Designed with your needs in mind, Revolution ACTs helps you improve standards of patient care by providing new levels of image quality. Intelligent technology designed to help you acquire high-quality images using lower doses of radiation, contributing to more accurate diagnoses and lower exposures for patients.
2. • No posterior fossa artifact
• ODM to save dose to eye without image penalty
• Clarity Detector and Imaging chain – no streak artifacts from sharp bone edges
Excellent grey white differentiation
ASIR improves Low Contrast Detectability
40 % reduction in dose
Axial mode : 5mm2/i
Algorithm : Soft/SS50
140 kV
100 mA
Sacn time: 2s
14 rotations
Routine Brain Scan with ASIR
Images courtesy Aaarthi Scans Chenna
3. DSA Circle of Willis
Subtraction Angio
Bone free CT angio for head and neck region
With DSA technqiue
Subtraction image shows well defined vessel delineation
Images courtesy Aaarthi Scans Chenna
4. Helical
140 kV
110 mA
1s, 0.625 mm, Pitch 1:1
Scan time : 19 s
Algorithm: Bone+
ASIR 40 %
IQ Enhance ON
Hi Res IAC
Images courtesy Aaarthi Scans Chenna
5. Axial Mode
Rotation time 1s
140 kV
95 mA
Sub-mm 0.625mm x
2i mode
Algorithm: Bone+
Dose Information Eff Dose = 0.49
mSv
(DLP 35.19 ) *EDLP – ICRP
Publication 102 , Chest factor
0.014
HRCT – Chest with Sub mm Slices
Images courtesy Aaarthi Scans Chenna
6. Helical
120 kV
Auto mA, NI 15
1s, 5 mm, Pitch 1.675
Scan time : 21 s
Algorithm: CHST/SS40
Hi Resolution CECT Chest
70 ml of Omnipaque 300 mgI/dL
30 ml of saline
Images courtesy Aaarthi Scans Chenna
7. Min IP and Bronchogram
Images courtesy Aaarthi Scans Chenna
8. Low dose Pulmonary Angio
Pulmonary Angio thick MIP images
shows thrombus in the R &L
pulmonary arteries
DLP 62, Eff Dose – 0.86 mSv
Images courtesy Aaarthi Scans Chenna
9. Low dose dual phase liver study shows
visualization of hepatic portal
vasculature
Helical 120 kV
Auto mA - 30 to 160 mA
Scan time: 1s,
Algorithm: STD
ASIR : 50%
245 mm Coverage
Scan time 14 s
1.25 mm slices
Pitch 1.675:1
Dose Information Eff Dose = 5.2 mSv
(DLP 351.24) *EDLP – ICRP Publication
102 ,
Abd factor 0.015
Images courtesy Aaarthi Scans Chenna
10. Renal Angio Autobone Xpress
Helical
120 kV
Auto mA
ASIR 40
0.98 s, 1.25 mm, Pitch
1.675:1
Scan time : 1s
Algorithm: CHST
80 ml Omnipaque 300
mgI/dL
3 ml/sec flowrate with inj
Eff Dose = 2.51 mSv
Images courtesy Aaarthi Scans Chenna
11. Hi Res Aortic +
LL Angio
350 mg of Iodine 130 cc
With the flow rate of 3
ml/sec
Using smart prep
technique
Increased LCD
Noise suppression with ASIR
Nice anatomical visualization
Longer coverage
Total DLP 409 for 1200 mm
12. Increased LCD
Noise suppression with ASIR
Nice anatomical visualization
Longer coverage
Peripheral Angio of normal lower
limb vasculature extending distal
end anatomy
Images courtesy Aaarthi Scans Chennai
13. Metal artifact reduction with ASIR
Asir reduces artifacts from metal upto a percentage and
can visualize bone to metal intact margins for post op erative
Evaluation and follow up
Eff Dose = 3.30 mSv
Helical
140 kV
AutomA, NI 18
1 s, 1.25 mm
Pitch 1.375:1
Scan time : 42 s
Coverage 589 mm
Algorithm: Bone
ASIR 80 %
Images courtesy Aaarthi Scans Chenna
14. To know more click here http://www3.gehealthcare.in/en/products/categories/computed-
tomography/revolution-acts/revolution_acts_ex