Switch Fabric- Troubleshooting tips
How to Troubleshoot Switch Fabric?
Introduction
What is Switch Fabric?
The switch fabric is essentially the backplane for all ports and modules on the switch
module. When a connection is made from a port on one module to a port on another
module, it is made across the switch fabric. Physically, it is the combination of silicon,
plastic, and metal that enables ports to connect and pass traffic between themselves.
The switch fabric can be blocking or non-blocking. Non-blocking fabric ensures that the
total bandwidth of all ports that use the switch fabric do not exceed its capacity. What this
means is that the density of the ports on the switch are such that their total capacity will
never be greater than that of the switch fabric. Switches operating in non-blocking mode
ensure that congestion will never occur on the switch, nor will ports ever want for
bandwidth between each other.
A blocking switch has a port density capacity that exceeds the total capacity of the switch
fabric. Control is possible by blocking traffic flow when the switch fabric capacity is
exceeded or otherwise not available.
The switch fabric resides on the SE. When a port has to communicate with another port,
it has the supervisor check its tables (Content Addressable Memory [CAM] for Layer 2
addresses and Ternary CAM [TCAM] for Layer 3 addresses) to determine what slot and
port it needs. The supervisor then establishes the connection between the ports.The
switch fabric can also reside on its own module (such as the Switch Fabric Module 2
(WS-X6500-SFM2) and the Switch Fabric Module (WS-C6500-SFM for the Catalyst 6500
Series), which enables the available capacity to be expanded without replacing the SE,
or to expand beyond the capacity of the SE.
On Catalyst 6500, Switch fabric is a daughter card installed at Sup720 , it used to be a
separate module, Switch Fabric module in its first implementation back in the days of
Sup2. It is used to provide backplane connectivity between linecards. The default
bandwidth available on the backplane of 6500 is 32 Gbps. This 32 Gbps is used by all
1
slots for serial transmission of data. Therefore at any instant only two ports can be
communicating.
With the addition of Switch fabric, the switch’s backplane changes from serially-accessed
bus to crossbar fabric. By using crossbar fabric, many ports can be simultaneously
transmitting and receiving data, providing a much higher throughput.
The crossbar fabric consists of 18 fabric channels, providing each linecard two fabric
channels into the crossbar fabric. These channels can run at 8Gbps or 20Gbps
depending upon the line card used. The CEF256 and dCEF256 series modules connect
to fabric using 8 Gbps per channel and CEF720 series modules connect to it using 20
Gbps per channel.
Requirements
For a module to use switch fabric, it should be a fabric enabled module
Troubleshooting Tips
1. If the Fabric Switch Module does not work as expected, check the following:
2
a) Check if the Fabric Switch Status is Active. To do this, use the show fabric active
command. This command will display the current status of the Fabric Switch. Here is an
example.
Switch# show fabric active
Active fabric card in slot 5
No backup fabric card in the system
If the system has backup fabric card, then:
Switch #show fabric active
show fabric active:
Active fabric card in slot 5
Backup fabric card in slot 6
b) Check the fabric status of switching modules in the device. To do this use the show
fabric status [slot_number | all] command. This command will display the fabric status
of one or all switching modules. Here is an example,
Switch# show fabric status
slot channel speed module fabric
status status
1 0 8G OK OK
5 0 8G OK Up- Timeout
6 0 20G OK Up- BufError
8 0 8G OK OK
8 1 8G OK OK
9 0 8G Down- DDRsync OK
Switch#
3
c) Check the fabric utilization of switching modules. To do this use the show fabric
utilization [slot_number | all] command. This command will display the fabric utilization
of one or all modules.
Here is an example,
Switch# show fabric utilization all
slot channel speed Ingress % Egress %
1 0 20G 0 0
1 1 20G 0 0
2 0 20G 0 24
2 1 20G 0 24
3 0 20G 48 0
4 0 20G 0 0
4 1 20G 0 0
2. In certain rare condi tions out put of 'show fabric channel-counters' may show
incrementing number of rxErrors.
Switch#show fabric channel-counters
Slot channel rxErrors txErrors txDrops lbusDrops
1 1 0 0 0 0
3 0 0 0 0 0
3 1 0 0 0 0
4
5 0 5 0 0 0
8 0 39 0 0 0
8 1 0 0 0 0
a) RxRrror indicates that the module received corrupted packet(s) and dropped.
b) The Fabric do NOT check CRC when forwarding frames between different fabric
ports/channels.
c) This could be due to the receiving module corrupting the frames or receiving
corrupted frames from any fabric-enabled module in the switch.
The following actions can be taken to solve these errors:
a) Reseat the module with rxErrors. Reloading the linecard in question might stop the
errors for some time, but the errors might eventually come back.
b) If empty slot is available in the chassis move the affected line card to empty slot.
c) If no empty slots available, swap the linecard that counts rxErrors with other linecard
within the chassis (with no issue) or good known working linecard.
d) Swap the active and standby supervisors (i.e. move supervisor from slot 5 to slot 6
and vice versa. Sup failover.
e) Replace the affected linecard.
If the output of "show fabric status" command is showing "not-hot" for linecards under
hotStandby support.
Switch#show fabric status
slot channel speed module fabric hotStandby Standby Standby
status status support module fabric
3 0 20G OK OK Y(not-hot)
5
3 1 20G OK OK Y(not-hot)
4 0 20G OK OK Y(not-hot)
4 1 20G OK OK Y(not-hot)
5 0 20G OK OK N/A
5 1 20G OK OK N/A
6 0 20G OK OK N/A
6 1 20G OK OK N/A
7 0 20G OK OK Y(not-hot)
7 1 20G OK OK Y(not-hot)
8 0 20G OK OK Y(not-hot)
8 1 20G OK OK Y(not-hot)
9 0 20G OK OK Y(not-hot)
9 1 20G OK OK Y(not-hot)
Reason: The standby fabric hot sync feature is only supported on the E version of the
6500 chassis, and this system has a non-E version.
3. If you see the error message as, “SP: Linecard endpoint of Channel 7 lost
Sync.
To Lower fabric and trying to recover now!”.
Reason: The message caused by a line card not being fully or properly seated. To
identify this line card - the capture of show fabric fpoe map command need to be
analyzed. Here is an example, 同上
6
Switch#show fabric fpoe map
slot channel fpoe
1 0 0
1 1 9
2 0 1
2 1 10
3 0 2
3 1 11
4 0 3
4 1 12
5 0 4
6 0 5
6 1 14
7 0 6
7 1 15
8 0 7
8 1 16
9 0 8
9 1 17
Workaround: The fpoe will be mapped to a specific line card slot. Once the suspect line
card is identified From the output of show fabric fpoe map, fpoe 7 points to the line
7
card in slot 8 and that is card that is causing the error messages.your next action
should be to schedule a removal and re-insert of that card to try to eliminate this
message from re-occurring.
4. If the system switching performance drops from 30Mpps to 15Mpps.
Reason: When classic and fabric enabled modules are mixed in a chassis, the system
switching performance drops from 30Mpps to 15Mpps.
Older "Classic" modules in the 6500, models 61xx, 62xx, 63xx, 64xx, send all traffic over
the switch BUS backplane, to be forwarded by the supervisor. Fabric enabled modules
only send the packet headers over the bus and the switch fabric can be utilized for
forwarding the data portion of the packet.
Workaround: Consider replacing any "Classic" modules with fabric enabled modules, in
order to increase system performance.
5. To troubleshoot further, collect the following show command output before
opening a TAC case.
step 1. turn on service internal.
switch# configure terminal
switch(config)# service internal
step 2. collect the requested logs.
terminal length 0
show fabric active
show fabric channel-counters
show fabric drop
show fabric errors
show fabric errors threshold
8
show fabric fpoe map
show fabric status
show fabric utilization
show tech-support
remote login switch
terminal length 0
show fabric error
show fabric state-machine channel state
show fabric state-machine channel event_trace 11
show fabric resync
show fabric timeout
show platform hardware capacity fabric
exit
step 3. turn off service internal
switch # configure terminal
switch(config)# no service internal
9
Troubleshooting Example
1. Fabric Time out Error Message:
%FABRIC-SP-[module-number]-TIMEOUT_ERR: Fabric in slot [dec] reported timeout
error for channel [dec] (Module [dec], fabric connection [dec])
Description
The error message indicates that firmware code on the fabric detected that the input or
output buffer was not moving. To recover from this condition, the system will
automatically
resynchronize the fabric channel.
Troubleshooting Steps
1. Issue the command “hw-module reset” to soft-reset the module. After the module
is up again,
2. capture the output of the command “show module” and the command “show
diagnostic module all”.
Sample Output Of “show module”
Show Module
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ --------- ------------------------------------
2 24 CEF720 24 port 1000mb SFP WS-X6724-SFP SAL0AAAAAAA
3 24 CEF720 24 port 1000mb SFP WS-X6724-SFP SAD0AAAAAAA
5 2 Supervisor Engine 720 (Hot) WS-SUP720-3B SAD0AAAAAAA
6 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAD0AAAAAAA
10
7 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL1AAAAAAA
8 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL1AAAAAAA
Sample Output of “show diagnostic module all”
Switch#show diagnostic module all
Current bootup diagnostic level: minimal
Module 6: Supervisor Engine 720 (Active)
Overall Diagnostic Result for Module 6 : PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) TestScratchRegister -------------> .
2) TestSPRPInbandPing --------------> .
3) TestTransceiverIntegrity:
Port 1 2
----------
U U
4) TestActiveToStandbyLoopback:
Port 1 2
----------
U U
5) TestLoopback:
11
Port 1 2
---------
6) TestNewIndexLearn ---------------> .
7) TestDontConditionalLearn --------> .
8) TestBadBpduTrap -----------------> .
9) TestMatchCapture ----------------> .
10) TestProtocolMatchChannel --------> .
11) TestFibDevices ------------------> .
12) TestIPv4FibShortcut -------------> .
13) TestL3Capture2 ------------------> .
14) TestIPv6FibShortcut -------------> .
15) TestMPLSFibShortcut -------------> .
16) TestNATFibShortcut --------------> .
17) TestAclPermit -------------------> .
18) TestAclDeny ---------------------> .
19) TestQoSTcam ---------------------> .
20) TestL3VlanMet -------------------> .
21) TestIngressSpan -----------------> .
22) TestEgressSpan ------------------> .
23) TestNetflowInlineRewrite:
Port 1 2
12
----------
U U
24) TestFabricSnakeForward ----------> .
25) TestFabricSnakeBackward ---------> .
26) TestTrafficStress ---------------> U
27) TestFibTcamSSRAM ----------------> U
28) TestAsicMemory ------------------> U
29) TestAclQosTcam ------------------> U
30) TestNetflowTcam -----------------> U
31) ScheduleSwitchover --------------> U
32) TestFirmwareDiagStatus ----------> .
In case the output doesn’t come as expected, physically pull out and reseat the module
firmly in the chassis to hard-reset the module. After the module is up again, capture the
output of the command “show module” and “show diagnostic module all”
Here is an example of failed diagnostic test for module 1
Module 1: Catalyst 6000 supervisor 2 (Active) SerialNo :
Overall Diagnostic Result for Module 1 : MINOR ERROR
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) TestSPRPInbandPing --------------> F
2) TestTransceiverIntegrity:
13
2. Overruns on some ports on Card 5 (WS-X6548-GE-TX)
Switch1# show interface counters
Noticed "overruns" on 4 interfaces. They were not incrementing
GigabitEthernet5/1 is up, line protocol is up (connected)
Full-duplex, 1000Mb/s, media type is 10/100/1000BaseT
0 input errors, 0 CRC, 0 frame, 26 overrun, 0 ignored
GigabitEthernet5/6 is up, line protocol is up (connected)
Full-duplex, 1000Mb/s, media type is 10/100/1000BaseT
0 input errors, 0 CRC, 0 frame, 14 overrun, 0 ignored
GigabitEthernet5/9 is up, line protocol is up (connected)
Full-duplex, 1000Mb/s, media type is 10/100/1000BaseT
0 input errors, 0 CRC, 0 frame, 159 overrun, 0 ignored
GigabitEthernet5/12 is up, line protocol is up (connected)
Full-duplex, 1000Mb/s, media type is 10/100/1000BaseT
0 input errors, 0 CRC, 0 frame, 269 overrun, 0 ignored
Also will enabling switch fabric rectify the overruns?
Solution:
Enabling switch fabric will not rectify overruns because after the installation of a Switch
Fabric Module in a Cisco Catalyst 6500 series switch, the traffic is forwarded to and from
modules in different modes which doesn't necessarily facilitate resolution for overruns.
The traffic is forwarded in one of these of these modes:
14
a) Flow-through mode: In this mode, data passes between the local bus and the
supervisor engine bus. This mode is used for traffic to or from modules that are not
fabric-enabled.
b) Truncated mode: Only truncated data (the first 64 bytes of the frame) goes over the
switch fabric channel if both the destination and the source are fabric-enabled modules. If
either the source or destination is not a fabric-enabled module, the data goes through the
switch fabric channel and the data bus. The Switch Fabric Module does not get involved
when traffic is forwarded between modules that are not fabric-enabled.
c) Compact mode: A compact version of the DBus header is forwarded over the switch
fabric channel, which delivers the best possible switching rate. Modules that are not
fabric-enabled do not support the compact mode and generate cyclic redundancy check
(CRC) errors upon receipt of frames in compact mode. This mode is used only when no
such modules are installed in the chassis.
Let’s understand what overrun is:-
Overrun - The number of times the receiver hardware was unable to hand received data
to a hardware buffer
Common Cause - The input rate of traffic exceeded the ability of the receiver to handle
the data.
From the given example, the module used is WS-X6548-GE-TX:
This module is 8:1 oversubscribed. The ports on this module go to servers. On these
modules there is a single 1-Gigabit Ethernet uplink from the port ASIC that supports eight
ports. These cards share a 1 Mb buffer between a group of ports (1-8, 9-16, 17-24, 25-
32, 33-40, and 41-48) since each block of eight ports is 8:1 oversubscribed. The
aggregate throughput of each block of eight ports cannot exceed 1 Gbps. These line
cards are oversubscription cards that are designed to extend gigabit to the desktop and
might not be ideal for server farm connectivity. For more information refer to:-
Troubleshooting Switch Port and Interface Problems
To resolve this issue of overrun, move the high volume servers to ports on different asic
groups, so that the traffic flow through the 8 ports of every asic group does not exceed 1
Gbps. Alternatively look for other ideal design recommendations on line cards that have
better oversubscription ratio.
It refers from: https://supportforums.cisco.com/document/71201/switch-fabric-
troubleshooting-tips
15
More related:
The Differences of XFP, SFP and SFP+
How to Identify the Genuine Cisco SFP?
Basic Knowledge on Cisco SFP Modules
Technical Specifications for Cisco SFP Modules
More Cisco products and Reviews you can visit: http://www.3anetwork.com/blog
3Anetwork.com is a world leading Cisco networking products supplier, we supply original
new Cisco networking equipments, including Cisco Catalyst switches, Cisco routers,
Cisco firewalls, Cisco wireless products, Cisco modules and interface cards products at
competitive price and ship to worldwide.
Our website: http://www.3anetwork.com
Telephone: +852-3069-7733
Email: info@3Anetwork.com
Address: 23/F Lucky Plaza, 315-321 Lockhart Road, Wanchai, Hongkong
16

More Related Content

Similar to How to troubleshoot switch fabric

Testing tool for an automated ticketing system
Testing tool for an automated ticketing systemTesting tool for an automated ticketing system
Testing tool for an automated ticketing systemVladimirZitoli
 
Cisco data center support
Cisco data center supportCisco data center support
Cisco data center supportKrunal Shah
 
MX Fabric troubleshootingv1.0.pptx
MX Fabric troubleshootingv1.0.pptxMX Fabric troubleshootingv1.0.pptx
MX Fabric troubleshootingv1.0.pptxVimalMallick
 
NetSim Technology Library- Military radio-tdma-and-dtdma
NetSim Technology Library- Military radio-tdma-and-dtdmaNetSim Technology Library- Military radio-tdma-and-dtdma
NetSim Technology Library- Military radio-tdma-and-dtdmaVishal Sharma
 
Differential pair routing_pcb-oct2011
Differential pair routing_pcb-oct2011Differential pair routing_pcb-oct2011
Differential pair routing_pcb-oct2011Muhammad Saad
 
weblogic perfomence tuning
weblogic perfomence tuningweblogic perfomence tuning
weblogic perfomence tuningprathap kumar
 
FEATool Multiphysics Matlab FEM and CFD Toolbox - v1.6 Quickstart Guide
FEATool Multiphysics Matlab FEM and CFD Toolbox - v1.6 Quickstart GuideFEATool Multiphysics Matlab FEM and CFD Toolbox - v1.6 Quickstart Guide
FEATool Multiphysics Matlab FEM and CFD Toolbox - v1.6 Quickstart GuideFEATool Multiphysics
 
Advanced Comuter Architecture Ch6 Problem Solutions
Advanced Comuter Architecture Ch6 Problem SolutionsAdvanced Comuter Architecture Ch6 Problem Solutions
Advanced Comuter Architecture Ch6 Problem SolutionsJoe Christensen
 
systemverilog-interview-questions.docx
systemverilog-interview-questions.docxsystemverilog-interview-questions.docx
systemverilog-interview-questions.docxssuser1c8ca21
 
eRAN8.1 Radio & Performance-Interference Handling-CAMC feature introduction.ppt
eRAN8.1 Radio & Performance-Interference Handling-CAMC feature introduction.ppteRAN8.1 Radio & Performance-Interference Handling-CAMC feature introduction.ppt
eRAN8.1 Radio & Performance-Interference Handling-CAMC feature introduction.pptAhmed963381
 
Hướng dẫn cài đặt switch planet layer 3
Hướng dẫn cài đặt switch planet layer 3Hướng dẫn cài đặt switch planet layer 3
Hướng dẫn cài đặt switch planet layer 33c telecom
 
Configuring the communication on FlexRay: the case of the static segment
Configuring the communication on FlexRay: the case of the static segmentConfiguring the communication on FlexRay: the case of the static segment
Configuring the communication on FlexRay: the case of the static segmentNicolas Navet
 
Advantages of 64 Bit 5T SRAM
Advantages of 64 Bit 5T SRAMAdvantages of 64 Bit 5T SRAM
Advantages of 64 Bit 5T SRAMIJSRED
 
Advantages of 64 Bit 5T SRAM
Advantages of 64 Bit 5T SRAMAdvantages of 64 Bit 5T SRAM
Advantages of 64 Bit 5T SRAMIJSRED
 
IRJET- Metastability Mitigation & Error Masking of High Speed Flip-Flop
IRJET- Metastability Mitigation & Error Masking of High Speed Flip-FlopIRJET- Metastability Mitigation & Error Masking of High Speed Flip-Flop
IRJET- Metastability Mitigation & Error Masking of High Speed Flip-FlopIRJET Journal
 

Similar to How to troubleshoot switch fabric (20)

Testing tool for an automated ticketing system
Testing tool for an automated ticketing systemTesting tool for an automated ticketing system
Testing tool for an automated ticketing system
 
lecciones ccna3
lecciones ccna3lecciones ccna3
lecciones ccna3
 
A018120105
A018120105A018120105
A018120105
 
Cisco data center support
Cisco data center supportCisco data center support
Cisco data center support
 
MX Fabric troubleshootingv1.0.pptx
MX Fabric troubleshootingv1.0.pptxMX Fabric troubleshootingv1.0.pptx
MX Fabric troubleshootingv1.0.pptx
 
NetSim Technology Library- Military radio-tdma-and-dtdma
NetSim Technology Library- Military radio-tdma-and-dtdmaNetSim Technology Library- Military radio-tdma-and-dtdma
NetSim Technology Library- Military radio-tdma-and-dtdma
 
Differential pair routing_pcb-oct2011
Differential pair routing_pcb-oct2011Differential pair routing_pcb-oct2011
Differential pair routing_pcb-oct2011
 
weblogic perfomence tuning
weblogic perfomence tuningweblogic perfomence tuning
weblogic perfomence tuning
 
FEATool Multiphysics Matlab FEM and CFD Toolbox - v1.6 Quickstart Guide
FEATool Multiphysics Matlab FEM and CFD Toolbox - v1.6 Quickstart GuideFEATool Multiphysics Matlab FEM and CFD Toolbox - v1.6 Quickstart Guide
FEATool Multiphysics Matlab FEM and CFD Toolbox - v1.6 Quickstart Guide
 
Advanced Comuter Architecture Ch6 Problem Solutions
Advanced Comuter Architecture Ch6 Problem SolutionsAdvanced Comuter Architecture Ch6 Problem Solutions
Advanced Comuter Architecture Ch6 Problem Solutions
 
Kai hwang solution
Kai hwang solutionKai hwang solution
Kai hwang solution
 
systemverilog-interview-questions.docx
systemverilog-interview-questions.docxsystemverilog-interview-questions.docx
systemverilog-interview-questions.docx
 
eRAN8.1 Radio & Performance-Interference Handling-CAMC feature introduction.ppt
eRAN8.1 Radio & Performance-Interference Handling-CAMC feature introduction.ppteRAN8.1 Radio & Performance-Interference Handling-CAMC feature introduction.ppt
eRAN8.1 Radio & Performance-Interference Handling-CAMC feature introduction.ppt
 
Hướng dẫn cài đặt switch planet layer 3
Hướng dẫn cài đặt switch planet layer 3Hướng dẫn cài đặt switch planet layer 3
Hướng dẫn cài đặt switch planet layer 3
 
C1031118
C1031118C1031118
C1031118
 
Configuring the communication on FlexRay: the case of the static segment
Configuring the communication on FlexRay: the case of the static segmentConfiguring the communication on FlexRay: the case of the static segment
Configuring the communication on FlexRay: the case of the static segment
 
Exam viewer2
Exam viewer2Exam viewer2
Exam viewer2
 
Advantages of 64 Bit 5T SRAM
Advantages of 64 Bit 5T SRAMAdvantages of 64 Bit 5T SRAM
Advantages of 64 Bit 5T SRAM
 
Advantages of 64 Bit 5T SRAM
Advantages of 64 Bit 5T SRAMAdvantages of 64 Bit 5T SRAM
Advantages of 64 Bit 5T SRAM
 
IRJET- Metastability Mitigation & Error Masking of High Speed Flip-Flop
IRJET- Metastability Mitigation & Error Masking of High Speed Flip-FlopIRJET- Metastability Mitigation & Error Masking of High Speed Flip-Flop
IRJET- Metastability Mitigation & Error Masking of High Speed Flip-Flop
 

Recently uploaded

08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking MenDelhi Call girls
 
Benefits Of Flutter Compared To Other Frameworks
Benefits Of Flutter Compared To Other FrameworksBenefits Of Flutter Compared To Other Frameworks
Benefits Of Flutter Compared To Other FrameworksSoftradix Technologies
 
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptxMaking_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptxnull - The Open Security Community
 
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 3652toLead Limited
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking MenDelhi Call girls
 
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...shyamraj55
 
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Alan Dix
 
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphSIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphNeo4j
 
Snow Chain-Integrated Tire for a Safe Drive on Winter Roads
Snow Chain-Integrated Tire for a Safe Drive on Winter RoadsSnow Chain-Integrated Tire for a Safe Drive on Winter Roads
Snow Chain-Integrated Tire for a Safe Drive on Winter RoadsHyundai Motor Group
 
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Patryk Bandurski
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024Scott Keck-Warren
 
How to Remove Document Management Hurdles with X-Docs?
How to Remove Document Management Hurdles with X-Docs?How to Remove Document Management Hurdles with X-Docs?
How to Remove Document Management Hurdles with X-Docs?XfilesPro
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking MenDelhi Call girls
 
Azure Monitor & Application Insight to monitor Infrastructure & Application
Azure Monitor & Application Insight to monitor Infrastructure & ApplicationAzure Monitor & Application Insight to monitor Infrastructure & Application
Azure Monitor & Application Insight to monitor Infrastructure & ApplicationAndikSusilo4
 
CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):comworks
 
Hyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your Budget
Hyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your BudgetHyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your Budget
Hyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your BudgetEnjoy Anytime
 
Key Features Of Token Development (1).pptx
Key  Features Of Token  Development (1).pptxKey  Features Of Token  Development (1).pptx
Key Features Of Token Development (1).pptxLBM Solutions
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitecturePixlogix Infotech
 

Recently uploaded (20)

08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
 
Benefits Of Flutter Compared To Other Frameworks
Benefits Of Flutter Compared To Other FrameworksBenefits Of Flutter Compared To Other Frameworks
Benefits Of Flutter Compared To Other Frameworks
 
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptxMaking_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
 
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
 
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
Automating Business Process via MuleSoft Composer | Bangalore MuleSoft Meetup...
 
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
 
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphSIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
 
Snow Chain-Integrated Tire for a Safe Drive on Winter Roads
Snow Chain-Integrated Tire for a Safe Drive on Winter RoadsSnow Chain-Integrated Tire for a Safe Drive on Winter Roads
Snow Chain-Integrated Tire for a Safe Drive on Winter Roads
 
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024
 
How to Remove Document Management Hurdles with X-Docs?
How to Remove Document Management Hurdles with X-Docs?How to Remove Document Management Hurdles with X-Docs?
How to Remove Document Management Hurdles with X-Docs?
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men
 
Azure Monitor & Application Insight to monitor Infrastructure & Application
Azure Monitor & Application Insight to monitor Infrastructure & ApplicationAzure Monitor & Application Insight to monitor Infrastructure & Application
Azure Monitor & Application Insight to monitor Infrastructure & Application
 
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptxE-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
 
CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):
 
Hyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your Budget
Hyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your BudgetHyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your Budget
Hyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your Budget
 
Key Features Of Token Development (1).pptx
Key  Features Of Token  Development (1).pptxKey  Features Of Token  Development (1).pptx
Key Features Of Token Development (1).pptx
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC Architecture
 

How to troubleshoot switch fabric

  • 1. Switch Fabric- Troubleshooting tips How to Troubleshoot Switch Fabric? Introduction What is Switch Fabric? The switch fabric is essentially the backplane for all ports and modules on the switch module. When a connection is made from a port on one module to a port on another module, it is made across the switch fabric. Physically, it is the combination of silicon, plastic, and metal that enables ports to connect and pass traffic between themselves. The switch fabric can be blocking or non-blocking. Non-blocking fabric ensures that the total bandwidth of all ports that use the switch fabric do not exceed its capacity. What this means is that the density of the ports on the switch are such that their total capacity will never be greater than that of the switch fabric. Switches operating in non-blocking mode ensure that congestion will never occur on the switch, nor will ports ever want for bandwidth between each other. A blocking switch has a port density capacity that exceeds the total capacity of the switch fabric. Control is possible by blocking traffic flow when the switch fabric capacity is exceeded or otherwise not available. The switch fabric resides on the SE. When a port has to communicate with another port, it has the supervisor check its tables (Content Addressable Memory [CAM] for Layer 2 addresses and Ternary CAM [TCAM] for Layer 3 addresses) to determine what slot and port it needs. The supervisor then establishes the connection between the ports.The switch fabric can also reside on its own module (such as the Switch Fabric Module 2 (WS-X6500-SFM2) and the Switch Fabric Module (WS-C6500-SFM for the Catalyst 6500 Series), which enables the available capacity to be expanded without replacing the SE, or to expand beyond the capacity of the SE. On Catalyst 6500, Switch fabric is a daughter card installed at Sup720 , it used to be a separate module, Switch Fabric module in its first implementation back in the days of Sup2. It is used to provide backplane connectivity between linecards. The default bandwidth available on the backplane of 6500 is 32 Gbps. This 32 Gbps is used by all 1
  • 2. slots for serial transmission of data. Therefore at any instant only two ports can be communicating. With the addition of Switch fabric, the switch’s backplane changes from serially-accessed bus to crossbar fabric. By using crossbar fabric, many ports can be simultaneously transmitting and receiving data, providing a much higher throughput. The crossbar fabric consists of 18 fabric channels, providing each linecard two fabric channels into the crossbar fabric. These channels can run at 8Gbps or 20Gbps depending upon the line card used. The CEF256 and dCEF256 series modules connect to fabric using 8 Gbps per channel and CEF720 series modules connect to it using 20 Gbps per channel. Requirements For a module to use switch fabric, it should be a fabric enabled module Troubleshooting Tips 1. If the Fabric Switch Module does not work as expected, check the following: 2
  • 3. a) Check if the Fabric Switch Status is Active. To do this, use the show fabric active command. This command will display the current status of the Fabric Switch. Here is an example. Switch# show fabric active Active fabric card in slot 5 No backup fabric card in the system If the system has backup fabric card, then: Switch #show fabric active show fabric active: Active fabric card in slot 5 Backup fabric card in slot 6 b) Check the fabric status of switching modules in the device. To do this use the show fabric status [slot_number | all] command. This command will display the fabric status of one or all switching modules. Here is an example, Switch# show fabric status slot channel speed module fabric status status 1 0 8G OK OK 5 0 8G OK Up- Timeout 6 0 20G OK Up- BufError 8 0 8G OK OK 8 1 8G OK OK 9 0 8G Down- DDRsync OK Switch# 3
  • 4. c) Check the fabric utilization of switching modules. To do this use the show fabric utilization [slot_number | all] command. This command will display the fabric utilization of one or all modules. Here is an example, Switch# show fabric utilization all slot channel speed Ingress % Egress % 1 0 20G 0 0 1 1 20G 0 0 2 0 20G 0 24 2 1 20G 0 24 3 0 20G 48 0 4 0 20G 0 0 4 1 20G 0 0 2. In certain rare condi tions out put of 'show fabric channel-counters' may show incrementing number of rxErrors. Switch#show fabric channel-counters Slot channel rxErrors txErrors txDrops lbusDrops 1 1 0 0 0 0 3 0 0 0 0 0 3 1 0 0 0 0 4
  • 5. 5 0 5 0 0 0 8 0 39 0 0 0 8 1 0 0 0 0 a) RxRrror indicates that the module received corrupted packet(s) and dropped. b) The Fabric do NOT check CRC when forwarding frames between different fabric ports/channels. c) This could be due to the receiving module corrupting the frames or receiving corrupted frames from any fabric-enabled module in the switch. The following actions can be taken to solve these errors: a) Reseat the module with rxErrors. Reloading the linecard in question might stop the errors for some time, but the errors might eventually come back. b) If empty slot is available in the chassis move the affected line card to empty slot. c) If no empty slots available, swap the linecard that counts rxErrors with other linecard within the chassis (with no issue) or good known working linecard. d) Swap the active and standby supervisors (i.e. move supervisor from slot 5 to slot 6 and vice versa. Sup failover. e) Replace the affected linecard. If the output of "show fabric status" command is showing "not-hot" for linecards under hotStandby support. Switch#show fabric status slot channel speed module fabric hotStandby Standby Standby status status support module fabric 3 0 20G OK OK Y(not-hot) 5
  • 6. 3 1 20G OK OK Y(not-hot) 4 0 20G OK OK Y(not-hot) 4 1 20G OK OK Y(not-hot) 5 0 20G OK OK N/A 5 1 20G OK OK N/A 6 0 20G OK OK N/A 6 1 20G OK OK N/A 7 0 20G OK OK Y(not-hot) 7 1 20G OK OK Y(not-hot) 8 0 20G OK OK Y(not-hot) 8 1 20G OK OK Y(not-hot) 9 0 20G OK OK Y(not-hot) 9 1 20G OK OK Y(not-hot) Reason: The standby fabric hot sync feature is only supported on the E version of the 6500 chassis, and this system has a non-E version. 3. If you see the error message as, “SP: Linecard endpoint of Channel 7 lost Sync. To Lower fabric and trying to recover now!”. Reason: The message caused by a line card not being fully or properly seated. To identify this line card - the capture of show fabric fpoe map command need to be analyzed. Here is an example, 同上 6
  • 7. Switch#show fabric fpoe map slot channel fpoe 1 0 0 1 1 9 2 0 1 2 1 10 3 0 2 3 1 11 4 0 3 4 1 12 5 0 4 6 0 5 6 1 14 7 0 6 7 1 15 8 0 7 8 1 16 9 0 8 9 1 17 Workaround: The fpoe will be mapped to a specific line card slot. Once the suspect line card is identified From the output of show fabric fpoe map, fpoe 7 points to the line 7
  • 8. card in slot 8 and that is card that is causing the error messages.your next action should be to schedule a removal and re-insert of that card to try to eliminate this message from re-occurring. 4. If the system switching performance drops from 30Mpps to 15Mpps. Reason: When classic and fabric enabled modules are mixed in a chassis, the system switching performance drops from 30Mpps to 15Mpps. Older "Classic" modules in the 6500, models 61xx, 62xx, 63xx, 64xx, send all traffic over the switch BUS backplane, to be forwarded by the supervisor. Fabric enabled modules only send the packet headers over the bus and the switch fabric can be utilized for forwarding the data portion of the packet. Workaround: Consider replacing any "Classic" modules with fabric enabled modules, in order to increase system performance. 5. To troubleshoot further, collect the following show command output before opening a TAC case. step 1. turn on service internal. switch# configure terminal switch(config)# service internal step 2. collect the requested logs. terminal length 0 show fabric active show fabric channel-counters show fabric drop show fabric errors show fabric errors threshold 8
  • 9. show fabric fpoe map show fabric status show fabric utilization show tech-support remote login switch terminal length 0 show fabric error show fabric state-machine channel state show fabric state-machine channel event_trace 11 show fabric resync show fabric timeout show platform hardware capacity fabric exit step 3. turn off service internal switch # configure terminal switch(config)# no service internal 9
  • 10. Troubleshooting Example 1. Fabric Time out Error Message: %FABRIC-SP-[module-number]-TIMEOUT_ERR: Fabric in slot [dec] reported timeout error for channel [dec] (Module [dec], fabric connection [dec]) Description The error message indicates that firmware code on the fabric detected that the input or output buffer was not moving. To recover from this condition, the system will automatically resynchronize the fabric channel. Troubleshooting Steps 1. Issue the command “hw-module reset” to soft-reset the module. After the module is up again, 2. capture the output of the command “show module” and the command “show diagnostic module all”. Sample Output Of “show module” Show Module Mod Ports Card Type Model Serial No. --- ----- -------------------------------------- ------------------ --------- ------------------------------------ 2 24 CEF720 24 port 1000mb SFP WS-X6724-SFP SAL0AAAAAAA 3 24 CEF720 24 port 1000mb SFP WS-X6724-SFP SAD0AAAAAAA 5 2 Supervisor Engine 720 (Hot) WS-SUP720-3B SAD0AAAAAAA 6 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAD0AAAAAAA 10
  • 11. 7 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL1AAAAAAA 8 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL1AAAAAAA Sample Output of “show diagnostic module all” Switch#show diagnostic module all Current bootup diagnostic level: minimal Module 6: Supervisor Engine 720 (Active) Overall Diagnostic Result for Module 6 : PASS Diagnostic level at card bootup: minimal Test results: (. = Pass, F = Fail, U = Untested) 1) TestScratchRegister -------------> . 2) TestSPRPInbandPing --------------> . 3) TestTransceiverIntegrity: Port 1 2 ---------- U U 4) TestActiveToStandbyLoopback: Port 1 2 ---------- U U 5) TestLoopback: 11
  • 12. Port 1 2 --------- 6) TestNewIndexLearn ---------------> . 7) TestDontConditionalLearn --------> . 8) TestBadBpduTrap -----------------> . 9) TestMatchCapture ----------------> . 10) TestProtocolMatchChannel --------> . 11) TestFibDevices ------------------> . 12) TestIPv4FibShortcut -------------> . 13) TestL3Capture2 ------------------> . 14) TestIPv6FibShortcut -------------> . 15) TestMPLSFibShortcut -------------> . 16) TestNATFibShortcut --------------> . 17) TestAclPermit -------------------> . 18) TestAclDeny ---------------------> . 19) TestQoSTcam ---------------------> . 20) TestL3VlanMet -------------------> . 21) TestIngressSpan -----------------> . 22) TestEgressSpan ------------------> . 23) TestNetflowInlineRewrite: Port 1 2 12
  • 13. ---------- U U 24) TestFabricSnakeForward ----------> . 25) TestFabricSnakeBackward ---------> . 26) TestTrafficStress ---------------> U 27) TestFibTcamSSRAM ----------------> U 28) TestAsicMemory ------------------> U 29) TestAclQosTcam ------------------> U 30) TestNetflowTcam -----------------> U 31) ScheduleSwitchover --------------> U 32) TestFirmwareDiagStatus ----------> . In case the output doesn’t come as expected, physically pull out and reseat the module firmly in the chassis to hard-reset the module. After the module is up again, capture the output of the command “show module” and “show diagnostic module all” Here is an example of failed diagnostic test for module 1 Module 1: Catalyst 6000 supervisor 2 (Active) SerialNo : Overall Diagnostic Result for Module 1 : MINOR ERROR Diagnostic level at card bootup: minimal Test results: (. = Pass, F = Fail, U = Untested) 1) TestSPRPInbandPing --------------> F 2) TestTransceiverIntegrity: 13
  • 14. 2. Overruns on some ports on Card 5 (WS-X6548-GE-TX) Switch1# show interface counters Noticed "overruns" on 4 interfaces. They were not incrementing GigabitEthernet5/1 is up, line protocol is up (connected) Full-duplex, 1000Mb/s, media type is 10/100/1000BaseT 0 input errors, 0 CRC, 0 frame, 26 overrun, 0 ignored GigabitEthernet5/6 is up, line protocol is up (connected) Full-duplex, 1000Mb/s, media type is 10/100/1000BaseT 0 input errors, 0 CRC, 0 frame, 14 overrun, 0 ignored GigabitEthernet5/9 is up, line protocol is up (connected) Full-duplex, 1000Mb/s, media type is 10/100/1000BaseT 0 input errors, 0 CRC, 0 frame, 159 overrun, 0 ignored GigabitEthernet5/12 is up, line protocol is up (connected) Full-duplex, 1000Mb/s, media type is 10/100/1000BaseT 0 input errors, 0 CRC, 0 frame, 269 overrun, 0 ignored Also will enabling switch fabric rectify the overruns? Solution: Enabling switch fabric will not rectify overruns because after the installation of a Switch Fabric Module in a Cisco Catalyst 6500 series switch, the traffic is forwarded to and from modules in different modes which doesn't necessarily facilitate resolution for overruns. The traffic is forwarded in one of these of these modes: 14
  • 15. a) Flow-through mode: In this mode, data passes between the local bus and the supervisor engine bus. This mode is used for traffic to or from modules that are not fabric-enabled. b) Truncated mode: Only truncated data (the first 64 bytes of the frame) goes over the switch fabric channel if both the destination and the source are fabric-enabled modules. If either the source or destination is not a fabric-enabled module, the data goes through the switch fabric channel and the data bus. The Switch Fabric Module does not get involved when traffic is forwarded between modules that are not fabric-enabled. c) Compact mode: A compact version of the DBus header is forwarded over the switch fabric channel, which delivers the best possible switching rate. Modules that are not fabric-enabled do not support the compact mode and generate cyclic redundancy check (CRC) errors upon receipt of frames in compact mode. This mode is used only when no such modules are installed in the chassis. Let’s understand what overrun is:- Overrun - The number of times the receiver hardware was unable to hand received data to a hardware buffer Common Cause - The input rate of traffic exceeded the ability of the receiver to handle the data. From the given example, the module used is WS-X6548-GE-TX: This module is 8:1 oversubscribed. The ports on this module go to servers. On these modules there is a single 1-Gigabit Ethernet uplink from the port ASIC that supports eight ports. These cards share a 1 Mb buffer between a group of ports (1-8, 9-16, 17-24, 25- 32, 33-40, and 41-48) since each block of eight ports is 8:1 oversubscribed. The aggregate throughput of each block of eight ports cannot exceed 1 Gbps. These line cards are oversubscription cards that are designed to extend gigabit to the desktop and might not be ideal for server farm connectivity. For more information refer to:- Troubleshooting Switch Port and Interface Problems To resolve this issue of overrun, move the high volume servers to ports on different asic groups, so that the traffic flow through the 8 ports of every asic group does not exceed 1 Gbps. Alternatively look for other ideal design recommendations on line cards that have better oversubscription ratio. It refers from: https://supportforums.cisco.com/document/71201/switch-fabric- troubleshooting-tips 15
  • 16. More related: The Differences of XFP, SFP and SFP+ How to Identify the Genuine Cisco SFP? Basic Knowledge on Cisco SFP Modules Technical Specifications for Cisco SFP Modules More Cisco products and Reviews you can visit: http://www.3anetwork.com/blog 3Anetwork.com is a world leading Cisco networking products supplier, we supply original new Cisco networking equipments, including Cisco Catalyst switches, Cisco routers, Cisco firewalls, Cisco wireless products, Cisco modules and interface cards products at competitive price and ship to worldwide. Our website: http://www.3anetwork.com Telephone: +852-3069-7733 Email: info@3Anetwork.com Address: 23/F Lucky Plaza, 315-321 Lockhart Road, Wanchai, Hongkong 16