We delight with pleasure to introduce our Company M/s Mini Engineering Works having registered office at F285, UPSIDC, Khichra Industrial Area, Meerut-Gulawati Road, Ghaziabad in North India. The company mostly engaged with the power sector and acknowledges the prompt and result oriented services adopting the latest technology.
We very recently established a Setup of Manufacturing Plant of High Voltage Power Products of Measuring & Protection Instrument Transformers, from this Year i.e. November’2013.
OUR PRODUCTS ARE:
1. RESIN CAST CT RING TYPE AND 3 PHASE CT BANK TYPE UPTO 440V/660V
2. RESIN CAST CT UPTO 33KV
3. RESIN CAST PT UPTO 33KV
4. COMBINED CTPT UNITS UPTO 33KV
5. OIL COOLED CTs UPTO 33KV
6. OIL COOLED PTs UPTO 33KV
7. PILFER CTPT METERING CUBICLE UPTO 33KV
8. RESIN CAST RVTs
9. OIL COOLED RVTs
Our CTs/PTs are type tested from Govt. Laboratory ERDA, Vadodara.
Apart from Manufacturing Instrument Transformers upto 33KV, Mini Engineering Works is also engaged in HEAVY FABRICATION ON TURNKEY BASIS & Manufacturing of ENCLOSURES / DISTRIBUTION BOARDS viz.
1. Complete Fabrication of CTs & PTs tanks upto 220KV as per drawings.
2. LT DISTRIBUTION BOXES, 25KVA to 315KVA with Kitkat fuse / MCCB as per drawing
3. METER BOXES as per drawing
4. TRANSFORMER PROTECTION BOXES 25KVA as per drawing
5. MCB Distribution Boxes (4 or 6 Way Single Door TPN)
6. MCB Distribution Boxes (4 or 6 Way Double Door TPN)
We are ROHS (ISO) Certified Company. We are also registered with SSI, NSIC.
Apart from the above Manufacturing of CTs & PTs upto 33KV, we Channel Partner of
M/s Mehru Electrical & Mechanical Engineers Pvt Ltd, Bhiwadi
for the Supply of CTs & PTs above 33KV class and upto 400KV class.
Currently we are supply our CTs/PTs & Enclosures to Panel Builders, Construction Companies and till date we didn’t receive any complaint from our any client. Our CTs/PTs and Enclosures are working satisfactorily.
We have very good contacts with EPC Contractors/Electrical Contractors/PSU Units/Boards/Nigams. We have maintain Quality while production of Instrument Transformers. Every time, we will developed a strong clientele by supplying high quality product to varying specifications
For more details please visit our website.
With best regards,
For Mini Engineering Works
Shokaut Ali / Sharafat Ali
+91-9313115696 / + 91-9868667484
Er. Akram - +91-9210927863
E-mail ID : mew.ctpt@gmail.com /luckyindiapowersolutions@gmail.com
website: http://www.ctpttransformer.com
http://www.luckyindiapowersolution.com
http://miniengineeringworks.tradeindia.com/
More than Just Lines on a Map: Best Practices for U.S Bike Routes
Manufacturer of CTs & PTs upto 33KV including RVT & MS Fabrication
1. An ISO 9001:2008 Certified Company
Mini Engineering Works
F-285, UPSIDC, Khichra Industrial Area,
Meerut-Gulawati Road,
Ghaziabad – 201001, UP, India
2. THE TOTAL POWER SOLUTIONS
We are glad to introduce ourselves as one of the leading manufacturer
of measuring and Protection in High Voltage and Extra High Voltage
Systems (Current Transformers and Potential Transformer).
OVERVIEW
MINI ENGINEERING WORKS, founded by Mr. SHOKAUT ALI and
Er. AKRAM SAIFI, supported
by a dedicated team of Engineers,
Technicians and Business people, committed to a Technology, best
quality products, has been in the field of P o w e r S e c t o r f o r m o r e t h a n
1 8 Y e a r s a n d n o w e s t a b l i s h e d a S e t u p o f Manufacturing state of
High Voltage Power Products, from this Year 2013, and as we have
already told above that both Mr. Sharafat Ali, Technical Professional
having more than 18 years of experience in Power Sector especially
Instrument Transformers Category. W e have very good contacts with
almost
all
EPC
Contractors /Electrical
Contractors/PSU
Units/Boards/Nigams. We have started supplying our products to Private Sectors
currently and very shortly we will get approvals from Boards/Nigams too. Every time,
We will d eveloped a strong clientele by supplying high quality product to
varying specifications.
Today, M/s MINI ENGINEERING WORKS is v e r y n e w t o t h e C o r p o r a t e s
b u t w e a s s u r e s o u r b e s t Q u a l i t y Pr o d u c t s i n a s ti p u l a t e d t i m e fr a m e .
M/s Lucky India Power Solutions, company is it’s Parent Company and is
well known to all the Corporates of Power Sector and the Company Supplies
Complete Substation Materials upto 400KV Class including Complete
Substation / Plant Automation System by SCADA, PLC.
FACTORY SET UP
MINI ENGINEERING WORKS has factory setup with well-equipped
laboratories, testing department with all facilities for production check for
raw material, semi finished product and final product.
Carpet area of the factory is 7500 sq.feet and office area 500 sq. feet.
MOTTO
Quality, customer satisfaction and regular improvement for better to best
Quality Products.
COMMITTED TO
•
•
•
Design, develop, manufacture and service quality products as per
customer requirement.
Carry out production as per the standard procedures.
Improvement in product and services
3. THE TOTAL POWER SOLUTIONS
As mentioned earlier, MINI ENGINEERING WORKS
is one
among those
organizations in India that provides total power solution forms under a single roof:
The products and the corresponding range follows:
MANUFACTURING OF INTRUMENT TRANSFORMERS UPTO 33KV
Sr.
No
DESCRIPTION OF ITEMS MANUFACURED
RESIN CAST CT RING TYPE AND 3 PHASE CT
1
RANGE
440V/660V
BANK TYPE
2
RESIN CAST C.T
Up to 33kV
3
RESIN CAST P.T.
Up to 33kV
4
COMBINE CTPT METERING SET (33kV, 22kV,
11kV)
OUTDOOR, SINGLE PHASE CURRENT
TRANSFORMERS
OUTDOOR, SINGLE PHASE POTENTIAL
TRANSFORMERS
Up to 33 kV
PILFER CTPT METERING CUBICLE
Upto 33KV
5
6
7
Up to 33 Kv
Up to 33 kV
TYPE TEST
Our all Products are type tested from Govt. Laboratory ERDA, Vadodara.
4. THE TOTAL POWER SOLUTIONS
DISTRIBUTION BOARDS
Apart from Manufacturing Instrument Transformers upto 33KV, Mini Engineering Works
is engaged in HEAVY FABRICATION & Manufacturing of DISTRIBUTION BOARDS
1.
Complete Fabrication of CTs & PTs tanks upto 220KV as per drawings.
2.
LT DISTRIBUTION BOXES, 25KVA to 315KVA with Kitkat fuse / MCCB as per
drawing
3.
METER BOXES as per drawing
4.
TRANSFORMER PROTECTION BOXES 25KVA as per drawing
5.
MCB Distribution Boxes (4 or 6 Way Single Door TPN)
6.
MCB Distribution Boxes (4 or 6 Way Double Door TPN)
5. LIST OF PLANT AND MACHINERY
Sr. No.
Name Of
Machine/Equipment
Brief Specification
Qty
1
Coil Drying Oven
Drying Oven
Temp.150
atmospheric pressure
deg
2
Drilling Machine
Vertical drilling
Capacity
with3/4”
3
Storage Bins & Racks
Industrial storage plastic bins &
M.S.Racks to stores material
4
H.V.Coil winding machine
(Motorized)
Machine
at
Axial winding machine with maximum
250 mm & axial Width 300mm Suitable
Up to 42 swg
Axial winding machine with maximum
250 mm & axial Width 300mm Suitable
Upto 22 swg Copper wire
1 No
2 Nos
3 Nos
2 Nos
5
L .V. Coil winding
machine (Motorized)
6
H.V.Coil winding machine
(Hand winding)
Axial winding machine with maximum
100mm & axial Width 120mm Suitable
Upto 42 swg Copper wire
2 Nos
Bench voice
12”jaw opening bench voice
2 Nos
8
Hand drill machine
10 mm bore capacity
2 Nos
9
Welding transformer
2 phase, capacity of 250 mm weld
current
2 Nos
10
Tooling Kit
7
2 Nos
Brazing unit
Various tools for general purpose allen
keys, spanner sets
&Other instruments
150 Amp brazing Current
Air compressor
For painting and finishing of work
13
Bending Machine
Suitable For Fabrication Bending Of
Sheet Metal Of Thickness 5 Mm
2 Nos
14
Shearing Machine
Suitable For Fabrication Cutting Of
Sheet Metal Of Thickness 5 Mm
2 Nos
15
Grinding Machine
For De Baring Of Metal Fabrication
3 Nos
16
Welding Machine
Welding Of Ms Metal Purpose
4 Nos
17
Oven
Heating Purpose
2 Nos
Furnace
Annealing of Core
4 Sets
1 No
11
12
18
1 No
1 No
6. LIST OF EQUIPMENTS FOR TESTING (INCLUDING INSPECTION OF
RAW MATERIALS)
Name Of
Machine/Equipment
Brief Specification
1
Combined CT Test System
for measurement of ratio
and phase angle error
Test system consisting Of test set
CT TEST BRIDGE FOR 5A & 1A
calibrated
1 Set
2
Burden Box
Burden Box Of 40 VA Of 5 A
Burden Box 40 VA Of 1 A
calibrated
1 Set
0-5-10-15-20-25-30-40-50-60-7580-100-125-150-200/5 AMP
calibrated
1 Set
Sr. No.
3
Calibration
status
Standard CT
0-5-10-15-20-25-30-40-50-60-7580-100-125-150-200/1 AMP
4
5
6
7
Combined PT Test System
for measurement of ratio
and phase angle error
Burden Box For PT
Standard PT’s
High frequency generator
set with control panel
8
High voltage AC Test
System
9
5 kV High voltage AC Test
System.
10
11
Qty
Set Of Voltmeter
Set Of Ammeter
1 Set
Test system consisting Of test set
PT Test Bridge
calibrated
Burden Box Of 105 VA Capacity
Of Output 110 Volts
calibrated
Burden Box Of 105 VA Capacity
Of Output 63.5 Volts
calibrated
Standard 11kV PT 1ø /2ø
Ratio: 11kV / 110V and 11Kv / rt3
/110V /rt3
Standard 22Kv PT 1ø /2ø
Ratio: 22Kv / 110V and 22Kv / rt3
/110V /rt3
Standard 33Kv PT 1ø /2ø
Ratio: 33Kv / 110V and 33Kv / rt3
/110V /rt3
Coupled motors with panel having
frequency
meter to get double voltage and
frequency for testing of PT’s
Test system consisting of HV test
transformer 80kv,
4kVA
continuous, control desk panel
with Ammeter, kV meter, and
tripping circuit of 20mA
1 Set
1 Set
1 Set
1 Set
calibrated
1 Set
calibrated
1 Set
calibrated
1 Set
calibrated
1 Set
Test system consisting of 0-5 kV
High voltage Transformer,
Manual voltage regulator
calibrated
Portable type precision type
voltmeter
RANGE: COM –75-150-300 VOLTS
RANGE; COM-150-300-600
VOLTS
Portable type precision type
voltmeter
RANGE: COM-5A-10A-25A-50A100A
RANGE: COM-500ma- 1A –5A
calibrated
1 Set
4 Nos
calibrated
4 Nos
7. LIST OF EQUIPMENTS FOR TESTING (INCLUDING INSPECTION OF
RAW MATERIALS)
Sr. No.
Name Of
Machine/Equipment
Brief Specification
Calibration
status
Qty
calibrated
12
Current Source
220V/0-1500 amps with suitable
taps and capacity of 3.5 kVA
13
Resistance Measuring
Bridge
4 Terminal Milli ohmmeter from
199.9 micro ohm to 19.9 kilo
Ohms
14
Polarity Meter
General Purpose Analog Meter
15
Voltage Regulator
0-415n Volts output
28A. Auto Transformer
input 415 volts 3 PHASE
16
Continuity Meter
General
Multimeter
17
Digital General purpose
Multimeter
General purpose Multimeter with calibrated
facilities of AC DC voltage
measurement,
Ammeters
Resistance Measurement
18
Megger Meter
5 kV MEGGER to measure
insulation resistance value
19
Clip – On Meter
MAKE MECO
0– 1000 Amp, 750 Volts
Purpose
1 Set
calibrated
1 No
calibrated
3 Nos
calibrated
2 Nos
Analog
calibrated
1 No
2 Nos
calibrated
2 Nos
calibrated
1 No
8. QUALITY SYSTEMS AND PROCEDURES
1. BROUGHT OUT ITEMS (RAW MATERIALS)
1.1. COPPER
- Maintaining Test Report for purchase from standard manufacturers
- Testing class of insulation of enamel covering by performing temperature test
- Electrical Breakdown Value (BDV) Test of enamel covering
- Maintaining records of each spool used for individual job
1.2. PAPER
- Maintaining Test Report for purchase from standard manufacturers
- Testing class of insulation by carrying temperature test
- Electrical Breakdown Value (BDV) Test
1.3. OIL
- Maintaining Test Report for purchase from standard manufacturers
- Electrical Breakdown Value (BDV) Test
1.4. CORE
- Maintaining Test Report for purchase from standard manufacturers
- Verifying the grade of material
- Checking of Knee Point Voltage (SATURATION OF CORE)
2. IN HOUSE TEST (SEMI FINISHED & FINISHED GOODS)
2.1. COIL
- Resistance Of Coil
- Maintaining records of coil used for each job
- Examining dimensional records of coil
- Maintaining records of worker, responsible for the winding
2.2. SEMI FINISHED & FINISHED GOODS
- Maintaining test report of SEMI FINISHED & FINISHED GOODS
- Analyzing the reports of failures in intermediate stages and taking corrective measures accordingly
- Analyzing the reports of failures in final stage and taking corrective measures accordingly
- Examining the final reports before dispatch
3. EQUIPMENTS
3.1. TEST EQUIPMENT & MACHINERIES
- Periodically calibrating and reconditioning of test equipment and machineries from standard
government and private labs, required for testing in the production process.
3.2. PERIODICAL MAINTENANCE OF PLANT AND MACHINERIES
4. TESTS
4.1. TYPE TEST
- Timely performing the type test of the manufactured product in N.A.B.L accribated labs like E.R.D.A
(Electronic Research and Development Association) and C.P.R.I (Central Power and Research
Institute).
9. PRODUCT PROFILE
CURRENT TRANSFORMER
APPLICATION –Direct measurement of current in high voltage & high current system is not possible because of
difficulty in electrical isolation of measuring instruments. Because of its high value,it is also not possible to use current flowing
directly to the system, so that current transformer are used to step down the high system current into low system measuring
current with their proportionate ratio. due to this it is possible to measure high system current by using standard measuring
instruments & relays, also its isolate meters,relays from high voltage systems.
VARIOUS TYPES OF CURRENT TRANSFORMERS
Ring Type Current Transformers : A Current Transformer which has an window
in the center to accommodate a primary conductor (busbar or cable) through it.
Bar -Primary Current Transformers : A Current Transformer in which the
primary winding consists of bar of suitable size and it is an integral part of the CT.
Wound Type Current Transformers : A Current Transformer having a primary
winding of more than one full turn wound on the core.
Interposing Current Transformers : These Current Transformers are used in
conjunction with main CTs to alter the ratio of main CT or to provide isolation to
meters or relays from main CTs secondary circuit. Primary current of these CTs
are generally lower than 1 0 amp. Due to which they are always wound primary
type.
Summation Current Transformers : W hen current flowing, in more than one
feeder is required to be metered summation current transformer are used. These
Current Transformers are provided with more than one primary winding and one
common secondary.
Bushing Type or Busduct Current Transformers : These Current
Transformers are Ring type construction & can be mounted on Busduct or
Bushing turrert of power transformer.
Core Balance Current Transformers : These are ring type Current
Transformers & suitable for the measurement of the sum of three phase currents
in a 3-ph cable. Under normal operating conditions this sum is zero. In the event
of an earth-fault the sum of the current is equal to the zero sequence current.
.
10. RESIN CAST CURRENT TRANSFORMER
RANGE – 11, 22 & 33 KV
ACCURACY CLASS – 0.2 & 0.5
SPECIAL ACCURACY CLASS – 0.2S & 0.5S
IS : 2705
Technical Specification As Per IS : 2705
General Particulars
11KV
22KV
33 KV
Highest System Voltage( H.S.V.)
12 KV ( r.m.s.)
24 KV ( r.m.s.)
36 KV (r.m.s.)
Power frequency dry/ wet withstand
28 KV ( r.m.s.)
50 KV ( r.m.s.)
70 KV ( r.m.s.)
voltage on primary winding for one
minute
Lightning Impulse withstand voltage
75 KV ( r.m.s.)
125 KV ( r.m.s.)
170 KV ( r.m.s.)
(1.2 x 50 µ s )
PD measuring Voltage / Permissible
7.6/50
15.2/50
23.0/50
Voltage
Specific Particulars
Rated Transformation Ratio
As per customer requirement (in Amp.)
Rated Primary Current
Upto 2000 Amp.
Rated Secondary Current
1 Amp. 5 Amp. 0.577 Amp.
As per customer requirement.
In general CT is to be specified with STF of 100 for 1 Sec.
Short Time Thermal Current (Ith)
or STC (lth) equal to the system fault level whichever is
lower. KA ( r.m.s. )
Short Time Dynamic Current
2.5 X Ith KA (Peak)
Number of Cores
Upto 3 cores
Output Burden
Upto 60VA, 0.8 pf Lagging
For Metering :
0.2S, 0.2, 0.5S, 0.5, 1.0 & 3.00.
Accuracy Class
For Protection:
5P, 10P, 15P & PS
IAF, ALF, Knee Point Voltage,
As per customer requirement / Design Constraints
Exciting Current & Resistance
Type of construction
As Per Panel Conditions(Customer Requirement)
11. OIL COOLED CURRENT TRANSFORMER
Technical Specification As Per IS : 2705
General Particulars
11KV
22KV
33 KV
66 KV
Highest System
12 KV ( r.m.s.)
24 KV ( r.m.s.)
36 KV (r.m.s.)
72 KV (r.m.s.)
Voltage( H.S.V.)
Power frequency dry/
wet withstand voltage
28 KV ( r.m.s.)
50 KV ( r.m.s.)
70 KV ( r.m.s.)
150 KV ( r.m.s.)
on primary winding
for one minute
Lightning Impulse
75 KV ( r.m.s.)
125 KV ( r.m.s.)
170 KV ( r.m.s.)
350 KV ( r.m.s.)
withstand voltage (1.2
x 50 µ s )
Specific Particulars
Rated Transformation
As per customer requirement (in Amp.)
Ratio
Rated Primary Current Upto 2000 Amp.
Rated Secondary
1 Amp. 5 Amp. 0.577 Amp.
Current
As per customer requirement.
Short Time Thermal
In general CT is to be specified with STF of 100 for 1 Sec. or STC (lth) equal
Current (Ith)
to the system fault level whichever is lower. KA ( r.m.s. )
Short Time Dynamic
2.5 X Ith KA (Peak)
Current
Number of Cores
Upto 5 cores
Output Burden
Upto 60VA, 0.8 pf Lagging
For Metering :
0.2S, 0.2, 0.5S, 0.5, 1.0 & 3.00.
Accuracy Class
For Protection:
5P, 10P, 15P & PS
IAF, ALF, Knee Point
As per customer requirement / Design Constraints
Voltage, Exciting
Current & Resistance
Type of construction
Dead / Bottom Tank or Live / Top Tank
12. POTENTIAL TRANSFORMER
APPLICATION – Direct measurement of voltage in high voltage & high current system is not possible because of
difficulty in electrical isolation of measuring instruments. Because of its high value, it is also not possible to use voltage
directly to the system, so that Potential transformer are used to step down the high system voltage into low system
measuring voltage with their proportionate ratio. due to this it is possible to measure high system voltage by using
standard measuring instruments & relays, also its isolate meters, relays from high voltage systems and also to sense
abnormalities in voltage & give signal to protective relay to isolate the defective system.
RESIN CAST POTENTIAL TRANSFORMER
RANGE – 11, 22 & 33 KV
ACCURACY CLASS – 0.2 & 0.5
SPECIAL ACCURACY CLASS – 0.2S & 0.5S
IS : 3156
Technical Specification As Per IS : 3156
General Particulars
Highest System Voltage( H.S.V.)
Power frequency dry/ wet withstand
voltage on primary winding for one
minute
Lightning Impulse withstand Voltage (
1.2 x 50 µ s )
PD measuring Voltage / Permissible
Voltage
Specific Particulars
Number of Phases
Rated Transformation Voltage Ratio
Number of Secondary Windings
Output Burden
Accuracy Class
Voltage Factor
11KV
22KV
33 KV
12 KV ( r.m.s.)
24 KV ( r.m.s.)
36 KV (r.m.s.)
28 KV ( r.m.s.)
50 KV ( r.m.s.)
70 KV ( r.m.s.)
75 KV ( r.m.s.)
125 KV ( r.m.s.)
170 KV ( r.m.s.)
7.6/50
15.2/50
23.0/50
3 or 1 unearthed or earthed
As per customer requirement
Upto 3
Upto 100VA
For Metering : 0.2, 0.5 & 1.0
For Protection: 3P, 6P
1.2 Continuous & 1.5 for 30 Sec or 1.9 for 30 Sec or 1.9 for
8 hours
13. 0IL COOLED POTENTIAL TRANSFORMER
OIL COOLED POTENTIAL TRANSFORMERS
Technical Specification As Per IS : 3156
General Particulars
Highest System
Voltage( H.S.V.)
Power frequency
dry/ wet withstand
voltage on primary
winding for one
minute
Lightning Impulse
withstand Voltage (
1.2 x 50 µ s )
Specific Particulars
Number of Phases
Rated
Transformation
Voltage Ratio
Number of
Secondary Windings
Output Burden
Accuracy Class
Voltage Factor
11KV
22KV
33 KV
66 KV
12 KV ( r.m.s.)
24 KV ( r.m.s.)
36 KV (r.m.s.)
72 KV (r.m.s.)
28 KV ( r.m.s.)
50 KV ( r.m.s.)
70 KV ( r.m.s.)
150 KV ( r.m.s.)
75 KV ( r.m.s.)
125 KV ( r.m.s.)
170 KV ( r.m.s.)
350 KV ( r.m.s.)
3 or 1 unearthed or earthed
As per customer requirement
Upto 3
Upto 500VA
For Metering : 0.2, 0.5,1.0 & 3.0
For Protection: 3P, 6P
1.2 Continuous & 1.5 for 30 Sec or 1.9 for 30 Sec or 1.9 for 8 hours
14. COMBINED CTPT SET
APPLICATION- Combined CTPT Metering Units that are available up to 33 kV class are manufactured specifically to
meet the needs of Electricity Supply and captive generating units. The C.T.-P.T. metering sets of this type as the name
suggests are used for measurement of power on high voltage side. The C.T.-P.T. sets are installed before the main
transformer and the main line goes through C.T.-P.T. set to the main transformer. Metering equipment is connected to the
secondary side of the C.T.-P.T. set. As the accuracy of the C.T.-P.T. set is high & as it is connected before the transformer,
measurement of power is much more accurate compared to the metering done on L.T. side, the transformer losses are
also included in the measurement.
OIL COOLED CTPT SET
RESIN CAST 3 Ø PT
Technical Specification For Oil Cooled CTPT Set As Per IS:2705 & IS:3156
General Particulars
Highest System Voltage( H.S.V.)
Power frequency dry/ wet withstand
voltage on primary winding for one
minute
Lightning Impulse withstand Voltage (
1.2 x 50 µ s )
System Particulars
3 Phase 4 Wire with Isolated / Floating
neutral as well as solidly earthed.
3 Phase 4 Wire with Isolated / Floating
neutral as well as solidly earthed.
Specific Particulars
Short Time Thermal Current (Ith)
Output
Accuracy Class
Secondary Current (CT)
Secondary Voltage (VT)
Primary Current (CT)
Primary Voltage (VT)
11KV
22KV
33 KV
12 KV ( r.m.s.)
24 KV ( r.m.s.)
36 KV (r.m.s.)
28 KV ( r.m.s.)
50 KV ( r.m.s.)
70 KV ( r.m.s.)
75 KV ( r.m.s.)
125 KV ( r.m.s.)
170 KV ( r.m.s.)
3 Nos. CTs & 1 No. 3 - Phase PT
2 Nos. CTs & 1 No. 3 - Phase PT
As per customer requirement.
In general CT is to be specified with STF of 100 for 1 Sec.
or STC (lth) equal to the system fault level whichever is
lower. KA ( r.m.s. )
10 VA to 100 VA for PT and 5 VA to 30 VA for CT
0.2S, 0.2, 0.5S, 0.5, 1.0 for CT. and 0.2, 0.5 & 1.0 for PT
1 Amp or 5 Amp
110 Ph-Ph or 110/v3 V, Ph-Neutral
As per customer requirement.
11KV, 22KV, 33KV for 3-Phase PT
11/v3, 22/v3, 33/v3 for 1-Phase PT
15. Technical Specification For resin cast CTPT Set As Per IS:2705 & IS:3156
General Particulars
Highest System Voltage( H.S.V.)
Power frequency dry/ wet withstand
voltage on primary winding for one
minute
Lightning Impulse withstand Voltage
( 1.2 x 50 µ s )
PD measuring Voltage / Permissible
Voltage
System Particulars
3 Phase 4 Wire with Isolated / Floating
neutral as well as solidly earthed.
3 Phase 4 Wire with Isolated / Floating
neutral as well as solidly earthed.
Specific Particulars
Short Time Thermal Current (Ith)
Output
Accuracy Class
Secondary Current (CT)
Secondary Voltage (VT)
Primary Current (CT)
Primary Voltage (VT)
11KV
22KV
33 KV
12 KV ( r.m.s.)
24 KV ( r.m.s.)
36 KV (r.m.s.)
28 KV ( r.m.s.)
50 KV ( r.m.s.)
70 KV ( r.m.s.)
75 KV ( r.m.s.)
125 KV ( r.m.s.)
170 KV ( r.m.s.)
7.6/50
15.2/50
23.0/50
3 Nos. CTs & 1 No. 3 - Phase PT
3 Nos. CTs & 3 Nos. 1 - Phase PT
2 Nos. CTs & 1 No. 3 - Phase PT
2 Nos. CTs & 3 Nos. 1 - Phase PT
As per customer requirement.
In general CT is to be specified with STF of 100 for 1 Sec.
or STC (lth) equal to the system fault level whichever is
lower. KA ( r.m.s. )
10 VA to 100 VA for PT
5 VA to 30 VA for CT
0.2S, 0.2, 0.5S, 0.5, 1.0 for CT.
0.2, 0.5 & 1.0 for PT
1 Amp or 5 Amp
110 Ph-Ph or 110/v3 V, Ph-Neutral
As per customer requirement.
11KV, 22KV, 33KV for 3-Phase PT
11/v3, 22/v3, 33/v3 for 1-Phase PT
16. Low Tension Pilfer Resistant Metering Cubicle
Types:-
Features:-
Application:-
L.T to 33 KV Voltages Class
1/2/3 one to Five core available
Various outline Size as per Customer requirement
Bar and Wound primary Type
Compact in design, Low cost and maintenance free.
Used mainly for outdoor LT metering on poles.
Separate Meter compartment and CT compartment.
CT's are epoxy molded to avoid any pilferage.
CT's are provided with various inner diameter according to requirement of cable size.
Complete dust & vermin proof confirming to IP55 with locking and sealing arrangement..
No secondary circuit wires are accessible outside which avoids chances of energy theft.
Stable accuracy over life time.
Provision of installing modem inside the cubicle provided
Non hygroscopic CT's.
Precision check metering, control indication...
Largely used for Metering of LT consumers .
Specification
SL.
1
2
3
4
Particulars
Type of Box
Type of CT
Operating System Voltage
Power Frequency Dry
withstand Voltage
5 Transformation ratio
6 Rated Secondary Current
7 Fault Level of CT
8
No of CT
9 Output Burden
10 Accuracy class
Unit
V
KVp(rms)
Amp
Amp
KA
no
VA
-
Description
Sheet Metal or SMC
Epoxy Resin Cast Bar Primary L.T.C.T
230 , 440
3 to 6
50 to 1200 or as per requirement
5.0
upto 6 KA for 1 or 3 sec
4 Nos for 3Phase 4Wire System
3 Nos for 3Phase 3Wire System
Upto 30 at 0.8 pF lag.
17. EPOXY RESIN CAST PILFER RESISTANT METERING CUBICLE/PANEL
Types:-
Features:-
Application:-
11KV to 33KV Voltage Class
3 no C.T's & 3 No Single Phase VT'S
3 no C.T's & 1 No Three Phase VT'S
Compact in design, Low cost and maintenance free.
Separate Meter compartment and CT-PT compartment.
Available in 3Phase 3Wire and 3Phase 4Wire systems.
CT's & PT's are epoxy molded to avoid any pilferage.
Complete dust & vermin proof confirming to IP55 with locking and sealing
arrangement.
No secondary circuit wires are accessible outside which avoids chances of energy
theft.
Stable accuracy over life time.
Designed mainly for Indoor applications
Non hygroscopic CT's & PT's.
Precision Revenue metering, control indication.
Used for Double Metering of Transformers.
Used on Feeder Metering for energy accounting.
Specification
SL.
1
2
3
4
5
6
7
8
9
10
11
12
Particulars
Highest System Voltage
Power Freq dry/wet withstand voltage
Lightning Impulse Voltage 1.2/50 µs
Partial Discharge Measuring Voltage/ Limit.
Transformation ratio
Rated Primary Current
Rated Secondary Current
Rated Secondary Voltage
Rated Secondary Current
Short Time Current Rating
Out put Burden
Accuracy class
For CT
For VT
kV
KVp rms
KVp
KV/pC
Amp
Amp
Amp
Volts
Amp
KA(rms)
VA
-
11 KV
15 KV
22 KV
33 KV
12
17
24
36
28
36
50
70
75
110
125
170
7.6KV/50pC 10.8KV/50pC 15.2KV / 50pC 23KV / 50pC
As per customer requirement.
Upto 1000 Amp
1.0, 5.0
110/√3 for Ph-Neutral, 110 for Ph-Ph
1.0, 5.0
Upto 25KA for 1 or 3 sec
Upto 30 at 0.8 pf lag for CT
Upto 100 at 0.8 pf lag for PT
0.2, 0.2s, 0.5, 0.5s, 1.0, 3.0 & 5.0
0.2, 0.5, 1.0
18. Office address :
F-285, UPSIDC, Khichra Industrial Area,
Meerut-Guwahati Road,
Ghaziabad – 201001, UP, India
Phone No. : +91-9210927863 / +91-9313115696/ +91-9868667484
E-mail ID : mew.ctpt@gmail.com /
luckyindiapowersolutions@gmail.com / info@luckyindiapowersolution.com
Contact Details :
Mr. Shokaut Ali / Mr. Sharafat Ali
Phone No. : +91-9313115696 / + 91-9868667484
E-mail ID : mew.ctpt@gmail.com /
luckyindiapowersolutions@gmail.com / info@luckyindiapowersolution.com
Mr. Akram Saifi
Phone No. : +91-9210927863
E-mail ID : mew.ctpt@gmail.com /
luckyindiapowersolutions@gmail.com / info@luckyindiapowersolution.com