4. Παραγφγή Παγκοζμίφς
DAL, EIDSVOLL, NORWAY
AARHUS, DENMARK
WAALWIJK, THE NETHERLANDS
LANGENFELD, GERMANY
BOUCTOUCHE, CANADA
WINDISCHBUCH, GERMANY
KANSAS CITY, USA
MADRID, SPAIN
SKINNSKATTEBERG, SWEDEN
HÄSSLEHOLM, SWEDEN
UKMERGE, LITHUANIA
MÜLHEIM AN DER RUHR, GERMANY
BRATISLAVA, SLOVAKIA
MARIBOR, SLOVENIA
MILANO, ITALY
ISTANBUL, TURKEY
DAL, EIDSVOLL, NORWAY
HASSELAGER, DENMARK
BOUCTOUCHE, CANADA
KANSAS CITY, USA
LANGENFELD, GERMANY
WINDISCHBUCH,
GERMANY
MADRID, SPAIN
SKINNSKATTEBERG, SWEDEN
HÄSSLEHOLM, SWEDEN
NEW
UKMERGE, LITHUANIA DELHI, INDIA
HYDERABAD, INDIA
BRATISLAVA, SLOVAKIA
MARIBOR, SLOVENIA
KUALA LUMPUR,
MALAYSIA
MILANO, ITALY
NEW DELHI, INDIA
HYDERABAD, INDIA
Over 200,000 m2 of
production area in 19
factories in 15 countries
KUALA LUMPUR,
MALAYSIA
5. Successful brands with
energy efficient products
Ventilation Products
Air Curtains &
Heating products
Ventilation Products
North America
Heating products for
ventilation systems
Air Handling Units
Air Handling Units
6. Ομάδες προχόνηφν – ολοκληρφμένα ζσζηήμαηα
Αλεκηζηήξεο
Car park
ventilation
Tunnel
ventilation
Fire safety
Απνθαπληζκνο
Αεξόςπθηα
πζηήκαηα
πζηήκαηαΜνλάδεο
Αλάθηεζεο –Κ.Κ.Μ
πζηήκαηα
Οηθηαθνύ Αεξηζκνύ
Αεξηζκόο Πηζηλέο
Αεξνθνπξηηλεο
& Ηι. Θεξκαλζε
Δηαλνκή &
Δηαρείξηζε Αέξα
7. Indoor Air Quality
Balanced Ventilation
Green Ventilation
Demand Ventilation
Energy recovery
Simplify the installer
EC-Vent
10. Most efficient system solution
Balanced ventilation with energy recovery:
Fans run incoming and outgoing air = full air control
+ I.A.Q
Modern control system = demand control
Energy efficient EC-motors = low energy use
The warm indoor air is used to warm the incoming air
Energy Recovery
Filter cleans the incoming air .Health + Comfortable
Clean indoor air is proved to give
better health, performance and environment.
11. Balanced Ventilation - I.A.Q.- Energy recovery
Οικιακές Μονάδες Ανάκηηζης Ενέργειας
Systemair –
Ο ζπλεξγάηεο ζνπ ζην ζρεδηαζκό θαη ζηελ
εθαξκνγή ελόο πιήξεο ζπζηήκαηνο
Οηθηαθνύ αεξηζκνύ –αλάθηεζεο ελέξγεηαο
Apartment building, St. Johann, Austria
12. Balanced Ventilation - I.A.Q.- Energy recovery
Ασηόνομες Μονάδες Ανάκηηζης Αέρα
Για επαγγελμαηική εθαρμογή
Compact Air Handling Units
450 – 15.000 m³/h
Diakoniewerke in Duisburg, Germany
13. Fresh air at home
Nεα ζεηξά Απηόλνκσλ Μνλάδσλ Αλάθηεζεο
Ελέξγεηαο γηα νηθηαθέο εθαξκνγέο από ηε Systemair
16. Οικιακή ζειρά ηης Systemair
Side connected
Rotating
Cross flow
Top connected
Counter
flow
Rotating
Cross
flow
Counter
flow
EC
AC
EC
EC
AC
EC
VR 250 EC
VX 400 E
SAVE VSC 150
VR 400 DC
VR 300 ECV/B
VX 250 TV/P
VM 1
VX 700 E
SAVE VSC 300
VR 400 DCV/B L/R
VX 400 EV L
VM 2
SAVE VSC 500
VR 700 DCV
VX 400 EV R
SAVE VTC 300 R/L
SAVE VTR 150/K R/L
VX 700 EV R
SAVE VTC 700 R/L
SAVE VTR 200/B R/L
VX 700 EV L
VTC Low E
VR 700 DC
SAVE VSR 150
SAVE VSR 300
SAVE VSR 500
SAVE VTR 300 R/L
SAVE VTR 500 R/L
SAVE VTC 200 R/L
38. Building service center Genius,
for energy efficiency homes
Medium for energy transport is
air, because…
● Ventilation is essential
● Heating demand decreases
more and more
● Cooling demand increases
Separate water distribution
system for heating no longer
necessary!
39. Future of building technology?
One device for everything:
Heating
Cooling
Domestic Hot Water
Ventilation
40. Combi-unit Genius
Ventilation Module
●
Rotating heat exchanger with humidity recovery
●
Heating and cooling through supply air ducts (recirculation
air)
Heat pump module
●
Reversible air to air and air to water heat pump for heating,
cooling and hot water
●
Steplessly controlled compressor to modulate the power
exactly to the need of heating and cooling energy
Hot water module
●
Hot water production (150 l) parallel to heating and cooling
41. Technical data
•
•
•
•
•
•
•
•
•
•
•
•
Air flow in normal mode: 180m³/h (100Pa).
Heat recovery: up to 85%.
Heating capacity: max.6 kW;
Cooling capacity: max.4 kW.
PTC-elements: each 500 W.
Heating coil DHW: 3 kW
Max. airflow heating/cooling (incl. secondary air): 550
m³/h (100Pa).
Storage content:150l.
Filter: Outdoor air F7; Extract air G4; Secondary air G4.
Fans: EC-Motors, max. power input 80W.
Compressor: stepless, reversible via 4-way-valve, max.
power input1,8kW.
Refrigerant: R-410 A
42. Userfriendly and modern
User can adjust the unit according to his needs via:
Control panel (SCP)
PC (direct connected or via Internet)
Mobile (APP)
A change of the setting is automatically valid for all functions and must be
set only once for the whole building service. Everything is working together
under one control system.
43. Systemair Save Vent Comfort
Good - healthy indoor environment
Residential energy heat recovery systems
Picture of yourself
43
Defrost mode Mode RH indoorsDescription1 Minimum <20% Dry areas, such as warehouse buildings with few people or industrial buildings that don’t use water in their production process.2 Low 30%-40% Office buildings.3 (standard) Medium 40%-60% Apartments or houses with normal humidity.4 High 60%-80% Apartments or houses with high humidity.5 Extremely high >80% Buildings with very high humidity level.