NBC108V2.RV9 7 December 1993
N E P A L N A T I O N A L B U I L D I N G C O D E
NBC 111 : 1994
STEEL
Government of Nepal
Ministry of Physical Planning and Works
Department of Urban Development and Building Construction
Babar Mahal, Kathmandu, NEPAL
Reprinted : 2064
NBC108V2.RV9 7 December 1993
N E P A L N A T I O N A L B U I L D I N G C O D E
NBC 111 : 1994
STEEL
tTsflng >L % sf] ;/sf/ -dlGqkl/ifb_ sf] ldlt @)^).$.!@ sf] lg0f{ofg';f/ :jLs[t
Government of Nepal
Ministry of Physical Planning and Works
Department of Urban Development and Building Construction
Babar Mahal, Kathmandu, NEPAL
Reprinted : 2064
This publication represents a standard of good practice and therefore
takes the form of recommendations. Compliance with it does not confer
immunity from relevant legal requirements, including bylaws
NBC111VO.RV2 7December 1993
Preface
This Nepal Standard was prepared during 1993 as part of a project to prepare a National Building
Code for Nepal.
In 1988 the Ministry of Housing and Physical Planning (MHPP), conscious of the growing needs of
Nepal's urban and shelter sectors, requested technical assistance from the United Nations Development
Programme and their executing agency, United Nations Centre for Human Settlements (UNCHS).
A programme of Policy and Technical Support was set up within the Ministry (UNDP Project
NEP/88/054) and a number of activities have been undertaken within this framework.
The 1988 earthquake in Nepal, and the resulting deaths and damage to both housing and schools, again
drew attention to the need for changes and improvement in current building construction and design
methods.
Until now, Nepal has not had any regulations or documents of its own setting out either requirements
or good practice for achieving satisfactory strength in buildings.
In late 1991 the MHPP and UNCHS requested proposals for the development of such regulations and
documents from international organisations in response to terms of reference prepared by a panel of
experts.
this document has been prepared by the subcontractor's team working within the Department of
Building, the team including members of the Department and the MHPP. As part of the proposed
management and implementation strategy, it has been prepared so as to conform with the general
presentation requirements of the Nepal Bureau of Standards and Metrology.
The subproject has been undertaken under the aegis of an Advisory Panel to the MHPP.
The Advisory Panel consisted of :
Mr. UB Malla, Joint Secretary, MHPP Chairman
Director General, Department of Building
(Mr. LR Upadhyay) Member
Mr. AR Pant, Under Secretary, MHPP Member
Director General, Department of Mines & Geology
(Mr. PL Shrestha) Member
Director General, Nepal Bureau of Standards & Metrology
(Mr. PB Manandhar) Member
Dean, Institute of Engineering, Tribhuvan University
(Dr. SB Mathe) Member
Project Chief, Earthquake Areas Rehabilitation &
Reconstruction Project Member
President, Nepal Engineers Association Member
Law Officer, MHPP (Mr. RB Dange) Member
Representative, Society of Consulting Architectural &
Engineering Firms (SCAEF) Member
i
NBC111VO.RV2 7December 1993
Representative, Society of Nepalese Architects (SONA) Member
Deputy Director General, Department of Building,
(Mr. JP Pradhan) Member-Secretary
The Subcontractor was BECA WORLEY INTERNATIONAL CONSULTANTS LTD. of New
Zealand in conjunction with subconsultants who included :
Golder Associates Ltd., Canada
SILT Consultants P. Ltd., Nepal
TAEC Consult (P.) Ltd., Nepal
Urban Regional Research, USA
Principal inputs to this standard came from :
Mr. RD Jury, BECA
Revisions and Updated to this code came from :
Mr. Purna P. Kadariya, DG, DUDBC
Mr. Kishore Thapa, DDG, DUDBC
Mr. Mani Ratna Tuladhar, Sr. DIV. Engineer, DUDBC
Mr. Jyoti Prasad Pradhan, Ex.DG, DOB
Mr. Bhubaneswor Lal Shrestha, Ex. DDG, DOB
Mr. Uttam Shrestha, Architect, Architects' Module Pvt. Ltd.
Mr. Manohar Lal Rajbhandhari, Sr. Structural Engineer, Mr Associates
Mr. Amrit Man Tuladhar, Civil Engineer, DUDBC
ii
NBC111VO.RV2 7December 1993
TABLE OF CONTENTS
Preface ..................................................................................................................................................... i
0 Foreword.................................................................................................................................. iv
1 Scope.......................................................................................................................................... 1
NEPAL AMENDMENTS TO IS 800 – 1984 .............................................................. 1
SECTION 0...................................................................................................................... 1
SECTION 1-GENERAL .................................................................................................... 1
SECTION 2 – MATERIALS .............................................................................................. 2
SECTION 3 – GENERAL DESIGN REQUIREMENTS ......................................................... 2
SECTION 10.................................................................................................................... 4
SECTION 12.................................................................................................................... 4
SECTION 13 -PROVISIONS FOR SEISMIC DESIGN .......................................................... 4
iii
NBC111VO.RV2 7December 1993
0 Foreword
This Nepal Standard comprises the Indian Code IS 800-1984 Code of practice for General
Construction in Steel (Second Revision) with amendments as set out herein. These amendments
have been necessary to ensure compatibility with the Nepal Standard- Seismic Design of
Buildings in Nepal.
References to Indian material codes have been left unaltered until such time as appropriate
Nepal Standards are developed.
Extensive use of the New Zealand Standard NZS 3404 : 1977 Code for Design of Steel
Structures have been made in the preparation of Section 13.
iv
NBC111VO.RV2 7December 1993
1 Scope
NEPAL AMENDMENTS TO IS 800 – 1984
Section 0 Delete clauses 0.1 through to 0.5 inclusively
Section 1 - General
1.1.1 Delete 1.1.1 and substitute :
1.1.1 This standard applies to general construction in steel. This standard does not
apply to the following structures and materials:
(a) bridges
(b) cranes
(c) tanks
(d) transmission towers
(e) materials less than 3 mm thick
(f) cold-formed light gauge sections
1.1.2 Replace "code" with "standard"
1.1.3 Replace "code" with "standard"
Replace IS 875-1964 with NBC 103-2050 and NBC 104-2050
1.1.4 Add new clause :
1.1.4 In this standard the word "shall" indicates a requirement that must be
adopted in order to comply with the Standard.
1.2 Replace "code" with "standard".
1.3 Replace "code" with "standard".
1.4 Replace IS 456-1976 with NBC 110-2050
Replace IS 1893-1975 with NBC 105-2050
1.5 Delete 1.5 and substitute :
1.5 Units and Conversion Factors – The SI system of units is applicable to this
standard.
1.7 Delete 1.7 and substitute :
1.7 Design and supervision
1.7.1 Design
1
NBC111VO.RV2 7December 1993
The design of a structure or part of a structure to which this standard is
applied shall be the responsibility of a engineer (referred herein as
Design Engineer or his representative) experienced in the design of such
structures.
1.7.2 Supervisor
All stages of construction of a structure or part of a structure to which the
standard is applied shall be adequately supervised to ensure that all
requirements of the design are satisfied in the completed structure.
Supervision shall be the responsibility of either :
(a) the Design Engineer, or
(b) an engineer experienced in such supervision.
Section 2 – Materials
2.1 Replace "code" with "standard"
2.1.2 Add new clause :
2.1.2 The maximum value of ƒy to be used in application of this Standard shall
be 450 MPa.
Section 3 – General Design Requirements
3.1.1.1 Replace "IS 875 – 1964" with NBC 103-2050 and NBC 104-2050.
3.1.1.4 Replace "IS 1893 – 1975" with NBC 105-2050 and NBC 104-2050.
3.2.1 8th line, replace "code" with "standard".
3.2.2 4th line, replace "India" with "Nepal".
[Will require preparation of maps for Nepal to replace those in Appendix A]
3.4.2.2 Delete 3.4.2.2 and substitute :
3.4.2.2 Wind loads and earthquake loads need not be assumed to act
simultaneously.
3.4.5 9th line, replace "code" with "standard".
3.4.6 9th line, replace "code" with "standard".
3.9.2.1 Delete and substitute :
2
NBC111VO.RV2 7December 1993
3.9.2.1 Wind and Earthquake Loads
(a) Structural steel and steel castings – when the effect of wind or
earthquake load is taken in to account, the permissable stresses
specified may be increased by not more than 33.3 percent except
for the permissable shear stresses which shall not be exceeded by
more than 25 percent. The values of the expressions given in
Section 7 shall not exceed 1.33.
(b) Rivets and bolts – when the effect of wind or earthquake load is
taken in to account, the permissible stresses specified may be
increased by not more than 25 percent.
3.11 Delete and substiute :
3.11.1 Earthquake forces
The design of structures to resist earthquakes shall be in accordance with
the Nepal Standard – Seismic Design of Buildings in Nepal and Section
13 of this Standard.
3.11.2 Lateral Restraint
In buildings where high-speed travelling cranes are supported by the
structure, or where a building or structure is otherwise subjected to
vibration or sway, triangulated bracing, rigid portal systems or other
suitable systems shall be provided to reduce bivration or sway to suitable
minimum.
3.11.3 Foundations
The foundations of a building or other structure shall be designed to
provide the lateral rigidity and strength assumed in the design of the
superstructure and to transfer the lateral forces to the soil.
3.12.1.2 Correct spelling of "repair".
Add a new clause :
3.12.1.3 Eccentric Loading
Where a load is applied eccentrically on a flange of a supporting steel
beam, the beam and its connections shall be designed for torsion; unless
the beam is encased in concrete and reinforced in combination with an
adjoining floor slab in such a way as to present the beam from deforming
torsionally.
3
NBC111VO.RV2 7December 1993
3.13.2 Add an additional clause :
3.12.2.3 Deflection Limits
Under the application of the earthquake design forces the deflections
shall not exceed the limits given in NBC 105-2050, Seismic Design of
Buildings in Nepal.
3.14 Add additional clause :
3.14.4 Separate Structures
All parts of a structure separated by expansion joints shall be considered
as separate structures for the purposes of providing lateral restraint to
resist earthquake frames.
Section 10 Add after the heading a sentence reading :
This Section shall apply only to secondary (i.e. non seismic resisting) members.
Section 12 After Section 12 add a new section :
Section 13 - Provisions for Seismic Design
13.1 Ductile Moment-Resisting Frames
13.1.1 General
Moment-resisting frames for which a value of K = 1.0 is to be used in the
assessment of the earthquake design forces shall be detailed in
accordance with 13.1.
13.1.2 Steels
Steel with a specified minimum yield stress not exceeding 360 MPa shall
be used. Cold-formed sections which have not been normalised shall not
be used.
13.1.3 Plastic Hinge Formation in Beams
For the purposes of 13.1, plastic hinges in beams shall be assumed to
form be used. Cold-formed sections which have not been normalised
shall not be used.
4
NBC111VO.RV2 7December 1993
13.1.4 Lateral Restraint
Positions of beams where plastic hings may form during inelastic
displacements of the frame, and all columns shall comply with 9.2.10.
The remaining portions of the beams shall comply with 6.6.
13.1.5 Effective Lengths of Columns and Stability
The effective length used in determining the slenderness ratio of a loaded
column shall be based on the assumption that the frame depends on its
own bending stiffness to provide the lateral stability of the structure, as
specified in 5.2.2, even if bracing or shear walls are provided elsewhere
in the structure.
13.1.6 Plastic Hinge Formation and Column Strength
Multi-storey frames should be designed so as to ensure that plastic hinge
formation in the columns is minimised. To this end, it is suggested that in
frames over five storeys in height columns should be proportioned for
actions calculated in accordance with the Nepal Standard – Seismic
Design of Buildings in Nepal, taking K = 1.25. This will provide some
reserve in the columns but will not necessarily prevent some plastic
hinging in the columns.
13.1.7 Connections
Each beam connected to a column shall be designed either to resist 1.25
times the design actions in the connected members, or the actions
resulting from applications of design forces calculated using K = 4,
whichever is less. Clause 9.2.1 shall apply, except that stiffeners shall
extend over the full depth between flanges and shall be butt-welded to
both flanges.
13.1.8 Concrete Encasement of Steel Frames
The effects of concrete-encasement and floor slabs on frame stiffness
shall be considered.
13.1.9 Column Splices
Splices in columns should be located within the middle half of the storey
height.
13.1.10 Weld Testing
All tension butt-welds between members shall be non-destructively
tested unlesss the rejection rate of completed welds is consistently less
than 5 percent, in which case the testing rate may be reduced to 25
percent of the welds.
5
NBC111VO.RV2 7December 1993
13.2 Ductile Braced Frames
13.2.1 General
Diagonally-braced frames for which a value of K = 2.0 or a steel bracing
member for which a valud K = 1.0 is to be used in the assessment of the
earthquake design forces shall be detailed in accordance with 13.2.
13.2.2 Relative Strengths
Members, connections and foundations should be designed and
proportioned so that the bracing reaches its actual yield load with an
appropriate allowance for strain hardening before the associated columns
reach their buckling load or before any connections between members
and the foundations reach their ultimate strength. However, under no
circumstances shall either the columns or the connections be designed for
less than 1.25 times the design actions in the braces, provided that these
actions need not be taken larger than those resulting from the use of
K = 4.
13.2.3 Mixed Systems
Frames which resist horizontal loads by a mixed system of axially loaded
members and flexural members shall also comply with the requirements
of 13.1.
6
NBC111VO.RV2 7December 1993
25
35
40
42.5
45
32
31
30
29
28
27
26
25
80 82 84 86 88
NEPAL
MAP SHOWING HIGHEST MAXIMUMTEMPERATURE
N
APPENDIX A
7
NBC111VO.RV2 7December 1993
NEPAL
32
31
30
29
28
27
26
25
80 82 84 86 88
MAP SHOWING LOWEST MINIMUMTEMPERATURE
-15
-10
-5
0
+2.5
N
APPENDIX B
8

More Related Content

Similar to Steel

Ebcs 1 basis of design actions on structures
Ebcs 1 basis of design   actions on structuresEbcs 1 basis of design   actions on structures
Ebcs 1 basis of design actions on structures
Alemu Osore
 
Sp34 str detailing
Sp34     str detailingSp34     str detailing
Sp34 str detailing
Mohd Danish
 

Similar to Steel (20)

NBC 2016-VOL.2.pdf
NBC 2016-VOL.2.pdfNBC 2016-VOL.2.pdf
NBC 2016-VOL.2.pdf
 
india-national-building-code-nbc-2016-vol-2.pdf
india-national-building-code-nbc-2016-vol-2.pdfindia-national-building-code-nbc-2016-vol-2.pdf
india-national-building-code-nbc-2016-vol-2.pdf
 
875 2
875 2875 2
875 2
 
Aashto guide specifications for lrfd seismic
Aashto guide specifications for lrfd seismicAashto guide specifications for lrfd seismic
Aashto guide specifications for lrfd seismic
 
IS.875.2.1987
IS.875.2.1987IS.875.2.1987
IS.875.2.1987
 
875 2
875 2875 2
875 2
 
457
457457
457
 
IS 875 5
IS 875 5IS 875 5
IS 875 5
 
Sp22
Sp22Sp22
Sp22
 
5525
55255525
5525
 
2506
25062506
2506
 
875 5
875 5875 5
875 5
 
Analysis and design of multi-storey building using staad.Pro
Analysis and design of multi-storey building using staad.ProAnalysis and design of multi-storey building using staad.Pro
Analysis and design of multi-storey building using staad.Pro
 
Design-standards-for-railway-structures-and-commentary-concrete-structures-20...
Design-standards-for-railway-structures-and-commentary-concrete-structures-20...Design-standards-for-railway-structures-and-commentary-concrete-structures-20...
Design-standards-for-railway-structures-and-commentary-concrete-structures-20...
 
Ebcs 1 basis of design actions on structures
Ebcs 1 basis of design   actions on structuresEbcs 1 basis of design   actions on structures
Ebcs 1 basis of design actions on structures
 
2502
25022502
2502
 
Sp 34-1987 handbook on reinforcement and detailing
Sp 34-1987 handbook on reinforcement and detailingSp 34-1987 handbook on reinforcement and detailing
Sp 34-1987 handbook on reinforcement and detailing
 
Sp34 str detailing
Sp34     str detailingSp34     str detailing
Sp34 str detailing
 
Inception Report
Inception ReportInception Report
Inception Report
 
6509
65096509
6509
 

Recently uploaded

1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
AldoGarca30
 
DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
MayuraD1
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
Kamal Acharya
 

Recently uploaded (20)

Double Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torqueDouble Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torque
 
💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...
💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...
💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...
 
Linux Systems Programming: Inter Process Communication (IPC) using Pipes
Linux Systems Programming: Inter Process Communication (IPC) using PipesLinux Systems Programming: Inter Process Communication (IPC) using Pipes
Linux Systems Programming: Inter Process Communication (IPC) using Pipes
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptxOrlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
 
Electromagnetic relays used for power system .pptx
Electromagnetic relays used for power system .pptxElectromagnetic relays used for power system .pptx
Electromagnetic relays used for power system .pptx
 
Ground Improvement Technique: Earth Reinforcement
Ground Improvement Technique: Earth ReinforcementGround Improvement Technique: Earth Reinforcement
Ground Improvement Technique: Earth Reinforcement
 
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
 
Employee leave management system project.
Employee leave management system project.Employee leave management system project.
Employee leave management system project.
 
PE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and propertiesPE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and properties
 
Basic Electronics for diploma students as per technical education Kerala Syll...
Basic Electronics for diploma students as per technical education Kerala Syll...Basic Electronics for diploma students as per technical education Kerala Syll...
Basic Electronics for diploma students as per technical education Kerala Syll...
 
Max. shear stress theory-Maximum Shear Stress Theory ​ Maximum Distortional ...
Max. shear stress theory-Maximum Shear Stress Theory ​  Maximum Distortional ...Max. shear stress theory-Maximum Shear Stress Theory ​  Maximum Distortional ...
Max. shear stress theory-Maximum Shear Stress Theory ​ Maximum Distortional ...
 
DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
 
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptxS1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
 
Introduction to Data Visualization,Matplotlib.pdf
Introduction to Data Visualization,Matplotlib.pdfIntroduction to Data Visualization,Matplotlib.pdf
Introduction to Data Visualization,Matplotlib.pdf
 
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptxHOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdf
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
 

Steel

  • 1. NBC108V2.RV9 7 December 1993 N E P A L N A T I O N A L B U I L D I N G C O D E NBC 111 : 1994 STEEL Government of Nepal Ministry of Physical Planning and Works Department of Urban Development and Building Construction Babar Mahal, Kathmandu, NEPAL Reprinted : 2064
  • 2. NBC108V2.RV9 7 December 1993 N E P A L N A T I O N A L B U I L D I N G C O D E NBC 111 : 1994 STEEL tTsflng >L % sf] ;/sf/ -dlGqkl/ifb_ sf] ldlt @)^).$.!@ sf] lg0f{ofg';f/ :jLs[t Government of Nepal Ministry of Physical Planning and Works Department of Urban Development and Building Construction Babar Mahal, Kathmandu, NEPAL Reprinted : 2064 This publication represents a standard of good practice and therefore takes the form of recommendations. Compliance with it does not confer immunity from relevant legal requirements, including bylaws
  • 3. NBC111VO.RV2 7December 1993 Preface This Nepal Standard was prepared during 1993 as part of a project to prepare a National Building Code for Nepal. In 1988 the Ministry of Housing and Physical Planning (MHPP), conscious of the growing needs of Nepal's urban and shelter sectors, requested technical assistance from the United Nations Development Programme and their executing agency, United Nations Centre for Human Settlements (UNCHS). A programme of Policy and Technical Support was set up within the Ministry (UNDP Project NEP/88/054) and a number of activities have been undertaken within this framework. The 1988 earthquake in Nepal, and the resulting deaths and damage to both housing and schools, again drew attention to the need for changes and improvement in current building construction and design methods. Until now, Nepal has not had any regulations or documents of its own setting out either requirements or good practice for achieving satisfactory strength in buildings. In late 1991 the MHPP and UNCHS requested proposals for the development of such regulations and documents from international organisations in response to terms of reference prepared by a panel of experts. this document has been prepared by the subcontractor's team working within the Department of Building, the team including members of the Department and the MHPP. As part of the proposed management and implementation strategy, it has been prepared so as to conform with the general presentation requirements of the Nepal Bureau of Standards and Metrology. The subproject has been undertaken under the aegis of an Advisory Panel to the MHPP. The Advisory Panel consisted of : Mr. UB Malla, Joint Secretary, MHPP Chairman Director General, Department of Building (Mr. LR Upadhyay) Member Mr. AR Pant, Under Secretary, MHPP Member Director General, Department of Mines & Geology (Mr. PL Shrestha) Member Director General, Nepal Bureau of Standards & Metrology (Mr. PB Manandhar) Member Dean, Institute of Engineering, Tribhuvan University (Dr. SB Mathe) Member Project Chief, Earthquake Areas Rehabilitation & Reconstruction Project Member President, Nepal Engineers Association Member Law Officer, MHPP (Mr. RB Dange) Member Representative, Society of Consulting Architectural & Engineering Firms (SCAEF) Member i
  • 4. NBC111VO.RV2 7December 1993 Representative, Society of Nepalese Architects (SONA) Member Deputy Director General, Department of Building, (Mr. JP Pradhan) Member-Secretary The Subcontractor was BECA WORLEY INTERNATIONAL CONSULTANTS LTD. of New Zealand in conjunction with subconsultants who included : Golder Associates Ltd., Canada SILT Consultants P. Ltd., Nepal TAEC Consult (P.) Ltd., Nepal Urban Regional Research, USA Principal inputs to this standard came from : Mr. RD Jury, BECA Revisions and Updated to this code came from : Mr. Purna P. Kadariya, DG, DUDBC Mr. Kishore Thapa, DDG, DUDBC Mr. Mani Ratna Tuladhar, Sr. DIV. Engineer, DUDBC Mr. Jyoti Prasad Pradhan, Ex.DG, DOB Mr. Bhubaneswor Lal Shrestha, Ex. DDG, DOB Mr. Uttam Shrestha, Architect, Architects' Module Pvt. Ltd. Mr. Manohar Lal Rajbhandhari, Sr. Structural Engineer, Mr Associates Mr. Amrit Man Tuladhar, Civil Engineer, DUDBC ii
  • 5. NBC111VO.RV2 7December 1993 TABLE OF CONTENTS Preface ..................................................................................................................................................... i 0 Foreword.................................................................................................................................. iv 1 Scope.......................................................................................................................................... 1 NEPAL AMENDMENTS TO IS 800 – 1984 .............................................................. 1 SECTION 0...................................................................................................................... 1 SECTION 1-GENERAL .................................................................................................... 1 SECTION 2 – MATERIALS .............................................................................................. 2 SECTION 3 – GENERAL DESIGN REQUIREMENTS ......................................................... 2 SECTION 10.................................................................................................................... 4 SECTION 12.................................................................................................................... 4 SECTION 13 -PROVISIONS FOR SEISMIC DESIGN .......................................................... 4 iii
  • 6. NBC111VO.RV2 7December 1993 0 Foreword This Nepal Standard comprises the Indian Code IS 800-1984 Code of practice for General Construction in Steel (Second Revision) with amendments as set out herein. These amendments have been necessary to ensure compatibility with the Nepal Standard- Seismic Design of Buildings in Nepal. References to Indian material codes have been left unaltered until such time as appropriate Nepal Standards are developed. Extensive use of the New Zealand Standard NZS 3404 : 1977 Code for Design of Steel Structures have been made in the preparation of Section 13. iv
  • 7. NBC111VO.RV2 7December 1993 1 Scope NEPAL AMENDMENTS TO IS 800 – 1984 Section 0 Delete clauses 0.1 through to 0.5 inclusively Section 1 - General 1.1.1 Delete 1.1.1 and substitute : 1.1.1 This standard applies to general construction in steel. This standard does not apply to the following structures and materials: (a) bridges (b) cranes (c) tanks (d) transmission towers (e) materials less than 3 mm thick (f) cold-formed light gauge sections 1.1.2 Replace "code" with "standard" 1.1.3 Replace "code" with "standard" Replace IS 875-1964 with NBC 103-2050 and NBC 104-2050 1.1.4 Add new clause : 1.1.4 In this standard the word "shall" indicates a requirement that must be adopted in order to comply with the Standard. 1.2 Replace "code" with "standard". 1.3 Replace "code" with "standard". 1.4 Replace IS 456-1976 with NBC 110-2050 Replace IS 1893-1975 with NBC 105-2050 1.5 Delete 1.5 and substitute : 1.5 Units and Conversion Factors – The SI system of units is applicable to this standard. 1.7 Delete 1.7 and substitute : 1.7 Design and supervision 1.7.1 Design 1
  • 8. NBC111VO.RV2 7December 1993 The design of a structure or part of a structure to which this standard is applied shall be the responsibility of a engineer (referred herein as Design Engineer or his representative) experienced in the design of such structures. 1.7.2 Supervisor All stages of construction of a structure or part of a structure to which the standard is applied shall be adequately supervised to ensure that all requirements of the design are satisfied in the completed structure. Supervision shall be the responsibility of either : (a) the Design Engineer, or (b) an engineer experienced in such supervision. Section 2 – Materials 2.1 Replace "code" with "standard" 2.1.2 Add new clause : 2.1.2 The maximum value of ƒy to be used in application of this Standard shall be 450 MPa. Section 3 – General Design Requirements 3.1.1.1 Replace "IS 875 – 1964" with NBC 103-2050 and NBC 104-2050. 3.1.1.4 Replace "IS 1893 – 1975" with NBC 105-2050 and NBC 104-2050. 3.2.1 8th line, replace "code" with "standard". 3.2.2 4th line, replace "India" with "Nepal". [Will require preparation of maps for Nepal to replace those in Appendix A] 3.4.2.2 Delete 3.4.2.2 and substitute : 3.4.2.2 Wind loads and earthquake loads need not be assumed to act simultaneously. 3.4.5 9th line, replace "code" with "standard". 3.4.6 9th line, replace "code" with "standard". 3.9.2.1 Delete and substitute : 2
  • 9. NBC111VO.RV2 7December 1993 3.9.2.1 Wind and Earthquake Loads (a) Structural steel and steel castings – when the effect of wind or earthquake load is taken in to account, the permissable stresses specified may be increased by not more than 33.3 percent except for the permissable shear stresses which shall not be exceeded by more than 25 percent. The values of the expressions given in Section 7 shall not exceed 1.33. (b) Rivets and bolts – when the effect of wind or earthquake load is taken in to account, the permissible stresses specified may be increased by not more than 25 percent. 3.11 Delete and substiute : 3.11.1 Earthquake forces The design of structures to resist earthquakes shall be in accordance with the Nepal Standard – Seismic Design of Buildings in Nepal and Section 13 of this Standard. 3.11.2 Lateral Restraint In buildings where high-speed travelling cranes are supported by the structure, or where a building or structure is otherwise subjected to vibration or sway, triangulated bracing, rigid portal systems or other suitable systems shall be provided to reduce bivration or sway to suitable minimum. 3.11.3 Foundations The foundations of a building or other structure shall be designed to provide the lateral rigidity and strength assumed in the design of the superstructure and to transfer the lateral forces to the soil. 3.12.1.2 Correct spelling of "repair". Add a new clause : 3.12.1.3 Eccentric Loading Where a load is applied eccentrically on a flange of a supporting steel beam, the beam and its connections shall be designed for torsion; unless the beam is encased in concrete and reinforced in combination with an adjoining floor slab in such a way as to present the beam from deforming torsionally. 3
  • 10. NBC111VO.RV2 7December 1993 3.13.2 Add an additional clause : 3.12.2.3 Deflection Limits Under the application of the earthquake design forces the deflections shall not exceed the limits given in NBC 105-2050, Seismic Design of Buildings in Nepal. 3.14 Add additional clause : 3.14.4 Separate Structures All parts of a structure separated by expansion joints shall be considered as separate structures for the purposes of providing lateral restraint to resist earthquake frames. Section 10 Add after the heading a sentence reading : This Section shall apply only to secondary (i.e. non seismic resisting) members. Section 12 After Section 12 add a new section : Section 13 - Provisions for Seismic Design 13.1 Ductile Moment-Resisting Frames 13.1.1 General Moment-resisting frames for which a value of K = 1.0 is to be used in the assessment of the earthquake design forces shall be detailed in accordance with 13.1. 13.1.2 Steels Steel with a specified minimum yield stress not exceeding 360 MPa shall be used. Cold-formed sections which have not been normalised shall not be used. 13.1.3 Plastic Hinge Formation in Beams For the purposes of 13.1, plastic hinges in beams shall be assumed to form be used. Cold-formed sections which have not been normalised shall not be used. 4
  • 11. NBC111VO.RV2 7December 1993 13.1.4 Lateral Restraint Positions of beams where plastic hings may form during inelastic displacements of the frame, and all columns shall comply with 9.2.10. The remaining portions of the beams shall comply with 6.6. 13.1.5 Effective Lengths of Columns and Stability The effective length used in determining the slenderness ratio of a loaded column shall be based on the assumption that the frame depends on its own bending stiffness to provide the lateral stability of the structure, as specified in 5.2.2, even if bracing or shear walls are provided elsewhere in the structure. 13.1.6 Plastic Hinge Formation and Column Strength Multi-storey frames should be designed so as to ensure that plastic hinge formation in the columns is minimised. To this end, it is suggested that in frames over five storeys in height columns should be proportioned for actions calculated in accordance with the Nepal Standard – Seismic Design of Buildings in Nepal, taking K = 1.25. This will provide some reserve in the columns but will not necessarily prevent some plastic hinging in the columns. 13.1.7 Connections Each beam connected to a column shall be designed either to resist 1.25 times the design actions in the connected members, or the actions resulting from applications of design forces calculated using K = 4, whichever is less. Clause 9.2.1 shall apply, except that stiffeners shall extend over the full depth between flanges and shall be butt-welded to both flanges. 13.1.8 Concrete Encasement of Steel Frames The effects of concrete-encasement and floor slabs on frame stiffness shall be considered. 13.1.9 Column Splices Splices in columns should be located within the middle half of the storey height. 13.1.10 Weld Testing All tension butt-welds between members shall be non-destructively tested unlesss the rejection rate of completed welds is consistently less than 5 percent, in which case the testing rate may be reduced to 25 percent of the welds. 5
  • 12. NBC111VO.RV2 7December 1993 13.2 Ductile Braced Frames 13.2.1 General Diagonally-braced frames for which a value of K = 2.0 or a steel bracing member for which a valud K = 1.0 is to be used in the assessment of the earthquake design forces shall be detailed in accordance with 13.2. 13.2.2 Relative Strengths Members, connections and foundations should be designed and proportioned so that the bracing reaches its actual yield load with an appropriate allowance for strain hardening before the associated columns reach their buckling load or before any connections between members and the foundations reach their ultimate strength. However, under no circumstances shall either the columns or the connections be designed for less than 1.25 times the design actions in the braces, provided that these actions need not be taken larger than those resulting from the use of K = 4. 13.2.3 Mixed Systems Frames which resist horizontal loads by a mixed system of axially loaded members and flexural members shall also comply with the requirements of 13.1. 6
  • 13. NBC111VO.RV2 7December 1993 25 35 40 42.5 45 32 31 30 29 28 27 26 25 80 82 84 86 88 NEPAL MAP SHOWING HIGHEST MAXIMUMTEMPERATURE N APPENDIX A 7
  • 14. NBC111VO.RV2 7December 1993 NEPAL 32 31 30 29 28 27 26 25 80 82 84 86 88 MAP SHOWING LOWEST MINIMUMTEMPERATURE -15 -10 -5 0 +2.5 N APPENDIX B 8