SPECIFICATIONS
Lasertype - Semiconductorlaser/GaAl As
Outputpower - 40mW (Max)
Laserprobe - Pointed&Cluster
Wavelength - 650nm
Treatmenttime - 0- 99mins
Laserclassification - ClassIIIBLaser
Therapyforms - Continuous /Pulsed (50%
pulsedduration) 5-2000Hz
Display - 128x64GraphicLCDDisplay
The DIGILASER is an advanced and modern designed unit for laser therapy with interchangeable laser probe.
Laser therapy, also known as photo biomodulation, Low Level Laser Therapy (LLLT), cold laser therapy, and as
laserbiostimulationisaneffectivemethodfor:
FEATURES
Automatic Calculation of Joules & Power
Choice Two Probes Pointer & Cluster
International Standards and
Specifications
Large Graphic LCD Display
Light Weight and Easy to Operate
Plastic Moulded Cabinet
Laser Productive Goggles
Cap-sense keys
APPLICATIONS
Dermatological Conditions
Rheumatic Conditions
Degenerative Joint Disease
Post-Traumatic and Post-Operative
Conditions
Rheumatoid Arthritis
Conditions for which acupuncture is
indicated
v
vSoft Tissue Injury Treatment
vWound Healing
vSkin Treatment (esp. for Acne)
vHair fall control / Regrowth
Pain Management v
vCosmetic Regeneration
vResolving Viral and Bacterial Infections
vDiabetic wound healing
Nerve Regeneration
TECHNICALDATA
Mainsvoltage - 90-270V/ 50or60Hz
Safetyclass - Class I, Type BF (IEC
60601-1)
Dimensions - LxBxHx29x21x11cm
Weight - 1.7Kgs
HMS Medical Systems
#9, 1st Cross Street, New Colony, Porur, Chennai - 600116.
Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773
Web : www.hms.co.in email : sales@hms.co.in
9126
The DIGILASER 203 is an advanced and modern designed unit for laser therapy with interchangeable laser
probe with auto detection. Fully computerised 5.7” Colour LCD with touch screen display. Laser therapy, also
known as photo biomodulation, Low Level Laser Therapy (LLLT), cold laser therapy, and as laser
biostimulation isan effectivemethodfor:
DIGILASER 203
HMS Medical Systems
#9, 1st Cross Street, New Colony, Porur, Chennai - 600116.
Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773
Web : www.hms.co.in email : sales@hms.co.in
COMPUTERISED LASER THERAPY
v
vSoft Tissue Injury Treatment
vWound Healing
vSkin Treatment (esp. for Acne)
Pain Management v
vCosmetic Regeneration
vResolving Viral and Bacterial Infections
vDiabetic wound healing
Nerve Regeneration
FEATURES
Autoprobedetection
IRwithvisibleRedlasercombination
Built-in Rechargeablebattery
Microcontrolerbased
5.7”ColourLCDwithtouch screen
Lightweightplasticcabinet
APPLICATIONS
DermatologicalConditions
RheumaticConditions
DegenerativeJointDisease
Post-TraumaticandPost-OperativeConditions
RheumatoidArthritis
Conditionsforwhich acupunctureisindicated
SPECIFICATIONS
Lasertype - Semiconductorlaser/GaAl As
Laserprobe
810nm - 300mW pointed(module)
650nm - 40mW pointed(module)
650nm - 200mW cluster(diode)
Treatmenttime - 0-60mins
Laserclassification - Class3Baccording to
IEC -60825- 1
TECHNICALDATA
Mainsvoltage - 90-270V/ 50or60Hz
Dimensions -
Weight - 2.5Kgs
LxBxH–28x22x9cms
ACCESSORIES
9126
EN ISO 13485: 2012 + AC: 2012
DIGIMED
COMPUTERISED INTERFERENTIAL THERAPY
FEATURES
35 Pre-programs condition wise with protocols
Cable and electrode checking mode
User settable memory
Light weight and compact design
Easy to operate
future upgrade without change in hardware
DSP Based circuitry, outputs are in 100% accuracy
Large graphic LCD display
International standards and specifications
Advanced patient safety system
PC Interfacefacility(infuture)
Cap-sensekeys
Builtinrechargeablebattery(optional)
The DIGIMED is an advanced interferential therapy equipment in the field of electrotherapy. In the
development of the unit simplicity of operation and functionality were the principle consideration. All the
available types of current and therapy are clearly displayed on a large LCD screen. The corresponding
parameters are easily set with 5 Soft touch keys. Pro-pragrammed memory with treatment applications
offers protocols for more than 35 frequently occuring indications and users can store their settings in user
memorylocationsandeasilyrecall theirprogramsfortheirpatients.
SPECIFICATIONS
Carrierfrequency - 2000Hz / 4000Hz
Basefrequency - 0-150Hz (1Hz step)
Sweep frequency - 0-150Hz (1Hz step)
Sweep modulation
Programs - 1/1S 1/5, 1/5S 6/6S
TherapyModes - FourpoleInterferential
o
FourpoleVector90
o
FourpoleVector45
Twopolepre-modulated
Outputcurrent - 0- 100mA
Timer - 0 -60mins
Mainsvoltage - 90-270V/ 50or60Hz
SafetyClass - ClassI,TypeBF(IEC60601-1)
Dimensions - LxBxH-30x25x10.5cms
Weight - 2.5Kgs
TECHNICALDATA
HMS Medical Systems
#9, 1st Cross Street, New Colony, Porur, Chennai - 600116.
Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773
Web : www.hms.co.in email : sales@hms.co.in
9126
EN ISO 13485: 2012 + AC: 2012
ACCESSORIES
DIGISONIC
Advanced and trend setter Ultrasound therapy from HMS R&D. DIGISONIC is designed indigenously with international
standards with incomparable quality. The DIGISONIC comes with 1 MHZ and 3 MHZ outputs. Micro controller based
circuitry with large LCD display for viewing all parameters. 30 pre-programs and 20 re-writable user settable memory.
Easilyselectablecontinuousand9pulsedmodessofttouchkeysforallfunctions.
FEATURES
1 MHZ and 3 MHZ outputs in
single transducer
Large LCD display
30 Pre-programmes
20 User settable memory
Water resistant transducer
User friendly
Light weight plastic moulded
cabinet
Cap-sense keys
Plastic moulded water resistant
transducer
SPECIFICATIONS
Frequency - 1MHZand3MHZ
Therapymodes - Continuous/ Pulsed
Pulsesettings/Hz - 9Settings/ 100Hz
2
Outputpower - 0- 3W/cm
Timer - 0- 60mins
MainsVoltage - 90- 270V/ 50or60Hz
Safety Class -
Dimensions - L x B x H – 28 x 22 x 9 cms
Weight - 2.3 Kgs
Class I, Type BF (IEC 60601 -1)
TECHNICAL DATA
COMPUTERISED 1 & 3 MHZ ULTRASOUND THERAPY
HMS Medical Systems
#9, 1st Cross Street, New Colony, Porur, Chennai - 600116.
Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773
Web : www.hms.co.in email : sales@hms.co.in
9126
EN ISO 13485: 2012 + AC: 2012
DIGISTIM
DIGISTIM is a computerized stimulator unit with therapeutic,lontoporasis and TENS facility. Treatment mode, treatment
time and other parameters are displayed in the LCD. Soft touch membrane keys are used to select the modes and
parameters. Digital Display Indicates the output current in mA. In IG mode Rectangular / Triangular pulses can be
selectable.
SPECIFICATIONS
Treatment modes - Iontophorosis, Galvanic,
Int.Galvanic,Faradic,Surged
Faradic, TENS, TENS Burst
INT. GAL
Therapeutic - 30 – 300 mSec (1 mSec step)
Diagnostic - 01, .03, .3, 1, 3, 10, 30, 100,
300 mSec
Pulse type - Square, Triangular
FARADIC
Freq./ P.width - 50 Hz / 7 mSec
Surge ON time - 1 – 10 sec (1 sec step)
Surge OFF time - 1 – 6 sec (1 sec step)
TENS
Frequency - 2 – 250 Hz in (1 Hz step)
P.Width - 20–250 sec (1m sec step)
Output current - 0 – 50 mA
Timer - 0 – 60 mins
FEATURES
Microcontroller based stimulator cum TENS
LCD display for therapy type and treatment time
User friendly with soft touch key functions
Light weight plastic moulded cabinet
Mainsvoltage - 220V/ 50 Hz
Safety class -
Dimensions - L x B x H – 23 x 20 x 8 cms
Weight - 2 Kgs
TECHNICALDATA
Class I, Type BF (IEC 60601 -1)
COMPUTERISED MUSCLE STIMULATOR WITH TENS
HMS Medical Systems
#9, 1st Cross Street, New Colony, Porur, Chennai - 600116.
Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773
Web : www.hms.co.in email : sales@hms.co.in
9126
EN ISO 13485: 2012 + AC: 2012
DIGISTIM EMS is a specially designed Pocket model Stimulator unit for physiotherapy students and home visit
therapists. It has three modes IG, F & SF. IG duration / SF intervals can be varied by single control. Micro-controller
basedcircuitryhelpsustomakeitcompactandsleek. Itcanbeoperatedbybattery/mains.
SPECIFICATIONS
TreatmentModels - IG, F,SF
IG - 30–150 mSec.
FARADIC
Freq./P.width - 50 Hz / 0.7 mSec
Surge Duration - 1–6 sec
Power Source - 9 V Battery / Adaptor
FEATURES
Battery/ Mainsoperated
Microcontroller based circuitry
Handy model
DIGISTIM EMS
MICRO STIMULATOR - POCKET MODEL
First time
in
INDIA
HMS Medical Systems
#9, 1st Cross Street, New Colony, Porur, Chennai - 600116.
Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773
Web : www.hms.co.in email : sales@hms.co.in
9126
EN ISO 13485: 2012 + AC: 2012
DIGITENS is an advanced hand held dual Channel Pocket model TENS in the field of Electrotherapy.The microcontroller
based circuitry has six preprogrammed output modes that can be selectable by a soft touch key. It has 15 mins built in
timeranditwillbeoperatedbybattery/ mains.
FEATURES
Sixpreprograms
Micro-controller controlled circuitry
Battery / Adaptor
Built-in 15 min timer
Separate intensity control for both channels.
DIGITENS
SIX PROGRAMMED DUAL CHANNEL TENS
HMS Medical Systems
#9, 1st Cross Street, New Colony, Porur, Chennai - 600116.
Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773
Web : www.hms.co.in email : sales@hms.co.in
9126
EN ISO 13485: 2012 + AC: 2012
DIGITENS 104 is an advanced micro controller based Four Channel TENS from HMS R & D. Unique design with manual
and 20 pre-programs. Used for both fitness and therapeutic purpose. Soft touch keys for selection of programs. Built in
batterywith10hrs backupindigenousdesignwithinternationalstandards.
SPECIFICATIONS
TensFrequency - 2–250Hz(1HzStep)
Pulse width - 20 – 250 micro seconds
No.of Channels - Four
Output mode - Continuous/Pulsed
Frequency Sweep - Available
Treatment Time - 0 – 60 min
Pre-program - 1-15 Pain Relieving Program
16-20 Fitness Program
Display - 128 / 64 Graphic LCD Display
Power Source - Dual Power (Mains/Battery)
FEATURES
4Channel Outputs
Micro controller based circuitry
Manual Cum preprograms facility
Obesity Program
Universal Input
Built In Re-chargeable battery with 10 hrs Back-up
ABS Cabinet-Portable & Light Weight
MainsInputVoltage - 90V–270VAC
Battery - Maintenance free rechargeable
Safety Class -
Dimensions - L x B x H – 21 x 22.5 x 6.5 cms
Weight - 1.75 Kgs
TECHNICALDATA
Class I, Type BF (IEC 60601 -1)
DIGITENS 104
DIGITENS 104
HMS Medical Systems
#9, 1st Cross Street, New Colony, Porur, Chennai - 600116.
Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773
Web : www.hms.co.in email : sales@hms.co.in
9126
EN ISO 13485: 2012 + AC: 2012
DIGITRAC is continuous and intermittent traction unit. It is ideal for both cervical and lumbar traction. It is the first
indigenous product of its kind. Built in Micro – controller for accuracy and consistency. Soft touch membrane keys are
used to select the parameters. Bar graph display indicates the traction force. Weight and hold time/rest time can be set
with 1 unit step. Traction force from 3 kg to 45 kgs (upto 90 kgs with doubler) High quality improved heavy duty D C motor
fordurabilityandsmoothfunction.
SPECIFICATIONS
Max.Wt. - 3-45Kgs(1Kgsteps)
(90Kgswithdoubler)
Min.Wt. - 0-44 Kgs (1 Kg steps)
Hold Time - 1–99 Seconds (1 sec step)
Rest Time - 1–99 Seconds (1 sec step)
Treatment Time - 1–99 minutes (1 min. step)
Input Voltage - 90 – 270 V, 50/60 Hz
Safety Class -
Dimensions - L x B x H–12 x 11.3 x 11 inches
Weight - 8 Kgs
TECHNICAL DATA
Class I, Type BF (IEC 60601 -1)
FEATURES
Microcontrollerbased
Accurate weight settings
Real weight sensing mechanism
Wide input Voltage range
Soft touch switches
Easy to operate
Compete with international standards
DIGITRAC
COMPUTERISED CERVICAL / LUMBER TRACTION
HMS Medical Systems
#9, 1st Cross Street, New Colony, Porur, Chennai - 600116.
Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773
Web : www.hms.co.in email : sales@hms.co.in
9126
EN ISO 13485: 2012 + AC: 2012
DIGIVAC
DIGIVAC is an advanced Computerised Vacuum therapy unit with continuous and pulsed output. Can be integrated with
UNISTIM. DIGIMED,SONOMED andINDOMEDseries.
FEATURES
Continuous&Pulsed
Low Noise & vibration
Flexible Output cable & Electrodes
Light Weight, User friendly
Connect with any Model IFT
Bio-Compatible Electrodes
Universal Input (90-270V AC)
SPECIFICATIONS
Vacuum Pressure - 100 to 600 m bar (Continuously
Adjustable)
Output Mode - Pulsed / Continuous
Number of Electrodes - Four
Mains Voltage - 90–270 V / 50/60 Hz
Dimensions - L x B x H – 30 x 20.5 x 10 cms
Weight - 2.2 Kgs
TECHNICAL DATA
COMPUTERISED VACUUM THERAPY
HMS Medical Systems
#9, 1st Cross Street, New Colony, Porur, Chennai - 600116.
Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773
Web : www.hms.co.in email : sales@hms.co.in
9126
EN ISO 13485: 2012 + AC: 2012
H. M. S. Medical Systems, Chennai, Ultrasound Device

H. M. S. Medical Systems, Chennai, Ultrasound Device

  • 23.
    DIGILASER EN ISO 13485:2012 + AC: 2012 COMPUTERISED LASER THERAPY EQUIPMENT SPECIFICATIONS Lasertype - Semiconductorlaser/GaAl As Outputpower - 40mW (Max) Laserprobe - Pointed&Cluster Wavelength - 650nm Treatmenttime - 0- 99mins Laserclassification - ClassIIIBLaser Therapyforms - Continuous /Pulsed (50% pulsedduration) 5-2000Hz Display - 128x64GraphicLCDDisplay The DIGILASER is an advanced and modern designed unit for laser therapy with interchangeable laser probe. Laser therapy, also known as photo biomodulation, Low Level Laser Therapy (LLLT), cold laser therapy, and as laserbiostimulationisaneffectivemethodfor: FEATURES Automatic Calculation of Joules & Power Choice Two Probes Pointer & Cluster International Standards and Specifications Large Graphic LCD Display Light Weight and Easy to Operate Plastic Moulded Cabinet Laser Productive Goggles Cap-sense keys APPLICATIONS Dermatological Conditions Rheumatic Conditions Degenerative Joint Disease Post-Traumatic and Post-Operative Conditions Rheumatoid Arthritis Conditions for which acupuncture is indicated v vSoft Tissue Injury Treatment vWound Healing vSkin Treatment (esp. for Acne) vHair fall control / Regrowth Pain Management v vCosmetic Regeneration vResolving Viral and Bacterial Infections vDiabetic wound healing Nerve Regeneration TECHNICALDATA Mainsvoltage - 90-270V/ 50or60Hz Safetyclass - Class I, Type BF (IEC 60601-1) Dimensions - LxBxHx29x21x11cm Weight - 1.7Kgs HMS Medical Systems #9, 1st Cross Street, New Colony, Porur, Chennai - 600116. Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773 Web : www.hms.co.in email : sales@hms.co.in 9126
  • 24.
    The DIGILASER 203is an advanced and modern designed unit for laser therapy with interchangeable laser probe with auto detection. Fully computerised 5.7” Colour LCD with touch screen display. Laser therapy, also known as photo biomodulation, Low Level Laser Therapy (LLLT), cold laser therapy, and as laser biostimulation isan effectivemethodfor: DIGILASER 203 HMS Medical Systems #9, 1st Cross Street, New Colony, Porur, Chennai - 600116. Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773 Web : www.hms.co.in email : sales@hms.co.in COMPUTERISED LASER THERAPY v vSoft Tissue Injury Treatment vWound Healing vSkin Treatment (esp. for Acne) Pain Management v vCosmetic Regeneration vResolving Viral and Bacterial Infections vDiabetic wound healing Nerve Regeneration FEATURES Autoprobedetection IRwithvisibleRedlasercombination Built-in Rechargeablebattery Microcontrolerbased 5.7”ColourLCDwithtouch screen Lightweightplasticcabinet APPLICATIONS DermatologicalConditions RheumaticConditions DegenerativeJointDisease Post-TraumaticandPost-OperativeConditions RheumatoidArthritis Conditionsforwhich acupunctureisindicated SPECIFICATIONS Lasertype - Semiconductorlaser/GaAl As Laserprobe 810nm - 300mW pointed(module) 650nm - 40mW pointed(module) 650nm - 200mW cluster(diode) Treatmenttime - 0-60mins Laserclassification - Class3Baccording to IEC -60825- 1 TECHNICALDATA Mainsvoltage - 90-270V/ 50or60Hz Dimensions - Weight - 2.5Kgs LxBxH–28x22x9cms ACCESSORIES 9126 EN ISO 13485: 2012 + AC: 2012
  • 25.
    DIGIMED COMPUTERISED INTERFERENTIAL THERAPY FEATURES 35Pre-programs condition wise with protocols Cable and electrode checking mode User settable memory Light weight and compact design Easy to operate future upgrade without change in hardware DSP Based circuitry, outputs are in 100% accuracy Large graphic LCD display International standards and specifications Advanced patient safety system PC Interfacefacility(infuture) Cap-sensekeys Builtinrechargeablebattery(optional) The DIGIMED is an advanced interferential therapy equipment in the field of electrotherapy. In the development of the unit simplicity of operation and functionality were the principle consideration. All the available types of current and therapy are clearly displayed on a large LCD screen. The corresponding parameters are easily set with 5 Soft touch keys. Pro-pragrammed memory with treatment applications offers protocols for more than 35 frequently occuring indications and users can store their settings in user memorylocationsandeasilyrecall theirprogramsfortheirpatients. SPECIFICATIONS Carrierfrequency - 2000Hz / 4000Hz Basefrequency - 0-150Hz (1Hz step) Sweep frequency - 0-150Hz (1Hz step) Sweep modulation Programs - 1/1S 1/5, 1/5S 6/6S TherapyModes - FourpoleInterferential o FourpoleVector90 o FourpoleVector45 Twopolepre-modulated Outputcurrent - 0- 100mA Timer - 0 -60mins Mainsvoltage - 90-270V/ 50or60Hz SafetyClass - ClassI,TypeBF(IEC60601-1) Dimensions - LxBxH-30x25x10.5cms Weight - 2.5Kgs TECHNICALDATA HMS Medical Systems #9, 1st Cross Street, New Colony, Porur, Chennai - 600116. Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773 Web : www.hms.co.in email : sales@hms.co.in 9126 EN ISO 13485: 2012 + AC: 2012 ACCESSORIES
  • 26.
    DIGISONIC Advanced and trendsetter Ultrasound therapy from HMS R&D. DIGISONIC is designed indigenously with international standards with incomparable quality. The DIGISONIC comes with 1 MHZ and 3 MHZ outputs. Micro controller based circuitry with large LCD display for viewing all parameters. 30 pre-programs and 20 re-writable user settable memory. Easilyselectablecontinuousand9pulsedmodessofttouchkeysforallfunctions. FEATURES 1 MHZ and 3 MHZ outputs in single transducer Large LCD display 30 Pre-programmes 20 User settable memory Water resistant transducer User friendly Light weight plastic moulded cabinet Cap-sense keys Plastic moulded water resistant transducer SPECIFICATIONS Frequency - 1MHZand3MHZ Therapymodes - Continuous/ Pulsed Pulsesettings/Hz - 9Settings/ 100Hz 2 Outputpower - 0- 3W/cm Timer - 0- 60mins MainsVoltage - 90- 270V/ 50or60Hz Safety Class - Dimensions - L x B x H – 28 x 22 x 9 cms Weight - 2.3 Kgs Class I, Type BF (IEC 60601 -1) TECHNICAL DATA COMPUTERISED 1 & 3 MHZ ULTRASOUND THERAPY HMS Medical Systems #9, 1st Cross Street, New Colony, Porur, Chennai - 600116. Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773 Web : www.hms.co.in email : sales@hms.co.in 9126 EN ISO 13485: 2012 + AC: 2012
  • 27.
    DIGISTIM DIGISTIM is acomputerized stimulator unit with therapeutic,lontoporasis and TENS facility. Treatment mode, treatment time and other parameters are displayed in the LCD. Soft touch membrane keys are used to select the modes and parameters. Digital Display Indicates the output current in mA. In IG mode Rectangular / Triangular pulses can be selectable. SPECIFICATIONS Treatment modes - Iontophorosis, Galvanic, Int.Galvanic,Faradic,Surged Faradic, TENS, TENS Burst INT. GAL Therapeutic - 30 – 300 mSec (1 mSec step) Diagnostic - 01, .03, .3, 1, 3, 10, 30, 100, 300 mSec Pulse type - Square, Triangular FARADIC Freq./ P.width - 50 Hz / 7 mSec Surge ON time - 1 – 10 sec (1 sec step) Surge OFF time - 1 – 6 sec (1 sec step) TENS Frequency - 2 – 250 Hz in (1 Hz step) P.Width - 20–250 sec (1m sec step) Output current - 0 – 50 mA Timer - 0 – 60 mins FEATURES Microcontroller based stimulator cum TENS LCD display for therapy type and treatment time User friendly with soft touch key functions Light weight plastic moulded cabinet Mainsvoltage - 220V/ 50 Hz Safety class - Dimensions - L x B x H – 23 x 20 x 8 cms Weight - 2 Kgs TECHNICALDATA Class I, Type BF (IEC 60601 -1) COMPUTERISED MUSCLE STIMULATOR WITH TENS HMS Medical Systems #9, 1st Cross Street, New Colony, Porur, Chennai - 600116. Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773 Web : www.hms.co.in email : sales@hms.co.in 9126 EN ISO 13485: 2012 + AC: 2012
  • 28.
    DIGISTIM EMS isa specially designed Pocket model Stimulator unit for physiotherapy students and home visit therapists. It has three modes IG, F & SF. IG duration / SF intervals can be varied by single control. Micro-controller basedcircuitryhelpsustomakeitcompactandsleek. Itcanbeoperatedbybattery/mains. SPECIFICATIONS TreatmentModels - IG, F,SF IG - 30–150 mSec. FARADIC Freq./P.width - 50 Hz / 0.7 mSec Surge Duration - 1–6 sec Power Source - 9 V Battery / Adaptor FEATURES Battery/ Mainsoperated Microcontroller based circuitry Handy model DIGISTIM EMS MICRO STIMULATOR - POCKET MODEL First time in INDIA HMS Medical Systems #9, 1st Cross Street, New Colony, Porur, Chennai - 600116. Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773 Web : www.hms.co.in email : sales@hms.co.in 9126 EN ISO 13485: 2012 + AC: 2012
  • 29.
    DIGITENS is anadvanced hand held dual Channel Pocket model TENS in the field of Electrotherapy.The microcontroller based circuitry has six preprogrammed output modes that can be selectable by a soft touch key. It has 15 mins built in timeranditwillbeoperatedbybattery/ mains. FEATURES Sixpreprograms Micro-controller controlled circuitry Battery / Adaptor Built-in 15 min timer Separate intensity control for both channels. DIGITENS SIX PROGRAMMED DUAL CHANNEL TENS HMS Medical Systems #9, 1st Cross Street, New Colony, Porur, Chennai - 600116. Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773 Web : www.hms.co.in email : sales@hms.co.in 9126 EN ISO 13485: 2012 + AC: 2012
  • 30.
    DIGITENS 104 isan advanced micro controller based Four Channel TENS from HMS R & D. Unique design with manual and 20 pre-programs. Used for both fitness and therapeutic purpose. Soft touch keys for selection of programs. Built in batterywith10hrs backupindigenousdesignwithinternationalstandards. SPECIFICATIONS TensFrequency - 2–250Hz(1HzStep) Pulse width - 20 – 250 micro seconds No.of Channels - Four Output mode - Continuous/Pulsed Frequency Sweep - Available Treatment Time - 0 – 60 min Pre-program - 1-15 Pain Relieving Program 16-20 Fitness Program Display - 128 / 64 Graphic LCD Display Power Source - Dual Power (Mains/Battery) FEATURES 4Channel Outputs Micro controller based circuitry Manual Cum preprograms facility Obesity Program Universal Input Built In Re-chargeable battery with 10 hrs Back-up ABS Cabinet-Portable & Light Weight MainsInputVoltage - 90V–270VAC Battery - Maintenance free rechargeable Safety Class - Dimensions - L x B x H – 21 x 22.5 x 6.5 cms Weight - 1.75 Kgs TECHNICALDATA Class I, Type BF (IEC 60601 -1) DIGITENS 104 DIGITENS 104 HMS Medical Systems #9, 1st Cross Street, New Colony, Porur, Chennai - 600116. Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773 Web : www.hms.co.in email : sales@hms.co.in 9126 EN ISO 13485: 2012 + AC: 2012
  • 31.
    DIGITRAC is continuousand intermittent traction unit. It is ideal for both cervical and lumbar traction. It is the first indigenous product of its kind. Built in Micro – controller for accuracy and consistency. Soft touch membrane keys are used to select the parameters. Bar graph display indicates the traction force. Weight and hold time/rest time can be set with 1 unit step. Traction force from 3 kg to 45 kgs (upto 90 kgs with doubler) High quality improved heavy duty D C motor fordurabilityandsmoothfunction. SPECIFICATIONS Max.Wt. - 3-45Kgs(1Kgsteps) (90Kgswithdoubler) Min.Wt. - 0-44 Kgs (1 Kg steps) Hold Time - 1–99 Seconds (1 sec step) Rest Time - 1–99 Seconds (1 sec step) Treatment Time - 1–99 minutes (1 min. step) Input Voltage - 90 – 270 V, 50/60 Hz Safety Class - Dimensions - L x B x H–12 x 11.3 x 11 inches Weight - 8 Kgs TECHNICAL DATA Class I, Type BF (IEC 60601 -1) FEATURES Microcontrollerbased Accurate weight settings Real weight sensing mechanism Wide input Voltage range Soft touch switches Easy to operate Compete with international standards DIGITRAC COMPUTERISED CERVICAL / LUMBER TRACTION HMS Medical Systems #9, 1st Cross Street, New Colony, Porur, Chennai - 600116. Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773 Web : www.hms.co.in email : sales@hms.co.in 9126 EN ISO 13485: 2012 + AC: 2012
  • 32.
    DIGIVAC DIGIVAC is anadvanced Computerised Vacuum therapy unit with continuous and pulsed output. Can be integrated with UNISTIM. DIGIMED,SONOMED andINDOMEDseries. FEATURES Continuous&Pulsed Low Noise & vibration Flexible Output cable & Electrodes Light Weight, User friendly Connect with any Model IFT Bio-Compatible Electrodes Universal Input (90-270V AC) SPECIFICATIONS Vacuum Pressure - 100 to 600 m bar (Continuously Adjustable) Output Mode - Pulsed / Continuous Number of Electrodes - Four Mains Voltage - 90–270 V / 50/60 Hz Dimensions - L x B x H – 30 x 20.5 x 10 cms Weight - 2.2 Kgs TECHNICAL DATA COMPUTERISED VACUUM THERAPY HMS Medical Systems #9, 1st Cross Street, New Colony, Porur, Chennai - 600116. Ph : +91 44 2476 0756, 2476 6576 Telefax : +91 44 2476 3773 Web : www.hms.co.in email : sales@hms.co.in 9126 EN ISO 13485: 2012 + AC: 2012