1. C U R R I C U L U M V I T A E
Engr.Ashfaq JanEngr.Ashfaq Jan
Pakistan Engineering Council Registration No: ELECT/23253
GENERAL INFORMATION:
Name: Ashfaq Jan
Father’s Name:Fazal Azim
Marital Status: Married
Date of Birth: 1st
June, 1984
Domicile: Charsadda (KPK)
CNIC #:17101-7498669-5
Passport #: BC8796691
Mailing Add: Village sheikh kaley, P.O Agra Miana, Tehsil and District Charsadda,
KPK.Pakistan
Permanent Add: Village sheikh kaley, P.O Agra Miana, Tehsil and District Charsadda,
KPK.Pakistan
Email: ashfaq_105@yahoo.com / ashfaq_jan@live.com
Contact #: +92-300-9338820
EDUCATION:
B.Sc Electrical Engineering with honors
Institution: University Of Engineering and Technology, Peshawar Pakistan
Passing Year: 2007
FIELD OF INEREST:
Electrical Maintenance
Electrical Protection
Testing and commissioning
EXPERIENCE AND JOB HISTORY
FROM MARCH 2008 TO JULY 2012
Worked as Electrical Maintenance Engineer in 1450 MW, Ghazi Barotha power plant and 500KV
Switchyard, WAPDA (Water and Power Development Authority, Pakistan) with following duties;
1. HV System and Power Transformers
Page 1 of 4
2. 500KV switchyard and ABB 107 MVA Transformers
Repair and maintenance of ABB 500KV Bus bar and SF6 circuit breakers, etc
Repair and Maintenance of ABB 107MVA Power Transformers
Oil Dielectric strength test
Meggering
Power and dissipation factor test
Transformer turns ratio
Oil test and dehydration
2. LV and DC System
Repair and maintenance of LV Switch gears, breakers, MCB, disconnect Switches, UPS and Aux
Transformers
3. Generators and Unit Excitation system
290MW Toshiba Units are installed at Barotha Power House. The static excitation system used
at Barotha power complex.The trouble shooting includes:
Meggering of stator and rotor
Poles turn ratio Test
Repair and maintenance of air gap monitoring
Repair and maintenance of Slip rings, Carbon brushes
Repair and maintenance of ventilation unit.
Replacement of defective PCB cards in converter electronics, measuring interface etc.
Trouble shooting of field circuit breaker.
FROM AUGUST 2012 TO DATE WORKING AS PROTECTION ENGINEER
Setting and Testing of the following protective relays regarding generator, transformer,
and transmission lines
1. Relay Testing and Setting Calculations.
ABB numerical Relays REL 512 RET 541 and REG 316
Direct Logic PLC’s 05,06 and 205
Restricted earth fault relay 7VH 6000/6002
Over current relays MCGG 22,62,82 (ALSTOM)
Over voltage relays MVTD 12, MVTU 12
CEWE Energy meters (Prometers) 4322 and 4363
Sineax programmable transducers DME442, etc
Line Over voltage Relay MVTD 12 & MVTU 12.
Shunt Reactor over current Protection MCGG 82.
Shunt Reactor REF Protection MFAC 14 & MFAC 34.
Page 2 of 4
3. Installation and revision of the settings of ABB, Siemens and Dirct logic numerical relays.etc
Testing and calibration of different gauges, indicators, flow switches, meters, alarm and trip
system of gen. T/f and 500Kv breakers,
2. Equipment used
Omicron
C&DF
Insulation Taster
Megger
Oil Tester
Oil Purification Plant
Various Software’s for relays through Laptop and etc
3. Other Duties
Preparation of annual budget for procurement of spares
Issuance and Cancellation of PTW’s and Self Protection tag’s
Cancellation of trouble reports
Monitoring of daily and monthly check sheets
Preparation of Monthly and Annual Reports
Management of technical staff
TRAININGS
1. Junior Management course at WAPDA staff and administrative college Islamabad Pakistan held from
21.01.2013 to 22.03.2013 (Duration 08 Weeks).
2. Sector Specific Course at WAPDA training center Mangla held from 06.01.2014 to 14.02.2014
(Duration 06 Weeks).
CERTIFICATES
Certificate of competency issued by government of NWFP, Pakistan for supervision of
all types of electric installations
COMPUTER SKILLS
MS office
C++
Electronic workbench
Mat lab
P.spice
Page 3 of 4