Example residential project
1.
2. YOUR LOGO
Your Address
Your Contact Info
Confidentiality Statement:
This drawing is the property of
Your Company. This information is
confidential and is to be used only
in connection with work described
by Shorebreak. No part is to be
discolosed to others without written
permission from Shorebreak.
Your Company
LIC# Your Licence Number
EXP: -/-/-
X_________________________
Project Address.
YOUR PROJECT
NAME
Your Company
Title Sheet
T101
10/7/2014 6:11:49 PM
To scale on 24x36 paper
Project Name
Project Address
SOLAR ELECTRIC SYSTEM PROJECT - Project Size
VICINITY MAP: PROJECT SCOPE: DRAWING INDEX PERMITTING / PLANNING NOTES:
SOLAR ELECTRIC SYSTEM
THIS PROJECT ENTAILS THE INSTALLATION OF A
PHOTOVOLTAIC SYSTEM AT THE DENIER RESIDENCE. THE
SYSTEM WILL NOT BE A NET ELECTRICITY EXPORTER TO
THE UTILITY GRID.
THIS INSTALLATION CONSISTS OF A NEW ROOF MOUNTED
PHOTOVOLTAIC (PV)SYSTEM (SEE E101). THE PV SYSTEM
IS STATIC MOUNTED.
THIS SYSTEM WILL BE INTERCONNECTED TO AND WILL BE
OPERATED IN PARALLEL WITH THE SCE ELECTRIC GRID
PER THE REQUIREMENTS OF THE NATIONAL ELECTRICAL
CODE AND UTILITY INTERCONNECT AGREEMENT
CONDITIONS OF APPROVAL:
1. ALL CONSTRUCTION SHALL OCCUR BETWEEN THE
HOURS OF 7AM & 7PM, EXCEPT FOR THE PURPOSE OF
EMERGENCIES.
1. THIS PV SYSTEM INSTALLATION IS SUBJECT TO INSPECTION BY THE CITY BUILDING
OFFICIALS AND Your Company
2. THIS PROJECT SHALL CONFORM TO THE FOLLOWING CODE VERSIONS:
2013 CALIFORNIA BUILDING CODE (CBC 2013)
2013 CALIFORNIA ELECTRIC CODE (CEC 2013)
2013 CALIFORNIA FIRE CODE (CFC 2013)
USE ONLY APPROVED AND LISTED APPLIANCES, DEVICES, HARDWARE AND COPPER WIRE
FOR BRANCH CIRCUITS SUITABLE FOR INTENDED USE
Sheet # Sheet Name
T101 Title Sheet
T102 Notes
D101 Layout & Details
E101 Elect'l Diagrams
E102 Spec Sheets
AERIAL PHOTO: PROJECT TEAM:
SITE CONTACT:
Client and Client Info
CONTRACTOR / DESIGN FIRM:
Your Company and Contact Info
ARRAY #
ARRAY 1
BLDG.
SFR
AREA
(SQFT)
576
# PANELS
33
ARRAY DETAILS:
OCCUPANCY
/TYPE*
R3 / V-B
*OCCUPANCY GROUP AND TYPE OF
CONSTRUCTION PER 2010 CBC
Your Site
# OF
FLOORS
2
Your Site
SITE ADDRESS:
Your Site
No. Description Date
3. 3
2
(20) Suniva 260 Watt modules
#OPT260-60-4-1B0 (65.04" x 38.66")
(20) Enphase Micro Inverters 215W
#M215-60-2LL-S2X
Flush Mount system
5 degree tilt, 145 degree Azimuth
Roofing: Compisition Shingle
Rafters: 2x8 @ 24" O.C.
LEGEND
100A Sub Panel for Inverters
SP
AC Disconnect: 60A/240V
AC Square D# DU222RB
200A main/ 200A buss
Main panel & Utility electrical
service
MP
MP AC
Property Line
(N) AC wiring,
(1) #10 AWG ground
conductor in (N) 3/4" min. RMC
D101
Property Line
Property Line
Property Line
4.B
D101
4.A
D101
SP
3' Fire Setback 3' Fire Setback
D101
(13) Suniva 260 Watt modules
#OPT260-60-4-1B0 (65.04" x 38.66")
(13) Enphase Micro Inverters 215W
#M215-60-2LL-S2X
Tilt Rack system
5 degree tilt, 235 degree Azimuth
Roofing: Compisition Shingle
Rafters: 2x8 @ 24" O.C.
2' - 0"
TYP.
(E) 2x8 ROOF RAFTERS
ROOFING MATERIAL:
COMP. SHINGLE
@ 24" O.C.
QUICKMOUNT PV TYP
SEE DETAIL 5/D101
27' - 1"
13' - 3"
SOLAR MOUNT
RACKING TYP
0' - 10"
WARNING: ELECTRICAL SHOCK HAZARD
THE DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE UNGROUNDED
AND MAY BE ENERGIZED
Install at each junvtion box, combiner box, disconnect and device where energized,
ungrounded circuits bay be exposed during service
6 6" = 1'-0" Sign Misc. Warning
7 6" = 1'-0" Sign AC Disconnect 3
THIS SERVICE IS FED FROM MULTIPLE
SOURCES: GRID AND PV ARRAY
0' - 6"
0' - 9"
Install on Main Service
0' - 9"
8 6" = 1'-0" Sign Main Service 1
9 12" = 1'-0" Sign AC Disconnect 2
10 12" = 1'-0" Sign Conduit Sticker
11 6" = 1'-0" Sign Main Point of Connection
SOLAR PV
AC DISCONNECT
PHOTOVOLTAIC POWER SOURCE RATINGS
CURRENT AT MAX POWER (A): 37
OPERATING VOLTAGE:
240VAC, 1Φ
0' - 1"
0' - 6"
0' - 1"
Note:
-Reflective material
-Place every 10 feet on all interior and exterior DC conduits, raveways, enclosures,and cable
assemblies, at turns, above and /or below penetrations,all DC combiners, and junction boxes.
0' - 3"
CAUTION: SOLAR ELECTRIC SYSTEM
CONNECTED
Install on Main Service Disconnect
0' - 2"
Sign and Markings Format:
(1) White lettering on red background
(2) Minimum 3/8 - inch letter height
(3) All letters to be capitalized
(4) Arial or similar font, non-bold
(5) Signage - permanent reflective weather resistant material suitable for
the environment
0' - 9"
0' - 2"
WARNING: INVERTER OUTPUT
CONNECTION. DO NOT RELOCATE THIS
OVERCURRENT DEVICE.
Install on Inverter(s) output connection.
0' - 2"
GANGER BOLT, 5/16" X 6" SS
12" X 12" X .050" AL FLASHING
ROOFING MATERIAL
WASHER , SPIT-LOCK, 5/16 X 1", SS
BASE BLOCK, CAST AL
Weight of Materials
Module weight (Suniva): 39.5 lbs
Module area: 17.46 ft²
2X FRAMING
Mounting hardware weight: 5 lbs/module
Post density: 1.0 post per module (minimum)
Maximum point load: (39.5 + 5) / ( 1.0 post)
= 44.5 lbs per attachment mount
Roof load = module weight / module area
= (39.5 + 5) / 17.46 = 2.5 lbs/ft.²
Note:
Roof penetrations will be sealed with OSI PL Polyurethane Roof and Flashing Sealant
Specifications: Meets or exceeds Federal Specifications TT-S-00230C, Type II Class A;
ASTM C-920, Type S, Grade NS, Class 25, use NT, M, and A
30 LB. FELT PAPER (N)
AT ATTACHMENT POINTS
WASHER, FENDER, 5/16"X 6", SS
WASHER , .296"ID X 7/8" OD X 1/8" THICK, EPDM
HEX NUT, 5/16-18, SS
WASHER , SEALING, 5/16"ID X 3/4" OD, SS/EPDM
L-FOOT FOR UNIRACK
(E) 2x8 ROOF RAFTERS
@ 24" O.C.
ROOFING MATERIAL:
COMP. SHINGLE
6"x1.25" STANDOFF
LOC. TYP W/ (2) 5/16" DIA.
X 3-1/2" LAG SCREWS, TYP
SEE DETAIL 3/D101
UNIRAC SOLAR MOUNT
RACKING TYP.
UNISTRUT ATTACHED
TO STAND OFF TYP.
27' - 6 9/32"
16' - 5 25/32"
5
Roof Type: Composition Shingle
Note:
Arrays are supported at a
Maximum of 6 feet.
Panels shall have 3-inch
clearance from the roof
surface to the lowest
edge of panel/ support
framing
5.00°
A
B
D101
1' - 6 3/8"
2' - 0"
5.00°
YOUR LOGO
Your Address
Your Contact Info
Confidentiality Statement:
This drawing is the property of
Your Company. This information is
confidential and is to be used only
in connection with work described
by Shorebreak. No part is to be
discolosed to others without written
permission from Shorebreak.
Your Company
LIC# Your Licence Number
EXP: -/-/-
X_________________________
Project Address.
YOUR PROJECT
NAME
Your Company
Layout & Details
D101
10/7/2014 6:11:39 PM
To scale on 24x36 paper
1 1/8" = 1'-0" Layout
2 1/8" = 1'-0" Enlarged Roof Layout - Array 1
12 12" = 1'-0" Sign AC Disconnect 1 (2" x 3")
Typical Caution Signage per CEC 690
Requirements
13 6" = 1'-0"
5 1 1/2" = 1'-0" Roof Attachement Detail
3 1/8" = 1'-0" Enlarged Roof Layout - Array 2
4 3/16" = 1'-0" Elevations of Solar Array
No. Description Date
4. BRANCH CIRCUIT 1-3
33 MODULES, SUNIVA
OPT260-60-4-1B0, 260WATTS
(2) 10 MODULES PER BRANCH CIRCUIT
(1) 13 MODULES PER BRANCH CIRCUIT
MODULE AMPERAGE:
8.06 IMP, 8.50ISC
MODULE VOLTAGE:
30.8 VMP, 38.1 VOC
33 MICRO INVERTERS, ENPHASE
M215-60-2LL-2X, 215W
33 INVERTERS PER BRANCH CIRCUIT
MICRO INVERTER MAX OUTPUT:
0.9A , 240V
SEE SPECIFICATION SHEET
FOR ELECTRICAL
PARAMETERS AND
WARRANTY INFO
(1EA) AC DISCONNECT
60A, 240VAC, 2P
NEMA 3R
SQUARE DU222RB
VISIBLE / LOCKABLE
USE #8 THWN-2 GEC
M SERVICE
GRD
FROM
UTILITY
(E) GROUND ROD
MAIN PANEL
200A BUS, 240V
OCP 29.7 * 1.25 = 37.14A ~ 40A W/ 40A BACKFED BRKR
V(AC) = 240 1PH 3W
MAX AC OUTPUT CURRENT = 29.7A
(2) #8 THWN - 2
(1) #8 THWN - 2 NEUTRAL
(1) #10 THWN-2 EGC
3/4" CONDUIT (FILL = 0.1309)
(E)
200A
MAIN
MISC.
FACILITY
LOADS
JUNCTION
BOX
40A
ENPHASE ENVOY
COMMUNICATIONS
GATWAY
AC Electrical Calcs.
System AC Wiring Run
Pmax = (235.2 ptc rating)*(33 panels)*(96% inverter eff.) = 7451 Wac
Imax = (7451 Watts) / (240V) = 31 Aac
Idesign = (31 A)*(1.25) =38.8A --> #8 THWN-2
--> 40A C/B
(N) SUB PANEL
100A BUS, 240V
W/ (3) 15A BACKFED BRKR
15A
15A
15A
15A
OCP 11.7*1.25 = 14.6A ~ 15A
V(AC) = 240 1PH 3W
MAX AC OUTPUT CURRENT = 11.7A
(6) #12 THWN - 2
(3) #12 THWN - 2 NEUTRAL
(3) #10 THWN-2 EGC
3/4" CONDUIT (FILL = 0.183)
System AC Wiring Output per Branch (13 Micro Inverters)
Inverter Max output current = (0.9A) * (13 Inverters) = 11.7 Aac
Idesign = (11.7 A)*(1.25) =14.6 A --> #12 THWN-2
--> 15A C/B
Max System AC Wiring Output
Inverter Max output current = (0.9 A) * (33 Inverters) = 29.7 Aac
Idesign = (29.7 A)*(1.25) =37A --> #8 THWN-2
--> 40A C/B
ENPHASE ENGAGE CABLE. INSTALL
END CAP ON THE LAST INVERTER
CABLE OF BRANCH CIRCUIT, TYP.
OCP 11.7*1.25 = 14.6A ~ 15A
V(AC) = 240 1PH 3W
MAX AC OUTPUT CURRENT = 11.7A
(6) #12 THWN - 2
(3) #12 THWN - 2 NEUTRAL
(1) #10 THWN-2 EGC
3/4" CONDUIT (FILL = 0.1408)
OCP 29.7 * 1.25 = 37.14A ~ 40A
V(AC) = 240 1PH 3W
MAX AC OUTPUT CURRENT = 29.7A
(2) #8 THWN - 2
(1) #8 THWN - 2 NEUTRAL
(1) #10 THWN-2 EGC
3/4" CONDUIT (FILL = 0.1309)
WIRELESS SINGNAL
TO ROUTER
System AC Wiring Output per Branch (10 Micro Inverters)
Inverter Max output current = (0.9A) * (10 Inverters) = 9 Aac
Idesign = (9 A)*(1.25) =11.25 A --> #12 THWN-2
--> 15A C/B
10-24 SS NUT
10-24 SS LOCK WASHER
10-24 SS FLAT WASHER
10-24 SS BOLT
TORQUE
TO 18 FT-LBS
RAIL FRAME
ILSCO #4 LAY
IN LUG TINNED
YOUR LOGO
Your Address
Your Contact Info
Confidentiality Statement:
This drawing is the property of
Your Company. This information is
confidential and is to be used only
in connection with work described
by Shorebreak. No part is to be
discolosed to others without written
permission from Shorebreak.
Your Company
LIC# Your Licence Number
EXP: -/-/-
X_________________________
Project Address.
YOUR PROJECT
NAME
Your Company
Elect'l Diagrams
E101
10/7/2014 6:11:43 PM
To scale on 24x36 paper
1 12" = 1'-0" Line Diagram
3 6" = 1'-0" Detail Conduit Body Grounding
4 6" = 1'-0" Detail Lay-in Lug Grounding
2 12" = 1'-0" Wiring Chart
No. Description Date
5. YOUR LOGO
Your Address
Your Contact Info
Confidentiality Statement:
This drawing is the property of
Your Company. This information is
confidential and is to be used only
in connection with work described
by Shorebreak. No part is to be
discolosed to others without written
permission from Shorebreak.
Your Company
LIC# Your Licence Number
EXP: -/-/-
X_________________________
Project Address.
YOUR PROJECT
NAME
Your Company
Spec Sheets
E102
10/7/2014 6:11:49 PM
To scale on 24x36 paper
3 12" = 1'-0" Spec Sheet L Foot Attachment
4 12" = 1'-0" Spec Sheet Sun Frame Details
1 12" = 1'-0" Spec Sheet Enphase Micro Inverters
5 12" = 1'-0" Spec Sheet Quick Mount PV
2 12" = 1'-0" Spec Sheet Suniva Solar Module
No. Description Date