The Study and Modeling of Organic Rankine Cycle (ORC)Drawback of using waterIn case of low temperature Rankine cycles, the...
Working Fluids and their ComparisonsThe physical properties of the working fluid are of key importance and influence the b...
Organic fluids usually suffer chemical deteriorations and decomposition at high temperatures.The maximum hot source temper...
R-22 and R-134a can be eliminated, their temperature range being too lowWater, benzene, toluene and p-xylene have a too hi...
R-11 and R-113 have a very high ozone depleting potential (ODP), and were phased out in1996 by the Montreal protocolR-123,...
Effect of Irreversibilities:The effect of irreversibilities in the cycle is a reduction of the cycle efficiency and useful...
When used in smaller units, the turbomachines have a lower radius R, and their optimalrotational speed is therefore increa...
Expanders may be lubricated or not. Lubrication reduces the friction between the relativemoving parts and reduces the leak...
The flank leakage is due to the clearance between the flanks of the two scrolls, and the radialleakage is due the clearanc...
PumpPump can be a hydraulic diaphragm type pump. In it the piston transmits the power to the fluidby the intermediary of a...
They have a major advantage over conventional heat exchangers in that, the fluids being spreadout all over the plates, the...
The thermocouples of Type-T (Copper/Constantan), with a tolerance “class 1” are suitable formeasurements in the −200 to 40...
In order to measure the amount of electrical energy produced by the asynchronous machine, aGossen wattmeter is to be used....
Starting procedure.        All the measurements devices are to be turned on. The ice bath reference for the        thermoc...
Where         is the pump consumption               is the flux side heat transfer over the whole evaporatorThe heat out f...
During the period of the tests, some refrigerant losses can occur. This can be caused byleaks at the expander level (which...
Expansion TankInstallation of an expansion tank at the exhaust of the pump. This tank has two goals:                      ...
Volume of Evaporator: It is assumed that ½ of the evaporator volume is filled with liquid.This assumption is arbitrary, th...
Upcoming SlideShare
Loading in …5
×

The study and modeling of organic rankine cycle

1,020 views
985 views

Published on

Published in: Design
0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
1,020
On SlideShare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
78
Comments
0
Likes
1
Embeds 0
No embeds

No notes for slide

The study and modeling of organic rankine cycle

  1. 1. The Study and Modeling of Organic Rankine Cycle (ORC)Drawback of using waterIn case of low temperature Rankine cycles, the boiling temperature is much lower and thewater/steam is not appropriate because of its low efficiency under these conditions. Water alsoshows a high specific volume on vaporization that imposes larger installationsAdvantages of ORC in Solar ThermalThe ORC allows a Lower collector temperature, a better collector efficiency (reduced ambientlosses) and hence the possibility of reducing the size of solar fields. The equipment is so smallerin size to produce small amounts of power.Organic Rankine cycle (ORC) is preferred as compared to other available technologies, becauseof its simplicity and its limited number of components, all of them being very common andcommercially available.Several examples of parabolic troughs using ORC are available in the literature: S. Canada presented a parabolic trough ORC Solar Power Plant, using n-pentane as working fluid and with an inlet temperature of 204 C [Canada, 2005]. E.H. Malick Kane, in his doctorate thesis, studied the integration of two superposed ORC on a parabolic though solar collector, the topping cycle using R-123 as working fluid, and the bottoming cycle using R-134a [Kane, 2002]Basic Idea 1. It is being used in Low grade heat recovery applications (e.g. Biological waste heat, engine exhaust gases, small scale cogeneration, domestic boilers, etc) and Solar Thermal Power Plants, 2. Working fluid is a refrigerant or hydrocarbonFactors to be considered 1. The efficiency of the cycle 2. Output shaft power 3. Cycle Limits 4. Refrigerant Charge: the quantity of Refrigerant in a Refrigeration System 5. Expander Selection 6. Refrigerant Selection
  2. 2. Working Fluids and their ComparisonsThe physical properties of the working fluid are of key importance and influence the behavior ofthe cycle.The vapor saturation curve in the T-s diagram can have a positive, negative or vertical slopeA small superheating at the exhaust of the evaporator will always be preferred which hasconsequences on the optimal thermodynamic properties of the fluid.The preferred characteristic for low temperature Rankine cycles is the isentropic saturationvapor curve (R11 in figure 3). Indeed, the saturation vapor curve is parallel to the line of theisentropic expansion and fits very well the cycle.Positive slope vapor saturation curve (isopentane in figure 3). The fluid has to be cooled downat the exhaust of the expander before entering the two-phase state. This can be done by theuse of a regenerator between the exhaust of the pump and the exhaust of the expander.In addition to the above T-s Chart, following factors must be considered during its selectionLow freezing point, high stability temperature
  3. 3. Organic fluids usually suffer chemical deteriorations and decomposition at high temperatures.The maximum hot source temperature is thus limited by the chemical stability of the workingfluid. The freezing point has to be lower than the lowest temperature in the cycle.High heat of vaporization and densityA fluid with a high latent heat and density will absorb more energy from the source in theevaporator and thus reduce the required flow rate, the size of the facility, and thepump consumption.Low environmental impactThe main parameters are the « Ozone depleting potential » (ODP) and « greenhouse warmingpotential » (GWP)SafetyThe fluid has to be non-corrosive, non-flammable, and non-toxic. The ASHRAE safetyclassification of the refrigerant is a good indicator of the dangerousness level of the fluid.Good availability and low costTraditional refrigerants used in ORC are expensive. This cost could be reduced by the use oflow-cost hydrocarbons.Acceptable pressuresVery high pressures have a negative impact on the reliability of the cycle. They lead to the needof more resistant and more expensive facilities.
  4. 4. R-22 and R-134a can be eliminated, their temperature range being too lowWater, benzene, toluene and p-xylene have a too high temperature range and can beeliminated as well
  5. 5. R-11 and R-113 have a very high ozone depleting potential (ODP), and were phased out in1996 by the Montreal protocolR-123, R-245fa, n-pentane and isopentane, each of them has its advantages and drawbacks: R-123 and R-245fa are non-flammable and isentropic, while n-pentane and isopentane have a higher vaporization heat, a lower GWP, and a much lower cost.According to some research simulations carried out, we have the following conclusions 1. One paper suggests that R-123 had a slightly better efficiency than isopentane 2. In another paper, the calculated efficiencies of R-123, R-245fa, R-134a and n-pentane were respectively: 9.71, 9.3, 7.86 and 9.74 % 3. 3rd Paper Suggestions: R-123 and n-pentane outperformed the other fluids (ammonia and PF5050) with a higher efficiency of 9.8 and 9.9 % respectivelyCycle SelectionDifferent types of cycles exist to achieve the above purpose which can involve reheat,intercooler, or regenerator. While selection of the above cycle(s), the priority are given to thefollowing Efficiency Specific Work; and SimplicityThe ORC efficiency can be improved by addition of a regenerator. Its use is justified when theslope of vapor saturation curve is positive.
  6. 6. Effect of Irreversibilities:The effect of irreversibilities in the cycle is a reduction of the cycle efficiency and useful workoutput. The main irreversibilities are: 1. Losses in the pump and in the expander (friction, leakage, etc) 2. Pressure drops in heat exchanger 3. Inefficiencies in the heat exchangerExpanders Types and ComparisonDistinction must be done between two main types of expanders: The turbomachines and thedisplacement type machinesTurbomachines have several drawbacks when used in low-temperature heat recoveryapplications: The performances of most rotary machines are related to their peripheral speed(or tip speed) U [m/s], rather than directly to the shaft speed. They have an optimal tip speed,usually independent from the machine size. For Positive Displacement this value rangestypically from 1 to 10 m/s, while for turbomachines, this value is close to 300 m/s.The tip speed is given by , R being the radius of the rotary machine.
  7. 7. When used in smaller units, the turbomachines have a lower radius R, and their optimalrotational speed is therefore increased. This very high shaft speed causes high mechanicalstresses (e.g. due to centrifugal loading), bearing friction losses, diminution of the bearing life,necessity for higher reduction gear, etc. In contrast, the tip speed of a displacement type machine is inherently lower, and the drawbacks presented above disappear. The pressure ratio of a single-stage turbomachine has a low value (typically 1.5), while the displacement machine can have as high pressure ratios as desired. This latter solution is hence preferred for the single-stage expansion usually used in the low temperature Rankine cycle. Volumetric machines are much more resistant to an eventual liquid phase in the fluid than turbines: their rugged design and their low rotational speed make them less sensitive to contamination by liquid droplets.In one paper, the scroll machine has been selected among all the displacement type machinesfor its reduced number of moving parts, reliability, wide output power range, and goodavailability. Compared to the piston compressor, the scroll also shows the advantage of nothaving admission valvesA few papers also present the Wankel engine and the screw expander as appropriatetechnologies for organic Rankine cyclesFactors to be considered in selection of a Positive Displacement Machine 1. Swept Volume 2. Internal built-in ratioThe Internal built-ratio has to be adapted to the range of pressure ratios imposed to theexpander.Disadvantages of LeakagesThe leakage reduces the output power of a machine working as expander, as the fluid flowsdirectly from the high pressure region to the low pressure region without producing any usefulwork.Lubrication of Expander
  8. 8. Expanders may be lubricated or not. Lubrication reduces the friction between the relativemoving parts and reduces the leakage area. However, modifying a lubricated compressor intoan expander raises several problems: The rotation taking place in the opposite direction, the oil pump might not work anymore if it is directly connected to the shaft of the compressor. In this case, a separate oil circuit has to be added. The compatibility of the working fluid with the lubricating oil is not guaranteed if the compressor has not been designed for ORC fluids.In order to cope with these problems the scroll machine must be an oil-free compressor.Positive Displacement Expander Types and Their ComparisonThe scroll expander is a positive-displacement machine. The expander prototype can be anoil-free air scroll compressor adapted to be run in expander mode. It can be isolated andby-passed thanks to 3 bulb valves, in order to start the test in appropriate conditions.Advantages of a scroll compressorThe scroll compressor is very widespread in refrigeration applications. It has fewer movingparts than reciprocating compressors, which improves its reliability and reduces the soundpollution. Scroll compressors are known to be very compact and to operate very smoothly, astheir vibration level is limited.Types of leakage in a scroll compressor:
  9. 9. The flank leakage is due to the clearance between the flanks of the two scrolls, and the radialleakage is due the clearance between the tip of one scroll and the plate of the other oneIn order to reduce leakages, two types of seals must be embedded in the scroll compressor: An internal seal, nettled in the tip of both scrolls. Its role is to reduce the radial leakage. A circular peripheral seal, located on the fixed scroll, whose role is to isolate the inside of the scroll from the outside and to avoid either external infiltrations or leakages to the outsideOverview of components and measurement devicesExpander is coupled to an asynchronous machine by means of a torque-meter andbelt-and-pulley couplings. An asynchronous machine is chosen for its ability to impose therotational speed to the expander. The most ubiquitous example being the common ACinduction motor which must slip to generate torque.The condenser may be air cooled. The liquid condensate leaving the condenser is then pumpedtowards the higher pressure boiler.
  10. 10. PumpPump can be a hydraulic diaphragm type pump. In it the piston transmits the power to the fluidby the intermediary of a flexible membrane (hydraulic diaphragm). There is therefore nocontact between the fluid and the piston, which allows the use of abrasive or corrosive liquids.The check valves are composed of an INOX ball that blocks the fluid during the admission orcompression stroke. This type of pump is designed to ensure accuracy and is engineered forcontinuous metering. Its applications are in the field of water treatment and petrochemicalengineering.Note: R-123 working fluid is very corrosive with synthetic materialsCondenserThe condenser is composed of plate heat exchangers. Plate heat exchangers are made of astack of corrugated plates gasketed or brazed together (see Figure 10).
  11. 11. They have a major advantage over conventional heat exchangers in that, the fluids being spreadout all over the plates, they are exposed to a much larger surface area. These exchangers aretherefore very compact.It should be selected as such that there must be lowest possible pressure drops. This can bedone by installing heat exchangers in parallel rather than series if more than one requiredConfiguration for installationThe condenser was composed of two or three plate heat exchangers assembled in series andone-pass mode. This configuration having high pressure drops, it was changed to two heatexchangers associated in parallel for the second set of tests.Drain cockIn order to remove the air that may have leaked into the cycle while it is not running, a draincock is installed at the exhaust of the pump. The air is purged every time before starting thecycle.Asynchronous machineThe electricity generating device must be 40W asynchronous motor which must be connectedto the electric circuit and its output power to be measured. However, if the machine isoversized, it might not have an optimal efficiency. But it would not constitute a problem, sincethe shaft power is also supposed to be measured right after the expander by means of a torquemeter.EvaporatorThe evaporator is composed of Parabolic Troughs and Vacuum TubesMeasurement devicesThermocouplesVarious types of thermocouples are available:Factors to be considered in selection of thermocouples: Temperature Range Sensitivity Tolerance
  12. 12. The thermocouples of Type-T (Copper/Constantan), with a tolerance “class 1” are suitable formeasurements in the −200 to 400 °C range. Type T thermocouples have a sensitivity of ~43µV/°C. This tolerance is the tolerance over the absolute temperature given by thethermocouple with the 0°C reference.When used to measure a temperature difference between two points with two differentthermocouples and the same reference, the tolerance is evaluated to 0.2 K.All the thermocouples are put in elbows, in order to reduce the conduction parasitic heat fluxand the error linked to it. The thermocouples are not calibrated, this operation being quitecomplex because its high cost and of the tools required (high resolution multimeter, benchmark,etc.).Pressure measurementThe pressure measurements are performed by differential transducers and pressure sensors.Differential transducersTwo differential transducers are to be used: one for measuring the pressure differential overthe expander and the other to determine the air flow rate by means of the standard nozzle.Accuracy of these pressure transducers is ±0.5% full scale.Pressure sensorsPressure sensors are used to measure the pressures at expander supply and exhaust.Torque meterIn order to measure the expander mechanical power, a torque meter is installed between theexpander and the asynchronous machine. The accuracy on the measurement of the torque is tobe known. A proximity sensor also measures the rotational speed of the torque meter shaft.The mechanical power is calculated by:ηcour being the efficiency of the transmission belt.Wattmeter
  13. 13. In order to measure the amount of electrical energy produced by the asynchronous machine, aGossen wattmeter is to be used.Acquisition cardsThe variables are to be recorded using a ADC connected PC system with a known sampling rate.The measured value is a DC voltage coming from the pressure and power sensors. Thesensitivity for the range of voltage is also to be known along with accuracy.Flow Meter typesCoriolis flow meterThe Coriolis flow meter, also known as mass flow meter, is a device that measures how muchfluid is flowing through a tube. It does not measure the volume of the fluid but the amount ofmass flowing through the device.The advantages of the Coriolis flow meter over traditional flow rate measurement devices arethe following: Highly accurate and repeatable flow rate measurement (typically from 0.05 to 0.5 %). Auto calibration : no calibration or zero point research is needed, as everything is done by the transmitter. Reduced maintenance : since there are no moving parts, the durability of the device is very good, it only needs to be cleaned from time to time. Ability to measure the fluid density or temperature, in addition to the flow rate.There are two basic configurations: the curved tube flow meter and the straight tube flowmeter.The straight tube flow meter is more accurate, and remains accurate even under changingdensities of process fluid, external vibration and mounting stresses. It is also more expensive.Testing ProcedureA preliminary test must be carried out in order to evaluate the leakage area: theexpander is connected to a pressurized air tank, whose pressure is initially 4 bars. Thetime evolution of the pressure inside the tank is measured and allows the evaluation ofthe leakage from the inside of the expander through the peripheral seal.The main difficulty which is normally faced this tests is the lack of flow meter on therefrigerant side.
  14. 14. Starting procedure. All the measurements devices are to be turned on. The ice bath reference for the thermocouples is to be set. The acquisition of the data is then started. The two valves isolating the expander are closed, the bypass valve is opened. The pump is switched on. The working fluid circulates in the cycle a few minutes before any further operation. The heat source (parabolic collector) is activated As the pressure increases in the cycle, the air that may have entered the cycle is purged at the drain cock. When the refrigerant temperature reaches approximately 100 °C at the exhaust of the evaporator, the expander is started: this is achieved by opening progressively the two isolating valves at the inlet and at the outlet of the expander, and by slowly closing the bypass valve. When the speed of the asynchronous machine reaches approximately 1500 rpm, the switch is turned on to connect the machine to the electric grid.Parameters to considered during testsParameter Minimum Value Maximum ValueSolar Heat FluxEnviroment TemperaturePressure ratio at the expanderRefrigerant flow rateRefrigerant flow rateCycle efficiencyExpander isentropic effectivenessCarnot efficiencyExergetic efficiencythe expander rotation speedThe output shaft power is calculated by :Where is the measured power at the torque meter is the transmission belt efficiencyAnd the cycle efficiency is calculated by :
  15. 15. Where is the pump consumption is the flux side heat transfer over the whole evaporatorThe heat out from the condenser is of key importance and there must some methodoly derivedin order to measure it if it is exposed to the air. Otherwise if the condenser is water-cooled thewater can be deviated to a water tank mounted on a very accurate balance (sensitivity100 gr). The time to fill the tank with 100 kg of water must be measured and hence theflow rate is deduced. These measurements also permit the calibration of the water flowmeter.An electricity counter can be added to measure the pump electrical consumptionThe modification of the expander rotational speed can be achieved by modifying thediameter of the pulley on the expander shaft. The expander speed is proportional to thediameter of the pulley. This modification can obviously not be performed while the cycleis working. A complete stopping of the expander is necessary before changing thepulley. A frequency inverter could be used to vary the rotational speed in a simpler way.the output shaft power is decreased when working fluid flow rate is lower if the pump isnot able to impose the flow rate, and less heat is recovered from the hot source.Refrigerant flow rateThe refrigerant flow rate is imposed by the pump. The fluid is in liquid state at theexhaust of the condenser and is incompressible. Therefore, its flow rate dependsdirectly on the volumetric flow rate of the pump. A metering pump can be used to adjustthis volumetric flow rate with an acceptable accuracy.If the condenser is water cooled. It can also be calculated from the heat balance overthe condenser. It is thus necessary to measure the water flow rate and the temperatureswith a good accuracy.Uncertainties must also be taken into accountThe possible origins for the unexpected flow rate are : A pump malfunction Pump cavitation during the aspiration of the fluid Presence of air in the cycleIf there is really presence of cavitation, it might be correlated to a diminution of thesubcooling at the exhaust of the condenserThe value of the subcooling is given by :Refrigerant losses
  16. 16. During the period of the tests, some refrigerant losses can occur. This can be caused byleaks at the expander level (which is not hermetic) or elsewhere in the cycle.The hypothesis of refrigerant losses is corroborated by the emptying of the cycle afterthe test series.Validation of the modelsModels must be validated, but with an almost constant working fluid flow rate, and smallvariations of the other parameters. It is necessary to validate these model on a widerrange of parameters.The cycle efficiency can be increased paying attention to the following parameters: Reduction of the condenser pressure drops and subcooling. Oversizing of the evaporator. Enhancement of the expander volume ratio, and reduction of the friction torque and of the leakage areaA very important parameter that needs to be controlled and optimized is the refrigerantflow rate.Only a limited number of “physical” parameters is accessible in order to achieve thoseimprovements : The subcooling can be controlled by modifying the refrigerant charge. (How??) The flow rate can and should be controlled by the pump.The ambient losses are detrimental to the heat balances, and no control of therefrigerant charge is possible.The following modifications must be performed in order to improve the behavior of thetest bench:The heat exchangers, the pipes and the expander must be completely insulated in orderto reduce the ambient losses. This operation is performed to improve the quality of theheat balances over each element, and to improve the efficiency of the cycle by reducingthe heat losses. The insulating material can be an elastomeric rubber insulation, with athickness of 13 mm and a 0°C conductivity of 0.036 W/(mK).
  17. 17. Expansion TankInstallation of an expansion tank at the exhaust of the pump. This tank has two goals: The first goal is to absorb the variations of the refrigerant flow rate due to the volumetric piston pump in order to make its measurement possible. This measurement is indeed limited by the acquisition frequency of the system. If the acquisition system has a too low acquisition frequency, it will result in irregular variations in the measured flow rate. The role of the expansion tank is to absorb the variations and to smooth the flow rate curve. The second role of the tank is to allow the modification of the refrigerant charge in the cycle: the tank is hanged to a piezoelectric force transducer that measures the weight of the tank and thus the amount of refrigerant in the device. The expansion tank is half-filled with refrigerant and the other half is filled with nitrogen under pressure. The lower end is connected to the exhaust of the pump and the upper end is connected to a gas cylinder that allows the adjustment of the pressure. If more fluid is required in the cycle, the nitrogen pressure is increased and the level in the tank lowers. A valve is added in the circuit downstream to the expansion tank, to increase the pressure drop when required. Increasing this pressure drop will increase the absorption of the flow rate variations by the expansion tank.Refrigerant charge calculationAs the circuit is initially completely empty, an evaluation of the refrigerant charge isneeded.The volume of each element has to be calculated. The regions of the cycle where thefluid is in vapor state are not taken into account, the density of the vapor beingnegligible compared to that of the liquid.The volumes taken into account are the following:Volume of the pump. For example if the pump is a reciprocating one, it is evaluated bythe product between the area of the piston and the stroke length:Volume of the piping The tubes concerned are the tubes between the outlet of thecondenser and the inlet of the evaporator.
  18. 18. Volume of Evaporator: It is assumed that ½ of the evaporator volume is filled with liquid.This assumption is arbitrary, the purpose being only to put enough refrigerant in order tofill the circuit. The adjustment of the refrigerant charge to get the desired level is doneby adding or removing refrigerant during the test.The volume is thus expressed by:Volume of the condenser: The approach is the same than for the evaporator. In thiscase, it is assumed that ¾ of the condenser is filled with liquid.The amount of refrigerant that needs to be introduced in the circuit is given by:The refrigerant charge to introduce in the circuit is 9% higher than calculated in order totake into account the refrigerant mass in vapor state and the possible refrigerant lossesduring the transfer.Expansion tank mathematical model.A simulation of the expansion tank is performed in order to calculate the minimumvolume required to get a good smoothing of the flow rate curve.

×