This document provides an overview and catalog of various accessories for dissolution testing equipment manufactured by ELECTROLAB, including vessels, baskets, paddles, cannulas, filters, and more. It describes the appropriate uses and specifications of different accessory types in accordance with USP standards. Maintenance tips are also provided to help preserve the quality and longevity of the accessories.
2. 2
Index
USP 2 (Paddle)
8-12USP 1 (Basket)
Vessels
Dissolution Testers
Stand and Ring
Jar Lids
Cannulas
Filters
Dispensor Plate and Top plate
Leur Locks and Vials
Jar Locks and Bath Rod
Water Bath
Validation kit
TM
kloudbase
Stop Watch
Sinkers
12-13
14-17
19
20
21
22
18
22-23
23
24
4-5
4-35
6
6
7
7
Low Volume Conversion Kit 24
USP 3 (Reciprocating Dissolution Tester) 25
USP 7 (Reciprocating Dissolution Tester) 26
3. 3
Index
Common Accessories for Pumps
Friability Testers
Disintegration Testers
Leak Tester
Peristaltic Pumps
Tap Density Tester
Electromagnetic Sieve Shakers
Tablet Hardness TestersH
Diffusion Cell Apparatus
Dissolution Media Preparator
TM
STARLITE-12
Enhancer Cells
51
39
37-38
46
47-50
44-45
41-43
40
deconex Cleaners and Disinfectants 34
32-33
35
35
36
34
USP 5 (Paddle Over Disc) 30
USP 6 - Rotating cylinder/ Transdermal cylinder 31
P Tassist
27-29Accessories for Reciprocating Dissolution Tester (Model : ERD-03 and ERD-07)
4. 4
Vessels
Vessel Capacity
1000 mL
2000 mL
4000 mL
Height Inner Diameter
Ø98 mm- 106 mmØ
Ø Ø98 mm- 106 mm
Ø Ø145 mm- 155 mm
USP vessel dimensions specification ELECTROLAB vessel dimensions specification
Seam
Bulls-eye
Elongated
Flattened
ELECTROLAB Vessels
Use of genuine ELECTROLAB accessories is recommended
to avoid errors in physical / chemical validation / calibration of
ELECTROLAB instruments
Vessel USP compliance conformity certificate
Narrower tolerance for ELECTROLAB Vessels
ELECTROLAB compliance range
98 mm 106 mmUSP compliance range
105
Internal diameter
103
USP<711>vesseldefinition
coveredvesselmadeofglassorotherinert,transparentmaterial
Ÿ Iscylindricalwithahemisphericalbottom
Ÿ Foranormalcapacityof1liter,theheightis160mmto210mmanditsinsidediameteris98mmto106mm
Ÿ Itssidesareflangedatthetop
The USP states the dimensions for glass vessels, the tolerances are actually quite wide leading to a different dimension for
vessels for each manufacturer. This means that vessels cannot easilybe interchanged and that it is never advisable to substitute
lessthanacompletesetofalternativevesselsandeventhenre-validationmightberequired.
Vessel Capacity
1000 mL
2000 mL
4000 mL
Height
164.5mm-166.5mm
275 mm - 291 mm
289 mm - 291 mm
Inner Diameter
Ø103 mm-Ø105 mm
Ø Ø103 mm- 105 mm
Ø Ø149 mm- 151 mm
150 mL Ø Ø46 mm- 36 mm 150 mL 123.5mm-125.5mm Ø40 mm-Ø42 mm
Dissolution Testers
160 mm - 210 mm
280 mm - 300 mm
280 mm - 300 mm
119.5 mm - 129.5mm
5. 5
Glass vessel
250 mL (clear)
Part no - 0104A00002
Glass vessel
150 mL (clear)
Part no - 0104A00291
Glass vessel
2000 mL (clear)
Part no - 0122A00002
Glass vessel
1000 mL (clear)
Part no - 0104A00004
Glass vessel
1000 mL (amber)
Part no - 0104A00005
Flat bottom
1000 mL (clear)
Part no - 0104A00012
TM
Kone vessel
1000 mL (clear)
Part no - 0104A00010
Laser marked glass vessel
1000 mL (clear)
Part no - 0104A00023
E E
EE E
E
E
E
Merlon vessel
1000 mL (clear)
Part no - 0104A00242
E
New
Merlon vessel
1000 mL (amber)
Part no - 0104A00259
E
New
Vessels
Dissolution Testers
150 ml
E
Part No.
0133A00001
0133A00002
Description
Glass Vessel 4000 mL (clear)
Glass Vessel 4000 mL (amber)
6. 6
Vessel centering ring for glass vessel
suitable for composite top plate (Set of 8)
Part no - 0104A00140
Vessel centering ring for merlon vessel
suitable for composite top plate (Set of 8)
Part no - 0104A00141
Cares & Maintenance
Ÿ For longer and safe life of glass vessel use ELECTROLAB glass jar stand
Ÿ Clean glass & Merlon vessel with mild detergent or soap
Jar Lids
Moulded jar lid - plastic
(Set of 6)
Part no - 0104A00041
Jar lid for staggered start
white (Set of 6)
Part no - 0104A00044
Low evaporation jar lid
composite (Set of 6)
Part no - 0104A00042
E E
E E E
Rubber stand for
glass vessel
Part no - 0104A00040
E
Dissolution Testers
Stand and Ring
7. 7
Dissolution Testers
Cannulas
Filters
Sampling cannula
fixed height for 1000 mL
(Set of 6) Length 92 mm
Part no - 0104A00045
Sampling cannula
peak (Set of 6)
Part no - 0104A00049
Adjustable sampling cannula
for jar lid (Set of 6)
Length 127 mm
Part no - 0104A00047
Sampling cannula
for 2000 mL vessel
Part no - 0104A00048
Disposable filters (Pkt of 100)
Part no - 0104A00050
SS filters with holder (Set of 6)
Part no - 0104A00051
Inline Filters
0.45 micron (Set of 6)
Part no - 0104A00052
Part No. Description
0104A00046 Adjustable sampling cannula for tablet input device (Set of 6) Length 144 mm
0104A00156 Sampling cannula fixed height 900 mL (Set of 6) Length 98 mm
0104A00157
0104A00295
Sampling cannula fixed height 750 mL (Set of 6) Length 108 mm
Sampling cannula fixed height 150 mL (Set of 6)
0104A00233 Sampling cannula fixed height 250 mL (Set of 6) Length 65 mm
E E E
E
E E E
Part No.
0104A00308
Description
Inline filters - 0.22 micron (Set of 6)
8. 8
USP Apparatus 1 - Basket
Dosage Form
Basket Shaft
Sampling Point
A
Vessel
Basket
Adopted in 1970 the rotating basket method of dissolution testing was the first
officialmethod.Itessentiallyconsistsofanapproximately1inch(25.4mm)×13/8
inch (34.925mm) stainless steel, 40-mesh wire basket rotated at a constant speed
between 25 and 150rpm. This method is now called apparatus 1 (or Method 1).
The apparatus consists of a metallic drive shaft connected to the cylindrical
basket. The basket is positioned inside a vessel made of glass or other inert,
transparent material. The vessel contents are kept at a constant temperature by
being placed inside a water bath or heating jacket. The solution in the vessel is
stirred smoothly by the rotating basket. The USP apparatus 1 requires a 40-mesh
screen unless otherwise specified in the monograph. Other meshes can be used
tosolveindividualproblems.
Usefulfor
Ÿ Capsules
Ÿ Beads
Ÿ Delayedrelease/entericcoateddosageforms
Ÿ Floatingdosageforms
Ÿ Surfactantsinmedia
Advantages
Ÿ Breadthofexperience(morethan200monographs)
Ÿ FullpHchangeduringthetest
Ÿ Canbeeasilyautomatedwhichisimportantforroutineinvestigations
Standardvolume
Ÿ 900/1000mL
Ÿ 1,2,4Litrevessels
Goldplatedbasket
A pure gold plating up to 2.5µm thickness is allowed by the USP for use in acid
media or where the active drug reacts with the plain steel basket. If gold is used,
the shaft as well as the basket should be coated. Uncoated baskets deteriorate
from contact with acid and they become less rugged and are more likely to distort
duringassemblyonthedriverod.
Uniqueidentification
All baskets and shafts should be uniquely identified, documented, and kept in the
samepositioninthesametestassemblyforalldissolutionruns.
Dissolution Testers
9. Basket 80 mesh
(Set of 6)
Part no - 0104A00059
Basket 100 mesh
(Set of 6)
Part no - 0104A00060
Gold plated basket
(Set of 6)
Part no - 0104A00061
Basket 10 mesh
(Set of 6)
Part no - 0104A00054
Basket 60 mesh
(Set of 6)
Part no - 0104A00058
Basket 20 mesh
(Set of 6)
Part no - 0104A00055
Basket 40 mesh
(Set of 6)
Part no - 0104A00057
9
Baskets
Stationary basket (Set of 6)
Part no - 0104A00062
Felodipine basket with spacer (Set of 6)
Part no - 0104A00063
Basket 30 mesh
(Set of 6)
Part no - 0104A00056
Basket 40 mesh Ø24.5 mm
(Set of 6)
Part no - 0104A00204
Holder for basket
40 mesh 24.5 mm (Set of 6)
Part no - 0104A00206
EE E E
EE E E
E E
Laser marked basket
40 mesh
Part no - 0104A00075
E
E120549
E E
Basket conformity certificate
New
Dissolution Testers
10. 10
Basket Lids
Basket lid 10 mesh
(Set of 6)
Part no - 0104A00070
Basket lid 40 mesh
(Set of 6)
Part no - 0104A00071
E E
Basket 'O' ring
(Set of 6)
Part no - 0104A00067
E
Part No.
0104A00205
Description
Lid for basket
40 mesh 24.5 mm
(Set of 6)
Moulded Tray for Baskets and Shafts
Moulded tray for baskets & shafts
Part no - 0104A00152
E
Moulded tray for basket
Part no - 0104A00065
E
Moulded tray for paddles
Part no - 0104A00093
E
Cares & Maintenance
Ÿ Baskets can be effectively and gently cleaned by placing them in a beaker of alcohol and
sonicatingforfiveminutesandthenallowingthemtoairdry
Ÿ Alwaysholdthebasketviathetoplipofthebasketandavoidputtingpressureonthemesh
Ÿ Forlongerandsafelifeofbaskets,storetheminspeciallydesignedstoragecontainers
Dissolution Testers
Basket holder with
Part no - 0104A00069
'O' ring (Set of 6)
Basket Shaft and Holder
E
Basket shaft
Part no - 0104A00066
E
Part No.
0122A00007
0133A00004
Description
Basket shaft for 2000 mL vessel (Set of 6)
Basket shaft for 4000 mL vessel (Set of 6)
11. 11
Mesh integrity microscope (EMM-01)
Part no - 0104A00202
E
Patented Design
Verification Tool for Mesh
Ÿ Application of Mesh Integrity Microscope is to check and confirm the 'mesh
consistency, wire diameter, wire opening, surface etching, uneven diameters
ofmeshandsizeofbasket.
Ÿ ConnectedtocomputerwithUSBport,plug-inplay&easytooperate.
Ÿ Software with measurement function, real time full screen display, capture
imagesforarchival,recordingandreplayoption.
Ÿ Provided with certificate & calibration chip. Calibration of mesh integrity
microscopecanbedoneatsite.
Ÿ Smallerfootprinthencerequireslessspace.
Ÿ Lightweightenablesittobecarriedeasily.
Basket validation gauge with certificate
Part no - 0104A00154
Verification Tool for Basket
Cares & Maintenance
Ÿ
Ÿ
Alwaysholdthebasketviathetoplipofthebasketandavoidputtingpressureonthemesh
Storethebasketsinspeciallydesignedstoragecontainers
E
Ÿ Compliant to USP, Ph. Eur and JP
specifications
Ÿ Basket Validation Gauge not only
controls the parameters set in USP
<711> (height, cylinder ID and OD)
but also controls the cylinder
symmetry
Ÿ Helps in reducing investigation
report
Ÿ 1 min verification thereby saving
time
Ÿ Helpsinincreasingproductivity
Dissolution Testers
Weundertakeelectropolishingofbasket&re-Certificationofbasket.
12. 12
Dosage Form
E-10266-1E-10266-1
USP Apparatus 2 - Paddle
Cares & Maintenance
Ÿ ELECTROLAB suggests that paddles ‘may’ be coated with polyfluorocarbon. Such coating
serves two purposes: it prevents corrosion and the introduction of unwanted ions into the
media and it seals the joint where the blade is attached to the shaft, thus preventing the
accumulationoftracesofcontaminants
Apparatus 2, commonly known as the paddle method, has similar
physical specifications to those of Apparatus 1 with a paddle substituted
for the rotating basket. Some of the dimensions and tolerances for the
paddle are critical if consistent results are to be obtained from vessel to
vessel. The USP specifies that the paddle must rotate smoothly without
significant wobble. The arc of the paddle blade creates considerable
flow and any wobble will have an exaggerated effect on the flow profile.
The contours of the paddle blade must not include any sharp edges at
the tips for instance that could produce turbulent instead of laminar
flow patterns. The USP constrains wobble and vertical alignment with
theaxisofthevesseltowithin±2.0mm.
Usefulfor
Ÿ Tablets
Ÿ Capsules
Ÿ Beads
Ÿ Delayed release / enteric coated dosage forms
Advantages
Ÿ Easy to use
Ÿ Robust
Ÿ Can be easily adapted to apparatus 5
Ÿ Long experienced
Ÿ pH change possible
Ÿ Can be easily automated which is important for routine
investigations
Standard volume
Ÿ 900/1000 mL
Ÿ 1, 2, 4 Litre vessels
Dissolution Testers
13. 13
Paddles
Cares & Maintenance
Ÿ For longer and safe life of paddles, store them in specially designed storage containers
Paddle for enhancer cell
(Set of 6)
Part no - 0104A00088
Mini paddle for 150 mL
glass vessel (Set of 6)
Part no - 0104A00293
Mini paddle for 250 mL
glass vessel (Set of 6)
Part no - 0104A00084
Paddle for 1000 mL glass vessel
(Set of 6)
Part no - 0104A00085
Laser marked paddle for 1000 mL glass vessel
0104A00091
(Set of 6)
Part no -
Teflon paddle (Set of 6)
Part no - 0104A00087
Part No.
0122A00004
0133A00003
Description
Paddle for 2000 mL glass vessel (Set of 6)
Paddle for 4000 mL glass vessel (Set of 6)
E Part no. 0103A00085 P - 1503104
E
E E
E
E
New
Dissolution Testers
14. 14
Sinkers
Indissolutiontesting,theU.S.Pharmacopeiaallows,asavariationtoApparatus2,anon-reactivestainlesssteelwirehelixasa
‘sinker’ to be typically used to sink dosage forms that would otherwise float. The objective of this investigation was to
determineifothersinkershapeswillinfluencetherate,extent,orvariabilityofdissolution.Criteriafortheoptimalsinkerwere
defined.Variousnewsinkerdesignswerefabricated,tested,andclassified.
Fourclassesofsinkershapesweredefined:
Ÿ Longitudinal
Ÿ Lateral
Ÿ Screenenclosures
Ÿ Internalweights
Longitudinal sinkers contact the dosage forms on the long axis. Lateral sinkers either wrap around or contact capsule dosage
forms in the middle, such as the line where the top and bottom halves of a capsule shell come together. Screen enclosures are
of two types: either a wire cage, which holds the entire capsule,or a circular piece of wire screen placed on top of the capsule.
Internalweightsconsistoftwosteelballbearings,oneinsertedintoeachendofthecapsule.
Thechoiceofsinkerwilldependonthetabletorcapsule.Ingeneraltherearesomeguidelinesthatcanbefollowed,however:
Ÿ The sinker should ideally not touch the tablet as this can effect the dissolution rate. They are available in different sizes to
accommodatemostcapsule/tabletdimensions.
Ÿ Aminimumamountofweightispreferable,justenoughtohavethedesiredeffect
Ÿ Coatedsinkerscanbeusedwheretheremaybeareactionbetweensteelandthetablet
Ÿ Baskettypesinkerscanbeusedbutcareshouldbetakenthattheoutercoatingofthetabletdoesnotclogthemesh.
Ÿ Wirespiralsshouldbeaswideaspracticallypossibletoavoidcloggingwhichwilleffectthedissolutionrate.
JapanesesinkersarespecifiedbytheJP&USPandhavestrictdimensions.
E
Dissolution Testers
15. 15
Sinker 11 mm ID X 31 mm IL
(Set of 6)
Part no - 0104A00097
Sinker 6 mm ID X 18 mm IL
(Set of 6)
Part no - 0104A00095
Sinker 5 mm ID X 15.5 mm IL
(Set of 6)
Part no - 0104A00094
Sinker 8 mm ID X 23 mm IL
(Set of 6)
Part no - 0104A00096
E E E E
Part no.
Part no.
0104A00094
0104A00098
0104A00095
0104A00245
0104A00096
0104A00220
0104A00097
0104A00218
Inside diameter
Inside diameter
5
12
6
15
8
12
11
15
Inside length
Length
15.5
25
18
25
23
25
31
40
Vertical rod 10 12 N.A. 12
Coating
Coating
Electropolish
Electropolish
Electropolish
Electropolish
Electropolish
Electropolish
Electropolish
Electropolish
MOC
MOC
SS 316
SS 316
SS 316
SS 316
SS 316
SS 316
SS 316
SS 316
MOC SS 316 - SS 316 SS 316
E E
Japanese sinker
(Set of 6)
Part no - 0104A00098
E
Japanese sinker
with 40 mesh cover (Set of 6)
Part no - 0104A00220
Customized japanese sinker
15 ID X 25 Height (Set of 6)
Part no - 0104A00245
E
Customized japanese sinker
15 ID X 40 Height (Set of 6)
Part no - 0104A00218
E
Spring type sinker-big
(Set of 6)
Part no - 0104A00101
Teflon coated sinker
Spring type (Set of 6)
Part no - 0104A00103
Helical coil sinker
CAPWHT-02 (Set of 6)
Part no - 0104A00115
E E
Helical coil sinker
CAPWHT-2S (Set of 6)
Part no - 0104A00116
E
Part No. 0104A00101 0104A00103 0104A00115 0104A00116
Inside diameter 10 10 9 12
Inside length 28 28 25 27
Coating Electropolish Teflon Teflon Electropolish
Sinker details
Sinker details
Sinker details
Sinkers
Dissolution Testers
16. 3 prong sinker - Plastic
(Set of 6)
Part no - 0104A00104
3 prong sinker (SS)
(Set of 6)
Part no - 0104A00105
EE
Part no. 0104A00104 0104A00105
Top diameter 5 N.A
3 prong rod diameter 2.70 3
3 prong rod height 28 28
MOC
Coating
Nylon
N.A
SS 316
Electropolish
Metformin sinker-
big (Set of 6)
Part no - 0104A00113
E
Metformin sinker-
small (Set of 6)
Part no - 0104A00114
E
Part no. 0104A00114
Height 30.48
Inner dimensions 13.76
14.63
Inner thickness 5.48
Outer thickness 6.35
Coating
Coating
MOC
MOC
Electropolish
Electropolish
SS 316
SS 316
Outer dimensions
16
Part no. 0104A00099 0104A00100
Inside diameter 16 1212
Total length with lid 13 8.58.5
Cage type sinker-
big (Set of 6)
Part no - 0104A00099
Cage type sinker -
small (Set of 6)
Part no - 0104A000100
E E
Customized sinkers are also available
0104A00113
30.48
14.097
14.96
10.26
11.12
Electropolish
Electropolish
SS 316
SS 316
Sinker details
Sinker details
Sinker details
Sinkers
Dissolution Testers
17. Spring type sinker - small
(Set of 6)
Part no - 0104A00102
Helical coil sinker
L 2.4 cm D 0.1 cm & GAPS 0.5 cm
(Set of 6)
Part no - 0104A00112
E
Alfuzosin sinker
37.5 mm ID x 10 mm OD
(Set of 6)
Part no - 0104A00107
E E
17
1 inch helix type sinker (Set of 6)
Teflon coated sinker (22 mm long & 13 cm length of gauge wire)
Description
0103A00111
0103A00163
Part No.
EE
Sinkers
Dissolution Testers
18. 18
1 2 3 4
5 6 7 8
Tablet dispenser plate for 8 vessels
Part no - 0104A00159
Bath top plate - aluminum for 8 glass vessels
Part no - 0104A00310
Dispensor Plate
Dispenser plate holder (Set of 2)
Part no - 0104B00048
Part No.
0105A00159
Description
Tablet dispensor plate for 14 vessels
Part No.
0105A00311
Description
Bath top plate – aluminum for 14 glass vessels
E E
New
Dissolution Testers
Top Plate
E
19. 19
Luer Locks
Luer lock - BSMLRL-6 (male)Luer lock - MLRL210-6 (male) Luer lock - FTLL220-6 (female)
Luer lock - FSLLR-1 (female)Luer lock - BSFTL6-210-6 (female) Luer lock - MTLL220-6 (male)
Luer lock - MTLL410-6 (male)Luer lock - MTLL240-1 (male) Luer lock - FTL210-6 (female)
Luer lock - FTLL240-1 (female)Luer lock - FTLL210-6 (female) Luer lock - PMLP-21 (male)
Luer lock - FTLLB230-1 (female) Luer lock - FTLLL6 (female)
Part no. Description
0110AFC006 Glass vials 15 mL (amber)
0110AFC002 Glass vials 10 mL (amber)
0114ASC003
----------------
Glass tubes 10 mL (clear)
Glass vials 20 mL (clear)
0114ASC004
----------------
Glass tubes 10 mL (amber)
Glass vials 20 mL (amber)
Glass tubes
25 mL (clear)
Part no. 0114ASC001
Glass vials
15 mL (clear)
Part no. 0110AFC005
Glass vials
10 mL (clear)
Part no. 0110AFC001
0114ASC002 Glass tubes 25 mL (amber)
E E E
E E
E
E E E
E E E
E E
E E
E
Vials and Tubes
New
Dissolution Testers
20. 20
Jar lock for glass vessel
for composite top plate (Set of 16)
Part no - 0104A00138
suitableJar lock for glass vessel
suitable for S.S. top plate (Set of 16)
Part no - 0104A00132
Jar Locks
Bath Rod
Jar lock for merlon vessel
suitable for S.S top plate (Set of 16)
Part no - 0104A00133
V-1234 External probe
Part no - 0104B00018
E
E E
E
E
E
E
E
E
Bath rod (Set of 2)
Part no - 0104A00151
Dissolution Testers
21. 21
Water Bath
E
8
Water bath with plastic QRC (clear) for 8 vessels
Part no - 0104A00143
Side circulation water bath (clear) with assembly for 14 vessels
Part no - 0105A00307
New
E
3
2
4
5
7
6
Dissolution Testers
1
Inlet & outlet connector for ETC-11 - Part no. 0104B00031
Plastic quick release coupling with shut off valve (Set Of 2) - Part no. 0104A00146
Water circulation tygon tube set for 8 vessels - Part no. 0104B00058
Drain rubber for water bath - Part no. 0104B00051
Tygon tube for drainage - Part no. 0104A00309
Drainage valve - Part no. 0104B00025
Tygon tubing set for ETC - 15 for water bath
1
Rubber leg for water bath - Part no. 0104B000522
3
4
5
6
7
8
Part No. Description
0104A00144
0104A00307
0105A00144
0105A00143 Water bath with plastic QRC (clear) for 14 vessels
Water bath with plastic QRC Smoke grey for 8 vessels
Side circulation water bath (clear) with assembly for 8 vessles
Water bath with plastic QRC Smoke grey for 14 vessels
22. 22
(Patented Design)
Validation Kit (digital )
Centering device for
1000 mL vessel
Part no - 0104A00119
Centering guage
Part no - 0104A00120
Digital tachometer
Part no - 0104A00122
Basket validation gauge
with certificate
Part no - 0104A00154
Digital verticality meter
Part no - 0104A00125
Digital thermometer
Part no - 0104A00124
Gauge block 25 mm
Part no - 0104A00160
Digital depth gauge
Part no - 0104A00155
E
E E
E
E
E
E
E
Dissolution Testers
Accessory for visual observation and recording of dissolution test
iDisso-06u (compatible with most make of 6 / 8 dissolution testers)
Part no.
TM
0164A00001
TM
BlackOut curtain for iDisso-06u
iDisso-12 (compatible with EDT-14Lx)
TM
TDT-14L/
Description
TM
BlackOut curtain for iDisso-12
0164A00002
0105A00198
Part No.
0105A00332
E
New
23. 23
Thermometer - Mercury
Part no - 0104A00123
Validation Kit (analog)
Validation kit (analog)
Part no - 0104A00118
Depth gauge for 1000 mL vessel
Part no - 0104A00121
Digital tachometer
Part no - 0104A00122
Basket validation gauge with certificate
Part no - 0104A00154
Centering device for 1000 mL vessel
Part no - 0104A00119
Centering guage
Part no - 0104A00120
E E E
E
E
E
Where
Time
DeviceANYANY
Access dissolution test information
kloudbase
TM
Description
TM
Kloudbase server
Kloudbase annual licenseTM
Part No.
0103A00199
0103A00200
Accessory to access dissolution test information anywhere, anytime & on any device
Dissolution Testers
E
New
24. 24
Low Volume Conversion kit
150 mL low volume conversion kit for 8 vessels
Part no - 0104A00303
Stop watch
Part no - 0104A00185
Inside Caliper 6”
Part no - 0104A00182
E
150 ml
E
E E E E
Part No. Description
0104A00213 250 mL low volume conversion kit for 8 vessels
0105A00304 150 mL low volume conversion kit for 14 vessels
0105A00213 250 mL low volume conversion kit for 14 vessels
E
Dissolution Testers
E
New
Stop Watch and Inside Caliper
25. 25
Dosage Form
The reciprocating cylinder was proposed by Beckett and coworkers and its
incorporation into the USP followed in 1991. The idea to generate a new test
method came from a presentation at the International Pharmaceutical
Federation (FIP) Conference in 1980 (U.S. Pharmacopoeial Convention).
In this presentation, problems with the dissolution results from USP
Apparatuses I and II, which may be affected physical factors like shaft wobble,
location, centering, deformation of the baskets and paddles, presence of the
bubbles in the dissolution medium, etc. were enumerated. It was agreed at the
conference that major problems could arise in the acceptance of
pharmaceutical products in international trade due to the resultant variations
inthedissolutiondata.
A team of scientists working under Beckett's direction in London, UK,
subsequently developed the reciprocating cylinder, which is often referred to
as the ''Bio-Dis.'' Although primarily designed for the release testing of
extended-release products, USP apparatus 3 may be additionally be used for
the dissolution testing of IR products of poorly soluble drugs. In terms of
design, the apparatus is essentially a modification of the USP/NF disintegration
tester.
Usefulfor
Ÿ Capsules
Ÿ Beads
Ÿ Delayed release / enteric coated dosage forms
Advantages
Ÿ Easy to use
Ÿ Robust
Ÿ Can be easily adapted to apparatus 5
Ÿ ph change possible
Ÿ Can be easily automated which is important for routine investigations
Standard volume
Ÿ 900/1000 mL
Ÿ 1 Litre vessels
USP Apparatus 3 - Reciprocating Dissolution Tester
Dissolution Testers
26. 26
Dosage Form
Typical Dosage Holder
Apparatus 7 Reciprocating holder is used for transdermal patches &
solids. The assembly consists of a set of volumetrically or tared solution
containers. A motor and drive assembly to reciprocate the system
vertically, a set of suitable sample holders. The solution containers are
partially immersed in a suitable water bath, inside the temperature of the
containers at 32 ± 0.5°C. Several different pH media can be used in
succession with the Apparatus 7, so that with extended release drugs you
can simulate the conditions of the body throughout the drugs path.
apparatus 7 can provide low volume for very low dose drugs, it typically
has a volume of 50 mL (and as low as 25 mL ) in each tube as opposed to
900mLintraditional apparatus1or2
Other variables such as the height setting and sampling requirements are
thesameasforUSPMethod1.
Usefulfor
Ÿ Transdermal patches
Ÿ Extended release products
Ÿ Osmotic devices (OROSTM)
Ÿ Stents
Ÿ pH profiles
Standard volume
Ÿ 20-200 mL
Advantages
Ÿ Small volumes possible
Ÿ Selection of holder types
Ÿ pH can be easily changed
Different holder types
Ÿ Acrylic Rod: extended release tablets, osmotic devices (OROSTM)
Ÿ Angled Disk : transdermal systems
Ÿ Teflon cylinder : transdermal systems
Ÿ Spring holder : extended release tablets
Ÿ Reciprocating disk : transdermal systems
Dissolution Testers
USP Apparatus 7 - Reciprocating Dissolution Tester
27. 27
(50 mL) vessel
Part no - 1102A00029
(100 mL) vessel
Part no - 1101A00001
(300 mL) vessel
Part no - 1101A00002
(1000 mL) vessel
Part no - 1101A00003
Reciprocating cylinder
Description
Reciprocating cylinder (100 mL)
Reciprocating cylinder (1000 mL)
Part no.
1101A00021
1101A00023
Reciprocating cylinder (300 mL)
Part no - 1101A00022
Evaporation cap
Evaporation cap (300 mL)
Part no - 1101A00018
Description
Evaporation cap (50 mL)
Evaporation cap (1000 mL)
Evaporation cap (100 mL)
Part no.
1102A00030
1101A00019
1101A00017
E E E E
E
Dissolution Testers
Accessories for Reciprocating Dissolution Tester (Model : ERD-03 and ERD-07)
E
28. 28
Accessories for Reciprocating Dissolution Tester (Model : ERD-03 and ERD-07)
Description
Vessel stand (50 mL)
Vessel stand (1000 mL)
Vessel stand (100 mL)
Part no.
1102A00031
1101A00006
1101A00004
Vessel stand (300 mL )
Part no - 1101A00005
Vessel Stand
USP 3 and 7 arm
Part no. 1101A00020
Acrylic rod / Acrylic stick
Part no. 1102A00025
Description
Transdermal system holder - cylinder
Reciprocating disc holder
Transdermal system holder - angled Disk
Part no.
1102A00026
1102A00028
1102A00027
E
E
E
Dissolution Testers
USP Apparatus Arm
29. 29
SS 316 screen (20 mesh)
Part no - 1101A00012
SS 316 screen (40 mesh)
Part no - 1101A00013
SS 316 screen (60 mesh)
Part no - 1101A00014
SS 316 screen (80 mesh)
Part no - 1101A00015
SS 316 screen (100 mesh)
Part no - 1101A00016
Description
Spring holder
Spring holder (Oral extended release tablet holder)
size : 1.45 mm x 0.58 mm
Part no - 1102A00021
E
Description
Spring Holder (Oral extended release tablet holder) size : 1.40 mm x 0.31 mm
Spring Holder (Oral extended release tablet holder) size : 0.96 mm x 0.33 mm
Spring Holder (Oral extended release tablet holder) size : 0.60 mm x 0.25 mm
Part no.
1102A00022
1102A00024
1102A00023
Part no.
1101A00007
1101A00009
1101A00011
1101A00008
1101A00010
Accessories for Reciprocating Dissolution Tester (Model : ERD-03 and ERD-07)
Dissolution Testers
E
E E
E E
Polypropylene screen (20 mesh)
Polypropylene screen (60 mesh)
Polypropylene screen (80 mesh)
Polypropylene screen (100 mesh)
Polypropylene screen (40 mesh)
30. 30
Paddle
E10266-1
Dissolution Vessel
Disk Assembly
Paddle over disc-33 (Set of 6)
Part no. 0104A00168
Paddle over disc-50 (Set of 6)
Part no - 0104A00169
Paddle over disc-55 (Set of 6)
Part no - 0104A00170
Paddle over disc-65 (Set of 6)
Part no - 0104A00171
Paddle disc-85 (Set of 6)
Part no - 0104A00172
over
USP Apparatus 5 - Paddle Over Disc
Cares & Maintenance
Ÿ Always take care to eliminate air bubbles between the substrate and the release surface in
paddle over disc method
With paddle over disc, a transdermal patch is placed either between a glass disc and an
inert PTFE mesh , or directly onto a stainless steel mesh. This is placed at the bottom of
the vessel,with the mesh facing upwards, under a rotating paddle. Transdermal testing
is carried out at 32°C to reflect the temperature of the skin. Other variables such as the
heightsettingandsamplingrequirementsarethesameasforUSPmethod2.
Usefulfor
Ÿ Transdermalpatches
Standardvolume
Ÿ 900 mL
Temperature
Ÿ 32°C
Advantages
Ÿ Standard equipment (paddle) can be used, only add a stainless steel disk
assembly
Alternative
Ÿ “Sandwich” / watchglass
Ÿ USP 30 footnote :
Ÿ A suitable device is the watchglass-patch-polytef mesh sandwich assembly
TM
available as the Transdermal Sandwich
Ÿ Accepted by the FDA
EE
E E E
Dissolution Testers
31. 31
Dosage Form
Intrinsic attachment
Part no - 0104A00128
Transdermal cylinder
Height 50.8 mm (Set of 6)
Part no - 0104A00184
Transdermal cylinder
Height 107.9 mm (Set of 6)
Part no - 0104A00183
USP Apparatus 6 - Rotating Cylinder / Transdermal Cylinder
The USP 6 rotating cylinder is similar to USP Method 1 (the rotating basket). With USP
Method 6 however, the basket assembly is replaced by a solid stainless steel cylinder. The
transdermal patch is fixed to the outside surface of the cylinder. Transdermal testing is
carried out at 32°C to reflect the temperature of the skin.
Other variables such as the height setting and sampling requirements are the same as for
USP Method 1.
Useful for
Ÿ Transdermal patches
Standard volume
Ÿ 900 mL
Temperature
Ÿ 32°C
Advantages
Ÿ Standard apparatus can be used
Ÿ Variable volumes
Ÿ Larger patch sizes can be tested
Bench Press
Description
0103A00129
Part no.
Cares & Maintenance
Ÿ Do not exert excess pressure on the punch, it can damage both punch & die
Ÿ Immediate cleaning of apparatus should be done by water or Isopropyl alcohol (IPA)
Ÿ Always store the Intrinsic Dissolution Apparatus in dry place
EE E
Dissolution Testers
32. 32
Glass diffusion cell with purging
5 mL – 15 mm Orifice
1001A00029Part No.
Glass diffusion cell without purging
5 mL – 15 mm Orifice
1001A00028Part No.
Description
Glass diffusion cell without purging -7.5 mL – 15 mm Orifice
Glass diffusion cell without purging -5 mL – 30 mm Orifice
Glass diffusion cell without purging -7.5 mL – 30 mm Orifice
Glass diffusion cell without purging -12 mL – 30 mm Orifice
Glass diffusion cell with purging -7.5 mL – 15 mm Orifice
Glass diffusion cell with purging -5 mL – 30 mm Orifice
Glass diffusion cell with purging -7.5 mL – 30 mm Orifice
Glass diffusion cell with purging -12 mL – 30 mm Orifice
Part no.
1001A00030
1001A00002
1001A00006
1001A00010
1001A00032
1001A00004
1001A00008
1001A00012
1001A00031
1001A00003
1001A00007
1001A00011
Glass diffusion cell without purging -12 mL – 15 mm Orifice
Glass diffusion cell without purging -5 mL – 34 mm Orifice
Glass diffusion cell without purging -7.5 mL – 34 mm Orifice
Glass diffusion cell with purging -12 mL – 34 mm Orifice
1001A00033
1001A00005
1001A00009
1001A00013
Glass diffusion cell with purging -12 mL – 15 mm Orifice
Glass diffusion cell with purging -5 mL – 34 mm Orifice
Glass diffusion cell with purging -7.5 mL – 34 mm Orifice
Glass diffusion cell with purging -12 mL – 34 mm Orifice
E E
Diffusion Cell Apparatus (Model : EDC-07/ EDC-02)
Dissolution Testers
33. 33
Donor cap close 5 mL (Set of 7)
Part no. 1001A00021
Donor cap open 5 mL (Set of 7)
Part no. 1001A00022
Clamp plate 5 mL (Set of 7)
Part no. 1001A00019
Cell cap (Set of 7)
Part no. 1001A00016
Part no. 1001A00017
Magnetic candy 3x6 mm (Set of 7) Donor Washer 5 mL (Set of 7)
Part no. 1001A00020
Themb nut
1001A00037Part no.
EE E
E
E E E
Description
Adjustable leg with check nut (Set of 4)
Clamp plate 7.5 mL/ 12mL (Set of 7)
Acrylic cell holder with SS plate (Set of 7)
Donor washer 7.5 mL/ 12mL (Set of 7)
Part no.
1001A00001
1001A00023
1001A00015
1001A00025
1001A00014
1001A00024
Holder sealing rubber (Set of 7)
Donor cap close 7.5 mL/ 12mL (Set of 7)
1001A00018
1001A00026
Magnetic candy 3x10 mm (Set of 7)
Donor cap open 7.5 / 12 mL (Set of 7)
1001A00034
1001A00036
Cylinder jacket
S S Clamp - Binder type
1001A00035 S S Clamp -Screw type
Dissolution Testers
Diffusion Cell Apparatus (Model : EDC-07/ EDC-02)
34. deconex (Cleaners and Disinfectors)
Enhancer Cells (for ointment, suspension & emulsion)
Cares & Maintenance
Ÿ Assembling, disassembling, tightening of any part of enhancer-cell
shouldbedonewithcarebecauseextremeforcecandamagetheparts
Ÿ Always use specialized and customized tool designed for the
adjustmentofenhancer-cell
Applications
Laboratory : Chemical residues in glasswares
Instruments : Analytical and medical instruments
and many more . . .
deconex 12 basic (20 bottles of 500 mL)
Part no - 0104A00203
34
Model : ERB-16A and ERB-16W
Bottle (100 mL) with cap – clear
Description
Model : ERB-40A and ERB-40W
Bottle (10 mL) with cap – clear
Description
0801A00001
Part no.
0803A00001
Part no.
E
Dissolution Testers
Bottle Rotating Apparatus
E
EE
E
E E
E
35. 35
Dissolution Testers
P Tassist
Prerequisites
Cares & Maintenance
Ÿ Most labs choose to get the instrument requalified every 6 months. It is recommended to
requalify the instrument one week before requalification date to avoid the appearance of
non-compliance
ELECTROLAB offers PVTassist by trained dissolution experts to assist in maintaining proper
dissolutionapparatusqualification,whichincludes:
Ÿ Enhancedmechanicalcalibrationofthedissolutionapparatus
Ÿ UsageofstandardoperatingprocedurestomaximizetheprobabilityofsuccessofPVT
Ÿ PVTperformanceanddocumentationbythespecialist
Ÿ ELECTROLABCertificateofapparatuscompliance
Ÿ Appropriatedegassing,filtrationandmediaheatingfacility
Ÿ Consumables (eg. Prednisone USP tablets, Prednisone USP RS, Ethanol, 0.45 micron filters,
glasswares)
Ÿ ELECTROLABgenuineaccessories
TM
STARLITE-12
Ÿ Thermal Paper with 12 years life
Ÿ Use STARLITE-12 in weighing scale printers (impact printers) for
increased life of printer head.
Ÿ
Length: Width:
Shelflife:
Sensitivity:
Protectioncoating:
Stability:
Printability:
Other:
GMP regulations from PIC/S, USFDA and EU regulations require
maintenance of accurate back-up files of input data for a minimum
period of 5 years which should be secured from alteration, loss or
inadvertent erasure.
If a record is poorly documented, then the manufacturing or QA/QC of aŸ
productcanbenegativelyimpacted,potentiallyreducingit’sreliability.
• 700cm, 5.7cm(Customizedsizesalsoavailable)
• 3-5years
• High
• Topcoat
• Highlystableagainstenvironmentalinfluences
• Excellentprintabilityofthermalcoatingside
• Phenolfree
Features
TM
STARLITE-12
Thermal paper roll (Set of 24)
Part no. 0905A00007
E
New
36. Model : EMP - 21
Prime holder
Part no - 0701A00003
Nozzle tip (SS) with filter
Part no - 0701A00005
Nozzle tip filter (SS)
Part no - 0701A00006
Hose assembly with handle
Part no - 0701A00002
Rubber gasket for tank
Part No - 0701A 00001
Optical Dissolved Oxygen (DO) Meter
Dissolution Media preparator
DO
Part no - 0701A00007
Meter36
Ÿ No calibration, no membrane, no electrolyte, no drift
Ÿ No cross sensitivity with pH 1-14, C0, HS, SO2
Ÿ Real time temperature, salinity and pressure compensation
Ÿ Fast response sensor
Ÿ No O consumption: Precision in low O concentrations2 2
Ÿ ASTM International method D 888-05 compliance
E
E
E
E E
E
E
Media aspiration holder
Part no - 0701B00001
37. Model : ED-2L, ED-2AL, ED-2 SAPO and ED-3PO
Glass tube for six tube basket
assembly (Set of 6)
Part no - 0201A00001
Glass tube for three tube
bolus basket assembly (Set of 6)
Part no - 0201A00002
Guided disc for three tube bolus
basket assembly (Set of 6)
Part no - 0201A00005
Glass tube for single tube
bolus basket assembly (Set of 2)
Part no - 0201A00003
Guided disc for single tube bolus
basket assembly (Set of 2)
Part no - 0201A00006
Magnetic guided disc (Set of 12)
Part no - 0201A00007
ED-2L / 2AL - Six tube basket assembly
with guided disc (Set of 2)
Part no - 0202A00009
ED-2L / 2AL -
assembly with guided disc (Set of 2)
Part no -
Three tube bolus basket
0202A00010
ED-2L / 2AL - External probe
Part no - 0202A00014
Single tube bolus basket assembly
with guided disc (Set of 2)
Part no - 0202A00011
Glass beaker (1000 mL)
Part no - 0201A00013
Guided disc for six tube
basket assembly (Set of 6)
Part no - 0201A00004
37
EE
E
E
E E E
E E
E E
EE
E
E
E
Disintegration Testers
E E
E
E
E
E
E E
E
E
E
E
E
E
E
E E
E
E E
E E
38. 38
Cares & Maintenance
Ÿ Thoroughcleaningofthebasketisrecommendedforaccurateandreliableresults
Ÿ Theentirebasketassemblycanbedisassembledwithoutusinganyspecialtool
Ÿ Duringthecleaningprocess,therubberretainerwillpreventthetubesfromfalling
Ÿ The use of online visual verification of stroke amplitude may assure the user of compliance
withregulatorystandards
SAPO -
with guided disc (Set of 2)
Part no - 0201A00010
Three tube bolus basket assembly SAPO -
with guided disc (Set of 2)
Part no - 0201A00011
Single tube bolus basket assemblySAPO - Six tube basket assembly
with guided disc (Set of 2)
Part no - 0201A00009
Disc stopper (Set of 2)
Part no - 0201A00019
EE
E
Disc handling device
Part no - 0201A00018
SAPO - External probe
Part no - 0201A00016
Bath sensor
Part no - 0201B00044
E E
E
EE E
E E EE E E
E
E
Disintegration Testers
Model : ED-2L, ED-2AL, ED-2 SAPO and ED-3PO
39. 39Friability drum
Part no - 0402A00009
Tablet collection tray with SS drawer
Part no - 0402A00002
o
10 Tilt with rear side legs (Set of 2)
Part no - 0402A00005
Rubber "O" ring for
knob & drum
Part no - 0402A00010
Abrasion drum
Part no - 0402A00008
Tablet collection tray with SS drawer
Part no - 0401A00002
Drum locking knob
Part no - 0401A00001
Tablet collection SS drawer
Part no - 0402A00003
E E E
E E
E
E E
Friability Testers
Model : EF-2WEF-2 &
40. 40
Brush
Part no - 0901A00002
Force gauge
Part no - 0902A00003
Brass weight 5 kg (Calibrated)
Part no - 0901A00001
Hook
Part no - 0901A00004
24 Column thermal printer
Part no - 0902A00005
Printer cable
Part no - 0902A00006
H
Cares & Maintenance
Ÿ Bouncing the weight on the calibration platform while placing the weight may lead to permanent
damageoftheloadcell
Ÿ It is advised not to run the machine without proper locking and tightening both the locking knobs,
thismayresultinanabnormalsoundandcandamagethemachine
H
E E E
E
E E
Communication cable
Part no - 0901A00007
E
We also supply 500 gm, 1kg, 2kg, calibrated weight in brass and SS
Tablet Hardness Testers
Model : EH-01 and EH-01P
41. 41
Lid & receiver for
200 mm dia test sieves
Part no - 0501A00004
Bakelite knob fit
locking arm (Set of 2)
Part no - 0501A00001
Lid & receiver for
100 mm dia test sieves
Part no - 0501A00005
Vertical rod (Set of 2)
Part no - 0501A00065
Test sieves of 100 mm dia
(ASTM No. 200 - 75 micron)
Part no - 0501A00059
Test sieves of 200 mm dia
(ASTM No. 100 - 150 micron)
Part no - 0501A00026
Wet sieve
attachment for 200 mm Dia
Part no - 0501A00006
TM
SieveEasy software CD
Part no - 0501A00068
Locking arm (Horizontal)
for 200 mm dia test sieves
Part no - 0501A00002
(Same arm can be use for 100 mm dia test sieves)
E E E
E E E
E E
E
New
Electromagnetic Sieve Shakers
Model : EMS-8
42. 42
Part No.
0501A00014
0501A00015
0501A00008
0501A00009
0501A00010
0501A00011
0501A00012
0501A00013
0501A00025
0501A00026
0501A00027
0501A00028
0501A00029
0501A00030
0501A00031
0501A00032
0501A00033
0501A00034
0501A00035
0501A00036
0501A00037
0501A00038
0501A00039
0501A00040
0501A00041
0501A00042
0501A00043
0501A00044
0501A00045
0501A00046
0501A00047
0501A00048
0501A00049
0501A00051
0501A00052
0501A00050
0501A00016
0501A00017
0501A00018
0501A00019
0501A00020
0501A00021
0501A00022
0501A00023
0501A00024
0501A00007
Continued....
EMS-8 Test sieves of 200 mm dia (ASTM No. 16 - 1.18 mm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 18 - 1.00 mm)
Description
EMS-8 Test sieves of 200 mm dia (ASTM No. 6 - 3.35 mm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 5 - 4.00 mm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 7 - 2.80 mm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 8 - 2.36 mm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 10 - 2.00 mm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 12 - 1.70 mm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 14 - 1.40 mm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 80 - 180 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 100 - 150 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 120 - 125 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 140 - 106 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 170 - 90 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 200 - 75 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 230 - 63 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 270 - 53 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 325 - 45 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 400 - 38 µm)
EMS-8 Test sieves of 200 mm dia (Micron 28 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 5 - 4.00 mm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 6 - 3.35 mm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 7 - 2.80 mm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 8 - 2.36 mm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 12 - 1.70 mm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 14 - 1.40 mm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 16 - 1.18 mm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 10 - 2.00 mm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 18 - 1.00 mm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 20 - 850 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 25 - 710 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 30 - 600 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 35 - 500 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 40 - 425 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 50 - 300 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 60 - 250 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 45 - 355 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 20 - 850 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 25 - 710 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 30 - 600 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 35 - 500 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 40 - 425 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 45 - 355 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 50 - 300 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 60 - 250 µm)
EMS-8 Test sieves of 200 mm dia (ASTM No. 70 - 212 µm)
Electromagnetic Sieve Shakers
Model : EMS-8
43. 43
Cares & Maintenance
Ÿ Cleansievesbysonicatingtheminwateroraspecialdetergent(Eg.deconex12)toensureaccurateand
reproduciblesievingresults
Ÿ It is advice not to run the machine without proper locking and tightening both the locking knobs, this
mayresultinanabnormalsoundandcandamagetheinstrument
Test sieves of 100 mm dia (Micron 28 µm)
Description
EMS-8 Test sieves of 100 mm dia (ASTM No. 325 - 45 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 400 - 38 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 70 - 212 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 80 - 180 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 100 - 150 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 120 - 125 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 140 - 106 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 170 - 90 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 200 - 75 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 230 - 63 µm)
EMS-8 Test sieves of 100 mm dia (ASTM No. 270 - 53 µm)
0501A00064
Part No.
0501A00062
0501A00063
0501A00053
0501A00054
0501A00055
0501A00056
0501A00057
0501A00058
0501A00059
0501A00060
0501A00061
We undertake re-certification of ELECTROLAB make test sieve and other make test sieve too.
Electromagnetic Sieve Shakers
Model : EMS-8
44. 44
Measuring cylinder 250 mL class ‘B’ without certificate
Measuring cylinder 100 mL class ‘B’ without certificate
Measuring cylinder 50 mL class ‘B’ without certificate
Measuring cylinder 10 mL class ‘B’ without certificate
Measuring cylinder 25 mL class ‘B’ without certificate
Description
0301A00006
0301A00008
0301A00010
Part No.
0301A00004
0301A00002
Please ask Electrolab's service engineer / sales person, to confirm
whether your existing Tap Density is compliant to current USP criteria
Model : ETD - 1020
Measuring cylinder
100 mL class ‘A’ with certificate
Part no - 0301A00001
Measuring cylinder
50 mL class ‘A’ with certificate
Part no - 0301A00005
Measuring cylinder
250 mL class ‘A’ with certificate
Part no - 0301A00003
Measuring cylinder
10 mL class ‘A’ with certificate
Part no - 0301A00007
Measuring cylinder
25 mL class ‘A’ with certificate
Part no - 0301A00009
E
E
E E E
Tap Density Tester
45. 45
Adapter for 50 mL measuring cylinder
Part no - 0301A00011
Cylinder holder
250 mL measuring cylinder
Part no - 0301A00018
for
Cylinder holder for 100 mL
Measuring cylinder
Part no - 0301A00017
Acoustic cabinet
Part no - 0301A00014
Cares & Maintenance
Ÿ It is advised to lock the cylinder holder properly before starting the test. Not doing so
couldleadtoaccidents&breakageofglasswares.
Tap Density Tester
Adapter for 10 mL
Part no - 0301A00012
measuring cylinder
E
Adapter for 25 mL
Part no -
measuring cylinder
0301A00013
E
E
E
E
E
Please ask Electrolab's service engineer / sales person, to confirm
whether your existing Tap Density is compliant to current USP criteria
Model : ETD - 1020
46. 46 Vacuum dessicator of
for 300 mm dia
Part no - 5001A00009
Rubber gasket
for 250 mm dia dessicator
Part no - 5001A00003
Vacuum dessicator
for 250 mm dia
Part no - 5001A00008
12 mm round glass plate
for 300 mm dia dessicator
Part no - 5001A00002
12 mm round glass plate
for 250 mm dia dessicator
Part no - 5001A00001
Methylene Blue Dye Test Method (Model : LT-101P)
E
E
Perforated disc
for 250 mm dia dessicator
Part no - 5001A00005
E
Perforated disc
for 300 mm dia dessicator
Part no - 5001A00006
E
EE
Rubber gasket
for 300 mm dia dessicator
Part no - 5001A00004
Leak Tester
E
E
47. Acrylic “C” cover
Part no - 0601A00003
Moulded “C”
Part no - 0601A00002
Roller assembly
Part no - 0601A00006
Pump head (Roller assembly with
moulded “C” and acrylic cover)
Part no - 0601A00008
“H” for Roller assembly
Part no - 0601A00007
E E
Tube holding jaw (Set of 2)
Part no - 0601A00004
E E E
E
PP-50V/ 201V Silicon tubing 3 mm ID x 6 mm OD
PP-50V Silicon tubing 2 mm ID x 5 mm OD
DescriptionPart No.
PP-50V/ 201V Silicon tubing 4 mm ID x 7 mm OD
PP-50V/ 201V Silicon tubing 1 mm ID x 4 mm OD
0601A00010
0601A00009
0601A00011
0601A00016
Model : PP-50V / VX
47
Peristaltic Pumps
48. Tube holding jaw (Set of 2)
Part no - 0607A00004
Acrylic “C” cover
Part no - 0607A00003
Moulded “C”
Part no - 0607A00002
“H” for Roller assembly
Part no - 0607A00007
Roller assembly
Part no - 0607A00006
Jaw clamp
Part no - 0607A00005
E E E
E E E
Pump Head (Roller assembly
with moulded “C” and acrylic cover)
Part no - 0607A00008
E
Silicon tubing 3 mm ID x 6 mm OD
Silicon tubing 2 mm ID x 5 mm OD
Silicon tubing 4 mm ID x 7 mm OD
Description
0607A00011
Part No.
0601A00010
0601A00009
0607A00012
0607A00013
0607A00014
Silicon tubing 5 mm ID x 8 mm OD
Silicon tubing 6 mm ID x 9 mm OD
Silicon tubing 8 mm ID x 11 mm OD
Model : PP-201V
48
Peristaltic Pumps
49. 49
Moulded “C”
0616A00023Part no -
Moulded “C” with acrylic cover
Part no - 0619A00001
S.S Nozzle for Silicon Tubing
10 mm ID x 13 mm OD (Set of 2)
Part no - 0616A00023
PP-301V Pump head (Roller assembly with
Moulded “C” and acrylic cover and nozzle)
Part no - 0619A00006
Roller assembly
Part no - 0619A00004
Acrylic “C” cover
Part no - 0619A00003
EE
E E E
E
Silicon tubing 5 mm ID x 8 mm OD
Silicon tubing 3 mm ID x 6 mm OD
Silicon tubing 6 mm ID x 9 mm OD
DescriptionPart No.
0616A00028
Silicon tubing 8 mm ID x 11 mm OD
Silicon tubing 10 mm ID x 13 mm OD
0616A00012
0616A00011
0607A00014
0616A00009
Model : PP-301V
Silicon tubing 12 mm ID x 15 mm OD0616A00010
Ÿ SS Nozzle are also available as per the silicon tubing
sizes
Ÿ We also supply Derlin teflon nozzle as per the
tubingsizes
Peristaltic Pumps
50. Moulded “C”
Part no - 0619A00002
Nozzle for tubing (Set of 2)
Part no - 0619B00005
Roller assembly
Part no - 0619A00004
50
E E
Moulded “C” with acrylic cover
Part no - 0619A00001
Pump head (Roller assembly with
Moulded “C” and acrylic cover)
Part no - 0619A00006
Silicon tubing 8 mm ID x 14 mm OD
Silicon tubing 6 mm ID x 12 mm OD
Silicon tubing 10 mm ID x 16 mm OD
Description
0619A00014
Part No.
0619A00012
060A100022
Silicon tubing 12 mm ID x 18 mm OD
Silicon tubing 15 mm ID x 21 mm OD
Silicon tubing 19 mm ID x 25 mm OD0619A00009
0619A00008
0619A00007
E
Model : PP-401V
Ÿ SS Nozzle are also available as per the silicon tubing
sizes
Ÿ Wealsosupplyteflonnozzleasperthetubingsizes
E
E
Peristaltic Pumps
51. 51
Model : PP-50V, PP-50VX, PP-201V, PP-301V and PP-401V
Front panel for
50 FCH / CS -
201 FCH - 0609B00001
201 CS - 0610B00001
0603B00001
Front panel for
50 V / 201 V - 0601B00012
301 V - 0616B00001
Front panel for
50V FLP - 0602B00001
201V FLP - 0608B00001
301V FLP - 0617B00001
Front panel for
401 V - 0619B00004
Front panel for
50 VT - 0604B00001
201 VT / 401 VT
Front panel for 52 LCS / 202 LCS
Front panel for 50 VX Foot-switch Proxy sensor
EE E
E
E
E
E E
E
PP-50V / 201V / 301V Toggle switch
Part no - 0601B00007
PP-50V / 201V / 301V Push button
Part no - 0601B00008
E E
Peristaltic Pumps
52. Our Products
• Complete range of Dissolution Testers • Dissolution Media Preparator • Disintegration Testers • Friability Testers
• Tablet Hardness Testers • Electromagnetic Sieve Shakers • Tap Density Tester • Bulk Density Tester
• Powder Flow Tester • Leak Tester • Peristaltic Pumps
The information contained in this document is believed to be correct but ELECTROLAB accepts no liability for any errors and reserves the right to alter specifications without notice
September, 2015 / 00AC001
CE
ELECTROLAB
Sales
&
Service
Worldwide
Head Office : 401, Tirupati Udyog, I. B. Patel road, Off. Western Express highway, Goregaon (East), Mumbai - 400 063, India.
Tel : +91-22-4041 3131 • E-mail : sales@electrolabindia.com
Factory : EL 23/24, T. T. C., Electronic Zone, M. I. D. C, Mahape, Navi Mumbai - 400 710, India.
Tel : + 91 - 22 - 4161 3131 • Website : www.electrolabindia.com