APPLICATION OVERVIEW
75F Outside Air Optimization (OAO) is an application that
combines hardware, software and real-time weather
data providing advanced sequences of operation from
rooftop economizers to built-up air handlers in a wide
range of commercial buildings. Facility managers who
want to maximize efficiency, occupant comfort and
indoor air quality (IAQ) should install OAO on all outside
air applications. Customers can also add OAO to maintain
pressure inside a building.
OAO’s three primary benefits are Improved Efficiency,
Comfort and IAQ, something it accomplishes thanks to
two main application functions: Economizing and Demand
Control Ventilation (DCV).
75F® Outside Air Optimization™
Save energy, provide comfort and improve indoor air quality
FEATURES
• Works with Variable Air Volume (VAV) and Dynamic 	 	
Airflow Balancing™ (DAB) to provide advanced 			
economizer controls to RTUs and AHUs
• Monitors and analyzes return air CO2 for DCV
• Web-based, aggregated weather feeds for outside air 		
temperature and humidity
• Backup temperature probe for outside air
• Return and outside air damper controls
• 2-stage exhaust fan control
• Mixed Air Temperature (MAT) and humidity sensing with	
a minimum temperature safety feature
888.590.8995 | support@75f.io | www.75f.io
IMPROVED EFFICIENCY
The efficiency of outside air (OA) applications is dramatically improved by employing demand control ventilation (DCV) and
comparative enthalpy economy sequences. 75F OAO hardware includes a CO2 sensor installed in the air handler’s return air
(RA) duct to determine IAQ and derived occupancy. The OA is modulated with a 0/2-10V actuator controlling the OA and RA
dampers. Conditioning OA is inefficient when temperature and humidity are far from desired indoor levels – however, OAO
lets a precise amount of air in to balance IAQ and comfort in a space.
ASHRAE Standard 62.1 provides direction for the correct ventilation rates of occupied spaces. When occupancy is unknown,
the standard calls for assuming the worst case — maximum occupancy — to set the minimum position of the OA damper. In
reality, most spaces are not occupied at maximum ,and the result is that most indoor spaces are over-ventilated at the cost
of much greater mechanical conditioning and energy cost. Using DCV, OAO from 75F delivers an ASHRAE-approved method
to derive occupancy, allowing for adjustments of the OA damper according to CO2 instead of assuming the worst case. The
result is energy savings during low occupancy and improved IAQ during high occupancy.
OAO also allows buildings to maximize “free cooling”, the basic function of an economizer. A basic economizer — the type
typically installed in package units — measures outside air dry-bulb temperature to determine if OA is at or below a certain
temperature, usually about 55°F. Based on historical weather data, the basic economizer assumes a relative humidity value
to calculate an assumed enthalpy (a measure of both temperature and humidity), and will then open the OA damper to cool
indoor spaces.
Because the basic economizer is assuming enthalpy based on the dry-bulb temperature and historical humidity levels for
a weather zone, the formula is conservative and only provides free cooling for fraction of the available time. Comparative
enthalpy economy from 75F’s OAO system is a far superior method to obtain the maximum amount of free cooling because
it uses real-time outside enthalpy data and compares it with real-time indoor enthalpy data to lower energy costs and
improve efficiency through free cooling. Not only does the system compare the two enthalpy values, it also calculates the
final enthalpy of supply air when heated up to indoor levels using psychrometric charts to ensure the resulting air meets a
desired target. The result is typically three times more free cooling than a basic economizer and much better comfort for
guests and occupants.
COMFORT
As explained in the previous section, most basic economizers on the market today are typically set to let in OA only when it
is 55°F and lower (usually a lower limit is also set). A downside of this is that during winter months, when free cooling is used
to bring down the temperature of warmer interior zones, this 55°F or colder air can cause occupant complaints. Any time
supply air is noticeably hotter or colder than the indoor environment, comfort is reduced.
• Proprietary algorithms reduce energy use by 20-30%
with OAO alone. Machine learning optimizes energy
efficiency, comfort, and IAQ even further.
• Enhanced features compared to traditional zone controls:
	 – Energy savings
	 – Improved Comfort
	 – Optimized IAQ
	 – Easy scheduling
	 – Remote configuration
	 – Fault detection and diagnostics
ADVANTAGES
• Outside Air Optimization (OAO) from 75F uses web-
based, aggregated weather feeds specific to each building.
• OAO is simple to install and works out of the box with no
programming required.
• Wireless design eliminates invasive or complicated installs.
• Advanced controls allow the use of OAO on everything
from simple rooftop units to sophisticated air handling units.
• Fully integrates with 75F Facilisight portal and mobile app.
888.590.8995 | support@75f.io | www.75f.io
OAO from 75F continuously measures the temperature
and humidity in all occupied spaces and very accurately
calculates loads to determine what the best supply air
temperature should be. During free cooling periods, 75F
will partially open the OA damper to achieve an MAT that
is optimal for the load conditions and which will maintain
an optimal experience for the occupant. This results in
improved comfort, as well as efficiency.
IAQ
The 75F OAO kit includes a CO2 sensor in the return duct
of the air handler to measure the average IAQ of the
building’s envelope. When occupancy is high, or when
external factors are deteriorating IAQ, 75F will modulate
the OA damper proportionally with IAQ values to ventilate
with fresh OA to achieve minimum values. Other 75F IAQ
sensors such as CO and NO2 can be added to this sequence
for spaces like parking garages or other applications. The
75F OAO sequence includes a control point to activate
an exhaust fan based on how much OA is entering the
envelope.
ECONOMIZING
Economizers are a feature of HVAC systems which use cold OA to provide free cooling in a space. Outdoor Air Economizing
from 75F uses forecasts and temperature data to predictively determine when OA is suitable for free cooling. When OA
temperature and humidity is not sufficient to completely cool zones or rooms, then the 75F system utilizes this air instead of
the return air coming from building as a prefeed to mechanical cooling. This applies only to cooling modes.
Economizer functions are typically based on two parameters, temperature and humidity. Simpler systems only use
temperature for this function, whereas more sophisticated systems will use both temperature and humidity. Systems based
on temperature and humidity are called enthalpy economizers, as they use the enthalpy of both the outside air and the
indoor air to make constant decisions on whether to bring in OA for free cooling.
Use averageZoneTemperature and averageZoneHumidity to compute insideAirEnthalpy
Use weatherOutsideTemperature and weatherOutsideHumidity to determine the outsideAirEnthalpy
If
outsideAirEnthalpy + enthalpyDuctCompensationOffset < insideAirEnthalpy
then
economizingAvailable = true
If a building needs cooling, the 75F operating system, Renatus, uses systemCoolingLoopOutput to open the OA damper and
will record this change as free cooling used. If any of the staged RTU profiles are used, then OAO forms the first stage of the
cooling capacity. For example, where a 3-stage RTU is configured, when economizing is available it will appear as if there are
4 stages to the RTU and the economizing loop (OAO) will map to the first 25% of the systemCoolingLoopOutput.
If a fully modulating RTU is used, then the economizingLoopOutput maps to the first economizingToMainCoolingLoopMap
as a percentage of the cooling loop.
MIXED AIR TEMPERATURE (MAT)
SAFETY REGULATIONS
If the MAT is above OutsideDamperMixedAirTarget,
then the system will start progressively closing the
damper until outsideDamperMixedAirMinimum.
This is true for both DCV and economizing systems.
Simply put, for DCV heating mode, this prevents
condensation of flue gases when heating is on, and
avoids corrosion due to the acidity that may be present
in that condensation.
For DCV or economizing in cooling mode, this will
cause super cold air to be supplied, which can lower
the comfort of occupants and is not desirable.
UNDERSTANDING: HUMIDITY & ENTHALPY
As water evaporates, it converts into water vapor and cools—this is why sweat or misting systems are so effective. The
water vapor in the air stores a huge amount of energy. Enthalpy determines the total amount of energy in the air and is
based on both humidity and temperature. While there is no simple math to determine enthalpy, a psychometric chart
can be used to discover how much energy is stored in the air. This graphical representation calculates thermodynamic
properties like dry-bulb temperature, wet-bulb temperature, humidity, enthalpy and air density.
For example, a building has an inside temperature of 72°F with 40% humidity. Let’s also assume that in this example the
air outside is significantly cooler at 60°F with 65% humidity. To find enthalpy using a psychometric chart, like the one found
below, you first find the temperature reading on the bottom horizontal axis and its associated vertical line, reading left to
right. Then, you identify the humidity percentage on the sloping diagonal lines which increase with temperature. Trace
both your temperature vertical line and the humidity slope until they meet. Once you have located this point, trace the
corresponding diagonal enthalpy line to determine your enthalpy reading.
In the chart below we can see that 60°F with 65% humidity has less enthalpy than 72°F with 40% humidity. Therefore,
according to the chart, the outdoor enthalpy is less than the indoor enthalpy, and bringing in fresh air to cool the building
(instead of mechanical cooling) makes sense.
With OAO from 75F, temperature and humidity data is fed into the cloud and referenced against outdoor forecast
predictions over time by 75F’s cloud-based AI, Athena. Over one million data points per 50,000sq. ft. of space, and tens of
thousands of separate enthalpy decisions are made each day by the 75F OAO application.
This psychometric chart indicates that air which is 72˚F with 40%
humidity has more energy than air which is 60˚F with 65% humidity.
This psychometric chart indicates that air which is 60˚F with 65%
humidity will end up with 43% humidity when heated to 72˚F.
DCV
The system uses CO2 levels to determine the amount of OA that should be brought in to maintain the optimal IAQ. If CO2
readings in a space are below threshold, then DCV has no affect. If CO2 is above threshold, the 75F system will automatically
and proportionately open the OA damper. In other words, DCV essentially sets the minimum damper opening level at any
given time and is calculated based on either the return air CO2 or individual spaces using a Trim and Respond system. This
applies to both cooling and heating in ‘Occupied Mode’.
If there are no CO2 sensors in the space, then the system uses the return air CO2 sensor to provide an average CO2 level to
control OA dampers appropriately. Generally, CO2 levels are within the threshold level for most buildings the majority of the
time. In this case, the system uses outsideDamperMinOpen while above threshold levels and the system is opened to allow
more fresh air in.
888.590.8995 | support@75f.io | www.75f.io
FINAL DAMPER DRIVE
The outside damper output signal will
modulate between outsideDamperAtMinDrive
and outsideDamperAtMaxDrive as the
oaoFinalLoopOutput changes from 0% to 100%
depending on the conditions.
The return air damper works in opposition to the
outside air damper and is calculated as follows:
returnAirFinalOutput = 100 -
outsideAirFinalLoopOutput
CONNECTIVITY
In this setup,
• Analog-in1 connects to return air CO2 sensor
• Analog-in2 connects to RTU current transformer
• Th-in1 connects to Outside Air Temperature
• Th-in2 connects to Supply Air Temperature
• One Wire sensor bus connects to Duct Temperature 	
and Humidity sensor for Mixed Air Temperature and	
Humidity
• Analog-out1 connects to Outside Air Damper
• Analog-out2 connects to Return Air Damper
• Relay-1 connects to exhaust fan stage 1
• Relay-2 connects to exhaust fan stage 2
888.590.8995 | support@75f.io | www.75f.io
KIT OPTIONS
CO2 Sensor
TYPE PRODUCT NAME COMPONENTS
Standard Outside Air Optimization Kit Smart Node, CO2, DS, CT, SAT, OAT
Airflow Temperature
Sensor
COMPONENTS OF OAO
75F Outside Air Optimization includes the 75F Facilisight & Occupant App, a 75F Smart Node, and a 75F Central Control
Unit – plus, one 75F Duct Temperature and Humidity Sensor, and a range of external sensors.
75F® Duct Sensor™
75F® Smart Node™
75® Facilisight™ & Occupant App™
Current Switch & Sensor
ADDERS
• Smart Differential Pressure Sensor Kit, with Smart Node, 24V AC Power Supply (#3510)
• NO2 sensor
• CO2 sensor
INCLUDED
Outdoor Air Thermistor
V1.0 May 6, 2020

More Related Content

Similar to 75F Outside Air Optimization and Economizer Control

General Sales Brochure 2016
General Sales Brochure 2016General Sales Brochure 2016
General Sales Brochure 2016
Emma Beresford
 
General Sales Brochure 2016
General Sales Brochure 2016General Sales Brochure 2016
General Sales Brochure 2016
Alan Beresford
 
EcoCooling IT Sales Manual
EcoCooling IT Sales ManualEcoCooling IT Sales Manual
EcoCooling IT Sales Manual
Alan Beresford
 

Similar to 75F Outside Air Optimization and Economizer Control (20)

General Sales Brochure 2016
General Sales Brochure 2016General Sales Brochure 2016
General Sales Brochure 2016
 
General Sales Brochure 2016
General Sales Brochure 2016General Sales Brochure 2016
General Sales Brochure 2016
 
Review of Design of Air Conditioning System for Commercial and Domestic Appli...
Review of Design of Air Conditioning System for Commercial and Domestic Appli...Review of Design of Air Conditioning System for Commercial and Domestic Appli...
Review of Design of Air Conditioning System for Commercial and Domestic Appli...
 
EcoCooling IT Sales Manual
EcoCooling IT Sales ManualEcoCooling IT Sales Manual
EcoCooling IT Sales Manual
 
Gard analytics DOE energy modeling
Gard analytics DOE energy modelingGard analytics DOE energy modeling
Gard analytics DOE energy modeling
 
Appa
AppaAppa
Appa
 
Hvac
HvacHvac
Hvac
 
How do i optimize industrial refrigeration system
How do i optimize industrial refrigeration systemHow do i optimize industrial refrigeration system
How do i optimize industrial refrigeration system
 
Energy Efficiency in Offices
Energy Efficiency in OfficesEnergy Efficiency in Offices
Energy Efficiency in Offices
 
Maximizing energy efficiency in hotel HVAC systems: An energy modelling appro...
Maximizing energy efficiency in hotel HVAC systems: An energy modelling appro...Maximizing energy efficiency in hotel HVAC systems: An energy modelling appro...
Maximizing energy efficiency in hotel HVAC systems: An energy modelling appro...
 
Techfest
TechfestTechfest
Techfest
 
BUILDING SERVICES: BAS
BUILDING SERVICES: BASBUILDING SERVICES: BAS
BUILDING SERVICES: BAS
 
Air conditioning system
Air conditioning system Air conditioning system
Air conditioning system
 
Project on HVACR
Project on HVACRProject on HVACR
Project on HVACR
 
Saving energy with cooling towers
Saving energy with cooling towersSaving energy with cooling towers
Saving energy with cooling towers
 
Overview and Maintenanaces of HVAC system
Overview and Maintenanaces of HVAC system Overview and Maintenanaces of HVAC system
Overview and Maintenanaces of HVAC system
 
Centralized AC System- S Menon & S Dayakar
Centralized AC System-  S Menon & S DayakarCentralized AC System-  S Menon & S Dayakar
Centralized AC System- S Menon & S Dayakar
 
Overview and Maintenanaces of HVAC system
Overview and Maintenanaces of HVAC system Overview and Maintenanaces of HVAC system
Overview and Maintenanaces of HVAC system
 
Central ac system
Central ac system Central ac system
Central ac system
 
Aircondition energy saver
Aircondition energy saverAircondition energy saver
Aircondition energy saver
 

Recently uploaded

Cytotec 200 mcg in doha [+966572737505 ] buy abortion pills
Cytotec 200 mcg in doha [+966572737505 ] buy abortion pillsCytotec 200 mcg in doha [+966572737505 ] buy abortion pills
Cytotec 200 mcg in doha [+966572737505 ] buy abortion pills
samsungultra782445
 
如何办理(USYD毕业证书)悉尼大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(USYD毕业证书)悉尼大学毕业证成绩单本科硕士学位证留信学历认证如何办理(USYD毕业证书)悉尼大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(USYD毕业证书)悉尼大学毕业证成绩单本科硕士学位证留信学历认证
mestb
 
如何办理(AUT毕业证书)奥克兰理工大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(AUT毕业证书)奥克兰理工大学毕业证成绩单本科硕士学位证留信学历认证如何办理(AUT毕业证书)奥克兰理工大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(AUT毕业证书)奥克兰理工大学毕业证成绩单本科硕士学位证留信学历认证
mestb
 
如何办理(SUT毕业证书)斯威本科技大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(SUT毕业证书)斯威本科技大学毕业证成绩单本科硕士学位证留信学历认证如何办理(SUT毕业证书)斯威本科技大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(SUT毕业证书)斯威本科技大学毕业证成绩单本科硕士学位证留信学历认证
mestb
 
办理(uw学位证书)美国华盛顿大学毕业证续费收据一模一样
办理(uw学位证书)美国华盛顿大学毕业证续费收据一模一样办理(uw学位证书)美国华盛顿大学毕业证续费收据一模一样
办理(uw学位证书)美国华盛顿大学毕业证续费收据一模一样
vwymvu
 
[[Jeddah]] IN RIYADH +2773-7758557]] Abortion pills in Jeddah Cytotec in Riya...
[[Jeddah]] IN RIYADH +2773-7758557]] Abortion pills in Jeddah Cytotec in Riya...[[Jeddah]] IN RIYADH +2773-7758557]] Abortion pills in Jeddah Cytotec in Riya...
[[Jeddah]] IN RIYADH +2773-7758557]] Abortion pills in Jeddah Cytotec in Riya...
daisycvs
 
Abortion Clinic in Jeddah +966572737505 buy cytotec pills
Abortion Clinic in Jeddah +966572737505 buy cytotec pillsAbortion Clinic in Jeddah +966572737505 buy cytotec pills
Abortion Clinic in Jeddah +966572737505 buy cytotec pills
Abortion pills in Riyadh +966572737505 get cytotec
 
如何办理(OP毕业证书)奥塔哥理工学院毕业证成绩单本科硕士学位证留信学历认证
如何办理(OP毕业证书)奥塔哥理工学院毕业证成绩单本科硕士学位证留信学历认证如何办理(OP毕业证书)奥塔哥理工学院毕业证成绩单本科硕士学位证留信学历认证
如何办理(OP毕业证书)奥塔哥理工学院毕业证成绩单本科硕士学位证留信学历认证
mestb
 
Abortion pills in Jeddah Saudi Arabia! +966572737505 Where to buy cytotec
Abortion pills in Jeddah Saudi Arabia! +966572737505 Where to buy cytotecAbortion pills in Jeddah Saudi Arabia! +966572737505 Where to buy cytotec
Abortion pills in Jeddah Saudi Arabia! +966572737505 Where to buy cytotec
Abortion pills in Riyadh +966572737505 get cytotec
 
Vibration of Continuous Systems.pjjjjjjjjptx
Vibration of Continuous Systems.pjjjjjjjjptxVibration of Continuous Systems.pjjjjjjjjptx
Vibration of Continuous Systems.pjjjjjjjjptx
joshuaclack73
 
如何办理(UVic毕业证书)维多利亚大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(UVic毕业证书)维多利亚大学毕业证成绩单本科硕士学位证留信学历认证如何办理(UVic毕业证书)维多利亚大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(UVic毕业证书)维多利亚大学毕业证成绩单本科硕士学位证留信学历认证
mestb
 
Buy best abortion pills Doha [+966572737505 | Planned cytotec Qatar
Buy best abortion pills Doha [+966572737505 | Planned cytotec QatarBuy best abortion pills Doha [+966572737505 | Planned cytotec Qatar
Buy best abortion pills Doha [+966572737505 | Planned cytotec Qatar
samsungultra782445
 
Balancing of rotating bodies questions.pptx
Balancing of rotating bodies questions.pptxBalancing of rotating bodies questions.pptx
Balancing of rotating bodies questions.pptx
joshuaclack73
 
Top^Clinic Soweto ^%[+27838792658_termination in florida_Safe*Abortion Pills ...
Top^Clinic Soweto ^%[+27838792658_termination in florida_Safe*Abortion Pills ...Top^Clinic Soweto ^%[+27838792658_termination in florida_Safe*Abortion Pills ...
Top^Clinic Soweto ^%[+27838792658_termination in florida_Safe*Abortion Pills ...
drjose256
 
Abortion pills in Riyadh Saudi Arabia!+966572737505 ) Where to get cytotec
Abortion pills in Riyadh Saudi Arabia!+966572737505 ) Where to get cytotecAbortion pills in Riyadh Saudi Arabia!+966572737505 ) Where to get cytotec
Abortion pills in Riyadh Saudi Arabia!+966572737505 ) Where to get cytotec
Abortion pills in Riyadh +966572737505 get cytotec
 

Recently uploaded (19)

Cytotec 200 mcg in doha [+966572737505 ] buy abortion pills
Cytotec 200 mcg in doha [+966572737505 ] buy abortion pillsCytotec 200 mcg in doha [+966572737505 ] buy abortion pills
Cytotec 200 mcg in doha [+966572737505 ] buy abortion pills
 
如何办理(USYD毕业证书)悉尼大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(USYD毕业证书)悉尼大学毕业证成绩单本科硕士学位证留信学历认证如何办理(USYD毕业证书)悉尼大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(USYD毕业证书)悉尼大学毕业证成绩单本科硕士学位证留信学历认证
 
如何办理(AUT毕业证书)奥克兰理工大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(AUT毕业证书)奥克兰理工大学毕业证成绩单本科硕士学位证留信学历认证如何办理(AUT毕业证书)奥克兰理工大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(AUT毕业证书)奥克兰理工大学毕业证成绩单本科硕士学位证留信学历认证
 
如何办理(SUT毕业证书)斯威本科技大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(SUT毕业证书)斯威本科技大学毕业证成绩单本科硕士学位证留信学历认证如何办理(SUT毕业证书)斯威本科技大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(SUT毕业证书)斯威本科技大学毕业证成绩单本科硕士学位证留信学历认证
 
Cyber-Security-power point presentation.
Cyber-Security-power point presentation.Cyber-Security-power point presentation.
Cyber-Security-power point presentation.
 
办理(uw学位证书)美国华盛顿大学毕业证续费收据一模一样
办理(uw学位证书)美国华盛顿大学毕业证续费收据一模一样办理(uw学位证书)美国华盛顿大学毕业证续费收据一模一样
办理(uw学位证书)美国华盛顿大学毕业证续费收据一模一样
 
NO1 Pakistan Best vashikaran specialist in UK USA UAE London Dubai Canada Ame...
NO1 Pakistan Best vashikaran specialist in UK USA UAE London Dubai Canada Ame...NO1 Pakistan Best vashikaran specialist in UK USA UAE London Dubai Canada Ame...
NO1 Pakistan Best vashikaran specialist in UK USA UAE London Dubai Canada Ame...
 
[[Jeddah]] IN RIYADH +2773-7758557]] Abortion pills in Jeddah Cytotec in Riya...
[[Jeddah]] IN RIYADH +2773-7758557]] Abortion pills in Jeddah Cytotec in Riya...[[Jeddah]] IN RIYADH +2773-7758557]] Abortion pills in Jeddah Cytotec in Riya...
[[Jeddah]] IN RIYADH +2773-7758557]] Abortion pills in Jeddah Cytotec in Riya...
 
Abortion Clinic in Jeddah +966572737505 buy cytotec pills
Abortion Clinic in Jeddah +966572737505 buy cytotec pillsAbortion Clinic in Jeddah +966572737505 buy cytotec pills
Abortion Clinic in Jeddah +966572737505 buy cytotec pills
 
如何办理(OP毕业证书)奥塔哥理工学院毕业证成绩单本科硕士学位证留信学历认证
如何办理(OP毕业证书)奥塔哥理工学院毕业证成绩单本科硕士学位证留信学历认证如何办理(OP毕业证书)奥塔哥理工学院毕业证成绩单本科硕士学位证留信学历认证
如何办理(OP毕业证书)奥塔哥理工学院毕业证成绩单本科硕士学位证留信学历认证
 
Abortion pills in Jeddah Saudi Arabia! +966572737505 Where to buy cytotec
Abortion pills in Jeddah Saudi Arabia! +966572737505 Where to buy cytotecAbortion pills in Jeddah Saudi Arabia! +966572737505 Where to buy cytotec
Abortion pills in Jeddah Saudi Arabia! +966572737505 Where to buy cytotec
 
Vibration of Continuous Systems.pjjjjjjjjptx
Vibration of Continuous Systems.pjjjjjjjjptxVibration of Continuous Systems.pjjjjjjjjptx
Vibration of Continuous Systems.pjjjjjjjjptx
 
如何办理(UVic毕业证书)维多利亚大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(UVic毕业证书)维多利亚大学毕业证成绩单本科硕士学位证留信学历认证如何办理(UVic毕业证书)维多利亚大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(UVic毕业证书)维多利亚大学毕业证成绩单本科硕士学位证留信学历认证
 
Buy best abortion pills Doha [+966572737505 | Planned cytotec Qatar
Buy best abortion pills Doha [+966572737505 | Planned cytotec QatarBuy best abortion pills Doha [+966572737505 | Planned cytotec Qatar
Buy best abortion pills Doha [+966572737505 | Planned cytotec Qatar
 
Balancing of rotating bodies questions.pptx
Balancing of rotating bodies questions.pptxBalancing of rotating bodies questions.pptx
Balancing of rotating bodies questions.pptx
 
Top^Clinic Soweto ^%[+27838792658_termination in florida_Safe*Abortion Pills ...
Top^Clinic Soweto ^%[+27838792658_termination in florida_Safe*Abortion Pills ...Top^Clinic Soweto ^%[+27838792658_termination in florida_Safe*Abortion Pills ...
Top^Clinic Soweto ^%[+27838792658_termination in florida_Safe*Abortion Pills ...
 
Matrix Methods.pptxhhhhhhhhhhhhhhhhhhhhh
Matrix Methods.pptxhhhhhhhhhhhhhhhhhhhhhMatrix Methods.pptxhhhhhhhhhhhhhhhhhhhhh
Matrix Methods.pptxhhhhhhhhhhhhhhhhhhhhh
 
NO1 Best Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Addre...
NO1 Best Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Addre...NO1 Best Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Addre...
NO1 Best Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Addre...
 
Abortion pills in Riyadh Saudi Arabia!+966572737505 ) Where to get cytotec
Abortion pills in Riyadh Saudi Arabia!+966572737505 ) Where to get cytotecAbortion pills in Riyadh Saudi Arabia!+966572737505 ) Where to get cytotec
Abortion pills in Riyadh Saudi Arabia!+966572737505 ) Where to get cytotec
 

75F Outside Air Optimization and Economizer Control

  • 1. 888.590.8995 | support@75f.io | www.75f.io APPLICATION OVERVIEW 75F Outside Air Optimization (OAO) is an application that combines hardware, software and real-time weather data providing advanced sequences of operation from rooftop economizers to built-up air handlers in a wide range of commercial buildings. Facility managers who want to maximize efficiency, occupant comfort and indoor air quality (IAQ) should install OAO on all outside air applications. Customers can also add OAO to maintain pressure inside a building. OAO’s three primary benefits are Improved Efficiency, Comfort and IAQ, something it accomplishes thanks to two main application functions: Economizing and Demand Control Ventilation (DCV). 75F® Outside Air Optimization™ Save energy, provide comfort and improve indoor air quality FEATURES • Works with Variable Air Volume (VAV) and Dynamic Airflow Balancing™ (DAB) to provide advanced economizer controls to RTUs and AHUs • Monitors and analyzes return air CO2 for DCV • Web-based, aggregated weather feeds for outside air temperature and humidity • Backup temperature probe for outside air • Return and outside air damper controls • 2-stage exhaust fan control • Mixed Air Temperature (MAT) and humidity sensing with a minimum temperature safety feature
  • 2. 888.590.8995 | support@75f.io | www.75f.io IMPROVED EFFICIENCY The efficiency of outside air (OA) applications is dramatically improved by employing demand control ventilation (DCV) and comparative enthalpy economy sequences. 75F OAO hardware includes a CO2 sensor installed in the air handler’s return air (RA) duct to determine IAQ and derived occupancy. The OA is modulated with a 0/2-10V actuator controlling the OA and RA dampers. Conditioning OA is inefficient when temperature and humidity are far from desired indoor levels – however, OAO lets a precise amount of air in to balance IAQ and comfort in a space. ASHRAE Standard 62.1 provides direction for the correct ventilation rates of occupied spaces. When occupancy is unknown, the standard calls for assuming the worst case — maximum occupancy — to set the minimum position of the OA damper. In reality, most spaces are not occupied at maximum ,and the result is that most indoor spaces are over-ventilated at the cost of much greater mechanical conditioning and energy cost. Using DCV, OAO from 75F delivers an ASHRAE-approved method to derive occupancy, allowing for adjustments of the OA damper according to CO2 instead of assuming the worst case. The result is energy savings during low occupancy and improved IAQ during high occupancy. OAO also allows buildings to maximize “free cooling”, the basic function of an economizer. A basic economizer — the type typically installed in package units — measures outside air dry-bulb temperature to determine if OA is at or below a certain temperature, usually about 55°F. Based on historical weather data, the basic economizer assumes a relative humidity value to calculate an assumed enthalpy (a measure of both temperature and humidity), and will then open the OA damper to cool indoor spaces. Because the basic economizer is assuming enthalpy based on the dry-bulb temperature and historical humidity levels for a weather zone, the formula is conservative and only provides free cooling for fraction of the available time. Comparative enthalpy economy from 75F’s OAO system is a far superior method to obtain the maximum amount of free cooling because it uses real-time outside enthalpy data and compares it with real-time indoor enthalpy data to lower energy costs and improve efficiency through free cooling. Not only does the system compare the two enthalpy values, it also calculates the final enthalpy of supply air when heated up to indoor levels using psychrometric charts to ensure the resulting air meets a desired target. The result is typically three times more free cooling than a basic economizer and much better comfort for guests and occupants. COMFORT As explained in the previous section, most basic economizers on the market today are typically set to let in OA only when it is 55°F and lower (usually a lower limit is also set). A downside of this is that during winter months, when free cooling is used to bring down the temperature of warmer interior zones, this 55°F or colder air can cause occupant complaints. Any time supply air is noticeably hotter or colder than the indoor environment, comfort is reduced. • Proprietary algorithms reduce energy use by 20-30% with OAO alone. Machine learning optimizes energy efficiency, comfort, and IAQ even further. • Enhanced features compared to traditional zone controls: – Energy savings – Improved Comfort – Optimized IAQ – Easy scheduling – Remote configuration – Fault detection and diagnostics ADVANTAGES • Outside Air Optimization (OAO) from 75F uses web- based, aggregated weather feeds specific to each building. • OAO is simple to install and works out of the box with no programming required. • Wireless design eliminates invasive or complicated installs. • Advanced controls allow the use of OAO on everything from simple rooftop units to sophisticated air handling units. • Fully integrates with 75F Facilisight portal and mobile app.
  • 3. 888.590.8995 | support@75f.io | www.75f.io OAO from 75F continuously measures the temperature and humidity in all occupied spaces and very accurately calculates loads to determine what the best supply air temperature should be. During free cooling periods, 75F will partially open the OA damper to achieve an MAT that is optimal for the load conditions and which will maintain an optimal experience for the occupant. This results in improved comfort, as well as efficiency. IAQ The 75F OAO kit includes a CO2 sensor in the return duct of the air handler to measure the average IAQ of the building’s envelope. When occupancy is high, or when external factors are deteriorating IAQ, 75F will modulate the OA damper proportionally with IAQ values to ventilate with fresh OA to achieve minimum values. Other 75F IAQ sensors such as CO and NO2 can be added to this sequence for spaces like parking garages or other applications. The 75F OAO sequence includes a control point to activate an exhaust fan based on how much OA is entering the envelope. ECONOMIZING Economizers are a feature of HVAC systems which use cold OA to provide free cooling in a space. Outdoor Air Economizing from 75F uses forecasts and temperature data to predictively determine when OA is suitable for free cooling. When OA temperature and humidity is not sufficient to completely cool zones or rooms, then the 75F system utilizes this air instead of the return air coming from building as a prefeed to mechanical cooling. This applies only to cooling modes. Economizer functions are typically based on two parameters, temperature and humidity. Simpler systems only use temperature for this function, whereas more sophisticated systems will use both temperature and humidity. Systems based on temperature and humidity are called enthalpy economizers, as they use the enthalpy of both the outside air and the indoor air to make constant decisions on whether to bring in OA for free cooling. Use averageZoneTemperature and averageZoneHumidity to compute insideAirEnthalpy Use weatherOutsideTemperature and weatherOutsideHumidity to determine the outsideAirEnthalpy If outsideAirEnthalpy + enthalpyDuctCompensationOffset < insideAirEnthalpy then economizingAvailable = true If a building needs cooling, the 75F operating system, Renatus, uses systemCoolingLoopOutput to open the OA damper and will record this change as free cooling used. If any of the staged RTU profiles are used, then OAO forms the first stage of the cooling capacity. For example, where a 3-stage RTU is configured, when economizing is available it will appear as if there are 4 stages to the RTU and the economizing loop (OAO) will map to the first 25% of the systemCoolingLoopOutput. If a fully modulating RTU is used, then the economizingLoopOutput maps to the first economizingToMainCoolingLoopMap as a percentage of the cooling loop. MIXED AIR TEMPERATURE (MAT) SAFETY REGULATIONS If the MAT is above OutsideDamperMixedAirTarget, then the system will start progressively closing the damper until outsideDamperMixedAirMinimum. This is true for both DCV and economizing systems. Simply put, for DCV heating mode, this prevents condensation of flue gases when heating is on, and avoids corrosion due to the acidity that may be present in that condensation. For DCV or economizing in cooling mode, this will cause super cold air to be supplied, which can lower the comfort of occupants and is not desirable.
  • 4. UNDERSTANDING: HUMIDITY & ENTHALPY As water evaporates, it converts into water vapor and cools—this is why sweat or misting systems are so effective. The water vapor in the air stores a huge amount of energy. Enthalpy determines the total amount of energy in the air and is based on both humidity and temperature. While there is no simple math to determine enthalpy, a psychometric chart can be used to discover how much energy is stored in the air. This graphical representation calculates thermodynamic properties like dry-bulb temperature, wet-bulb temperature, humidity, enthalpy and air density. For example, a building has an inside temperature of 72°F with 40% humidity. Let’s also assume that in this example the air outside is significantly cooler at 60°F with 65% humidity. To find enthalpy using a psychometric chart, like the one found below, you first find the temperature reading on the bottom horizontal axis and its associated vertical line, reading left to right. Then, you identify the humidity percentage on the sloping diagonal lines which increase with temperature. Trace both your temperature vertical line and the humidity slope until they meet. Once you have located this point, trace the corresponding diagonal enthalpy line to determine your enthalpy reading. In the chart below we can see that 60°F with 65% humidity has less enthalpy than 72°F with 40% humidity. Therefore, according to the chart, the outdoor enthalpy is less than the indoor enthalpy, and bringing in fresh air to cool the building (instead of mechanical cooling) makes sense. With OAO from 75F, temperature and humidity data is fed into the cloud and referenced against outdoor forecast predictions over time by 75F’s cloud-based AI, Athena. Over one million data points per 50,000sq. ft. of space, and tens of thousands of separate enthalpy decisions are made each day by the 75F OAO application. This psychometric chart indicates that air which is 72˚F with 40% humidity has more energy than air which is 60˚F with 65% humidity. This psychometric chart indicates that air which is 60˚F with 65% humidity will end up with 43% humidity when heated to 72˚F. DCV The system uses CO2 levels to determine the amount of OA that should be brought in to maintain the optimal IAQ. If CO2 readings in a space are below threshold, then DCV has no affect. If CO2 is above threshold, the 75F system will automatically and proportionately open the OA damper. In other words, DCV essentially sets the minimum damper opening level at any given time and is calculated based on either the return air CO2 or individual spaces using a Trim and Respond system. This applies to both cooling and heating in ‘Occupied Mode’. If there are no CO2 sensors in the space, then the system uses the return air CO2 sensor to provide an average CO2 level to control OA dampers appropriately. Generally, CO2 levels are within the threshold level for most buildings the majority of the time. In this case, the system uses outsideDamperMinOpen while above threshold levels and the system is opened to allow more fresh air in.
  • 5. 888.590.8995 | support@75f.io | www.75f.io FINAL DAMPER DRIVE The outside damper output signal will modulate between outsideDamperAtMinDrive and outsideDamperAtMaxDrive as the oaoFinalLoopOutput changes from 0% to 100% depending on the conditions. The return air damper works in opposition to the outside air damper and is calculated as follows: returnAirFinalOutput = 100 - outsideAirFinalLoopOutput CONNECTIVITY In this setup, • Analog-in1 connects to return air CO2 sensor • Analog-in2 connects to RTU current transformer • Th-in1 connects to Outside Air Temperature • Th-in2 connects to Supply Air Temperature • One Wire sensor bus connects to Duct Temperature and Humidity sensor for Mixed Air Temperature and Humidity • Analog-out1 connects to Outside Air Damper • Analog-out2 connects to Return Air Damper • Relay-1 connects to exhaust fan stage 1 • Relay-2 connects to exhaust fan stage 2
  • 6. 888.590.8995 | support@75f.io | www.75f.io KIT OPTIONS CO2 Sensor TYPE PRODUCT NAME COMPONENTS Standard Outside Air Optimization Kit Smart Node, CO2, DS, CT, SAT, OAT Airflow Temperature Sensor COMPONENTS OF OAO 75F Outside Air Optimization includes the 75F Facilisight & Occupant App, a 75F Smart Node, and a 75F Central Control Unit – plus, one 75F Duct Temperature and Humidity Sensor, and a range of external sensors. 75F® Duct Sensor™ 75F® Smart Node™ 75® Facilisight™ & Occupant App™ Current Switch & Sensor ADDERS • Smart Differential Pressure Sensor Kit, with Smart Node, 24V AC Power Supply (#3510) • NO2 sensor • CO2 sensor INCLUDED Outdoor Air Thermistor V1.0 May 6, 2020