escort Service Tir...
VIP Call Girls Tirunelveli Aaradhya 8250192130 Independent Escort Service Tir...VIP Call Girls Tirunelveli Aaradhya 8250192130 Independent Escort Service Tir...
VIP Call Girls Tirunelveli Aaradhya 8250192130 Independent Escort Service Tir...narwatsonia7
 
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Service
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort ServicePremium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Service
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Servicevidya singh
 
(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...
(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...
(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...indiancallgirl4rent
 
All Time Service Available Call Girls Marine Drive 📳 9820252231 For 18+ VIP C...
All Time Service Available Call Girls Marine Drive 📳 9820252231 For 18+ VIP C...All Time Service Available Call Girls Marine Drive 📳 9820252231 For 18+ VIP C...
All Time Service Available Call Girls Marine Drive 📳 9820252231 For 18+ VIP C...Arohi Goyal
 
VIP Service Call Girls Sindhi Colony 📳 7877925207 For 18+ VIP Call Girl At Th...
VIP Service Call Girls Sindhi Colony 📳 7877925207 For 18+ VIP Call Girl At Th...VIP Service Call Girls Sindhi Colony 📳 7877925207 For 18+ VIP Call Girl At Th...
VIP Service Call Girls Sindhi Colony 📳 7877925207 For 18+ VIP Call Girl At Th...jageshsingh5554
 
Call Girl Number in Panvel Mumbai📲 9833363713 💞 Full Night Enjoy
Call Girl Number in Panvel Mumbai📲 9833363713 💞 Full Night EnjoyCall Girl Number in Panvel Mumbai📲 9833363713 💞 Full Night Enjoy
Call Girl Number in Panvel Mumbai📲 9833363713 💞 Full Night Enjoybabeytanya
 
Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...
Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...
Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...hotbabesbook
 
Call Girls Kochi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Kochi Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Kochi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Kochi Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
Lucknow Call girls - 8800925952 - 24x7 service with hotel room
Lucknow Call girls - 8800925952 - 24x7 service with hotel roomLucknow Call girls - 8800925952 - 24x7 service with hotel room
Lucknow Call girls - 8800925952 - 24x7 service with hotel roomdiscovermytutordmt
 
Bangalore Call Girl Whatsapp Number 100% Complete Your Sexual Needs
Bangalore Call Girl Whatsapp Number 100% Complete Your Sexual NeedsBangalore Call Girl Whatsapp Number 100% Complete Your Sexual Needs
Bangalore Call Girl Whatsapp Number 100% Complete Your Sexual NeedsGfnyt
 
Call Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
Call Girls Darjeeling Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Darjeeling Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Darjeeling Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Darjeeling Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
VIP Russian Call Girls in Varanasi Samaira 8250192130 Independent Escort Serv...
VIP Russian Call Girls in Varanasi Samaira 8250192130 Independent Escort Serv...VIP Russian Call Girls in Varanasi Samaira 8250192130 Independent Escort Serv...
VIP Russian Call Girls in Varanasi Samaira 8250192130 Independent Escort Serv...Neha Kaur
 
Call Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on Delivery
Call Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on DeliveryCall Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on Delivery
Call Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on Deliverynehamumbai
 
Call Girls Nagpur Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Nagpur Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Nagpur Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Nagpur Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 

Recently uploaded (20)

Call Girls Ooty Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Ooty Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Ooty Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Ooty Just Call 9907093804 Top Class Call Girl Service Available
 
💎VVIP Kolkata Call Girls Parganas🩱7001035870🩱Independent Girl ( Ac Rooms Avai...
💎VVIP Kolkata Call Girls Parganas🩱7001035870🩱Independent Girl ( Ac Rooms Avai...💎VVIP Kolkata Call Girls Parganas🩱7001035870🩱Independent Girl ( Ac Rooms Avai...
💎VVIP Kolkata Call Girls Parganas🩱7001035870🩱Independent Girl ( Ac Rooms Avai...
 
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
 
VIP Call Girls Tirunelveli Aaradhya 8250192130 Independent Escort Service Tir...
VIP Call Girls Tirunelveli Aaradhya 8250192130 Independent Escort Service Tir...VIP Call Girls Tirunelveli Aaradhya 8250192130 Independent Escort Service Tir...
VIP Call Girls Tirunelveli Aaradhya 8250192130 Independent Escort Service Tir...
 
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
 
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Service
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort ServicePremium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Service
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Service
 
(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...
(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...
(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...
 
All Time Service Available Call Girls Marine Drive 📳 9820252231 For 18+ VIP C...
All Time Service Available Call Girls Marine Drive 📳 9820252231 For 18+ VIP C...All Time Service Available Call Girls Marine Drive 📳 9820252231 For 18+ VIP C...
All Time Service Available Call Girls Marine Drive 📳 9820252231 For 18+ VIP C...
 
VIP Service Call Girls Sindhi Colony 📳 7877925207 For 18+ VIP Call Girl At Th...
VIP Service Call Girls Sindhi Colony 📳 7877925207 For 18+ VIP Call Girl At Th...VIP Service Call Girls Sindhi Colony 📳 7877925207 For 18+ VIP Call Girl At Th...
VIP Service Call Girls Sindhi Colony 📳 7877925207 For 18+ VIP Call Girl At Th...
 
Call Girl Number in Panvel Mumbai📲 9833363713 💞 Full Night Enjoy
Call Girl Number in Panvel Mumbai📲 9833363713 💞 Full Night EnjoyCall Girl Number in Panvel Mumbai📲 9833363713 💞 Full Night Enjoy
Call Girl Number in Panvel Mumbai📲 9833363713 💞 Full Night Enjoy
 
Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...
Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...
Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...
 
Call Girls Kochi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Kochi Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Kochi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Kochi Just Call 9907093804 Top Class Call Girl Service Available
 
Lucknow Call girls - 8800925952 - 24x7 service with hotel room
Lucknow Call girls - 8800925952 - 24x7 service with hotel roomLucknow Call girls - 8800925952 - 24x7 service with hotel room
Lucknow Call girls - 8800925952 - 24x7 service with hotel room
 
Bangalore Call Girl Whatsapp Number 100% Complete Your Sexual Needs
Bangalore Call Girl Whatsapp Number 100% Complete Your Sexual NeedsBangalore Call Girl Whatsapp Number 100% Complete Your Sexual Needs
Bangalore Call Girl Whatsapp Number 100% Complete Your Sexual Needs
 
Call Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service Available
 
Call Girls Darjeeling Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Darjeeling Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Darjeeling Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Darjeeling Just Call 9907093804 Top Class Call Girl Service Available
 
VIP Russian Call Girls in Varanasi Samaira 8250192130 Independent Escort Serv...
VIP Russian Call Girls in Varanasi Samaira 8250192130 Independent Escort Serv...VIP Russian Call Girls in Varanasi Samaira 8250192130 Independent Escort Serv...
VIP Russian Call Girls in Varanasi Samaira 8250192130 Independent Escort Serv...
 
Call Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on Delivery
Call Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on DeliveryCall Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on Delivery
Call Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on Delivery
 
Russian Call Girls in Delhi Tanvi ➡️ 9711199012 💋📞 Independent Escort Service...
Russian Call Girls in Delhi Tanvi ➡️ 9711199012 💋📞 Independent Escort Service...Russian Call Girls in Delhi Tanvi ➡️ 9711199012 💋📞 Independent Escort Service...
Russian Call Girls in Delhi Tanvi ➡️ 9711199012 💋📞 Independent Escort Service...
 
Call Girls Nagpur Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Nagpur Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Nagpur Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Nagpur Just Call 9907093804 Top Class Call Girl Service Available
 

Pen tablet vs mouse for Contouring OAR and targets

  • 1. Presenter & Main Author - Dr. Surendra Singh Solanki1 MD Co- Authors - M. Loganathan,2 R. Swathika,2 1Radiation Oncologist, 2Medical Physicists, “BA” Smt. Lilaben Chimanlal Parikh Cancer Centre, Navsari, Gujarat, India Date of presentation- 30Nov 2012-Kolkata AROICON 2012- Kolkata 1
  • 3. Computer Science RO TPS Human Computer Interface Mouse 3
  • 4. Eclipse Version 8.9 Contouring Targets & Organ At Risk 3D View 3D View 4
  • 7. Aim of the Study  In the era of sophisticated treatment planning, all radiation oncologists have to spend much of their time with treatment planning systems to contour the targets and organ at risks.  Most common used device for human computer interface is mouse (Mo).  To replace mouse a new device is available in the market known as Pen Tablet (PT) from Wacom or i-ball.  This study was done to find out the effectiveness of these devices on a TPS for volume and Time taken for contouring. 7
  • 8. Material and Methods 10 patients original CT scans in the Eclipse Treatment Planning System (version 8.9) at our centre were selected on which IMRT treatment was already delivered in this year. All CT scans do have 3 mm inter-slice distance. A total of five organs were contoured separately with both devices on each CT scan. Organs were Eyes (left and right), Optic Nerves (left and right) and Brain Stem. 8
  • 9. Material and Methods. Time was calculated with stop watch for contouring all five organs in one CT scan by both devices. Volumes of organs were measured on TPS and compared between both devices. During contouring of Organ by right hand through Mouse, the middle figure was using the central scroll of mouse to move CT slices up and down and while contouring with pen Tablet by right hand, left hand was using mouse scroll button for up and down movements. 9
  • 11. Contouring with Pen Tablet Tamplate for Pen Tablet 11
  • 13. Table 1.-Volumes Volume Contour by Mouse Contour by Pen Tablet Opt Opt Eye_ Eye_ Opt Opt Eye_ Eye_ CT Scan BS N_Lt N_Rt Lt Rt BS N_Lt N_Rt Lt Rt 1 20.15 0.39 0.57 8.08 8.59 21.81 0.46 0.49 8.78 7.78 2 31.26 0.59 0.84 10.67 10.27 30.47 0.88 1.10 10.59 9.60 3 33.97 0.62 0.66 9.91 9.83 30.82 0.42 0.57 9.47 9.39 4 26.31 0.43 0.48 9.43 9.73 21.89 0.60 0.35 9.72 9.63 5 21.78 0.45 0.61 10.29 11.3 19.28 0.54 0.46 10.52 10.29 6 20.07 0.36 0.51 9.55 8.82 20.43 0.48 0.39 9.20 9.00 7 22.03 0.23 0.25 9.92 9.74 21.83 0.45 0.43 9.57 9.90 8 21.41 0.40 0.31 8.64 8.72 20.68 0.54 0.45 8.19 8.61 9 29.81 0.64 0.44 9.91 10.26 27.04 0.53 0.52 10.44 10.04 10 18.14 0.53 0.48 9.11 9.28 18.67 0.41 0.53 9.17 9.43 Average 24.49 0.46 0.51 9.55 9.65 23.29 0.53 0.52 9.56 9.36
  • 14. Table 2- Time taken. CT Total Time Time diff. scan Time Mo Time PT Time diff. (sec) (sec) (Sec) no 1 4m 23s 263 2m 32s 152 1m 51s 111 2 4m 32s 272 2m 21s 141 2m 11s 131 3 5m 52s 352 2m 52s 172 3m 0s 180 4 4m 42s 282 2m 34s 154 2m 8s 128 5 5m 54s 354 2m 51s 171 3m 3s 183 6 4m 46s 286 2m 33s 153 2m 13s 133 7 4m 53s 293 2m 15s 135 2m 38s 158 8 4m 18s 258 2m 42s 162 1m 36s 96 9 4m 49s 289 2m 37s 157 2m 12s 132 10 4m 15s 255 2m 25s 145 1m 50s 110 Tot. 48m 24s 2904 25m 42s 1542 22m 42s 1362
  • 15. Tab.3-No. of slices contoured Volume Contour by Mouse Contour by Pen Tablet Opt Opt Eye_ Eye_ Opt Opt Eye_ Eye_ CT Scan BS N_Lt N_Rt Lt Rt BS N_Lt N_Rt Lt Rt 1 15 3 3 9 9 16 2 3 10 9 2 19 3 3 9 10 18 3 3 10 9 3 18 3 3 9 9 18 3 3 9 9 4 17 3 Total slice Contoured 3 9 9 16 3 3 10 10 5 17 3 3 10 12 17 3 2 11 12 6 16 3 slice by slice 842 3 10 10 16 3 3 10 9 7 18 3 2 11 11 18 3 3 10 10 8 17 3 2 9 9 17 3 3 9 10 9 17 2 3 10 10 16 3 3 10 10 10 15 2 3 10 10 15 2 3 10 11 Average 169 28 28 96 99 167 28 29 99 99
  • 16. Results The average volumes of Organs were as follows. Brainstem (Mo-24.29 cc: PT-23.29cc), Optic Nerve Left (Mo-0.46 cc: PT-0.53 cc), Optic Nerve Right (Mo-0.51 cc: PT-0.53 cc), Eye Left (Mo-9.55 cc: PT-9.56 cc), Eye Right (Mo-9.65 cc: PT-9.36 cc). Average time taken for contouring of all five organs by mouse in ten CT scans was 4 min 50 seconds (290 + 35 seconds) while time taken by Pen Tablet was 2 min 25 seconds (154 + 12 seconds). 16
  • 17. Results The total time spent by contouring of all CT scan by mouse was 48 min 24 seconds and by PT was 25 min 42 seconds.  Hence the total time gain for these small volumes was 22 min 42 seconds. 17
  • 18. Conclusion The volumes of organs contoured by both devices are nearly similar.  The smoothness in contouring is far superior in pen tablet as compared to mouse. The time utilization is better with Pen tablet as shown by this study which is nearly half as compared to mouse. Pen Tablet can be used in contouring for effectively utilizing the limited time available with radiation oncologist during treatment planning in any busy centre. 18
  • 19. Practical Working of mouse Vs pen tablet Discussion of difference.  Basic working- Ergonomics  Mouse – point –line -point fashion  Pen tablet –point-point constant working 19
  • 20. Take home message  Pen tablet effectively uses limited time with more smoothness. 2 Dimensional EBRT 3D Conformal EBRT 2D Pic -Curtsey- Prof. Dr O. P Singh, GMC Bhopal. 20
  • 21. Future of Radiation Contouring Curtsey -Dr Martin Fuss MD , Oregon Health & Science University , Portland, USA. And Wacom Cintiq 21
  • 22. My Pen Tablet- from i-Ball. My Pen tablet > 300 patients are treated with help of contouring done by this pen tablet. 22
  • 23.  My Personal Experience 1. With mouse Contouring targets + OAR –Slice by Slice- 4 to 6 hours. 2. With pen tablet Contouring targets + OAR – Slice by Slice- 2 to 3 hours 3. With pen tablet Contouring Target + OAR- 2th or 3rd slice contouring and interpolation then= 45 minutes to 1.5 hours. 23
  • 24. Treated > 600 patients in two years Established since Jan 2011 24

Editor's Notes

  1. Right now I am utilising mouse and pen tablet simultaneously for this presentation
  2. The developments in computer science have given Radiation oncologists a platform to evolve themselves from 2Dimentional Radiation practice to three dimensional Conformal radiotherapy.The whole interaction between radiation oncologist and treatment planning system is done through one human computer interface known as mouse.
  3. Dictionary meaning of contouring is to outline the organ, or structure For a Radiation oncologist this is most important step in the planning process other then clinical planning on x ray or ct simulator.. This process is well executed with help of mouse on TPS by contouring slice by slice and combining all contours will give 3D view.
  4. But there are certain drawbacks of excess utilization of mouse. It can give repetitive stress injury to index finger, wrist, arm and shoulder. I am sure those radiation oncologist in the audience who have tried to make their work fast with mouse must have experienced this sort of injury.
  5. After understanding of ergonomics of human use, the technical enhancements in human computer interface have given many modifications in mouse. Pen tablet is one of them which is more ergonomically suited to human anatomy. This is mouse in form of pen which is mostly used for drawing on computers.
  6. The Aim of this comparative study is to find effectiveness of mouse verses pen tablet by utilising volume and time as criteria.
  7. At our centre we practice 3DCRT and IMRT for radiation therapy.We have selected ten patients IMRT CT scan with 3mm inter slice distance. We have chosen five organs both eyes, both optic nerves and brain stem as organs to be contoured by mouse and pen tablet separately slice by slice.
  8. Time taken by both devices was calculated by stop watch. Volumes of all organs were found on TPS and compared.No of slices used for each organ was noted.
  9. A structural template for mouse and pen tablet was made and introduced in context window in eclipse.This is contouring from mouse.
  10. This slice shows contouring of pen tablet
  11. And now slices shows fusion of mouse and pen tablet contours.
  12. The tabulation of volumes. Head on comparison of volumes of respective organs are nearly similar. The Average volumes are also nearly similar.
  13. But the time taken by both devices differ drastically. The mouse has taken 4 to 5 minutes for contouring all five organs where as pen tablet has taken 2 to 3 minutes only.The addition of time taken by both devices can clearly show that time utilizes by pen tablet(25 min 42 sec) is nearly half in comparison to mouse (48 min 24 sec.)
  14. Tabulation of no of slices contoured per organ. The total slices contoured were 842.
  15. This is the result of our study volumes are similar.
  16. Timeutilised is better with pen tablet.
  17. The conclusions- the volumes of organs contoured were nearly similar, smoothness is superior in pen tablet, I am explaining in next slide. and Time utilised is better with pen tablet which effectively uses limited time.
  18. Let me explain practically with both devices.The contouring with mouse is done as deposition of points around a organ. And all these points are joined by a line. Where as contouring with pen tablet is deposition of points along with direction pen tablet movement. That’s why the smoothness is contouring by pen tablet is superior to mouse.
  19. Take home message : Pen tablet effectively uses limited time with more smoothness.We all radiation oncologist have evolved from outer skin marking in 2D era to internal organ contouring 3D through mouse. this transformation from 2D to 3D has taken much of our time in contouring. Its my humble request to all radiation oncologist of India to kindly use pen tablet or similar device in future to effectively utilize your limited time.
  20. In future we will be able to contour directly on the Computer screen with help pen based input device.
  21. This is my pen tablet from I ball. Because of it, We are able to completed full contouring of > 300 patients at our centre.
  22. Thanks a lot from me and my whole radiation therapy team at BaSmt LC Parikh cancer centre Navsari Gujarat.