Case Study
Acoustic Enclosure for a `Horizontal Balancing Machine'
Process Details: Acoustic enclosure for a `Horizontal Balancing Machine' for the worlds leading aero engine
based aerospace manufacturer.
Scope of Work: To design, manufacture, deliver, install and commission the required acoustic enclosure, this
being of approximate overall dimensions 6.4m long x 3.2m wide x 2.5m high.
Design Considerations: -
• The enclosure to be fit for purpose in providing a safe working environment for operations and maintenance
personnel.
• The unit to be supplied in two pre-assembled halves for positioning about the existing balancing machine and
associated ancillary / auxiliary equipment.
• When fully assembled, the enclosure to provide the desired access in the form of bi-parting pneumatically
operated, horizontally sliding doors and canopy, giving unhindered access to both the enclosure front and roof
over an area approximately 3.5m long, to facilitate operator entry/egress, and the loading and unloading of
tooling via an overhead shop crane.
• Surface mounted floor track arrangement with external rampart and internal aluminium tread-plate decking,
offering personnel safe passage in and out of the enclosure without encountering an unacceptable trip
hazard.
• Acoustically insulated vision panels that provide the necessary resistance to internal damage by projectiles,
flying debris etc.
• Inclined vision panel arrangement to further enhance the operators overview of the balancing process.
• The provision of the necessary electrical fitments to facilitate adequate high frequency lighting suitable for
rotating machinery.
• Integration and mechanical installation of the end users factory standard door interlock equipment.
Acoustic Performance: Based solely on a maximum figure of 95dB(A) at 1 metre, the proposed construction
rated at 25db satisfied the end users requirements.
Customer Comment: We wish to convey a big thank you for a job well done by all parties concerned. Thank
you all for your dedication and commitment to this project.
Acoustic Applications is the trading name of Xtron Systems Limited
Unit 8, Caldervale Road, Horbury Junction Industrial Estate, Wakefield, West Yorkshire, WF4 5ER.
Telephone No. +44 (0) 1924 26 21 65 Facsimile No. +44 (0) 1924 26 48 17
England & Wales Company Registration No. 06986821 - VAT Registration No. GB 981 1986 80

More Related Content

What's hot

Possibilities of vacuum lifting with fezer
Possibilities of vacuum lifting with fezerPossibilities of vacuum lifting with fezer
Possibilities of vacuum lifting with fezerYES MACHINERY
 
Lifting and manipulation
Lifting and manipulationLifting and manipulation
Lifting and manipulationYES MACHINERY
 
Fiber Cable Ducting System Compare
Fiber Cable Ducting System CompareFiber Cable Ducting System Compare
Fiber Cable Ducting System CompareJack_Han
 
Airius suspended-series-models-10-15-25-data-sheet-2019
Airius suspended-series-models-10-15-25-data-sheet-2019Airius suspended-series-models-10-15-25-data-sheet-2019
Airius suspended-series-models-10-15-25-data-sheet-2019Airius Europe Ltd
 
Return conveyor-loopteq-o-300-en
Return conveyor-loopteq-o-300-enReturn conveyor-loopteq-o-300-en
Return conveyor-loopteq-o-300-enAmirStern2
 

What's hot (8)

Possibilities of vacuum lifting with fezer
Possibilities of vacuum lifting with fezerPossibilities of vacuum lifting with fezer
Possibilities of vacuum lifting with fezer
 
16_400_ProFlexClassicCutUp
16_400_ProFlexClassicCutUp16_400_ProFlexClassicCutUp
16_400_ProFlexClassicCutUp
 
Bosch/Doboy B-550
Bosch/Doboy B-550Bosch/Doboy B-550
Bosch/Doboy B-550
 
Lifting and manipulation
Lifting and manipulationLifting and manipulation
Lifting and manipulation
 
Fiber Cable Ducting System Compare
Fiber Cable Ducting System CompareFiber Cable Ducting System Compare
Fiber Cable Ducting System Compare
 
FLCL_Ranipet_Profile
FLCL_Ranipet_ProfileFLCL_Ranipet_Profile
FLCL_Ranipet_Profile
 
Airius suspended-series-models-10-15-25-data-sheet-2019
Airius suspended-series-models-10-15-25-data-sheet-2019Airius suspended-series-models-10-15-25-data-sheet-2019
Airius suspended-series-models-10-15-25-data-sheet-2019
 
Return conveyor-loopteq-o-300-en
Return conveyor-loopteq-o-300-enReturn conveyor-loopteq-o-300-en
Return conveyor-loopteq-o-300-en
 

Viewers also liked (8)

Shia and belief
Shia and beliefShia and belief
Shia and belief
 
Johnathan Cody Massey new resume
Johnathan Cody Massey new resumeJohnathan Cody Massey new resume
Johnathan Cody Massey new resume
 
Christmas Bazaar at Nicosia, Cyprus
Christmas Bazaar at Nicosia, CyprusChristmas Bazaar at Nicosia, Cyprus
Christmas Bazaar at Nicosia, Cyprus
 
Proyecto
ProyectoProyecto
Proyecto
 
Recurso educativo
Recurso educativoRecurso educativo
Recurso educativo
 
Matriz dofa2
Matriz dofa2Matriz dofa2
Matriz dofa2
 
Bulgarian School in Nicosia - Flyer p.2
Bulgarian School in Nicosia - Flyer p.2Bulgarian School in Nicosia - Flyer p.2
Bulgarian School in Nicosia - Flyer p.2
 
Computer1
Computer1Computer1
Computer1
 

Similar to C5169 Case Study - Acoustic enclosure for a Horizontal Balancing Machine

C4959 Case Study - Vac Pump Enclosure
C4959 Case Study - Vac Pump EnclosureC4959 Case Study - Vac Pump Enclosure
C4959 Case Study - Vac Pump EnclosureChristian Senior
 
C4494 Case Study - Caster Control Complex
C4494 Case Study - Caster Control ComplexC4494 Case Study - Caster Control Complex
C4494 Case Study - Caster Control ComplexChristian Senior
 
C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...
C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...
C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...Christian Senior
 
C4706 Case Study - Acoustic Screen with Chevron Louvres
C4706 Case Study - Acoustic Screen with Chevron LouvresC4706 Case Study - Acoustic Screen with Chevron Louvres
C4706 Case Study - Acoustic Screen with Chevron LouvresChristian Senior
 
C4950 Case Study #1 - Mess Facilities for Furnace Control Rooms
C4950 Case Study #1 - Mess Facilities for Furnace Control RoomsC4950 Case Study #1 - Mess Facilities for Furnace Control Rooms
C4950 Case Study #1 - Mess Facilities for Furnace Control RoomsChristian Senior
 
C5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying Process
C5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying ProcessC5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying Process
C5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying ProcessChristian Senior
 
C4359 Case Study - Noise Barrier Screening
C4359 Case Study - Noise Barrier ScreeningC4359 Case Study - Noise Barrier Screening
C4359 Case Study - Noise Barrier ScreeningChristian Senior
 
Acoustic Enclosure - Ecotone Systems Pvt Ltd
Acoustic Enclosure - Ecotone Systems Pvt LtdAcoustic Enclosure - Ecotone Systems Pvt Ltd
Acoustic Enclosure - Ecotone Systems Pvt LtdEcotone Systems Pvt Ltd
 
Best practice guidance on choosing site lighting, supplied in conjunction wit...
Best practice guidance on choosing site lighting, supplied in conjunction wit...Best practice guidance on choosing site lighting, supplied in conjunction wit...
Best practice guidance on choosing site lighting, supplied in conjunction wit...IQ_UK
 
FanAir Sound Enclosure Brochure
FanAir Sound Enclosure BrochureFanAir Sound Enclosure Brochure
FanAir Sound Enclosure Brochurewww.FanAir.com
 
Abc heavy engineering capability statement
Abc heavy engineering capability statement Abc heavy engineering capability statement
Abc heavy engineering capability statement Brett Oar
 
Modular operation theater by workspace solutions
Modular operation theater by workspace solutionsModular operation theater by workspace solutions
Modular operation theater by workspace solutionsAbhishek vyas
 
Micro-speaker Assembly Application
Micro-speaker Assembly ApplicationMicro-speaker Assembly Application
Micro-speaker Assembly ApplicationOmniCure
 
GTM Blow Off Cabinets Best Practice
GTM Blow Off Cabinets Best PracticeGTM Blow Off Cabinets Best Practice
GTM Blow Off Cabinets Best PracticeAlphaBetaTech
 
Performix System - High Performance 300mm EFEM
Performix System - High Performance 300mm EFEMPerformix System - High Performance 300mm EFEM
Performix System - High Performance 300mm EFEMkensington labs
 
Parker Tube Fittings - Ermeto Fittings
Parker Tube Fittings - Ermeto FittingsParker Tube Fittings - Ermeto Fittings
Parker Tube Fittings - Ermeto FittingsArvihitechco
 

Similar to C5169 Case Study - Acoustic enclosure for a Horizontal Balancing Machine (20)

C4959 Case Study - Vac Pump Enclosure
C4959 Case Study - Vac Pump EnclosureC4959 Case Study - Vac Pump Enclosure
C4959 Case Study - Vac Pump Enclosure
 
C4494 Case Study - Caster Control Complex
C4494 Case Study - Caster Control ComplexC4494 Case Study - Caster Control Complex
C4494 Case Study - Caster Control Complex
 
C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...
C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...
C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...
 
C4706 Case Study - Acoustic Screen with Chevron Louvres
C4706 Case Study - Acoustic Screen with Chevron LouvresC4706 Case Study - Acoustic Screen with Chevron Louvres
C4706 Case Study - Acoustic Screen with Chevron Louvres
 
C4950 Case Study #1 - Mess Facilities for Furnace Control Rooms
C4950 Case Study #1 - Mess Facilities for Furnace Control RoomsC4950 Case Study #1 - Mess Facilities for Furnace Control Rooms
C4950 Case Study #1 - Mess Facilities for Furnace Control Rooms
 
C5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying Process
C5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying ProcessC5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying Process
C5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying Process
 
C4359 Case Study - Noise Barrier Screening
C4359 Case Study - Noise Barrier ScreeningC4359 Case Study - Noise Barrier Screening
C4359 Case Study - Noise Barrier Screening
 
Acoustic Enclosure
Acoustic EnclosureAcoustic Enclosure
Acoustic Enclosure
 
Acoustic Enclosure - Ecotone Systems Pvt Ltd
Acoustic Enclosure - Ecotone Systems Pvt LtdAcoustic Enclosure - Ecotone Systems Pvt Ltd
Acoustic Enclosure - Ecotone Systems Pvt Ltd
 
Best practice guidance on choosing site lighting, supplied in conjunction wit...
Best practice guidance on choosing site lighting, supplied in conjunction wit...Best practice guidance on choosing site lighting, supplied in conjunction wit...
Best practice guidance on choosing site lighting, supplied in conjunction wit...
 
FanAir Sound Enclosure Brochure
FanAir Sound Enclosure BrochureFanAir Sound Enclosure Brochure
FanAir Sound Enclosure Brochure
 
Abc heavy engineering capability statement
Abc heavy engineering capability statement Abc heavy engineering capability statement
Abc heavy engineering capability statement
 
Modular operation theater by workspace solutions
Modular operation theater by workspace solutionsModular operation theater by workspace solutions
Modular operation theater by workspace solutions
 
Micro-speaker Assembly Application
Micro-speaker Assembly ApplicationMicro-speaker Assembly Application
Micro-speaker Assembly Application
 
GTM Blow Off Cabinets Best Practice
GTM Blow Off Cabinets Best PracticeGTM Blow Off Cabinets Best Practice
GTM Blow Off Cabinets Best Practice
 
Accurate Group Presentation
Accurate Group  PresentationAccurate Group  Presentation
Accurate Group Presentation
 
Performix System - High Performance 300mm EFEM
Performix System - High Performance 300mm EFEMPerformix System - High Performance 300mm EFEM
Performix System - High Performance 300mm EFEM
 
GTC EMS Bro 12-15
GTC EMS Bro 12-15GTC EMS Bro 12-15
GTC EMS Bro 12-15
 
Digital edition may 2020
Digital edition may 2020Digital edition may 2020
Digital edition may 2020
 
Parker Tube Fittings - Ermeto Fittings
Parker Tube Fittings - Ermeto FittingsParker Tube Fittings - Ermeto Fittings
Parker Tube Fittings - Ermeto Fittings
 

C5169 Case Study - Acoustic enclosure for a Horizontal Balancing Machine

  • 1. Contact us for your industrial noise solutions. +44 (0) 1924 26 21 65 sales@acousticapplications.co.uk Case Study Acoustic Enclosure for a `Horizontal Balancing Machine' Process Details: Acoustic enclosure for a `Horizontal Balancing Machine' for the worlds leading aero engine based aerospace manufacturer. Scope of Work: To design, manufacture, deliver, install and commission the required acoustic enclosure, this being of approximate overall dimensions 6.4m long x 3.2m wide x 2.5m high. Design Considerations: - • The enclosure to be fit for purpose in providing a safe working environment for operations and maintenance personnel. • The unit to be supplied in two pre-assembled halves for positioning about the existing balancing machine and associated ancillary / auxiliary equipment. • When fully assembled, the enclosure to provide the desired access in the form of bi-parting pneumatically operated, horizontally sliding doors and canopy, giving unhindered access to both the enclosure front and roof over an area approximately 3.5m long, to facilitate operator entry/egress, and the loading and unloading of tooling via an overhead shop crane. • Surface mounted floor track arrangement with external rampart and internal aluminium tread-plate decking, offering personnel safe passage in and out of the enclosure without encountering an unacceptable trip hazard. • Acoustically insulated vision panels that provide the necessary resistance to internal damage by projectiles, flying debris etc. • Inclined vision panel arrangement to further enhance the operators overview of the balancing process. • The provision of the necessary electrical fitments to facilitate adequate high frequency lighting suitable for rotating machinery. • Integration and mechanical installation of the end users factory standard door interlock equipment. Acoustic Performance: Based solely on a maximum figure of 95dB(A) at 1 metre, the proposed construction rated at 25db satisfied the end users requirements. Customer Comment: We wish to convey a big thank you for a job well done by all parties concerned. Thank you all for your dedication and commitment to this project. Acoustic Applications is the trading name of Xtron Systems Limited Unit 8, Caldervale Road, Horbury Junction Industrial Estate, Wakefield, West Yorkshire, WF4 5ER. Telephone No. +44 (0) 1924 26 21 65 Facsimile No. +44 (0) 1924 26 48 17 England & Wales Company Registration No. 06986821 - VAT Registration No. GB 981 1986 80