Cooling


 Rittal Cooling Application Guide



CRAC and Chiller Systems up to 118 kW
IT chillers and CRACs in conjunction with freecooling ensure efficient cooling and supply of the cooling medium.
Safety-relevant options such as redundant pumps, emergency cooling and buffer stores ensure maximum operational
reliability and fail-safeness.


LCP T3+ Maximum reliability with redundant cooling and power up to 24 kW
At the heart of the LCP T3+ are two embedded cold water circuits, each of which supplies 100% of the nominal cooling
output. The power supply to the fans also has a completely redundant layout.


LCP Plus - High density rack cooling up to 30 kW
Air/water heat exchanger, bayable with server racks based on TS 8. Complete unit with 30 kW useful cooling output.
The separation of cooling and rack prevents the ingress of water into the server rack, making it easy to assemble and very
service-friendly.


LCP Inline - Modular Liquid cooling up to 60 kW
Based on the LCP Plus design the air is delivered directly into the cold aisle rather than the rack. With superior resilience
modularity it is a perfect cooling method for cold aisle and hot aisle containment systems.


Vertical ventilation up to 3 kW
Ventilation base/plinth, roof vent and slotted component shelves ensure effective heat dissipation.


Horizontal ventilation up to 5 kW
A high air throughput, stylish design and outstanding security are provided by the perforated doors
(with 82% open area per door).


Hot Aisle Containment up to 10 kW
Separates the hot air from the cold. Utilising in line coolers the hot air is extracted and cooled to provide cold air to the front
of the server.


Cold Aisle Containment up to 10 kW
Traps the incoming cold air in front of the server inlets. Can either use inline cooling or CRACs to provide the cold air.


LCP Passive Retro-fittable cooling up to 20 kW
Perfect for dealing with any hot spots with in the Data Centre




section09 - 51                                                                               Rittal IT-Power, Cooling & The Enviroment 2011   Rittal IT-Power, Cooling & The Enviroment 2011   section09 - 52
Cooling                                                                                                                                                                                 Cooling



    Fan Trays

    When an excessive build up of heat occurs, fan trays are an excellent way to remove the
    warm air from the racks.


    All Rittal fan trays can be fitted during configuration or alternatively retro-fitted without any               TS 8 Top Fan Tray
    disruption to the equipment within the rack.

     Description	                                                           Model No. 	
     2-way 19” Rack mounted fan tray 1 U 		1-3 7027504
     TE 7000 four-way top mounted fan tray 		1-3 7001001 	
     TS 8 four-way fan tray for 800 x 800 and 600 x 1000 (grey) 		1-3 7537671 	
     TS 8 four-way fan tray for 600 x 600, 600 x 800 and 800 x 600 (grey) 		1-3 7537670 	
     TS 8 four-way fan tray for 800 x 1000 (grey) 		1-3 7537673 	                                                                       CRAC systems, useful cooling output 18 - 118kW
     TS 8 four-way fan tray for 600 x 1000 (black) 		1-3 7537347 	                                                                      The CRAC system draws warm waste air from the top of your Data Centre, cools it either with water or refrigerant
     TS 8 four-way fan tray for 800 x 1000 (black) 		1-3 7537346 	                                                                      in a closed heat exchanger, and blows the cooled, filtered supply air into the raised floor with overpressure.


    IT Chillers
    Especially for cooling IT applications, such as LCP or air/water heat exchangers.
                                                                                                                                        	The unit is available in a broad output range, and for a variety of cooling media.
    Safety-relevant features such as redundant speed-controlled pumps, compressors
                                                                                                                                        	The unit supports optimum integration of both hardware and software.
    or buffer stores are the distinguishing features of these atmospherically sealed systems.
                                                                                                                                        	Optimum energy and space efficiency thanks to intelligent design features,
    	Compact design with control components in the front and air intake via both                                                       	 such as the slanted heat exchanger and base-integrated fan.
    	 side panels, air outlet upwards.                                                                                                  	Frame based on the popular TS 8 system.
    	Pressure-sealed system.
    	 igital thermostat for temperature control with setpoint and actual value display.
        D                                                                                                                               Model No. SK 	           Without heater 	            3301620 	    3301660 	   3301830 	    3301870 	 300510 	 3300560 	        3300710 	       3300760
    	 onitoring interface with Rittal CMC-TC supported.
        M                                                                                                                               Model No. SK 	           With heater 	               3301630 	    3301670 	   3301840 	    3301880 	 3300520 	 3300570 	       3300720 	       3300770
                                                                                                                                        Model No. SK 	           With dampening 	            3301640 	    3301680 	   3301850 	    3301890 	 3300530 	 3300580 	       3300730 	       3300780
    	ntegral automatic bypass valve.
        I                                                                                                                               Model No. SK 	           With heater	                3301650 	    3301690 	   3301860 	    3301990 	 3300540 	 3300590 	       3300740 	       3300790
    	Flow monitor.                                                                                                                    	                        and dampening
                                                                                                                                        Useful cooling output1) 		                            23 kW 	  39 kW 	  78 kW 	  118 kW 	 18 kW 	  30 kW 	  43 kW 	  54 kW
                                                                                                                                        Operating voltage V/Hz 		                             400/50 	 400/50 	 400/50 	 400/50 	 400/50 	 400/50 	 400/50 	 400/50
    Please contact us for further information
                                                                                                                                        Dimensions mm		                        W               1100	    1100	    1800	    2600	    1100	    1100	    1400	    1800
                                                                                                                                        		                                     H               1950	1950	1950	 1950	 1950	 1950	1950	1950
                                                                                                                                        		                                     D               650	850	850	 850	 850	 850	850	850

                                                                                                                                        Cooling medium 	                                     Water2) 	                                               Refrigerant R407C2)
                                                                                                                                        Volumetric airflow at an external pressure loss 	   6000 m3/h 	 11000 m3/h 	 22000 m3/h 	33000 m3/h 	   6000 m3/h 8500 m3/h 12500 m3/h 16000 m3/h
                                                                                                                                        of 20 Pa
LCP Passive Up to 20kW Cooling                                                                                                          No. of fans 	                                       1	           1	           2	          3	            1	          1	          1	         2
                                                                                                                                        Power consumption of fans 	                         0.6 kW 	     1.5 kW 	     3.0 kW 	    4.6 kW 	      0.6 kW 	    0.9 kW 	    1.8 kW 	 1.7 kW
                                                                                                                                        Start-up current of fans 	                          1.8 A 	      4.6 A 	      9.2 A 	     13.8 A 	      1.8 A 	     4.6 A 	     4.6 A 	 9.2 A
To support existing air-conditioning systems, Rittal is now offering liquid based cooling
                                                                                                                                        Max. speed 	                                        1150 rpm 	 1200 rpm 	 1200 rpm 	 1200 rpm 	         1150 rpm 	 1200 rpm 	 1200 rpm 	1200 rpm
systems for retrofitting on server racks. The new LCP (Liquid Cooling Package) unit is based                                            No. of compressors 	                                – 				                                              1	         2	         3	      3
on an air/water heat exchanger technology and solves the problem of high heat losses of up                                              Power consumption of compressors 	                  – 				                                              5 kW 	      8.8 kW 	    13.1 kW 	 15 kW
                                                                                                                                        Start-up current of compressors 	                   – 				                                              13.1 A 	    25.6 A 	    38.4 A 		 39.3 A
to per rack. Without having to modify existing series of racks, the innovation can be attached
                                                                                                                                        Type of connection 	                                Terminal strip 			                                  –
as an independent cooling unit to the rear doors of practically any rack - and while the rack is                                        Weight 	                                            300 kg 	     360 kg 	     550 kg 	    770 kg 	      455 kg 	    505 kg 	    585 kg 	 935 kg
in operation. The hot air, dissipated towards the rear by the servers, is forced through the air/                                       Noise output 	                                      75 dB (A) 	 79 dB (A) 	 82 dB (A) 	 84 dB (A) 	     74 dB (A) 	 74 dB (A) 	 81 dB (A) 	 76 dB (A)
                                                                                                                                        Filter quality to DIN EN 779 	                      G4 				                                             G4
water heat exchanger by fan units and then expelled. However, connection to a circulatory
cooling-water supply is necessary before the LCP unit can be installed.
                                                                                                                                        1) Output figures less heat from the fans. CW: 26°C/45 % air inlet and 10°C/15°C water temperatures DX: 26°C/45 % air inlet and 50°C condensation temperature.
	      Useful cooling output	                    Description 	               Model No.                                                  2) Other media available on request. Other options available on request. We reserve the right to make technical modifications.
	           Up to 12kW	                           LCP Extend	3311600




section09 - 53                                                     Rittal IT-Power, Cooling  The Enviroment 2011                        Rittal IT-Power, Cooling  The Enviroment 2011                                                                                                          section09 - 54
What is best, Hot or Cold Aisle Containment?
                                                                                                                                                                    In short both systems do the same thing, they both raise

Cooling                                                                                                                                                             the return temperature to the cooling system, whether that
                                                                                                                                                                    is CRACs or Inline cooling. Therefore it is the application
                                                                                                                                                                    that decides which is best.
Rittal Aisle Containment System                                                                                                                                     Cold Aisle Containment Key Points


                                                                                                                                                                     	Contains the cold air within the aisle
Aisle Containment overview                                                                                                                                           	Increases cooling capacity to 10 kW+ per rack
The Rittal Aisle Containment System is increasingly being deployed in Data Centres where the average power demand of each                                            	Can either use CRACS or Inline cooling
cabinet exceeds 5kW. Effectively using roof panels and slideable doors at each end of the row which ‘contains’ the air within                                        	Retrofittable in most cases (uses existing CRACS)
the aisle. This prevents the cold and the hot air mixing which increases the capacity of the overall system to approx                                                	Takes up less space than HACs (not Inline cooling)
10 kW per cabinet. The other benefit is that because the cold air is now being delivered directly to the server, the cold aisle air
temperature can be raised, this means the CRAC or Inline cooling (LCP Inline) system is a lot more energy efficient which
results in long-term energy cost savings.
                                                                                                                                                                    Hot Aisle Containment Key Points
 	Cold and hot air cannot mix, warm air does not flow into the cold aisle
 	The system can be operated with a much higher extracted air temperature.                                                                                          	Contains the hot air within the aisle
 	Standard air circulation cooling units are operated at an optimum thermal efficency level                                                                         	Increases cooling capacity to 10 kW+ per rack
                                                                                                                                                                     Predominately uses Inline cooling
Key Components for Aisle Containment                                                                                                                                 	Can use CRACS but needs a hot air plenum
The key components of containment (same for both hot aisle and cold aisle) system are very simple. Firstly you need to specify                                       	Non 19” equipment can reside in the cold aisle
the containment dimensions and secondly the cooling system required.


The containment system is made up of roof panels and end doors. The roof panels bridge across the aisle between the racks
and the aisle and doors then close off the aisle. The roof sections are specified on the width of the aisle and the width
of the rack that they need to be secured to. The end doors quite simply match the height of the rack.


The cooling system for cold aisle and hot aisle can either be CRAC or Inline cooling, both have their advantages and limitations.
With the focus on efficiency and energy savings, we recommend you to contact our specialist sales team to
specify and advise the best cooling solution not only for your application but also for your long term business needs.


Please contact us for a quotation.




section09 - 55                                                                              Rittal IT-Power, Cooling  The Enviroment 2011   Rittal IT-Power, Cooling  The Enviroment 2011                                       section09 - 56
18 mm
                                                                                    Cooling
                                                                                                                        USA


Rittal Liquid Cooling Package - Pefect cooling four times over

LCP Inline - Up to 60kW of cooling

In conjunction with the new LCP Inine, cold aisle containment is an enhanced option for the
efficient dissipation of high heat loads from server enclosures. With up to 60 kW per module


                                                                                                                                         Monitoring and Security
the LCP Inline integrates directly into the aisle containment and delivers cold air directly into
the aisle. It can be either used as a replacement to the CRAC system or as an assistance
for greater cooling capacity. With integration into the network, LCP Inline provides real time
update of the status of the cooling system. With SNMP protocol included LCP Inline links
directly with your NMS system to provide an additional holistic overview.
                                                                                                                                         Section 10
                                                                                                                        83 mm
Design		CW	                                                           CW
Cooling medium		                    Water (for specifications see Internet)
Model No. SK		                      3311.530	                          3311.560	
Rated operating voltage V, Hz		     230, 1~, 50/60	                    230, 1~, 50/60
		                                  400, 3~, 50/60	                    400, 3~, 50/60
Dimensions mm	       W x H x D	     300 x 2000 x 1200	                300 x 2000 x 1200
Usable U		                          42	                               42
Useful cooling output		             Up to 30 kW	                      Up to 60 kW	



LCP Inline - Up to 60kW of cooling
The LCP Inline is designed for siting within a bayed enclosure at the rear of the device and
expelled at the front into the suite. The hot air is drawn in from the room or hot aisle room or
cold aisle after cooling.

Design		                             CW	                      CW 	                      CW
Cooling medium		                     Water (for specifications see Internet)
Model No. SK		                       3311.130	                 3311.230	                3311.260	
Rated operating voltage V, Hz		      230, 1~, 50/60	           230, 1~, 50/60	          230, 1~, 50/60
		                                   400, 3~, 50/60	           400, 3~, 50/60	          400, 3~, 50/60
Dimensions mm	       W x H x D	      300 x 2000 x 1000	       300 x 2000 x 1200	        300 x 2000 x 1200
Usable U		                           42	                      42	                       42
Useful cooling output		              Up to 30 kW	             Up to 30 kW	              Up to 60 kW




LCP T3+ - Up to 24kW of Cooling N+1
The heart of the new LCP T3+ system is a heat exchanger unit comprising two fully integrated
cooling circuits and implementing an intelligent controller concept. This further development
does away with all disturbance-prone air baffle systems and ensures cooling of the whole air
flow. This sophisticated design guarantees maximum availability, even if the one circuit is put                                	        CMC Standard
out of action, because each of the two cooling circuits is able to uphold the full nominal                                     	        CyberLock
cooling capacity of the system. The power supply, too, is configured with two active paths
                                                                                                                        236 mm 	        Fire Detection
and is maintained at all times thanks to the standard integration of a transfer switch. In case                                	        Mini Data Centre
of a power infeed failure, the supply is switched automatically to the second infeed within                                    	        Modular Rooms
fractions of a second, with no interruption to operation.

	    Useful cooling output	                 Description 	                Model No.
	          Up to 24kW	                        LCP T3+	3300239




section09 - 57                                                 Rittal IT-Power, Cooling  The Enviroment 2011                 Rittal IT-Power, Cooling  The Enviroment 2011   section10 - 58
                                                                                                                        USA

More Related Content

What's hot

GE Jebachers Gas Engine JGS620 technical specifications
GE Jebachers Gas Engine JGS620 technical specificationsGE Jebachers Gas Engine JGS620 technical specifications
GE Jebachers Gas Engine JGS620 technical specificationsMuhammad Asif Siddiqui
 
Sp1656 1324 kw uk perkins generator data sheet
Sp1656 1324 kw uk perkins generator data sheetSp1656 1324 kw uk perkins generator data sheet
Sp1656 1324 kw uk perkins generator data sheetSUNSHINE MACHINERY
 
500kva Uk Perkins generator sets With Leroy Somer Data Sheet
500kva Uk Perkins generator sets With Leroy Somer Data Sheet500kva Uk Perkins generator sets With Leroy Somer Data Sheet
500kva Uk Perkins generator sets With Leroy Somer Data SheetSUNSHINE MACHINERY
 
Sc150 cummins generation Groupe électrogène, Plantas Eléctricas,
Sc150 cummins generation Groupe électrogène, Plantas Eléctricas,Sc150 cummins generation Groupe électrogène, Plantas Eléctricas,
Sc150 cummins generation Groupe électrogène, Plantas Eléctricas,SUNSHINE MACHINERY
 
Sd150 Deutz generator Data Sheet S
Sd150 Deutz generator Data Sheet SSd150 Deutz generator Data Sheet S
Sd150 Deutz generator Data Sheet SSUNSHINE MACHINERY
 
DAIKIN VRV PIPE SELECTION CHART
DAIKIN VRV PIPE SELECTION CHARTDAIKIN VRV PIPE SELECTION CHART
DAIKIN VRV PIPE SELECTION CHARTquaseem akhter
 
Doosan diesel generator Data Sheet
Doosan diesel generator Data SheetDoosan diesel generator Data Sheet
Doosan diesel generator Data SheetSUNSHINE MACHINERY
 
Specification – Perkins UK Generating Set – Dubai
Specification – Perkins UK Generating Set – DubaiSpecification – Perkins UK Generating Set – Dubai
Specification – Perkins UK Generating Set – DubaiAdpower FZCO
 

What's hot (16)

GE Jebachers Gas Engine JGS620 technical specifications
GE Jebachers Gas Engine JGS620 technical specificationsGE Jebachers Gas Engine JGS620 technical specifications
GE Jebachers Gas Engine JGS620 technical specifications
 
Sp1656 1324 kw uk perkins generator data sheet
Sp1656 1324 kw uk perkins generator data sheetSp1656 1324 kw uk perkins generator data sheet
Sp1656 1324 kw uk perkins generator data sheet
 
500kva Uk Perkins generator sets With Leroy Somer Data Sheet
500kva Uk Perkins generator sets With Leroy Somer Data Sheet500kva Uk Perkins generator sets With Leroy Somer Data Sheet
500kva Uk Perkins generator sets With Leroy Somer Data Sheet
 
Sc150 cummins generation Groupe électrogène, Plantas Eléctricas,
Sc150 cummins generation Groupe électrogène, Plantas Eléctricas,Sc150 cummins generation Groupe électrogène, Plantas Eléctricas,
Sc150 cummins generation Groupe électrogène, Plantas Eléctricas,
 
G y un50_00
G y un50_00G y un50_00
G y un50_00
 
Sp2000
Sp2000Sp2000
Sp2000
 
Sd150 Deutz generator Data Sheet S
Sd150 Deutz generator Data Sheet SSd150 Deutz generator Data Sheet S
Sd150 Deutz generator Data Sheet S
 
Unico System for Commercial HVAC Promotional Flyer
Unico System for Commercial HVAC Promotional FlyerUnico System for Commercial HVAC Promotional Flyer
Unico System for Commercial HVAC Promotional Flyer
 
60 sp440
60 sp44060 sp440
60 sp440
 
Sp33 data sheet
Sp33 data sheetSp33 data sheet
Sp33 data sheet
 
60 sp928
60 sp92860 sp928
60 sp928
 
Unico Residential HVAC System Installation Guide
Unico Residential HVAC System Installation Guide Unico Residential HVAC System Installation Guide
Unico Residential HVAC System Installation Guide
 
Sc413 cummins
Sc413 cumminsSc413 cummins
Sc413 cummins
 
DAIKIN VRV PIPE SELECTION CHART
DAIKIN VRV PIPE SELECTION CHARTDAIKIN VRV PIPE SELECTION CHART
DAIKIN VRV PIPE SELECTION CHART
 
Doosan diesel generator Data Sheet
Doosan diesel generator Data SheetDoosan diesel generator Data Sheet
Doosan diesel generator Data Sheet
 
Specification – Perkins UK Generating Set – Dubai
Specification – Perkins UK Generating Set – DubaiSpecification – Perkins UK Generating Set – Dubai
Specification – Perkins UK Generating Set – Dubai
 

Viewers also liked

Piante officinali in Italia: struttura delle imprese secondo il punto di vist...
Piante officinali in Italia: struttura delle imprese secondo il punto di vist...Piante officinali in Italia: struttura delle imprese secondo il punto di vist...
Piante officinali in Italia: struttura delle imprese secondo il punto di vist...Andrea Primavera
 
こだわり:自分にオススメするこだわりランキング!!
こだわり:自分にオススメするこだわりランキング!!こだわり:自分にオススメするこだわりランキング!!
こだわり:自分にオススメするこだわりランキング!!sasapyon3
 
UN SLIDE
UN SLIDEUN SLIDE
UN SLIDEkth411
 

Viewers also liked (7)

Piante officinali in Italia: struttura delle imprese secondo il punto di vist...
Piante officinali in Italia: struttura delle imprese secondo il punto di vist...Piante officinali in Italia: struttura delle imprese secondo il punto di vist...
Piante officinali in Italia: struttura delle imprese secondo il punto di vist...
 
こだわり:自分にオススメするこだわりランキング!!
こだわり:自分にオススメするこだわりランキング!!こだわり:自分にオススメするこだわりランキング!!
こだわり:自分にオススメするこだわりランキング!!
 
UN SLIDE
UN SLIDEUN SLIDE
UN SLIDE
 
Four activities by singaraj
Four activities by singarajFour activities by singaraj
Four activities by singaraj
 
Earth
EarthEarth
Earth
 
Snug Harbour Mixed Use Project
Snug Harbour Mixed Use ProjectSnug Harbour Mixed Use Project
Snug Harbour Mixed Use Project
 
SAP MII
SAP MIISAP MII
SAP MII
 

Similar to Section Nine Rittal4racks 2012

Sb ls screw-fixed-speed_ver.3.0_en
Sb ls screw-fixed-speed_ver.3.0_enSb ls screw-fixed-speed_ver.3.0_en
Sb ls screw-fixed-speed_ver.3.0_enYury Naumov
 
Rittal top therm_chiller
Rittal top therm_chillerRittal top therm_chiller
Rittal top therm_chillerEeu SC
 
Sb ls scroll-uc_ver.3.0_en
Sb ls scroll-uc_ver.3.0_enSb ls scroll-uc_ver.3.0_en
Sb ls scroll-uc_ver.3.0_enYury Naumov
 
Sb ls screw-inverter_ver.3.0_en
Sb ls screw-inverter_ver.3.0_enSb ls screw-inverter_ver.3.0_en
Sb ls screw-inverter_ver.3.0_enYury Naumov
 
Sb ls scroll_ver.3.0_en
Sb ls scroll_ver.3.0_enSb ls scroll_ver.3.0_en
Sb ls scroll_ver.3.0_enYury Naumov
 
Blue 'e' leaflet
Blue 'e' leafletBlue 'e' leaflet
Blue 'e' leafletSindhu Rao
 
Sb ls freecool-screw-inverter_1.2_en
Sb ls freecool-screw-inverter_1.2_enSb ls freecool-screw-inverter_1.2_en
Sb ls freecool-screw-inverter_1.2_enYury Naumov
 
Powerstream Turbo chiller
Powerstream Turbo chillerPowerstream Turbo chiller
Powerstream Turbo chillerKaltra_DE
 
Boge screw air compressors--oil free solutions
Boge screw air compressors--oil free solutionsBoge screw air compressors--oil free solutions
Boge screw air compressors--oil free solutionsdaisy Airmax
 
Crac precision climate_control_units_for_data_centres
Crac precision climate_control_units_for_data_centresCrac precision climate_control_units_for_data_centres
Crac precision climate_control_units_for_data_centresEeu SC
 
Dc inverter heat pump blueway
Dc inverter heat pump bluewayDc inverter heat pump blueway
Dc inverter heat pump bluewayRoger Luo
 
Dry Coolers - liquid coolers by Thermokey
Dry Coolers - liquid coolers  by ThermokeyDry Coolers - liquid coolers  by Thermokey
Dry Coolers - liquid coolers by ThermokeyGiuseppe Visentini
 
Sb easystream ver.2.0_en
Sb easystream ver.2.0_enSb easystream ver.2.0_en
Sb easystream ver.2.0_enYury Naumov
 
Rittal Pano Isıtıcıları
Rittal Pano IsıtıcılarıRittal Pano Isıtıcıları
Rittal Pano Isıtıcılarıerdinc klima
 
Sb delta dx-dc-ver.4.0_en
Sb delta dx-dc-ver.4.0_enSb delta dx-dc-ver.4.0_en
Sb delta dx-dc-ver.4.0_enYury Naumov
 

Similar to Section Nine Rittal4racks 2012 (20)

Sb ls screw-fixed-speed_ver.3.0_en
Sb ls screw-fixed-speed_ver.3.0_enSb ls screw-fixed-speed_ver.3.0_en
Sb ls screw-fixed-speed_ver.3.0_en
 
Rittal top therm_chiller
Rittal top therm_chillerRittal top therm_chiller
Rittal top therm_chiller
 
Sb ls scroll-uc_ver.3.0_en
Sb ls scroll-uc_ver.3.0_enSb ls scroll-uc_ver.3.0_en
Sb ls scroll-uc_ver.3.0_en
 
Sb ls screw-inverter_ver.3.0_en
Sb ls screw-inverter_ver.3.0_enSb ls screw-inverter_ver.3.0_en
Sb ls screw-inverter_ver.3.0_en
 
Sb ls scroll_ver.3.0_en
Sb ls scroll_ver.3.0_enSb ls scroll_ver.3.0_en
Sb ls scroll_ver.3.0_en
 
Blue 'e' leaflet
Blue 'e' leafletBlue 'e' leaflet
Blue 'e' leaflet
 
Sb ls freecool-screw-inverter_1.2_en
Sb ls freecool-screw-inverter_1.2_enSb ls freecool-screw-inverter_1.2_en
Sb ls freecool-screw-inverter_1.2_en
 
Powerstream Turbo chiller
Powerstream Turbo chillerPowerstream Turbo chiller
Powerstream Turbo chiller
 
Breezair tbs580
Breezair tbs580 Breezair tbs580
Breezair tbs580
 
Dekon Rooftop units t3 conditions
Dekon Rooftop units t3 conditions Dekon Rooftop units t3 conditions
Dekon Rooftop units t3 conditions
 
Nlc co y-na60_02
Nlc co y-na60_02Nlc co y-na60_02
Nlc co y-na60_02
 
Boge screw air compressors--oil free solutions
Boge screw air compressors--oil free solutionsBoge screw air compressors--oil free solutions
Boge screw air compressors--oil free solutions
 
Crac precision climate_control_units_for_data_centres
Crac precision climate_control_units_for_data_centresCrac precision climate_control_units_for_data_centres
Crac precision climate_control_units_for_data_centres
 
Carrier Aspire Brochure
Carrier Aspire BrochureCarrier Aspire Brochure
Carrier Aspire Brochure
 
Dc inverter heat pump blueway
Dc inverter heat pump bluewayDc inverter heat pump blueway
Dc inverter heat pump blueway
 
Wrl hp y-na60_00
Wrl hp y-na60_00Wrl hp y-na60_00
Wrl hp y-na60_00
 
Dry Coolers - liquid coolers by Thermokey
Dry Coolers - liquid coolers  by ThermokeyDry Coolers - liquid coolers  by Thermokey
Dry Coolers - liquid coolers by Thermokey
 
Sb easystream ver.2.0_en
Sb easystream ver.2.0_enSb easystream ver.2.0_en
Sb easystream ver.2.0_en
 
Rittal Pano Isıtıcıları
Rittal Pano IsıtıcılarıRittal Pano Isıtıcıları
Rittal Pano Isıtıcıları
 
Sb delta dx-dc-ver.4.0_en
Sb delta dx-dc-ver.4.0_enSb delta dx-dc-ver.4.0_en
Sb delta dx-dc-ver.4.0_en
 

More from iTECHbyNBM - A Division of NBM Distribution Ltd (6)

NBM Distribution Ltd 2012 Catalogue
NBM Distribution Ltd 2012 CatalogueNBM Distribution Ltd 2012 Catalogue
NBM Distribution Ltd 2012 Catalogue
 
NBM Distribution Ltd Presentation
NBM Distribution Ltd PresentationNBM Distribution Ltd Presentation
NBM Distribution Ltd Presentation
 
NBM Company profile Information
NBM Company profile InformationNBM Company profile Information
NBM Company profile Information
 
Brand Rex Environmental Brochure Web
Brand Rex Environmental Brochure WebBrand Rex Environmental Brochure Web
Brand Rex Environmental Brochure Web
 
6 Zone Overview Compatibility Mode
6 Zone Overview Compatibility Mode6 Zone Overview Compatibility Mode
6 Zone Overview Compatibility Mode
 
Unite Technologies Ltd Presentation
Unite Technologies Ltd   PresentationUnite Technologies Ltd   Presentation
Unite Technologies Ltd Presentation
 

Section Nine Rittal4racks 2012

  • 1. Cooling Rittal Cooling Application Guide CRAC and Chiller Systems up to 118 kW IT chillers and CRACs in conjunction with freecooling ensure efficient cooling and supply of the cooling medium. Safety-relevant options such as redundant pumps, emergency cooling and buffer stores ensure maximum operational reliability and fail-safeness. LCP T3+ Maximum reliability with redundant cooling and power up to 24 kW At the heart of the LCP T3+ are two embedded cold water circuits, each of which supplies 100% of the nominal cooling output. The power supply to the fans also has a completely redundant layout. LCP Plus - High density rack cooling up to 30 kW Air/water heat exchanger, bayable with server racks based on TS 8. Complete unit with 30 kW useful cooling output. The separation of cooling and rack prevents the ingress of water into the server rack, making it easy to assemble and very service-friendly. LCP Inline - Modular Liquid cooling up to 60 kW Based on the LCP Plus design the air is delivered directly into the cold aisle rather than the rack. With superior resilience modularity it is a perfect cooling method for cold aisle and hot aisle containment systems. Vertical ventilation up to 3 kW Ventilation base/plinth, roof vent and slotted component shelves ensure effective heat dissipation. Horizontal ventilation up to 5 kW A high air throughput, stylish design and outstanding security are provided by the perforated doors (with 82% open area per door). Hot Aisle Containment up to 10 kW Separates the hot air from the cold. Utilising in line coolers the hot air is extracted and cooled to provide cold air to the front of the server. Cold Aisle Containment up to 10 kW Traps the incoming cold air in front of the server inlets. Can either use inline cooling or CRACs to provide the cold air. LCP Passive Retro-fittable cooling up to 20 kW Perfect for dealing with any hot spots with in the Data Centre section09 - 51 Rittal IT-Power, Cooling & The Enviroment 2011 Rittal IT-Power, Cooling & The Enviroment 2011 section09 - 52
  • 2. Cooling Cooling Fan Trays When an excessive build up of heat occurs, fan trays are an excellent way to remove the warm air from the racks. All Rittal fan trays can be fitted during configuration or alternatively retro-fitted without any TS 8 Top Fan Tray disruption to the equipment within the rack. Description Model No. 2-way 19” Rack mounted fan tray 1 U 1-3 7027504 TE 7000 four-way top mounted fan tray 1-3 7001001 TS 8 four-way fan tray for 800 x 800 and 600 x 1000 (grey) 1-3 7537671 TS 8 four-way fan tray for 600 x 600, 600 x 800 and 800 x 600 (grey) 1-3 7537670 TS 8 four-way fan tray for 800 x 1000 (grey) 1-3 7537673 CRAC systems, useful cooling output 18 - 118kW TS 8 four-way fan tray for 600 x 1000 (black) 1-3 7537347 The CRAC system draws warm waste air from the top of your Data Centre, cools it either with water or refrigerant TS 8 four-way fan tray for 800 x 1000 (black) 1-3 7537346 in a closed heat exchanger, and blows the cooled, filtered supply air into the raised floor with overpressure. IT Chillers Especially for cooling IT applications, such as LCP or air/water heat exchangers.  The unit is available in a broad output range, and for a variety of cooling media. Safety-relevant features such as redundant speed-controlled pumps, compressors  The unit supports optimum integration of both hardware and software. or buffer stores are the distinguishing features of these atmospherically sealed systems.  Optimum energy and space efficiency thanks to intelligent design features,  Compact design with control components in the front and air intake via both such as the slanted heat exchanger and base-integrated fan. side panels, air outlet upwards.  Frame based on the popular TS 8 system.  Pressure-sealed system.  igital thermostat for temperature control with setpoint and actual value display. D Model No. SK Without heater 3301620 3301660 3301830 3301870 300510 3300560 3300710 3300760  onitoring interface with Rittal CMC-TC supported. M Model No. SK With heater 3301630 3301670 3301840 3301880 3300520 3300570 3300720 3300770 Model No. SK With dampening 3301640 3301680 3301850 3301890 3300530 3300580 3300730 3300780  ntegral automatic bypass valve. I Model No. SK With heater 3301650 3301690 3301860 3301990 3300540 3300590 3300740 3300790  Flow monitor. and dampening Useful cooling output1) 23 kW 39 kW 78 kW 118 kW 18 kW 30 kW 43 kW 54 kW Operating voltage V/Hz 400/50 400/50 400/50 400/50 400/50 400/50 400/50 400/50 Please contact us for further information Dimensions mm W 1100 1100 1800 2600 1100 1100 1400 1800 H 1950 1950 1950 1950 1950 1950 1950 1950 D 650 850 850 850 850 850 850 850 Cooling medium Water2) Refrigerant R407C2) Volumetric airflow at an external pressure loss 6000 m3/h 11000 m3/h 22000 m3/h 33000 m3/h 6000 m3/h 8500 m3/h 12500 m3/h 16000 m3/h of 20 Pa LCP Passive Up to 20kW Cooling No. of fans 1 1 2 3 1 1 1 2 Power consumption of fans 0.6 kW 1.5 kW 3.0 kW 4.6 kW 0.6 kW 0.9 kW 1.8 kW 1.7 kW Start-up current of fans 1.8 A 4.6 A 9.2 A 13.8 A 1.8 A 4.6 A 4.6 A 9.2 A To support existing air-conditioning systems, Rittal is now offering liquid based cooling Max. speed 1150 rpm 1200 rpm 1200 rpm 1200 rpm 1150 rpm 1200 rpm 1200 rpm 1200 rpm systems for retrofitting on server racks. The new LCP (Liquid Cooling Package) unit is based No. of compressors – 1 2 3 3 on an air/water heat exchanger technology and solves the problem of high heat losses of up Power consumption of compressors – 5 kW 8.8 kW 13.1 kW 15 kW Start-up current of compressors – 13.1 A 25.6 A 38.4 A 39.3 A to per rack. Without having to modify existing series of racks, the innovation can be attached Type of connection Terminal strip – as an independent cooling unit to the rear doors of practically any rack - and while the rack is Weight 300 kg 360 kg 550 kg 770 kg 455 kg 505 kg 585 kg 935 kg in operation. The hot air, dissipated towards the rear by the servers, is forced through the air/ Noise output 75 dB (A) 79 dB (A) 82 dB (A) 84 dB (A) 74 dB (A) 74 dB (A) 81 dB (A) 76 dB (A) Filter quality to DIN EN 779 G4 G4 water heat exchanger by fan units and then expelled. However, connection to a circulatory cooling-water supply is necessary before the LCP unit can be installed. 1) Output figures less heat from the fans. CW: 26°C/45 % air inlet and 10°C/15°C water temperatures DX: 26°C/45 % air inlet and 50°C condensation temperature. Useful cooling output Description Model No. 2) Other media available on request. Other options available on request. We reserve the right to make technical modifications. Up to 12kW LCP Extend 3311600 section09 - 53 Rittal IT-Power, Cooling The Enviroment 2011 Rittal IT-Power, Cooling The Enviroment 2011 section09 - 54
  • 3. What is best, Hot or Cold Aisle Containment? In short both systems do the same thing, they both raise Cooling the return temperature to the cooling system, whether that is CRACs or Inline cooling. Therefore it is the application that decides which is best. Rittal Aisle Containment System Cold Aisle Containment Key Points  Contains the cold air within the aisle Aisle Containment overview  Increases cooling capacity to 10 kW+ per rack The Rittal Aisle Containment System is increasingly being deployed in Data Centres where the average power demand of each  Can either use CRACS or Inline cooling cabinet exceeds 5kW. Effectively using roof panels and slideable doors at each end of the row which ‘contains’ the air within  Retrofittable in most cases (uses existing CRACS) the aisle. This prevents the cold and the hot air mixing which increases the capacity of the overall system to approx  Takes up less space than HACs (not Inline cooling) 10 kW per cabinet. The other benefit is that because the cold air is now being delivered directly to the server, the cold aisle air temperature can be raised, this means the CRAC or Inline cooling (LCP Inline) system is a lot more energy efficient which results in long-term energy cost savings. Hot Aisle Containment Key Points  Cold and hot air cannot mix, warm air does not flow into the cold aisle  The system can be operated with a much higher extracted air temperature.  Contains the hot air within the aisle  Standard air circulation cooling units are operated at an optimum thermal efficency level  Increases cooling capacity to 10 kW+ per rack  Predominately uses Inline cooling Key Components for Aisle Containment  Can use CRACS but needs a hot air plenum The key components of containment (same for both hot aisle and cold aisle) system are very simple. Firstly you need to specify  Non 19” equipment can reside in the cold aisle the containment dimensions and secondly the cooling system required. The containment system is made up of roof panels and end doors. The roof panels bridge across the aisle between the racks and the aisle and doors then close off the aisle. The roof sections are specified on the width of the aisle and the width of the rack that they need to be secured to. The end doors quite simply match the height of the rack. The cooling system for cold aisle and hot aisle can either be CRAC or Inline cooling, both have their advantages and limitations. With the focus on efficiency and energy savings, we recommend you to contact our specialist sales team to specify and advise the best cooling solution not only for your application but also for your long term business needs. Please contact us for a quotation. section09 - 55 Rittal IT-Power, Cooling The Enviroment 2011 Rittal IT-Power, Cooling The Enviroment 2011 section09 - 56
  • 4. 18 mm Cooling USA Rittal Liquid Cooling Package - Pefect cooling four times over LCP Inline - Up to 60kW of cooling In conjunction with the new LCP Inine, cold aisle containment is an enhanced option for the efficient dissipation of high heat loads from server enclosures. With up to 60 kW per module Monitoring and Security the LCP Inline integrates directly into the aisle containment and delivers cold air directly into the aisle. It can be either used as a replacement to the CRAC system or as an assistance for greater cooling capacity. With integration into the network, LCP Inline provides real time update of the status of the cooling system. With SNMP protocol included LCP Inline links directly with your NMS system to provide an additional holistic overview. Section 10 83 mm Design CW CW Cooling medium Water (for specifications see Internet) Model No. SK 3311.530 3311.560 Rated operating voltage V, Hz 230, 1~, 50/60 230, 1~, 50/60 400, 3~, 50/60 400, 3~, 50/60 Dimensions mm W x H x D 300 x 2000 x 1200 300 x 2000 x 1200 Usable U 42 42 Useful cooling output Up to 30 kW Up to 60 kW LCP Inline - Up to 60kW of cooling The LCP Inline is designed for siting within a bayed enclosure at the rear of the device and expelled at the front into the suite. The hot air is drawn in from the room or hot aisle room or cold aisle after cooling. Design CW CW CW Cooling medium Water (for specifications see Internet) Model No. SK 3311.130 3311.230 3311.260 Rated operating voltage V, Hz 230, 1~, 50/60 230, 1~, 50/60 230, 1~, 50/60 400, 3~, 50/60 400, 3~, 50/60 400, 3~, 50/60 Dimensions mm W x H x D 300 x 2000 x 1000 300 x 2000 x 1200 300 x 2000 x 1200 Usable U 42 42 42 Useful cooling output Up to 30 kW Up to 30 kW Up to 60 kW LCP T3+ - Up to 24kW of Cooling N+1 The heart of the new LCP T3+ system is a heat exchanger unit comprising two fully integrated cooling circuits and implementing an intelligent controller concept. This further development does away with all disturbance-prone air baffle systems and ensures cooling of the whole air flow. This sophisticated design guarantees maximum availability, even if the one circuit is put  CMC Standard out of action, because each of the two cooling circuits is able to uphold the full nominal  CyberLock cooling capacity of the system. The power supply, too, is configured with two active paths 236 mm  Fire Detection and is maintained at all times thanks to the standard integration of a transfer switch. In case  Mini Data Centre of a power infeed failure, the supply is switched automatically to the second infeed within  Modular Rooms fractions of a second, with no interruption to operation. Useful cooling output Description Model No. Up to 24kW LCP T3+ 3300239 section09 - 57 Rittal IT-Power, Cooling The Enviroment 2011 Rittal IT-Power, Cooling The Enviroment 2011 section10 - 58 USA